Skip to main content

foxcore 316l-t1

Page 1

FOXcore 316L-T1 Flux-cored wire, high-alloyed, austenitic stainless

Classifications EN ISO 17633-A

EN ISO 17633-B

AWS A5.22 / SFA-5.22

T 19 12 3 L P M21 (C1) 1

TS 316L-F M21 (C1) 0

E316LT1-4(1)

Characteristics and typical fields of application Rutile flux-cored wire of T 19 12 3 L P / E316LT1 type designed for welding 1.4404, 1.4432 / 316L type stainless steels with good resistance to general, pitting and intergranular corrosion in chloride containing environments. Intended for severe service conditions, e.g. in dilute hot acids. Also suitable for welding steels that are stabilized with titanium or niobium, such as 1.4571 / 316Ti for service temperatures not exceeding 400ºC. For higher temperatures a niobium-stabilized consumable such as FOXcore 318-T1 is required. The scaling temperature is approximately 850ºC in air. Designed for all-round welding and can be used in all positions without changing the parameter settings. Very good slag detachability and almost no spatter formation. Due to the fast freezing rutile slag, the weldability is excellent also in the vertical-up and overhead positions. The wide arc ensures even penetration and side-wall fusion to prevent lack of fusion. Suitable for service temperatures from –120ºC to 400ºC. For flat and horizontal welding positions, FOXcore 316L-T0 DG may be preferred.

Base materials 1.4401 X5CrNiMo17-12-2, 1.4404 X2CrNiMo17-12-2, 1.4409 GX2CrNiMo19-11-2, 1.4429 X2CrNiMoN17-12-3 1.4432 X2CrNiMo17-12-3, 1.4435 X2CrNiMo18-14-3, 1.4436 X3CrNiMo17-12-3, 1.4571 X6CrNiMoTi17-12-2 1.4580 X6CrNiMoNb17-12-2, 1.4583 X10CrNiMoNb18-12 UNS S31600, S31603, S31635, S31640, S31653 AISI 316L, 316Ti, 316Cb

Typical analysis wt.-%

C

Si

Mn

Cr

Ni

Mo

FN

0.03

0.7

1.5

19.0

12.0

2.7

4 – 13

Mechanical properties of all-weld metal - typical values (min. values) Condition

Yield strength Rp0.2

Tensile strength Rm

Elongation A (L0=5d0)

MPa

MPa

%

20°C

–20°C

–120°C

HB

u

410 (≥ 320)

550 (≥ 510)

34 (≥ 30)

65

55

40 (≥ 32)

210

Impact energy ISO-V KV J

Hardness

u untreated, as-welded – shielding gas M21 (Ar + 18% CO2)

Operating data Polarity

DC +

Dimension mm

Current A

Shielding gas (EN ISO 14175)

M21, (C1)

0.9

100-160

1.2

150-250

1.6

200-350

Welding with standard GMAW power source with DC+ polarity. No pulsing needed. Backhand (drag) technique preferred with a work angle of approximately 80º. Ar + 15 – 25% CO2 as shielding gas offers the best weldability. 100% CO2 can be also used, but the voltage should be increased by 2 V. Suitable gas flow rate is 15 – 18 l/min. The heat input should not exceed 2.0 kJ/mm, the interpass temperature be limited to max. 150ºC and the wire stick-out 15 – 20 mm. Post-weld heat treatment generally not needed. In special cases, solution annealing can be performed at 1050ºC followed by water quenching.

Approvals TÜV (09118), DB (43.014.24), ABS, BV (M21 + Ø 1.2 mm), CWB, DNV GL, LR (M21), CE

All information provided is based upon careful investigation and intensive research. However, we do not assume any liability for correctness and information is subject to change without notice.

1 / 1 02/2021 www.voestalpine.com/welding