Skip to main content

Clinical Quality Improvement in Imaging Final Exam Questions - 165 Verified Questions

Page 1


Clinical Quality Improvement in Imaging

Final Exam Questions

Course Introduction

Clinical Quality Improvement in Imaging explores the principles, methodologies, and practical strategies used to enhance the safety, accuracy, efficiency, and effectiveness of imaging services within healthcare settings. This course covers topics such as clinical audit, performance measurement, process mapping, error reduction, patient-centered care, and the integration of evidence-based practices. Students will learn to identify areas for improvement in imaging workflows, design and implement quality improvement projects, and evaluate outcomes using established metrics. Emphasis is placed on interdisciplinary collaboration, leadership, regulatory requirements, and the use of informatics tools to drive sustained enhancement in imaging quality and patient outcomes.

Recommended Textbook

Quality Management in the Imaging Sciences 5th Edition by Jeffrey Papp

Available Study Resources on Quizplus

15 Chapters

165 Verified Questions

165 Flashcards

Source URL: https://quizplus.com/study-set/1579 Page 2

Chapter 1: Introduction to Quality Management

Available Study Resources on Quizplus for this Chatper

10 Verified Questions

10 Flashcards

Source URL: https://quizplus.com/quiz/31325

Sample Questions

Q1) W.Edwards Deming's management approach can be summarized by his ____ points.

A)5

B)7

C)10

D)14

Answer: D

Q2) Which of the following statements is correct about the 80/20 rule?

A)Twenty percent of the causes result in 80% of the problems.

B)Twenty percent of the problems are the result of 80% of the causes.

C)Both of the above are correct.

D)None of the above is correct.

Answer: A

Q3) The measurement of the level of quality at some point in time with no effort to change or improve the level of care is known as quality

A)management.

B)assurance.

C)assessment.

D)control.

Answer: C

To view all questions and flashcards with answers, click on the resource link above. Page 3

Chapter 2: Quality Management Tools and Procedures

Available Study Resources on Quizplus for this Chatper

10 Verified Questions

10 Flashcards

Source URL: https://quizplus.com/quiz/31326

Sample Questions

Q1) Any activity that costs a facility either money or its reputation is known as

A)risk management.

B)risk assessment.

C)risk analysis.

D)loss potential.

Answer: D

Q2) What is the average amount of background radiation per year in the United States?

A)100 mrem

B)250 mrem

C)360 mrem

D)480 mrem

Answer: C

Q3) Which federal agency is responsible for establishing standards for safety and for monitoring the workplace environment?

A)NRC

B)OSHA

C)FDA

D)NCRP

Answer: B

To view all questions and flashcards with answers, click on the resource link above.

Page 4

Chapter 3: Filmscreen Image Receptors, Darkrooms, and Viewing Conditions

Available Study Resources on Quizplus for this Chatper

15 Verified Questions

15 Flashcards

Source URL: https://quizplus.com/quiz/31327

Sample Questions

Q1) The acceptable variation of luminance uniformity for a single viewbox is A)5%.

B)10%.

C)15%.

D)20%.

Answer: B

Q2) Which of the following can be thought of as the amount of information recorded in an image divided by the information available in the part?

A)Line spread function

B)Point spread function

C)Edge spread function

D)Modulation transfer function

Answer: D

Q3) The amount of light either scattered or emitted by a surface is known as A)luminance.

B)radiant flux.

C)luminous flux.

D)illuminance.

Answer: D

Page 5

To view all questions and flashcards with answers, click on the resource link above.

Chapter 4: Film Processing

Available Study Resources on Quizplus for this Chatper

10 Verified Questions

10 Flashcards

Source URL: https://quizplus.com/quiz/31328

Sample Questions

Q1) The section of an automatic film processor in which the highest temperature is maintained is the

A)developer.

B)fixer.

C)wash.

D)dryer.

Q2) Which of the following is not a function of the circulation system?

A)Maintaining solution concentration

B)Agitation during development

C)Maintaining an even solution temperature

D)Replenishment of solutions

Q3) During developer and fixer replenishment, the flow rates

A)are higher for the fixer.

B)are higher for the developer.

C)are the same for both solutions.

D)vary by processor manufacturer.

To view all questions and flashcards with answers, click on the resource link above. Page 6

Chapter 5: Processor Quality Control

Available Study Resources on Quizplus for this Chatper

10 Verified Questions

10 Flashcards

Source URL: https://quizplus.com/quiz/31329

Sample Questions

Q1) Replenishment rates should not vary by more than ____ of the manufacturer's recommendation.

