The economic growth and rapid urbanization in hilly region has accelerated the real estate development therefore,
population density in the hilly areas has increased. In some hilly areas seismic activity is more serve so buildings in sloping
ground should be earthquake resistant to overcome the lateral forces. In the present study, comparative study of buildings
resting on sloping ground and plane ground is carried out by using ETABS 2016 under equivalent static analysis and response
spectrum analysis. Also comparison of codes is done (IS Code 1983:2002 vs IS Code 1983:2016) by considering displacement,
story drift and base shear as outcomes. Sloping angles (0, 10, 20) are taken for G+10 buildings for modelling and analysed. After
the analysis is done, a result obtained shows that displacement and story drift has increased in models analysed by IS Code
1983:2016 when compared with Is Code 1983:2002. Also base shear is reduced in models analysed by IS Code 1983:2016 when
compared with IS Code 1983:2002.