Skip to main content

/SG-BWS_safetycontrolunits_datasheet_e%5B1%5D

Page 1

6$)(7<

6(16256

&21752/ 81,76

6* %:6 6(5,(6 7KH 6* %:6 VHULHV SUHVHQWV WZR PRGHOV Â&#x2021; 6* %:6 7 FRQWURO XQLW ZLWK SODVWLF KRXVLQJ IRU ',1 20(*$ UDLO PRXQWLQJ HTXLSSHG ZLWK FODPSV WKDW FDQ FRQQHFW IURP WR SKRWRFHOO FRXSOHV RI WKH 6 67 6/ 67 6 VHULHV ZLWK 266' VDIHW\ RXWSXWV Â&#x2021; 6* %:6 7 07 FRQWURO XQLW ZLWK SODVWLF KRXVLQJ IRU ',1 20(*$ UDLO PRXQWLQJ HTXLSSHG ZLWK FODPSV WKDW FDQ FRQQHFW IURP WR SKRWRFHOO FRXSOHV RI WKH 6 67 6/ 67 6 VHULHV DQG FRQWHPSRUDQHRXVO\ XS WR VDIHW\ OLJKW FXUWDLQV HTXLSSHG ZLWK VDIHW\ RXWSXWV DFWLYDWHG ZLWK WZR 9 UHOD\ 7KH 6* %:6 7 PRGHO LV :,7+287 087,1* )81&7,21 EXW SUHVHQWV ('0 DQG VHOHFWDEOH 0$18$/ $8720$7,& 5(67$57 7KH 6* %:6 7 07 PRGHO LV SURYLGHG ZLWK '28%/( 087,1* )81&7,21 7KH FRQWURO XQLW ¿WV VRPH VDIHW\ RXWSXWV FRQWUROOHG GHSHQGLQJ RQ WKH VWDWXV RI WKH VDIHW\ SKRWRFHOOV FRQQHFWHG WR WKH GHYLFH $ GDQJHU FRQGLWLRQ GHWHFWHG E\ D SKRWRFHOO RU OLJKW FXUWDLQ RSHQV WKH RXWSXWV

+,*+/,*+76 Â&#x2021; 7ZR PRGHOV 6* %:6 7 :,7+287 087,1* )81&7,21 6* %:6 7 07 :,7+ '28%/( 087,1* )81&7,21 Â&#x2021; )DFWRU\ DXWRPDWLRQ VWDQGDUG KRXVLQJ ZLWK FRPSDFW GLPHQVLRQV Â&#x2021; 3RVVLELOLW\ WR FRQQHFW VDIHW\ VLQJOH EHDP DQG VDIHW\ OLJKW FXUWDLQV Â&#x2021; 3/86 IXQFWLRQV 6LQJOH 'RXEOH PXWLQJ (GJHG WULJJHUHG 2YHUULGH 'RXEOH 0XWLQJ /DPS ([WHUQDO 0XWLQJ (QDEOH Â&#x2021; &RQ¿JXUDEOH GHYLFH WKURXJK GLS VZLWFKHV Â&#x2021; 6DWLV¿HV WKH UHTXLUHPHQWV RI NH\ VDIHW\ 6WDQGDUGV VXFK DV &DWHJRU\ RI (1 6,/ RI ,(& DQG SHUIRUPDQFH OHYHOV 3/ H RI (1 ,62

ZZZ DXWRPDWLRQ GDWDORJLF FRP

$33/,&$7,216 ([WUHPH UHOLDELOLW\ DQG VLPSOLFLW\ PDNH WKH 6* %:6 FRQWURO XQLWV WKH LGHDO VROXWLRQ IRU WKH IROORZLQJ DSSOLFDWLRQV Â&#x2021; $XWRPDWLF ZDUHKRXVHV Â&#x2021; 0DFKLQHV IRU IRRG SDFNDJLQJ Â&#x2021; 5RERWV Â&#x2021; $XWRPDWLF DVVHPEOLQJ OLQHV Â&#x2021; 0DFKLQHV IRU 3&% SURGXFWLRQ


SETTINGS • User interface is present on the top of the SG-BWS-T4 for signalling and configuration. • Two units made of 8 dip-switches are present on the top of the SG-BWS-T4-MT model. These switches activate/deactivate and configure additional functions integrated in the device. • Signalling interface and dip-switches are protected from nonauthorized access by transparent lids that can be opened using a specific tool.

