Skip to main content

Diagnostic Imaging Mock Exam - 797 Verified Questions

Page 1


Diagnostic Imaging

Mock Exam

Course Introduction

Diagnostic Imaging is an essential course that explores the principles, techniques, and applications of various imaging modalities used in medical diagnosis. Students will gain a foundational understanding of imaging technologies such as X-ray, ultrasound, computed tomography (CT), magnetic resonance imaging (MRI), and nuclear medicine. The course covers the indications, interpretation of results, and safety considerations associated with each modality. Emphasis is placed on recognizing normal and abnormal anatomical structures, understanding image acquisition processes, and applying diagnostic imaging in clinical settings to enhance patient care and support medical decision-making.

Recommended Textbook

Computed Tomography Physical Principles Clinical Applications and Quality Control 3rd Edition

Available Study Resources on Quizplus

20 Chapters

797 Verified Questions

797 Flashcards

Source URL: https://quizplus.com/study-set/2390 Page 2

Chapter 1: Computed Tomography: An Overview

Available Study Resources on Quizplus for this Chatper

40 Verified Questions

40 Flashcards

Source URL: https://quizplus.com/quiz/47479

Sample Questions

Q1) In computed tomography,

A)a computer is used to reconstruct images of sectional anatomy.

B)a computer is used to calculate radiation dose to the patient.

C)a computer is not required because the physicist calculates the image, which the computer then prints out.

D)special detectors are used to reconstruct sectional images.

Answer: A

Q2) 3D technique

A)Determine tissue types in computed tomography slices

B)Algorithms

C)Image storage

D)Computed tomography dose descriptor

E)Converting electrical signals into digital data

F)Surface-based rendering

Answer: F

Q3) Isodose curves are a dose descriptor used in reporting radiation doses in computed tomography.

A)True

B)False

Answer: True

To view all questions and flashcards with answers, click on the resource link above. Page 3

Chapter 2: Introduction to Computers

Available Study Resources on Quizplus for this Chatper

60 Verified Questions

60 Flashcards

Source URL: https://quizplus.com/quiz/47480

Sample Questions

Q1) The word computer means a machine for solving problems.

A)True

B)False

Answer: True

Q2) Star networks can be applied to which of the following?

A)bus network

B)local area network

C)hierarchical network

D)ring network

Answer: B

Q3) Computer memory capacity is expressed in all of the following, except:

A)megabytes (MB)

B)gigabytes (GB)

C)terabytes (TB)

D)megagram (MG)

Answer: D

Q4) A group of 16 bits equals 1 byte.

A)True

B)False

Answer: False

Page 4

To view all questions and flashcards with answers, click on the resource link above.

Chapter 3: Digital Image Processing

Available Study Resources on Quizplus for this Chatper

48 Verified Questions

48 Flashcards

Source URL: https://quizplus.com/quiz/47481

Sample Questions

Q1) Which image processing hardware is responsible for high-speed processing of the input digital data?

A)digitizer

B)image memory

C)internal image processor

D)host computer

Answer: C

Q2) Which analog-to-digital converter (ADC) is more accurate with respect to sampling an analog signal?

A)2-bit ADC

B)4-bit ADC

C)8-bit ADC

D)16-bit ADC

Answer: D

Q3) A radiograph is an example of an analog image.

A)True

B)False

Answer: True

To view all questions and flashcards with answers, click on the resource link above. Page 5

Chapter 4: Physical Principles of Computed Tomography

Available Study Resources on Quizplus for this Chatper

50 Verified Questions

50 Flashcards

Source URL: https://quizplus.com/quiz/47482

Sample Questions

Q1) All of the following apply to CT except:

A)a computer is used to reconstruct cross-sectional images of the patient

B)mathematical methods are used to reconstruct images

C)x-ray film is used as the detector

D)special detectors are used to detect x rays that have passed through the patient at multiple angles

Q2) The limitations of conventional tomography include all of the following except:

A)superimposition of structures above and below the focal plane

B)image blur from movement of the tube and film

C)contrast degradation from the open beam geometry

D)the presence of ghost images on the film

Q3) Data processing includes all of the following except:

A)raw data preprocessing

B)analog to digital conversion

C)image reconstruction

D)image storage

Q4) Conversion of the attenuation readings into a computed tomography image is accomplished by reconstruction algorithms.

A)True

B)False

To view all questions and flashcards with answers, click on the resource link above. Page 6

Chapter 5: Data Acquisition Concepts

Available Study Resources on Quizplus for this Chatper

50 Verified Questions

50 Flashcards

Source URL: https://quizplus.com/quiz/47483

Sample Questions

Q1) The configuration of the dual-row detector system results in faster volume coverage compared with single-row computed tomography systems.