A)±1%

B)±2%

C)±5%

D)±10%

Q2) Variation during sensitometric testing that occurs because of the test film being run in different parts of the feed tray is called A)bromide drag.

B)locational effect.

C)time of day variability. D)bias.

Q3) Which of the following is obtained by subtracting the Dm n from the Dm ?

A)Speed indicator

B)Mid-density indicator

C)High-density indicator

D)Contrast indicator

To view all questions and flashcards with answers, click on the resource link above. Page 7

Chapter 6: Silver Recovery

Available Study Resources on Quizplus for this Chatper

10 Verified Questions

10 Flashcards

Source URL: https://quizplus.com/quiz/31330

Sample Questions

Q1) To function at maximum efficiency, a silver reclamation device should be attached to the

A)fresh developer replenishment line.

B)used developer drain line.

C)fresh fixer replenishment line.

D)used fixer replenishment line.

Q2) Which of the following will increase the efficiency of a silver recovery system?

A)Decreased dwell time

B)Reduced agitation

C)Reduced surface area

D)Reduced fixer pH

Q3) Which of the following can occur if the current on the electrolytic silver recovery unit is too high?

A)Channeling

B)Sulfurization

C)Rusting

D)Drain stoppage

To view all questions and flashcards with answers, click on the resource link above. Page 8

Chapter 7: Quality Control of X-Ray Generators and

Ancillary Radiographic Equipment

Available Study Resources on Quizplus for this Chatper

20 Verified Questions

20 Flashcards

Source URL: https://quizplus.com/quiz/31331

Sample Questions

Q1) The x-ray tube must be mounted inside its housing so that the central ray exits the housing to within ____ degree(s) of perpendicular.

A)1

B)2

C)3

D)4

Q2) An exposure of 600 mA and 16 ms yields an exposure output of 240 mR.What is the mR/mAs?

A)2.5

B)25

C)250

D)2500

Q3) The kilovolts peak (kVp) must be accurate to A)±2%.

B)±5%.

C)±10%.

D)±15%.

To view all questions and flashcards with answers, click on the resource link above.

Page 9

Chapter 8: Quality Control of Fluoroscopic Equipment

Available Study Resources on Quizplus for this Chatper

10 Verified Questions

10 Flashcards

Source URL: https://quizplus.com/quiz/31332

Sample Questions

Q1) Which type of test tool may be used to demonstrate pincushion distortion?

A)Dosimeter

B)Wire mesh tool

C)Ion chamber

D)Homogenous phantom

Q2) At any combination of tube potential and current, fluoroscopic equipment with an automatic brightness control should not produce an entrance skin exposure exceeding ____ R/min.

A)2.5

B)5

C)10

D)20

Q3) A reduction in brightness at the periphery of the image captured with an image intensifier tube is referred to as

A)pincushion distortion.

B)vignetting.

C)barrel distortion.

D)quantum mottle.

To view all questions and flashcards with answers, click on the resource link above.

Chapter 9: Digital and Advanced Imaging Equipment

Available Study Resources on Quizplus for this Chatper

10 Verified Questions

10 Flashcards

Source URL: https://quizplus.com/quiz/31333

Sample Questions

Q1) Film utilized in dry laser printers uses silver _____ emulsions.

A)bromide

B)iodide

C)behenate

D)sulfide

Q2) CRT monitors for viewing digital images should have a luminance value higher than ____ nit.

A)100

B)170

C)1500

D)3500

Q3) Which of the following uses photostimulable phosphors?

A)Indirect conversion DR system

B)Direct conversion DR system

C)CR systems

D)Flat panel fluoroscopic systems

To view all questions and flashcards with answers, click on the resource link above.

11

Chapter 10: Outcomes Assessment of Radiographic Images

Available Study Resources on Quizplus for this Chatper

10 Verified Questions

10 Flashcards

Source URL: https://quizplus.com/quiz/31334

Sample Questions

Q1) Which of the following will run in the same direction as that of film travel?

A)Pi lines

B)Hesitation lines

C)Guide shoe marks

D)All of the above

Q2) If residual thiosulfate is not properly removed during washing, the radiograph will

A)be underdeveloped.

B)be overdeveloped.

C)turn blue.

D)turn brown.

Q3) Data for determining repeat rates should include at least ____ patients to obtain a statistical sample large enough for valid results.

A)100

B)150

C)250

D)500

To view all questions and flashcards with answers, click on the resource link above.

