STAIR TREAD AND STAIRWAY

![]()

The Building Code of Australia (BCA) and Australian Standards (AS1428.4) now require all new buildings to include slip-resistant stair treads. This is to provide safe access and mobility to all users.
According to the Building Code of Australia and Disability Discrimination Act (ODA), it is also mandatory to provide a stair nosing with horizontal depth between 50mm and 75mm on all steps.
TABLE 3A
MINIMUM WET PENDULUM TEST OR OIL-WET INCLINING PLATFORM CLASSIFICATIONS THAT ARE DEEMED-TO-SATISFY THE BUILDING APPLICATIONS IN THE NCC
Location
Stair Treads and Stairway Landings in Buildings Covered by NCC Volumes One and Two
Stair treads and a stairway landing (when dry)
Stair treads and a stairway landing (when wet)
Nosings for Stair Treads and Stairway Landings in Buildings Covered by NCC Volumes One and Two
Dry stair tread, a stair non-skid nosing strip and a stairway landing
Wet stair tread, a stair non-skid nosing strip and a stairway landing
Ramps in Buildings Covered by NCC Volumes One and Two
Ramps not steeper than 1:14 gradient (when dry)
Ramps not steeper than 1:14 gradient (when wet)
Ramps steeper than 1:14 up but not steeper than 1:8 (when dry)
Ramps steeper than 1:14 up but not steeper than 1:8 (when wet)
***NOTE: a landing is considered to be an area between two or more flights of one staircase.
If tiled stairs don’t comply with the above standards stated in TABLE 3A., stair treads or a stair nosing needs to be applied.
Such profiles include:
• aluminium stair nosing
• rubber stair nosing
• fibreglass stair nosing
• metal anti-slip strips
• fibreglass anti-slip strips


NATTT2000
Aluminum Stair Nosing
RST50CLEAR
3.62m length
50mm thick
10mm lip
RO $214.65/ea ($59.30/LM)
NATTT2001
Aluminum Stair Nosing
RST50CLEAR
3.62m length
50mm thick
10mm lip
RO $276.60/ea ($76.40/LM)