M-Series and P-Series Catalog Spring 2020
EZ FIT™
kumo touch™
Designer Series Wall Mount
2
Doing Our Part to Create a Better Future for All...
Core Environmental Policy The Mitsubishi Electric Group promotes sustainable development and is committed to protecting and restoring the global environment through technology, all business activities and the actions of our employees.
Environmental Vision 2021 Making Positive Contributions to the Earth and its People through Technology and Action
Preventing Global Warming
Creating a Recycling-Based Society
● lReduce CO2 emissions from product usage by 30% ● lReduce total CO2 emissions from production by 30% ● lAim to reduce CO2 emissions from power generation
● Reduce, reuse and recycle “3Rs” products shrink resources used by 30% ● Zero emissions from manufacturing reducing the direct landfill of waste to zero
Ensuring Harmony with Nature Fostering Environmental Awareness
Mitsubishi Electric reflects the essence of this policy and vision in all aspects of its air conditioner business. Preventing Global Warming
Heat pump technology inspires Mitsubishi Electric to design air conditioners that combine comfort and ecology.
Mitsubishi Electric develops technologies to balance comfort and ecology, achieving greater efficiency in heat pump operation. Comfort
Heat Pump Principle (When Heating) <Case of COP of 5.0> Refrigerant and Heat Circulation
3,600 BTU/H Electrical Energy Input
1. Inverter
Faster start-up and more stable indoor temperature than non-inverter units.
Fewer On/Off operations than with non-inverter saving energy.
2. 3D i-see Sensor®
Since the position of people can be detected, airflow can be set to personal selection, such as direct airflow path. The ability to adjust to individual preferences results in more comfortable air conditioning.
Since the number of people in a room can be detected, energy-saving operation is adjusted or the power is turned off automatically. Efficient air conditioning with less waste is realized.
3. Flash Injection
Achieves high heating capacity even at low temperatures plus faster start-up compared to conventional inverters.
Expands the geographical region covered by heat pump heating systems.
Compressor compresses the refrigerant which raises the temperature
176° F 68° F Compressor
Indoors
Outdoors
14,400 BTU/H Heat absorbed from the air
86° F
18,000 BTU/H Condenser
Evaporator
Heat output
Expansion valve
41° F
Expansion valve expands refrigerant to lower the temperature
122° F
Heat
Ecology
3
4
CONTENTS Product Line-Up Quality and Testing Inverter Technologies
6-11
12-13
14-15
Features
16-29
M-Series
30-69
P-Series
70-107
M-Series Multi-zone Outdoor Units Conditions for Specifications Piping Installation
108-115 116 117-120
Explanation of Terminology
121
Installation In Cold Regions
122-123
System Control
124-127
Optional Parts
128-147
Additional Information
148-155
Correction Factors
156-159
External Dimensions
160-171
5
M-Series Model Reference Guide M X Z - 2 C 20 N A HZ 2-U* Family
M = Mini-Split S = Mini-Split
Type
S = Wall-mounted indoor unit E = Horizontal-ducted indoor unit F = Floor-mounted unit L = Ceiling cassette indoor unit V = Multi-position AHU U = Single-zone outdoor unit X = Multi-zone outdoor unit
Service Reference Number Model Version Hyper-Heating Designation
Z = H2i® Hyper-Heating
Base Pan Heater Designation
H = Base Pan Heater
Control Method A = Control
Cooling Only / Heat Pump
Y = Cooling Only (INVERTER-Driven) Z = Heat Pump (INVERTER-Driven)
Number of Zones Multi-zone Only
W = 115V N = 208/230V
Capacity (Nominal) BTU/H (X 1,000)
System Generation
•
Designed for residential applications
•
Hyper-Heating INVERTER® (H2i®) outdoor units can provide high heating performance at lower ambient temperatures
•
•
6
System Voltage
User-friendly zoned cooling and heating solutions for single- or multi-room applications or the whole home
Many ENERGY STAR® certified models
P-Series Model Reference Guide
P UZ
A 2 4 NHA 7-B S
Family
P = Professional
Type
K = Wall-mounted indoor unit C = Ceiling-suspended indoor unit L = Ceiling cassette indoor unit E = Horizontal-ducted indoor unit V = Multi-position AHU U = Single-zone outdoor unit
BS = S eacoast Protection Model Version
Control Method A = A-control Generation H = Model generation
Cooling Only / Heat Pump
Y = Cooling Only (INVERTER-driven) Z = Heat Pump (INVERTER-driven) A = Both Heating And Cooling
Generation
A = Standard heat pump HA = Hyper-Heating INVERTER Unit
• • •
•
•
Compressor Voltage N = 208/230V
Capacity (Nominal) BTU/H (X 1,000)
Designed for light commercial installations. Ideal for applications requiring year-round, low ambient cooling such as computer, elevator and equipment rooms
Hyper-Heating INVERTER® (H2i®) outdoor units can provide superior heating performance at lower ambient temperatures Long lineset lengths
Outside air intake on PLA, PCA, PEAD and PVA models
P-Series ducted units have higher static than most M-Series, allowing for design flexibility
7
M-Series Model Name MSZ-FH Model
6,000 BTU/H
9,000 BTU/H
12,000 BTU/H
15,000 BTU/H
18,000 BTU/H
•
•
•
•
•
MSZ-EF Model
•
Wall Mounted
MSZ-GL/D Model
•
MSZ-HM Model
JP Model
Floor Mounted EZ FIT™ Ceiling Cassette Multi-position Air Handler Ceiling Cassette Horizontal Ducted
8
MFZ Model
MLZ Model
SEZ Model
*1 MXZ connection only *2 Single-zone connection only
•
•
•
•
•
•
•
•
W·S·B *1
W·S·B *1
•
•
•
•
•
•
•
•
•
•
•
*2
*2
*2
*2
• • •
*2
*2
*2
*2
*2
•
*2
*2
•
*2
•
•
*2
*2
•
•
•
•
•
•
•
SVZ Model
SLZ Model
36,000 BTU/H
W·S·B *1
• COOLING ONLY
•
30,000 BTU/H
W·S·B *1
•
WR Model
MSY-GL/D Model
*1
•
24,000 BTU/H
•
*2
*2
*2
•
•
•
•
•
•
•
•
•
•
*2
W•S•B: Indoor units are available in three colors; White, Silver, and Black.
MXZ Model Model Name MXZ-2C20NA2 up to 2 indoor units
MXZ-3C24NA2 up to 3 indoor units
Heat Pump
MXZ-3C30NA2 up to 3 indoor units
MXZ-4C36NA2 up to 4 indoor units
MXZ-5C42NA2 up to 5 indoor units
MXZ-8C48NA2 *3 up to 8 indoor units
MXZ-8C60NA2 *3 up to 8 indoor units
MXZ-2C20NAHZ2 up to 2 indoor units
MXZ-3C24NAHZ2 up to 3 indoor units
Hyper Heat
MXZ-3C30NAHZ2 up to 3 indoor units
MXZ-4C36NAHZ2 *3 up to 4 indoor units
MXZ-5C42NAHZ2 *3 up to 5 indoor units
MXZ-8C48NAHZ2 *3 up to 8 indoor units
Capacity
Wall Mounted
Floor Mounted
EZ FITâ„¢ Ceiling Cassette
4-way Ceiling Cassette
Horizontal Ducted
20,000 BTU/H [1-phase]
MSZ-FH06/09/12/15 MSZ-EF09/12/15 MSZ-GL06/09/12/15
MFZ-KJ 09/12/15
MLZ-KP 09/12
SLZ-KF09/12
SEZ-KD09/12/15 PEAD-A12
SVZ-KP12
24,000 BTU/H [1-phase]
MSZFH06/09/12/15/18 MSZ-EF09/12/15/18 MSZGL06/09/12/15/18
MFZ-KJ 09/12/ 15/18
MLZ-KP0 9/12/18
SLZ-KF09/12/15 PLA-A18
SEZ-KD09/12/15/18 PEAD-A12/18
SVZ-KP12/18
30,000 BTU/H [1-phase]
MSZFH06/09/12/15/18 MSZ-EF09/12/15/18 MSZGL06/09/12/15/18/24
MFZ-KJ 09/12/ 15/18
MLZ-KP 09/12/18
SLZ-KF09/12/15 PLA-A18
SEZ-KD09/12/15/18 PEAD-A12/18/24
SVZ-KP12/ 18/24
PCA-A24
36,000 BTU/H [1-phase]
MSZFH06/09/12/15/18 MSZ-EF09/12/15/18 MSZGL06/09/12/15/18/24
MFZ-KJ 09/12/ 15/18
MLZ-KP 09/12/18
SLZ-KF09/12/15 PLA-A18
SEZ-KD09/12/15/18 PEAD-A12/18/24
SVZ-KP12/18/ 24/30/36
PCA-A24
42,000 BTU/H [1-phase]
MSZFH06/09/12/15/18 MSZ-EF09/12/15/18 MSZGL06/09/12/15/18/24
MFZ-KJ 09/12/ 15/18
MLZ-KP 09/12/18
SLZ-KF09/12/15 PLA-A18
SEZ-KD09/12/15/18 PEAD-A12/18/24
SVZ-KP12/18/ 24/30/36
PCA-A24
48,000 BTU/H [1-phase]
MSZFH06/09/12/15/18 MSZ-EF09/12/15/18 MSZGL06/09/12/15/18/24
MFZ-KJ 09/12/ 15/18
MLZ-KP 09/12/18
SLZ-KF 09/12/15 PLA-A 12/18/24/30/36
SEZ-KD 09/12/15/18 PEAD-A 12/18/24/30/36
SVZ-KP12/18/ 24/30/36
60,000 BTU/H [1-phase]
MSZFH06/09/12/15/18 MSZ-EF09/12/15/18 MSZGL06/09/12/15/18/24
MFZ-KJ 09/12/ 15/18
MLZ-KP 09/12/18
SLZ-KF 09/12/15 PLA-A 12/18/24/30/36
SEZ-KD 09/12/15/18 PEAD-A 12/18/24/30/36
SVZ-KP12/18/ 24/30/36
20,000 BTU/H [1-phase]
MSZ-FH06/09/12/15 MSZ-EF09/12/15 MSZ-GL06/09/12/15
MFZ-KJ 09/12/15
MLZ-KP 09/12
SLZ-KF09/12
SEZ-KD09/12/15 PEAD-A12
SVZ-KP12
24,000 BTU/H [1-phase]
MSZFH06/09/12/15/18 MSZ-EF09/12/15/18 MSZGL06/09/12/15/18
MFZ-KJ 09/12/15/18
MLZ-KP 09/12/18
SLZ-KF09/12/15 PLA-A18
SEZ-KD09/12/15/18 PEAD-A12/18
SVZ-KP12/18
30,000 BTU/H [1-phase]
MSZFH06/09/12/15/18 MSZ-EF09/12/15/18 MSZGL06/09/12/15/18/24
MFZ-KJ 09/12/15/18
MLZ-KP 09/12/18
SLZ-KF09/12/15 PLA-A18
SEZ-KD09/12/15/18 PEAD-A12/18/24
SVZ-KP 12/18/24
36,000 BTU/H [1-phase]
MSZFH06/09/12/15/18 MSZ-EF09/12/15/18 MSZGL06/09/12/15/18/24
MFZ-KJ 09/12/15/1
MLZ-KP 09/12/18
SLZ-KF09/12/15 PLA-A12/18/ 24/30/36
SEZ-KD 09/12/15/18 PEAD-A12/18/ 24/30/36
SVZ-KP 12/18/24/30/36
42,000 BTU/H [1-phase]
MSZFH06/09/12/15/18 MSZ-EF09/12/15/18 MSZGL06/09/12/15/18/24
MFZ-KJ 09/12/15/18
MLZ-KP 09/12/18
SLZ-KF09/12/15 PLA-A12/18/ 24/30/36
SEZ-KD 09/12/15/18 PEAD-A12/18/ 24/30/36
SVZ-KP 12/18/24/30/36
48,000 BTU/H [1-phase]
MSZFH06/09/12/15/18 MSZ-EF09/12/15/18 MSZGL06/09/12/15/18/24
MFZ-KJ 09/12/15/18
MLZ-KP 09/12/18
SLZ-KF09/12/15 PLA-A12/18/ 24/30/36
SEZ-KD 09/12/15/18 PEAD-A12/18/ 24/30/36
SVZ-KP12/18/ 24/30/36
*3 The number of indoor units are limited when connected to PLA. For more information, please refer to pg.85-86 The number of ducted models (SVZ, SEZ, PEAD) connectable may be limited based on the outdoor unit and combination - refer to the compatibility charts.
Multi-position Ceiling Air Handler Suspended
PCA-A24
9
P-Series
COOLING ONLY Models (PUY) Model Name
12,000 BTU/H PLA Model
4-way Ceiling Cassette
PKA Model Wall Mount
18,000 BTU/H
24,000 BTU/H
30,000 BTU/H
36,000 BTU/H
42,000 BTU/H
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
PVA Model Multi-position Air Handler
PEAD Model Horizontal Ducted
PCA Model Ceilingsuspended
HEAT PUMP Models (PUZ) Model Name PLA Model 4-way Ceiling Cassette
PKA Model Wall Mount
12,000 BTU/H
18,000 BTU/H
24,000 BTU/H
30,000 BTU/H
36,000 BTU/H
42,000 BTU/H
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
PVA Model Multi-position Air Handler
PEAD Model Horizontal Ducted
PCA Model Ceilingsuspended
10
HYPER-HEATING Models (PUZ-HA) Model Name
24,000 BTU/H PLA Model
4-way Ceiling Cassette
PKA Model Wall Mount
30,000 BTU/H
36,000 BTU/H
42,000 BTU/H
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
PVA Model Multi-position Air Handler
PEAD Model Horizontal Ducted
PCA Model Ceilingsuspended
11
QUALITY AND TESTING Quality First. Always.
Cutting-edge technologies and uncompromising commitment to quality and reliability have made us one of the world’s most trusted brands in air-conditioning and refrigeration equipment and service.
DEVELOPMENT Operating Tests in Harsh Conditions Harsh environmental conditions of cold regions are simulated for the development of our air conditioners. This is another reason customers in severely cold regions rely on us for comfortable heating.
Combustion Test Products are subjected to a wide range of tests including combustion testing, all to confirm safe operation under a variety of conditions. Combustion testing is done by assuming accidental firing and replicating abnormal conditions that cause breakage of pressure components.
Explosion-proof chamber
Shock Resistance On the assumption of many different kinds of logistics environments in the world,we perform drop/strength tests, transport vibration tests, and many other product checks to assure that the quality and performance are maintained when the product reaches the user’s home.
Drop/strength testing
12
Transport vibration testing
Waterproof and Corrosion Test
Operation Noise Test
Since the outdoor unit is subject to rain, wind, and corrosive substances, potential problems are checked by tests such as showering the unit for a certain amount of time and increasing protection to enhance the lifespan of the unit.
Operation noise tests are performed in an anechoic chamber with an extremely low 10dB(A) of background noise. This is just one of the ways we ensure our customers enjoy extremely quiet air conditioners with a minimum operation noise of 19dB(A) (sound pressure level).
Anechoic chamber
DESIGN Designed to create and maintain a comfortable environment To improve the quality of products, engineers strive to achieve our philosophy of combining comfort and ecology in an effort to continually raise the bar. Therefore, we are working to further improve quality at all stages from development to production.
PRODUCTION Each and every unit is checked and double-checked by experienced professionals Every air conditioner goes through a rigorous electrical inspection on the manufacturing line. In final testing, our experienced inspectors listen for even the faintest operation noise to detect any defect.
13
INVERTER TECHNOLOGIES
Our Promise: Mitsubishi Electric inverters ensure superior performance including the optimum control of operation frequency. As a result, optimum power is applied in all heating/cooling ranges and maximum comfort is achieved while consuming minimal energy. Fast, comfortable operation and amazingly low running cost — that’s the Mitsubishi Electric promise.
INVERTERS – HOW THEY WORK
Inverters electronically control the electrical voltage, current and frequency of electrical devices such as the compressor motor in an air conditioner. They receive information from sensors monitoring operating conditions, and adjust the revolution speed of the compressor, which directly regulates air conditioner output. Optimum control of operation frequency results in eliminating the consumption of excessive electricity and providing the most comfortable room environment.
ECONOMIC OPERATION
Impressively low operating cost is a key advantage of inverter air conditioners. We’ve combined advanced inverter technologies with cuttingedge electronics and mechanical technologies to achieve a synergistic effect that enables improvements in heating/cooling performance efficiency. Better performance and lower energy consumption are the result.
TRUE COMFORT
Below is a comparison of air conditioner operation control with and without an inverter.
Inverter operation comparison
Non-inverter air conditioner
On/Off operation of compressor keeps room temperature
Inverter air conditioner
ON
OFF
ON
getting too hot
Compressor operation
Change in room temperature
OFF
Preset temperature
Preset temperature
Change in room temperature Full power
Optimum control of frequency keeps pre-set room temperature
ON
Minimum power consumption
Constant room temperature
getting too cool
Time
Compressor operation
Time
The compressors of air conditioners without an inverter start and stop repeatedly in order to maintain the pre-set room temperature. This repetitive on/off operation uses excessive electricity and compromises room comfort. The compressors of air conditioners equipped with an inverter run continuously; the inverter quickly optimizing the operating frequency according to changes in room temperature. This ensures energy-efficient operation and a more comfortable room. POINT 1
Quick & Powerful
POINT 2
Increasing the compressor motor speed by controlling the operation frequency ensures powerful output at start-up, brings the room temperature to the comfort zone faster than units not equipped with an inverter. Hot rooms are cooled, and cold rooms are heated faster and more efficiently.
Room Temperature Maintained
The compressor motor operating frequency and the change of room temperature are monitored to calculate the most efficient waveform to maintain the room temperature in the comfort zone. This eliminates the large temperature swings common with non-inverter systems, and guarantees a pleasant, comfortable environment.
KEY TECHNOLOGIES
14
Our Rotary Compressor
Our Scroll Compressor
Our rotary compressors use our original Poki-Poki Motor and Heat Caulking Fixing Method to realize downsizing and higher efficiency, and are designed to match various usage scenes in residential and commercial applications. Additionally, development of an innovative production method known as “Divisible Middle Plate” realizes further size/weight reductions and increased capacity while also answering energy-efficiency needs.
Our scroll compressors are equipped with an advanced frame compliance mechanism that allows self-adjustment of the position of the orbiting scroll according to pressure load and the accuracy of the fixed scroll position. This minimizes gas leakage in the scroll compression chamber, maintains cooling capacity and reduces power loss.
MORE ADVANTAGES WITH OUR PRODUCTS Joint Lap DC Motor
Vector-Wave Eco Inverter
Mitsubishi Electric has developed a unique motor, called the Poki-Poki Motor in Japan, which is manufactured using a joint lapping technique. This innovative motor operates based on a high-density, high-magnetic force, leading to extremely high efficiency and reliability.
This inverter monitors the varying compressor motor frequency and creates the most efficient waveform for the motor speed. As a result, operating efficiency in all speed ranges is improved, less power is used and annual electricity cost is reduced. Smooth wave pattern
Magnetic Flux Vector Sine Wave Drive This drive device is actually a microprocessor that converts the compressor motor’s electrical current waveform from a conventional waveform to a sine wave (180°conductance) to achieve higher efficiency by raising the motor winding utilization ratio and reducing energy loss.
Reluctance DC Rotary Compressor DC compressor motor (rotor)
Powerful neodymium magnets are used in the rotor of the reluctance DC motor. More efficient operation is realized by strong magnetic and reluctance torques produced by the magnets.
Neodymium magnets
+
Reluctance torque
Highly Efficient DC Scroll Compressor Higher efficiency has been achieved by adding a frame compliance mechanism to the DC scroll compressor. The mechanism allows movement in the axial direction of the frame supporting the cradle scroll, thereby greatly reducing leakage and friction loss, and ensuring extremely high efficiency at all speeds. Fixed scroll
Frame can move in direction of axis
Leakage loss (minimum) Thrust gas power (minimum)
Thrust friction loss (minimum) Secondary back-pressure chamber minimizes thrust friction loss
Substantial
reduction in leakage
and friction loss
Primary back-chamber minimizes leakage loss Frame
Heat Caulking Fixing Method
PAM (Pulse Amplitude Modulation) PAM is a technology that controls the current waveform so that it resembles the supply voltage wave, thereby reducing loss and realizing more efficient use of electricity. Using PAM control, 98% of the input power supply is used effectively. Supply voltage
With PAM control
Without PAM control
Time
Current
Magnetic torque
Sine-wave drive soft PWM
Inverter size has been reduced using insert-molding,where the circuit pattern is molded into the synthetic resin. To ensure quiet operation, soft PWM control is used to prevent the metallic whine associated with conventional inverters.
Time
PAM adjusts the form of the current wave so that it becomes close to that of the supply voltage wave. High harmonics are reduced and 98% of the electricity is utilized.
Merits of PAM Control Significant energy savings Remarkable reduction in power loss saves electricity
Limited energy savings Electricity is wasted
Power increased Efficient voltage increase realizes increased power
PAM
Conventional inverter Limited power Insufficient power when needed
Power Receiver and Twin LEV Control Mitsubishi Electric has developed a power receiver and twin linear expansion valves (LEVs) circuit that optimize compressor performance. This technology ensures optimum control in response to operating waveform and outdoor temperature. Operating efficiency has been enhanced by tailoring the system to the characteristics of R410A refrigerant.
