HOSE BIBB (CENTERLINE)
36"
FLOOR DRAIN (FD), SIZE & TYPE
ICE MAKER OUTLET BOX (CENTER OF BOX)
24"
ROOF DRAIN (RD), SIZE & TYPE
STORE MUST BE KEPT IN OPERATION. ARRANGE ALL WORK TO KEEP DISRUPTIONS TO STORE OPERATIONS TO A MINIMUM. COORDINATE WITH EXISTING AND NEW CONSTRUCTION. PAY ALL NECESSARY FEES AND PERMITS.
JANITOR'S SINK FAUCET FITTINGS (CENTERLINE)
42"
BALL VALVE
3.
4.
5.
6.
7.
8.
9.
IF NEW CONSTRUCTION DISRUPTS EXISTING UNDERGROUND SERVICES (GAS, SEWER, DOMESTIC WATER, FIRE SPRINKLER, ETC.), PROVIDE ALL MATERIALS AND LABOR AS REQUIRED TO MAINTAIN THEIR PROPER OPERATION. CONTRACTOR IS RESPONSIBLE FOR UTILIZING OWNER APPROVED ROOFING CONTRACTORS FOR CUTTING AND PATCHING ROOF. EXISTING PIPE SIZES AND LOCATIONS HAVE NOT BEEN FIELD VERIFIED. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY LOCATION AND SIZES OF ALL EXISTING PIPING THAT IS BEING CONNECTED TO OR MODIFIED, AND TO VERIFY THAT PROPER SLOPES AND ELEVATIONS ARE AVAILABLE. MAINTAIN MINIMUM SLOPE OF 1/8" PER FOOT FOR SAN SEWER PIPING 3" OR LARGER. MAINTAIN MINIMUM SLOPE OF 1/4" PER FOOT FOR SAN SEWER PIPING SMALLER THAN 3". REF ARCH. FOR TRENCHING REQUIREMENTS. PLUMBING CONTRACTOR SHALL VERIFY EXISTING SEWER AND VENT PIPE SIZE AND ELEVATION AND SHALL VERIFY THAT PROPER SLOPES ARE AVAILABLE BEFORE CUTTING FLOOR SLAB FOR NEW SEWER PIPING.
LAVATORY OR SINK STANDARD HEIGHT (RIM) ADA ACCESSIBLE (RIM) CHILD HEIGHT (RIM)
CONTROL VALVE 31" 34" 24"
CHECK VALVE
NON FREEZE WALL HYDRANT (AFG TO CENTERLINE)
18"
BALANCING VALVE WITH PRESSURE PORTS
SHOWER HEAD MEN (CENTERLINE) WOMEN (CENTERLINE) SHOWER VALVE STANDARD HEIGHT - MEN (CENTERLINE) STANDARD HEIGHT - WOMEN (CENTERLINE) ADA ACCESSIBLE (CENTERLINE)
SHUTOFF VALVE
78" 72"
WATER METER STRAINER
48" 42" 38" TO 48"
STRAINER WITH BLOWOFF RELIEF/SAFETY VALVE
URINAL
SOLENOID VALVE
STANDARD HEIGHT (RIM) ADA ACCESSIBLE (RIM) CHILD HEIGHT (RIM)
24" 17" 14"
GAS PRESSURE REGULATOR
WASHING MACHINE OUTLET BOX (RIM) WATER CLOSET STANDARD HEIGHT (RIM) ADA ACCESSIBLE (TOP OF SEAT) CHILD HEIGHT (RIM)
PRESSURE REDUCING VALVE
42"
THERMOSTATIC MIXING VALVE
PA
15" 17" TO 19" 10"
WATER COOLER OR DRINKING FOUNTAIN STANDARD HEIGHT (SPOUT) ADA ACCESSIBLE (SPOUT) CHILD HEIGHT (SPOUT)
EJ
PIPE ANCHOR EXPANSION JOINT BACKFLOW PREVENTER
41" 36" 30"
PRESSURE GAUGE
PROVIDE ACCESS DOORS TO NEW WATER VALVES AND CLEANOUTS AS NECESSARY WHEN INSTALLED IN INACCESSIBLE AREAS.
THERMOMETER
PLUMBING CONTRACTOR SHALL PROVIDE ONE YEAR WARRANTY FOR PROPER SEWER SYSTEM OPERATION.
