B Futura Upgrading the best
STERILIZATION FIRST
MBFGB191S00 02/2019
Supreme
Tethys T60 - Tethys D60
Tethys T45
Millseal+Evo
Millseal Rolling
Highea 6
Highea 9
STERILIZERS
Tethys H10 plus
THERMAL-DISINFECTION
Millseal+Manual
THERMAL SEALERS
Highea 3
WASHING
easy, it’s Mocom
Cefla s.c. reserves the right to modify the products illustrated in the photos without prior notice.
B Futura
According to the regulations in force, some products and/or features may have different availability and characteristics in areas outside of the European Union. Please contact your local distributor.
B Classic
B Futura Upgrading the best
Our vision. For over thirty years, safety, reliability and innovation have been the guiding principles behind all aspects of design and production at Mocom, the world’s leading sterilization firm. The factors that set us apart, in terms of both skill and innovation, are conscientious attention to the choice of materials, ground-breaking technology, enforcement of strict production/quality control protocols and the wealth of experience accumulated by our qualified, specialised sterilization system designers. Mocom, sterilization first.
STERILIZATION FIRST
Sede Legale ed Amministrativa Headquarters CEFLA s.c. Via Selice Provinciale, 23/a 40026 Imola (BO) - Italy Tel. +39 0542 653111 Fax +39 0542 653344
Stabilimento / Plant Via Bicocca, 14/C 40026 Imola (BO) - Italy Tel. +39 0542 653441 Fax +39 0542 653601 www.mocom.com infomocom@mocom.it
STERILIZATION FIRST
B Futura
The first one capable of using tap water Incorporated filtration in a stand-alone machine The incorporated system makes it possible to increase the surgery efficiency, eliminating demineralised water management issues. Recipients’ storage and deterioration of machine internal components caused by poor water quality will be a thing of the past.
Operating principle Unlike traditional sterilizers, Futura does not require any external water connection for mains water treatment. Thanks to the demineralisation filter on the main tank, the user can fill the latter with plain tap water, thereby significantly optimising spaces, streamlining processes and achieving considerable savings. Futura’s filtration system guarantees unprecedented ease of operation.
Efficiency and saving Never before has a sterilizer provided such high performance and low usage costs. Since water is demineralised by Futura’s filter, the user does not need to source demineralised water: they will only have to fill up the machine tank with tap water.
4
5
B Futura
Advanced connectivity Incorporated WiFi for remote support and optional cloud At the end of each sterilization cycle, the machine stores a report inside its memory. The user can download the cycles in PDF format at any time through the front USB port or automatically store them in the cloud using the WiFi and Di.V.A. system.
Di.V.A. Di.V.A. stands for Digital Virtual Assistant. It is the first cloud-based control and traceability system for MOCOM sterilization devices. Once saved, data will be available for operators by accessing a dedicated web page. Di.V.A. allows you to: - Get access to tutorial videos - Display the executed cycles - Check machine efficiency and status - Read the machine usage statistics - Monitor the frequency of sterilization tests
Remote technical support with Easy Check All sterilizers of the Futura range are equipped with incorporated WiFi and Ethernet port. Connected to the Internet by enabling the Easy Check service, they can receive remote support. Intervention times can be significantly reduced thereby allowing technicians to keep machines constantly efficient.
Printer The Futura range can be completed with an external printer available as an optional accessory, able to provide reports or bar code labels.
Traceability software MyTrace is Cefla’s traceability software available for Futura. By using this programme, each set of sterilized instruments can be associated to the patient through a bar code. This essential software completes the sterilization process and provides legal protection to dentists.
6
7
B Futura
Ease of use 4.3� colour touch-screen for a user-friendly interface The B Futura sterilizer is a smart and essential working tool that ensures excellent performance also thanks to the colour LCD touch screen and user-friendly interface. Each control corresponds to icons that ensure an immediate reading of the machine status.
Delayed start Thanks to the delayed start option it is possible to postpone the start of the machine cycles, thereby optimising its usage.
Extra drying This function is used to set customised drying times for demanding loads.
Custom cycle Cycle parameters can be set to meet specific user needs (in complete safety) by choosing from among a wide range of standard-compliant values.
User ID Authorises personnel in charge to get access to the sterilizer. By entering a security code (PIN number), operators can keep track of the usage history of the machine while ensuring process control.
