28
SECURITY ENERGIZER
Installation and User Manual
Edition 2.3, July 2019
JVA ELECTRIC FENCE SYSTEMS
JVA Z Energizer Range Concept
JVA ELECTRIC FENCE SYSTEMS Thank you for choosing our product. The JVA brand is a range of electric fencing products carefully selected from leading manufacturers around the world to meet the needs of perimeter security.
THE JVA Z RANGE ENERGIZER CONCEPT The JVA Range of Energizers has been collaboratively designed and manufactured by an international team with over 30 years of electric fence experience earned in some of the most testing security environments in the world. It aims to provide the very best low-cost, high-voltage security energizers in the world. They are compact, integrated and fully programmable electric fence energizers with built-in alarm units and LCD out and return voltage display. They also have the option of being controlled from a remote LCD keypad. State-of-theart energizer design IP4 x and ABS plastic
Unique LCD display depicting fence out and return voltage
Unique LCD keypad option depicting fence and alarm condition
2-RyANrTY
WAR
Wall-mountable, robust energizer housing with easily detachable PCB chassis for ease of installation and repair
TWO-YEAR WARRANTY All JVA products carry a 2-year warranty against defective components and workmanship. The warranty excludes damage caused by acts of Nature such as lightning or flooding, power supply surges, rough handling, malicious action or incorrect wiring.
Please retain your invoice as proof of purchase and fill in the warranty form on page 39.
JVA ELECTRIC FENCE SYSTEMS
CONTENTS 1. INTRODUCTION ....................................................................................... 3 2. FEATURES ................................................................................................ 4 2.1 Power ............................................................................................... 4 2.2 Control / Monitoring .......................................................................... 4 2.3 Safety ............................................................................................... 4 2.4 Reliability .......................................................................................... 4 3. SPECIFICATIONS ..................................................................................... 5 4. DESCRIPTION .......................................................................................... 6 JVA Z28 Exterior ............................................................................... 6 JVA Z28 – High Voltage Terminals ................................................... 6 LCD Voltage Display ........................................................................ 7 Status LED Lights ............................................................................. 8 Inputs and Outputs ........................................................................... 8 4.5.1 Relay Functions .................................................................... 9 4.6 4-line LCD Keypad ........................................................................... 10 4.7 Internal Beeper / Keypad Beeper ..................................................... 22 4.8 Cabling ............................................................................................. 22 4.9 Lightning Protection .......................................................................... 22 4.10 Earth Loop Monitoring ...................................................................... 22 4.11 Noise and Interference ..................................................................... 22 4.12 Programmable Options .................................................................... 22 4.13 Low Power Mode .............................................................................. 22 4.14 Control Inputs ................................................................................... 23 4.14.1 Control Inputs ....................................................................... 23 4.14.2 Control Input Functions ........................................................ 23 4.14.3 Keyswitch Inputs .................................................................. 23 4.15 Simultaneous Pulse Feature ............................................................ 23
Contents
4.1 4.2 4.3 4.4 4.5
5. INSTALLATION .......................................................................................... 24
JVA recommends installation by qualified technicians 5.1 Installation Steps .............................................................................. 24 5.2 Example Fence Wiring Diagrams ..................................................... 25
1
JVA ELECTRIC FENCE SYSTEMS 6. OPERATION .............................................................................................. 27 6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8 7.
Arm / Disarm Control ........................................................................ 27 Arming the Fence Using the Keypad ................................................ 27 Turning to Low Power Mode ............................................................. 27 When an Alarm Occurs .................................................................... 27 To Silence the Alarm ......................................................................... 28 Changing the PIN number ................................................................ 28 Standby Battery ................................................................................ 28 Status Light ...................................................................................... 28
TECHNICAL INFORMATION ..................................................................... 29
Contents
8.1 Power Options .................................................................................. 29 8.2 Status Codes .................................................................................... 30 8.3 Jumpers ............................................................................................ 30 8.3 Multiple Keypads .............................................................................. 30 8. 9.
GROUP MODE .......................................................................................... 31 SECTOR SETUP TESTS AND ADJUSTMENT ......................................... 34 9.1 Basic Fence Tests ............................................................................ 34 9.2 Fault Condition Tests ....................................................................... 34
10. Some Standard Requirements FOR ELECTRIC SECURITY FENCES ................................................................................. 35 10.1 Definitions ......................................................................................... 35 10.2 Installation, Operation and Maintenance .......................................... 35 10.3 Warning signs ................................................................................... 36 10.4 Gates ................................................................................................ 36 10.5 Earthing ............................................................................................ 36 10.6 Protection ......................................................................................... 37 11. WARRANTY .............................................................................................. 39 12. COMPLIANCE CERTIFICATE ................................................................... 40
2
JVA ELECTRIC FENCE SYSTEMS
1. INTRODUCTION Welcome to the world of JVA monitored electric security fences. The proliferation of non-lethal, monitored, electric security fences in our towns and cities is indicative of the confidence the public has in this form of perimeter security. The reason for this popularity is simple – monitored electric security fences are effective, economical, simple to install, and they offer more D’s of security than any other perimeter system:
Every second, the JVA Z energizer discharges a very short-duration, safe, high-voltage pulse down the fence live wire. The JVA Z energizer then monitors the voltage at the end of this live wire, thereby checking that the voltage is being maintained along the entire fence line. In the event of a voltage drop caused by either shorting, cutting or poor maintenance, the monitor will trigger an alarm, thus alerting you.
Introduction
Demarcation – The JVA fence around your property shows you mean business. Deflection – Would-be intruders will be deflected to softer targets. Deterrence – The safe, powerful JVA shock is a strong deterrent to intruders. Delay – The physical barrier will delay an intruder, something they do not like. Detection – The JVA’s voltage monitor warns you of any tampering with the fence. Deny – A well-erected electric security fence will deny entry. Dependable – 60 seconds a minute, 60 minutes an hour, 24 hours a day, 365 days a year, your JVA electric security fence is monitored by an alert, sober, electronic watchman.
Manufactured to meet the most stringent international safety standards, the JVA Z energizer is in a class of its own when it comes to features and benefits at an affordable price.
An electric fence system which meets current safety regulations
3
JVA ELECTRIC FENCE SYSTEMS
2. FEATURES 2.1 Power ● 8 joules peak output energy (4 + 4 Joules = 8 Joules total) ● Mains powered via external transformer (16–18Vac) ● Battery charger with space for internal 7A/H 12V rechargeable back up battery
Note: A 9 A/h battery may be used as it is the same size as a 7 A/h battery
2.2 Control / Monitoring ● 3 Control inputs which can be configured to take N.O. or N.C. control contacts. ● 3 12V driven outputs (also referred to as relays), high side switched (common
negative)
● All relays may be assigned to any alarm function
Features
● LCD voltage display ● LED status lights ● Internal beeper ● AC fail, Low Battery and Bad Battery detection ● Keypad programmable options ● Low power mode – ensures detection together with public safety during the day ● Adjustable energizer power output level
2.3 Safety ● Designed to pass IEC60335.2.76 and EMC standards (reports available on
request)
● Enclosed fence terminals ● Wall mountable, robust enclosure with detachable PCB chassis for ease of
installation and repair
2.4 Reliability ● Microprocessor controlled. ● Pluggable screw terminals ● State of the art, robust, case design IP4x ABS ● Built-in lightning protection from both mains and fence sides, external fence
lightning protection is still advised in high lightning prone areas
● All inputs and outputs protected against stray fence voltage
4
JVA ELECTRIC FENCE SYSTEMS
3. SPECIFICATIONS Specification
Energizer Output Voltage
8.5kV peak no load
Peak Output Energy
2 × 4 Joules
Pulse Rate
Locked at 0.9 Hz
12v DC Power Consumption
Energizer On – 1005mA average, 1220mA peak Energizer Off – 28mA Not including keypad or Auxiliary power
AC Power Input
16-18Vac 1.5A*
Battery Charger Output
Float voltage 14V, 700mA, short circuit protection, reverse battery protection
Switched Outputs
Three 12V 2.5A maximum combined load powered output.