Cradle scroll
Heat Caulking Fixing Method
To fix internal parts in place, a Heat Caulking Fixing Method is used, replacing the former arc spot welding method. Distortion of internal parts is reduced, realizing higher efficiency.
DC Fan Motor A highly efficient DC motor drives the fan of the outdoor unit. Efficiency is much higher than an equivalent AC motor.
Heat exchanger Power receiver LEV1
Grooved Piping High-performance grooved piping is used in heat exchangers to increase the heat exchange area.
Compressor
Heat exchanger LEV2
Grooved piping
Pipe Image Cross Sectional View
15
FEATURES 3D i-see Sensor® for M-Series The FH Model is equipped with 3D i-see Sensor®, an infraredray Sensor that measures the temperature at distant positions. While moving to the left and right, eight vertically arranged Sensor elements analyze the room temperature in three dimensions. This detailed analysis makes it possible to judge where people are in the room, thus allowing creation of features such as Indirect Airflow, to avoid airflow hitting people directly, and Direct Airflow to deliver airflow to where people are located in the space.
Indirect Airflow The Indirect Airflow setting can be used when the flow of air feels too strong or direct. For example, it can be used during cooling to avert airflow and prevent body temperature from becoming excessively cooled.
Direct Airflow This setting can be used to directly target airflow at people such as for immediate comfort when coming indoors on a hot (cold) day.
Sensor with eight elements
Absence Detection The Sensors detect whether there are people in the room. When no-one is in the room the unit automatically switches to energy-saving mode.
8 × 94 areas Sensor measures while
moving to the left to right
Divided into 94
The 3D i-see Sensor detects people’s absence and the power consumption is automatically reduced approximately 10% after 10 minutes and 20% after 60 minutes.
for SLZ and PLA Models Detects number of people The 3D i-see Sensor detects the number of people in the room and adjusts the power accordingly. This makes automatic power-saving operation possible in places where the number of people changes frequently. Additionally, when the area is continuously unoccupied, the system switches to a more enhanced power-saving mode. Depending on the setting, it can also stop the operation.
Detects number of people
Detects people’s position
Detects people’s position
Detects position and number of people Detects floor temperature
Once a person is detected, the angle of the vane is automatically adjusted. Each vane can be independently set to Direct Airflow or Indirect Airflow according to preference.
8 sensors
360°
Detection
8 ft. 23 ft. 3 ft. 39ft.
8
Highly accurate people detection A total of eight Sensors rotate a full 360° in 3-minute intervals. In addition to detecting human body temperature, our original algorithm also detects people’s positions and the number of people in the space.
16
7
6
4
53
2
1
1
2
3
4
5
6
7
8
Floor surface
*In case of a 8 ft. ceiling
Detects number of people Room occupancy energy-saving mode The 3D i-see Sensor detects the number of people in the room. It then calculates the occupancy rate based on the maximum number of people in the room up to that point in time in order to save airconditioning power. When the occupancy rate is approximately 30%, air-conditioning power equivalent to 2° F during both cooling and heating operation is saved. The temperature is controlled according to the number of people.
Room occupancy energy save mode
2° F power savings No occupancy energy save mode
No occupancy energy-saving mode When 3D i-see Sensor detects that no one is the room, the system is switched to a pre-set power-saving mode. If the room remains unoccupied for more than 60 min, air-conditioning power equivalent to 4° F during both cooling and heating operation is saved. This contributes to preventing waste in terms of heating and cooling.
4° F power savings No occupancy Auto-Off mode
Auto-Off
No occupancy Auto-OFF mode *PAR-40MAAU is required for each setting
When the room remains unoccupied for a pre-set period of time, the air conditioner turns off automatically, thereby providing even greater power savings. The time until operation is stopped can be set in intervals of 10 min, ranging from 60 to 180 min.
Detects people’s position Direct/Indirect settings*
Seasonal airflow*
The horizontal airflow spreads across the ceiling. When set to Indirect Airflow that uncomfortable drafty-feeling is eliminated completely!
When Cooling Saves energy while keeping a comfortable effective temperature by automatically switching between ventilation and cooling. When a preset temperature is reached, the air conditioning unit switches to swing fan operation to maintain the effective temperature. This clever function contributes to keeping a comfortable coolness.
*PAR-40MAAU is required for each setting.
Area Temperature Monitor The 3D i-see Sensor monitors the whole room in sections and directs the airflow to areas of the room where the temperature does not match the temperature setting. (When cooling the room, if the middle of the room is detected to be hotter, more airflow is directed towards it.) This eliminates unnecessary heating /cooling and contributes to lower electricity costs.
When Heating
The air conditioning unit automatically switches between circulator and heating. Wasted heat that accumulates near the ceiling is re-used via circulation. When a pre-set temperature is reached the air conditioner switches from heating to circulator and blows air in the horizontal direction. It pushes down the warm air that has gathered near the ceiling to people’s height, thereby providing smart heating.
Cooling
Heating
*PAR-40MAAU is required for each setting.
Cooling mode
Daytime
Warmer area
Nighttime
Cooler area
17
ENERGY-SAVING Econo Cool Energy-Saving Feature Econo Cool is an intelligent temperature control feature that adjusts the amount of air directed towards the body based on the air-outlet temperature. The setting temperature can be raised by as much as 4° F without any loss in comfort, thereby realizing a 20% gain in energy efficiency. (Function only available during manual cooling operation.) Conventional
Econo Cool
Ambient Temperature
95° F
95° F
Set Temperature
77° F
81° F
Perceived Temperature
86° F
85° F
Econo Cool Mode A comfortable room environment is maintained even when setting the temperature 4° F higher than the conventional cooling mode. Econo Cool on
Conventional cooling mode
Demand Function (Onsite Adjustment) The demand function can be activated when the unit is equipped with a commercially available timer or an On/Off switch is added to the CNDM connector (option) on the control board of the outdoor unit. Energy consumption can be reduced up to 100% of the normal consumption according to the signal input from outside. [Example: P-Series] Limit energy consumption by changing the settings of SW7-1, SW1 and SW2 on the control board of the outdoor unit. The following settings are possible. SW7-1
ON
SW1
SW2
Energy Consumption
OFF
OFF
100%
ON
OFF
75%
ON
ON
50%
OFF
ON
0% (Stop)
* PUY/PUZ outdoor only
Blue Fin
Blue Fin Heat Exchanger
Anti-corrosion treatment is done to the heat exchanger of the outdoor units. This coating prevents the corrosion of the aluminum fins caused by salt in the air especially in coastal areas. (Corrosion of the heat exchanger will effect the efficiency and performance of the air conditioner.)
Temperature distribution (° F) 58 61 64 68 72 75 79 82
AIR QUALITY Nano Platinum
Nano Platinum Filter
This filter has a large capture area and incorporates nanometersized platinum-ceramic particles that work to kill bacteria and deodorize the circulating air.
Catechin Filter Catechin is a bioflavonoid by-product of green tea with both antiviral and antioxidant qualities. In addition to improving air quality, it prevents the spreading of bacteria and viruses throughout the room, and also has an excellent deodorizing effect. Air Filter
Air Filter
This filter can remove dust particles from the air. Deodorizing Filter
Deodorizing Filter
The catalyst coating on the honeycomb-structured frame captures small foul-smelling substances in the air, then breaks down the source of the odors with the power of the ozone generated in a plasma electrode unit.
Electrostatic Anti-Allergy Enzyme Filter This filter is charged with static electricity, enabling it to attract and capture dust particles that regular filters cannot capture. This filter can also trap allergens such as molds and bacteria and decompose them using enzymes retained in the filter.
18
Air Purifying
Air Purifying Filter
The filter has a large capture area and deodorize the circulating air.
Fresh-air Intake Indoor air quality is enhanced by the direct intake of fresh exterior air.
High-efficiency Filter This high-performance filter has a much finer mesh compared to standard filters, and is capable of capturing minute particulates floating in the air that were not previously caught.
Oil Mist Filter The oil mist filter prevents oil mist from penetrating into the inner part of the air conditioner.
Long-life Filter A special process for the entrapment surface improves the filtering effect, making the maintenance cycle longer than that of units equipped with conventional filters.
Filter Check Signal Air conditioner operating time is monitored, and the user is notified when filter maintenance is necessary.
AIR DISTRIBUTION Double Vane
Double Vane
Vertical Vane
Double vane separates the airflow in the different directions to deliver airflow not only across a wide area of the room, but also simultaneously to two people in different locations.
Natural Flow
High Ceiling Mode
Natural Flow Operation
Airflow will become more like natural wind. An occupant will not be directly exposed to the airflow and feel more comfortable.
Indirect/Direct Mode
In the case of rooms with high ceilings, the outlet-air volume can be increased to ensure that air is circulated all the way to the floor.
Low Ceiling Mode
This mode offers finely-tuned operation by locating where an occupant is in the room and sends the air directly or indirectly according to the selected mode. POWERFUL MODE
The air outlet fin swings from side to side so that the airflow reaches every part of the room.
Powerful Operation
If the room has a low ceiling, the airflow volume can be reduced for less draft.
Auto Fan Speed Mode
The air conditioner will automatically adjust the fan speed and set temperature for 15 minutes. Rapid cooling and heating will make the room comfortable more quickly.
Wide Airflow
The airflow speed mode adjusts the fan speed of the indoor unit automatically according to the present room conditions.
Auto Vane Control
Especially beneficial for large spaces, helping to ensure that the air is well circulated and reaches every corner of the room. Select the desired airflow pattern and it will distribute air horizontally over a wide-ranging 150° in heating mode and 100° in cooling mode.
Outlet vanes can be moved left and right, and up and down using the remote controller. This improved airflow control feature solves the problem of drafts.
Horizontal Vane The air outlet vane swings up and down so that the airflow is spread evenly throughout the room.
BLUE FIN COATING Blue Fin
Blue Fin Heat Exchanger
Anti-corrosion treatment is done to the heat exchanger of the outdoor units. This coating prevents the corrosion of the aluminum fins caused by salt in the air especially in coastal areas. (Corrosion of the heat exchanger will effect the efficiency and performance of the air conditioner.)
Compatibility: Outdoor Unit
Blue Fin Coating
MUZ-FH
•
MUFZ-KJ
•
MUZ/Y-GL
•
MUZ-HM
•
Standard HEX coatings: Rated for 240 hours spraying time*
MUZ-JP
•
MUZ-WR
•
Blue Fin HEX coatings: Rated for 960 hours spraying time*
SUZ-KA-NA2 (9,12,15)
•
SUZ-KA-NAHZ
•
PUZ/Y-BS (sea coast protection models only)
•
MXZ-NA2/NAHZ2 Multi-zone (branch box type)
•
*Per JRA 9002 Standard Coating is applied on all M-Series single-zone outdoor units
19
CONVENIENCE Smart Set
Smart Set
Smart Set is a simplified setting function that recalls the preferred (pre-set) temperature by pressing a single button on the remote controller. Press the same button twice in repetition to immediately return to the previous temperature setting. Using this function contributes to comfortable waste-free operation, realizing the most suitable air conditioning settings and saving on power consumption when, for example, leaving the room or going to bed.
Heating
70° F
Heating
65° F
Auto Changeover The air conditioner automatically switches between heating and cooling modes to maintain the desired temperature.
Low-temperature Cooling Intelligent fan speed control in the outdoor unit ensures optimum performance even when the outside temperature is low.
Ampere Limit Adjustment Dip switch settings can be used to adjust the maximum electrical current for operation. This function is highly recommended for managing energy costs. *Maximum capacity is lowered with the use of this function.
Auto Restart Especially useful at the time of power outages, the unit turns back on automatically when power is restored.
20
Smart Set
Outdoor
Operation Lock (Outdoor unit)
To accommodate specific-use applications, cooling or heating operation can be specified when setting the control board of the outdoor unit. A convenient option when a system needs to be configured for exclusive cooling or heating service.
Sleep
Sleep Mode
When Sleep Mode is activated using the wireless remote controller, it will switch to the settings described below. • After 30 minutes, the set temperature will automatically change to the sleep mode set temperature which the user can set beforehand. • The fan speed will immediately change to low fan speed.
On/Off Operation Timer Use the remote controller to set the times of turning the air conditioner On/Off.
Weekly Timer Function Easily set desired temperatures and operation ON/OFF times to match lifestyle patterns. Reduce wasted energy consumption by using the timer to prevent forgetting to turn off the unit and eliminate temperature setting adjustments. Sample Operation Pattern (Winter/Heating mode)
AM
Mon.
Tues.
Wed.
Thurs.
Fri.
Sat.
Sun.
ON 68°F
ON 68°F
ON 68°F
ON 68°F
ON 68°F
ON 68°F
ON 68°F
ON 64°F
ON 64°F
Automatically changes to high-power operation at wake-up time
AM AM
OFF
AM
OFF
OFF
OFF
OFF
Midday is warmer, so the temperature is set lower
Automatically turned off during work hours
PM PM
ON 72°F
PM
ON 72°F
PM
ON 72°F
ON 72°F
ON 72°F
ON 72°F
ON 72°F
Automatically raises temperature setting to match time when outside-air temperature is low
Automatically turns on, synchronized with arrival at home
PM
(during sleeping hours)
Settings
ON 64°F
ON 64°F
ON 64°F
ON 64°F
ON 64°F
ON 64°F
ON 64°F
Automatically lowers temperature at bedtime for energy-saving operation at night
Pattern Settings: Input up to four settings for each day Settings: • Start/Stop operation • Temperature setting ✽ The operation mode cannot be set.
PUSH
Easy set-up using dedicated buttons
How to set the Weekly Timer
The remote controller is equipped with buttons that are used exclusively for setting the Weekly Timer. Setting operation patterns is easy and quick.
Ready to s
PUSH
S
Complete
PUSH
How to set the Weekly Timer
PUSH
Complete
PUSH
Select the day
Ready to set PUSH
Select ON/OFF
PUSH
Select the time
PUSH
Select the period
PUSH
Set the temperature
• Start by pushing the “SET” button and follow the instructions to set the desired patterns. Once all of the desired patterns are input, point the top end of the remote controller at the indoor unit and push the “SET” button one more time. (Push the “SET” button only after inputting all of the desired patterns into the remote controller memory. Pushing the “CANCEL” button will end the set-up process without sending the operation patterns to the indoor unit). • It takes a few seconds to transmit the Weekly Timer operation patterns to the indoor unit. Please continue to point the remote controller at the indoor unit until all data has been sent.
21
SYSTEM CONTROL System Group Control
M-NET Connection
The same remote controller is capable of controlling the operational status of up to 16 refrigerant systems.
kumo cloud® Wireless Interface Along with your smart phone or tablet device, you can manage your system in multiple venues, such as home, work and vacation locations. You can control functions like turning on/off, fan speed, and vane direction.
Units can be connected to MELANS system controllers (M-NET controllers) such as the AE-200A.
MXZ Connection Connection to the MXZ multi-split outdoor unit is possible.
® Wireless Interface 2
Apple and the App Store are registered trademarks of Apple, Inc.
Amazon, Alexa, Fire and all related logos are trademarks of Amazon.com, Inc. or its affiliates. Google play is a registered trademark of Google, Inc.
Manage Your Comfort From Anywhere With kumo cloud • • • • • • • • • • •
Now compatible with M-Series, P-Series and CITY MULTI® systems kumo cloud allows for a Mitsubishi Electric indoor unit to be controlled remotely or locally with the app For product information go to kumocloud.com Ability to group units and organize groups into sites Batch command units Ability to program events and scheduling into the unit itself Available in Fahrenheit or Celsius Easy to connect the device to your router using the kumo cloud app Each indoor unit must be equipped with a Mitsubishi Electric Wireless Interface (PAC-USWHS002-WF-2) installed by a licensed contractor Secure boot to prevent unauthorized reprogramming of Wireless Interface Intuitive initial settings feature for M- & P-Series equipment
Did you forget to turn off your unit before leaving for vacation? You don’t have a worry in the world when you have the kumo cloud app. You can change temperatures, set and store a schedule, and much more from anywhere. It really is comfort made personal. Anytime, Anywhere Control kumo cloud gives you the ability to effortlessly control your home’s comfort. Whether you’re out for the day or the month, looking to cool down or warm up, kumo cloud gives you control from any smart phone, tablet or web browser. Program and Schedules: kumo cloud walks you through a five-step process to easily schedule the mode, set temperature and fan speed, for an individual zone or several zones at once. Easily Zoned: Once your Wireless Interface is installed on your indoor unit by a trained HVAC professional, the indoor unit will discover the app. Name your indoor units, create groups, and organize multiple properties from one user-friendly app. Check Filter Status: You never have to manually check a filter again. kumo cloud can tell you the status of any filter in your system at any time.
22
kumo touch™ Simple wall-mounted design controllers can be installed anywhere with large, backlit, easy to read display. Both the controller and receiver is enabled with RedLINK reliability.
