Internal, Fully Protected
External, Above Ground, Unprotected
External, Above Ground, Fully Protected
External, Above Ground, Mostly Protected
Exposure Requirements
Internal, Fully Protected
External, Above Ground, Fully Protected
External, Above Ground, Mostly Protected
External, Above Ground, Unprotected
Additional Treatment required for Termites & Insects only
Additional Treatment required for Termites & Insects. If adequate ground clearance is not available products should be treated as if they are External, Above Ground, Mostly Protected.
H3 Treatment required in additional to being installed per the below guidelines
H3 Treatment required in additional to being installed per the below guidelines
INSTALLATION REQUIEMENTS OF H3 TREATED LVL PRODUCTS:
H3 VENEER TREATED LVL
February 2026
Laminated Veneer Lumber (LVL) products must only be used in exposed applications where wetting is periodic and can dry efficiently.
Metsa Kerto LVL and ITI Spec Frame LVL must not be used in exposed structural applications where the installed LVL can not be regularly inspected for signs of moisture damage.
Care is to be taken to avoid situations where water can pool or become trapped between the LVL and its supports or joints.
Coating System Recommendation
Clear penetrating water repellent oils and sealants
Semi-transparent to full colour penetrating exterior timber stains
Solid colour exterior acrylic paints
Apply as per manufacturer’s directions. May require frequent re-application (6–12 months).
Apply 2 to 3 coats as per manufacturer’s directions.
Apply a good quality, long oil based exterior wood primer followed by two coats of premium quality exterior acrylic paint according to the manufacturer’s recommendations.
Solid colour exterior gloss enamel Not recommended. Clear or semitransparent exterior gloss or varnish Not recommended.
1. The builder / end user is to retain the Treatment End Tags as evidence of treatment type and provider.
2. All edges and faces of members are to be painted / sealed prior to installation using an acceptable coating method, such as an acrylic system, using the manufacturers installation requirements.
3. Always install a protective barrier to the top edge and exposed ends of all LVL’s in exposed applications using either tesa JoistSeal, a malthoid type barrier flashing or similar.
4. Treatment chemical providers stipulate the LVL should be left for a minimum of 7 days after treating and wiped clean of dust, dirt, grease and any other residues before painting.
5. Coating systems are to be regularly maintained in accordance with the manufacture’s requirements.
6. Refer to AS1684.2 Appendix B for additional information on Timber Durability.
7. ITI offer alternative products which are specifically developed for use in high moisture and exposed applications. Please discuss alternative options with your timber supplier if you feel the above requirements are not practical for your intended application.
Failure to install H3 Treated Spec FRAME OR SPEC BEAM LVL in accordance with the recommendations above will result in a retraction of liability by ITI towardS the product and associated treatments
tesa JoistSeal, or similar, wrapped over the top and exposed ends of the joists
tesa JoistSeal, or similar, wrapped over the top and exposed ends of the Bearer
Timber Decking
Bearer
Joists