Skip to main content

Diagnostic Imaging Exam Practice Tests - 621 Verified Questions

Page 1


Diagnostic Imaging Exam Practice Tests

Course Introduction

Diagnostic Imaging is a course designed to introduce students to the principles and practices of medical imaging technologies used in the diagnosis and management of diseases. The course covers foundational concepts such as X-ray, computed tomography (CT), magnetic resonance imaging (MRI), ultrasound, and nuclear medicine, highlighting the physical principles behind each modality, image acquisition techniques, and interpretation of imaging results. Students will learn about the indications, advantages, limitations, and safety considerations of each imaging method. Emphasis is placed on correlating imaging findings with clinical scenarios to support diagnostic decision-making in various medical specialties.

Recommended Textbook

Radiographic Imaging and Exposure 5th Edition by Terri L. Fauber

Available Study Resources on Quizplus

10 Chapters

621 Verified Questions

621 Flashcards

Source URL: https://quizplus.com/study-set/2258 Page 2

Chapter 1: Radiation and Its Discovery

Available Study Resources on Quizplus for this Chatper

42 Verified Questions

42 Flashcards

Source URL: https://quizplus.com/quiz/44855

Sample Questions

Q1) The Greek symbol lambda (l)represents the x-ray's:

A) wavelength.

B) speed.

C) frequency.

D) quantity.

Answer: A

Q2) When were x-rays discovered?

A) October 8, 1985

B) November 8, 1895

C) January 23, 1896

D) August 15, 1902

Answer: B

Q3) X-rays were at one time called:

A) Becquerel rays.

B) Roentgen rays.

C) Z-rays.

D) none of the above.

Answer: B

To view all questions and flashcards with answers, click on the resource link above. Page 3

Chapter 2: The X-Ray Beam

Available Study Resources on Quizplus for this Chatper

66 Verified Questions

66 Flashcards

Source URL: https://quizplus.com/quiz/44856

Sample Questions

Q1) The x-ray beam produced with 120 kVp will consist primarily of x-rays produced by bremsstrahlung interactions.

A)True

B)False

Answer: True

Q2) Which of the following types of filtration produce a more uniform exposure to the image receptor?

A) Compensating

B) Half-value

C) Inherent

D) Spatial

Answer: A

Q3) The device that nearly surrounds the filament is the:

A) rotor.

B) focusing cup.

C) stator.

D) anode.

Answer: B

To view all questions and flashcards with answers, click on the resource link above.

4

Chapter 3: Image Formation and Radiographic Quality

Available Study Resources on Quizplus for this Chatper

68 Verified Questions

68 Flashcards

Source URL: https://quizplus.com/quiz/44857

Sample Questions

Q1) Muscle tissue absorbs more radiation than fat tissue because muscle tissue has a:

A) higher atomic number.

B) lower atomic number.

C) higher tissue density.

D) lower tissue density.

Answer: C

Q2) When the entering x-ray photon loses energy and changes its path of travel as a result of interacting with an atom,the interaction is known as the:

A) compensating effect.

B) photoelectric interaction.

C) characteristic effect.

D) Compton effect.

Answer: D

Q3) An increased part thickness results in:

A) increased beam attenuation.

B) decreased beam attenuation.

C) no effect on beam attenuation.

Answer: A

To view all questions and flashcards with answers, click on the resource link above.

5

Chapter 4: Digital Imaging

Available Study Resources on Quizplus for this Chatper

101 Verified Questions

101 Flashcards

Source URL: https://quizplus.com/quiz/44858

Sample Questions

Q1) A method of describing the strength of the radiation exposure compared with the amount of noise apparent in the digital image is the:

A) signal-to-noise ratio.

B) contrast-to-noise ratio.

C) modulation transfer function.

D) detective quantum efficiency.

Q2) Which of the following exposure indicators has an inverse relationship with exposure to the IP?

A) EI (Carestream)

B) lgM (Agfa)

C) S number (Fuji)

D) All have an inverse relationship.

Q3) Soft copy viewing means that the image is being viewed:

A) at a computer.

B) on a soft piece of film.

C) in a soft light environment.

D) none of the above.

Q4) The DQE is higher for DR when compared to CR.

A)True

B)False

To view all questions and flashcards with answers, click on the resource link above. Page 6

Chapter 5: Film-Screen Imaging

Available Study Resources on Quizplus for this Chatper

69 Verified Questions

69 Flashcards

Source URL: https://quizplus.com/quiz/44859

Sample Questions

Q1) While in the developer solution,additional electrons are added to the:

A) fixer.

B) silver.

C) sensitivity specks.

D) water.

Q2) Which film processing system best achieves agitation,continuous mixing,and filtration of the chemical solutions?

