Skip to main content

Introduction to Radiography Exam Preparation Guide - 621 Verified Questions

Page 1


Introduction to Radiography Exam Preparation Guide

Course Introduction

Introduction to Radiography provides students with a foundational understanding of the principles and practices of medical imaging using X-rays and related technologies. The course covers the history, development, and purpose of radiography in diagnosing and treating diseases. Students will explore basic concepts of radiation physics, image production, radiation safety, and the roles and responsibilities of radiographers within a healthcare team. Emphasis is placed on patient care, ethical considerations, and professional standards, preparing students for further study and practical experience in radiographic procedures.

Recommended Textbook

Radiographic Imaging and Exposure 5th Edition by Terri L. Fauber

Available Study Resources on Quizplus

10 Chapters

621 Verified Questions

621 Flashcards

Source URL: https://quizplus.com/study-set/2258

Page 2

Chapter 1: Radiation and Its Discovery

Available Study Resources on Quizplus for this Chatper

42 Verified Questions

42 Flashcards

Source URL: https://quizplus.com/quiz/44855

Sample Questions

Q1) X-rays are able to interact with certain materials and produce light energy.

A)True

B)False

Answer: True

Q2) X-rays cannot be focused with a lens.

A)True

B)False

Answer: True

Q3) The Greek symbol lambda (l)represents the x-ray's:

A) wavelength.

B) speed.

C) frequency.

D) quantity.

Answer: A

Q4) X-rays used in radiography have wavelengths that are measured in:

A) angstroms.

B) millimeters.

C) centimeters.

D) hertz.

Answer: A

Page 3

To view all questions and flashcards with answers, click on the resource link above.

Chapter 2: The X-Ray Beam

Available Study Resources on Quizplus for this Chatper

66 Verified Questions

66 Flashcards

Source URL: https://quizplus.com/quiz/44856

Sample Questions

Q1) The maximum speed the rotating anode will typically achieve is _____ rpm.

A) 3200

B) 5000

C) 10,000

D) 20,000

Answer: C

Q2) How much is the mAs when 400 mA and 100 ms are used?

A) 4 mAs

B) 40 mAs

C) 400 mAs

D) 4000 mAs

Answer: B

Q3) What is the name of the device in a rotating anode x-ray tube that turns the rotor?

A) Stator

B) Rotor

C) Focusing cup

D) Rheostat

Answer: A

To view all questions and flashcards with answers, click on the resource link above.

4

Chapter 3: Image Formation and Radiographic Quality

Available Study Resources on Quizplus for this Chatper

68 Verified Questions

68 Flashcards

Source URL: https://quizplus.com/quiz/44857

Sample Questions

Q1) Unwanted exposure to the IR due to scatter radiation is called:

A) latent.

B) manifest.

C) fog.

D) cloudiness.

Answer: C

Q2) An area of increased brightness on a display monitor will show decreased density on a film image.

A)True

B)False

Answer: True

Q3) The quality of a radiographic image depends on:

A) brightness-visibility of anatomic structures.

B) accuracy of the recorded anatomic structural lines.

C) contrast-visibility of anatomic structures.

D) A and B.

E) A, B, and C.

Answer: E

To view all questions and flashcards with answers, click on the resource link above. Page 5

Chapter 4: Digital Imaging

Available Study Resources on Quizplus for this Chatper

101 Verified Questions

101 Flashcards

Source URL: https://quizplus.com/quiz/44858

Sample Questions

Q1) Compared with film-screen detectors:

A) digital IRs have a much narrower dynamic range.

B) digital IRs have a much wider dynamic range.

C) digital IRs have no dynamic range.

Q2) Which of the following exposure indicators has an inverse relationship with exposure to the IP?

A) EI (Carestream)

B) lgM (Agfa)

C) S number (Fuji)

D) All have an inverse relationship.

Q3) The DR system does not require a separate reader unit.

A)True

B)False

Q4) An MTF of 1.0 means :

A) no difference in brightness levels.

B) no difference in spatial frequency.

C) maximum difference in brightness levels.

D) A and B.

E) B and C.

To view all questions and flashcards with answers, click on the resource link above. Page 6

Chapter 5: Film-Screen Imaging

Available Study Resources on Quizplus for this Chatper

69 Verified Questions

69 Flashcards

Source URL: https://quizplus.com/quiz/44859

Sample Questions

Q1) Compared to baseline measurements,speed and contrast indicators should not vary more than ±_____ optical density.

A) 0.05

B) 0.10

C) 0.15

D) 0.20

Q2) The greater the film speed,the ______ sensitive it is.

A) more

B) less

Q3) In most 90 s film processors,developer temperature should be kept at approximately:

A) 85° to 88° F.

B) 89° to 91° F.

C) 93° to 95° F.

D) 97° to 99° F.

Q4) Which of the following is a major limitation in film-screen imaging?

