Skip to main content

Respiratory Care Equipment Practice Exam - 1245 Verified Questions

Page 1


Respiratory Care Equipment Practice

Exam

Course Introduction

This course provides an in-depth exploration of the equipment essential to respiratory care, including oxygen delivery systems, aerosol and humidity devices, ventilators, airway management tools, and patient monitoring technologies. Emphasis is placed on the principles of operation, safe application, routine maintenance, and troubleshooting of each device. Students will develop practical skills through demonstrations and hands-on experience, ensuring competency in selecting and utilizing appropriate respiratory equipment in various clinical settings to optimize patient outcomes.

Recommended Textbook Mosbys Respiratory Care Equipment 9th Edition by J. M. Cairo

Available Study Resources on Quizplus

15 Chapters

1245 Verified Questions

1245 Flashcards

Source URL: https://quizplus.com/study-set/888

Page 2

Chapter 1: Basic Physics for the Respiratory Therapist

Available Study Resources on Quizplus for this Chatper

107 Verified Questions

107 Flashcards

Source URL: https://quizplus.com/quiz/17542

Sample Questions

Q1) How many degrees Celsius is 373° K?

A) 32° C

B) 100° C

C) 273° C

D) 341° C

Answer: B

Q2) The temperature at which a solid converts to a liquid is the _____ point.

A) freezing

B) melting

C) boiling

D) critical

Answer: B

Q3) If 50% of the gas delivered to a patient is oxygen,its partial pressure at 1 atm is _____ mm Hg.

A) 265.0

B) 356.5

C) 380.0

D) 403.5

Answer: C

To view all questions and flashcards with answers, click on the resource link above.

Page 3

Chapter 2: Principles of Infection Control

Available Study Resources on Quizplus for this Chatper

95 Verified Questions

95 Flashcards

Source URL: https://quizplus.com/quiz/17543

Sample Questions

Q1) Which of the following medical states increase patient susceptibility to nosocomial infection?

A) Hypoglycemia

B) Altered B cells

C) Hyperbilirubinemia

D) Hypogammaglobulinemia

Answer: D

Q2) Human immunodeficiency virus is transmitted by which of the following routes?

A) Direct contact

B) Droplet contact

C) Indirect contact

D) Airborne aerosol

Answer: A

Q3) At high altitudes,sterilization by boiling must be prolonged primarily because of which of the following?

A) Increased oxygen content

B) Reduced oxygen content

C) Increased normal boiling point

D) Reduced normal boiling point

Answer: D

To view all questions and flashcards with answers, click on the resource link above. Page 4

Chapter 3: Manufacture, Storage, and Transport of Medical Gases

Available Study Resources on Quizplus for this Chatper

101 Verified Questions

101 Flashcards

Source URL: https://quizplus.com/quiz/17544

Sample Questions

Q1) What percentage of oxygen does a typical molecular sieve concentrator provide when it is running at 2 L/min?

A) 100%

B) 90%

C) 85%

D) 40%

Answer: B

Q2) The function of the vaporizer of a liquid bulk oxygen system is to:

A) act as a pressure release.

B) reduce the pressure to 50 psig.

C) convert liquid oxygen to gaseous oxygen.

D) allow heat to be released into the environment.

Answer: C

Q3) The gas above liquid oxygen is maintained:

A) between its freezing point and its critical temperature.

B) between its boiling point and its critical temperature.

C) at its critical pressure.

D) at its boiling point.

Answer: B

Page 5

To view all questions and flashcards with answers, click on the resource link above.

Chapter 4: Administering Medical Gases: Regulators,

Flowmeters, and

Available Study Resources on Quizplus for this Chatper

97 Verified Questions

97 Flashcards

Source URL: https://quizplus.com/quiz/17545

Sample Questions

Q1) Contraindications for hyperbaric oxygen therapy consist of all of the following,except:

A) Pneumothorax

B) Obstructive bronchial diseases

C) Upper respiratory infection

D) Skin grafting

Q2) Pressure-compensated flowmeters provide which of the following?

A) Inaccurate estimates of flow

B) Accurate estimates of flow

C) Back pressure

D) A means to estimate leaks

Q3) A patient is receiving supplemental oxygen via a 30% air-entrainment mask set at 8 L/min.The respiratory therapist must increase the supplemental oxygen to 40%.To maintain the same total output,the flow rate must be increased to _____ L/min.

A) 10

B) 14

C) 16

D) 18

To view all questions and flashcards with answers, click on the resource link above.

Page 6

Chapter 5: Airway Management Devices and Advanced

Cardiac Life Support

Available Study Resources on Quizplus for this Chatper

70 Verified Questions

70 Flashcards

Source URL: https://quizplus.com/quiz/17546

Sample Questions

Q1) Oxygen-powered resuscitators are classified as which of the following?

1)Volume-limited

2)Pressure-limited

3)Patient-triggered

4)Operator-triggered

A) 1 and 3

B) 2 and 3

C) 2 and 4

D) 1 and 4

Q2) A blind nasotracheal intubation may be aided by a(n):

A) Combitube.

B) Endotrol tube.