A) Transport system

B) Temperature control system

C) Recirculation system

D) Replenishment system

Q3) The developer solution requires a(n)_____ environment for the chemicals to properly function.

A) cold

B) alkaline

C) acidic

D) dry

Q4) The greater the film speed,the ______ sensitive it is.

A) more

B) less

To view all questions and flashcards with answers, click on the resource link above. Page 7

Chapter 6: Exposure Technique Factors

Available Study Resources on Quizplus for this Chatper

67 Verified Questions

67 Flashcards

Source URL: https://quizplus.com/quiz/44860

Sample Questions

Q1) The product of milliamperage and exposure time is ______________________ to the quantity of x-rays produced

A) directly proportional

B) inversely proportional

C) not related

Q2) As compared to a patient with a 24 cm thick abdomen,imaging a patient with a 20 cm thick abdomen will result in _____________ scatter being produced and ______________ image contrast.

A) less; lower

B) more; lower

C) less; higher

D) more; higher

Q3) As compared to a three-phase x-ray unit,a single-phase unit requires higher exposure techniques to produce a comparable image.

A)True

B)False

Q4) Any increase in magnification results in a decrease in recorded detail.

A)True

B)False

To view all questions and flashcards with answers, click on the resource link above. Page 8

Chapter 7: Scatter Control

Available Study Resources on Quizplus for this Chatper

55 Verified Questions

55 Flashcards

Source URL: https://quizplus.com/quiz/44861

Sample Questions

Q1) A device consisting of very thin lead strips with radiolucent interspaces intended to absorb scatter radiation emitted from the patient is a:

A) collimator.

B) aperture diaphragm.

C) cone.

D) grid.

Q2) A grid whose lead strips run perpendicular to the long axis of the grid is called a(n):

A) long dimension grid.

B) short dimension grid.

C) cross-hatch grid.

D) alternating grid.

Q3) An adult's knee measuring 14 cm should be radiographed without a grid.

A)True

B)False

Q4) Grids that move during the exposure:

A) are reciprocating grids.

B) move from top to bottom.

C) are part of the Potter-Bucky diaphragm.

D) A and C.

To view all questions and flashcards with answers, click on the resource link above. Page 9

Chapter 8: Exposure Technique Selection

Available Study Resources on Quizplus for this Chatper

57 Verified Questions

57 Flashcards

Source URL: https://quizplus.com/quiz/44862

Sample Questions

Q1) A good reason to use AEC density control is to increase the exposure to the IR to compensate for improper centering.

A)True

B)False

Q2) A technique chart should be established for:

A) each radiographer.

B) each radiographic tube.

C) each radiologist.

D) A and B.

E) A and C.

Q3) Which of the following is not part of a standardized technique chart?

A) SID

B) OID

C) mA

D) kVp

Q4) Which of the following terms does not belong in the list?

A) Photodiode

B) Ion chamber

C) Ionization chamber

D) mAs readout

To view all questions and flashcards with answers, click on the resource link above. Page 10

Chapter 9: Image Evaluation

Available Study Resources on Quizplus for this Chatper

25 Verified Questions

25 Flashcards

Source URL: https://quizplus.com/quiz/44863

Sample Questions

Q1) A film-screen image with decreased distortion may be due to:

1)Decreased patient thickness

2)Increased SID

3)Increased focal spot size

A) 1 and 2 only.

B) 1 and 3 only.

C) 2 and 3 only.

D) 1, 2, and 3.

Q2) An area of decreased brightness visualized on a computer monitor has ________density on a film image.

A) increased

B) decreased

C) no

Q3) When using a digital imaging system,changing from 40 in SID to 72 in SID would result in _____________ brightness and ____________ contrast.

A) no change in; no change in

B) decreased; increased

C) no change in; decreased

D) decreased; decreased

To view all questions and flashcards with answers, click on the resource link above. Page 11

Chapter 10: Dynamic Imaging: Fluoroscopy

Available Study Resources on Quizplus for this Chatper

71 Verified Questions

71 Flashcards

Source URL: https://quizplus.com/quiz/44864

Sample Questions

Q1) The __________________ is coated with light-emitting crystals to absorb electrons and emit light.

A) input phosphor

B) output phosphor

C) photocathode

D) accelerating anode

Q2) Typical fluoroscopic systems have spatial resolution capabilities in the range of:

A) 2 to 3 Lp/mm.

B) 4 to 6 Lp/mm.

C) 7 to 9 Lp/mm.

D) 10 to 12 Lp/mm.

Q3) This recording system allows the film to be divided into two,four,or more images.

A) Cassette spot imaging

B) Film cameras for spot filming

C) Videotape

D) None of the above

To view all questions and flashcards with answers, click on the resource link above. Page 12

Turn static files into dynamic content formats.

Create a flipbook