WiFi
Wireless Interface 2
kumo touch™ Controller
kumo touch™ Receiver To CN105 on Indoor Unit control board
MRCH2 kumo touch Controller Specifications
• Touch panel, Backlit, easy-to-read display • Used RedLINK™ 3.0 wireless technology - Not compatible with MHK1, MOS1, and MCCH1 RedLINK 2.0 wireless technology environment • User functions allow user to set: - On/Off - Operation modes cool, heat, drying, fan - Set temperature (separate dual set points for heat and cool) - Fan speed setting - Airflow direction • Set temperature range limits (dependent on the system connected): - Cooling from 50° to 99° F - Heating from 40° to 90° F - Auto from 50° to 90° F with dual temperature setting • MHK2 Scheduling options: - No Schedule - MO-SU = Every day the same - MO-FR, SA, SU = 5-1-1 schedule - MO-FR, SA-SU = 5-2 schedule - Each Day = Every day individual - Allow kumo cloud to be schedule holder • Hold function • Temporary or Permanent schedule override • Lockout: - On, Off, Mode, Fan Speed, Set point, Vane Direction • Day/Time display with a 12 or 24-hour clock • Supports both Fahrenheit and Celsius • RedLINK™ Wireless Connection Status • Filter sign display • Diagnostics: Displays and records error codes • Adjustable auto mode deadband • Space temperature offset adjustment • Space humidity offset adjustment • Hide (on screen only) - Indoor temperature - Indoor humidity
MHK2
• Temperature Sensing Source - MHK2 - Indoor Unit - RedLINK Wireless Indoor Air Sensor (IAS) - Average of MHK2 and RedLINK Wireless Indoor Air Sensor (IAS) • Indoor Humidity Source - MHK2 - RedLINK Wireless Indoor Air Sensor (IAS) - Average of MHK2 and RedLINK Wireless Indoor Air Sensor (IAS) • Improved indoor unit function code list - Indoor unit type - Expanded to 28 indoor unit codes • Reset to factory default • Uses two “AA” alkaline batteries (included) • Dimensions: 4-5/64” x 4-5/64” x 1-1/16” (104 x 104 x 27 mm) • Operating Ambient Temperature: 32° to 120° F (0° to 48.9° C) • Operating Relative Humidity: 5% to 90%
MIFH2 WIRELESS RECEIVER SPECIFICATIONS:
• Included in MHK2 Kit • Mounts next to or near indoor units to allow MRCH2 Remote Controller operation • Connects to indoor unit control board with MRC2 Cable • Dimensions: 3-3/32” H x 1-3/4” W x 39/64” D (74.8 x 44.4 x 15.4 mm) • Operating Ambient Temperature: -40° to 165° F (-40° to 73.9° C) • Operating Relative Humidity: 5% to 95%
MRC2 CABLE
• Included in MHK2 Kit in the MIFH2 box • Connects MIFH2 Wireless Receiver to the CN105 connector on indoor unit control board • Length: 39-23/64" (1 m)
23
WIRED CONTROLLERS Simple MA Remote Controller • Controls group operation for up to 16 indoor units in a single group • Supports Fahrenheit and Celsius • User defined functions: - On/Off - Operation modes: Heat/Cool/Auto/Dry - Fan speed setting - Airflow direction - Set temperature range: 40° F to 95° F depending on operation mode and indoor unit connected • Set temperature range limit for cool and heat modes • LOSSNAY©: Simple MA for interlocked system can set high/low/stop on LOSSNAY • Room temperature can be sensed either at indoor unit (default) or at the remote controller • Dimensions: 2-3/4″ W x 9/16″ D x 4-3/4″ H • Requires MAC-334IF-E for use with M-Series products
PAC-YT53CRAU-J
Deluxe MA Remote Controller • User defined functions: - On/Off - Operation modes: Heat/Cool/Auto/Dry - Room temperature setting & Temperature range restriction - Manual vane angle (P-Series cassette indoor units) - Smooth maintenance (P-Series only) - Auto-off timer & Weekly timer • Setting screen for 3D i-see Sensor® • Draft reduction mode • Daylight Saving Time (DST) • Dimensions: 4-3/4″ W x 3/4″ D x 4-3/4″ H • Requires MAC-334IF-E for use with M-Series ductless products • Room temperature displays room temperature sensed either at the indoor unit (default) or at the controller
PAR-40MAAU
Touch MA Remote Controller • • • • • • •
User-friendly, customizable full color touch panel display Ability to add a custom logo on the display Large icons with 180 color patterns Daily and weekly timers Password protected Requires MAC-334IF-E for use with M-Series products The MELRemo app and Bluetooth® Low Energy (BLE) technology supports communication with smartphones or tablets in multiple languages
PAR-CT01MAU-SB
24
INTERFACE DEVICES T-STAT
• • • • • •
Control your Zoned Comfort Solution using a third-party 24VAC transformer Wires back to the indoor unit using CN105 to replace the return air temperature sensor Maximum wiring length: 39′ (12 m) Dimensions: 3.17 in (w) x 3.96 in (h) x 0.93 in (d) (80.6 x 100.6 x 23.7 mm) Exterior shell made of ABS resin Environment Conditions — operating temperature range: Installation manual states that the temperature should be between 32° F and 104° F (0° C to 40° C)
BACnet • • • • • •
Thermostat Interface
PAC-US444CN-1
BACnet® Interface
Allows for third-party home automation/building management system to control indoor unit One interface required per indoor unit Compatible with remote controllers Dimensions: 3.74" x 2" x 0.75" Cable length: 37" Allows for third-party home automation/building management system to control indoor unit
PAC-UKPRC001-CN-1
USNAP
USNAP Interface
• Allows indoor units to participate in demand response events • Works with CTA 2045 DC Form Factor Universal Communication Modules (UCMs) • 3 LEDs to display device status - Communication with UCM - Communication to indoor unit - Demand Response Events • System Reset
PAC-WHS01UP-E
MAC-334IF-E System Control Interface • Allows M-Series indoor units to communicate with the CITY MULTI® Controls Network via M-NET • Provides an input to allow remote On/Off control of indoor unit • Allows M-Series indoor units to connect to MHK2 Wall-Mounted Wireless Controller when using other MAC-334IF-E functions • Allows M-Series indoor units to connect to a MA controller • Power: 12V DC (supplied from indoor unit)
MAC-334IF-E
25
FEATURES MSZ-FH06/09/12/15NA MSZ-FH18NA2 MXZ-4C
MXZ-5C
MXZ-8C
MXZ-2C
MXZ-3C
MXZ-4C
MXZ-5C
MXZ-8C
MUZ-GL
MXZ-2C
MXZ-3C
MXZ-4C
MXZ-5C
MXZ-8C
MSZ-GL06/09/12/15/18/24NA
MXZ-3C
MSZ-EF09/12/15/18NA(W)(B)(S)
MXZ-2C
Energy Saving
Indoor unit MUZ-FH
i-see Sensor
Icon
Radiant Temperature Control (3D i-see Sensor®)
•
•
•
•
•
•
AREA Temperature Monitor
•
•
•
•
•
•
Econo Cool
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Nano Platinum Filter
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Deodorizing Filter
•
•
•
•
•
•
Electrostatic Anti-Allergy Enzyme Filter
•
•
•
•
•
•
•
•
•
•
•
24
24
24
24
24
24
Outdoor Unit
Category
Combination
M-Series
Catechin Filter Air Cleaning Filter Air Quality
06-18 06-18 06-18 06-18 06-18 06-18
Anti-Allergy Enzyme Filter
Functions
Air Purifying Filter
Air Distribution
Double Vane
•
•
•
•
•
•
Horizontal Vane
•
•
•
•
•
•
Vertical Vane
•
•
•
•
•
•
Natural Flow Operation
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
18/24 18/24 18/24 18/24 18/24 18/24
Wide Airflow
Convenience
•
24
24
24
24
24
24
24
24
24
24
24
24
Indirect/Direct Airflow
•
•
•
•
•
•
Powerful Operation
•
•
•
•
•
•
Smart Set
•
•
•
•
•
•
•
•
•
•
•
Auto Restart
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Low Temperature Cooling
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
24H On/Off Operation Timer
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Weekly Timer
•
•
•
•
•
•
•
•
•
•
•
Blue Fin
•
06-18 06-18 06-15 06-18 06-18 06-18
Sleep Mode 12H On/Off Operation Timer
Maintenance
• * 1 • *1
•
*1 Branch box units only: MXZ-8C48NA2, MXZ-8C60NA2, MXZ-4C36HNHZ2, MXZ-5C42HNHZ2, and MXZ-8C48HNHZ2 *2 Sea coast protection models only (-BS)
26
• * 1 • *1
•
•
• * 1 • *1
•
M-Series
MXZ-5C
MXZ-8C
SUZ-KA
MXZ-2C
MXZ-3C
MXZ-4C
MXZ-5C
MXZ-8C
•
•
•
•
•
•
•
•
•
•
•
•
•
•
• •
•
•
•
•
•
•
•
•
MXZ-8C
MXZ-4C
•
MXZ-5C
MXZ-3C
•
MXZ-4C
MXZ-2C
•
MXZ-3C
MUFZ-KJ
•
MXZ-2C
MUZ-JP
SVZ-KP12/18/24/30/36NA
MUZ-WR
MLZ-KP09/12/18NA
MUY-D
MFZ-KJ09/12/15/18NA
SUZ-KA
MSZ-WR MSZ-JP 09/12/ 09/ 18/24NA 12WA
MUY-GL
MSY-D 30/ 36NA
MUZ-HM
MSZ-HM MSY-GL 09/12/15/ 09/12/15/ 18/24NA 18/24NA
MUZ-D
MSZ-D 30/ 36NA
•
•
•
•
•
•
• • 24
•
Opt
09-18
•
•
•
•
18/24
•
24
•
•
24
•
•
•
Opt
•
•
•
Opt
•
Opt
•
Opt
•
Opt
•
Opt
•
•
18/24
06-18
•
•
•
•
•
•
•
•
•
•
Opt
Opt
Opt
Opt
Opt
Opt
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
• •
• •
•
•
• •
• •
•
• *1 • *1
• * 1 • *1
•
•
• * 1 • *1
•
Opt: Separate parts must be purchased.
27
FEATURES M-Series
Energy Saving
MXZ-3C
MXZ-4C
MXZ-5C
MXZ-8C
•
•
•
•
MXZ-8C
•
MXZ-5C
•
MXZ-4C
•
MXZ-3C
AREA Temperature Monitor
MXZ-2C
•
SUZ-KA
•
MXZ-8C
•
MXZ-5C
•
MXZ-4C
•
MXZ-3C
•
MXZ-2C
•
SUZ-KA
PUZ-HA
PLA-A12/18/24/30/36/42EA7
PUY-A
Outdoor Unit
SEZ-KD09/12/15/18NA
Radiant Temperature Control (3D i-see Sensor®)
12/18/ 12/18/ 30/36 24/36 24/36
ENERGY STAR© Demand Function (PAR-33MAA)
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Long-life Filter
•
•
•
•
•
•
•
•
•
•
•
•
•
Filter Check Signal
•
•
•
•
•
•
•
•
•
•
•
•
•
Vertical Swing
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Fresh-air Intake
Air Quality
SLZ-KF09/12/15/18NA
PUZ-A
i-see Sensor
Icon
Combination
Indoor unit Category
P-Series
High-efficiency Filter
Functions
Horizontal Swing Air Distribution
High Ceiling Mode Low Ceiling Mode
Convenience
Auto Fan Speed Mode
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Auto Restart
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Low Temperature Cooling
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
• *1 • *1 •
•
12H On/Off Operation Timer 24H On/Off Operation Timer Weekly Timer Self-Diagnostic Function
Failure Recall Maintenance Function Blue Fin
•
• *1 • *1 •
*1 Branch box units only: MXZ-8C48NA2, MXZ-8C60NA2, MXZ-4C36HNHZ2, MXZ-5C42HNHZ2, and MXZ-8C48HNHZ2 *2 Sea coast protection models only (-BS)
28
• *2 • *2
• *1 • *1
•
P-Series
PUZ-A
PUY-A
PUZ-HA
Opt 12
12
30/36
12
12
30/36
•
•
•
•
•
•
MXZ-8C
MXZ-5C
Opt
MXZ-5C
MXZ-4C
Opt
MXZ-4C
MXZ-3C
Opt
MXZ-3C
PUZ-HA
Opt
MXZ-2C
PUY-A
Opt
PUZ-HA
PUZ-A
PUZ-HA
•
PVA-A12/18/24/ 30/36/42AA7
PEAD-A12/18/24/30/36/42AA7
PUY-A
•
PCA-A24/30/36/42KA7
PUZ-A
•
PUY-A
PUZ-A
PKA-A12/18HA7 PKA-A24/30/36KA7
•
•
•
•
•
•
•
•
•
Opt
Opt
Opt
Opt
Opt
Opt
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Opt
Opt
Opt
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
• *2
• *2
• *2
• *2
• *1
• *1
• *2
• *2
• *1
• *1
•
• *2
• *2
Opt: Separate parts must be purchased.
29
M Series
30
LINE-UP HEAT PUMP
A multiple model line-up to choose from, each with various outstanding features. In addition to inverter-equipped wall-mounted models, floor-standing and multi-position air handlers can be selected. Choose the best style to match usage needs. Wall-mounted Units
MSZ-FH Model
MSZ-EF Model
MSZ-D Model
MSZ-HM Model MSZ-JP Model
MSZ-GL Model
MSZ-WR Model
EZ FIT™ Ceiling Cassette Units
Multi-position Air Handler
Floor-mounted Units
MLZ Model
SVZ Model
MFZ Model
Ceiling Cassette Unit
Horizontal-ducted Units
SLZ Model
SEZ Model
PEAD Model
COOLING ONLY
For applications with needs for only cooling, there are cooling-only models to choose from. Wall-mounted Units
MSY-GL Model
MSY-D Model
31
MSZ-FH Model
MSZ-FH06/09/12/15NA MSZ-FH18NA2
The FH Model is designed for optimum cooling/heating performance as well as operational comfort. Quiet, energysaving operation is supported by some of our latest technologies. Advanced functions such as the 3D i-see Sensor® temperature control and Triple-action filtration raise room comfort levels to new heights.
ENERGY STAR® Certified for Entire Range of Series The FH Model has achieved an industry-leading efficiency of 33.1 SEER (MSZ-FH06NA) and 30.5 SEER (MSZ-FH09NA). All systems of the FH Model feature high efficiencies and are ENERGY STAR® qualified, meaning that these units can save up to 25% on heating and cooling costs when installed correctly.
Top class in industry! 33.1
30.5
13.5
13.5
FH06NA
Heating capacity (%)
FH15NA
-4o F
12.0
FH18NA2
Base Heater equipped as standard* The base heater restricts lowered capacity and operation shutdowns caused by the drain water freezing. This supports stable operation in low-temperature environments.
100% heating capacity as low as 5°F
Frozen drain
100%
-13o F
5o F
HSPF
21.0 12.0
FH12NA
Operation guraranteed at minus 13° F, 100% heating capactiy at 5° F
19o F
Drain does not freeze
32o F
Without base heater
Outdoor-air temperature MUZ-FH Standard Heat Pump
32
22.0 12.5
FH09NA
Heating operation down to -13°F
SEER
26.1
With base heater *Standard for MUZ-FH**NAH models Optional for MUZ-FH**NA models
The FH Model is equipped with 3D i-see Sensor®, an infraredray Sensor that measures the temperature at distant positions. While moving to the left and right, eight vertically arranged Sensor elements analyze the room temperature in three dimensions. This detailed analysis makes it possible to judge where people are in the room, thus allowing creation of features such as Indirect Airflow, to avoid airflow hitting people directly, and Direct Airflow to deliver airflow to where people are located.
Indirect Airflow The Indirect Airflow setting can be used when the flow of air feels too strong or direct. For example, it can be used during cooling to avert airflow and prevent body temperature from becoming excessively cooled.
Direct Airflow This setting can be used to directly target airflow at people such as for immediate comfort when coming indoors on a hot (cold) day.
Sensor with eight elements
Absence Detection
8 × 94 areas
The Sensors detect whether there are people in the room. When no one is in the room the unit automatically switches to energy-saving mode.
Sensor measures while
moving to the left to right
Divided into 94
The 3D i-see Sensor detects people’s absence and the power consumption is automatically reduced approximately 10% after 10 minutes and 20% after 60 minutes.
Natural Flow To create healthy airflow, the most important aspect is that the flow of air feels natural. Our solution to this is Natural Flow, thanks to our technology that freely and flexibly controls airflow. Natural Flow (in Cooling) 104
Double Vane
68
Our double vane separates the airflow in the left and right directions to deliver airflow not only across a wide area of the room, but also simultaneously to two people in different locations.
Gentle airflow that avoids overcooling
Direct airflow (in Cooling) 104
68
Through realizing airflow that imitates a natural breeze, we have avoided the unpleasant feeling of being hit directly by constant, unnatural airflow.
Legs become too cold
Base data for Natural Flow Kirigamine Highland is one of the most famous sightseeing spots in Japan, and is visited by a large number of people for its pleasant and
comfortable environment. We have attempted to recreate this Kirigamine Highland comfort. As
part of development, seeking to create a natural
120 100 80 60
Through imitating the natural waveforms of this
20
data, we have been able to recreate
Kirigamine Highland
Wind speed [cm/s]
140
airflow, we measured actual data on the
refreshing breezes of Kirigamine Highland.
Measuring actual data of natural wind
Analysis of natural wind
almost-imperceptible currents of gently comforting airflow.
40 0
0
20
40
Wind of Kirigamine
60
80
100
120
Time [s]
Natural Flow(FH SERIES)
33
Triple-action Filtration Air, like water, is something we use every day unconsciously. Yet, clean, fresh air is a vital part of creating a healthy space for humans. Healthy air is achieved with three filters: the Nano Platinum filter, the Deodorizing filter, and the Electrostatic anti-allergy enzyme filter.
Nano Platinum Filters This filter has a large capture area and incorporates nanometer-sized platinum-ceramic particles that work to kill bacteria and deodorize the circulating air.
Deodorizing Filter This filter removes chemical substances such as ammonia, methyl mercaptan, trimethylamine and hydrogen sulphide at the nano-level (1/1,000,000 of a millimeter).
Electrostatic Anti-Allergy Enzyme Filter This filter is charged with static electricity, enabling it to attract and capture dust particles that regular filters cannot capture. Also, it can trap allergens and decompose them using enzymes retained in the filter.
Quiet Operation The indoor unit noise level is as low as 20dB(A) for FH06/09 models, offering a peaceful inside environment.
ď Ž Sound Level Human hearing limits (Extremely quiet)
10dB(A) Only
Sound of rustling leaves
20dB(A)
(for FH06/09 models)
34
Library interior
40dB(A) In-house investigation
Quiet passenger car interior (40km/h)
60dB(A)
Subway car interior
80dB(A)
Heat Caulking Fixing Method
MSZ-FH Model Indoor Unit
Outdoor Unit
Remote Controller
MUZ-FH06/09/12NA(H) MSZ-FH06/09/12/15NA MSZ-FH18NA2 MUZ-FH15NA(H) MUZ-FH18NA(H)2
* To confirm compatibility with the MXZ Model multi-zone system, refer to MXZ Model page.
Blue Fin
HUMAN
Nano Platinum
Deodorizing Filter
Electrostatic Anti-allergy
Double Vane
Natural Flow HORIZONTAL
VERTICAL
Optional
Optional
USNAP Optional
Optional
Indoor Unit Outdoor Unit
Cooling
MSZ-FH12NA
MSZ-FH15NA
MSZ-FH18NA2
MUZ-FH12NA(H)
MUZ-FH15NA(H)
MUZ-FH18NA(H)2
BTU/H
6,000
9,000
12,000
15,000
17,200
BTU/H
1,700–9,000
1,700–12,000
2,500–13,600
6,450–19,000
6,450–21,000
Power Input
Rated 1
W
315
560
870
1,200
1,375
Moisture Removal
Pints/h
0.2
0.6
1.9
4.0
4.8
0.960
0.920
0.830
0.700
0.690
Capacity at 47ºF
Rated 2
BTU/H
8,700
10,900
13,600
18,000
20,300
Capacity Range
Min-Max
BTU/H
1,600–14,000
1,600–18,000
3,700–21,000
5,150–24,000
5,150–30,000
Power Input at 47ºF
Rated 2
W
545
710
950
1,300
1,720
Rated 3
BTU/H
5,900
6,700
8,000
11,000
13,700
Max
BTU/H
10,700
12,200
13,600
18,000
20,300
Max 4
BTU/H
8,700
10,900
13,600
18,000
20,300
SEER
33.1
30.5
26.1
22.0
21.0
EER
19.1
16.1
13.8
12.5
12.5
HSPF
13.5 (12.5)
13.5 (12.5)
12.5 (11.5)
12.0 (11.0)
12.0 (11.0)
COP
4.68
4.5
4.2
4.06
3.46
ENERGY STAR® Certified
Yes
Yes
Yes
Yes
Yes
137–167–221–304–381
137–167–221–304–381
137–167–221–304–398
225–262–304–355–411
225–262–304–355–459
Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Dry
CFM
Wet
CFM
117–143–190–261–328
117–143–190–261–328
117–143–190–261–342
194–225–261–305–354
194–225–261–305–395
Dry
CFM
140–167–225–325–437
140–167–225–325–437
140–167–225–325–454
201–254–317–394–497
201–254–317–394–514
Cooling
dB(A)
20–23–29–36–40
20–23–29–36–40
21–24–29–36–41
27–31–35–39–44
27–31–35–39–47
Heating
dB(A)
20–24–29–36–42
20–24–29–36–42
21–24–29–36–42
25–29–34–39–46
25–29–34–36–46
In. W.G.
—
—
—
—
—
Condensate Lift Mechanism
External Static Pressure
Max Distance In. [mm]
—
—
—
—
—
H
In. [mm]
12 (+11/16) [305 (+17)]
12 (+11/16) [305]
12 (+11/16) [305 (+17)]
12 (+11/16) [305 (+17)]
12 (+11/16) [305 (+17)]
Dimensions
W
In. [mm]
36-7/16 [925]
36-7/16 [925]
36-7/16 [925]
36-7/16 [925]
36-7/16 [925]
D
In. [mm]
9-3/16 [234]
9-3/16 [234]
9-3/16 [234]
9-3/16 [234]
9-3/16 [234]
29 [13.5]
29 [13.5]
29 [13.5]
29 [13.5]
29 [13.5] 16.0
Weight
lbs [kg]
MCA
A
11.0
11.0
11.0
16.0
MOCP
A
15
15
15
20
20
In. [mm]
21-5/8 [550]
21-5/8 [550]
21-5/8 [550]
34-5/8 [880]
34-5/8 [880]
W
In. [mm]
31-1/2 [800]
31-1/2 [800]
31-1/2 [800]
33-1/16 [840]
33-1/16 [840]
D
In. [mm]
11-1/4 [285]
11-1/4 [285]
11-1/4 [285]
13 [330]
13 [330]
81 [37]
81 [37]
83 [38]
124 [56]
124 [56] 1692/1634
H Dimensions Weight Air Flow Rate (Cooling/Heating) Sound Pressure Level
lbs [kg]
1074/1202
1074/1202
1074/1202
1692/1634
Cooling
CFM dB(A)
47
48
49
51
52
Heating
dB(A)
48
49
51
55
55
Gas (O.D.)
In. [mm]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
Diameter
Liquid (O.D)
In. [mm]
3/8 [6.35]
3/8 [6.35]
3/8 [6.35]
1/2 [12.7]
1/2 [12.7]
Indoor Drain
In. [mm]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
Max. Length
ft [m]
65 [20]
65 [20]
65 [20]
100 [30]
100 [30]
Max. Height
ft [m]
40 [12]
40 [12]
40 [12]
50 [15]
50 [15]
Outdoor-Indoor 5
V, ph, Hz
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
Piping
Electrical
MSZ-FH09NA MUZ-FH09NA(H)
Min-Max
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi)
Outdoor Unit
MSZ-FH06NA MUZ-FH06NA(H) Rated 1
Capacity at 17ºF
Indoor Unit
Optional
Capacity Range
Capacity at 5ºF
Efficiency
T-STAT
Optional
Capacity
Sensible Heat Factor
Heating
Optional
POWERFUL MODE
Recommended Breaker Size A
Refrigerant Type Cooling 6 Guaranteed Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
ºF DB [ºC DB] ºF DB [ºC DB]
15
15
15
20
20
R410A
R410A
R410A
R410A
R410A
14.0 to 115.0 [-10.0 to 46.0] -13.0 to 75.0 [-25.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -13.0 to 75.0 [-25.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -13.0 to 75.0 [-25.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -13.0 to 75.0 [-25.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -13.0 to 75.0 [-25.0 to 24.0]
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 1 2 3
35
MSZ-EF Model Developed to complement modern interior room décor, the EF Model are available in three colors specially chosen to blend in naturally wherever installed.
MSZ-EF09/12/15/18NAB/S/W
A Stylish Line-up Matches Any Room Décor The streamlined wall-mounted indoor units have eloquent edges, expressing sophistication and quality. Combining impressively low power consumption and quiet yet powerful performance, these units provide a best-match scenario for diverse interior designs while simultaneously ensuring maximum room and energy savings.
Quiet Operation All Day Long Our advanced Quiet Mode fan speed setting provides super-quiet operation as low as 21dB(A) for EF09/12 models. This unique feature makes the EF Model ideal for use in any situation.
Sound Level Human hearing limits (Extremely quiet)
Sound of rustling leaves
10dB(A)
Library interior
Quiet passenger car interior (25mph)
40dB(A) 60dB(A)
21dB(A)
Subway car interior
80dB(A)
Only
(for EF09/12 models)
In-company investigation
Superior Exterior and Operating Design Concept The indoor unit of the EF Model keeps its amazingly thin form even during operation. The only physical change notable is the movement of the variable vent. As a result, a slim attractive look is maintained. Closed Open
36
MSZ-EF Model Indoor Unit
Outdoor Unit
Remote Controller
For MXZ Connection Only
MSZ-EF09/12/15/18NAB* MSZ-EF09/12/15/18NAS MSZ-EF09/12/15/18NAW
* To confirm compatibility with the MXZ Model multi-zone system, refer to MXZ Model page.
Glossy Black Matte Silver Glossy White
*Soft-dry Cloth is enclosed with Black models.