Recommended Operating Temperature
–15°C to +50°C
Enclosure
IP4x ABS Plastic
Size
300mm high, 190mm wide, 115mm deep
Weight – packed, no battery
2.5kg
* A 24Vdc 1.5A supply can be used in place of the 16Vac. The correct connection is +24V to the right AC pin, GND to the left AC pin. Due to the stored energy in a 24Vdc plug-pack, an AC Fail could occur 5 minutes before the Energizer reports this fault
Specifications
Specification Name
• There are no user-serviceable parts in this unit. • There are potentially lethal high voltages inside the Z Series energizers. • The high voltage inside the Z Series Energizers may take a long time to discharge. Wait at least 10 minutes after turning off before opening the case.
WARNING
• Before working on the high voltage wiring of an electric fence, it is recommended that the energizer be disarmed and an intentional short circuit is placed from the fence live wires to earth. This is a sensible precaution against the energizer being turned on by others or malfunctioning while working on the fence. • If an electric fence is part of a multiple energizer system and the distance between two separate electric fences, each powered by separate energizers, is less than 2.5 meters, the energizers must be configured to operate in group mode.
5
JVA ELECTRIC FENCE SYSTEMS
4. DESCRIPTION The Z28 is a dual channel standard (non Bi-Polar) 8 Joule (4 per channel) security energizer. This manual relates to: ● PCB versions: 7.51 and higher ● Firmware versions: 7.50 or higher (the firmware version is shown on the LCD on reset)
9.2 9.0
Description
4.1 JVA Z28 Exterior
Figure 1: Z28
4.2 JVA Z28 – High Voltage Terminals ZONE 2 RETURN
6
EARTH RETURN
ZONE 1 RETURN
ZONE 2 OUT
EARTH
ZONE 1 OUT
Figure 2: Output Terminals
JVA ELECTRIC FENCE SYSTEMS 4.3 LCD Voltage Display The display on the JVA Z28 shows the voltage at the feed out and return terminals. Left side = Return zone 1, Right side = Return zone 2. The Stored Joules will be displayed every approximately 4–5 seconds. The reading will vary depending on the load on the fence. Stored Joules displayed is the current stored joules to generate the output voltage as programmed. If the fence is in good condition, this value will be low. As more load comes onto the fence, the amount of joules will increase to meet the requested voltage. The LCD also shows the programming option and current setting when in programming mode. This allows the programming options settings to be checked easily.
–
RETURN HV
–
ZONE 2
Description
ZONE 1
Figure 3: LCD Display and Status LEDs
7
JVA ELECTRIC FENCE SYSTEMS 4.4 Status Lights Left side Z28 Armed 1
On when Zone 1 of the energizer is armed (pulsing), will flash when in low power mode.
Fence 1
Flashes if the return voltage falls below the Fence Alarm Voltage, stays on when there is a Zone 1 fence alarm.
Gate 1
Flashes Red when the Gate is open, stays Red when there is a Gate 1 alarm.
Description
Right side Z28 Power
On whenever the energizer has power.
Armed 2
On when Zone 2 is armed (pulsing), will flash when in low power mode.
Fence 2
Flashes if the return voltage falls below the Fence Alarm Voltage, stays on when there is a Zone 2 fence alarm.
Gate 2
Flashes Red when the Gate is open, stays Red when there is a Gate 2 alarm.
Status
Flashes an error code for energizer (service) errors. See the table in section 7.2 Status LED Error Codes.
NOTE: Fence and Gate LEDs are latched on (like the strobe) until cleared using the clear alarm memory sequence (*1#) or the Energizer is re-armed.
4.5 Inputs and Outputs
16VAC Output Feed terminals
Output Return terminals
Keypad Control Control Inputs Outputs 16VAC Only!
Figure 4: Connection Terminals
8
JVA ELECTRIC FENCE SYSTEMS 4.5.1 Relay Functions All relays can be set to any of the available functions (user assignable). Relay 1 is (21x#) Relay 2 is (22x#) etc. The modes are explained in the table below. The defaults for the Z28: Relay 1 Strobe 1 Relay 2 Strobe 2 Relay 3 Siren. Value (x)
Mode Zone 1 Zone 1 or Disarmed
2
Armed 1
3
Zone 2
4
Zone 2 or Disarmed
5
Armed 2
6
Zone 1 or Zone 2
7
General
8
Siren
9
Strobe 1
10
AC Fail
11
Low/Bad Battery
13
Strobe 2
14
Gate 1 or 2
15
Siren caused by Gate 1 or 2
16
Armed in Low Power Mode
17
Group Armed (Note 3)
18
Group General
Description
0 1
Relay Functions Notes: 1. These defaults were different in pre 7V64 firmware. 2. The siren and strobe switched 12V outputs can be used to drive external buffer relays. 3. Group relay functions are only operable on the group master.
9
JVA ELECTRIC FENCE SYSTEMS 4.6 4-Line LCD Keypad (PTE0240) Introduction The JVA 4-Line LCD Keypad is an integral component in the JVA Security Electric Fence product range. Providing a centralised interface between the Customer and their Perimeter Security Solution; it displays the current condition of each security device connected and can draw attention to adverse fence conditions. The keypad is used to control individual fence Energizers, Monitors or the entire site. The Customer has access to all of these features via a Menu Driven system or by entering key sequences. Security Installers also use the keypad to configure the JVA Security devices to the customer’s needs. Features and Benefits
Description
The PTE0240 LCD keypad is a second generation Z-Series Keypad •
Menu driven interface
•
4-line Backlit LCD display
•
Quick arm / disarm keys
•
500-entry Event-Log
•
Battery-Backed Real Time Clock
•
Control, monitor and program any Z-Series device
•
Displays arm/disarmed status and any trouble or alarm
•
Shows fence voltages for Z-Series electric fence energizers and monitors
•
Programmable zone names
•
Key area glows red on alarm
•
Event Log stores Date and Time of Alarm or Trouble
Limitations 1. The Menu-driven programming requires 8v20 or higher firmware in Energizers. 2. As the firmware is upgraded from time to time, an older keypad may not be compatible with the latest Z-Series devices. The firmware version can be seen by pressing *9#.
10
JVA ELECTRIC FENCE SYSTEMS Opening the Keypad Push the 4 side tabs in to release the cover from the base. This can be done one side at a time. Once the cover has been removed from the base plastic, the keypad hardware will slide up to release it from the base.
The Keypad only requires three wire connections to JVA Energizers or Monitors. This is the +12V, GND and DATA connections on the back of the Keypad circuit board.
Description
Installation
11
Description
JVA ELECTRIC FENCE SYSTEMS
When connecting a Group of Energizers together, the +12V wire is only required between the Keypad and Energizer. The other Energizers are connected together using the GND and DAT terminals only.
