320C EXCAVATOR SBN SBN00001-UP
Note: Use Bookmarks panel to navigate Printed by Heavy Equipment Manuals v2.20
Printed in U.S.A
Heavy Equipment Manuals
This is the sample of the manual click on the download link for complete manual
DOWNLOAD LINK For some reason if link does not work download this pdf and then click
Product: EXCAVATOR Model: 320C EXCAVATOR SBN Configuration: 320C & 320C L Excavators SBN00001-UP (MACHINE) POWERED BY 3066 Engine
Disassembly and Assembly 320C Excavator Machine Systems Media Number -RENR3826-16
Publication Date -01/11/2014
Date Updated -30/03/2016
i01969265
Accumulator (Hydraulic Pilot) - Remove and Install SMCS - 5077-011-PS; 5077-012-PS
Removal Procedure Start By: a. Release the hydraulic system pressure. Refer to Disassembly and Assembly, "Hydraulic System Pressure - Release". Note: The hydraulic accumulator is installed under the main control valve.
NOTICE Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat® products. Dispose of all fluids according to local regulations and mandates.
At operating temperature, the hydraulic oil is hot and under pressure. Hot oils can cause burns.
To prevent possible personal injury, release the pressure in the work tool hydraulic circuit (boom, stick, bucket, and swing), travel circuits, and the hydraulic oil tank at the filler cap before any hydraulic lines or components are disconnected or removed. Remove the filler cap only when the engine is stopped and the filler cap is cool enough to touch.
Note: A hydraulic oil sample should be obtained before any maintenance is performed in order to establish the system contaminant level. Refer to Fluid Analysis Laboratory Guide, SEBF3116, "Obtaining an Oil Sample for S·O·S Analysis". Refer to Operation and Maintenance Manual, "Sampling Interval and Location of Sampling Valve" for the correct location.
Illustration 1
g00715909
1. Remove bolts (2). 2. Remove sheet (1). Sheet (1) weighs approximately 6 kg (13 lb).
Illustration 2
g00715910
Note: Do not release the nitrogen from the hydraulic accumulator unless the unit will be disassembled.
3. Remove hydraulic accumulator (3) by turning the nut that is located at the top of the accumulator. Remove the O-ring seal from the accumulator.
Installation Procedure Table 1 Required Tools Tool
Part Number
Part Description
Qty
A
1U-6396
O-Ring Assembly Compound
7S-5437
Nitrogen Charging Group
1
7S-5439
Extension Assembly
1
B
Note: O-ring seals, gaskets, and seals should always be replaced. A used O-ring seal may not have the same sealing properties as a new O-ring seal. Use Tooling (A) during the assembly procedure. 1. Replace the O-ring seal with a new O-ring seal. Install the O-ring seal in the accumulator.
Illustration 3
g00715910
2. Install hydraulic accumulator (3) by tightening the nut that is located at the top of the accumulator.
Illustration 4
g00715909
3. Install sheet (1). Install bolts (2). 4. If the hydraulic accumulator was disassembled, use Tooling (B) to recharge the hydraulic accumulator. 5. Check the oil level in the hydraulic oil tank. Fill the hydraulic oil tank with oil to the correct level. Refer to the Operation and Maintenance Manual, "Lubricant Viscosities" for the proper oil viscosity. Refer to the Operation and Maintenance Manual, "Hydraulic System Oil Level - Check" for the correct filling procedure. 6. Install high efficiency filters in place of the pilot filter, the case drain filter, and the return filter. Note: High efficiency filters should not be run for more than 250 hours before you change back to the standard filters. 7. Obtain a hydraulic oil sample from the main S·O·S port. Reference: Refer to Operation and Maintenance Manual, "Sampling Interval and Location of Sampling Valve" for the correct location. 8. If the S·O·S sample exceeds ISO 18/15, flush the hydraulic system. Reference: Refer to Contamination Control Guidelines, SEBF8436, "Hydraulic System Flushing Procedure for 320C Hydraulic Excavators" for further information. Copyright 1993 - 2024 Caterpillar Inc. All Rights Reserved. Private Network For SIS Licensees.
Wed Nov 13 16:04:26 UTC+0530 2024
Product: EXCAVATOR Model: 320C EXCAVATOR SBN Configuration: 320C & 320C L Excavators SBN00001-UP (MACHINE) POWERED BY 3066 Engine
Disassembly and Assembly 320C Excavator Machine Systems Media Number -RENR3826-16
Publication Date -01/11/2014
Date Updated -30/03/2016
i02333043
Actuator Motor (Air Distributor) - Remove and Install SMCS - 7304-010-MQ; 7309-010-MQ; 7320-010-MQ
Removal Procedure Start By: a. Remove the storage box in the cab. Refer to Disassembly and Assembly, "Storage Box and Covers (Cab) - Remove and Install".
Removal Procedure of the Actuator Motor for the Air Damper for the Temperature Control
Illustration 1
g00699772
1. Disconnect harness assembly (1) from the actuator motor.
Illustration 2
g00699776
2. Remove screw (2) in order to disconnect linkage (3).
Illustration 3
g00699782
3. Remove screws (4) from the actuator motor. 4. Remove actuator motor (5).
Illustration 4
g00699790
5. Remove linkage (6) from the actuator motor.
Removal Procedure of the Actuator Motor for the Front Air Damper
Illustration 5
g00699809
1. Disconnect harness assembly (1) from the actuator motor.
Illustration 6
g00699811
2. Remove screw (4). Remove the cable strap for the harness assembly. 3. Remove screws (2) from the actuator motor. 4. Remove actuator motor (5).
