Skip to main content

Radiographic Equipment and Quality Control Midterm Exam - 500 Verified Questions

Page 1


Radiographic Equipment and Quality Control

Midterm Exam

Course Introduction

This course provides an in-depth examination of the operational principles and components of radiographic equipment used in medical imaging. Students will explore the design, function, and maintenance of X-ray machines, image receptors, and ancillary devices. Emphasis is placed on understanding the factors that affect image quality, including exposure parameters, equipment calibration, and image processing techniques. The course also covers quality control procedures essential for ensuring the safety, accuracy, and consistency of diagnostic images, as well as the compliance with regulatory standards. Through theoretical study and practical application, students will develop the skills needed to assess equipment performance, troubleshoot common issues, and implement corrective actions to maintain high-quality radiographic imaging in clinical settings.

Recommended Textbook

Digital Radiography An Introduction for Technologists 1st Edition by Euclid Seeram

Available Study Resources on Quizplus

10 Chapters

500 Verified Questions

500 Flashcards

Source URL: https://quizplus.com/study-set/323 Page 2

Chapter 1: Digital Radiography: An Overview

Available Study Resources on Quizplus for this Chatper

50 Verified Questions

50 Flashcards

Source URL: https://quizplus.com/quiz/5376

Sample Questions

Q1) While DICOM is concerned primarily with images from the digital image acquisition modalities, HL-7 is concerned mainly with textual information from the ____ and ____.

A) HIS; RIS

B) CCD; HIS

C) PACS; RIS

D) CCD; PACS

Answer: A

Q2) Direct conversion digital radiography systems use detectors that convert X-rays directly into ____________________.

Answer: electrical signals

Q3) The application of information technology to medical imaging is referred to as ____________________.

Answer: medical imaging informatics

Q4) An important element of image and data communications is that of ____________________.

Answer: image compression

Q5) Film-based imaging is limited in its ____________________. Answer: contrast resolution

To view all questions and flashcards with answers, click on the resource link above. Page 3

Chapter 2: Digital Imaging Processing Concepts

Available Study Resources on Quizplus for this Chatper

50 Verified Questions

50 Flashcards

Source URL: https://quizplus.com/quiz/5377

Sample Questions

Q1) Pixels in a digital image represent the information contained in a volume of tissue in the patient.What is this volume called?

A) bit depth

B) voxel

C) spatial resolution

D) pixel

Answer: B

Q2) All digital radiography imaging modalities including CR, flat-panel digital radiography, digital mammography, and digital fluoroscopy, utilize digital image processing as a central feature of their operations.

A)True

B)False

Answer: True

Q3) Both past and current day processing technologies include a wide range of image processing algorithms for use in digital radiology.

A)True

B)False

Answer: True

To view all questions and flashcards with answers, click on the resource link above. Page 4

Chapter 3: Computed Radiography: Physics and Technology

Available Study Resources on Quizplus for this Chatper

50 Verified Questions

50 Flashcards

Source URL: https://quizplus.com/quiz/5378

Sample Questions

Q1) ____________________ involves both sampling the analog signal and quantization.

Answer: Digitization

Q2) The emitted light from the CR is optically filtered and collected by the light channeling guide, or light collection optics.

A)True

B)False

Answer: False

Q3) Post-processing deals with shading corrections, pattern recognition, and exposure field recognition.

A)True

B)False

Answer: False

Q4) Quality control (QC)is a component of QA and refers specifically to the ___________________ of important variables that affect image quality and radiation dose.

Answer: monitoring

Q5) Once the fixed stationary IP is exposed, the ____________________ image is acquired using a scanning technology appropriate to the system.

Answer: patent

To view all questions and flashcards with answers, click on the resource link above. Page 5

Chapter 4: Effective Use of Computed Radiography

Available Study Resources on Quizplus for this Chatper

50 Verified Questions

50 Flashcards

Source URL: https://quizplus.com/quiz/5379

Sample Questions

Q1) What would substantial (>2x)overexposure of a body part generate in proportion to the overexposure?

A) high kVp

B) fogging effect

C) low contrast

D) additional scatter

Q2) If the receptor is overexposed by a factor of ____, one would assume that the patient received an equally high exposure.

A) 2X

B) 3X

C) 4X

D) 5X

Q3) With screen/film imaging, the ____________________ of the effect of technical factors is normally based on the image appearance rather that on the physics behind the appearance.

Q4) The optimal alignment is field-centered to the ____________________ with four collimation margins parallel to the cassette edges.

Q5) With cassette-based PSP systems (CR), ____________________ resolution becomes a bit more complicated.

To view all questions and flashcards with answers, click on the resource link above. Page 6

Chapter 5: Flat-Panel Digital Radiography

Available Study Resources on Quizplus for this Chatper

50 Verified Questions

50 Flashcards

Source URL: https://quizplus.com/quiz/5380

Sample Questions

Q1) Flat-panel detectors can be used in portable radiography applications and in applications involving ____________________.

Q2) With selenium drum technology, a negative charge is first placed on the drum, which is then exposed to X-rays.

A)True

B)False

Q3) Which of the following images is obtained initially from the detector and contains artifacts due to the bad detector elements?