Keypad terminals on a JVA Single Zone Energizer
Keypad Operation Note: Z-Series Energizers/Monitors have the following Default PINs User PIN: 1234 Installer PIN: 012345 Discovering Energizers Function Discover Devices connected to the Keypad
12
Key 1
Key 2
Key 3
Key 4
*
6
8
#
JVA ELECTRIC FENCE SYSTEMS The Keypad needs to discover all of the Energizers/Monitors connected to the Keypad for it to work properly. This is best achieved after each Energizer/Monitor has been configured and wired together in a group. The display will show “Analysing” followed by the device type connected at each zone. NOTE: All Energizers/Monitors need to be Disarmed before starting the Discovery process. Arming/Disarming the Site Using the Keypad To Arm the site, press the Lock button. It will ask for your PIN. Enter the USER PIN and press # To Disarm the site, press the Un-Lock button. It will ask for your PIN. Enter the USER PIN and press #
Press the # key on the Menu item “Silence Siren” A short-cut for this is to just enter 1470# directly. Keypad Status Display In normal operation the keypad shows a Summary Page followed by the status of each device connected to the Keypad. Summary page:
Z14 page:
JVA Security 13:17 01/11/2015 Disarmed All OK ZONE 1 Feed:8.6kV Ret:7.5kV Alarm: Fence
Description
To Silence a Siren on an Energizer/Monitor press the Menu Button. It will ask for your PIN. Enter the USER PIN and press #
The Installer’s Details (Dealer Message) 24hr Clock and Date If the site is Armed/Part Armed or Disarmed If the site is in Alarm/Trouble or All OK The Name of the Zone (Zone Label) The Energizer Voltages Alarms/Troubles are displayed here
The keypad will automatically scroll the display through all relevant information on each connected Energizer/Monitor. Each screen is shown for about 5 seconds. To pause this, press # and the auto scrolling will stop for 20 seconds. Pressing the # key again will advance the display one step.
13
JVA ELECTRIC FENCE SYSTEMS The keypad will automatically display a new Zone Alarm or Trouble and it will remain on this page for 3 minutes. Pressing # again will advance the screen. If the Keypad beeper is sounding, any key press will silence it. Keypad Menu The Keypad Menu system can be accessed by pressing the Menu key. Key in either the USER PIN or INSTALLER PIN followed by the Enter key to proceed. To access the Menu items below Exit Menu the Installer PIN is required.
Description
Main Menu Menu
Function (when # key is pressed)
Mute Siren
Mutes Energizer or Monitor Sirens currently sounding
Clear Alarms
Sends the Clear Alarm Memory command to the Energizers/Monitors. This will clear “Latched Fence Alarms� if the problem has been cleared.
Show Event Log
Displays the Event Log. Use Up/Down keys to scan through events. The # key will exit the Log
Arm Low Power
Arm the Site in Low Power Mode
Arm High Power
Arm the Site in High Power Mode
Test Menu
See Test Menu
Keypad options
See Test Menu Menu
Function (when Enter key is pressed)
Analyse group
Discovers the Energizers connected to the Keypad
Siren Test
Turns on the Energizer/Monitor Siren Outputs for 2 seconds
Battery Test
Triggers the Battery Test in connected Energizers/Monitors. See the LCD display of the Energizer for the results.
Show Model
Displays the Keypad Version
Reset Energizers
Forces the Energizers to reset
Keypad Options Set Clock
14
Displays the current clock for editing. See Event Log. The Event log contains information about Alarms, Troubles and Arm/ Disarm commands. Each event is displayed on a separate page. Press the Up or Down key to change pages. Press # to exit the Log. The most recent entry is displayed when the log is first opened. Setting the Clock
JVA ELECTRIC FENCE SYSTEMS
Menu
Function (when # key is pressed)
Show Shortcuts
Displays commonly used Key Sequences for reference
Remember User PIN /
This will ‘save’ the USER PIN entered. From now on, the Quick Arm/ Disarm buttons will not require a PIN to operate. Pressing Menu button immediately enter the Menu system as well.
Forget User PIN Exit Menu
Delete the ‘saved’ USER PIN Exits the Keypad Menu
Program Device Program Sectors Clear Log
Requires Installer PIN to access. Clears the Event Log
Program this Keypad
Requires Installer PIN to access. See Program Device: Requirements for Menu Driven Programming
Procedure The Keypad takes around 10 seconds to enter Menu Driven Programming mode. Once entered, the list of connected devices will be listed. Use the Up/Down arrow to choose the device to be configured. Press # and the Keypad will Load the configuration from the Energizer. Use the Up/Down arrows to move around the options and the Left/ Right arrows to change the selected value.
Description
For this system to work effectively, all connected Energizers/Monitors need to be Mk2 protocol compliant. This version is usually found in the Black Plastic box, rather than a Silver Plastic box.
Options with >> displayed have a SubMenu that is accessed by pressing the Right Arrow. Use the Up/Down arrows to select the new options and Left/Right to change the selected value. To exit this SubMenu, press the Up arrow till the cursor is at the << line. Now press the Left Arrow. Press # at any time to Save the new configuration to the Device. Press * at any time to Discard the configuration. Exiting Device Programming Press the Menu at any time to completely exit Device Programming. Program Sectors Program this Keypad Default Keypad
Returns the keypad to Factory Defaults
15
JVA ELECTRIC FENCE SYSTEMS Event Log The Event log contains information about Alarms, Troubles and Arm/Disarm commands. Each event is displayed on a separate page. Press the Up or Down key to change pages. Press # to exit the Log. The most recent entry is displayed when the log is first opened.
Log Entry: 37 14:35 13/02/15 Zone 1 Fence Alarm
Setting the Clock The clock is formatted to 24 hour time followed by the Day/Month/Year.
Set Time and Date hh:mm dd/mm/yy 14:35 13/02/15 --:-- --/--/--
Description
Use the number keys to set the new value for the current cursor location. Each number pressed will move the cursor to the right. If the keypad detects an error, the cursor will return to the first location and the original date time will be displayed again. The entire Time and Date needs to be entered before the new value is saved. Pressing the Enter Key at any time during the process will cancel the update. Test Menu Menu
Function (when Enter key is pressed)
Analyse Group
Discovers the Energizers connected to the Keypad
Siren Test
Turns on the Energizer/Monitor Siren Outputs for 2 seconds
Battery Test
Triggers the Battery Test in connected Energizers/Monitors. See the LCD display of the Energizer for the results
Show Model
Displays the Keypad Version
Reset Energizers
Forces the Energizers to reset
Keypad Options
16
Menu
Function (when Enter key is pressed)
Press Beeps
Turns ON/OFF the key press beeps
Chime Sounds
Turns ON/OFF the Gate Chime Sounds
Error Sounds
Turns ON/OFF the Error Sounds when entering a PIN for Energizer control
Alarm Sounds
Turns ON/OFF the Keypad Beeper sounding for a new Alarm/Trouble
Backlight
Cycles through the Backlight options (ON / Timeout / OFF)
JVA ELECTRIC FENCE SYSTEMS Program Device Requirements for Menu Driven Programming For this system to work effectively, all connected Energizers/Monitors need to be Mk2 protocol compliant. This version is usually found in the Black Plastic box, rather than a Silver Plastic box. Procedure The Keypad takes around 10 seconds to enter Menu Driven Programming mode. Once entered, the list of connected devices will be listed. Use the Up/Down arrow to choose the device to be configured. Press # and the Keypad will Load the configuration from the Energizer.
