Skip to main content

Radiologic Technology Exam Materials - 345 Verified Questions

Page 1


Radiologic Technology

Exam Materials

Course Introduction

Radiologic Technology is a comprehensive course designed to introduce students to the principles, procedures, and applications of diagnostic imaging. The course covers the fundamental concepts of radiology, including the physics of radiation, safety protocols, image acquisition, and the operation of radiologic equipment. Students learn patient positioning, exposure techniques, image evaluation, and the ethical and legal aspects of radiographic practice. Emphasis is placed on developing proficiency in producing high-quality diagnostic images while minimizing radiation exposure to patients and healthcare staff. This course prepares students for clinical practice and further study in medical imaging sciences.

Recommended Textbook

Radiographic Imaging and Exposure 3rd Edition by Terri L. Fauber

Available Study Resources on Quizplus

12 Chapters

345 Verified Questions

345 Flashcards

Source URL: https://quizplus.com/study-set/1335 Page 2

Chapter 1: Radiation and Its Discovery

Available Study Resources on Quizplus for this Chatper

20 Verified Questions

20 Flashcards

Source URL: https://quizplus.com/quiz/26639

Sample Questions

Q1) The frequency of a wave is the number of waves passing a given point per given unit of time. Frequency is measured in:

A) angstroms.

B) Hertz.

C) inches.

D) eV.

Answer: B

Q2) The distance between two successive crests of a sine wave is known as:

A) an angstrom.

B) frequency.

C) the Greek letter nu.

D) wavelength.

Answer: D

Q3) X-rays carry a negative charge that causes ionization.

A)True

B)False

Answer: False

To view all questions and flashcards with answers, click on the resource link above.

Page 3

Chapter 2: The X-Ray Beam

Available Study Resources on Quizplus for this Chatper

25 Verified Questions

25 Flashcards

Source URL: https://quizplus.com/quiz/26640

Sample Questions

Q1) Which of the following could be defined as the production of an x-ray photon by a collision between the incident electron and a K-shell electron of the tungsten atom?

A) Photoelectric interaction

B) Bremsstrahlung interaction

C) Characteristic interaction

D) Pair production interaction

Answer: C

Q2) The focusing cup:

A) surrounds the anode.

B) has a positive charge.

C) has a negative charge.

D) focuses the x-ray beam.

Answer: C

Q3) What is the base material of the rotating anode?

A) Molybdenum

B) Tungsten

C) Rhenium

D) Beryllium

Answer: A

To view all questions and flashcards with answers, click on the resource link above.

Page 4

Chapter 3: Radiographic Image Formation

Available Study Resources on Quizplus for this Chatper

26 Verified Questions

26 Flashcards

Source URL: https://quizplus.com/quiz/26641

Sample Questions

Q1) When the x-ray photon travels completely through the part, that activity is called:

A) acceleration.

B) penetration.

C) transmission.

D) absorption.

Answer: C

Q2) The x-ray photon that is scattered as a result of the Compton effect CANNOT:

A) be absorbed in the tissue, resulting in additional patient exposure.

B) strike the image receptor, resulting in useful anatomic information.

C) strike the image receptor, resulting in additional density but no useful information.

D) exit the patient, exposing persons near the patient.

Answer: B

Q3) Imaging of the movement of internal structures is known as:

A) image intensification.

B) digital imaging.

C) the photoelectric effect.

D) fluoroscopy.

Answer: D

To view all questions and flashcards with answers, click on the resource link above.

5

Chapter 4: Radiographic Image Quality: Photographic Properties

Available Study Resources on Quizplus for this Chatper

35 Verified Questions

35 Flashcards

Source URL: https://quizplus.com/quiz/26642

Sample Questions

Q1) Contrast is a _____ property of the radiographic image.

A) photographic

B) geometric

C) detail

D) a and c

Q2) Generally speaking, what do additive pathologic conditions require?

A) Increased focal spot size

B) Increased mA

C) Increased kVp

D) Increased SID

Q3) Kilovoltage does not affect radiographic density until adequate penetration is reached.

A)True

B)False

Q4) In order to reduce patient exposure, a _____ kVp and _____ mAs should be used when possible.

A) lower, higher

B) higher, higher

C) higher, lower

D) it makes no difference

To view all questions and flashcards with answers, click on the resource link above. Page 6

Chapter 5: Radiographic Image Quality: Geometric Properties

Available Study Resources on Quizplus for this Chatper

25 Verified Questions

25 Flashcards

Source URL: https://quizplus.com/quiz/26643

Sample Questions

Q1) The unit of line pairs per millimeter is a measure of:

A) distortion.

B) resolution.

C) magnification.

D) quantum mottle.

Q2) Providing clear instructions to the patient is a primary method for reducing unsharpness due to:

A) shape distortion.

B) motion.

C) geometric properties.

D) size distortion.

Q3) The smallest detail that can be detected in an image refers to:

A) contrast resolution.

B) spatial resolution.

C) geometric unsharpness.

D) distortion.

Q4) All of the geometric factors and those that determine the amount of image distortion are equally important for digital and film-screen imaging.

A)True

B)False

To view all questions and flashcards with answers, click on the resource link above. Page 7

Chapter 6: Scatter Control

Available Study Resources on Quizplus for this Chatper

30 Verified Questions

30 Flashcards

Source URL: https://quizplus.com/quiz/26644

Sample Questions

Q1) Which of the following is true of scattered radiation?

A) It is produced when the x-ray beams interact with the air prior to striking the patient and results in significant image fog.

B) It can be prevented by reducing the exposure field, increasing tissue thickness, and using faster screens.

C) It may result in an increase in image contrast that reduces the unsharpness of the image.