FLANGE CONNECTION
10. SANITARY DRAINAGE LINES AND FITTINGS (DRAIN, WASTE AND VENT) SHALL BE CAST IRON, COATED INSIDE AND OUTSIDE. WHERE PERMITTED BY LOCAL CODES, PVC-DWV PLASTIC SCHEDULE 40 MAY BE USED IN LIEU OF CAST IRON. 11. WATER PIPING ABOVE GRADE SHALL BE TYPE "L" HARD DRAWN COPPER JOINED WITH WROUGHT COPPER FITTINGS. MAKE JOINTS USING LEAD-FREE SOLDER AND A NON-CORROSIVE, PASTE-TYPE FLUX. MAKE PIPING CONNECTIONS TO A FIXTURE WITH CHROME-PLATED SEAMLESS BRASS TUBE. INSULATE HOT & COLD WATER PIPING WITH RIGID GLASS FIBER A MINIMUM OF 1/2" THICK WITH WHITE ALL-SERVICE JACKET (VAPOR RETARDER). 12. PROVIDE AUTOMATIC TRAP PRIMERS ON FLOOR DRAINS IF REQUIRED BY LOCAL PLUMBING CODES. 13. ALL FLOOR CLEANOUTS SHALL BE INSTALLED FLUSH WITH FLOOR FINISH MATERIAL OR FLUSH WITH CONCRETE SLAB IF NO FLOOR FINISH MATERIAL IS CALLED OUT FOR ON ARCHITECTURAL DRAWINGS. 14. LOCATE ALL FLOOR CLEAN-OUTS OUT OF TRAFFIC WAYS, WHILE MAINTAINING ACCESSIBILITY. LOCATE PER DIMENSIONS IF SHOWN ON PLANS. 15. FLOOR CUTS SHALL BE STRAIGHT AND CLEAN, REPLACE REMOVED SLAB WITH CONCRETE FLUSH AND SMOOTH WITH ADJACENT FLOOR SLAB. REFERENCE ARCHITECTURAL SHEETS. COORDINATE WITH GENERAL CONTRACTOR. 16. CAP ALL PIPING OPENINGS DURING CONSTRUCTION UNTIL FINAL CONNECTIONS TO EQUIPMENT AND ACCESSORIES ARE MADE.
UNION
HOSE BIBB (HB) NON-FREEZING WALL HYDRANT (NW)
INSTALL PLUMBING FIXTURES AT THE MOUNTING HEIGHTS SHOWN ABOVE UNO IN THE ARCHITECTURAL DRAWINGS OR ELSEWHERE IN THE CONSTRUCTION DOCUMENTS. FINAL APPROVAL OF LOCATIONS BY ARCHITECT. MOUNTING HEIGHTS LISTED ABOVE, OR ELSEWHERE IN THE CONSTRUCTION DOCUMENTS, ARE AFF, UNO. ALL DEVICES SHALL BE INSTALLED IN COMPLIANCE WITH CURRENT ADA AND LOCAL REQUIREMENTS.
ANNOTATION 1
PLUMBING PLAN NOTE CALLOUT
1
PLUMBING EQUIPMENT DESIGNATION. (CONTRACTOR FURNISHED AND INSTALLED). REFER TO PLUMBING FIXTURE OR EQUIPMENT SCHEDULES
1
CU 1
EQUIPMENT DESIGNATION (OWNER FURNISHED, CONTRACTOR INSTALLED) MECHANICAL EQUIPMENT DESIGNATION (CONTRACTOR FURNISHED AND INSTALLED UNLESS NOTED OTHERWISE) CONNECTION POINT OF NEW WORK TO EXISTING
1 P1
DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER LOWER NUMBER INDICATES SHEET NUMBER
1 P1
SECTION CUT DESIGNATION
CW
DOMESTIC COLD WATER (CW)
SCW
SOFTENED COLD WATER (SCW)
HW
DOMESTIC HOT WATER (HW)
HWR
DOMESTIC HOT WATER RECIRC. (HWR)
140°
DOMESTIC HOT WATER (140°)
T
TRAP PRIMER LINE (T)
S
SOIL PIPING - ABOVE FLOOR (S)
S
SOIL PIPING - BELOW FLOOR (S)
W
WASTE PIPING - ABOVE FLOOR (W)
W
WASTE PIPING - BELOW FLOOR (W)
GW
GREASE WASTE - ABOVE FLOOR (GW)
GW
GREASE WASTE - BELOW FLOOR (GW)
CGWV
COMBINATION GREASE WASTE AND VENT (CGWV)
CWV
COMBINATION WASTE AND VENT (CWV)
ST
STORM DRAIN - ABOVE FLOOR (ST)