Select Device... ID: 1-Z25 ID: 2-Not Connected ID: 3-Z18 High Power Low Power Fence 1 Alarm Fence 2 Alarm
8.5 1.1. 4.0 4.0
Options with >> displayed have a SubMenu that is accessed by pressing the Right Arrow. Use the Up/Down arrows to select the new options and Left/Right to change the selected value.
Unused Group ID Input 1 Input 2
1 >>. >>
To exit this SubMenu, press the Up arrow till the cursor is at the << line. Now press the Left Arrow.
Description
Use the Up/Down arrows to move around the options and the Left/Right arrows to change the selected value.
<< Input 1 . Trigger N/Open Function Arm All
Press # at any time to Save the new configuration to the Device. Press * at any time to Discard the configuration. Exiting Device Programming Press the Menu at any time to completely exit Device Programming.
17
JVA ELECTRIC FENCE SYSTEMS Program this Keypad This menu allows the Zone names, and Dealer/Service messages to be altered. It also contains the Keypad Address. The menu order is:
• • • • •
SERVICE MESSAGE DEALER MESSAGE ZONE NAMES (1 – 16) BAUD RATE KEYPAD ADDRESS
Description
The Dealer Message, Service Message and each of the 16 Zone Labels can be changed using a Multi- Touch Entry System •
The Dealer Message is displayed on the Summary page
•
The Service Message is displayed on the Summary page during AC failure, communication failure, or low battery
•
Zone Labels are displayed at the top of each Device Page.
The keypad will also exit the programming mode if you do not press any key in five minutes. Key values (Multi-Touch Entry)
“See Below” – The Zero key has the following characters: space 0 . ! @ # $ % ^ & * ( ) - + The Multi-Touch entry system is based on the system older mobile phones used for text entry. Pressing a key more than once will change the character based on the values assigned to that number. When the correct letter is displayed, either press a different Key or Pause for 2 seconds before pressing the same Key.
18
For example: To enter the letter R, you would press Key 7 three times. To enter JVA, you would press 58882 To enter ACE, you would press 2 (pause for 2 seconds) 22233
JVA ELECTRIC FENCE SYSTEMS Changing the Keypad Number options (Arrow Keys)
The Keypad BAUD and Keypad ID options can be changed using the Up/Down Arrow Keys. Press # when the correct value has been selected. Pressing the * key will discard any changes and the display will show the previous option.
Group Connection Function Re-analyse the keypad group
Key 1 Key 2 Key 3 Key 4 Key 5 Key 6 Key 7 Key 8 USER PIN
*
6
8
#
Up to three keypads may be used to remotely monitor and control Z-Series devices. To operate correctly, each keypad must be configured to use a unique keypad address. This is achieved by connecting one keypad (at a time) to the master Z-Series device and updating the keypad address. Once all keypads have a different address, all can be connected to the system. A recommendation is that one keypad is kept at address 1.
Description
Using more than one Keypad
If the security system is to use a PC based interface such as Perimeter Patrol, keypad address 2 should not be used by a keypad. The PC software uses this address to control the Z-Series devices. Once all Keypads are connected, enter the Re-analyse the keypad group command listed above.
Notes Things to remember when configuring/using the keypad. • • •
Zone 1 must be connected to the group. If it is not connected, the other Z-Series devices in the group will not send their data to the keypad generating Coms Fail alarms on the keypad. If the keypad is unresponsive, this is likely due to the Z-Series device looking for other keypads in the group. Be patient. Wait a few seconds and try again. A slave Z-Series device disconnected from the Group will only talk to a keypad if it has a keypad address of 1 or 8.
19
20
Energizer Function Arm/Disarm Silence the Energizer Siren Start Programming the Z-Series energizer Start Programming the Keypad Exit Programming (any mode) Change a User PIN, 4 Digits Change the Installer PIN, 6 Digits NOTE1 Arm All Zones (Multi-zone groups) Arm Specific Zone (up to Zone 15) Disarm All Zones Disarm Specific Zone (up to Zone 15) Switch All Zones to low power mode Switch Specific Zone to low power mode Switch All Zones to high power mode Switch Specific Zone to high power mode Arm Gate circuits only Bypass Siren (All Zones) Bypass Specific Zone Siren Re-enable Siren (All Zones) Re-enable Specific Zone Siren Bypass Gate Alarm (All Zones) Bypass Specific Gate Alarm Re-enable Gate Alarm (All Zones) Re-enable Specific Gate Alarm
Default INSTALLER PIN 012345 Default USER PIN 1234
0
*
1
Key 1
1 1 2 2 4 4 4 4 4 5 5 5 5 5 5 5 5
0
Key 6
0 0
Key 8
# 1
Key 9
#
#
#
#
#
#
# #
Key 10 Key 11 Key 12
NEW USER PIN # 0 # Zone Number # 0 # Zone Number # 1 # 1 Zone Number 2 # 2 Zone Number # 2 # 2 Zone Number 1 # 1 Zone Number 4 # 4 Zone Number 3 # 3 Zone Number
#
* *
Key 7
1. To change the Installer PIN, the Energizer needs to be in Energizer Programming Mode first. (“Start Programming the Z-Series energizer” function)
Key 2 Key 3 Key 4 Key 5 USER PIN # 4 7 0 # INSTALLER PIN INSTALLER PIN # USER PIN * 0 NEW INSTALLER PIN USER PIN * USER PIN * USER PIN * USER PIN * USER PIN * USER PIN * USER PIN * USER PIN * USER PIN * USER PIN * USER PIN * USER PIN * USER PIN * USER PIN * USER PIN * USER PIN * USER PIN *
Summary of Keypad Key Sequences
Description
JVA ELECTRIC FENCE SYSTEMS
6
*
* * *
Backlight mode On/Timeout/Off
Display Keypad Model
*
Keypad Error Tones On/Off
Local Keypad Alarms On/Off
* *
Keypad Audible Feedback On/Off
Change the Keypad Messages to Spanish
Keypad Chimes On/Off
* *
Change the Keypad Messages to English
Keypad Specific Function
Panic – The Energizer/Monitor will react depending on its Panic settings Key 1
6 6
* *
Battery test
Display the Stored Joules
Re-analyse the group
6
* *
Display the Group ID of the Energizer
Siren test
9
8
5
5
5
5
3
3
Key 2
2
1
*
Key 2
Key 1
Energizer Function
Clear Alarm memory
#
#
5
4
3
1
2
1
Key 3
#
8
7
4
3
6
#
Key 3
#
#
#
#
#
#
Key 4
#
#
#
#
#
Key 4
INSTALLER PIN
Key 4 *
*
Key 5
Description
Reset and return to factory defaults
USER PIN
Key 3
Reset and Display firmware version number
Key 2 USER PIN
Key 1
Arm in Agricultural Mode (No Alarms)
Energizer Function 6
9
Key 6
Key 8 # 6
8 *
Zone Number
Key 7
8
#
Key 9
#
Key 10 Key 11 Key 12
JVA ELECTRIC FENCE SYSTEMS
21
JVA ELECTRIC FENCE SYSTEMS 4.7 Internal Beeper/Keypad Beeper Depending on the chime mode setting, the internal beeper and keypad beeper will sound when there is a fence alarm, a gate alarm or a general alarm or a door chime. On flat battery the keypad will always beep 4 times before the energizer automatically enters low voltage mode to preserve the battery. On AC Fail it will beep.
