NEW
Roofing Solutions
Cassius Antique Slate
ÂŽ
New Generation Clay Tile Due to high customer demand for larger and more versatile roof tiles, we have redesigned the ever popular Cassius tile to give improved coverage, whilst at the same time reducing build costs. The New Cassius is now 9.5 tiles per sq metre, compared with 10.5 for the old tile. Â The new improved Cassius has all the same benefits as existing Cassius designed in the same colours with the same fittings available.
10%
LARGER
NEW Cassius: New Generation Clay Tile Roofing Solutions
Features and benefits:
n Easy to lay open gauge clay tile n Over 50% more cost effective than natural slate n More cost effective than fibre cement products n Large format design means competitive with thin leading edge products n Performs at pitches down to 22.5⁰
THE RANGE Antique Slate
TECHNICAL DATA Minimum roof pitch*
22.5°
Headlap (minimum)
75 mm
Headlap (maximum)
120 mm
Batten spacing at maximum gauge
343 mm
Batten spacing at minimum gauge
298 mm
Size of tile
418 x 335 mm
Covering capacity at maximum gauge
9.5 tiles per m2
Cover width
307 mm
Profile depth
16 mm
Hanging length
390mm
Weight as laid
39.0 kg per m2
Weight per 1000
4.1 tonnes
Weight per tile
4.1 kg
Weight per pallet (including pallet & packaging)
1.0 tonnes
Quantity per pallet
240
Battens per m
2.9 m
Batten size - up to 450 mm rafter centres
38 x 25mm
Batten size - up to 600 mm rafter centres
50 x 25mm
Nail size/type for tiles
45 x 3.35 mm aluminium ring shank clout head
Nail size/type for metal tile clips
55 x 3.35 mm aluminium ring shank clout head
2
Tuscan
Product specification is subject to change and will be updated accordingly. For projects where the rafters are below the minimum recommended roof pitch please contact Sandtoft Technical Services for advice. Rafter length restrictions apply at minimum roof pitch. Clay tiles are subject to small variations in size because of drying and firing shrinkage in the manufacturing process. Before deciding on the batten gauge and linear coverage, the roof tiles should inspect each batch of tiles to ensure that the correct minimum headlap and sidelap are achieved. For further guidance, download the New Cassius Installation Guide. Note: unless otherwise stated, data is based on the tiles laid at minimum headlap. Tile Fixing Sandtoft roof tiles must be laid and fixed to comply with BS 5534: the British Standard Code of practice for slating and tiling, and BS 8000: Part 6: the British Standard Code of practice for workmanship on building sites. To ensure compliance with these Standards we recommend that a calculated fixing specification be obtained using Sandtoft’s Fixing SPEC service. Alternatively, all tiles must be twice nailed and clipped. For further information go to Fixing SPEC at www.sandtoft.com or contact Sandtoft Technical Services on 0844 9395 999.
Sandtoft Roof Tiles Belton Rd Sandtoft Doncaster DN8 5SY
n Samples available on request n Must not be laid with old Cassius
T 0844 9395 900 F 0844 9395 950 sandtoftorders@wienerberger.com www.sandtoft.com www.wienerberger.com