Skip to main content

Radiologic Technology Exam Preparation Guide - 345 Verified Questions

Page 1


Radiologic Technology Exam Preparation Guide

Course Introduction

Radiologic Technology is a comprehensive course that introduces students to the principles and practices of diagnostic imaging. The curriculum covers foundational topics such as anatomy, patient care, radiation safety, and image acquisition techniques. Students learn to operate a variety of imaging equipment, interpret radiographic results, and adhere to ethical and legal standards within healthcare environments. Emphasis is placed on developing both technical proficiency and effective communication skills to ensure quality patient experiences and accurate diagnostic outcomes in clinical settings.

Recommended Textbook

Radiographic Imaging and Exposure 3rd Edition by Terri L. Fauber

Available Study Resources on Quizplus

12 Chapters

345 Verified Questions

345 Flashcards

Source URL: https://quizplus.com/study-set/1335

Page 2

Chapter 1: Radiation and Its Discovery

Available Study Resources on Quizplus for this Chatper

20 Verified Questions

20 Flashcards

Source URL: https://quizplus.com/quiz/26639

Sample Questions

Q1) The first radiograph produced by Roentgen, of his wife's hand, required an exposure time of:

A) 15 seconds.

B) 150 seconds.

C) 15 minutes.

D) 150 minutes.

Answer: C

Q2) X-ray photons are capable of traveling around corners.

A)True

B)False

Answer: False

Q3) What type of tube was Roentgen working with in his lab when x-rays were discovered?

A) Crookes tube

B) Fluorescent tube

C) High-vacuum tube

D) Wurzburg tube

Answer: A

To view all questions and flashcards with answers, click on the resource link above. Page 3

Chapter 2: The X-Ray Beam

Available Study Resources on Quizplus for this Chatper

25 Verified Questions

25 Flashcards

Source URL: https://quizplus.com/quiz/26640

Sample Questions

Q1) The positive side of the x-ray tube is the:

A) anode.

B) cathode.

C) window.

D) stream of electrons.

Answer: A

Q2) Effective compensation for the anode heel effect would involve positioning:

A) the thinnest portion of the part under the anode.

B) the thickest portion of the part under the anode.

C) the thinnest portion of the part under the cathode.

D) b and c

Answer: A

Q3) The _____ is the portion of the x-ray tube that contains the filament.

A) cathode

B) anode

C) rotor

D) rotating disk

Answer: A

To view all questions and flashcards with answers, click on the resource link above.

4

Chapter 3: Radiographic Image Formation

Available Study Resources on Quizplus for this Chatper

26 Verified Questions

26 Flashcards

Source URL: https://quizplus.com/quiz/26641

Sample Questions

Q1) The x-ray beam that leaves the patient in the direction of the image receptor is often referred to as:

A) primary radiation.

B) exit radiation.

C) absorbed radiation.

D) scattered radiation.

Answer: B

Q2) Unwanted density on the radiograph due to scatter radiation is called:

A) latent.

B) manifest.

C) fog.

D) backscatter.

Answer: C

Q3) The photoelectric effect is dependent on both the energy of the x-ray photon and the composition of the anatomic tissue.

A)True

B)False

Answer: True

To view all questions and flashcards with answers, click on the resource link above. Page 5

Chapter 4: Radiographic Image Quality: Photographic Properties

Available Study Resources on Quizplus for this Chatper

35 Verified Questions

35 Flashcards

Source URL: https://quizplus.com/quiz/26642

Sample Questions

Q1) If the first radiograph of a foot is done using 4 mAs at 40 inches and a second radiograph is done using 50 inches, how much mAs should be used to maintain density?

A) 1 mAs

B) 2 mAs

C) 6 mAs

D) 12 mAs

Q2) Which one of the following immobilizing devices requires an increase in the exposure technique?

A) Fiberglass cast

B) Plaster cast

C) Air splint

D) b and c

Q3) An abdomen image is done using 66 kVp and 40 mAs. Image density is appropriate but the image has too high (short scale) contrast. Which of these exposure factors would be the best change to make?

A) 56 kVp and 60 mAs

B) 66 kVp and 20 mAs

C) 76 kVp and 40 mAs

D) 76 kVp and 20 mAs

Page 6

To view all questions and flashcards with answers, click on the resource link above.

Chapter 5: Radiographic Image Quality: Geometric Properties

Available Study Resources on Quizplus for this Chatper

25 Verified Questions

25 Flashcards

Source URL: https://quizplus.com/quiz/26643

Sample Questions

Q1) If the object size measures 6.2 inches and the image size measures 7.5 inches, what is the magnification factor?

A) 0.83

B) 1.21

C) 1.30

D) 13.7

Q2) The smallest detail that can be detected in an image refers to:

A) contrast resolution.

B) spatial resolution.

C) geometric unsharpness.

D) distortion.

Q3) The property of the x-ray beam that impacts the unsharpness on the radiograph is beam:

A) quality.

B) quantity.

C) divergence.

D) restriction.

To view all questions and flashcards with answers, click on the resource link above.

Page 7

Chapter 6: Scatter Control

Available Study Resources on Quizplus for this Chatper

30 Verified Questions

30 Flashcards

Source URL: https://quizplus.com/quiz/26644

Sample Questions

Q1) Which beam restriction device can be cut to the size needed?

A) A collimator

B) An aperture diaphragm

C) A cylinder

D) A cone

Q2) Which of the following is NOT a way to reduce the production of scatter radiation?

A) Reduce the exposure field size.

B) Reduce the tissue thickness.

C) Increase the grid ratio.

D) Ask a patient with a large abdomen to lie prone instead of supine.

Q3) In general, when should a grid be used?