4.8 Cabling High voltage cabling (fence lead out and returns) should be run using suitably rated cable. Double insulated electric fence underground cable is suitable. High Voltage Cables must never be run within the same conduit as Low Voltage Cables. A minimum distance of 30mm should be kept between High Voltage and Low Voltage cables.
4.9 Lightning Protection
Description
Although the Z28 contains internal lightning protection elements, external lightning protection elements such as additional external lightning kits available from your local dealer, are recommended as they would help to reduce lightning damage even further.
4.10 Earth Loop Monitoring The Z28 has two fence earth terminals which when wired into a series looped fence system enable the energizer to monitor the earth circuit. In this configuration, only one earth spike location must be used. If this is not required the installer can loop the two earth terminals at the energizer and then connect the earth spikes to one of the parallel earth terminals.
4.11 Noise and Interference The Z28 contains a microprocessor. Extreme electrical noise can upset microprocessors. The most likely cause of such noise is the high voltage output from the unit itself. In the event of erratic behaviour, check that the high voltage wiring is firmly connected to the terminals and that no sparking is seen. The Z28 is designed to self-recover from interference, powering off (both AC and battery) should not be necessary.
4.12 Programmable Options The Z28 has many programmable options. These are also known as setup parameters. To alter these options a keypad must be used. The options are explained in the 4 line keypad section on page 20. Each parameter has a factory set default.
4.13 Low Power Mode
22
Z28 energizers can be switched into low power mode. Low Power mode may be used in situations where the fence is not required to be a deterrent but is still required to actively detect intrusion. In Low Power mode the fence live wires operate at a much lower voltage, typically 900V peak. See Programming Options on page 20 for details on using the keypad to set low voltage mode.
JVA ELECTRIC FENCE SYSTEMS 4.14 Control Inputs 4.14.1 Control Inputs The Z28 has 3 control inputs. These default to: Input 1 – Arm/Disarm Input 2 – Gate 1 Input 3 – Gate 2 or low voltage mode input. The gate inputs may be wired to a gate switch to trigger an alarm when a gate is opened. If the unit is disarmed, the gate input may be set to chime mode. See Programming Device on page 17. NOTE: If not used, the Gate 1 and Gate 2 inputs must be bridged to the Com terminal. Inputs 2 and 3 can be configured for other functions. See Programming Device on page 17.
On/Off (Arm/Disarm) When configured as an On/Off Input, the Control Input Arms or Disarms the Fence Zone. On/Arm will make the Fence Live (High Voltage on the Fence), while Off/Disarm will make the fence Safe (No fence voltage) Gate Input When configured as a Gate Input, the Control Input may be wired to a gate switch to trigger an alarm when the gate is opened for longer than the Gate Entry/Exit Delay time (Option 13). The timer will reset to zero when the gate closes. If the energizer is disarmed, the Gate Input may be set to Chime Mode. See section 9, option 14.
Description
4.14.2 Control Input Functions
High/Low Power Control When configured to control High/Low Power mode, the Control Input is able to change the Energizer Output (While Armed) to either High Power or Low Power modes. It is also used to determine what Power Mode to start in when the energizer is Armed using a Control Input. 4.14.3 Keyswitch Inputs By default one keyswitch is used to arm and disarm both zones. The Z28 can be configured for two keyswitches to arm and disarm individual zones.
4.15 Group Simultaneous Pulse Feature All JVA Z Range models may be linked to form a group to power multiple zones. See Group Mode, page 31.
23
JVA ELECTRIC FENCE SYSTEMS
5. INSTALLATION JVA recommends installation by qualified technicians.
Installation
5.1 Installation Steps 1.
Read the entire manual first!
2.
Design and build the fence. (Beyond the scope of this manual.)
3.
Decide where the JVA Z28 is to be mounted. If on an external wall it should be housed within a waterproof equipment box and definitely not in direct sunlight.
4.
Mount the unit by hanging the housing on the two nail-in anchors provided. If necessary, two extra mounting holes can be used at the bottom of the housing.
5.
If using a keypad, remove the rear housing of the keypad and fix it to the wall.
6.
Wire the low voltage cables to the PCB terminals (right side)*. (See page 8)
7.
Wire the high voltage cable to the PCB terminals*. (See page 8) If earth monitoring is not going to be used on the fence, connect a bridge wire from earth out to earth return.
8.
Fit the battery leads to the battery. The Status LED should blink twice to show mains fail.
9.
Mount the 220 – 16V transformer and connect the 16V side to the Z28 16V input terminals. (AC is not polarity sensitive.) Do not connect a live or neutral to the earth terminal.
10.
The unit is designed not to start when first powered up irrespective of the state of the inputs.
11.
Replace the front cover.
12.
Turn AC power on.
13.
Arm and disarm the energizer via the keyswitch or keypad, if fitted. The Status LED should stop blinking.
14.
If using a keypad, type *68#. The keypad will analyse the zones.
15.
Arm the unit. The LCD display will now show the fence voltage.
16.
Check to ensure that a short anywhere on the fence triggers the alarm.
17.
On handing the system over to the owner/user, explain how to change the user PIN. Leave a User Manual with the user.
*NB Keep high voltage and low voltage cables at least 100mm apart. Do not run high and low voltage cables in the same conduit.
24
JVA ELECTRIC FENCE SYSTEMS 5.2 Example Fence Wiring Diagrams
Feed
Return
Return 2
Earth Return 1 Feed 2 Earth
Feed 1
Installation
Fence 1
Fence 2
Earth spikes
JVA Z28 Energizer Fence Wiring, Including Earth Monitoring
25
JVA ELECTRIC FENCE SYSTEMS
Feed
Return
Return 2
Earth Return 1 Feed 2 Earth
Feed 1
Installation
Fence 1
Fence 2
Earth spikes
JVA Z28 Energizer Fence Wiring, without Earth Monitoring
26
JVA ELECTRIC FENCE SYSTEMS
6. OPERATION 6.1 Arm/Disarm Control The unit can be controlled by the keyswitch, control input 1 or via a keypad. The keypad also allows instant audiovisual indication of the state of the energizer and therefore the fence it is powering. If there are two ways to control the energizer both connected at once, i.e. keypad and control inputs, then the last change will determine the result. So if the unit is armed via the keypad and then disarmed at the control input it will disarm.
6.2 Arming the Fence Using the Keypad ● Enter your USER PIN number (four digits long; default is 1 2 3 4) and push the #
key.
● Make sure the red ARM light comes on. ● The fence will power up and if all is well (no faults) the system will be ready to
deter and detect.
● If there is a fault on the fence and it cannot achieve full voltage, zone 1 or zone 2
LEDs will flash.
● To disarm the system, enter your USER PIN and press #. This will also clear any
fault lights and zone lights which may have been on.
Operation
● The keypad will beep twice to confirm that the system is armed.
6.3 Turning to Low Power mode To switch to Low Power mode, enter your USER PIN and press *41#. In Low Power mode the fence will still be powered and any breach will be detected, but the voltage will be much lower than normal operation. The ARM light will flash in Low Power mode. Enter your USER PIN and press *42# to switch back to Full Power mode. Alternatively, the unit can be switched to Low Power mode using control input 2, if it has been programmed accordingly.
6.4 When an Alarm Occurs If the system is armed and the fence is tampered with, the corresponding Zone Light will flash on the energizer and then remain on. Relays assigned to alarms will turn on. If the energizer is connected to a building alarm system for monitoring, an alarm signal may be sent to the alarm company monitoring the alarm system.
