Skip to main content

Spec Joist (SJI) - Site Cutting Guide - 200x45

Page 1

SERVICE HOLE LOCATION <TITLE GUIDE 1> SJI <TITLE 200x45 2>

SPECJO ST DO NOT CUT / DRILL HOLES IN THESE LOCATIONS

150mm

150mm

End Support

150mm

150mm

150mm

150mm

Intermediate Support

Exclusion Zone

Cantilever Support

x = Larger of Joist Height / 2 or 150mm

do not cut holes too close to supports

do not over cut holes

do not punch holes with hammer

do not cut or drill holes in flanges

ACCEPTABLE HOLE LOCATIONS 50mm or less holes in any location outside exclusion zones minimum of 300mm from supports 100mm from any other hole

100mm

A

h

B

h

B

Consider clusters of holes as a single larger hole

h

B

h

A

A = Distance from a support to a Hole B = Distance from a hole to another hole Distance

Minimum distance to the hole is the greater of

A

Length Shown on Table for the hole size required

B

Length Shown on Table for largest of the 2 adjacent holes

Joist Span (m)

75mm 115mm

Biggest Hole Width / Diameter x2

Notes: 1. Tables shown are for Residential Live Load (1.5 kPa) + 110kg/m2 Dead Load

Circular Holes Hole Diameter (mm)

or

3.0

3.6

4.2

4.8

2.

300 400

300 800

500 1100

900 1500

There is no maximum number of holes that can be cut into the joists provided they meet the above requirements

3.

Contact ITI for further design assistance is required

4.

Cut holes carefully. Do not over cut holes

5.

Do not cut the flanges of the I-Joists

6.

Holes may be located within the full depth of the web provided there is a minimum of a 5mm gap from the bottom of the hole to the flange

7.

No holes are to be cut into a cantilever

More Information: ITI Spec Joist (SJI) I-Joist Product Specification Guide

itiaustralia.com.au