LOWER MONUMENTAL DAM FISH LADDER TEMPERATURE CONTROL SYSTEM Project Team: Lauren Moore, Theodore Ertel, Madelynn Gregoire, Jayr Ayala Project Sponsors: Jarrod Milligan, S.E., Ryan Laughery, P.E. BACKGROUND Anadromous fish are deterred from exiting the Lower Monumental Dam Northern Fish Ladder on the Snake River due to high temperatures and low dissolved oxygen levels.

SITE LOCATION Kahlotus, Washington

PIPE NETWORK 115’ long 3” galvanized pipe, ASTM A53 Schedule 40 Air flow of 22 cfm Minimum pressure of 60 psi 7.5 HP Quincy Compressor with 60 gallon receiving tank Klutch Air Compressor Regulator Routing Clamps

HOUSEKEEPING PAD

COMPRESSOR

CHIMNEY 73 FT TALL 3 FT X 3 FT

HOOD 6 FT TALL 18 FT X 18 FT

FISH LADDER EXIT

DAM 110 FT TALL

Fluid Debris*

DESCRIPTION Self-Weight Per ASCE 7-16 Chapter 13 1 ft/s Drag Force 5 ft Pressure Differential Per USACE

TYPE Gravitational Gravitational/Lateral Lateral

ITEM

ESTIMATED COST

Steel Chimney

$1,900,000.00

Compressor

$20,000.00

Pipe System

$30,000.00

Labor and Equipment

$450,000.00

Estimated Total:

$2.4 Million

FISH BEHAVIOR

Fish prefer temperatures around 68°F; our system circulates cooler water from lower depths. Bubbles deter fish; our structure minimizes the interactions between the fish and the bubbles. Our design also creates a current that entices fish to exit the fish ladder

AIR DIFFUSER

STRUCTURAL DESIGN CRITERIA LOAD Dead Seismic

COST ANALYSIS

STEEL DESIGN

Designed per AISC Steel Construction Manual ½” A36 plates walls with 6” ribs and stiffeners to increase rigidity. Protective coatings to resist corrosion Galvanized HSS gravitational and lateral braces 5/16” Fillet welds A325 N-Bolts

Lateral

AIR DIFFUSER

*Special load case that only occurs at the top 8 ft of the structure

Coarse bubble diffuser Circulates 37.5 cfs of water 11.5’ long 1.5” galvanized pipe diffuser 12’ long 3” diameter feeding pipe (20) 0.2” drilled holes per ft of pipe

3,000 psi existing concrete dam LRFD load combinations Seismic risk category 1, soil class B, and site class B System defined as rigid component with limited deformability elements and attachments per ASCE 7-16 Table 13.5.1 Deflection limit of L/180

ANCHORAGE Designed in HILTI Profis Engineering Suite Chimney: KWIK Bolt TZ2 – SS 304 Compressor: KH-EZ Concrete Screw

Faculty Advisor: Dr. Richard Nielsen, P.E. Special Thanks: Dr. Erik Coats, P.E., Dr. Jim Liou, P.E., Dr. Fritz Fiedler, P.E.