DIP

PURPOSE

OFF (Default)

ON

1

ENABLE EDM

ENABLED

DISABLED

2

RESET MODE

AUTOMATIC

MANUAL

3

MUTING TIME-OUT

10 MINUTES

INFINITY

4

MUTING DIRECTION

T

L

2

OVERRIDE

EDGED

TRIGGERED

6

MUTING SELECTION

7

MUTING SELECTION

8

MUTING SELECTION

See specific table

The EDM and MAN/AUTO Restart functions integrated in SG-BWS-T4 model can be selected through specific control unit lines (refer “CONNECTION” section of the present document).

INDICATORS An user interface is present for viewing warnings and setup is present on the top of both SG-BWS-T4 and SG-BWS-T4-MT control units Besides the 7-segment display (for diagnostics purposes), the warning components include 3 LEDs:

LED

INDICATION

POWER

Device is powered correctly

NORMAL

No danger: safety outputs closed

SAFE

Danger or fault: safety outputs open The 7-segment display shows detailed information on control unit current status

www.automation.datalogic.com


DOUBLE MUTING FUNCTION SETTING

Thanks to its two separate muting channels, SG-BWS-T4-MT can accept the muting request output by sensors without interrupting the safety function on light curtain or safety sensors of both channels. PHOTOCELLS

LIGHT CURTAIN 1

000

DIP-SWITCH SETUP

A

A

LIGHT CURTAIN 2 A

001

A

A

B

010

A

B

B

011

-

A

B

100

A

B

-

101

-

A

A

110

A

-

-

111

-

-

-

0=OFF, 1=0N, A(B)=Device associated to channel A(B) Default setting: 000

MUTING WARNING DEVICES To use the Muting function it is also required to connect the external Muting warning (lamp) since control unit would lock out if it is missing. One lamp shall be used per channel. If device is preset for use of just one channel, both warning devices are associated to it: in this way, failure of one of the lamps would not lock out system operation. SG-BWS-T4-MT allows installation of both incandescent lamps and LEDs. For the latter case, polarity shall be carefully complied with, as indicated aside.

Note: the Muting lamp is not supplied with the device. Please refer to â&#x20AC;&#x153;Accessory selection and order information table.â&#x20AC;?


DIMENSIONS SG-BWS-T4

SG-BWS-T4-MT

mm

www.automation.datalogic.com


SG-BWS-T4 CONNECTIONS

NOTE : As SG-BWS-T4 has OSSD Safety outputs in order to have relay outputs, the device must have EDM function connected to the CS-ME EDM relay box as represented below:

SIGNAL

CONTACT

CONNECTION

VCC

1

External 24Vdc

START/TEST/RESET

2

- Contact NC towards 24Vdc

EDM ENABLE

3

- 24Vdc > EDM DEACTIVATED - Not connected > EDM activated

EDM

4

- NC contact of external relays towards 24Vdc (with EDM activated) - Not connected > with EDM deactivated

0V

5

External 0Vdc

6

- OSSD1 (7) > AUTOMATIC RESTART - OSSD2 (8) > MANUAL RESTART Reel of external relay 1 (positive)

MAN/AUTO OSSD1

7

OSSD2

8

Reel of external relay 2 (positive)

RX1

9

PNP output of receiver photocell 1 (black)

RX2

10

PNP output of receiver photocell 2 (black)

RX3

11

PNP output of receiver photocell 3 (black)

RX4

12

PNP output of receiver photocell 4 (black)

TX1

13

TEST of emitter photocell 1 (black)