A)True

B)False

Q2) Seventh-generation scanners use flat-panel digital area detectors.

A)True

B)False

Q3) In which scanner is the apex of the fan beam located outside the detector?

A)third-generation scanner

B)fourth-generation scanner

C)fifth-generation scanner

D)sixth-generation scanner

Q4) Which generation of scanners, also called dual-source computed tomography scanners, consists of two x-ray tubes and two sets of detectors?

A)third generation

B)fourth generation

C)fifth generation

D)sixth generation

To view all questions and flashcards with answers, click on the resource link above. Page 7

Chapter 6: Image Reconstruction

Available Study Resources on Quizplus for this Chatper

35 Verified Questions

35 Flashcards

Source URL: https://quizplus.com/quiz/47484

Sample Questions

Q1) Which of the following removes the classical star pattern (blur) of the back-projection algorithm?

I. filtered back projection

II. interpolation

III. convolution

A)I and II

B)II and III

C)I and III

D)I, II, and III

Q2) Hounsfield's first scanner used _________________ beam projections acquired through a 180-degree rotation.

A)perpendicular

B)parallel

C)long

D)short

Q3) The first operation to which raw data is subjected is referred to as:

A)convolution

B)back projection

C)three-dimensional surface shading

D)interpolation

To view all questions and flashcards with answers, click on the resource link above. Page 8

Chapter 7: Basic Instrumentation

Available Study Resources on Quizplus for this Chatper

39 Verified Questions

39 Flashcards

Source URL: https://quizplus.com/quiz/47485

Sample Questions

Q1) Software modules for computed tomography scanners are intended to: I. facilitate modification of existing packages

II. update existing software

III. revise existing software

A)I and II

B)II and III

C)I and III

D)I, II, and III

Q2) Which of the following allows the technologist to alter picture contrast?

A)touch panel

B)floating keyboard alphanumerical keys

C)floppy disk drive

D)window controls

Q3) The design that incorporates the high-voltage generator on the rotating frame of the computed tomography gantry eliminates:

A)the need for long high-tension cables

B)the need for short high-tension cables

C)the detectors from within the gantry

D)the need for any cables

To view all questions and flashcards with answers, click on the resource link above.

Page 9

Chapter 8: Image Postprocessing and Visualization Tools

Available Study Resources on Quizplus for this Chatper

35 Verified Questions

35 Flashcards

Source URL: https://quizplus.com/quiz/47486

Sample Questions

Q1) One industry standard in data transfer and connectivity is:

A)Digital Imaging and Communications in Medicine

B)hospital information system

C)radiology information system

D)picture archiving and communications system

Q2) The window level in computed tomography is the:

A)center of a range of computed tomography numbers

B)pixel depth

C)range of computed tomography numbers

D)center of the computed tomography matrix

Q3) The window width and window length settings for a given examination of the abdomen are 400 and 0, respectively. Which of the following is true?

A)all structures between -200 and 200 will spread through the gray scale

B)all structures between -200 and 200 will be white

C)all structures between -200 and 200 will be black

D)only those structures above 400 will have different shades of gray

Q4) Windowing is the most common image processing technique in computed tomography.

A)True

B)False

Page 10

To view all questions and flashcards with answers, click on the resource link above.

Chapter 9: Image Quality

Available Study Resources on Quizplus for this Chatper

40 Verified Questions

40 Flashcards

Source URL: https://quizplus.com/quiz/47487

Sample Questions

Q1) Metallic materials usually present as ____________ artifacts on the image.

A)streaks

B)shading

C)ring

D)band

Q2) Which of the following operator-controlled factors affects image noise?

I. kilovoltage

II. slice thickness

III. detector cell size

A)I and II

B)II and III

C)I and III

D)I, II, and III

Q3) As a result of volumetric computed tomography, the scatter-to-primary ratio decreases.

A)True

B)False

Q4) Linearity can be checked by a yearly calibration test.

A)True

B)False

To view all questions and flashcards with answers, click on the resource link above. Page 11

Chapter 10: Radiation Dose in Computed Tomography

Available Study Resources on Quizplus for this Chatper

49 Verified Questions

49 Flashcards

Source URL: https://quizplus.com/quiz/47488

Sample Questions

Q1) Roentgen

A)old unit of effective dose

B)conventional unit of exposure

C)old unit of absorbed dose

D)SI unit of effective dose

E)SI unit of absorbed dose

Q2) What is the term used to describe the instrumentation and methods used to measure patient dose from a computed tomography scanner?

