6* %:6 6(5,(6 7KH 6* %:6 VHULHV SUHVHQWV WZR PRGHOV ‡ 6* %:6 7 FRQWURO XQLW ZLWK SODVWLF KRXVLQJ IRU ',1 20(*$ UDLO PRXQWLQJ HTXLSSHG ZLWK FODPSV WKDW FDQ FRQQHFW IURP WR SKRWRFHOO FRXSOHV RI WKH 6 67 6/ 67 6 VHULHV ZLWK 266' VDIHW\ RXWSXWV ‡ 6* %:6 7 07 FRQWURO XQLW ZLWK SODVWLF KRXVLQJ IRU ',1 20(*$ UDLO PRXQWLQJ HTXLSSHG ZLWK FODPSV WKDW FDQ FRQQHFW IURP WR SKRWRFHOO FRXSOHV RI WKH 6 67 6/ 67 6 VHULHV DQG FRQWHPSRUDQHRXVO\ XS WR VDIHW\ OLJKW FXUWDLQV HTXLSSHG ZLWK VDIHW\ RXWSXWV DFWLYDWHG ZLWK WZR 9 UHOD\ 7KH 6* %:6 7 PRGHO LV :,7+287 087,1* )81&7,21 EXW SUHVHQWV ('0 DQG VHOHFWDEOH 0$18$/ $8720$7,& 5(67$57 7KH 6* %:6 7 07 PRGHO LV SURYLGHG ZLWK '28%/( 087,1* )81&7,21 7KH FRQWURO XQLW ¿WV VRPH VDIHW\ RXWSXWV FRQWUROOHG GHSHQGLQJ RQ WKH VWDWXV RI WKH VDIHW\ SKRWRFHOOV FRQQHFWHG WR WKH GHYLFH $ GDQJHU FRQGLWLRQ GHWHFWHG E\ D SKRWRFHOO RU OLJKW FXUWDLQ RSHQV WKH RXWSXWV
+,*+/,*+76 ‡ 7ZR PRGHOV 6* %:6 7 :,7+287 087,1* )81&7,21 6* %:6 7 07 :,7+ '28%/( 087,1* )81&7,21 ‡ )DFWRU\ DXWRPDWLRQ VWDQGDUG KRXVLQJ ZLWK FRPSDFW GLPHQVLRQV ‡ 3RVVLELOLW\ WR FRQQHFW VDIHW\ VLQJOH EHDP DQG VDIHW\ OLJKW FXUWDLQV ‡ 3/86 IXQFWLRQV 6LQJOH 'RXEOH PXWLQJ (GJHG WULJJHUHG 2YHUULGH 'RXEOH 0XWLQJ /DPS ([WHUQDO 0XWLQJ (QDEOH ‡ &RQ¿JXUDEOH GHYLFH WKURXJK GLS VZLWFKHV ‡ 6DWLV¿HV WKH UHTXLUHPHQWV RI NH\ VDIHW\ 6WDQGDUGV VXFK DV &DWHJRU\ RI (1 6,/ RI ,(& DQG SHUIRUPDQFH OHYHOV 3/ H RI (1 ,62
ZZZ DXWRPDWLRQ GDWDORJLF FRP
$33/,&$7,216 ([WUHPH UHOLDELOLW\ DQG VLPSOLFLW\ PDNH WKH 6* %:6 FRQWURO XQLWV WKH LGHDO VROXWLRQ IRU WKH IROORZLQJ DSSOLFDWLRQV ‡ $XWRPDWLF ZDUHKRXVHV ‡ 0DFKLQHV IRU IRRG SDFNDJLQJ ‡ 5RERWV ‡ $XWRPDWLF DVVHPEOLQJ OLQHV ‡ 0DFKLQHV IRU 3&% SURGXFWLRQ
SETTINGS • User interface is present on the top of the SG-BWS-T4 for signalling and configuration. • Two units made of 8 dip-switches are present on the top of the SG-BWS-T4-MT model. These switches activate/deactivate and configure additional functions integrated in the device. • Signalling interface and dip-switches are protected from nonauthorized access by transparent lids that can be opened using a specific tool.
DIP
PURPOSE
OFF (Default)
ON
1
ENABLE EDM
ENABLED
DISABLED
2
RESET MODE
AUTOMATIC
MANUAL
3
MUTING TIME-OUT
10 MINUTES
INFINITY
4
MUTING DIRECTION
T
L
2
OVERRIDE
EDGED
TRIGGERED
6
MUTING SELECTION
7
MUTING SELECTION
8
MUTING SELECTION
See specific table
The EDM and MAN/AUTO Restart functions integrated in SG-BWS-T4 model can be selected through specific control unit lines (refer “CONNECTION” section of the present document).