A) Limited dynamic range

B) Limited signal-to-noise ratio

C) Increased dynamic range

D) Need for high-resolution monitors

To view all questions and flashcards with answers, click on the resource link above. Page 7

Chapter 6: Exposure Technique Factors

Available Study Resources on Quizplus for this Chatper

67 Verified Questions

67 Flashcards

Source URL: https://quizplus.com/quiz/44860

Sample Questions

Q1) When choosing a grid for an examination,the grid with the highest grid ratio should always be selected in order to most improve image contrast.

A)True

B)False

Q2) If the first radiograph of a foot is done using 4 mAs at 40 in,and a second radiograph is done using 50 in,how much mAs should be used to maintain exposure to the IR?

A) 1 mAs

B) 2 mAs

C) 6 mAs

D) 12 mAs

Q3) The product of milliamperage and exposure time is ______________________ to the quantity of x-rays produced

A) directly proportional

B) inversely proportional

C) not related

Q4) Any increase in magnification results in a decrease in recorded detail.

A)True

B)False

To view all questions and flashcards with answers, click on the resource link above. Page 8

Chapter 7: Scatter Control

Available Study Resources on Quizplus for this Chatper

55 Verified Questions

55 Flashcards

Source URL: https://quizplus.com/quiz/44861

Sample Questions

Q1) Which of the following influences the amount of scatter radiation striking the image receptor but not the production of scatter radiation?

A) Reduce the exposure field size.

B) Reduce the tissue thickness.

C) Increase the grid ratio.

D) Ask a patient with a large abdomen to lie prone instead of supine.

Q2) Grid ratios range from:

A) 2:1 to 6:1.

B) 4:1 to 16:1.

C) 10:1 to 24:1.

D) 20:1 to 32:1.

Q3) The height of the lead strips relative to the distance between the lead strips is the measure of:

A) contrast improvement.

B) grid ratio.

C) Bucky factor.

D) grid selectivity.

Q4) The only reason a grid should be used is to increase radiographic contrast.

A)True

B)False

Page 9

To view all questions and flashcards with answers, click on the resource link above.

Chapter 8: Exposure Technique Selection

Available Study Resources on Quizplus for this Chatper

57 Verified Questions

57 Flashcards

Source URL: https://quizplus.com/quiz/44862

Sample Questions

Q1) Once a predetermined amount of radiation is transmitted through a patient to the AEC detector,which of the following occurs?

A) The x-ray exposure increases.

B) The x-ray exposure decreases.

C) The x-ray exposure terminates.

D) A and B.

Q2) When using a fixed kVp-variable mAs technique chart,if part thickness increases by 5 cm,what needs to happen to the mAs?

A) It should be halved.

B) It should be doubled.

C) It should be quartered.

D) It should be tripled.

Q3) Which of the following is a system that allows the radiographer to select a particular button on the control panel that represents an anatomic area and displays a preprogrammed set of exposure factors?

A) mAs readout

B) Anatomically programmed technique

C) Automatic exposure control

D) Phototiming

To view all questions and flashcards with answers, click on the resource link above.

Chapter 9: Image Evaluation

Available Study Resources on Quizplus for this Chatper

25 Verified Questions

25 Flashcards

Source URL: https://quizplus.com/quiz/44863

Sample Questions

Q1) Using a Konica digital imaging system,if an image's S number is 600 while the optimal range ends at 300,this means that the IR was ______________ and the exposure to the IR needs to be ___________________.

A) underexposed; doubled

B) under exposed; halved

C) overexposed; doubled

D) overexposed; halved

Q2) The amount of luminance (light emission)of a display monitor is the:

A) density.

B) contrast.

C) SID.

D) brightness.

Q3) A digital image with decreased spatial resolution may be due to:

1)Increased central ray angulation

2)Decreased grid ratio

3)Decreased SID

A) 1 and 2 only.

B) 1 and 3 only.

C) 2 and 3 only.

D) 1, 2, and 3.

To view all questions and flashcards with answers, click on the resource link above. Page 11

Chapter 10: Dynamic Imaging: Fluoroscopy

Available Study Resources on Quizplus for this Chatper

71 Verified Questions

71 Flashcards

Source URL: https://quizplus.com/quiz/44864

Sample Questions

Q1) In reference to image intensification,the function that adjusts and maintains the overall image brightness and contrast during the fluoroscopic procedure is:

A) DQE.

B) APR.

C) ABC.

D) AEC.

Q2) A disadvantage of using magnification mode during fluoroscopy is:

A) the image has less resolution.

B) the image brightness is inconsistent.

C) the patient receives additional dose.

D) none of the above.

Q3) When a CCD is exposed to light,it generates and briefly stores light energy.

A)True

B)False

Q4) Which of the following is easier to move around and allows better access to the patient during a procedure?

A) Conventional image intensifier

B) Flat-panel detector in place of image intensifier

C) There is no difference between the two.

To view all questions and flashcards with answers, click on the resource link above. Page 12

Turn static files into dynamic content formats.

Create a flipbook
Introduction to Radiography Exam Preparation Guide - 621 Verified Questions by Quizplus - Issuu