TX2

14

TEST of emitter photocell 2 (black)

TX3

15

TEST of emitter photocell 3 (black)

TX4

16

TEST of emitter photocell 4 (black)


SG-BWS-T4-MT CONNECTIONS

www.automation.datalogic.com


SIGNAL

CLAMP

CONNECTION

FUNCTION

VDC

1

External 24Vdc

Power supply

START

2

NO contact towards 24Vdc

Reset function

TEST/RESET

3

NC contact towards 24Vdc

Test/Reset function

EDM

4

- NC contact of external relays towards 24Vdc (with EDM activated) - NOT CONNECTED (with EDM deactivated)

Input EDM

0V

5

0Vdc external

Power supply

MUTEN A

6

NO contact towards 24Vdc

Muting activation

MUTEN B

7

NO contact towards 24Vdc

Muting activation

DEFLAMP

8

Positive terminal signaling device

Lamp fault signaling

MUTA1

9

PNP output of the A1 Muting sensor

Muting input

OVRA1

10

Contact of Override A1 NO towards 24Vdc

Override input

MUTB1

11

PNP output of the B1 Muting sensor

Muting input

OVRB1

12

Contact of Override B1 NO towards 24Vdc

Override input

MUTA2

13

PNP output of A2 Muting sensor

Muting input

OVRA2

14

Contact of Override A2 NO towards 24Vdc

Override input

MUTB2

15

PNP output of B2 Muting sensor

Muting input

OVRB2

16

Contact of Override B2 NO towards 24Vdc

Override input

LAMPA-

17

Negative terminal of the A Muting lamp

Muting lamp output

LAMPA+

18

Positive terminal of the A Muting lamp

Muting lamp output

SAFNC11

19

SAFNC21

20

NO relay 230V 1 output

Safety contact Safety contact

LAMPB-

21

Negative terminal of the B Muting lamp

Muting lamp output

LAMPB+

22

Positive terminal of the B Muting lamp

Muting lamp output

SAFNC12

23

SAFNC22

24

RX1

25

PNP output of the photocell receiver 1 (black)

Photocell input

RX2

26

PNP output of the photocell receiver 2 (black)

Photocell input

RX3

27

PNP output of the photocell receiver 3 (black)

Photocell input

RX4

28

PNP output of the photocell receiver 4 (black)

Photocell input

TX1

29

TEST of the photocell emitter 1 (black)

Photocell output

TX2

30

TEST of the photocell emitter 2 (black)

Photocell output

TX3

31

TEST of the photocell emitter l 3 (black)

Photocell output

TX4

32

TEST of the emitter photocell 4 (black)

Photocell output

24VRX12

33

24Vdc photocell receivers 1 and 2 (brown)

Power supply output

NO relay 230V 2 output

Safety contact Safety contact

0VRX12

34

0 Vdc photocell receivers 1 and 2 (blue)

Power supply output

24VRX34

35

24 Vdc photocell receivers 3 and 4 (brown)

Power supply output

0VRX34

36

0Vdc photocell receivers 3 and 4 (blue)

Power supply output

24VTX12

37

24Vdc photocell emitters 1 and 2 (brown)

Power supply output

0VTX12

38

0Vdc photocell emitters 1 and 2 (blue)

Power supply output

24VTX34

39

24Vdc photocell emitters 3 and 4 (brown)

Power supply output

0VTX34

40

0Vdc photocell emitters 3 and 4 (blue)

Power supply output

OSSD11

41

OSSD 1 output of the light curtain 1 (grey)

Light curtain input

OSSD21

42

OSSD 1 output of the light curtain 2 (grey)

Light curtain input

24LRX12

43

24Vdc receivers of light curtain 1 and 2 (brown)

Power supply output

0LRX12

44

0Vdc receivers of light curtain 1 and 2 (brown)

Power supply output

OSSD12

45

OSSD 2 output of light curtain 1 (pink)

Light curtain input

OSSD22

46

OSSD 2 output of light curtain 2 (pink)

Light curtain input

24LTX12

47

24Vdc light curtain emitters 1 and 2 (brown)

Power supply output

0LTX12

48

0Vdc light curtain emitters 1 and 2 (brown)

Power supply output

NO: Normally open – NC: Normally closed

NOTE : Both SG-BWS-T4 and SG-BWS-T4-MT models are equipped with extractable screw clamps. It’s possible to replace them with corresponding spring clamps provided as accessories, if necessary.