Nano Electrostatic Platinum Anti-allergy
USNAP Optional
Indoor Unit
Cooling
MSZ-EF12NAW(S)(B)
MSZ-EF15NAW(S)(B)
MSZ-EF18NAW(S)(B)
—
—
—
—
Capacity Range
Min-Max
BTU/H
—
—
—
—
Power Input
Rated 1
W
—
—
—
—
Moisture Removal
Pints/h
—
—
—
—
—
—
—
—
—
—
—
—
Capacity at 47ºF
Rated 2
BTU/H
Capacity Range
Min-Max
BTU/H
—
—
—
—
Power Input at 47ºF
Rated 2
W
—
—
—
— —
Rated 3
BTU/H
—
—
—
Max
BTU/H
—
—
—
—
Max 4
BTU/H
—
—
—
—
SEER
—
—
—
—
EER
—
—
—
—
HSPF
—
—
—
—
COP
—
—
—
—
ENERGY STAR® Certified
—
—
—
—
Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Dry
CFM
141–162–222–293–371
141–162–222–293–371
205–233–272–314–364
205–240–279–328–388
Wet
CFM
121–140–191–252–319
121–140–191–252–319
176–200–234–270–313
176–206–240–282–334
Dry
CFM
141–162–219–314–420
141–162–219–314–448
194–222–275–350–448
226–258–318–392–466
Cooling
dB(A)
21–23–29–36–42
21–24–29–36–42
28–31–35–39–42
30–33–36–40–43
Heating
dB(A)
21–24–29–37–45
21–24–30–38–46
28–30–35–41–48
30–33–37–43–49
In. W.G.
—
—
—
—
Max Distance In. [mm]
—
—
—
—
External Static Pressure Condensate Lift Mechanism Dimensions
H
In. [mm]
11-3/4 [299]
11-3/4 [299]
11-3/4 [299]
11-3/4 [299]
W
In. [mm]
34-13/16 [884]
34-13/16 [884]
34-13/16 [884]
34-13/16 [884]
D
In. [mm]
7-11/16 [195]
7-11/16 [195]
7-11/16 [195]
7-11/16 [195]
26 [11.8]
26 [11.8]
26 [11.8]
26 [11.8]
Weight
lbs [kg]
MCA
A
—
—
—
—
MOCP
A
—
—
—
—
Dimensions
H
In. [mm]
—
—
—
—
W
In. [mm]
—
—
—
—
D
In. [mm]
—
—
—
—
Weight
lbs [kg]
—
—
—
—
Air Flow Rate (Cooling/Heating)
CFM
—
—
—
—
Sound Pressure Level
Diameter Piping
Electrical
Optional
MSZ-EF09NAW(S)(B)
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi)
Outdoor Unit
Optional
BTU/H
Capacity at 5ºF
Indoor Unit
T-STAT Optional
Rated 1
Capacity at 17ºF
Efficiency
Optional
Capacity
Sensible Heat Factor
Heating
Optional
Cooling
dB(A)
—
—
—
—
Heating
dB(A)
—
—
—
—
Gas (O.D.)
In. [mm]
—
—
—
—
Liquid (O.D)
In. [mm]
—
—
—
—
Indoor Drain
In. [mm]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88] —
Max. Length
ft [m]
—
—
—
Max. Height
ft [m]
—
—
—
—
Outdoor-Indoor 5
V, ph, Hz
—
—
—
—
—
—
—
—
—
—
—
—
ºF DB [ºC DB]
—
—
—
—
ºF DB [ºC DB]
—
—
—
—
Recommended Breaker Size A
Refrigerant Type Guaranteed Cooling 6 Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 1 2 3
37
MSZ/MSY-GL Model MSZ/MSY-D Model Introducing a compact and stylish indoor unit with amazingly quiet performance. Not only are neat installations in small bedrooms, you can increase energy-savings by selecting the optimal capacity required for each room.
MSZ/MSY-D30/36NA MSZ/MSY-GL24NA MSZ/MSY-GL18NA MSZ-GL06/09/12/15NA MSY-GL09/12/15NA
ENERGY STARÂŽ Qualified for Entire Range of MSZ/MSY-G Model All systems of the MSZ-GL and MSY-GL Model feature high efficiencies and are ENERGY STARÂŽ qualified. 24.6
SEER
23.1 12.8
GL09
21.6 12.5
GL12
20.5
20.5 11.7
GL15
HSPF
11.2
GL18
10.0
GL24
Wide Line-up with Family Design Eight different capacities (6,000 BTU/H to 36,000 BTU/H) are available to meet your diversified air conditioning needs, and all capacities from 6,000 BTU/H to 36,000 BTU/H indoor units have a family design. From small rooms to large living rooms, it is possible to coordinate residences with a unified design.
MSZ-GL06/09/12/15NA MSY-GL09/12/15NA
MSZ/MSY-GL18NA
Compact Design
MSZ/MSY-GL24NA
MSZ/MSY-D30/36NA
MSZ-GL06/09/12/15NA MSY-GL09/12/15NA
Slim and compact indoor units provide enhanced, industry-leading performance for cooling and heating.
11-5/8in.
31-7/16in.
38
9-1/8in.
Quiet Operation The indoor unit noise level is as low as 19dB(A) for GL09/12 models, offering a peaceful inside environment.
Sound Level Human hearing limits (Extremely quiet)
Sound of rustling leaves
10dB(A)
Quiet passenger car interior (25mph)
Library interior
40dB(A) 60dB(A)
19dB(A)
Only
(for GL09/12 models)
Subway car interior
80dB(A) An in-company investigation
Powerful Operation (GL24, D30/36) Depending on the capacity, the unit will automatically adjust the fan speed and set temperature for 15 minutes. Rapid cooling and heating will make the room comfortable more quickly.
POWERFUL
Fan speed: Exclusive speed for POWERFUL mode. Horizontal Vane: Set position, or downward airflow position during AUTO setting.
Nano Platinum Filter (MSZ-GL06, MSZ/MSY-GL09/12/15/18/24) This filter generates stable antibacterial and deodorizing effects. The size of the three-dimensional surface has been increased as well, enlarging the filter capture area. These features give the Nano Platinum Filter better dust collection performance than conventional filters. The superior air cleaning effectiveness raises room comfort yet another level. ✽ It is okay to wash the filter with water (air cleaning effect is maintained)
3D surface (Waved surface)
Smart Set (MSZ-GL06, MSZ/MSY-GL09/12/15/18/24) Smart Set is a simplified setting function that recalls the preferred (pre-set) temperature by pressing a single button on the remote controller. Press the same button twice in repetition to immediately return to the previous temperature setting. Using this function contributes to comfortable, wastefree operation, realizing the most suitable air conditioning settings and saving on power consumption when, for example, leaving the room or going to bed.
70°F
Heating
65°F
Heating
39
Heat Caulking Fixing Method
MSZ/MSY-GL Model Indoor Unit
Outdoor Unit
MSZ-GL06/09/12/15NA MSY-GL09/12/15NA
Remote Controller
MUZ-GL09/12/15NA MUY-GL09/12/15NA
MUZ-GL18NA MUY-GL18NA * To confirm compatibility with the MXZ Model multi-zone system, refer to MXZ Model page.
MSZ-GL18NA MSY-GL18NA
Blue Fin
Nano Platinum
USNAP
Smart Set
GL18
Optional
Optional
Optional
Optional
Optional
Optional
T-STAT Optional
MSZ-GL06-18
Indoor Unit
MSY-GL09NA
MSY-GL12NA
MSY-GL15NA
MSY-GL18NA
MSY-GL24NA
MSY-D30NA
MSY-D36NA
Outdoor Unit
MUY-GL09NA
MUY-GL12NA
MUY-GL15NA
MUY-GL18NA
MUY-GL24NA
MUY-D30NA
MUY-D36NA
Cooling
Capacity
Rated 1
BTU/H
9,000
12,000
14,000
18,000
22,500
30,700
34,600
Capacity Range
Min-Max
BTU/H
3,600–12,200
1,500–13,600
3,100–18,200
5,800–22,000
8,200–31,400
9,800–30,600
9,800–34,600
Power Input
Rated 1
W
585
209
1,080
1,340
1,800
3,380
4,249
Moisture Removal
Pints/h
1.5
2.5
2.7
2.1
5.1
9.9
11.9
0.820
0.770
0.780
0.870
0.750
0.640
0.620
Sensible Heat Factor
Heating
Capacity at 47ºF
Rated
BTU/H
—
—
—
—
—
—
—
Capacity Range
Min-Max
BTU/H
—
—
—
—
—
—
—
Power Input at 47ºF Capacity at 17ºF Capacity at 5ºF
Efficiency
Rated
W
—
—
—
—
—
—
—
Rated
BTU/H
—
—
—
—
—
—
—
Max
BTU/H
—
—
—
—
—
—
—
Max
BTU/H
—
—
—
—
—
—
—
SEER
24.6
23.1
21.6
20.5
20.5
16.0
15.1
EER
15.4
13.0
13.0
13.4
12.5
9.1
8.2
HSPF
—
—
—
—
—
—
—
COP
—
—
—
—
—
—
—
ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi) Indoor Unit
Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Dry
CFM
Wet
CFM
Dry
CFM
Cooling
dB(A)
Heating
External Static Pressure Condensate Lift Mechanism
Yes
Yes
No
No
258–332–417– 522–646 232–299–375– 470–581
388–469–544– 628–738 347–420–487– 562–661
389–639–848– 887 350–576–763– 798
389–639–848– 887 350–576–763– 798
—
—
—
—
—
19–22–30–37–43 19–22–30–37–45 26–32–38–44–49 28–33–38–44–49 34–41–45–49–53
dB(A)
—
—
—
—
—
—
—
In. W.G.
—
—
—
—
—
—
—
—
—
—
—
—
—
—
11-5/8 [295]
11-5/8 [295]
11-5/8 [295]
12 [305]
12-13/16 [325]
14-3/8 [365]
14-3/8 [365]
W
In. [mm]
31-7/16 [798]
31-7/16 [798]
31-7/16 [798]
36-5/16 [923]
43-5/16 [1100]
46-1/16 [1170]
46-1/16 [1170]
D
In. [mm]
9-1/8 [232]
9-1/8 [232]
9-1/8 [232]
9-13/16 [250]
9-3/8 [238]
11-5/8 [295]
11-5/8 [295]
22 [10.0]
22 [10.0]
22 [10.0]
28 [13.0]
37 [17.0]
40 [18.0]
40 [18.0] 21.0
MCA
A
7.0
7.0
9.0
14.0
17.1
21.0
MOCP
A
15
15
15
15
20
25
25
In. [mm]
21-5/8 [550]
21-5/8 [550]
21-5/8 [550]
34-5/8 [880]
34-5/8 [880]
33-7/16 [850]
33-7/16 [850]
W
In. [mm]
31-1/2 [800]
31-1/2 [800]
31-1/2 [800]
33-1/16 [840]
33-1/16 [840]
33-1/16 [840]
33-1/16 [840]
D
In. [mm]
11-1/4 [286]
11-1/4 [286]
11-1/4 [286]
13 [330]
13 [330]
13 [330]
13 [330]
81 [36.7]
81 [36.7]
81 [36.7]
121 [55]
119 [54]
126 [57]
126 [57]
Weight
Sound Pressure Level
Diameter Piping
lbs [kg]
1229/—
1229/—
1243/—
1691/—
1769/—
1941/—
1941/—
Cooling
CFM dB(A)
48
49
49
54
55
55
56
Heating
dB(A)
—
—
—
—
—
—
—
Gas (O.D.)
In. [mm]
3/8 [9.52]
3/8 [9.52]
1/2 [12.7]
1/2 [12.7]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
Liquid (O.D)
In. [mm]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
Indoor Drain
In. [mm]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88] 100 [30]
Max. Length
ft [m]
65 [20]
65 [20]
65 [20]
100 [30]
100 [30]
100 [30]
Max. Height
ft [m]
40 [12]
40 [12]
40 [12]
50 [15]
50 [15]
50 [15]
50 [15]
Outdoor-Indoor 5
V, ph, Hz
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
Recommended Breaker Size A
15
15
15
15
20
25
25
R410A
R410A
R410A
R410A
R410A
R410A
R410A
ºF DB [ºC DB]
14.0 to 115.0 [-10.0 to 46.0]
14.0 to 115.0 [-10.0 to 46.0]
14.0 to 115.0 [-10.0 to 46.0]
14.0 to 115.0 [-10.0 to 46.0]
14.0 to 115.0 [-10.0 to 46.0]
14.0 to 115.0 [-10.0 to 46.0]
14.0 to 115.0 [-10.0 to 46.0]
ºF DB [ºC DB]
—
—
—
—
—
—
—
Refrigerant Type Guaranteed Cooling 6 Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
40
6
— 32–42–49–51
lbs [kg]
Air Flow Rate (Cooling/Heating)
5
— 32–42–49–51
Weight
Dimensions
Electrical
Yes 205–272–335– 420–533 170–237–300– 385–498
In. [mm]
H Outdoor Unit
Yes 145–170–237– 321–399 109–134–201– 286–364
Max Distance In. [mm] H
Dimensions
Yes 145–170–237– 321–399 109–134–201– 286–364
1
Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
Indoor units receive power from outdoor units through field-supplied interconnected wiring. Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
Heat Caulking Fixing Method
GL24
GL24
MSZ/MSY-GL Model MSZ/MSY-D Model Outdoor Unit
Indoor Unit
MSZ-GL24NA MSY-GL24NA
MSZ-D30/36NA MSY-D30/36NA
Blue Fin
MUZ-GL24NA MUY-GL24NA
Remote Controller
MUZ-D30/36NA MUY-D30/36NA * To confirm compatibility with the MXZ Model multi-zone system, refer to MXZ Model page.
Nano Platinum
USNAP
Smart Set
GL18
Optional
Optional
Optional
Optional
Optional
Optional
T-STAT Optional
MSZ-GL06-18
Indoor Unit
MSZ-GL06NA
Outdoor Unit
Cooling
MSZ-D30NA
MSZ-D36NA
MUZ-D30NA
MUZ-D36NA
BTU/H
—
9,000
12,000
14,000
18,000
22,400
30,600
33,200
BTU/H
—
3,600–12,200
1,500–13,600
3,100–18,200
5,800–22,000
8,200–31,400
9,800–30,700
9,800–33,200
Power Input
Rated 1
W
4,360
Moisture Removal
Pints/h
—
585
920
1,080
1,340
1,800
3,850
—
1.5
2.5
2.7
2.1
5.1
9.9
11.3
—
0.820
0.740
0.800
0.870
0.750
0.640
0.620
Capacity at 47ºF
Rated 2
BTU/H
—
10,900
14,400
18,000
21,600
27,600
32,600
35,200
Capacity Range
Min-Max
BTU/H
—
4,500–15,900
2,000–18,100
4,800–20,900
5,400–25,000
7,500–36,900
8,700–34,000
8,700–36,000
Power Input at 47ºF
Rated 2
W
—
720
1,100
1,600
1,680
2,340
3,360
3,840
Rated 3
BTU/H
—
6,700
9,200
12,200
13,800
16,000
19,500
21,800
Max
BTU/H
—
10,200
12,000
16,400
18,200
24,600
20,800
22,800
Max 4
BTU/H
—
8,170
9,790
13,680
14,904
19,320
—
—
—
24.6
23.1
21.6
20.5
20.5
14.5
14.5
EER
—
15.4
13.0
13.0
13.4
12.5
8.0
7.6
HSPF
—
12.8
12.5
11.7
11.2
10.0
8.2
8.2
COP
—
4.44
3.84
3.3
3.77
3.46
2.84
2.69
ENERGY STAR® Certified
—
Yes
Yes
Yes
Yes
Yes
No
No
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Dry
CFM
Wet
CFM
Dry
CFM
Cooling
dB(A)
Heating
External Static Pressure
dB(A)
145–170–237– 145–170–237– 145–170–237– 205–272–335– 258–332–417– 388–469–544– 389–639–848– 389–639–848– 321–399 321–399 321–399 420–533 522–646 628–738 887 887 109–134–201– 109–134–201– 109–134–201– 170–237–300– 232–299–375– 347–420–487– 350–576–763– 350–576–763– 286–364 286–364 286–364 385–498 470–581 562–661 798 798 145–170–237– 145–170–237– 145–170–237– 205–247–304– 297–385–469– 388–469–544– 445–639–848– 445–639–686– 321–406 321–406 321–406 367–463 565–646 628–738 887 887 19–22–30– 19–22–30– 19–22–30– 26–32–38– 28–33–38– 34–41–45– 32–42–49–51 32–42–49–51 37–43 37–43 37–45 44–49 44–49 49–53 19–22–30– 19–22–30– 19–22–30– 26–30–35– 28–33–38– 32–41–45– 34–42–49–50 34–42–49–50 37–43 37–43 37–43 40–46 43–48 49–52
In. W.G.
—
—
—
—
—
—
—
—
Condensate Lift Mechanism
Max Distance In. [mm]
—
—
—
—
—
—
—
—
H
In. [mm]
11-5/8 [295]
11-5/8 [295]
11-5/8 [295]
11-5/8 [295]
12 [305]
12-13/16 [325]
14-3/8 [365]
14-3/8 [365]
Dimensions
W
In. [mm]
31-7/16 [798]
31-7/16 [798]
31-7/16 [798]
31-7/16 [798]
36-5/16 [923]
43-5/16 [1100]
46-1/16 [1170]
46-1/16 [1170]
D
In. [mm]
9-1/8 [232]
9-1/8 [232]
9-1/8 [232]
9-1/8 [232]
9-13/16 [250]
9-3/8 [238]
11-5/8 [295]
11-5/8 [295]
Weight
lbs [kg]
22 [10.0]
22 [10.0]
22 [10.0]
22 [10.0]
28 [13.0]
37 [17.0]
40 [18.0]
40 [18.0]
MCA
A
—
9.0
9.0
10.0
14.0
17.0
21.0
21.0
MOCP
A
—
15
15
15
15
20
25
25
—
21-5/8 [550]
21-5/9 [550]
21-5/10 [550]
34-5/8 [880]
34-5/8 [880]
33-7/16 [850]
33-7/16 [850]
H Dimensions
In. [mm]
W
In. [mm]
—
31-1/2 [800]
31-1/2 [800]
31-1/4 [800]
33-1/16 [840]
33-1/16 [840]
33-1/16 [840]
33-1/16 [840]
D
In. [mm]
—
11-1/4 [285]
11-1/5 [285]
11-1/6 [285]
13 [330]
13 [330]
13 [330]
13 [330]
Weight
lbs [kg]
—
81 [37]
81 [37]
81 [37]
121 [55]
119 [54]
141 [64]
141 [64]
Air Flow Rate (Cooling/Heating)
CFM
—
1229/1172
1229/1172
1243/1129
1691/1691
1769/1701
1941/1941
1941/1941
Sound Pressure Level
Diameter Piping
Electrical
MSZ-GL24NA MUZ-GL24NA
Min-Max
SEER
Outdoor Unit
MSZ-GL18NA MUZ-GL18NA
Rated 1
Capacity at 17ºF
Indoor Unit
MSZ-GL15NA MUZ-GL15NA
Capacity Range
Capacity at 5ºF
Efficiency
MSZ-GL12NA MUZ-GL12NA
Capacity
Sensible Heat Factor
Heating
MSZ-GL09NA MUZ-GL09NA
Cooling
dB(A)
—
48
49
49
54
55
55
56
Heating
dB(A)
—
50
51
51
55
55
57
56 5/8 [15.88]
Gas (O.D.)
In. [mm]
—
3/8 [9.52]
3/8 [9.52]
1/2 [12.7]
1/2 [12.7]
5/8 [15.88]
5/8 [15.88]
Liquid (O.D)
In. [mm]
—
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
Indoor Drain
In. [mm]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88] 100 [30]
Max. Length
ft [m]
—
65 [20]
65 [20]
65 [20]
100 [30]
100 [30]
100 [30]
Max. Height
ft [m]
—
40 [12]
40 [12]
40 [12]
50 [15]
50 [15]
50 [15]
50 [15]
Outdoor-Indoor 5
V, ph, Hz
—
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
Recommended Breaker Size A
Refrigerant Type Cooling 6 Guaranteed Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
—
15
15
15
15
20
25
25
—
R410A
R410A
R410A
R410A
R410A
R410A
R410A
14.0 to 115.0 [-10.0 to 46.0] -4.0 to 75.0 [-20.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -4.0 to 75.0 [-20.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -4.0 to 75.0 [-20.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -4.0 to 75.0 [-20.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -4.0 to 75.0 [-20.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -4.0 to -75.0 [-20.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -4.0 to -75.0 [-20.0 to 24.0]
ºF DB [ºC DB]
—
ºF DB [ºC DB]
—
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 1 2 3
41
MSZ-HM Model Compact, high-performance indoor and outdoor units and advanced inverter technologies provide superior energy savings and comfort in all rooms.
MSZ-HM09/12/15NA
MSZ-HM18/24NA
Stylish Design with Flat Panel Front
Quiet Operation
A stylish flat panel design is employed for the front of the indoor unit. The simple look matches room aesthetics.