C) foil-wrapped tube.

D) Cole endotracheal tube.

Q3) Laryngeal mask airway placement includes the use of which of the following?

A) Stylet

B) Finger

C) Lighted stylet

D) Miller laryngoscope

To view all questions and flashcards with answers, click on the resource link above. Page 7

Chapter 6: Humidity and Aerosol Therapy

Available Study Resources on Quizplus for this Chatper

88 Verified Questions

88 Flashcards

Source URL: https://quizplus.com/quiz/17547

Sample Questions

Q1) A heat and moisture exchanger is best placed where in the ventilator circuit?

A) Directly at the patient Y-connector

B) Twenty centimeters away from the endotracheal tube

C) At the ventilator outlet

D) At the ventilator inlet

Q2) It is appropriate to suggest which of the following to provide humidification for an intubated patient with a cuffed endotracheal tube,no secretions,and a tidal volume of 500 mL?

A) A heat and moisture exchanger

B) Heated aerosol or humidifier

C) Heated aerosol with humidifier

D) Systemic hydration

Q3) Which of the following statements about breath-actuated nebulizers is not true?

A) They can be used during the entire respiratory cycle.

B) They do not require good hand-breath coordination.

C) They decrease aerosol medication waste.

D) They are not appropriate for some patients with severe airway obstruction.

To view all questions and flashcards with answers, click on the resource link above. Page 8

Chapter 7: Lung Expansion Therapy Devices

Available Study Resources on Quizplus for this Chatper

57 Verified Questions

57 Flashcards

Source URL: https://quizplus.com/quiz/17548

Sample Questions

Q1) What is one major component of a pneumatically powered percussor?

A) Force control

B) Vibration control

C) Amplitude control

D) Convex applicator

Q2) To apply positive airway pressure to a manual resuscitator bag during patient transport,which of the following are most appropriate?

1)Spring-loaded valve

2)Underwater seal

3)Magnetic valve

4)Weighted ball

A) 1 and 2

B) 1 and 3

C) 2 and 4

D) 3 and 4

Q3) Contraindications for incentive spirometry include:

A) post-thoracic surgery.

B) vital capacity less than 10 mL/kg.

C) restrictive pulmonary disease.

D) inspiratory capacity greater than predicted value.

To view all questions and flashcards with answers, click on the resource link above. Page 9

Chapter 8: Assessment of Pulmonary Function

Available Study Resources on Quizplus for this Chatper

120 Verified Questions

120 Flashcards

Source URL: https://quizplus.com/quiz/17549

Sample Questions

Q1) Which type of oxygen analyzer should not be used in the presence of anesthetic gases?

A) Polarographic

B) Paramagnetic

C) Electrical

D) Galvanic

Q2) Airflow is measured by which of the following?

A) "Hot-wire" anemometer

B) Bellows spirometer

C) Water-sealed spirometer

D) Dry rolling seal spirometer

Q3) A 24-year-old skier with a broken femur has been in the postanesthesia care unit for 24 hours and is 12 hours post-extubation with no supplemental oxygen.He is awake,alert,and oriented,and he reports shortness of breath.A capnograph shows decreased PETCO .This patient's current status could be caused by which of the following?

A) Respiratory center depression

B) Pulmonary embolism

C) Muscular paralysis

D) Alveolar shunt

To view all questions and flashcards with answers, click on the resource link above. Page 10

Chapter 9: Assessment of Cardiovascular Function

Available Study Resources on Quizplus for this Chatper

77 Verified Questions

77 Flashcards

Source URL: https://quizplus.com/quiz/17550

Sample Questions

Q1) The QRS vector appears downward in which of the following electrocardiogram leads?

A) II

B) V5

C) aVL

D) aVR

Q2) Pulmonary artery occlusion pressure can be used to estimate:

A) left-atrial preload.

B) left-atrial afterload.

C) left-ventricular end-diastolic pressure.

D) right-ventricular end-diastolic pressure.

Q3) Automatic electrical discharges in the myocardium normally begin within which of the following?

A) Bundle of His

B) Sinoatrial node

C) Bachmann's bundle

D) Atrioventricular node

To view all questions and flashcards with answers, click on the resource link above.

11

Chapter 10: Blood Gas Monitoring

Available Study Resources on Quizplus for this Chatper

96 Verified Questions

96 Flashcards

Source URL: https://quizplus.com/quiz/17551

Sample Questions

Q1) A fluorescent sensor can measure which range of pH values?

A) 6.0 to 7.5

B) 6.5 to 7.5

C) 6.8 to 7.8

D) 7.0 to 8.0

Q2) Which of the following represents the technique used to measure current changes that occur when oxygen is reduced?

A) Blood gas factor

B) Potentiometric

C) Amperometric

D) Tonometry

Q3) Which chemical reaction occurs within the Stow-Severinghaus electrode?

A) CO + H O H CO H + HCO -

B) O + 2H O + 4e- 4OH-

C) 4Ag 4Ag + 4e-

D) EH = 0.0615 * pH

To view all questions and flashcards with answers, click on the resource link above.