TECHNICAL DATA Electrical data SG-BWS-T4

SG-BWS-T4-MT

Power supply:

24 Vdc ± 15%

24 Vdc ± 15%

Consumption:

2.1 W max

3.8 W max

Output contacts:

2 PNP

2 normally open relays, 250 Vac 5A - 24 Vdc 5A

Response time:

Short circuit protection: 1.4 A max

39ms (includes response time of photocells)

Safety category:

Type 4 (ref. EN 61496-1)

Type 4 (ref. EN 61496-1)

SIL:

SIL 3 (ref. IEC 61508 and IEC 62061)

SIL 3 (ref. IEC 61508 and IEC 62061)

PL:

PL e (ref. EN ISO 13849-1)

PL e (ref. EN ISO 13849-1)

PFHd min (1/h):

1,60E-09

1,74E-09

MTTFd (years):

545

428

Reset / EDM selection / auto-man selection

Reset / EDM selection / auto-man selection Single/Double Muting selection Edged/Triggered Override Selection

Accessory functions:

Cat. II (250 Vac) – Cat. III (24Vdc) (ref. EN 50178)

Overload protection: Connections:

Clamps (*)

Clamps (*)

Cable lengths (power supply):

50 m. max

50 m. max

2

2

Pollution degree: Mechanical and environmental data Operating temperature: Storage temperature: Temperature class: Humidity:

0…55°C

0…55°C

-25…+ 70 °C

-25…+ 70 °C

T6

T6

15…95 % (no condensation)

15…95 % (no condensation)

Mechanical protection:

IP 20 (EN 60529)

IP 20 (EN 60529)

0.35 mm amplitude, 10 … 55Hz frequency 20 sweeps for axis, 1octave/min (EN 60068-2-6)

0.35 mm amplitude, 10 … 55Hz frequency 20 sweeps per axis, 1octave/min (EN 60068-2-6)

Shock resistance:

16 ms (10 G) 1.000 shocks for axis (EN 60068-2-29)

16 ms (10 G) 1.000 shocks for axis (EN 60068-2-29)

Housing material:

Nylon PA66

Nylon PA66

Vibrations:

Weight:

(*) Spring clamps are available as accessories

MODEL SELECTION TABLE MODEL

DESCRIPTION

SG-BWS-T4

cat. 4 safety control unit with edm and man/auto restart

ORDER N° 957051000

SG-BWS-T4-MT

cat. 4 safety control unit with double muting

957051010

ACCESSORY SELECTION AND ORDER INFORMATION MODEL

DESCRIPTION

ORDER N°

SG-DM 150

deviating mirror h=150mm

95ASE1670

LMS

muting lamp

95ASE1830

LMS-1

modular muting lamp

95ACC1990

LMS-2

muting lamp – horizontal mounting

95ACC2000

LMS-3

muting lamp - vertical mounting

95ACC2010

SU-LMS-1A

base module for lms-1

95ACC2020

SU-LMS-1B

tower module for lms-1

95ACC2030

UNI EN ISO9001

The company endeavours to continuously improve and renew its products; for this reason the technical data and contents of this catalogue may undergo variations without prior notice. For correct installation and use, the company can guarantee only the data indicated in the instruction manual supplied with the products.

www.automation.datalogic.com

Printed in Italy in January 2010, Rev. 00


Turn static files into dynamic content formats.

Create a flipbook
/SG-BWS_safetycontrolunits_datasheet_e%5B1%5D by OEM International - Issuu