Komatsu Rasor Plasma

Page 1

Part#C35-CutChart

RASOR™ 90/120 SilverLine® OXYGEN CUTTING PARAMETERS Rasor 120 Torch K35-006 65-0442-006 O-Ring Kit K35-021 65-0434-021 Cooling Tube, 90/120 Amp (red band) C35-110 65-0442-009

To achieve maximum SilverLine® Electrode life: ▪ A fully used electrode will have a pit depth of .100 in. (2.5 mm). Standard electrodes only achieve a pit depth of .050 in. (1.3 mm). ▪ As the electrode wears, the torch will get closer to the plate. To compensate for this, increase arc voltage in 2-volt increments up to 10 volts higher than the initial setting. ▪ Make sure the torch is purged for at least 30 seconds after each parts change to remove all moisture. ▪ Leak check the torch after purging to make sure all o-ring and metal-to-metal seals are working as designed.

SilverLine® Electrode 90/120 Amp C35-1020 65-0442-001

To achieve maximum nozzle life: ▪ Use 90 amp shield and spacer ring for all cutting. This shield provides greater nozzle protection. ▪ Use at least 3 kg/cm2 (bar) assist gas on 1/4" plate and above. Increased assist gas flow helps to keep the nozzle clean and cool. ▪ Clean the shield and nozzle periodically to remove slag buildup and prevent double arcing. ▪ Use the lowest possible pilot arc setting to achieve arc transfer. Pilot current is adjustable with a toggle switch on the power supply or as a function in the Operator Control Unit (OCU).

Ceramic Guide (with O-Ring) C35-350 65-0434-020 Swirler, 90 Amp (CCW) C35-018 65-0434-018 Swirler, 120 Amp (CW) C35-003 65-0442-003 #8 Nozzle, 0.8 mm C35-160 65-0434-017 #11 Nozzle, 1.1mm C35-180 65-0434-007 #13 Nozzle, 1.3mm C35-002 65-0442-002

Recommended Parameters for Mild Steel Cutting With Oxygen.

Metal thickness

Plasma Pressure

Air Assist

Arc Current

Nozzle Size

Arc Voltage

Pierce Height

Cut Speed

In.

mm

Kg/cm2

Kg/cm2

A

mm

V

In.

in./min

0.062

1.5

6

0

37

0.8

115

.125

200

0.093

2.4

6

0

37

0.8

115

.125

150

0.125

3

6

2-2

45

0.8

120

.125

125

0.187

5

6

2-3

45

0.8

125

.125

80

1/4

6

6

3-4

90

1.1

132

.250

70

5/16

8

6

3-4

90

1.1

136

.250

60

3/8

10

6

4-5

90

1.1

138

.250

50

1/2

12

6

4-5

120

1.3

130

.300

60

5/8

16

6

5-6

120

1.3

130

.300

45

3/4

20

6

5-6

120

1.3

136

.350

35

Cap #1 C35-015

65-0434-015

Spacer Ring, 90 Amp C35-540 65-0434-022 Spacer Ring, 120 Amp C35-250 65-0442-004 Shield Cap, 90 Amp C35-019 65-0434-019 Shield Cap, 120 Amp C35-905 65-0442-005

Cap #2 K35-016

▪ Plasma and Assist pressures are adjusted at Plasma Unit. ▪ Cut speed is adjusted through Select Plate Menu function in the OCU. ▪ Arc voltage, cut height, and pierce height parameters are changed by pressing the 8 on the OCU keypad. ▪ Use feeds and speeds charts in operator’s manual for parameters not listed above.

Rasor® is a registered trademark of Komatsu®, Centricut is in no way affiliated with Komatsu®

1-800-752-7623 ■ 1-603-298-7849 ■ FAX 1-603-298-5938 ■ www.centricut.com Centricut, Two Technology Drive, West Lebanon, NH USA 03784

65-0434-016


Turn static files into dynamic content formats.