A) flat-field

B) pre-processed

C) post-processed

D) raw digital

Q4) A higher MTF value at ____________________ spatial frequencies means that the detector provides better contrast resolution.

Q5) The flat-panel TFT digital detector is designed as a matrix of detector elements, each of which can be regarded as a(n)____________________.

Q6) In imaging, the goal is to obtain good ____________________ information in the image.

To view all questions and flashcards with answers, click on the resource link above. Page 7

Chapter 6: Digital Fluoroscopy

Available Study Resources on Quizplus for this Chatper

50 Verified Questions

50 Flashcards

Source URL: https://quizplus.com/quiz/5381

Sample Questions

Q1) A(n)____ couples the video camera to the television monitor by means of a coaxial cable and control electronics.

A) X-ray tube and generator

B) closed-circuit X-ray television

C) grid-controlled X-ray tube

D) X-ray beam

Q2) The ____________________ ratio of an image intensifier tube is the ratio of the image brightness at the periphery to that at the center of the output screen.

Q3) The ____ changes the image contrast and the ____ changes the brightness of the image.

A) WW; WL

B) WL; WW

C) DSA; WL

D) DSA; WW

Q4) The energy subtraction operation is based on subtraction of images taken at different ___________________.

Q5) ____________________ subtraction involves the digital subtraction of images in time.

To view all questions and flashcards with answers, click on the resource link above. Page 8

Chapter 7: Digital Mammography

Available Study Resources on Quizplus for this Chatper

50 Verified Questions

50 Flashcards

Source URL: https://quizplus.com/quiz/5382

Sample Questions

Q1) ____ uses the principles of conventional tomography to produce tomographic images that are intended to enhance the conspicuity of lesions by blurring out structures above and below the layer of interest.

A) Digital tomosynthesis

B) CAD systems

C) Quantitation

D) Discriminant analysis

Q2) Mammography was developed as a dedicated imaging technique to detect breast cancer that has become prevalent among women in Europe.

A)True

B)False

Q3) Mammography must be able to show the ____________________ between a lesion that is located in the breast and the normal anatomy that is around that lesion.

Q4) Digital mammography (DM)is radiography of the breast using a digital detector coupled to a computer that makes use of digital image processing techniques to enhance the visibility of detail and contrast of the image.

A)True

B)False

To view all questions and flashcards with answers, click on the resource link above.

9

Chapter 8: Picture Archiving and Communication Systems

Available Study Resources on Quizplus for this Chatper

50 Verified Questions

50 Flashcards

Source URL: https://quizplus.com/quiz/5383

Sample Questions

Q1) In order to integrate the two information systems, the RIS and the HIS, several data ____________________ standards have been developed.

Q2) ____ refers to storage devices that must be retrieved by an individual and loaded into a drive for access to images.

A) Online storage

B) Nearline storage

C) Long-term storage

D) Offline storage

Q3) The ultimate goal of workflow is to improve patient care and the efficiency of various processes, from patient registration and image acquisition to report generation, archiving, and image/report distribution throughout the health care enterprise.

A)True

B)False

Q4) For the management and care of patients, PACS have been implemented largely in hospitals and clinics where health care and medical information are the primary focus.These systems can also be used for teaching and ____________________ purposes.

Q5) PACS workstations and their use is that of workstation ____________________.

To view all questions and flashcards with answers, click on the resource link above. Page 10

Chapter 9: Medical Imaging Informatics: An Overview

Available Study Resources on Quizplus for this Chatper

50 Verified Questions

50 Flashcards

Source URL: https://quizplus.com/quiz/5384

Sample Questions

Q1) ____ deals with the structure and function of a computer, and how it can be used to solve problems.

A) Information technology

B) Imaging informatics

C) Computer technology

D) Communications technology

Q2) The results of computer processing can be displayed on monitors for viewing by a human observer.What is this called?

A) storage

B) input

C) processing

D) output

Q3) Individuals who complete both CPIA and CPSA can apply to write which examination?

A) PACS

B) PARCA

C) HIMSS

D) CPSM

Q4) Data transmission requires some sort of ____________________ to do the task.

To view all questions and flashcards with answers, click on the resource link above. Page 11

Chapter 10: Quality Control for Digital Radiography

Available Study Resources on Quizplus for this Chatper

50 Verified Questions

50 Flashcards

Source URL: https://quizplus.com/quiz/5385

Sample Questions

Q1) Acquiring a ____ image according to the specific conditions of the manufacturer makes it possible to verify uniformity, absence of receptor defects, gain, and the value of the DR exposure indicator.

A) flat-field

B) ghost

C) process map

D) digital

Q2) The specific QC tests that are required for digital mammography are those specified by the imaging equipment manufacturer, with the exception of the limitation on maximum radiation dose, which is not more than that allowed for a ____.

A) task allocation matrix

B) GSDF

C) screen-film mammography

D) DR

Q3) The one test that can and should be done for every DR image is a(n)____________________ assessment of image quality before release.

Q4) One of the tasks of the technologist after the DR image is acquired determining whether the image is underexposed or ____________________.

To view all questions and flashcards with answers, click on the resource link above.

12