Quiet, relaxing space is within reach. Operational noise is a low 22dB(A) (09/12 classes). Operation is so silent you might even forget the air conditioner is on. Sound Level Human hearing limits (Extremely quiet)
Sound of rustling leaves
10dB(A)
Library interior
Quiet passenger car interior (25mph)
40dB(A) 60dB(A)
22dB(A)*
Subway car interior
80dB(A)
Only
*MSZ-HM09/12NA
An in-company investigation
Econo Cool Energy-Saving Feature Econo Cool is an intelligent temperature control feature that adjusts the amount of air directed towards the body based on the air-outlet temperature. The setting temperature can be raised by as much as 4° F without any loss in comfort, thereby realizing a 20% gain in energy efficiency. (Function only available during manual cooling operation.) Conventional
Econo Cool
Ambient Temperature
95° F
95° F
Set Temperature
77° F
81° F
Perceived Temperature
86° F
85° F
Econo Cool Mode A comfortable room environment is maintained even when setting the temperature 4° F higher than the conventional cooling mode. Econo Cool on
Conventional cooling mode
Temperature distribution (° F) 58 61 64 68 72 75 79 82
12-hour Timer
Air Filter
Allows for one ON/OFF cycle during a 12-hour period.
This filter can remove dust particles from the air.
Blue Fin Heat Exchanger Anti-allergy Enzyme Filter*
(*Optional)
This filter works to trap allergens such as molds and bacteria and decompose them using enzymes retained in the filter.
42
Anti-corrosion treatment is done to the heat exchanger of the outdoor units. This coating prevents the corrosion of the aluminum fins caused by salt in the air especially in coastal areas. (Corrosion of the heat exchanger will effect the efficiency and performance of the air conditioner.)
Heat Caulking Fixing Method
MSZ-HM Model Indoor Unit
Outdoor Unit
MSZ-HM09/12/15NA
Remote Controller MUZ-HM09/12/15/18NA
MUZ-HM24NA
MSZ-HM18/24NA
Blue Fin
Optional Controller Holder: U01A01083
Air Filter Optional
12 hour
Indoor Unit
MSZ-HM09NA
MSZ-HM12NA
MSZ-HM15NA
MSZ-HM18NA
MSZ-HM24NA
Outdoor Unit
MUZ-HM09NA
MUZ-HM12NA
MUZ-HM15NA
MUZ-HM18NA
MUZ-HM24NA
Cooling
Capacity
Rated 1
BTU/H
9,000
12,000
14,000
17,200
22,500
Capacity Range
Min-Max
BTU/H
3,800–10,000
3,800–12,200
3,100–16,000
5,800–18,000
5,800–22,500
Power Input
Rated 1
W
750
1,210
1,170
1,640
2,630
Moisture Removal
Pints/h
1.5
2.5
2.7
2.1
2.3
0.820
0.770
0.780
0.860
0.890
Sensible Heat Factor
Heating
Capacity at 47ºF
Rated 2
BTU/H
10,900
12,200
18,000
18,000
26,000
Capacity Range
Min-Max
BTU/H
4,500–11,800
4,500–14,500
4,800–18,500
5,400–20,900
5,400–26,000
Power Input at 47ºF
Rated 2
W
900
990
1,600
1,590
2,500
Rated 3
BTU/H
6,700
7,600
11,500
11,500
18,500
Max
BTU/H
7,200
900
14,000
15,000
18,500
Max 4
BTU/H
5,990
9,000
12,240
12,780
15,600
SEER
18.0
18.0
18.0
18.0
18.0
EER
12.0
9.9
12.0
10.5
8.6
HSPF
10
10
10
10
10
COP
3.55
3.61
3.3
3.32
3.05
Capacity at 17ºF Capacity at 5ºF
Efficiency
ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi)
No
No
No
No
170–237–321–399
272–335–420–533
328–431–530–625
353–431–530–702
CFM
134–201–286–364
134–201–286–364
237–300–385–498
295–388–477–562
318–388–477–632
CFM
170–237–321–406
170–237–321–406
247–304–367–463
307–431–530–625
346–448–579–702
Cooling
dB(A)
22–30–37–43
22–30–37–45
32–38–44–49
30–37–42–47
33–38–44–50
Heating
dB(A)
22–30–37–43
22–30–37–43
30–35–40–46
30–37–42–47
32–38–44–50
In. W.G.
—
—
—
—
—
Condensate Lift Mechanism
Max Distance In. [mm]
—
—
—
—
—
H
In. [mm]
11-5/8 [295]
11-5/8 [295]
11-5/8 [295]
12 [305]
12 [305]
Dimensions
W
In. [mm]
31-7/16 [798]
31-7/16 [798]
31-7/16 [798]
36-5/16 [923]
36-5/16 [923]
D
In. [mm]
9-1/8 [232]
9-1/8 [232]
9-1/8 [232]
9-13/16 [250]
9-13/16 [250]
Weight
lbs [kg]
22 [10.0]
22 [10.0]
22 [10.0]
28 [13.0]
28 [13.0]
MCA
A
9.0
9.0
10.0
10.0
14.0
MOCP
A
15
15
15
15
15
In. [mm]
21-5/8 [550]
21-5/8 [550]
21-5/8 [550]
21-5/8 [550]
34-5/8 [880]
W
In. [mm]
31-1/2 [800]
31-1/2 [800]
31-1/2 [800]
31-1/2 [800]
33-1/16 [840]
D
In. [mm]
11-1/4 [286]
11-1/4 [286]
11-1/4 [286]
11-1/4 [286]
13 [330]
73 [33.1]
73 [33.1]
81 [36.7]
81 [36.7]
121 [55] 1691/1691
External Static Pressure
H Dimensions Weight Air Flow Rate (Cooling/Heating) Sound Pressure Level
Diameter Piping
Electrical
No 170–237–321–399
Wet
Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Outdoor Unit
CFM
Dry
Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi)
Indoor Unit
Dry
lbs [kg]
1151/1225
1151/1225
1243/1229
1243/1229
Cooling
CFM dB(A)
46
49
49
50
54
Heating
dB(A)
50
51
51
51
55 5/8 [15.88]
Gas (O.D.)
In. [mm]
3/8 [9.52]
3/8 [9.52]
1/2 [12.7]
1/2 [12.7]
Liquid (O.D)
In. [mm]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
3/8 [9.52]
Indoor Drain
In. [mm]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88] 100 [30]
Max. Length
ft [m]
65 [20]
65 [20]
65 [20]
65 [20]
Max. Height
ft [m]
40 [12]
40 [12]
40 [12]
40 [12]
50 [15]
Outdoor-Indoor 5
V, ph, Hz
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
Recommended Breaker Size A
Refrigerant Type Cooling 6 Guaranteed Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
ºF DB [ºC DB] ºF DB [ºC DB]
15
15
15
15
15
R410A
R410A
R410A
R410A
R410A
14.0 to 115.0 [-10.0 to 46.0] -4.0 to 75.0 [-20.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -4.0 to 75.0 [-20.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -4.0 to 75.0 [-20.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -4.0 to 75.0 [-20.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -4.0 to 75.0 [-20.0 to 24.0]
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 1 2 3
43
JP Model
MSZ-JP09/12WA
The 115 volt single-zone MSZ-JP Model is ideal for homes or businesses with electrical service restrictions.
Stylish Design with Flat Panel Front
Quiet Operation
A stylish flat panel design is employed for the front of the indoor unit. The simple look matches room aesthetics.
Quiet, relaxing space is within reach. Operational noise is a low 22dB(A) (09/12 classes). Operation is so silent you might even forget the air conditioner is on. Sound Level Human hearing limits (Extremely quiet)
Sound of rustling leaves
10dB(A)
Library interior
Quiet passenger car interior (25mph)
40dB(A) 60dB(A)
22dB(A)*
Subway car interior
80dB(A)
Only
*MSZ-JP09/12WA
An in-company investigation
Econo Cool Energy-Saving Feature Econo Cool is an intelligent temperature control feature that adjusts the amount of air directed towards the body based on the air-outlet temperature. The setting temperature can be raised by as much as 4° F without any loss in comfort, thereby realizing a 20% gain in energy efficiency. (Function only available during manual cooling operation.) Conventional
Econo Cool
Ambient Temperature
95° F
95° F
Set Temperature
77° F
81° F
Perceived Temperature
86° F
85° F
Econo Cool Mode A comfortable room environment is maintained even when setting the temperature 4° F higher than the conventional cooling mode. Econo Cool on
Conventional cooling mode
Temperature distribution (° F) 58 61 64 68 72 75 79 82
12-hour Timer
Air Filter
Allows for one ON/OFF cycle during a 12-hour period.
This filter can remove dust particles from the air.
Blue Fin Heat Exchanger Anti-allergy Enzyme Filter*
(*Optional)
This filter works to trap allergens such as molds and bacteria and decompose them using enzymes retained in the filter.
44
Anti-corrosion treatment is done to the heat exchanger of the outdoor units. This coating prevents the corrosion of the aluminum fins caused by salt in the air especially in coastal areas. (Corrosion of the heat exchanger will effect the efficiency and performance of the air conditioner.)
Heat Caulking Fixing Method
MSZ-JP Model Outdoor Unit
Indoor Unit
MUZ-JP09/12WA
MSZ-JP09/12WA
Blue Fin
Remote Controller
Air Filter Optional
12 hour
Indoor Unit
MSZ-JP09WA
MSZ-JP12WA
Outdoor Unit
MUZ-JP09WA
MUZ-JP12WA
Cooling
Capacity
Rated 1
BTU/H
9,000
12,000
Capacity Range
Min-Max
BTU/H
3,800–10,000
3,800–12,000
Power Input
Rated 1
W
750
1,210
Moisture Removal
Pints/h
Sensible Heat Factor
Heating
Rated 2
BTU/H
10,900
12,200
Min-Max
BTU/H
4,500–11,800
4,500–14,500
Power Input at 47ºF
Rated 2
W
900
900
Rated 3
BTU/H
6,700
7,600
Max
BTU/H
7,200
9,000
Max 4
BTU/H
5,990
7,440
SEER
17.0
17.0
EER
12.0
9.9
HSPF
9
9
COP
3.55
3.61
ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi)
Dry
No
No
170–237–321–399
170–237–321–399
Wet
CFM
134–201–286–364
134–201–286–364
CFM
170–237–321–406
170–237–321–406
Cooling
dB(A)
22–30–37–43
22–30–37–43
Heating
dB(A)
22–30–37–43
22–30–37–43
In. W.G.
—
—
Condensate Lift Mechanism
Max Distance In. [mm]
—
—
H
In. [mm]
11-5/8 [295]
11-5/8 [295]
Dimensions
W
In. [mm]
31-7/16 [798]
31-7/16 [798]
D
In. [mm]
9-1/8 [232]
9-1/8 [232]
Weight
lbs [kg]
22 [10]
22 [10]
MCA
A
12.0
14.0
MOCP
A
15
15
In. [mm]
21-5/8 [550]
21-5/8 [550]
W
In. [mm]
31-1/2 [800]
31-1/2 [800]
D
In. [mm]
11-1/4 [285]
11-1/4 [285]
Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) External Static Pressure
H Dimensions Weight
lbs [kg]
Air Flow Rate (Cooling/Heating)
CFM
Sound Pressure Level
Diameter Piping
Electrical
CFM
Dry
Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi)
Outdoor Unit
0.770
Capacity Range
Capacity at 17ºF
Indoor Unit
2.5
0.820
Capacity at 47ºF
Capacity at 5ºF
Efficiency
1.5
81 [37]
81 [37]
1105/1225
1105/1225
Cooling
dB(A)
46
49
Heating
dB(A)
46
50
Gas (O.D.)
In. [mm]
3/8 [9.52]
3/8 [9.52]
Liquid (O.D)
In. [mm]
1/4 [6.35]
1/4 [6.35]
Indoor Drain
In. [mm]
5/8 [15.88]
5/8 [15.88]
Max. Length
ft [m]
40 [12]
40 [12]
Max. Height
ft [m]
65 [20]
65 [20]
Outdoor-Indoor 5
V, ph, Hz
115, 1, 60
115, 1, 60
Recommended Breaker Size A
Refrigerant Type Cooling 6 Guaranteed Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
ºF DB [ºC DB] ºF DB [ºC DB]
15
15
R410A
R410A
14.0 to 115.0 [-10.0 to 46.0] -4.0 to 75.0 [-20.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -4.0 to 75.0 [-20.0 to 24.0]
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 1 2 3
45
WR Model
MSZ-WR09/12NA
The WR Model is a basic 16 SEER INVERTER-driven heat pump.
MSZ-WR18/24NA
Stylish Design with Flat Panel Front
Quiet Operation
A stylish flat panel design is employed for the front of the indoor unit. The simple look matches room aesthetics.
Quiet, relaxing space is within reach. Operational noise is a low 22dB(A) (09/12 classes). Operation is so silent you might even forget the air conditioner is on. Sound Level Human hearing limits (Extremely quiet)
Sound of rustling leaves
10dB(A)
Library interior
Quiet passenger car interior (25mph)
40dB(A) 60dB(A)
22dB(A)*
Subway car interior
80dB(A)
Only
*MSZ-WR09/12NA
An in-company investigation
Econo Cool Energy-Saving Feature Econo Cool is an intelligent temperature control feature that adjusts the amount of air directed towards the body based on the air-outlet temperature. The setting temperature can be raised by as much as 4° F without any loss in comfort, thereby realizing a 20% gain in energy efficiency. (Function only available during manual cooling operation.) Conventional
Econo Cool
Ambient Temperature
95° F
95° F
Set Temperature
77° F
81° F
Perceived Temperature
86° F
85° F
Econo Cool Mode A comfortable room environment is maintained even when setting the temperature 4° F higher than the conventional cooling mode. Econo Cool on
Conventional cooling mode
Temperature distribution (° F) 58 61 64 68 72 75 79 82
12-hour Timer
Air Filter
Allows for one ON/OFF cycle during a 12-hour period.
This filter can remove dust particles from the air.
Blue Fin Heat Exchanger Anti-allergy Enzyme Filter*
(*Optional)
This filter works to trap allergens such as molds and bacteria and decompose them using enzymes retained in the filter.
46
Anti-corrosion treatment is done to the heat exchanger of the outdoor units. This coating prevents the corrosion of the aluminum fins caused by salt in the air especially in coastal areas. (Corrosion of the heat exchanger will effect the efficiency and performance of the air conditioner.)
Heat Caulking Fixing Method
MSZ-WR Model Indoor Unit
MSZ-WR09/12NA
Outdoor Unit
Remote Controller MUZ-WR09/12NA
MUZ-WR18/24NA
MSZ-WR18/24NA
Blue Fin
Optional Controller Holder: U01A01083
Air Filter Optional
12 hour
Indoor Unit
MSZ-WR09NA
MSZ-WR12NA
MSZ-WR18NA
MSZ-WR24NA
Outdoor Unit
MUZ-WR09NA
MUZ-WR12NA
MUZ-WR18NA
MUZ-WR24NA
Cooling
Capacity
Rated 1
BTU/H
9,000
12,000
17,200
22,500
Capacity Range
Min-Max
BTU/H
3,800–10,000
3,800–12,200
5,800–18,000
5,800–22,500
Power Input
Rated 1
W
820
1,330
1,720
2,810
Moisture Removal
Pints/h
1.5
2.5
2.1
2.3
0.820
0.770
0.860
0.890
Sensible Heat Factor
Heating
Capacity at 47ºF
Rated 2
BTU/H
10,900
12,200
18,000
26,000
Capacity Range
Min-Max
BTU/H
4,500–11,800
4,500–14,500
5,400–20,900
5,400–26,000
Power Input at 47ºF Capacity at 17ºF
W
980
1,090
1,670
2,680
BTU/H
6,700
7,600
11,500
18,500
Max
BTU/H
7,200
9,000
15,000
18,500
Max 4
BTU/H
5,990
7,440
12,780
15,600
SEER
16.0
16.0
16.0
16.0
EER
11.0
9.0
10.0
8.0
HSPF
8.5
8.5
8.5
8.5
COP
3.25
3.28
3.16
2.84
Capacity at 5ºF
Efficiency
Rated 2 Rated 3
ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Indoor Unit
Dimensions
No
No
170–237–321–399
170–237–321–399
328–431–530–625
353–431–530–702
Wet
CFM
134–201–286–364
134–201–286–364
295–388–477–562
318–388–477–632
Dry
CFM
170–237–321–406
170–237–321–406
307–431–530–625
346–448–579–702
Cooling
dB(A)
22–30–37–43
22–30–37–45
30–37–42–47
33–38–44–50
Heating
dB(A)
22–30–37–43
22–30–37–43
30–37–42–47
32–38–44–50
In. W.G.
—
—
—
—
Max Distance In. [mm]
—
—
—
—
H
In. [mm]
11-5/8 [295]
11-5/8 [295]
12 [305]
12 [305]
W
In. [mm]
31-7/16 [798]
31-7/16 [798]
36-5/16 [923]
36-5/16 [923]
D
In. [mm]
9-1/8 [232]
9-1/8 [232]
9-13/16 [250]
9-13/16 [250]
22 [10]
22 [10]
28 [13]
28 [13] 14.0
Weight
lbs [kg]
MCA
A
9.0
9.0
10.0
MOCP
A
15
15
15
15
Dimensions
H
In. [mm]
21-5/8 [550]
21-5/8 [550]
34-5/8 [880]
34-5/8 [880]
W
In. [mm]
31-1/2 [800]
31-1/2 [800]
33-1/16 [840]
31-1/16 [840]
D
In. [mm]
11-1/4 [286]
11-1/4 [286]
13 [330]
13 [330]
73 [33.1]
73 [33.1]
81 [36.7]
121 [54.9]
Weight
lbs [kg]
Air Flow Rate (Cooling/Heating)
CFM
Sound Pressure Level
Diameter Piping
Electrical
No
CFM
External Static Pressure Condensate Lift Mechanism
Outdoor Unit
No Dry
1151/1225
1151/1225
1243/1229
1691/1691
Cooling
dB(A)
48
51
53
57
Heating
dB(A)
50
51
51
55
Gas (O.D.)
In. [mm]
3/8 [9.52]
3/8 [9.52]
1/2 [12.7]
5/8 [15.88]
Liquid (O.D)
In. [mm]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
3/8 [9.52]
Indoor Drain
In. [mm]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
Max. Length
ft [m]
40 [12]
40 [12]
40 [12]
50 [15]
Max. Height
ft [m]
65 [20]
65 [20]
65 [20]
100 [30]
Outdoor-Indoor 5
V, ph, Hz
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
15
15
15
15
R410A
R410A
R410A
R410A
32.0 to 115.0 [-10.0 to 46.0] 5.0 to 75.0 [-20.0 to 24.0]
32.0 to 115.0 [-10.0 to 46.0] 5.0 to 75.0 [-20.0 to 24.0]
32.0 to 115.0 [-10.0 to 46.0] 5.0 to 75.0 [-20.0 to 24.0]
32.0 to 115.0 [-10.0 to 46.0] 5.0 to 75.0 [-20.0 to 24.0]
Recommended Breaker Size A
Refrigerant Type Cooling 6 Guaranteed Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
ºF DB [ºC DB] ºF DB [ºC DB]
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 1 2 3
47
MFZ-KJ Model
MFZ-KJ09/12/15/18NA
High capacity, energy savings and a design that harmonizes with living spaces raise the value of your room to the next level.
Simple Flat Design Uneven surfaces have been smoothed to provide a simple design with linear beauty, harmonized with all types of interiors. Unique configuration realizing a flat, stylish look
Two-block structure to accommodate various installation patterns
Images of installed unit Standard
23-5/8 in.
Simple, symmetrical design
Ingenious structure realizing low-profile air inlet
Removable base section
29-17/32 in.
Semi-inbuilt
Base can be removed to accentuate the stylish main body
5-23/32 in. 8-15/32 in.
Multi-flow Vane Three uniquely shaped vanes control the airflow and allow the freedom to customize comfort according to preferences. When heating
When cooling Air currents can be controlled freely
Rapid heating Warm air is blown out in a downward direction and then sucked back into the unit to quickly raise the temperature of the air being blown out. *The downward airflow is also possible as well as heating.
Air Distribution (MFZ-KJ15NA) (sectional view)
10 min later
Outside Temp: 5째 F Set Temp: 73째 F Fan mode: auto
30 min later
Even distribution of warm air throughout the room 60 min later
80째 F
41째 F
48
MFZ-KJ Model Outdoor Unit
Indoor Unit
Remote Controller
MUFZ-KJ09/12NAHZ
* To confirm compatibility with the MXZ Model multi-zone system, refer to MXZ Model page.
MFZ-KJ09/12/15/18NA MUFZ-KJ15/18NAHZ
Blue Fin
Nano Platinum
POWERFUL MODE
Sleep Optional
Optional
USNAP Optional
T-STAT Optional
Optional
Optional
Indoor Unit Outdoor Unit
Cooling
BTU/H
9,000
12,000
15,000
17,000
BTU/H
2,300–14,000
2,300–15,000
5,300–19,000
5,300–22,500
Power Input
Rated 1
W
570
890
1,120
1,350
Moisture Removal
Pints/h
1.4
2.7
3.9
4.4
0.790
0.700
0.660
0.650
Capacity at 47ºF
Rated 2
BTU/H
11,000
13,000
18,000
21,000
Capacity Range
Min-Max
BTU/H
2,900–19,000
2,900–22,800
5,700–25,000
5,700–29,000
Power Input at 47ºF
Rated 2
W
750
900
1,410
1,730
Rated 3
BTU/H
7,500
8,800
12,000
12,800
Max
BTU/H
13,400
14,800
20,500
23,000
Max 4
BTU/H
11,000
13,000
18,000
21,000
SEER
28.2
25.5
21.8
21.0
EER
15.8
13.6
13.5
12.6
HSPF
13
12
11.6
11.3
COP
4.3
4.2
3.7
3.5
ENERGY STAR® Certified
Yes
Yes
Yes
Yes
Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Dry
CFM
138–198–272–360–417
138–198–272–360–417
198–254–311–392–431
198–254–328–420–491
Wet
CFM
117–168–231–306–354
117–168–231–306–354
168–216–264–333–366
168–216–279–357–417
Dry
CFM
138–191–254–328–417
138–191–254–328–417
212–268–328–399–470
212–268–328–399–470
Cooling
dB(A)
21–27–34–41–46
21–27–34–41–46
28–33–38–43–47
28–33–39–45–50
Heating
dB(A)
21–27–34–40–46
21–27–34–40–46
29–35–40–45–49
29–35–40–45–49
In. W.G.