Page 12

Chapter 11: Sleep Diagnostics

Available Study Resources on Quizplus for this Chatper

37 Verified Questions

37 Flashcards

Source URL: https://quizplus.com/quiz/17552

Sample Questions

Q1) Sleep spindles occur at a frequency of ____ cycles/s.

A) 4 to 7

B) 9 to 13

C) 14 to 16

D) <3.5

Q2) Slow,rolling,pendulous movement of the eyes is present during which of the following sleep stages?

A) Stage 1 sleep

B) Stage 2 sleep

C) Stages 3 and 4 sleep

D) Rem sleep

Q3) Which characteristics are associated with REM sleep?

1)Lower level tonic activity

2)High-voltage,low-frequency waves on an electroencephalogram

3)Absence of tonic activity on an electromyogram

4)Often absent responsiveness to external stimuli

A) 1 and 2

B) 3 and 4

C) 1,2,and 4

D) 2,3,and 4

To view all questions and flashcards with answers, click on the resource link above. Page 13

Chapter 12: Introduction to Ventilators

Available Study Resources on Quizplus for this Chatper

107 Verified Questions

107 Flashcards

Source URL: https://quizplus.com/quiz/17553

Sample Questions

Q1) A patient receiving continuous positive airway pressure of 7.5 cm H O via a mask and freestanding system appears to be in distress.The patient is using accessory muscles and is diaphoretic. The manometer is fluctuating between -5 cm H O on inspiration and 7.5 cm H O on expiration.The most apparent cause of the patient's distress is which of the following?

A) Leak in the system

B) Improper mask fitting

C) Inadequate flow rate

D) Obstruction of the threshold resistor

Q2) The pressure maintained at the airway during exhalation is known as which of the following?

A) Baseline

B) Proximal

C) Sensitivity

D) Mean airway

Q3) An iron lung is which type of ventilator?

A) Fluidic

B) Positive-pressure

C) Negative-pressure

D) Positive/negative pressure

To view all questions and flashcards with answers, click on the resource link above. Page 14

Chapter 13: Mechanical Ventilators: General-Use Devices

Available Study Resources on Quizplus for this Chatper

45 Verified Questions

45 Flashcards

Source URL: https://quizplus.com/quiz/17554

Sample Questions

Q1) What tidal volume can be delivered by the GE Carestation?

A) 10 to 1200 mL

B) 10 to 1500 mL

C) 20 to 2000 mL

D) 20 to 2500 mL

Q2) Which of the following respiratory mechanics can be measured with the CareFusion AVEA?

1)Esophageal pressure measurement

2)Peak inspiratory pressure/P

3)Inflection point

4)Auto-PEEP

A) 1 only

B) 1 and 3

C) 2,3,and 4

D) 1,2,3,and 4

Q3) What is the range for expiratory trigger sensitivity on the Hamilton G5?

A) 5% to 70% of peak inspiratory flow

B) 10% to 70% of peak inspiratory flow

C) 10% to 80% of peak inspiratory flow

D) 10% to 90% of peak inspiratory flow

To view all questions and flashcards with answers, click on the resource link above. Page 15

Chapter 14: Infant and Pediatric Devices

Available Study Resources on Quizplus for this Chatper

96 Verified Questions

96 Flashcards

Source URL: https://quizplus.com/quiz/17555

Sample Questions

Q1) The oxygen concentration alarm limits on the Dräger Babylog 8000 are set _____ at _____ of the setting.

A) by the operator; ± 5%

B) by the operator; ± 4%

C) automatically; ± 5%

D) automatically; ± 4%

Q2) On the CareFusion V.I.P.Bird Gold Infant Ventilator,the control that ends a pressure support breath in case of a leak also does which of the following to the breath?

A) Flow-cycle

B) Time-cycle

C) Volume-cycle

D) Pressure-cycle

Q3) How many cycles per minute is 15 Hz?

A) 300

B) 600

C) 900

D) 1200

To view all questions and flashcards with answers, click on the resource link above.

16

Chapter 15: Transport, Home Care, and Noninvasive

Ventilatory Devices

Available Study Resources on Quizplus for this Chatper

52 Verified Questions

52 Flashcards

Source URL: https://quizplus.com/quiz/17556

Sample Questions

Q1) Pressure plateau ventilation on the Impact Uni-Vent Eagle 754 is most similar to which of the following modes of ventilation?

A) Airway pressure release ventilation

B) Pressure-regulated volume control

C) Pressure-controlled continuous mandatory ventilation

D) DuoPAP

Q2) Which of the following statements concerning the Newport HT50 ventilator is true?

A) It requires both an oxygen and an air source to operate properly.

B) It can be used to ventilate patients who weigh more than 5 kg.

C) The internal battery can sustain ventilator operation for 10 hours.

D) The "battery empty" message is activated when there are less than 15 minutes left.

Q3) The transport ventilator that can be used on newborns is the:

A) Airon pNeuton

B) Uni-Vent Eagle 754

C) Bio-Med Crossvent 4

D) Pulmonetic Systems LTV 1000

To view all questions and flashcards with answers, click on the resource link above.