D) It is most easily controlled by using collimation and a grid.

Q2) An optimal AP abdomen radiograph can be produced using 40 mAs, 75 kVp and a 12:1 grid. How much mAs would be needed if the only grid available is a 6:1 ratio grid?

A) 20 mAs

B) 24 mAs

C) 67 mAs

D) 80 mAs

Q3) The results of the collimator alignment quality control test should demonstrate that the alignment is within 5% of the SID used.

A)True

B)False

To view all questions and flashcards with answers, click on the resource link above.

Chapter 7: Image Receptors

Available Study Resources on Quizplus for this Chatper

32 Verified Questions

32 Flashcards

Source URL: https://quizplus.com/quiz/26645

Sample Questions

Q1) Which layer of the intensifying screen is closest to the film?

A) Protective layer

B) Base

C) Phosphor layer

D) Emulsion

Q2) Which layer of the intensifying screen is the furthest from the film?

A) Base

B) Reflective layer

C) Phosphor layer

D) Adhesive

Q3) What influences the speed of radiographic film?

A) The amount of silver halide crystals in the emulsion

B) The color of the dye added to the film base

C) The size of the silver halide crystal

D) a and c

Q4) How can you describe a noisy image?

A) An image with noticeable quantum mottle

B) An image that is high-quality and has high contrast

C) An image without quantum mottle

D) An image created with high mAs

To view all questions and flashcards with answers, click on the resource link above. Page 9

Chapter 8: Radiographic Film Processing

Available Study Resources on Quizplus for this Chatper

30 Verified Questions

30 Flashcards

Source URL: https://quizplus.com/quiz/26646

Sample Questions

Q1) Stopping the development process takes place during:

A) developing.

B) washing.

C) fixing.

D) drying.

Q2) Which system best achieves agitation, continuous mixing, and filtration of the processing solutions?

A) Transport system

B) Temperature control system

C) Recirculation system

D) Replenishment system

Q3) While in the developer solution, additional electrons are added to the:

A) fixer.

B) silver.

C) sensitivity specks.

D) water.

Q4) One and one half minutes (90 seconds) is a typical processing cycle.

A)True

B)False

To view all questions and flashcards with answers, click on the resource link above. Page 10

Chapter 9: Sensitometry

Available Study Resources on Quizplus for this Chatper

30 Verified Questions

30 Flashcards

Source URL: https://quizplus.com/quiz/26647

Sample Questions

Q1) When evaluating characteristic curves, which of the following best describes the film with the curve furthest to the left?

A) Fastest

B) Slowest

C) One with the most latitude

D) b and c

Q2) A film that allows 100% of the incident light to be transmitted has a logarithmic value of:

A) 0.

B) 10.

C) 50.

D) 100.

Q3) Which portion of the curve should be evaluated to assess the range of exposures over which a film produces diagnostic densities?

A) Toe

B) Straight-line

C) Shoulder

D) a or c

To view all questions and flashcards with answers, click on the resource link above.

Chapter 10: Exposure Factor Selection

Available Study Resources on Quizplus for this Chatper

22 Verified Questions

22 Flashcards

Source URL: https://quizplus.com/quiz/26648

Sample Questions

Q1) What are calipers used for?

A) To measure the mA

B) To select the S number

C) To select focal spot size

D) To measure the part

Q2) Technique charts are still needed when using Automatic Exposure Control (AEC).

A)True

B)False

Q3) Using the concept of comparative anatomy, if a child's elbow measures the same as an adult wrist and all other procedural variables are the same (i.e., SID, image receptor type, etc.), the child's elbow will require _____ in comparison to the adult wrist.

A) less mAs

B) more mAs

C) the same mAs

D) higher kVp

Q4) Optimal kVp values for each anatomic area have been established.

A)True

B)False

To view all questions and flashcards with answers, click on the resource link above.

Page 12

Chapter 11: Automatic Exposure Control

Available Study Resources on Quizplus for this Chatper

30 Verified Questions

30 Flashcards

Source URL: https://quizplus.com/quiz/26649

Sample Questions

Q1) Why was automatic exposure control (AEC) originally developed?

A) To decrease the need for technique charts

B) To make the technologist more of a "button pusher"

C) To reduce repeats and improve image quality

D) To increase productivity and patient dose

Q2) In order to become familiar with manual technical factors (i.e., setting mAs and kVp and not using AEC), it is very helpful to pay attention to the:

A) exposure time.

B) heat units.

C) density control.

D) mAs readout.

Q3) What does APR stand for?

A) All programming radiology

B) Anatomically programmed radiography

C) Accurately positioned radiographs

D) None of the above

Q4) When exposure factors are selected using APR, the variables should not be adjusted.

A)True

B)False

To view all questions and flashcards with answers, click on the resource link above. Page 13

Chapter 12: Digital Imaging

Available Study Resources on Quizplus for this Chatper

40 Verified Questions

40 Flashcards

Source URL: https://quizplus.com/quiz/26650

Sample Questions

Q1) When the image matrix size is increased, resulting in a decreased pixel size, what happens to spatial resolution?

A) It increases.

B) It decreases.

C) There is no change.

Q2) The basic unit of information in a computer is a(n):

A) bit.

B) byte.

C) word.

D) algorithm.

Q3) Increasing the number of pixels in the image matrix will increase:

A) dynamic range.

B) shades of gray.

C) image brightness.

D) spatial resolution.

Q4) What is the matrix of the digital image composed of?

A) Voxels

B) Pixels

C) Grains

D) Solutes

To view all questions and flashcards with answers, click on the resource link above. Page 14

Turn static files into dynamic content formats.

Create a flipbook
Radiologic Technology Exam Materials - 345 Verified Questions by Quizplus - Issuu