—
—
—
—
Max Distance In. [mm]
—
—
—
—
External Static Pressure Condensate Lift Mechanism Dimensions
H
In. [mm]
23-5/8 [600]
23-5/8 [600]
23-5/8 [600]
23-5/8 [600]
W
In. [mm]
29-17/32 [750]
29-17/32 [750]
29-17/32 [750]
29-17/32 [750]
D
In. [mm]
8-15/32 [215]
8-15/32 [215]
8-15/32 [215]
8-15/32 [215]
33 [15.0]
33 [15.0]
33 [15.0]
33 [15.0] 16.0
Weight
lbs [kg]
MCA
A
11.0
11.0
16.0
MOCP
A
15
15
20
20
Dimensions
H
In. [mm]
21-5/8 [550]
21-5/8 [550]
21-5/8 [880]
21-5/8 [880]
W
In. [mm]
31-1/2 [800]
31-1/2 [800]
31-1/2 [840]
31-1/2 [840]
D
In. [mm]
11-1/4 [285]
11-1/4 [285]
11-1/4 [330]
11-1/4 [330]
83 [38]
83 [38]
124 [56]
124 [56]
1074/1202
1074/1202
1653/1730
1653/1730 51
Weight
lbs [kg]
Air Flow Rate (Cooling/Heating)
CFM
Sound Pressure Level
Diameter Piping
Electrical
MFZ-KJ18NA MUFZ-KJ18NAHZ
Rated 1
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi)
Outdoor Unit
MFZ-KJ15NA MUFZ-KJ15NAHZ
Min-Max
Capacity at 5ºF
Indoor Unit
MFZ-KJ12NA MUFZ-KJ12NAHZ
Capacity
Capacity at 17ºF
Efficiency
MFZ-KJ09NA MUFZ-KJ09NAHZ Capacity Range
Sensible Heat Factor
Heating
Optional
Optional
Cooling
dB(A)
48
48
51
Heating
dB(A)
50
50
55
55
Gas (O.D.)
In. [mm]
3/8 [9.52]
3/8 [9.52]
1/2 [12.7]
1/2 [12.7]
Liquid (O.D)
In. [mm]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
Indoor Drain
In. [mm]
19/32 O.D [15]
19/32 O.D [15]
19/32 O.D [15]
19/32 O.D [15] 100 [30]
Max. Length
ft [m]
65 [20]
65 [20]
100 [30]
Max. Height
ft [m]
40 [12]
40 [12]
50 [15]
50 [15]
Outdoor-Indoor 5
V, ph, Hz
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
Recommended Breaker Size A
Refrigerant Type Cooling 6 Guaranteed Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
ºF DB [ºC DB] ºF DB [ºC DB]
15
15
20
20
R410A
R410A
R410A
R410A
14.0 to 115.0 [-10.0 to 46.0] -13.0 to 75.0 [-25.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -13.0 to 75.0 [-25.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -13.0 to 75.0 [-25.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -13.0 to 75.0 [-25.0 to 24.0]
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 1 2 3
49
SUZ Model
SUZ heat pump and hyper-heating outdoor units achieve high energy-saving performance as well as heating capacity and all the combinations are ENERGY STAR® qualified. For an attractive and optimum use of indoor space, you can choose the indoor unit that best matches your needs. SUZ-KF09/12/15/18NAHZ
SUZ-KA09/12/15NA 2
SLZ
MLZ
SUZ-KA09/12/15/18NAHZ
SUZ-KA18/24/30/36NA 2
PEAD
SEZ
• Available capacities in KBTU/H: 9, 12, 15, 18, 24, 30, 36 • Single-zone outdoor unit matches multiple indoor unit options • Heat Pump or Hyper-Heating INVERTER®
SVZ
SUZ Compatibility Outdoor Unit Capacity KBTU/H
50
9
12
15
HP
18
HP
24
HP
HP
HP
•
•
•
•
•
•
•
•
•
•
•
Type
HP
SLZ-KF
2′ x 2′ cassette
•
•
•
•
•
•
•
•
SEZ-KD
Low static ducted
•
•
•
•
•
•
•
•
PEAD
Mid static ducted
•
•
•
•
•
•
•
SVZ
Multi-position Air Handler
•
•
MLZ-KP
EZ FIT™ Recessed Ceiling Cassette
•
•
•
36
HP
Model
•
30
Hyper-Heating Inverter The H2i® models provide heating even when it's -13° F (-25° C) outdoor ambient, producing up to 100% heating capacity at 5° F (-15° C). These units offer year-round comfort even in extreme climates.
Heating Performance at Low Temperatures
Heating capacity (%)
Operation guaranteed at –13° F, 100% heating capacity at 5° F
SUZ-KA09NAHZ
H2i SUZ Standard Heat Pump 100% heating capacity as low as 5° F (-15° C)
Heating operation down to -13° F (-25° C)
-4° F (-20° C)
SLZ
SEZ
PEAD
MLZ
COP at
SLZ
SEZ
PEAD
SVZ
MLZ
47° F
3.90
2.80
3.80
4.10
47° F
3.40
3.90
3.90
3.80
3.80
17° F
2.56
2.20
2.56
2.76
17° F
2.38
2.56
2.72
2.61
2.54
5° F
1.34
1.59
1.67
1.67
5° F
1.83
2.19
2.09
1.69
1.57
SUZ-KA15NAHZ
100%
-13° F (-25° C)
SUZ-KA12NAHZ
COP at
5° F (-15° C)
19° F (-7° C)
32° F (0° C)
SUZ-KA18NAHZ
COP at
SLZ
SEZ
PEAD
COP at
SLZ
SEZ
PEAD
SVZ
MLZ
47° F
2.60
2.70
3.00
47° F
2.70
3.40
3.30
3.30
3.00
17° F
1.91
2.15
2.29
17° F
2.20
2.52
2.49
2.32
2.42
5° F
1.84
1.88
1.81
5° F
1.44
1.75
1.66
1.75
1.39
Outdoor Air Temperature
Operation Guaranteed at Outside Temperature of –13° F (–25° C)
Built-in Base Heater The base heater restricts lowered capacity and operation shutdowns caused by the drain water freezing. This supports stable operation in low-temperature environments.
Frozen drain
Drain does not freeze
Without base heater
Compact and Powerful Compressor A special manufacturing technology, Heat Caulking Fixing Method, has been introduced to reduce compressor size while maintaining a high compressor output. This technology enables the installation of a powerful compressor in compact outdoor units. As a result, excellent heating performance is achieved when operating in cold outdoor environments.
With base heater
Compressor using conventional method (Arc spot-welded method)
TNB220F
Outer layer must be thick enough to hold the cylinder.
Compressor using Heat Caulking Fixing Method Downsized by 13%
SNB220F
Compressor size reduced while maintaining same cylinder inner diameter.
51
MLZ Model
MLZ-KP09/12/18NA
Introducing EZ FIT™ ceiling cassette with streamlined interior dimensions and a sharp, sleek appearance.
Slim Design Industry leading slim body realized a simple design with linear beauty.
Ceiling Mounted
Slim Body
Installing the ceiling-mounted EZ FIT Model unit in a room creates a more spacious feel that enhances room comfort. This overhead format is also an excellent solution when lighting equipment is installed at the center of the room and fixtures such as book shelves are mounted on wall surfaces.
The new units are designed with a slim body (only 7-5/16"), ensuring easy installation even when low ceiling cavities limit installation space. The need for ceiling cavity service space is also eliminated, further reducing the dimensions required for installation.
7-5/16"
Set Airflow According to Ceiling Height Dual-level airflow selection is engineered to accommodate specific ceiling heights. This is a key feature for adjusting airflow effectively when it is either too strong or too weak due to being mismatched with the height of the ceiling.
52
09
12
18
Standard
7-7/8 ft.
7-7/8 ft.
7-7/8 ft.
High ceiling
8-7/8 ft.
8-7/8 ft.
8-7/8 ft.
Auto Vane Control Outlet vanes can be moved left and right, and up and down using the remote controller. This improved airflow control feature solves the problem of drafts.
Up and Down
Left and Right ✽ Only available when Econo Cool is set.
Built-in Weekly Timer Function
Easily set desired temperatures and operation ON/OFF times to match lifestyle patterns. Reduce wasted energy consumption by using the timer to prevent forgetting to turn off the unit and eliminate temperature setting adjustments. Example Operation Pattern (Winter/Heating mode)
AM
Mon.
Tues.
Wed.
Thurs.
Fri.
Sat.
Sun.
ON 68°F
ON 68°F
ON 68°F
ON 68°F
ON 68°F
ON 68°F
ON 68°F
ON 64°F
ON 64°F
Automatically changes to high-power operation at wake-up time
AM AM AM
OFF
OFF
OFF
OFF
OFF
Midday is warmer, so the temperature is set lower
Automatically turned off during work hours
PM PM PM
ON 72°F
PM
ON 72°F
ON 72°F
ON 72°F
ON 72°F
ON 72°F
ON 72°F
Automatically raises temperature setting to match time when outside-air temperature is low
Automatically turns on, synchronized with arrival at home
PM
(during sleeping hours)
Settings
ON 64°F
ON 64°F
ON 64°F
ON 64°F
ON 64°F
ON 64°F
ON 64°F
Automatically lowers temperature at bedtime for energy-saving operation at night
Pattern Settings: Input up to four settings for each day Settings: • Start/Stop operation • Temperature setting ✽ The operation mode cannot be set.
Easy set-up using dedicated buttons The remote controller is equipped with buttons that are used exclusively for setting the Weekly Timer. Setting operation patterns is easy and quick.
PUSH
How to set the Weekly Timer
PUSH
Complete
PUSH
Select the day
Ready to set PUSH
Select ON/OFF
PUSH
Select the time
PUSH
Select the period
PUSH
Set the temperature
• Start by pushing the SET button and follow the instructions to set the desired patterns. Once all of the desired patterns are input, point the top end of the remote controller at the indoor unit and push the SET button one more time. (Push the SET button only after inputting all of the desired patterns into the remote controller memory. Pushing the CANCEL button will end the set-up process without sending the operation patterns to the indoor unit). • It takes a few seconds to transmit the Weekly Timer operation patterns to the indoor unit. Please continue to point the remote controller at the indoor unit until all data has been sent.
53
Easy Installation Industry Leading Slim Body The EZ FIT™ can be installed within standard joists that span 16 inches on center. There is no need for large-scale construction, such as the cutting of the joist.
within 16 inches
Temporary hanging hook Work efficiency has improved during installation.
Push the unit to one side Secure the opposite side
Secure one side
Move unit to the center
Drain Piping Supporters + Drain Cover Industry leading slim body realized a simple design with linear beauty. Drain piping
19-11/16in.
Easy joint connections!
Insulation-free cover collects condensation in the drain pan.
Insulating material wrapping only required from this point
No need for wrapping
Insulating material pretreatment eliminates need for wrapping.
Wireless Interface Installation
Drain cover
(Optional)
The indoor unit panel is equipped with a Wireless Interface pocket, contributing to the beautiful appearance, easy installation and maintenance.
Wireless Interface pocket
54
MLZ Model Outdoor Unit
Indoor Unit
Remote Controller
SUZ-KA09/12NA2
MLZ-KP09/12/18NA
Panel
SUZ-KA18NA2
MLP-444W
*Requires MLP-444W grille
Air Purifying
Weekly
Wi-Fi
Interface
Timer
Optional
Optional
Optional
Optional
10°C
Sleep
Optional
Indoor Unit
MLZ-KP09NA
MLZ-KP12NA
MLZ-KP18NA
Outdoor Unit
SUZ-KA09NA2
SUZ-KA12NA2
SUZ-KA18NA2
Cooling
Capacity
Rated 1
BTU/H
9,000
12,000
18,000
Capacity Range
Min-Max
BTU/H
3,600–9,000
3,900–12,000
6,600–18,000
Power Input
Rated 1
W
710
960
1,440
Moisture Removal
Pints/h
1.5
2.8
5.3
0.820
0.740
0.670
Sensible Heat Factor
Heating
Capacity at 47ºF
Rated 2
BTU/H
12,000
15,400
20,000
Capacity Range
Min-Max
BTU/H
4,010–13,000
4,600–17,000
8,200–22,800
Power Input at 47ºF
Rated 2
W
860
1,300
1,170
Rated 3
BTU/H
7,700
9,900
13,100
Max
BTU/H
7,700
9,900
13,100
Max 4
BTU/H
6,100
7,900
10,700
SEER
19.5
19.8
22.3
EER
12.6
12.5
12.5
HSPF
13.3
12.1
12.4
COP
4.0
3.4
3.3
ENERGY STAR® Certified
Yes
Yes
Yes
Capacity at 17ºF Capacity at 5ºF
Efficiency
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Indoor Unit
Dimensions
212–254–283–311
212–258–297–332
212–293–346–403
CFM
180–216–240–264
180–219–252–282
180–249–294–343
Dry
CFM
212–247–290–325
212–272–311–350
212–311–364–417
Cooling
dB(A)
27–31–34–38
27–32–36–40
29–36–41–47
Heating
dB(A)
26–29–34–37
26–32–36–40
26–37–42–48
In. W.G.
—
—
—
19-11/16 [500]
19-11/16 [500]
19-11/16 [500]
Max Distance In. [mm] H
In. [mm]
7-5/16 [185]
7-5/16 [185]
7-5/16 [185]
W
In. [mm]
43-3/8 [1102]
43-3/8 [1102]
43-3/8 [1102]
D
In. [mm]
14-3/16 [360]
14-3/16 [360]
14-3/16 [360]
34 [15.5]
34 [15.5]
34 [15.5] 14.0
Weight
lbs [kg]
MCA
A
9.0
9.0
MOCP
A
15
16
24
Dimensions
H
In. [mm]
21-5/8 [550]
21-5/8 [550]
34-5/8 [880]
W
In. [mm]
31-1/2 [800]
31-1/2 [800]
33-1/16 [840]
D
In. [mm]
11-1/4 [285]
11-1/4 [285]
13 [330]
81 [37]
81 [37]
127 [58]
1228/1172
1228/1172
1691/1691 54
Weight
lbs [kg]
Air Flow Rate (Cooling/Heating)
CFM
Sound Pressure Level
Diameter Piping
Electrical
CFM
Wet
External Static Pressure Condensate Lift Mechanism
Outdoor Unit
Dry
Cooling
dB(A)
48
49
Heating
dB(A)
50
51
55
Gas (O.D.)
In. [mm]
3/8 [9.52]
3/8 [9.52]
1/2 [12.7]
Liquid (O.D)
In. [mm]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
Indoor Drain
In. [mm]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32] 100 [30]
Max. Length
ft [m]
65 [20]
65 [20]
Max. Height
ft [m]
40 [12]
40 [12]
50 [15]
Outdoor-Indoor 5
V, ph, Hz
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
Recommended Breaker Size A
Refrigerant Type Cooling 6 Guaranteed Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
ºF DB [ºC DB] ºF DB [ºC DB]
15
15
15
R410A
R410A
R410A
14.0 to 115.0 [-10.0 to 46.0] -4.0 to -75.0 [-20.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -4.0 to -75.0 [-20.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -4.0 to -75.0 [-20.0 to 24.0]
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 1 2 3
55
MLZ Model Outdoor Unit
Indoor Unit
Remote Controller
MLZ-KP09/12/18NA
SUZ-KA09/12/18NAHZ
Panel
MLP-444W
*Requires MLP-444W grille
Air Purifying
Weekly
Wi-Fi
Interface
Timer
Optional
Optional
Indoor Unit Outdoor Unit
Cooling
MLZ-KP18NA SUZ-KA18NAHZ
BTU/H
9,000
12,000
16,700
4,800–9,000
5,270–12,000
8,740–16,700
Power Input
Rated 1
W
720
940
1,335
Moisture Removal
Pints/h
1.8
3.1
5.1
0.780
0.710
0.660
Capacity at 47ºF
Rated 2
BTU/H
12,000
15,000
18,600
Capacity Range
Min-Max
BTU/H
8,300–14,000
7,800–18,000
8,500–22,000
Power Input at 47ºF
Rated 2
W
840
1,130
1,780
Rated 3
BTU/H
6,600
9,100
11,800
Max
BTU/H
12,000
15,000
18,600
Max 4
BTU/H
12,000
15,000
18,600
SEER
18.9
19.0
18.8
EER
12.5
12.7
12.5
HSPF
11
10.2
10
COP
4.1
3.8
3.0
Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Yes
Yes
Yes
Dry
CFM
212–254–283–311
212–258–297–332
212–293–346–403
Wet
CFM
180–216–240–264
180–219–252–282
180–249–294–343
Dry
CFM
212–247–290–325
212–272–311–350
212–311–364–417
Cooling
dB(A)
27–31–34–38
27–32–36–40
29–36–41–47
Heating
dB(A)
26–29–34–37
26–32–36–40
26–37–42–48
In. W.G.
—
—
—
19-11/16 [500]
19-11/16 [500]
19-11/16 [500]
External Static Pressure Condensate Lift Mechanism Dimensions
Max Distance In. [mm] H
In. [mm]
7-5/16 [185]
7-5/16 [185]
7-5/16 [185]
W
In. [mm]
43-3/8 [1102]
43-3/8 [1102]
43-3/8 [1102]
D
In. [mm]
14-3/16 [360]
14-3/16 [360]
14-3/16 [360]
34 [15.5]
34 [15.5]
34 [15.5] 17.0
Weight
lbs [kg]
MCA
A
14.0
14.0
MOCP
A
24
24
31
Dimensions
H
In. [mm]
34-5/8 [880]
34-5/8 [880]
34-5/8 [880]
W
In. [mm]
38-1/16 [840]
33-1/16 [840]
33-1/16 [840]
D
In. [mm]
13 [330]
13 [330]
13 [330]
129 [58.5]
129 [58.5]
131 [59.5]
Weight
lbs [kg]
Air Flow Rate (Cooling/Heating)
CFM
Sound Pressure Level
Diameter Piping
1,691/1,691
1,691/1,691
2,020/1,930
Cooling
dB(A)
54
54
55
Heating
dB(A)
55
55
55
Gas (O.D.)
In. [mm]
3/8 [9.52]
3/8 [9.52]
1/2 [12.7]
Liquid (O.D)
In. [mm]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
Indoor Drain
In. [mm]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32] 100 [30]
Max. Length
ft [m]
65 [20]
65 [20]
Max. Height
ft [m]
40 [12]
40 [12]
50 [15]
Outdoor-Indoor 5
V, ph, Hz
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
Recommended Breaker Size A
Refrigerant Type Cooling 6 Guaranteed Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
56
MLZ-KP12NA SUZ-KA12NAHZ
BTU/H
ENERGY STAR® Certified
Electrical
MLZ-KP09NA SUZ-KA09NAHZ Rated 1
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi)
Outdoor Unit
Sleep
Min-Max
Capacity at 5ºF
Indoor Unit
10°C
Optional
Capacity
Capacity at 17ºF
Efficiency
Optional
Capacity Range
Sensible Heat Factor
Heating
Optional
ºF DB [ºC DB] ºF DB [ºC DB]
15
15
20
R410A
R410A
R410A
14.0 to 115.0 [-10.0 to 46.0] -13.0 to -75.0 [-25.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -13.0 to -75.0 [-25.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -13.0 to -75.0 [-25.0 to 24.0]
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 1 2 3
SVZ Model
SVZ-KP12/18/24/30/36NA
The multi-position air handler is well-suited for supplemental or replacement applications, and allows for effective and efficient air conditioning as airflow strength can be set to ensure any desired comfort level.
Slim Design Industry leading quality and compact design.
or Multi-position Air Handler
Wall-mounted
Attic
MXZ
Bedroom
Bedroom
Kitchen
Bedroom
Living Room
Sunroom
Flexibility
Quiet
Small Footprint
The SVZ air handler is truly multipositional unit offering up, down*, left or right airflow, making it ideal for tight and unique spaces.
The DC motor ensures quiet and efficient operation year round.
The SVZ’s compact design makes it possible to replace any kind of existing furnace or air handler, and can also be hidden in a closet or basement corner. The single-zone and mutli-zone outdoor units are compact as well, since up to eight indoor units can be connected to one outdoor unit.
*Downflow kit required for downflow installations
57
SVZ Model Outdoor Unit
Indoor Unit
SUZ-KA12NA2
SVZ-KP12/18/24/30/36NA
SUZ-KA18/24/30/36NA2 * To confirm compatibility with the MXZ Model multi-zone system, refer to MXZ Model page.