27
JVA ELECTRIC FENCE SYSTEMS An alarm will also sound if input 2 is assigned to the “gate input” function and the gate input is opened and the entry/exit delay time has elapsed. After the siren has cycled on and off according to the times and numbers set in options, the siren will stop sounding. The on and off timing is able to be set in the options. The Strobe will remain on. After a further delay (Auto Rearm Time) the siren will again respond to the next alarm condition with a new set of on / off cycles. If the alarm condition (low fence voltage or gate input) is removed, the siren will stop after the end of the current “on” time (Siren On Time). If the siren is muted by (entering PIN#) then the siren will enter the next “off” cycle (Siren Off Time). If the alarm condition is still present (voltage is low) the siren will sound again after the preset “off” time. If the alarm condition is not present the energizer is instantly rearmed, irrespective of the auto-rearm setting.
6.5 To Silence the Alarm
Operation
● Enter your USER PIN and press #. This will silence the alarm but not disarm the
system; the Armed Light will still be on. If Auto-Rearm is set, the system will be ready for the next alarm. Note that the following functions have an effect on alarm timing: Siren On time, Siren Off time, Siren Cycles, Auto Re-arm time. ● The zone lights on the keypad will flash to show where the breach occurred. ● The siren and strobe are ready to respond again if triggered. ● To disarm the system, enter your USER PIN and press # again. The zone light will remain lit until the Clear Alarm Memory command (*1#) is entered. ● Alternatively, disarming using the key switch will reset the alarm.
6.6 Changing the USER PIN Number
● Enter the old 4-digit USER PIN and press *0#. This enters User Programming
mode.
● Enter your new USER PIN (must be 4 digits) and then #. ● Press *# to exit User Programming mode. ● Make sure your new USER PIN works by using it to arm the energizer. ● The default PIN is 1 2 3 4.
6.7 Standby Battery
Should there be a loss of mains power, the Power Light on the keypad will go off. If the loss of power is prolonged, the battery may discharge power and become ineffective. The Power Light will start to flash indicating a battery low power problem. If the standby battery requires replacement, the Status Light will flash three times.
6.8 Status Light
If the energizer develops an internal fault, the Status Light will flash a code. See section 7.2 (page 30).
28
JVA ELECTRIC FENCE SYSTEMS
7. TECHNICAL INFORMATION
Label
Type
Description
Keypad
3 Way Supplies power and data line for an external keypad. The +12 source on these terminals is protected with a 1A self-resetting fuse.
Inputs
4 Way Energizer control inputs (dry contact). Defaults to normally open. Can be used for a remote switch or a radio receiver. The receiver may be powered from the keypad +12V terminal. See section 4.
Technical Information
Figure 6: Low Voltage Terminals
Outputs 4 Way Siren and Strobe or other programmable outputs. See section 4 and 8 (Programming Options). AC IN
3 Way 16Vac power input. Fused via F3 3A self-resetting fuse.
Batt
Leads 12V dc or battery connection via F1 (3 Amp self-resetting fuse. Low Voltage Terminals
NOTE: To reset the fuse, remove power for a few seconds and then reapply power.
7.1 Power Options The unit has 2 sources of power, 16VAC and 12VDC (Battery). NOTE: Use only rechargeable batteries. Always ensure adequate ventilation is available for the housing if it contains a battery. Lead acid batteries may emit explosive gases while charging! Always make sure that a battery is connected to the energizer before applying 16 VAC.
29
JVA ELECTRIC FENCE SYSTEMS 7.2 Status Codes
Technical Information
Status LED Number of Flashes
Interpretation
Corrective Action
1
Not used
2
16 VAC Mains fail
Restore mains power. Can be bypassed by fitting J3
3
Low battery, bad battery
Charge or replace battery
4
PCB service fault
Return to repair/service centre
Status Codes If an error occurs, the relay assigned to general alarm will go into alarm state. Minor errors will self clear if the error condition is removed. If the mains power fails, it will not disarm the energizer, nor will low battery. However, without mains power, the battery will eventually be depleted and the energizer will attempt to maintain operation by entering low power mode after 4 warning beeps. If the battery charge continues to fall, the energizer will eventually stop. Once mains power has been restored and the battery has recovered, the energizer will re-arm itself automatically after 4 warning beeps. A PCB fault will disarm the energizer. If an error disarms the energizer, the general and fence alarms will activate. If an error has momentarily caused the energizer to stop pulsing, this can be corrected by disarming and rearming the unit. Should the error recur, return the unit for service.
7.3 Jumpers The unit has two special purpose jumpers (links). These are listed in the table below. Jumper
Function
Purpose
J3
DC only jumper
Fit J3 to inhibit mains fail errors, if the intention is to operate the unit on DC only (as in Solar Power systems)
J4
Factory default jumper Off to return programmable options to factory defaults upon power up
If the energizer needs to be defaulted to factory settings, remove all power – AC and battery and remove the J4 jumper. Reapply the battery power first, then 16 VAC power. Reapply the J4 jumper and the unit will be reset to default settings.
Jumpers
7.4 Multiple Keypads All Z series energizers have support for up to three keypads provided the Energizers firmware version is 7v66 and above. If more than one keypad is desired one of the keypads must have an ID of 2, the other keypads can have an ID number from 1 to 8 but excluding ID 2. If only one keypad is desired any ID number from 1 to 8 can be used.
30
JVA ELECTRIC FENCE SYSTEMS
8. Group Mode (26x#) A group must have only 1 master. The other Energizers in the group are slaves. Since the keypad bus is common among the group, one keypad can be used to program all Energizers for all Options except Group Mode (for obvious reasons). If there is no Master, each Slave will electrify the fence (pulses) when Armed. However, the simultaneous pulse feature will NOT be operating. Connect the keypad to each Energizer in turn, before linking all Energizers into a group. Set this option, one unit as master the other as slaves.
Note 2: If more than one keypad is used, they will need different addresses.
Mode
0
No Group
1
Master
2
Slave 1
3
Slave 2
4
Slave 3
5
Slave 4
6
Slave 5
7
Slave 6
etc.
etc.
15
Slave 14
Group Mode (26x#)
Note 3: If Perimeter Patrol is used, any keypad in the system should not have address 2, (see page 18 Program this Keypad). For all Energizers that will be part of a group, the procedure is as follows: 1. Make sure the key switch is turned off and Input1 is not connected to the Com terminal. 2. Connect the battery. 3. Connect the keypad. 4. On the keypad, enter [Installer’s code] [*] [0] [#], then [26]. 5. Enter the required value (e.g. [1] for master) then [#]. 6. Enter [*] [#] to exit programming. 7. Connect the group using the keypad bus as per Figure 7.
Group Mode
Note 1: Do not interconnect the energizers via the keypad bus until after they are programmed.
Value
NOTE: At this time groups are limited to a master and 14 slaves (15 zones total). If more zones are required, PAE 212 LAN boards can be used. In Group Mode, only one keypad can be used. Note: In some markets Group Mode may not be available. For details on group wiring and operation Figure 7.
31
JVA ELECTRIC FENCE SYSTEMS Group linking via the Keypad “bus” The keypad terminals on all Energizers in the group are linked, see Figure 17. Since only one Energizer needs to power the keypad, 3 wires are linked from one Energizer (preferably the Master) to the keypad (optional) and 2 wires to every other Energizer in the group. Do not connect the + lines between Energizers as this could result in some strange behaviour and possibly damage. Note the connections can be a star or daisy chain or any mixture. It is possible for a PC to be added to the group using a keypad to RS232 adaptor (PAE051). We recommend following these steps in the right order: 1. Disarm all energizers in the group. If energizers are not disarmed Step 10 may not work correctly. 2. Program the keypad address using one of the energizers.
