Skip to main content

Cassius Leaflet

Page 1

NEW

Roofing Solutions

Cassius Antique Slate

ÂŽ

New Generation Clay Tile Due to high customer demand for larger and more versatile roof tiles, we have redesigned the ever popular Cassius tile to give improved coverage, whilst at the same time reducing build costs. The New Cassius is now 9.5 tiles per sq metre, compared with 10.5 for the old tile. Â The new improved Cassius has all the same benefits as existing Cassius designed in the same colours with the same fittings available.

10%

LARGER


NEW Cassius: New Generation Clay Tile Roofing Solutions

Features and benefits:

n Easy to lay open gauge clay tile n Over 50% more cost effective than natural slate n More cost effective than fibre cement products n Large format design means competitive with thin leading edge products n Performs at pitches down to 22.5⁰

THE RANGE Antique Slate

TECHNICAL DATA Minimum roof pitch*

22.5°

Headlap (minimum)

75 mm

Headlap (maximum)

120 mm

Batten spacing at maximum gauge

343 mm

Batten spacing at minimum gauge

298 mm

Size of tile

418 x 335 mm

Covering capacity at maximum gauge

9.5 tiles per m2

Cover width

307 mm

Profile depth

16 mm

Hanging length

390mm

Weight as laid

39.0 kg per m2

Weight per 1000

4.1 tonnes

Weight per tile

4.1 kg

Weight per pallet (including pallet & packaging)

1.0 tonnes

Quantity per pallet

240

Battens per m

2.9 m

Batten size - up to 450 mm rafter centres

38 x 25mm

Batten size - up to 600 mm rafter centres

50 x 25mm

Nail size/type for tiles

45 x 3.35 mm aluminium ring shank clout head

Nail size/type for metal tile clips

55 x 3.35 mm aluminium ring shank clout head

2

Tuscan

Product specification is subject to change and will be updated accordingly. For projects where the rafters are below the minimum recommended roof pitch please contact Sandtoft Technical Services for advice. Rafter length restrictions apply at minimum roof pitch. Clay tiles are subject to small variations in size because of drying and firing shrinkage in the manufacturing process. Before deciding on the batten gauge and linear coverage, the roof tiles should inspect each batch of tiles to ensure that the correct minimum headlap and sidelap are achieved. For further guidance, download the New Cassius Installation Guide. Note: unless otherwise stated, data is based on the tiles laid at minimum headlap. Tile Fixing Sandtoft roof tiles must be laid and fixed to comply with BS 5534: the British Standard Code of practice for slating and tiling, and BS 8000: Part 6: the British Standard Code of practice for workmanship on building sites. To ensure compliance with these Standards we recommend that a calculated fixing specification be obtained using Sandtoft’s Fixing SPEC service. Alternatively, all tiles must be twice nailed and clipped. For further information go to Fixing SPEC at www.sandtoft.com or contact Sandtoft Technical Services on 0844 9395 999.

Sandtoft Roof Tiles Belton Rd Sandtoft Doncaster DN8 5SY

n Samples available on request n Must not be laid with old Cassius

T 0844 9395 900 F 0844 9395 950 sandtoftorders@wienerberger.com www.sandtoft.com www.wienerberger.com


Turn static files into dynamic content formats.

Create a flipbook
Cassius Leaflet by Wienerberger AG - Issuu