1/2” GEN2 Check Valve | Technical Marketing Sheet

Dependable check valve performance you can count on to prevent unwanted backflow within your control systems. Gilmore developed the 1/2” GEN2 Check Valve product line to improve field performance in backflow prevention. Customer feedback was essential to the redesign of a more reliable and field serviceable valve.

FUNCTIONAL DESIGN SPECIFICATIONS Maximum Allowable Working Pressure

5000 PSI

Standard Cracking Pressure

60 PSI ±15 PSI

Recommended Maximum Operating Flow

25 GPM

Flow Coefficent (Cv-Calculated)

1.0

Qualified Life Cycle

2500 Cycles

Operating Temperature Range

32˚F to 150˚F

Acceptable Operating Fluid Types

Water or mineral oil-based drilling control fluid

Two separate endurance tests at 2500 cycles each

Mounting Restrictions

None

US Patent

10,385,982

Hyperbaric Chamber test to 100 cycles at 15,000 ft. depth

Maximum Operating Depth

15,000 ft

Figure 1. PN 29001-1: GEN2 Check valve, Pilot Operated

Features and benefits • Qualification exceeds API 16D requirements

• Redesigned legacy ball type check to a more reliable guided poppet check mechanism • Enhanced material selection across entire valve • Shouldered poppet design to prevent reverse flow failure • Field serviceable • Improved valve materials: 316SS body Nitronic 60 Poppet Check Mechanism Delrin 511P seal seat HNBR O-rings w/PEEK double backup rings Nitronic 60 piston plunger Elgiloy Springs

INFO@Gilmore.com www.gilmore.com GEN2 Check Valve and POVC Half Inch 4-15-2026 Rev.

Figure 2: PN 29001-1

Figure 3: PN 29114

Figure 2: PN 29001-1, GEN2 Check Valve, 1/2” Pilot Operated Figure 3: PN 29114, GEN2 Check Valve, 1/2” NPT Throttling Pilot Operated to handle 5000 psi full differential pressure while ensuring valves integrity.


Turn static files into dynamic content formats.

Create a flipbook
Gilmore GEN2 Check Valve -Half Inch Product Sheet by Gilmore - Issuu