INDICATORS An user interface is present for viewing warnings and setup is present on the top of both SG-BWS-T4 and SG-BWS-T4-MT control units Besides the 7-segment display (for diagnostics purposes), the warning components include 3 LEDs:
LED
INDICATION
POWER
Device is powered correctly
NORMAL
No danger: safety outputs closed
SAFE
Danger or fault: safety outputs open The 7-segment display shows detailed information on control unit current status
www.automation.datalogic.com
DOUBLE MUTING FUNCTION SETTING
Thanks to its two separate muting channels, SG-BWS-T4-MT can accept the muting request output by sensors without interrupting the safety function on light curtain or safety sensors of both channels. PHOTOCELLS
LIGHT CURTAIN 1
000
DIP-SWITCH SETUP
A
A
LIGHT CURTAIN 2 A
001
A
A
B
010
A
B
B
011
-
A
B
100
A
B
-
101
-
A
A
110
A
-
-
111
-
-
-
0=OFF, 1=0N, A(B)=Device associated to channel A(B) Default setting: 000
MUTING WARNING DEVICES To use the Muting function it is also required to connect the external Muting warning (lamp) since control unit would lock out if it is missing. One lamp shall be used per channel. If device is preset for use of just one channel, both warning devices are associated to it: in this way, failure of one of the lamps would not lock out system operation. SG-BWS-T4-MT allows installation of both incandescent lamps and LEDs. For the latter case, polarity shall be carefully complied with, as indicated aside.
Note: the Muting lamp is not supplied with the device. Please refer to “Accessory selection and order information table.�
DIMENSIONS SG-BWS-T4
SG-BWS-T4-MT
mm
www.automation.datalogic.com
SG-BWS-T4 CONNECTIONS
NOTE : As SG-BWS-T4 has OSSD Safety outputs in order to have relay outputs, the device must have EDM function connected to the CS-ME EDM relay box as represented below:
SIGNAL
CONTACT
CONNECTION
VCC
1
External 24Vdc
START/TEST/RESET
2
- Contact NC towards 24Vdc
EDM ENABLE
3
- 24Vdc > EDM DEACTIVATED - Not connected > EDM activated
EDM
4
- NC contact of external relays towards 24Vdc (with EDM activated) - Not connected > with EDM deactivated
0V
5
External 0Vdc
6
- OSSD1 (7) > AUTOMATIC RESTART - OSSD2 (8) > MANUAL RESTART Reel of external relay 1 (positive)
MAN/AUTO OSSD1
7
OSSD2
8
Reel of external relay 2 (positive)
RX1
9
PNP output of receiver photocell 1 (black)
RX2
10
PNP output of receiver photocell 2 (black)
RX3
11
PNP output of receiver photocell 3 (black)
RX4
12
PNP output of receiver photocell 4 (black)
TX1
13
TEST of emitter photocell 1 (black)
TX2
14
TEST of emitter photocell 2 (black)
TX3
15
TEST of emitter photocell 3 (black)
TX4
16
TEST of emitter photocell 4 (black)
SG-BWS-T4-MT CONNECTIONS
www.automation.datalogic.com
SIGNAL
CLAMP
CONNECTION
FUNCTION
VDC
1
External 24Vdc
Power supply
START
2
NO contact towards 24Vdc
Reset function
TEST/RESET
3
NC contact towards 24Vdc
Test/Reset function
EDM
4
- NC contact of external relays towards 24Vdc (with EDM activated) - NOT CONNECTED (with EDM deactivated)
Input EDM
0V
5
0Vdc external
Power supply
MUTEN A
6
NO contact towards 24Vdc
Muting activation
MUTEN B
7
NO contact towards 24Vdc
Muting activation
DEFLAMP
8
Positive terminal signaling device
Lamp fault signaling
MUTA1
9
PNP output of the A1 Muting sensor
Muting input
OVRA1
10
Contact of Override A1 NO towards 24Vdc
Override input
MUTB1
11
PNP output of the B1 Muting sensor
Muting input
OVRB1
12
Contact of Override B1 NO towards 24Vdc
Override input
MUTA2
13
PNP output of A2 Muting sensor
Muting input
OVRA2
14
Contact of Override A2 NO towards 24Vdc
Override input
MUTB2
15
PNP output of B2 Muting sensor
Muting input
OVRB2
16
Contact of Override B2 NO towards 24Vdc
Override input
LAMPA-
17
Negative terminal of the A Muting lamp
Muting lamp output
LAMPA+
18
Positive terminal of the A Muting lamp
Muting lamp output
SAFNC11
19
SAFNC21
20
NO relay 230V 1 output
Safety contact Safety contact
LAMPB-
21
Negative terminal of the B Muting lamp
Muting lamp output
LAMPB+
22
Positive terminal of the B Muting lamp
Muting lamp output
SAFNC12
23
SAFNC22
24
RX1
25
PNP output of the photocell receiver 1 (black)
Photocell input
RX2
26
PNP output of the photocell receiver 2 (black)
Photocell input
RX3
27
PNP output of the photocell receiver 3 (black)