A) When part thickness exceeds 4 cm

B) When kV exceeds 40 kVp

C) When kV exceeds 1.02 MeV

D) When part thickness exceeds 10 cm

Q4) The results of the collimator alignment quality control test should demonstrate that the alignment is within 5% of the SID used.

A)True

B)False

To view all questions and flashcards with answers, click on the resource link above. Page 8

Chapter 7: Image Receptors

Available Study Resources on Quizplus for this Chatper

32 Verified Questions

32 Flashcards

Source URL: https://quizplus.com/quiz/26645

Sample Questions

Q1) What is the term used to describe the color of light to which a radiographic film is sensitive?

A) Chromatic spectrometry

B) Orthochromatic sensitivity

C) Panchromatic matching

D) Spectral sensitivity

Q2) What is the term specifically used to describe the emission of light during and after external stimulation?

A) Luminescence

B) Phosphorescence

C) Fluorescence

D) Incandescence

Q3) The DR detector array is typically located:

A) inside the cassette.

B) by the computer keyboard.

C) on top of the table.

D) where you would normally find the Bucky tray.

To view all questions and flashcards with answers, click on the resource link above. Page 9

Chapter 8: Radiographic Film Processing

Available Study Resources on Quizplus for this Chatper

30 Verified Questions

30 Flashcards

Source URL: https://quizplus.com/quiz/26646

Sample Questions

Q1) Stopping the development process takes place during:

A) developing.

B) washing.

C) fixing.

D) drying.

Q2) At what stage does the process of removing unexposed and undeveloped silver halide from the emulsion occur?

A) Developing

B) Fixing

C) Washing

D) Drying

Q3) Which system best achieves agitation, continuous mixing, and filtration of the processing solutions?

A) Transport system

B) Temperature control system

C) Recirculation system

D) Replenishment system

Q4) Radiographs should be dried to remove at least 95% of their moisture.

A)True

B)False

To view all questions and flashcards with answers, click on the resource link above. Page 10

Chapter 9: Sensitometry

Available Study Resources on Quizplus for this Chatper

30 Verified Questions

30 Flashcards

Source URL: https://quizplus.com/quiz/26647

Sample Questions

Q1) What is the range of diagnostic densities on the radiograph?

A) 0.5-1.5

B) 0.25-2.5

C) 0.5-2.0

D) 0.5-3.0

Q2) The _____ indicates the intensity of exposure needed to produce a density of 1.0 plus B+F.

A) speed point

B) dynamic range

C) speed exposure point

D) latitude

Q3) Which portion of the curve should be evaluated to assess the range of exposures over which a film produces diagnostic densities?

A) Toe

B) Straight-line

C) Shoulder

D) a or c

Q4) The lower the speed exposure point, the faster the film speed.

A)True

B)False

Page 11

To view all questions and flashcards with answers, click on the resource link above.

Chapter 10: Exposure Factor Selection

Available Study Resources on Quizplus for this Chatper

22 Verified Questions

22 Flashcards

Source URL: https://quizplus.com/quiz/26648

Sample Questions

Q1) What is the appropriate change in kVp when using a variable kVp/fixed mAs technique chart for a 1 cm change in tissue thickness?

A) 2 kVp

B) 4 kVp

C) 6 kVp

D) 10 kVp

Q2) If a technique chart is being used and the resultant image is overexposed, the technologist should assume the chart is inaccurate and come up with his or her own exposure factors.

A)True

B)False

Q3) What is the purpose of a technique chart?

A) To decrease patient exposure by always using the highest kVp required

B) To ensure consistent image quality

C) To reduce repeats due to technique error and, in turn, reduce patient exposure

D) b and c

Q4) Optimal kVp values for each anatomic area have been established.

A)True

B)False

To view all questions and flashcards with answers, click on the resource link above. Page 12

Chapter 11: Automatic Exposure Control

Available Study Resources on Quizplus for this Chatper

30 Verified Questions

30 Flashcards

Source URL: https://quizplus.com/quiz/26649

Sample Questions

Q1) A good reason to use density control is to make the film darker to compensate for improper centering.

A)True

B)False

Q2) When the radiographer is considering whether to repeat a film using AEC, it is important to determine the reason why the first radiograph failed.

A)True

B)False

Q3) Where is the sensor located in an automatic exposure device with a gas-filled chamber?

A) In front of the patient

B) Behind the Bucky tray

C) In front of the image receptor

D) on the table-top

Q4) Which automatic exposure device works by using a gas-filled chamber?

A) Phototimer

B) Diode sensor

C) Ionization chamber

D) Bucky proliferator

To view all questions and flashcards with answers, click on the resource link above. Page 13

Chapter 12: Digital Imaging

Available Study Resources on Quizplus for this Chatper

40 Verified Questions

40 Flashcards

Source URL: https://quizplus.com/quiz/26650

Sample Questions

Q1) What type of laser is used to release the energy stored in the CR phosphor?

A) Neon-helium

B) Argon

C) Krypton

D) Fluorohalide

Q2) Where is the latent image in computed radiography formed?

A) In the CRT screen

B) In the photostimulable phosphor

C) In the photomultiplier tube

D) In the analog-to-digital converter

Q3) The pixel bit depth determines the amount of shades of gray the system is capable of displaying on the digital image.

A)True

B)False

Q4) Which of the following digital imaging systems uses a photostimulable phosphor?

A) Digital fluoroscopy

B) Computed radiography

C) Direct conversion DR

D) Charge-coupled device

To view all questions and flashcards with answers, click on the resource link above. Page 14

Turn static files into dynamic content formats.

Create a flipbook
Radiologic Technology Exam Preparation Guide - 345 Verified Questions by Quizplus - Issuu