12

Chapter 11: Mammographic Quality Standards

Available Study Resources on Quizplus for this Chatper

10 Verified Questions

10 Flashcards

Source URL: https://quizplus.com/quiz/31335

Sample Questions

Q1) The contrast indicator, or density difference, value from sensitometric testing of mammographic film processors must not vary by more than ____ from the initial control value.

A)±0.01%

B)±0.03%

C)±0.05%

D)±0.15%

Q2) The B + F value determined from sensitometric testing of mammographic film processors must not vary by more than ____ from the initial control value.

A)±0.01%

B)±0.03%

C)±0.05%

D)±0.10%

Q3) The recommended maximum tolerance of kVp variance for mammographic x-ray generators is

A)1%.

B)2%.

C)5%.

D)10%.

To view all questions and flashcards with answers, click on the resource link above.

Page 13

Chapter 12: Quality Control in Computed Tomography

Available Study Resources on Quizplus for this Chatper

10 Verified Questions

10 Flashcards

Source URL: https://quizplus.com/quiz/31336

Sample Questions

Q1) The CT number of water should not deviate by more than ____ CT numbers from 0.

A)2

B)3

C)5

D)10

Q2) The minimum distance between two objects that allows them to be seen as separate and distinct would define what CT imaging parameter?

A)Low-contrast resolution

B)Uniformity

C)High-contrast resolution

D)Image noise

Q3) Patient dose values for CT scans should remain within ____ of the manufacturer's specifications.

A)±2%

B)±5%

C)±10%

D)±20%

To view all questions and flashcards with answers, click on the resource link above.

14

Chapter 13: Quality Control for Magnetic Resonance

Imaging Equipment

Available Study Resources on Quizplus for this Chatper

10 Verified Questions

10 Flashcards

Source URL: https://quizplus.com/quiz/31337

Sample Questions

Q1) Nonuniformity in the magnetic field can be caused by A)a homogenous main magnetic field.

B)uniformity in the RF coil.

C)the presence of ferromagnetic material within the bore of the magnet.

D)all of the above.

Q2) A change in the strength of the main magnetic field can be caused by A)cryogen boiloff.

B)external ferromagnetic materials.

C)shim coil failure.

D)all of the above.

Q3) The ACR slice position deviation in MR scanners should not exceed ____ mm.

A)1

B)2

C)3

D)5

Q4) The ability of an MR scanner to resolve small objects is known as A)signal-to-noise ratio.

B)high-contrast resolution.

C)spatial resolution.

D)spatial linearity.

To view all questions and flashcards with answers, click on the resource link above. Page 15

Chapter 14: Ultrasound Equipment Quality Assurance

Available Study Resources on Quizplus for this Chatper

10 Verified Questions

10 Flashcards

Source URL: https://quizplus.com/quiz/31338

Sample Questions

Q1) The maximum depth of visualization can indicate changes in A)vertical distance measurement accuracy.

B)axial and lateral resolution.

C)slice thickness.

D)sensitivity.

Q2) A measure of the minimum spacing along the beam axis that still allows two reflectors to be identified is called the A)lateral resolution.

B)axial resolution.

C)axial depth of visualization.

D)axial distance measurement accuracy.

Q3) A scan is done of a uniform section in a phantom, and a vertical shadow emanates from a position on the image corresponding to the transducer surface.This is likely caused by

A)poor TGC control.

B)poor lateral gain.

C)inadequate gray-scale photography.

D)loss of signal from one or more transducer elements.

To view all questions and flashcards with answers, click on the resource link above.

16

Chapter 15: Quality Assurance in Nuclear Medicine

Available Study Resources on Quizplus for this Chatper

10 Verified Questions

10 Flashcards

Source URL: https://quizplus.com/quiz/31339

Sample Questions

Q1) The dose equivalent limit per year for the hands of a nuclear medicine technologist is

A)0.5 rem (5 mSv).

B)5 rem (50 mSv).

C)30 rem (300 mSv).

D)50 rem (500 mSv).

Q2) The ability to produce a linear image with straight lines corresponding to the same straight lines of a bar pattern is known as A)photopeaking.

B)field uniformity.

C)spatial resolution.

D)spatial linearity.

Q3) The discrimination and selection of the gamma photon detected by a scintillation camera are carried out by the A)detection crystal.

B)photomultiplier tube.

C)pulse height analyzer. D)collimator.

To view all questions and flashcards with answers, click on the resource link above. Page 17

Turn static files into dynamic content formats.

Create a flipbook
Clinical Quality Improvement in Imaging Final Exam Questions - 165 Verified Questions by Quizplus - Issuu