ST
STORM DRAIN - BELOW FLOOR (ST)
OST
OVERFLOW STORM DRAIN - ABOVE FLOOR (OST)
VBG
VENT BELOW GRADE (VBG)
VBF
VENT BELOW FLOOR (VBF)
ID
INDIRECT DRAIN (ID)
CDH
CONDENSATE DRAIN - HIGH EFFICIENCY RTU (CDH)
CD
CONDENSATE DRAIN (CD)
ACD
AUXILIARY CONDENSATE DRAIN (ACD)
SPD
SUMP OR SEWAGE PUMP DISCHARGE (SPD)
G
NATURAL GAS (G)
G
NATURAL GAS ON ROOF (G)
MANUAL / AUTOMATIC AIR VENT OR VACUUM RELIEF VALVE
MPG
MEDIUM PRESSURE NATURAL GAS (MPG)
PRESSURE / VACUUM SWITCH
MPG
MEDIUM PRESSURE NATURAL GAS ON ROOF (MPG)
CLEANOUT (CO)
NPW
NON-POTABLE WATER (NPW)
CAP
LPG
LIQUEFIED PETROLEUM GAS (LPG)
WALL CLEANOUT (WCO)
WS
WATER SERVICE (WS)
FLOOR CLEANOUT (FCO)
FP
FIRE PROTECTION (FP)
EXTERIOR CLEANOUT (ECO)
PD
CONDENSATE PUMP DISCHARGE (PD)
ELBOW UP
V
VENT PIPING (V)
ELBOW DOWN
AW
ACID WASTE - ABOVE FLOOR (AW)
TEE UP
AW
ACID WASTE - BELOW FLOOR (AW)
TEE DOWN
AV
ACID VENT (AV)
ELBOW UP WITH SHUT-OFF VALVE (SOV)
GWS
GRAY WATER (GWS)
ELBOW DOWN WITH SHUT-OFF VALVE (SOV)
CA
COMPRESSED AIR (CA)
TEE UP WITH SHUT-OFF VALVE (SOV)
I.W.
IRRIGATION WATER (I.W.)
TEE DOWN WITH SHUT OFF VALVE (SOV)
"A"
WATER HAMMER ARRESTER (WHA) WITH PDI SIZES, (A, B, C, D, & E)
ABBREVIATIONS RECIRCULATION PUMP
17. CUT AND PATCH EXISTING CONCRETE FLOOR SLAB FOR INSTALLATION OF NEW UNDERGROUND PLUMBING PIPE. MATCH EXISTING CONSTRUCTION.
P-TRAP
18. INSTALL CONTINUOUS SEALANT JOINT AT ALL EXTERIOR WALL PENETRATIONS.
TRAP PRIMER
ADA
GAS COCK
TRAP PRIMER WITH DISTRIBUTION UNIT 19. PROVIDE SEISMIC BRACING BASED ON APPROPRIATE SEISMIC ZONE REQUIREMENTS PER SMACNA PUBLISHED SEISMIC DETAILS, LOCAL AND NATIONAL CODES. CONTRACTOR'S RESPONSIBILITY INCLUDES STRUCTURAL ENGINEER'S CERTIFICATION ON DETAILS SUBMITTED FOR PERMITTING.
AFF AFG AHU AP BAS BFF BFG BOP BOS BTU CP CPVC
20. BUILDING COMPONENTS ABANDONED BY THE SCOPE OF WORK SHALL BE SECURED TO PREVENT FALLING, LOOSENING, OR CREATING DAMAGE OF ANY KIND IN THE FUTURE.
CU DI DN DFU DS (E) EMS
LINETYPE LEGEND THROUGHOUT THE DRAWINGS DIFFERENT LINETYPES ARE USED IN COMBINATION WITH THE SYMBOLS TO INDICATE THE STATUS OF ITEMS AS EXISTING, TO BE DEMOLISHED, TO BE INCLUDED AS PART OF NEW WORK AND/OR ITEMS WHICH ARE ANTICIPATED TO BE PROVIDED IN THE FUTURE. THE STATUS OF ITEMS USING THESE LINETYPES ARE RELATIVE TO THE VIEW IN WHICH THEY APPEAR. PHASING SHOWN IN DRAWINGS IS NOT INTENDED TO FULLY DESCRIBE ALL NECESSARY CONSTRUCTION PHASING, WHICH IS DETERMINED BY THE CONTRACTOR AS PART OF THEIR RESPONSIBILITIES. ANY SUCH PHASES DESCRIBED IN THE CONSTRUCTION DOCUMENTS ARE GENERAL AND ONLY INTENDED TO INDICATE A BROAD ORDER FOR THE SAKE OF DESCRIBING THE PROJECT. THE FOLLOWING LINETYPES MAY BE USED ON ANY DEVICE, EQUIPMENT, NOTE, LINE, SHAPE, ETC.