Group Mode
3. Program each energizer with its required address (Master address = 1, Slave 1 address = 2...). Refer to note 4 below. 4. Connect any control/monitoring unit 12V, GND and Data to the Group Master. 5. Connect all the slaves Data and GND to the Group Master. 6. Connect the battery and AC power of the Group Master but do not arm. 7. Connect the battery and AC power of each slave Note: Do not arm them until all the Energizers in the group are connected 8. Wait 5 minutes for all the Energizers to synchronise with the Master 9. If there are more than one keypad or control unit, make sure they have a different ID then reset the group using keypad code: [user pin] [*] [6] [8] [#] or Perimeter Patrol “Reset All” this will allow both keypads to be recognised by all energizers in the group. 10. If using a PTE0210 keypad (refer to Appendix I), enter the key sequence [*][6][8] [#] to automatically re-scan the group and check what energizers are connected. 11. Arm the group using keypad [1] [2] [3] [4] [*] [1] [0] [#] or Perimeter Patrol, make sure all Energizers are activated. Notes: 1. Members of a group can be individually switched on and off; even the master can be turned off via input or key switch (note that the Z14R does not have a key switch). 2. A slave will generate a General alarm if the keypad bus is broken between it and the group master. 3. After programming the Keypad may be disconnected, it is not required for group operation.
32
JVA ELECTRIC FENCE SYSTEMS 4. As of energizer firmware 7v83 and keypad firmware 1v09, Z28’s should have an ‘empty’ ID between each Energizer. This means if the Z28 master ID=1, then the ID of the first slave should be 3, not 2. 5. When connected to Perimeter Patrol, the arm/disarm function of a keypad is disabled. Control of these functions is through the Perimeter Patrol interface. 6. A Keypad that is connected to a Slave Energizer (that is disconnected from the Group) must have a KEYPAD ADDRESS set to 1 or 8. Otherwise the Energizer will not respond to commands. Z Series Energizer
Z Series Energizer
Z Series Energizer
LAN cable
PAE 212
Group Mode
Z Series Energizer
Group Installation notes
Figure 7: Group Mode Linking
1. If an Energizer hasn’t been programmed as a Master or a Slave, it is set as “Stand alone” by default. 2. All energizers need an appropriate high voltage circuit earth connection. 3. Allow for the heat load of multiple Energizers mounted inside a cabinet, approx. 10W each. 4. Use shielded or twisted pair cable for the group keypad wiring.
33
JVA ELECTRIC FENCE SYSTEMS
9. SECTOR SETUP TESTS AND ADJUSTMENT
Sector Setup Tests and Adjustment
With a single sector system there are three considerations for the electric fence monitor voltage level:
34
1. The monitor should trigger the alarm if one of the live wires is shorted to ground. 2. The monitor should trigger the alarm if one of the live wires is cut. Use common sense and turn the energizer off when making changes to the fence, then turn the energizer back on to check the effects.
9.1 Basic Fence Tests 1. Energise the newly-completed fence. 2. Use an Electric Fence Power Probe to find any construction faults. 3. Check that there is voltage on all live wires (continuity) and that there are no shorts from live to earth. 4. Check the electric fence earth. (See electric fence manuals.) One method is to make an intentional short from live wire to earthed metal. The voltage at the earthed point should be less than a few hundred volts; the voltage on the earth stake with respect to any nearby earthed metal should be less than a few hundred volts. 5. Record the start and end of fence live wire voltages. 6. Record the live wire currents going out from the energizer to the fence. At this point there must be a reasonable voltage on all parts of the fence. To be an effective barrier, the Power Probe (or voltmeter) readings between wires (live to earth) must be greater than 5.0kV. If they are not, a larger energizer may be required.
9.2 Fault Condition Tests 1. To simulate a break, disconnect a joint in the live wires at some convenient point on the fence, making sure that the wires do not short to ground or between +ve and -ve wires. 2. Check that the energizer fence alarm activates. If not, check the voltage (using an electric fence voltmeter) at the inputs to the monitor. Set the fence alarm voltage level higher than this voltage. If there is still considerable voltage, you may have induced voltage in the live return wires. If so, reduce the induced voltage by placing a 3000 Ohm, 10 Watt resistor between the live return and earth return terminals at the monitor. 3. Reconnect the live wires. 4. Place a short on the fence live wires. 5. Check that the monitor goes into alarm. 6. Remove the short. 7. Do Steps 4 –  6 for both zones.
JVA ELECTRIC FENCE SYSTEMS
10. Some Standard Requirements FOR ELECTRIC SECURITY FENCES The JVA range of energizers has been extensively tested and certified in accordance with international standards. JVA does not take responsibility for the erection standards of the fence. It is the responsibility of the erector to consult and comply with the Standards and Codes of Practice for the installation and erection of electric security fences. For the user’s convenience, we include some Standard Requirements here but the installer also needs to consult standards such as SABS 1063, 0142, SABS IEC 60335-2-76.
Physical Barrier A barrier of not less than 1.5m in height and intended to prevent inadvertent contact of persons with the conductors of the electric fence. NOTE: Physical barriers are typically constructed from vertical sheeting, rigid vertical bars, rigid mesh or rods of chain wire mesh. Public Access Area Any area where persons are protected from inadvertent contact with pulsed conductors by a physical barrier (see above). Pulsed Conductors Conductors that are subjected to high voltage pulses by the energizer. Secure Area An area where a person is not separated by a physical barrier (see above) from pulsed conductors (see above) below 1.5m.
Standard Requirements
10.1 Definitions
10.2 Installation, Operation and Maintenance 10.2.1 Electric security fences and their ancillary equipment shall be installed, operated and maintained in a way that minimises danger to persons, and reduces the risk of persons receiving an electric shock unless they attempt to penetrate the physical barrier, or are unauthorised to be in the secure area. 10.2.2 A space of 2.5m shall be maintained between uninsulated electric fence conductors or uninsulated connecting leads that are supplied from different energizers. This space can be less where the conductors or the connecting leads are covered by insulating sleeving, or consist of insulated cables that are rated to at least 10kV.
35
JVA ELECTRIC FENCE SYSTEMS 10.2.3 The requirement in 10.2.2 does not apply in cases where the separately energised conductors are separated by a physical barrier that has no openings greater than 50mm. 10.2.4 A vertical separation of not less than 2m shall be maintained between pulsed conductors fed from different energizers. 10.2.5 Mains supply wiring shall not be installed in the same conduit as signalling leads associated with the electric security fence installation, but shall be installed in accordance with the requirements given in SABS 0142. * NB. (Fence HT leads must under no circumstances be routed in the same conduit as any other wiring.)
Standard Requirements
10.3 Warning Signs NOTE: Regulation warning signs are available from all JVA Electric Fence centres and all JVA certified dealers. 10.3.1 Electric security fences shall be identified by prominently placed warning signs that shall be legible from the secure area and from the public area. 10.3.2 Each side of the electric security fence will have at least one warning sign. 10.3.3 A warning sign shall be placed: a. at each gate b. at each access point c. at intervals not exceeding 10m d. adjacent to each sign with regard to chemical hazards, for emergency services information.