Illustration 7
g00699816
5. Remove linkage (3) from the actuator motor.
Removal Procedure of the Actuator Motor for the Fresh Air or Recirculated Air Damper
Illustration 8
g00699825
1. Disconnect harness assembly (1) from the actuator motor.
Illustration 9
2. Remove screw (2) from the linkage.
g00699828
Illustration 10
g00699833
The heating and air conditioning unit is removed for photographic purposes.
3. Remove screws (3) from the actuator motor. 4. Remove actuator motor (4).
Illustration 11
g00699850
5. Remove linkage (5) from the actuator motor.
Removal Procedure of the Actuator Motor for the Air Damper for the Rear Window Defroster
Illustration 12
g00699868
1. Remove air duct (1).
Illustration 13
g00700177
Illustration 14
g00699876
The heating and air conditioning unit is removed for photographic purposes.
2. Disconnect harness assembly (2) from the actuator motor. 3. Remove cam (3) from the actuator motor.
Illustration 15
g00700179
Illustration 16
g00699881
The heating and air conditioning unit is removed for photographic purposes.
4. Remove screws (4). 5. Remove actuator motor (5).
Removal Procedure of the Actuator Motor for the Air Damper for the Front Window
Illustration 17
g00699893
1. Disconnect harness assembly (1) from the actuator motor.
Illustration 18
g00699902
2. Remove screws (2). 3. Remove actuator motor (3).
Illustration 19
g00699909
4. Remove linkage (4) from the actuator motor.
Installation Procedure Installation Procedure of the Actuator Motor for the Air Damper for the Temperature Control
Illustration 20
g00699790
1. Install linkage (6) on the actuator motor.
Illustration 21
g00699782
2. Install actuator motor (5) on the heating and air conditioning unit. 3. Install screws (4) in the actuator motor.
Illustration 22
g00699776
Note: Make sure that the linkage is properly aligned in the air actuator. 4. Connect linkage (3). Install screw (2).
Illustration 23
g00699772
5. Connect harness assembly (1) to the actuator motor.
Installation Procedure of the Actuator Motor for the Front Air Damper
Illustration 24
g00699816
1. Install linkage (3) on the actuator motor.
Illustration 25
g00699811
Note: Make sure that linkage (3) is properly aligned with the air actuator. 2. Install actuator motor (5). 3. Install screws (2) in the actuator motor. 4. Install a new cable strap for the harness assembly. Install screw (4).
Illustration 26
g00699809
5. Connect harness assembly (1) to the actuator motor.
Installation Procedure of the Actuator Motor for the Fresh Air or Recirculated Air Damper
Illustration 27
1. Install linkage (5) on the actuator motor.
g00699850
Illustration 28
g00699833
The heating and air conditioning unit is removed for photographic purposes.
2. Install actuator motor (4). 3. Install screws (3) in the actuator motor.
Illustration 29
g00699828
4. Connect the linkage to the air actuator. 5. Install screw (2) in the linkage.
Illustration 30
g00699825
6. Connect harness assembly (1) to the actuator motor.
Installation Procedure of the Actuator Motor for the Air Damper for the Rear Window Defroster
Illustration 31
g00699881
The heating and air conditioning unit is removed for photographic purposes.
1. Install actuator motor (5). 2. Install screws (4).
Illustration 32
g00699876
The heating and air conditioning unit is removed for photographic purposes.
Note: Make sure that the linkages for the air dampers are installed in the cam. 3. Install cam (3) on the actuator motor. 4. Connect harness assembly (2) to the actuator motor.
Illustration 33
g00699868
5. Install air duct (1).
Installation Procedure of the Actuator Motor for the Air Damper for the Front Window
Illustration 34
g00699909
1. Install linkage (4) on the actuator motor.
Illustration 35
g00699902
2. Install actuator motor (3). 3. Install screws (2).
Illustration 36
g00699893
4. Connect harness assembly (1) to the actuator motor. End By: a. Install the storage box in the cab. Refer to Disassembly and Assembly, "Storage Box and Covers (Cab) - Remove and Install". Copyright 1993 - 2024 Caterpillar Inc. All Rights Reserved. Private Network For SIS Licensees.
Wed Nov 13 15:32:22 UTC+0530 2024
Product: EXCAVATOR Model: 320C EXCAVATOR SBN Configuration: 320C & 320C L Excavators SBN00001-UP (MACHINE) POWERED BY 3066 Engine
Disassembly and Assembly 320C Excavator Machine Systems Media Number -RENR3826-16
Publication Date -01/11/2014
Date Updated -30/03/2016
i02426971
Auxiliary Pilot Valve (Straight Travel) - Assemble SMCS - 5059-016-AX
Assembly Procedure Table 1 Required Tools Tool
Part Number
Part Description
Qty
(A)
1U-6396
O-Ring Assembly Compound
1
Note: Cleanliness is an important factor. Before assembly, all parts should be thoroughly cleaned in cleaning fluid. Allow the parts to air dry. Wiping cloths or rags should not be used to dry parts. Lint may be deposited on the parts which may cause later trouble. Inspect all parts. If any parts are worn or damaged, use new parts for replacement. All disassembly and all assembly procedures must be performed on a clean work surface and in a clean hydraulic area. Keep cleaned parts covered and protected at all times. Note: O-rings, gaskets, and seals should always be replaced. A used O-ring may not have the same sealing properties as a new O-ring. Use Tooling (A) during the assembly procedure.
This is the sample of the manual click on the download link for complete manual
DOWNLOAD LINK For some reason if link does not work download this pdf and then click