USNAP
Air Filter Optional
Optional
Optional
Indoor Unit Outdoor Unit
Cooling
SVZ-KP24NA
SVZ-KP30NA
SVZ-KP36NA
SUZ-KA24NA2
SUZ-KA30NA2
SUZ-KA36NA2
BTU/H
12,000
18,000
24,000
27,000
33,000
4,300–12,000
6,200–18,000
12,400–24,000
13,500–27,000
11,600–33,000
Power Input
Rated 1
W
940
1,360
1,920
2,160
3,720
Moisture Removal
Pints/h
1.2
2.4
4.1
2.4
4.7
0.890
0.850
0.810
0.900
0.840
Capacity at 47ºF
Rated 2
BTU/H
15,000
21,600
25,000
30,000
33,500
Capacity Range
Min-Max
BTU/H
4,700–16,700
8,300–26,000
14,600–28,000
12,640–33,000
13,260–36,000
Power Input at 47ºF
Rated 2
W
1,210
1,600
1,910
2,060
3,030
Rated 3
BTU/H
9,900
14,000
14,600
21,400
23,200
Max
BTU/H
9,900
14,000
14,600
21,400
23,200
Max 4
BTU/H
7,800
12,200
—
—
—
18.0
18.0
18.0
18.0
16.0
EER
12.7
13.2
12.5
12.5
8.8
HSPF
12.10
12.60
10.40
13.60
11.70 3.2
COP
3.6
3.9
3.8
4.2
ENERGY STAR® Certified
Yes
Yes
Yes
Yes
No
278–381–448
471–573–675
515–625–735
613–744–875
767–910–910
Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Dry Wet
CFM
—
—
—
—
—
CFM
278–381–448
471–573–675
515–625–735
613–744–875
767–910–910
Cooling
dB(A)
29–36–39
33–36–41
30–34–38
32–46–40
35–39–43
Heating
dB(A)
29–36–39
33–36–41
30–34–38
32–46–40
35–39–43
In. W.G.
0.3–0.5–0.8
0.3–0.5–0.8
0.3–0.5–0.8
0.3–0.5–0.8
0.3–0.5–0.8
Max Distance In. [mm] H
Dimensions
CFM
Dry
External Static Pressure Condensate Lift Mechanism
In. [mm]
—
—
—
—
—
39-13/16 [1011]
39-13/16 [1011]
39-13/16 [1011]
43-3/4 [1111]
43-3/4 [1111]
W
In. [mm]
17 [432]
17 [432]
17 [432]
21 [533]
21 [533]
D
In. [mm]
21-5/8 [548]
21-5/8 [548]
21-5/8 [549]
21-5/8 [549]
21-5/8 [549]
Weight
lbs [kg]
93 [42]
93 [42]
93 [42]
119 [54]
119 [54]
MCA
A
9.0
14.0
17.0
17.0
17.0
MOCP
A
16
24
31
31
31
In. [mm]
21-5/8 [550]
34-5/8 [880]
34-5/8 [880]
34-5/8 [880]
34-5/8 [880]
W
In. [mm]
31-1/2 [800]
33-1/16 [840]
33-1/16 [840]
33-1/16 [840]
33-1/16 [840]
D
In. [mm]
11-1/4 [285]
13 [330]
13 [330]
13 [330]
13 [330]
81 [37]
127 [58]
129 [58.5]
129 [58.5]
129 [58.5] 2020/1930
H Dimensions Weight Air Flow Rate (Cooling/Heating) Sound Pressure Level
Diameter Piping
lbs [kg]
1228/1172
1691/1691
2020/1930
2020/1930
Cooling
CFM dB(A)
49
54
55
55
55
Heating
dB(A)
51
55
55
55
55 5/8 [15.88]
Gas (O.D.)
In. [mm]
3/8 [9.52]
1/2 [12.7]
5/8 [15.88]
5/8 [15.88]
Liquid (O.D)
In. [mm]
1/4 [6.35]
1/4 [6.35]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
Indoor Drain
In. [mm]
3/4 [19.05]
3/4 [19.05]
3/4 [19.05]
3/4 [19.05]
3/4 [19.05]
Max. Length
ft [m]
65 [20]
100 [30]
100 [30]
100 [30]
100 [30]
Max. Height
ft [m]
40 [12]
50 [15]
100 [30]
100 [30]
100 [30]
Outdoor-Indoor 5
V, ph, Hz
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
15
15
20
20
20
R410A
R410A
R410A
R410A
R410A
14.0 to 115.0 [-10.0 to 46.0] -4.0 to -75.0 [-20.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -4.0 to -75.0 [-20.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] 14.0 to -75.0 [-10.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] 14.0 to -75.0 [-10.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] 14.0 to -75.0 [-10.0 to 24.0]
Recommended Breaker Size A
Refrigerant Type Cooling 6 Guaranteed Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
58
SVZ-KP18NA SUZ-KA18NA2
BTU/H
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi)
Electrical
SVZ-KP12NA SUZ-KA12NA2 Min-Max
SEER
Outdoor Unit
Optional
Rated 1
Capacity at 17ºF
Indoor Unit
Optional
Capacity Range
Capacity at 5ºF
Efficiency
T-STAT Optional
Capacity
Sensible Heat Factor
Heating
Optional
ºF DB [ºC DB] ºF DB [ºC DB]
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 1 2 3
SVZ Model Outdoor Unit
Indoor Unit
SVZ-KP12/18NA
SUZ-KA12/18NAHZ * To confirm compatibility with the MXZ Model multi-zone system, refer to MXZ Model page.
USNAP
Air Filter Optional
Optional
Optional
Indoor Unit Outdoor Unit
Cooling
SVZ-KP18NA SUZ-KA18NAHZ
BTU/H
12,000
18,000
BTU/H
5,600–12,000
9,360–18,000
Power Input
Rated 1
W
860
1,440
Moisture Removal
Pints/h
0.8
1.1
0.920
0.930
Capacity at 47ºF
Rated 2
BTU/H
15,000
21,600
Capacity Range
Min-Max
BTU/H
7,700–18,000
8,800–28,000
Power Input at 47ºF
Rated 2
W
1,130
1,880
Rated 3
BTU/H
8,900
14,300
Max
BTU/H
15,000
21,600
Max 4
BTU/H
15,000
21,600
SEER
19.0
18.4
EER
13.9
12.5 10.4
HSPF
10.2
COP
3.8
3.3
ENERGY STAR® Certified
Yes
Yes 471–573–675
Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Dry
CFM
278–381–448
Wet
CFM
—
—
Dry
CFM
278–381–448
471–573–675
Cooling
dB(A)
29–36–39
33–36–41
Heating
dB(A)
29–36–39
33–36–41
In. W.G.
0.3–0.5–0.8
0.3–0.5–0.8
External Static Pressure Condensate Lift Mechanism
Max Distance In. [mm] H
Dimensions
In. [mm]
—
—
39-13/16 [1011]
39-13/16 [1011]
W
In. [mm]
17 [432]
17 [432]
D
In. [mm]
21-5/8 [548]
21-5/8 [548]
Weight
lbs [kg]
93 [42]
93 [42]
MCA
A
14.0
17.0
MOCP
A
24
31
Dimensions
H
In. [mm]
34-5/8 [880]
34-5/8 [880]
W
In. [mm]
33-1/16 [840]
33-1/16 [840]
D
In. [mm]
13 [330]
13 [330]
129 [58.5]
131 [59.5]
1,691/1,691
2,020/1,930
Weight
lbs [kg]
Air Flow Rate (Cooling/Heating)
CFM
Sound Pressure Level
Diameter Piping
Electrical
SVZ-KP12NA SUZ-KA12NAHZ Min-Max
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi)
Outdoor Unit
Optional
Rated 1
Capacity at 17ºF
Indoor Unit
Optional
Capacity Range
Capacity at 5ºF
Efficiency
T-STAT Optional
Capacity
Sensible Heat Factor
Heating
Optional
Cooling
dB(A)
54
55
Heating
dB(A)
55
55 1/2 [12.7]
Gas (O.D.)
In. [mm]
3/8 [9.52]
Liquid (O.D)
In. [mm]
1/4 [6.35]
1/4 [6.35]
Indoor Drain
In. [mm]
3/4 [19.05]
3/4 [19.05] 100 [30]
Max. Length
ft [m]
65 [20]
Max. Height
ft [m]
40 [12]
50 [15]
Outdoor-Indoor 5
V, ph, Hz
208/230, 1, 60
208/230, 1, 60
Recommended Breaker Size A
Refrigerant Type Cooling 6 Guaranteed Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
ºF DB [ºC DB] ºF DB [ºC DB]
15
20
R410A
R410A
14.0 to 115.0 [-10.0 to 46.0] -13.0 to -75.0 [-25.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -13.0 to -75.0 [-25.0 to 24.0]
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 1 2 3
59
SLZ Model
SLZ-KA09/12/15/18NA
Compact, lightweight ceiling cassette units with 4-way air outlets provide maximum comfort by evenly distributing airflow throughout the entire room.
Flexibility The attractive SLZ Model ceiling cassette units offer a slim width and a 4-way air outlet. The size and shape are a perfect match for ceilings made using 2’×2’ construction and its light weight package makes installation easy. SLZ-KF12NA2
22-7/16 ”
16-17/32
The compact body matches 2’×2’ ceiling construction specifications.
22-7/16 ”
22-7/16
Suspension LEG
Bolt to bolt 20-7/8
8-3/16
Suspension bolt T-bar
9-21/32
Unit 22-7/16 22-11/16 23-5/8
Ceiling panel
(unit: in.)
✽ Access door is required
Fresh-air Intake A duct hole is provided in the main body, making it possible to intake fresh air from outside. Intake-air volume
Static pressure: P [in. W.G.×10-2] 20 Fresh-air intake
0 Detail drawing of fresh-air intake 3-15/16 3- 1/8 hole Burring hole
60
80
100
-20 -40
0°
-80
°
12
4-21/32
120
Electrical box
60
2 - 7/ 8 Cut-out hole
40
-60
Drain pipe
Refrigerant pipe
1
Airflow: Q [CFM] 20
-100 -120
Ceiling surface
Note: Fresh-air intake amount should be 20% or less of whole air amount to prevent dew dripping. Booster fan required.
120
Heat Caulking Fixing Method
SLZ-KF Model Outdoor Unit
Indoor Unit
SLZ-KF09/12/15/18NA
Remote Controller
SUZ-KA09/12/15NA2
*optional PAR-SL100A-E
*optional PAR-CT01MAU-SB
*optional PAC-YT53CRAU-J
SUZ-KA18NA2
Panel
SLP-18FAU (standard grille) SLP-18FAEU (3D i-see Sensor® grille)
*optional PAR-40MAAU
*optional MHK2
USNAP Optional
Indoor Unit Outdoor Unit
Cooling
SLZ-KF09NA
SLZ-KF12NA
SLZ-KF15NA
SLZ-KF18NA
SUZ-KA09NA2
SUZ-KA12NA2
SUZ-KA15NA2
SUZ-KA18NA2
BTU/H
9,000
12,000
14,100
17,700
BTU/H
3,600–9,000
3,900–12,000
5,100–14,100
6,100–17,700
Power Input
Rated 1
W
670
900
1,150
1,410
Moisture Removal
Pints/h
1.0
2.8
3.2
4.7
0.870
0.740
0.750
0.710
Capacity at 47ºF
Rated 2
BTU/H
11,000
13,000
18,000
19,700
Capacity Range
Min-Max
BTU/H
4,010–12,000
4,800–13,000
5,100–19,100
8,400–20,900
Power Input at 47ºF
Rated 2
W
4,010
4,800
5,100
8,400
Rated 3
BTU/H
6,900
8,900
11,900
12,900
Max
BTU/H
6,900
8,900
11,900
12,900
Max 4
BTU/H
5,600
6,100
8,900
9,800
SEER
22.4
22.0
19.8
20.7
EER
13.4
13.3
12.2
12.5
HSPF
12.2
11.4
11.2
11.6
COP
3.9
2.9
3.0
3.1
ENERGY STAR® Certified
Yes
Yes
No
Yes
Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Dry
CFM
230–265–300
230–265–335
245–315–405
300–420–475
Wet
CFM
207–239–270
207–252–302
221–284–365
270–378–429
Dry
CFM
230–265–335
230–265–335
245–315–405
300–420–475
Cooling
dB(A)
25–28–31
25–30–34
27–34–39
32–40–43
Heating
dB(A)
25–28–31
25–30–34
27–34–39
32–40–43
In. W.G.
—
—
—
—
33 [850]
33 [850]
33 [850]
33 [850]
External Static Pressure Condensate Lift Mechanism Dimensions
Max Distance In. [mm] H
In. [mm]
9-21/32 [245]
9-21/32 [245]
9-21/32 [245]
9-21/32 [245]
W
In. [mm]
22-7/16 [570]
22-7/16 [570]
22-7/16 [570]
22-7/16 [570]
D
In. [mm]
22-7/16 [570]
22-7/16 [570]
22-7/16 [570]
22-7/16 [570]
31 [13.9]
31 [13.9]
31 [13.9]
31 [13.9] 14.0
Weight
lbs [kg]
MCA
A
9.0
9.0
10.0
MOCP
A
15
16
18
24
Dimensions
H
In. [mm]
21-5/8 [550]
21-5/8 [550]
21-5/8 [550]
34-5/8 [880]
W
In. [mm]
31-1/2 [800]
31-1/2 [800]
31-1/2 [800]
33-1/16 [840]
D
In. [mm]
11-1/4 [285]
11-1/4 [285]
11-1/4 [285]
13 [330]
81 [37]
81 [37]
81 [37]
127 [58]
1228/1172
1228/1172
1243/1229
1691/1691 54
Weight
lbs [kg]
Air Flow Rate (Cooling/Heating)
CFM
Sound Pressure Level
Diameter Piping
Electrical
Optional
Rated 1
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi)
Outdoor Unit
Optional
Min-Max
Capacity at 5ºF
Indoor Unit
T-STAT Optional
Optional
Capacity
Capacity at 17ºF
Efficiency
Optional
Capacity Range
Sensible Heat Factor
Heating
Optional
Cooling
dB(A)
48
49
49
Heating
dB(A)
50
51
51
55
Gas (O.D.)
In. [mm]
3/8 [9.52]
3/8 [9.52]
1/2 [12.7]
1/2 [12.7]
Liquid (O.D)
In. [mm]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
Indoor Drain
In. [mm]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32] 100 [30]
Max. Length
ft [m]
65 [20]
65 [20]
65 [20]
Max. Height
ft [m]
40 [12]
40 [12]
40 [12]
50 [15]
Outdoor-Indoor 5
V, ph, Hz
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
Recommended Breaker Size A
Refrigerant Type Cooling 6 Guaranteed Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
ºF DB [ºC DB] ºF DB [ºC DB]
15
15
15
15
R410A
R410A
R410A
R410A
14.0 to 115.0 [-10.0 to 46.0] -4.0 to -75.0 [-20.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -4.0 to -75.0 [-20.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -4.0 to -75.0 [-20.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -4.0 to -75.0 [-20.0 to 24.0]
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 1 2 3
61
Heat Caulking Fixing Method
SLZ-KF Model Outdoor Unit
Indoor Unit
Remote Controller
SLZ-KF09/12/15/18NA *optional PAR-CT01MAU-SB
Panel
*optional PAC-YT53CRAU-J *optional PAR-40MAAU
SLP-18FAU (standard grille)
SUZ-KA09/12/15/18NAHZ
SLP-18FAEU (3D i-see Sensor® grille)
*optional PAR-SL100A-E
USNAP Optional
Indoor Unit Outdoor Unit
Cooling
SLZ-KF09NA
SLZ-KF12NA
SLZ-KF15NA
SLZ-KF18NA
SUZ-KA09NAHZ
SUZ-KA12NAHZ
SUZ-KA15NAHZ
SUZ-KA18NAHZ
9,000
12,000
13,700
16,800
BTU/H
4,800–9,000
5,070–12,000
8,500–13,700
9,010–16,800
Power Input
Rated 1
W
600
940
1,095
1,340
Moisture Removal
Pints/h
1.9
3.1
3.4
4.2
0.770
0.710
0.720
0.720
Capacity at 47ºF
Rated 2
BTU/H
11,000
13,800
16,400
18,800
Capacity Range
Min-Max
BTU/H
7,400–13,200
7,800–14,500
8,300–19,000
8,300–20,000
Power Input at 47ºF
Rated 2
W
820
1,170
1,830
2,020
Rated 3
BTU/H
6,300
8,300
9,700
12,100
Max
BTU/H
11,000
13,800
16,400
18,800
Max 4
BTU/H
11,000
13,800
16,400
18,800
SEER
20.2
20.3
17.7
19.0
EER
15.0
12.7
12.5
12.5
HSPF
10
10
9
9.4
COP
3.9
3.4
2.6
2.7
ENERGY STAR® Certified
Yes
Yes
Yes
Yes
Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Dry
CFM
230–265–300
230–265–335
245–315–405
300–420–475
Wet
CFM
207–239–270
207–252–302
221–284–365
270–378–429
Dry
CFM
230–265–335
230–265–335
245–315–405
300–420–475
Cooling
dB(A)
25–28–31
25–30–34
27–34–39
32–40–43
Heating
dB(A)
25–28–31
25–30–34
27–34–39
32–40–43
In. W.G.
—
—
—
—
33 [850]
33 [850]
33 [850]
33 [850]
External Static Pressure Condensate Lift Mechanism Dimensions
Max Distance In. [mm] H
In. [mm]
9-21/32 [245]
9-21/32 [245]
9-21/32 [245]
9-21/32 [245]
W
In. [mm]
22-7/16 [570]
22-7/16 [570]
22-7/16 [570]
22-7/16 [570]
D
In. [mm]
22-7/16 [570]
22-7/16 [570]
22-7/16 [570]
22-7/16 [570]
31 [13.9]
31 [13.9]
31 [13.9]
31 [13.9] 17.0
Weight
lbs [kg]
MCA
A
14.0
14.0
17.0
MOCP
A
24
24
31
31
Dimensions
H
In. [mm]
34-5/8 [880]
34-5/8 [880]
34-5/8 [880]
34-5/8 [880]
W
In. [mm]
38-1/16 [840]
33-1/16 [840]
33-1/16 [840]
33-1/16 [840]
D
In. [mm]
13 [330]
13 [330]
13 [330]
13 [330]
129 [58.5]
129 [58.5]
131 [59.5]
131 [59.5]
Weight
lbs [kg]
Air Flow Rate (Cooling/Heating)
CFM
Sound Pressure Level
Diameter Piping
1,691/1,691
1,691/1,691
2,020/1,930
2,020/1,930
Cooling
dB(A)
54
54
55
55
Heating
dB(A)
55
55
55
55
Gas (O.D.)
In. [mm]
3/8 [9.52]
3/8 [9.52]
1/2 [12.7]
1/2 [12.7]
Liquid (O.D)
In. [mm]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
Indoor Drain
In. [mm]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32] 100 [30]
Max. Length
ft [m]
65 [20]
65 [20]
65 [20]
Max. Height
ft [m]
40 [12]
40 [12]
40 [12]
50 [15]
Outdoor-Indoor 5
V, ph, Hz
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
Recommended Breaker Size A
Refrigerant Type Cooling 6 Guaranteed Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
ºF DB [ºC DB] ºF DB [ºC DB]
15
15
20
20
R410A
R410A
R410A
R410A
14.0 to 115.0 [-10.0 to 46.0] -13.0 to -75.0 [-25.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -13.0 to -75.0 [-25.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -13.0 to -75.0 [-25.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -13.0 to -75.0 [-25.0 to 24.0]
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
62
Optional
BTU/H
Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi)
Electrical
Optional
Rated 1
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi)
Outdoor Unit
T-STAT Optional
Optional
Min-Max
Capacity at 5ºF
Indoor Unit
Optional
Capacity
Capacity at 17ºF
Efficiency
Optional
Capacity Range
Sensible Heat Factor
Heating
*optional MHK2
1 2 3
SEZ Model
SEZ-KD09/12/15/18NA4
This concealed ceiling-mounted indoor unit model is compact, and fits easily into rooms with lowered ceilings. Highly reliable energy-saving performance makes it a best match choice for concealed unit installations.
Compact Ceiling-concealed Units Only the intake-air grille and outlet vents are visible when using this ceiling-concealed indoor unit. The rest of the unit is conveniently hidden in the ceiling cavity, essentially leaving the ceiling and walls free of bulky looking devices and maintaining a high-class interior dĂŠcor. The compact units require minimal space and can be installed in buildings with lowered ceilings, where exposed units were the rule in the past.
A
F
B
E
C D E F
B
D
C
G
A
G
Air inlet Air outlet Access door Ceiling surface Canvas duct Air filter Inlet grille
Selection of Fan Speeds and Static Pressure Levels Three fan speed settings (Low, Medium and High) and four static pressure levels are available for all capacities.
Static Pressure Levels SEZ-KD09-18NA4
Sound Levels
0.02-0.06-0.14-0.20 In.W.G.