Photocell input
RX4
28
PNP output of the photocell receiver 4 (black)
Photocell input
TX1
29
TEST of the photocell emitter 1 (black)
Photocell output
TX2
30
TEST of the photocell emitter 2 (black)
Photocell output
TX3
31
TEST of the photocell emitter l 3 (black)
Photocell output
TX4
32
TEST of the emitter photocell 4 (black)
Photocell output
24VRX12
33
24Vdc photocell receivers 1 and 2 (brown)
Power supply output
NO relay 230V 2 output
Safety contact Safety contact
0VRX12
34
0 Vdc photocell receivers 1 and 2 (blue)
Power supply output
24VRX34
35
24 Vdc photocell receivers 3 and 4 (brown)
Power supply output
0VRX34
36
0Vdc photocell receivers 3 and 4 (blue)
Power supply output
24VTX12
37
24Vdc photocell emitters 1 and 2 (brown)
Power supply output
0VTX12
38
0Vdc photocell emitters 1 and 2 (blue)
Power supply output
24VTX34
39
24Vdc photocell emitters 3 and 4 (brown)
Power supply output
0VTX34
40
0Vdc photocell emitters 3 and 4 (blue)
Power supply output
OSSD11
41
OSSD 1 output of the light curtain 1 (grey)
Light curtain input
OSSD21
42
OSSD 1 output of the light curtain 2 (grey)
Light curtain input
24LRX12
43
24Vdc receivers of light curtain 1 and 2 (brown)
Power supply output
0LRX12
44
0Vdc receivers of light curtain 1 and 2 (brown)
Power supply output
OSSD12
45
OSSD 2 output of light curtain 1 (pink)
Light curtain input
OSSD22
46
OSSD 2 output of light curtain 2 (pink)
Light curtain input
24LTX12
47
24Vdc light curtain emitters 1 and 2 (brown)
Power supply output
0LTX12
48
0Vdc light curtain emitters 1 and 2 (brown)
Power supply output
NO: Normally open – NC: Normally closed
NOTE : Both SG-BWS-T4 and SG-BWS-T4-MT models are equipped with extractable screw clamps. It’s possible to replace them with corresponding spring clamps provided as accessories, if necessary.
TECHNICAL DATA Electrical data SG-BWS-T4
SG-BWS-T4-MT
Power supply:
24 Vdc ± 15%
24 Vdc ± 15%
Consumption:
2.1 W max
3.8 W max
Output contacts:
2 PNP
2 normally open relays, 250 Vac 5A - 24 Vdc 5A
Response time:
Short circuit protection: 1.4 A max
39ms (includes response time of photocells)
Safety category:
Type 4 (ref. EN 61496-1)
Type 4 (ref. EN 61496-1)
SIL:
SIL 3 (ref. IEC 61508 and IEC 62061)
SIL 3 (ref. IEC 61508 and IEC 62061)
PL:
PL e (ref. EN ISO 13849-1)
PL e (ref. EN ISO 13849-1)
PFHd min (1/h):
1,60E-09
1,74E-09
MTTFd (years):
545
428
Reset / EDM selection / auto-man selection
Reset / EDM selection / auto-man selection Single/Double Muting selection Edged/Triggered Override Selection
Accessory functions:
Cat. II (250 Vac) – Cat. III (24Vdc) (ref. EN 50178)
Overload protection: Connections:
Clamps (*)
Clamps (*)
Cable lengths (power supply):
50 m. max
50 m. max
2
2
Pollution degree: Mechanical and environmental data Operating temperature: Storage temperature: Temperature class: Humidity:
0…55°C
0…55°C
-25…+ 70 °C
-25…+ 70 °C
T6
T6
15…95 % (no condensation)
15…95 % (no condensation)
Mechanical protection:
IP 20 (EN 60529)
IP 20 (EN 60529)
0.35 mm amplitude, 10 … 55Hz frequency 20 sweeps for axis, 1octave/min (EN 60068-2-6)
0.35 mm amplitude, 10 … 55Hz frequency 20 sweeps per axis, 1octave/min (EN 60068-2-6)
Shock resistance:
16 ms (10 G) 1.000 shocks for axis (EN 60068-2-29)
16 ms (10 G) 1.000 shocks for axis (EN 60068-2-29)
Housing material:
Nylon PA66
Nylon PA66
Vibrations:
Weight:
(*) Spring clamps are available as accessories
MODEL SELECTION TABLE MODEL
DESCRIPTION
SG-BWS-T4
cat. 4 safety control unit with edm and man/auto restart
ORDER N° 957051000
SG-BWS-T4-MT
cat. 4 safety control unit with double muting
957051010
ACCESSORY SELECTION AND ORDER INFORMATION MODEL
DESCRIPTION
ORDER N°
SG-DM 150
deviating mirror h=150mm
95ASE1670
LMS
muting lamp
95ASE1830
LMS-1
modular muting lamp
95ACC1990
LMS-2
muting lamp – horizontal mounting
95ACC2000
LMS-3
muting lamp - vertical mounting
95ACC2010
SU-LMS-1A
base module for lms-1
95ACC2020
SU-LMS-1B
tower module for lms-1
95ACC2030
UNI EN ISO9001
The company endeavours to continuously improve and renew its products; for this reason the technical data and contents of this catalogue may undergo variations without prior notice. For correct installation and use, the company can guarantee only the data indicated in the instruction manual supplied with the products.