10.4 Gates Gates in electric security fences shall be capable of being opened without the person who is operating the gate receiving a shock.
10.5 Earthing 10.5.1 Where an electric security fence passes below bare power line conductors, the highest metallic element shall be effectively earthed for a distance of not less than 5m on either side of the crossing point. 10.5.2 The distance between any electric fence earth electrode and other earth systems shall be not less than 10m, except when the earth system is associated with a graded earth mat. The earth electrode shall comply with SASS 10611. Amendment 1, Deco 2000 1. 10.5.3 All exposed conductive parts of the physical barrier shall be effectively earthed.
36
JVA ELECTRIC FENCE SYSTEMS 10.6 Protection 10.6.1 All ancillary equipment connected to the fence circuit shall be designed to provide a degree of isolation between a fence circuit and the supply mains equivalent to that specified for the energizer. 10.6.2 Protection from weather shall be provided for the ancillary equipment unless the equipment is certified by the manufacturer as being suitable for use outdoors, and is of a type with a minimum degree of protection IPX4 (protected against splashing water).
Power line voltage
Minimum clearance
<1 000
3m
>1 000 and <33 000
4m
>33 000
5m
Figure 1 Typical constructions where the electric security fence is exposed to the public.
Standard Requirements
Fence to Powerline Minimum Clearance
37
JVA ELECTRIC FENCE SYSTEMS Figure 2 Typical fence constructions where the electric security fence is installed in windows and skylights.
Standard Requirements
Key:
38
ď‚ Electric security fence ď‚‚
Physical barrier
Figure 3 Prohibited zone for pulsed conductors. Key: Electric security fence Physical barrier Prohibited zone
JVA ELECTRIC FENCE SYSTEMS
11. WARRANTY All JVA products carry a 2-year warranty against defective components and workmanship. The warranty excludes damage caused by acts of Nature such as lightning or flooding, power supply surges, rough handling, malicious actions or incorrect wiring. Whilst every effort has been made to check that the information contained is accurate, JVA Technologies Pty Ltd will not be liable to loss or damage resulting from construction, operation or failure of any installation or system. Installation of security electric fences should be made by trained professionals with regard to the relevant local standards and workplace health and safety requirements. Product model purchased: ...................................
Serial No: ............................
...................................................................................................
Address:
...................................................................................................
...................................................................................................
...................................................................................................
Postal Code:
........................................
Tel. No:
Cell: ................................. Landline: .....................................
email:
...................................................................................................
Date purchased:
.........................................
Invoice No:
.........................................
Dealer Name:
...................................................................................................
Warranty
Customer Name:
Dealer’s Stamp
 Mail to: SA JVA Service Department P.O. Box 13898, Cascades 3202
39
JVA ELECTRIC FENCE SYSTEMS
12. COMPLIANCE CERTIFICATE
CUSTOMISED CODES
INSTALLER DETAILS
Customer Pin No. .....................
Name ..........................................................
Installer Pin No: ........................
Phone No. .................................................. Date Of Installation ...................................
40
JVA ELECTRIC FENCE SYSTEMS
Z-RANGE Z14
RANGE FEATURES INCLUDE Z14 STANDARD AND BI-POLAR ENERGIZERS
Z18
Z18 STANDARD AND BI-POLAR ENERGIZERS
LCD voltage display Powerful 4 joules per zone peak output energy Designed to pass IEC60335.2.76 and EMC
GSM MONITORS AND CONTROLS JVA ENERGIZERS USING A CELL PHONE
9.2 9.0
standards (reports available on request) Wall mountable, robust enclosure with detachable PCB chassis for ease of installation and repair Earth monitor input Gate input Key-switch Keypad programmable Lower-power mode Entry/Exit delay from gate input trigger Switched +12V outputs for Siren and Strobe (up to 30 Watts for 3 minutes) Microprocessor controlled Outputs may be wired for BiPolar fences (excluding Z28) Multiple single-zone energizers can be wired as a group
WEB SERVER MONITORS AND CONTROLS ENERGIZERS VIA THE INTERNET
Z28
Z28 STANDARD ENERGIZER
Perimeter Patrol Complete control System monitoring Event logging
Customer Support For assistance: If you have any questions or need further assistance, please call your nearest JVA dealer. SA Tel. No.: 0861 782 349. For service or repairs: If a service or repair is required, please package and label your energizer carefully and return it to your local JVA Service Centre. For warranty repairs: Include proof of purchase, e.g. invoice. Note: Repair centre details are displayed on the back cover of this manual.
JVA ELECTRIC FENCE SYSTEMS JVA products are designed by JVA Technologies, Queensland, Australia and distributed to: AFRICA
AUSTRALIA
CENTRAL ASIA
CARIBBEAN
CENTRAL AMERICA
INDIA
LATINO AMERICA
EUROPE
NEW ZEALAND
MEXICO
RUSSIA
PHILIPPINES
Pakistan
SOUTH EAST ASIA
SRI LANKA
UNITED KINGDOM
USA
JVA RSA SERVICE CENTRES Bloemfontein 36 Kolbe Lane, Oranjesig Tel: 051 448 6695
Klerksdorp
Cape Town
Nelspruit
Unit 15, Viking Business Park Park Road (off Viking Way) Epping Industria Tel: 021 534 5056
Centurion
74 Cantonments Road, Lyttleton Tel: 012 880 0222
Durban North
Unit B, 13 Kenneth Kaunda Road (Old Northway) Tel: 031 563 0274
East London
Shop 8 & 9, Paphos Park Devereaux Avenue Tel: 043 726 6652/60
East Rand (Jet Park)
Aerostar Business Park 219 Jet Park Road, Jet Park Tel: 011 397 3507
George
Shop 3, 57 York Road, George Tel: 044 874 0669/ 044 873 2958
Kimberley
29 Schmidtsdrift Road Rhodesdene Tel: 053 861 5631
72 Central Avenue, Flamwood Tel: 018 468 8273 Unit 4, 20 Rapid Street Riverside Industrial Park Tel: 013 752 7152/55
North Rand (Kya Sand)
174 Bernie Street, Randburg Tel: 011 708 6442
Paarl
Shop 2, Huguenot Park, Cnr Klein Drakenstein Road and Van Der Merwe St., Paarl Tel 021 862 0886
Pietermaritzburg
51 Winston Road Tel: 033 342 6722/27
Pinetown
Pretoria
1185 Steve Biko Road, (977 Voortrekker Road), Wonderboom South Tel: 012 335 4290
Rustenburg
Shop 7, Waterfall Mall 1 Howick Avenue Tel: 014 537 2884
Somerset West
4 Broadway Centre Urtel Crescent Tel: 021 851 1978
Upington
Unit 2B, Industria Business Park 4 Progressus Street Tel: 054 332 1458
Vanderbijlpark
Unit 1, 7 Suffert Street Tel: 031 702 6351
5 Prime Business Park Rabie Street Tel: 016 931 0408
Polokwane
Vryheid
9 Suez Street, Nirvana Tel: 015 292 6273
Port Elizabeth
45 Mangold Street, Newton Park Tel: 041 365 7178/9
Potchefstroom
35 Dr James Moroko Street Tel: 018 297 1488
Unit F, 153 President Street Cnr. Hlobane Street Tel: 034 981 0318
West Rand (Roodepoort) 599 Ontdekkers Road Delaréy Roodepoort Tel: 011 472 8823
Nearest RSA branch: 0861 782349 • Website: www.jvasecurity.com • e-mail: support@jva-fence.com