A)computed tomography dosimetry

B)computed tomography absorptiometry

C)radiation intensity

D)dose distribution

Q3) rad

A)old unit of effective dose

B)conventional unit of exposure

C)old unit of absorbed dose

D)SI unit of effective dose

E)SI unit of absorbed dose

To view all questions and flashcards with answers, click on the resource link above.

12

Chapter 11: Single-Slice Spiralhelical Computed

Tomography: Physical Principles and Instrumentation

Available Study Resources on Quizplus for this Chatper

30 Verified Questions

30 Flashcards

Source URL: https://quizplus.com/quiz/47489

Sample Questions

Q1) Table increment and pitch are directly proportional.

A)True

B)False

Q2) The ideal pitch in spiral/helical computed tomography is 2:1.

A)True

B)False

Q3) The overall goal of single-slice spiral/helical volume computed tomography is to increase the volume coverage speed compared with that of the conventional computed tomography scanner.

A)True

B)False

Q4) All of the following affect noise in spiral/helical computed tomography except:

A)beam intensity

B)beam quality

C)detector cell size

D)matrix size

Q5) A number of interpolation algorithms are used to produce the planar data set, but linear interpolation is the simplest approach.

A)True

B)False

To view all questions and flashcards with answers, click on the resource link above. Page 13

Chapter 12: Multislice Spiralhelical Computed Tomography:

Physical Principles and Instrumentation

Available Study Resources on Quizplus for this Chatper

40 Verified Questions

40 Flashcards

Source URL: https://quizplus.com/quiz/47490

Sample Questions

Q1) An algorithm common in multislice computed tomography scanners is the Feldkamp-Davis-Kress algorithm.

A)True

B)False

Q2) Which of the following are considered cone-beam algorithms?

I. approximate algorithms

II. exact algorithms

III. opposed algorithms

A)I and II

B)II and III

C)I and III

D)I, II, and III

Q3) Which of the following describes when raw data for image reconstruction can be selected on the basis of the patient's electrocardiogram?

A)cardiac reconstruction

B)gated reconstruction

C)motion reconstruction

D)timed reconstruction

To view all questions and flashcards with answers, click on the resource link above. Page 14

Chapter 13: Other Technical Applications of Computed

Tomography Imaging: Basic Principles

Available Study Resources on Quizplus for this Chatper

50 Verified Questions

50 Flashcards

Source URL: https://quizplus.com/quiz/47491

Sample Questions

Q1) The computed tomography simulator features all of the following notable components except:

A)flat table top with immobilization devices

B)large gantry aperture

C)smaller detector array

D)registration device

Q2) Image quality parameters in computed tomography fluoroscopy include all of the following except:

A)artifacts

B)contrast resolution

C)density resolution

D)spatial resolution

Q3) Which step in the computed tomography simulation process includes the beam placement and the treatment design that are executed with virtual simulation software?

A)planning of the treatment

B)reconstruction of the images

C)scanning of the patient

D)treatment setup

To view all questions and flashcards with answers, click on the resource link above. Page 15

Chapter 14: Three-Dimensional Computed Tomography: Basic Concepts

Available Study Resources on Quizplus for this Chatper

40 Verified Questions

40 Flashcards

Source URL: https://quizplus.com/quiz/47492

Sample Questions

Q1) Equipment for three-dimensional image processing includes:

I. computed tomography or magnetic resonance imaging scanner console

II. memory and archiving computer

III. stand-alone computer workstations

A)I and II

B)II and III

C)I and III

D)I, II, and III

Q2) Three-dimensional imaging has found applications in all of the following except:

A)cardiovascular surgery

B)neurosurgery

C)ultrasound-guided biopsies

D)visualization of mummies

Q3) Voxel-based processing makes determinations about each voxel and decides to what degree each should contribute to the final three-dimensional image.

A)True

B)False

Q4) Describe the role of the radiological technologist in three-dimensional computed tomography imaging.

16

To view all questions and flashcards with answers, click on the resource link above.

Chapter 15: Virtual Reality Imaging

Available Study Resources on Quizplus for this Chatper

20 Verified Questions

20 Flashcards

Source URL: https://quizplus.com/quiz/47493

Sample Questions

Q1) What technique is used to virtually unroll, slice open, and display a three-dimensional model of the colon?

A)virtual cropping

B)virtual cutting

C)virtual dissection

D)virtual splicing

Q2) Computed tomographic colonoscopy is an integral tool for the examination of colorectal polyp detection.

A)True

B)False

Q3) What is the first step in virtual endoscopy imaging?

