Bezdan Cable Fascia Mount Installation Guide, Stairs and Level- USA

Page 1

n Bezdan Cable | CR1650/CR1651/CR1750/CR1751 Stair, Fascia Mount Post

Installation Instructions for Posts Stair, Fascia Mount Level, End Post

Min. 42"

4"

First Stair Post

48" max. spacing on center between posts 2"

Floor Substrate

Min. 1-1/2" thick handrail

40" max. spacing on center between posts 2" 2"

Fascia Surface 2"

2"

Note: If installing both stair and level runs, stair fascia mount posts must be installed before level fascia mount posts.

40" max. spacing on center between posts 2"

2" Min. 36" 2"

A. Fascia Surface Construction Requirements

2"

WOOD SURFACE

CONCRETE SURFACE

STEEL SURFACE

4 Lumber grade must be a minimum of SPF Sawn Lumber No.2 or better

4 Minimum 20 MPa compressive strength or better

4 Minimum 300W grade or better

4 Lumber must be a minimum of 3" thick

4 Minimum 3/8" thick

4 Concrete must be minimum 5" thick

4 Each 2x10 beam shall be affixed to the top plywood floor with fasteners at every 6" 4 Wood must be dry and seasoned prior to installation and fabrication 4 Wood should not be treated with fire retardants or other strength reducing chemicals

FOR ALL TYPES OF FASCIA SURFACES, MINIMUM EDGE DISTANCES MUST BE MAINTAINED POST SPACING u First Stair Post: Maintain a maximum 4" space between Level, End Post and the First Stair Post (refer to diagram above). u Stair Posts: Ensure 40" maximum spacing on center between posts on stairs (refer to diagram above).

05/23

geobezdan.com

1 800 663 6356

MINIMUM EDGE DISTANCE u Vertical: There must be at least 2" from the top edge of the fascia surface to the center of the first predrilled anchor hole of the post. u Horizontal: There must be at least 2" from the edge of the fascia surface to the centerline of the post.