EXISTING DEMOLISH
NEW
ETR EWC FD FFA FFB FF FL FLA FLR GPM HD HZ IE IN WC JB J-BOX KW MAU MAX MBH MH
AMERICANS WITH DISABILITIES ACT ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDLING UNIT ACCESS PANEL BUILDING AUTOMATION SYSTEM BELOW FINISHED FLOOR BELOW FINISHED GRADE BOTTOM OF PIPE BOTTOM OF STRUCTURE BRITISH THERMAL UNIT CONDENSATE PUMP CHLORINATED POLYVINYL CHLORIDE COPPER DUCTILE IRON DOWN DRAINAGE FIXTURE UNIT DOWNSPOUT EXISTING ENERGY MANAGEMENT SYSTEM EXISTING TO REMAIN ELECTRIC WATER COOLER FLOOR DRAIN FROM FLOOR ABOVE FROM FLOOR BELOW FINISHED FLOOR FLOW LINE FULL LOAD AMPS FLOOR GALLONS PER MINUTE HEAD, HUB DRAIN HERTZ INVERT ELEVATION INCHES OF WATER COLUMN JUNCTION BOX JUNCTION BOX KILOWATT MAKE-UP AIR UNIT MAXIMUM 1000 BTU PER HOUR MANHOLE
MIN N/C N/O NIC ORD PDI PH/Ø PRV PVC RCP RD RPM RTU SF SP SS TDH TFA TFB TYP UL UNO UPS VCP VFD VS VTR W/ W/O WC WS WSFU WVS
MINIMUM NORMALLY CLOSED NORMALLY OPEN NOT IN CONTRACT OVERFLOW ROOF DRAIN PLUMBING DRAINAGE INSTITUTE PHASE PRESSURE REDUCING VALVE POLYVINYL CHLORIDE REINFORCED CONCRETE PIPE ROOF DRAIN REVOLUTIONS PER MINUTE ROOFTOP UNIT SQUARE FEET SUMP STAINLESS STEEL SANITARY SEWER, SOIL STACK TOTAL DYNAMIC HEAD TO FLOOR ABOVE TO FLOOR BELOW TYPICAL UNDERWRITERS LABORATORIES, INC. UNLESS NOTED OTHERWISE UNINTERRUPTIBLE POWER SUPPLY VITRIFIED CLAY PIPE VARIABLE FREQUENCY DRIVE VENT STACK VENT THROUGH ROOF WITH WITHOUT WATER COLUMN WASTE STACK WATER SUPPLY FIXTURE UNIT WASTE VENT STACK
3297 Route 66, Neptune, NJ 07753 t:732.918.2300 f:732-898-7848
FLOOR SINK (FS), SIZE & TYPE
THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF PRELIMINARY SUBMITTAL STEVEN A. NEVILLE LICENSE # 138452 IT IS NOT TO BE USED FOR CONSTRUCTION PURPOSES
SEAL
REVISIONS:
CHECKED BY:
GEH
DRAWN BY:
GCC
8001-P001-PLUMBING GENERAL NOTES AND LEGENDS
2/22/2023 4:08:30 PM Autodesk Docs://300-22-003 Spring TX/300-22-003 Spring, TX_Central Fill Station_MEP.rvt
DOCUMENT DATE:
STEVEN A. NEVILLE
JOB NUMBER: 2250004519
30"
2250004519 TX. CORPORATE NO: F-001236 EXPIRES 9/30/2023
CLINIC SERVICE SINKS (RIM)
WWW.HENDERSONENGINEERS.COM
PROVIDE ALL MATERIALS FOR A COMPLETE INSTALLATION IN ALL RESPECTS AND READY FOR INTENDED USE AND IN STRICT ACCORDANCE WITH STATE AND LOCAL CODES AND MANUFACTURERS RECOMMENDATIONS.
STORE NO. STORE NO: XXXX-XXX
2.
SPRING, TX
GENERAL NOTES ARE APPLICABLE TO ALL PLUMBING DRAWINGS.
8345 LENEXA DRIVE, SUITE 300 LENEXA, KS 66214 TEL 913.742.5000 FAX 913.742.5001
PIPING LINETYPES
1.
THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT SPRING, CONTEMPORARANEOUSLY WITH ITS ISSUE DATE ON 02/24/23 , AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.
V2.02
Gabriel J. Massa, RA, AIA, NCARB, LEED AP TX License No: 16849
THIS IS A MASTER LEGEND AND NOT ALL SYMBOLS OR ABBREVIATIONS ARE USED. STANDARD MOUNTING HEIGHTS PIPING SYMBOLS
CONSULTANTS
12.20.13
PLUMBING SYMBOLS
STIPULATION FOR REUSE
GENERAL NOTES
02/24/23
PLUMBING GENERAL NOTES AND LEGENDS
SHEET:
P001