Test reminder By setting this function on the display, Futura will inform the user when a Vacuum Test, Helix Test or Bowie & Dick test must be carried out. Therefore, it will become impossible to forget about these important operations.
8
9
B Futura
Accessories A full range of accessories to expand Futura’s functions.
1
External printer Connected to the Futura sterilizers via an RS232 serial port, it allows executed cycle data to be printed on rolls of thermal paper or bar code labels.
2
Front filling kit Allows the operator to fill the main tank frontally through a quick coupling..
3
Automatic filling kit Consists of an external pump powered by the sterilizer and allows demineralised water to be withdrawn from a tank or recipient.
4
5
Rated power
This kit allows the sterilizer to be interfaced with the surgery water supply system so the sterilizer only draws water from the system as and when necessary.
External dimensions WxHxD
Modular tray holder
Chamber dimensions Diam. x Depth
B Futura 22
B Futura 28
220/240V 50Hz 220/230V 60Hz 2300 W 480 x 500 x 600 mm 250 x 350 mm
250 x 450 mm
280 x 450 mm
51 kg
52 kg
53 kg
Total weight Tank capacity Autonomy (with max. water level)
Bar code reader
B Futura 17
Power supply voltage
SV aux kit
Modular housing system for filling the sterilizer. Provided with 3 pairs of tray-housing shelves, it allows for the full use of the chamber diameter and the introduction of even cumbersome loads. 6
Technical data
4.5 litres From 7 to 11 cycles
From 6 to 10 cycles
From 5 to 9 cycles
The bar code reader, usable on the most common PCs, makes it possible to complete the traceability process and associate bar code labels to patients. Sterilization cycles 220/230 V CYCLE
Cycle type
Sterilization time (min.)
1
2
3
B Futura 17
B Futura 22
B Futura 28
Drying *
Cycle times including sterilization times, net of drying times (min.)
134 °C UNIVERSAL
B
4
27
29
37
13-17
121 °C UNIVERSAL
B
20
43
46
50
13-17
134 °C UNWRAPPED HOLLOW INSTRUMENTS
S
4
29
32
36
4-6
134 °C WRAPPED SOLID INSTRUMENTS
S
4
18
22
26
13-17
134 °C PRION
B
18
41
43
51
13-17
XXX °C CUSTOM
S
Cycle can be personalised by user at temperatures 134 °C / 121 °C, process times starting from 4’ (134 °C) or 20’ (121 °C) with adjustable drying
VACUUM TEST
TEST
18
18
19
HELIX / B&D TEST
TEST
20
24
28
TEST
42
46
51
VACUUM + HELIX / B&D TEST (executed in sequence) 4
5
6 * Drying varies according to machine model and volume Note: times do not take the max. pre-heating time into account (10 min.).
10
Note: times may vary depending on the load and power supply. Note: 120 V model times may undergo increments up to a max. of 20%. 11
MBFGB191S00 02/2019
Tethys H10 plus
Tethys T60 - Tethys D60
Tethys T45
Millseal+Manual
Millseal+Evo
Millseal Rolling
Highea 6
Highea 9
THERMAL SEALERS
Highea 3
WASHING
easy, it’s Mocom Our vision. For over thirty years, safety, reliability and innovation have been the guiding principles behind all aspects of design and production at Mocom, the world’s leading sterilization firm. The factors that set us apart, in terms of both skill and innovation, are conscientious attention to the choice of materials, ground-breaking technology, enforcement of strict production/quality control protocols and the wealth of experience accumulated by our qualified, specialised sterilization system designers. Mocom, sterilization first.
STERILIZATION FIRST
Sede Legale ed Amministrativa Headquarters CEFLA s.c. Via Selice Provinciale, 23/a 40026 Imola (BO) - Italy Tel. +39 0542 653111 Fax +39 0542 653344
Stabilimento / Plant Via Bicocca, 14/C 40026 Imola (BO) - Italy Tel. +39 0542 653441 Fax +39 0542 653601 www.mocom.com infomocom@mocom.it
Cefla s.c. reserves the right to modify the products illustrated in the photos without prior notice.
Supreme
STERILIZERS
According to the regulations in force, some products and/or features may have different availability and characteristics in areas outside of the European Union. Please contact your local distributor.
B Futura
B Classic