A)careful selection of scan parameters

B)image segmentation

C)three-dimensional rendering

D)image display

Q4) Preprocessing involves the use of all of the following except:

A)classification

B)delineation

C)image segmentation

D)noise-filtering algorithms

To view all questions and flashcards with answers, click on the resource link above. Page 17

Chapter 16: Positron Emission Tomographycomputed

Tomography Scanners

Available Study Resources on Quizplus for this Chatper

25 Verified Questions

25 Flashcards

Source URL: https://quizplus.com/quiz/47494

Sample Questions

Q1) The ring diameter of most clinical positron emission tomography scanners is about:

A)1 cm

B)2 cm

C)1 m

D)2 m

Q2) The most commonly used radiopharmaceutical for positron emission tomographic imaging is:

A)(<sup>15</sup>O carbon monoxide)

B)(<sup>13</sup>N ammonia)

C)(<sup>11</sup>C methionine)

D)(<sup>18</sup>F-2-fluoro-2-deoxy-D-glucose (FDG))

Q3) An atom that has too many protons or too many neutrons or they are configured in such a way so as to render the nucleus unstable, is said to be a(n):

A)alpha particle

B)beta particle

C)radioactive atom

D)gamma atom

To view all questions and flashcards with answers, click on the resource link above.

Page 18

Chapter 17: Computed Tomography of the Head, Cerebral Vessels,

Neck, and Spine

Available Study Resources on Quizplus for this Chatper

55 Verified Questions

55 Flashcards

Source URL: https://quizplus.com/quiz/47495

Sample Questions

Q1) Because enhancement persists for hours, at least ___________ hours should elapse after a contrasted examination before an unenhanced scan is obtained.

A)3-5

B)4-6

C)5-7

D)6-8

Q2) Indications for a computed tomographic scan of the neck include all of the following except:

A)carotid stenosis

B)goiter

C)mass

D)polyps

Q3) Coronal images are valuable for scans of the following except:

A)top of the cranial vault

B)roof of the orbit

C)skull base

D)ventricles

To view all questions and flashcards with answers, click on the resource link above.

Page 19

Chapter 18: Computed Tomography of the Body

Available Study Resources on Quizplus for this Chatper

40 Verified Questions

40 Flashcards

Source URL: https://quizplus.com/quiz/47496

Sample Questions

Q1) The purpose of oral contrast agents is to opacify the gastrointestinal tract.

A)True

B)False

Q2) All of the following should be performed by the technologist before the examination except:

A)explain the examination to be performed

B)explain the use of the contrast media

C)have the patient empty the bladder

D)summon the radiologist for the examination

Q3) If the patient has had a recent barium study, sufficient time should be allowed for elimination of the contrast medium.

A)True

B)False

Q4) Proper use of intravenous contrast is not important for detecting masses in the liver.

A)True

B)False

Q5) Computed tomography is the primary method for pelvic assessment. A)True

B)False

To view all questions and flashcards with answers, click on the resource link above. Page 20

Chapter 19: Pediatric Computed Tomography

Available Study Resources on Quizplus for this Chatper

30 Verified Questions

30 Flashcards

Source URL: https://quizplus.com/quiz/47497

Sample Questions

Q1) Radiation exposure control can be achieved by:

I. careful review of all orders

II. coverage limited to the area of interest

III. selection of appropriate scanning parameters

A)I and II

B)II and III

C)I and III

D)I, II, and III

Q2) Computed tomography is not useful in diagnosing congenital abnormalities such as scoliosis, lesions of the vertebral bodies, and osteomyelitis.

A)True

B)False

Q3) Successful computed tomographic angiography in children requires optimization of scan technique and contrast administration.

A)True

B)False

Q4) For chest computed tomography, shallow breathing in the child is adequate.

A)True

B)False

To view all questions and flashcards with answers, click on the resource link above. Page 21

Chapter 20: Quality Control for Computed Tomography

Scanners

Available Study Resources on Quizplus for this Chatper

21 Verified Questions

21 Flashcards

Source URL: https://quizplus.com/quiz/47498

Sample Questions

Q1) Quality control tests that are effective must be objective, quantitative, and easy and can be done very quickly.

A)True

B)False

Q2) Water phantoms are not used for quality control tests.

A)True

B)False

Q3) The tolerance limit for a computed tomography number calibration quality control test is:

A)±3 computed tomography numbers

B)±5 computed tomography numbers

C)±8 computed tomography numbers

D)no tolerance limit has been established

Q4) All quality control tests should be conducted on a monthly basis.

A)True

B)False

Q5) Often a quality control program can result in reduced down time.

A)True

B)False

To view all questions and flashcards with answers, click on the resource link above. Page 22

Turn static files into dynamic content formats.

Create a flipbook