Low
Medium
High
09
23 dB(A)
26 dB(A)
30 dB(A)
12
23 dB(A)
28 dB(A)
33 dB(A)
15
30 dB(A)
34 dB(A)
37 dB(A)
18
30 dB(A)
34 dB(A)
38 dB(A)
63
Heat Caulking Fixing Method
SEZ-KD Model Outdoor Unit
Indoor Unit
Remote Controller
SUZ-KA09/12/15NA2
*optional PAR-CT01MAU-SB
*optional PAC-YT53CRAU-J
*optional MHK2
*optional PAR-40MAAU SEZ-KD09/12/15/18NA4
*optional
SUZ-KA18NA2 VAQ
USNAP Optional
Indoor Unit Outdoor Unit
Cooling
SEZ-KD09NA4R1
SEZ-KD12NA4R1
SEZ-KD15NA4R1
SEZ-KD18NA4R1
SUZ-KA09NA2
SUZ-KA12NA2
SUZ-KA15NA2
SUZ-KA18NA2
15,000
18,000
Capacity Range
Min-Max
BTU/H
3,900–9,000
4,000–12,000
5,200–15,000
6,100–18,000
Power Input
Rated 1
W
700
930
1,150
1,310
Moisture Removal
Pints/h
1.5
1.9
1.9
2.8
0.820
0.820
0.860
0.820
Capacity at 47ºF
Rated 2
BTU/H
12,000
15,000
18,000
21,600
Capacity Range
Min-Max
BTU/H
4,200–12,800
4,800–16,800
5,000–21,600
8,100–25,600
Power Input at 47ºF
Rated 2
W
1,100
1,330
1,440
1,580
Rated 3
BTU/H
7,600
10,000
11,700
13,900
Max
BTU/H
6,700
9,000
11,900
13,100
Max 4
BTU/H
6,000
7,900
10,000
12,000
SEER
18.8
20.5
19.0
22.0
EER
12.8
12.9
13.0
13.7
HSPF
11.00
12.40
11.40
13.10
COP
3.1
3.3
3.6
4.0
ENERGY STAR® Certified
Yes
Yes
Yes
Yes
Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Dry
CFM
194–247–317
247–317–388
353–441–529
423–529–635
Wet
CFM
174–222–285
222–285–349
317–396–476
381–476–572
Dry
CFM
194–247–317
247–317–388
353–441–529
423–529–635
Cooling
dB(A)
23–26–30
23–28–33
30–34–37
30–34–38
Heating
dB(A)
23–26–30
23–28–33
30–34–37
30–34–38
In. W.G.
0.02–0.06–0.14–0.2
0.02–0.06–0.14–0.2
0.02–0.06–0.14–0.2
0.02–0.06–0.14–0.2 21-21/32 [550]
External Static Pressure Condensate Lift Mechanism Dimensions
2121/32 [550]
21-21/32 [550]
21-21/32 [550]
H
Max Distance In. [mm] In. [mm]
7-7/8 [200]
7-7/8 [200]
7-7/8 [200]
7-7/8 [200]
W
In. [mm]
31-7/8 [790]
39 [990]
39 [990]
46-7/8 [1190]
D
In. [mm]
27-9/16 [700]
27-9/16 [700]
27-9/16 [700]
27-9/16 [700]
42 [19.0]
50 [22.0]
54 [24.0]
62 [28.0] 14.0
Weight
lbs [kg]
MCA
A
9.0
9.0
10.0
MOCP
A
15
16
18
24
Dimensions
H
In. [mm]
21-5/8 [550]
21-5/8 [550]
21-5/8 [550]
34-5/8 [880]
W
In. [mm]
31-1/2 [800]
31-1/2 [800]
31-1/2 [800]
33-1/16 [840]
D
In. [mm]
11-1/4 [285]
11-1/4 [285]
11-1/4 [285]
13 [330]
81 [37]
81 [37]
81 [37]
127 [58]
1228/1172
1228/1172
1243/1229
1691/1691 54
Weight
lbs [kg]
Air Flow Rate (Cooling/Heating)
CFM
Sound Pressure Level
Diameter Piping
Cooling
dB(A)
48
49
49
Heating
dB(A)
50
51
51
55
Gas (O.D.)
In. [mm]
3/8 [9.52]
3/8 [9.52]
1/2 [12.7]
1/2 [12.7]
Liquid (O.D)
In. [mm]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
Indoor Drain
In. [mm]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32] 100 [30]
Max. Length
ft [m]
65 [20]
65 [20]
65 [20]
Max. Height
ft [m]
40 [12]
40 [12]
40 [12]
50 [15]
Outdoor-Indoor 5
V, ph, Hz
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
Recommended Breaker Size A
Refrigerant Type Cooling 6 Guaranteed Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
ºF DB [ºC DB] ºF DB [ºC DB]
15
15
15
15
R410A
R410A
R410A
R410A
14.0 to 115.0 [-10.0 to 46.0] -4.0 to -75.0 [-20.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -4.0 to -75.0 [-20.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -4.0 to -75.0 [-20.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -4.0 to -75.0 [-20.0 to 24.0]
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
64
Optional
Optional
12,000
Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi)
Electrical
Optional
9,000
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi)
Outdoor Unit
T-STAT Optional
BTU/H
Capacity at 5ºF
Indoor Unit
Optional
Rated 1
Capacity at 17ºF
Efficiency
Optional
Capacity
Sensible Heat Factor
Heating
Optional
1 2 3
Heat Caulking Fixing Method
SEZ-KD Model Outdoor Unit
Indoor Unit
Remote Controller
*optional PAR-CT01MAU-SB
*optional PAR-40MAAU
SUZ-KA09/12/15/18NAHZ
SEZ-KD09/12/15/18NA4
*optional PAC-YT53CRAU-J
*optional MHK2
*optional VAQ
USNAP Optional
Optional
Optional
Optional
T-STAT Optional
Optional
Optional
Optional
Indoor Unit
SEZ-KD09NA4R1
SEZ-KD12NA4R1
SEZ-KD15NA4R1
SEZ-KD18NA4R1
Outdoor Unit
SUZ-KA09NAHZ
SUZ-KA12NAHZ
SUZ-KA15NAHZ
SUZ-KA18NAHZ
Cooling
Capacity
Rated 1
BTU/H
9,000
12,000
15,000
18,000
Capacity Range
Min-Max
BTU/H
4,500–9,000
5,210–12,000
9,000–15,000
9,200–18,000
Power Input
Rated 1
W
690
920
1,200
1,370
Moisture Removal
Pints/h
1.7
2.5
2.8
2.0
0.790
0.760
0.800
0.870
Sensible Heat Factor
Heating
Capacity at 47ºF
Rated 2
BTU/H
12,500
15,000
18,000
21,600
Capacity Range
Min-Max
BTU/H
8,100–13,300
7,700–18,000
8,600–22,400
8,800–28,000
Power Input at 47ºF Capacity at 17ºF
1,920
1,840
12,200
14,200
BTU/H
12,500
15,000
18,000
21,600
12,500
15,000
18,000
21,600
SEER
17.3
19.0
17.3
19.1
EER
13.0
13.0
12.5
13.1
HSPF
9.8
10.2
9.5
10.9
COP
2.8
3.9
2.7
3.4
ENERGY STAR® Certified
Yes
Yes
Yes
Yes
Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Dry
CFM
194–247–317
247–317–388
353–441–529
423–529–635
Wet
CFM
174–222–285
222–285–349
317–396–476
381–476–572
Dry
CFM
194–247–317
247–317–388
353–441–529
423–529–635
Cooling
dB(A)
23–26–30
23–28–33
30–34–37
30–34–38
Heating
dB(A)
23–26–30
23–28–33
30–34–37
30–34–38
In. W.G.
0.02–0.06–0.14–0.2
0.02–0.06–0.14–0.2
0.02–0.06–0.14–0.2
0.02–0.06–0.14–0.2 21-21/32 [550]
External Static Pressure Condensate Lift Mechanism Dimensions
2121/32 [550]
21-21/32 [550]
21-21/32 [550]
H
Max Distance In. [mm] In. [mm]
7-7/8 [200]
7-7/8 [200]
7-7/8 [200]
7-7/8 [200]
W
In. [mm]
31-7/8 [790]
39 [990]
39 [990]
46-7/8 [1190]
D
In. [mm]
27-9/16 [700]
27-9/16 [700]
27-9/16 [700]
27-9/16 [700]
42 [19.0]
50 [22.0]
54 [24.0]
62 [28.0] 17.0
Weight
lbs [kg]
MCA
A
14.0
14.0
17.0
MOCP
A
24
24
31
31 34-5/8 [880]
Dimensions
H
In. [mm]
34-5/8 [880]
34-5/8 [880]
34-5/8 [880]
W
In. [mm]
38-1/16 [840]
33-1/16 [840]
33-1/16 [840]
33-1/16 [840]
D
In. [mm]
13 [330]
13 [330]
13 [330]
13 [28-3/4 (730)]
Weight
lbs [kg]
Air Flow Rate (Cooling/Heating)
CFM
Sound Pressure Level
Diameter Piping
Electrical
1,120 9,000
BTU/H
Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi)
Outdoor Unit
1,300 8,700
Max 4
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi)
Indoor Unit
W BTU/H
Max
Capacity at 5ºF
Efficiency
Rated 2 Rated 3
129 [58.5]
129 [58.5]
131 [59.5]
131 [59.5]
1,691/1,691
1,691/1,691
2,020/1,930
2,020/1,930 55
Cooling
dB(A)
54
54
55
Heating
dB(A)
55
55
55
55
Gas (O.D.)
In. [mm]
3/8 [9.52]
3/8 [9.52]
1/2 [12.7]
1/2 [12.7]
Liquid (O.D)
In. [mm]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
Indoor Drain
In. [mm]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32] 100 [30]
Max. Length
ft [m]
65 [20]
65 [20]
65 [20]
Max. Height
ft [m]
40 [12]
40 [12]
40 [12]
50 [15]
Outdoor-Indoor 5
V, ph, Hz
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
Recommended Breaker Size A
Refrigerant Type Cooling 6 Guaranteed Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
ºF DB [ºC DB] ºF DB [ºC DB]
15
15
20
20
R410A
R410A
R410A
R410A
14.0 to 115.0 [-10.0 to 46.0] -13.0 to -75.0 [-25.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -13.0 to -75.0 [-25.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -13.0 to -75.0 [-25.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -13.0 to -75.0 [-25.0 to 24.0]
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 1 2 3
65
PEAD Model The thin, ceiling-concealed indoor units of this model are the perfect answer for the air conditioning needs of buildings with minimum ceiling installation space and wide-ranging external static pressure. Energy-saving efficiency has been improved, reducing electricity consumption and contributing to a further reduction in operating cost.
PEAD-A12/18/24/30/36/42AA7
Compact Indoor Units
External Static Pressure
The height is only 9-7/8" for all sizes of this model from 12 to 42 kBTU/H. This makes it possible for the unit to be installed in low ceilings with minimal clearance space.
External static pressure conversion can be set up to five settings. Capable of being set to a maximum of 0.60 In.W.G., units are applicable to a wide range of building types. ď Ž External static pressure Model
12
PEAD-A AA
18
24
30
36
42
0.14-0.20-0.28-0.40-0.60 In. W.G.
High Energy Efficiency SEER/HSPF has been greatly improved, and 12,000/18,000 BTU/H models have been added to the line-up. AA5 Series
SEER
AA7 Series
AA5 Series
HSPF
21.1 19.6
19.1
19.1
10.2 16.0
15.5
10.2
10.2 9.8
16.1 15.0
18
24
30
36
42
9.9
10.0 10.0
9.4
13.8
12
10.8
10.8 19.9
AA7 Series
12
18
24
30
36
42
Built-in Drain Lift Mechanism All models feature a built-in drain lift mechanism for removal of condensate. The unit’s fail-safe mechanism recognizes when there is a high liquid level in the condensate pan and turns off the indoor fan and the outdoor unit compressor to prevent overflow.
66
Heat Caulking Fixing Method
PEAD Model Outdoor Unit
Indoor Unit
Remote Controller *optional PAR-CT01MAU-SB
SUZ-KA09/12/15NA2
*optional PAC-YT53CRAU-J
*optional MHK2
*optional PAR-40MAAU
PEAD-A09/12/15/18/24/30/36AA7
SUZ-KA18/24/30/36NA2
*optional
VAQ
USNAP Optional
Optional
Optional
Optional
T-STAT Optional
Optional
Optional
Optional
Indoor Unit
PEAD-A09AA7
PEAD-A12AA7
PEAD-A15AA7
PEAD-A18AA7
PEAD-A24AA7
PEAD-A30AA7
PEAD-A36AA7
Outdoor Unit
SUZ-KA09NA2
SUZ-KA12NA2
SUZ-KA15NA2
SUZ-KA18NA2
SUZ-KA24NA2
SUZ-KA30NA2
SUZ-KA36NA2
Cooling
Capacity
Rated 1
BTU/H
9,000
12,000
15,000
18,000
24,000
27,000
33,000
Capacity Range
Min-Max
BTU/H
4,300–9,000
4,400–12,000
5,500–15,000
6,200–18,000
12,000–24,000
13,200–27,000
14,000–33,000
Power Input
Rated 1
W
720
930
1,150
1,270
1,920
2,160
3,510
Moisture Removal
Pints/h
0.8
1.1
1.3
3.2
4.9
3.9
4.8
0.900
0.900
0.900
0.800
0.770
0.840
0.840
Sensible Heat Factor
Heating
Capacity at 47ºF
Rated 2
BTU/H
12,000
15,000
18,000
21,600
25,000
30,000
33,400
Capacity Range
Min-Max
BTU/H
3,960–13,000
4,800–17,000
4,900–21,500
8,120–25,600
14,400–28,000
15,860–33,000
14,750–36,000
Power Input at 47ºF
Rated 2
W
900
1,160
1,350
1,600
1,990
2,410
3,170
Rated 3
BTU/H
7,600
9,900
11,300
14,000
15,000
22,400
23,000
Max
BTU/H
7,600
9,900
11,300
14,000
15,000
22,400
23,100
Max 4
BTU/H
6,100
7,900
10,100
12,000
—
—
—
19.7
20.5
19.2
19.8
18.0
18.0
16.0
EER
12.5
12.9
13.0
14.1
12.5
12.5
9.4
HSPF
12.6
13
11.6
12.9
11.2
12.6
11.6
Capacity at 17ºF Capacity at 5ºF SEER Efficiency
COP
3.9
3.7
3.9
3.9
3.6
3.6
3.0
ENERGY STAR® Certified
Yes
Yes
Yes
Yes
Yes
Yes
Yes 847–1024–1201
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Indoor Unit
Dry
CFM
282–318–353
353–424–494
424–512–600
424–512–600
512–636–742
618–742–883
Wet
CFM
254–286–318
318–382–445
382–461–540
382–461–540
461–572–667
556–668–795
762–922–1081
Dry
CFM
282–318–353
353–424–494
424–512–600
424–512–600
512–636–742
618–742–883
847–1024–1201
Cooling
dB(A)
24–26–28
28–30–34
30–33–37
30–33–37
30–33–37
30–34–39
33–38–42
Heating
dB(A)
24–26–28
28–30–34
30–33–37
30–33–37
30–33–37
30–34–39
33–38–42
In. W.G.
0.14–0.2–0.28– 0.4–0.6
0.14–0.2–0.28– 0.4–0.6
0.14–0.2–0.28– 0.4–0.6
0.14–0.2–0.28– 0.4–0.6
0.14–0.2–0.28– 0.4–0.6
0.14–0.2–0.28– 0.4–0.6
0.14–0.2–0.28– 0.4–0.6 27-9/16 [700]
External Static Pressure Condensate Lift Mechanism
279/16 [700]
27-9/16 [700]
279/16 [700]
27-9/16 [700]
27-9/16 [700]
27-9/16 [700]
H
Max Distance In. [mm] In. [mm]
9-7/8 [250]
9-7/8 [250]
9-7/8 [250]
9-7/8 [250]
9-7/8 [250]
9-7/8 [250]
9-7/8 [250]
Dimensions
W
In. [mm]
35-7/16 [900]
35-7/16 [900]
35-7/16 [900]
35-7/16 [900]
43-5/16 [1100]
43-5/16 [1100]
55-1/8 [1400]
D
In. [mm]
28-7/8 [732]
28-7/8 [732]
28-7/8 [732]
28-7/8 [732]
28-7/8 [732]
28-7/8 [732]
28-7/8 [732]
Weight
lbs [kg]
58 [26]
58 [26]
62 [28]
62 [28]
69 [31]
69 [31]
86 [39]
MCA
A
9.0
9.0
10.0
14.0
17.0
17.0
17.0
MOCP
A
15
16
18
24
31
31
31
In. [mm]
21-5/8 [550]
21-5/8 [550]
21-5/8 [550]
34-5/8 [880]
34-5/8 [880]
34-5/8 [880]
34-5/8 [880]
W
In. [mm]
31-1/2 [800]
31-1/2 [800]
31-1/2 [800]
33-1/16 [840]
33-1/16 [840]
33-1/16 [840]
33-1/16 [840]
D
In. [mm]
11-1/4 [285]
11-1/4 [285]
11-1/4 [285]
13 [330]
13 [330]
13 [330]
13 [330]
81 [37]
81 [37]
81 [37]
127 [58]
129 [58.5]
129 [58.5]
129 [58.5] 2020/1930
H Dimensions Outdoor Unit
Weight Air Flow Rate (Cooling/Heating) Sound Pressure Level
Diameter Piping
Electrical
lbs [kg]
1228/1172
1228/1172
1243/1229
1691/1691
2020/1930
2020/1930
Cooling
CFM dB(A)
48
49
49
54
55
55
55
Heating
dB(A)
50
51
51
55
55
55
55
Gas (O.D.)
In. [mm]
3/8 [9.52]
3/8 [9.52]
1/2 [12.7]
1/2 [12.7]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
Liquid (O.D)
In. [mm]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
Indoor Drain
In. [mm]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32]
Max. Length
ft [m]
65 [20]
65 [20]
65 [20]
100 [30]
100 [30]
100 [30]
100 [30]
Max. Height
ft [m]
40 [12]
40 [12]
40 [12]
50 [15]
100 [30]
100 [30]
100 [30]
Outdoor-Indoor 5
V, ph, Hz
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
15
15
15
15
20
20
20
R410A
R410A
R410A
R410A
R410A
R410A
R410A
14.0 to 115.0 [-10.0 to 46.0] -4.0 to -75.0 [-20.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -4.0 to -75.0 [-20.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -4.0 to -75.0 [-20.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -4.0 to -75.0 [-20.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] 14.0 to -75.0 [-10.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] 14.0 to -75.0 [-10.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] 14.0 to -75.0 [-10.0 to 24.0]
Recommended Breaker Size A
Refrigerant Type Cooling 6 Guaranteed Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
ºF DB [ºC DB] ºF DB [ºC DB]
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 1 2 3
67
Heat Caulking Fixing Method
PEAD Model Outdoor Unit
Indoor Unit
Remote Controller
*optional PAR-CT01MAU-SB
*optional PAC-YT53CRAU-J
*optional MHK2
*optional PAR-40MAAU
PEAD-A09/12/15/18AA7
SUZ-KA09/12/15/18NAHZ *optional VAQ
USNAP Optional
Optional
Indoor Unit Outdoor Unit
Cooling
PEAD-A09AA7
PEAD-A12AA7
PEAD-A15AA7
PEAD-A18AA7
SUZ-KA09NAHZ
SUZ-KA12NAHZ
SUZ-KA15NAHZ
SUZ-KA18NAHZ
9,000
12,000
15,000
18,000
BTU/H
5,000–9,000
5,770–12,000
9,600–15,000
9,320–18,000
Power Input
Rated 1
W
650
850
1,190
1,400
Moisture Removal
Pints/h
1.4
1.9
2.4
3.6
0.820
0.820
0.820
0.780
Capacity at 47ºF
Rated 2
BTU/H
12,000
15,000
18,000
21,600
Capacity Range
Min-Max
BTU/H
8,200–14,000
7,900–18,000
8,800–23,000
8,800–28,000
Power Input at 47ºF
Rated 2
W
910
1,100
1,710
1,890
Rated 3
BTU/H
6,800
9,000
11,700
14,200
Max
BTU/H
12,000
15,000
18,000
21,600
Max 4
BTU/H
12,000
15,000
18,000
21,600
SEER
17.8
19.3
18.3
18.9
EER
13.8
14.1
12.6
12.8
HSPF
10.8
11
9.9
10.8
COP
3.8
3.9
3.0
3.3
ENERGY STAR® Certified
Yes
Yes
Yes
Yes
Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Dry
CFM
282–318–353
353–424–494
424–512–600
424–512–600
Wet
CFM
254–286–318
318–382–445
382–461–540
382–461–540
Dry
CFM
282–318–353
353–424–494
424–512–600
424–512–600
Cooling
dB(A)
24–26–28
28–30–34
30–33–37
30–33–37
Heating
dB(A)
24–26–28
28–30–34
30–33–37
30–33–37
In. W.G.
0.14–0.2–0.28–0.4–0.6
0.14–0.2–0.28–0.4–0.6
0.14–0.2–0.28–0.4–0.6
0.14–0.2–0.28–0.4–0.6 27-9/16 [700]
External Static Pressure Condensate Lift Mechanism Dimensions
279/16 [700]
27-9/16 [700]
279/16 [700]
H
Max Distance In. [mm] In. [mm]
9-7/8 [250]
9-7/8 [250]
9-7/8 [250]
9-7/8 [250]
W
In. [mm]
35-7/16 [900]
35-7/16 [900]
35-7/16 [900]
35-7/16 [900]
D
In. [mm]
28-7/8 [732]
28-7/8 [732]
28-7/8 [732]
28-7/8 [732]
58 [26]
58 [26]
62 [28]
62 [28] 17.0
Weight
lbs [kg]
MCA
A
14.0
14.0
17.0
MOCP
A
24
24
31
31
Dimensions
H
In. [mm]
34-5/8 [880]
34-5/8 [880]
34-5/8 [880]
34-5/8 [880]
W
In. [mm]
38-1/16 [840]
33-1/16 [840]
33-1/16 [840]
33-1/16 [840]
D
In. [mm]
13 [330]
13 [330]
13 [330]
13 [330]
129 [58.5]
129 [58.5]
131 [59.5]
131 [59.5]
Weight
lbs [kg]
Air Flow Rate (Cooling/Heating)
CFM
Sound Pressure Level
Diameter Piping
1,691/1,691
1,691/1,691
2,020/1,930
2,020/1,930
Cooling
dB(A)
54
54
55
55
Heating
dB(A)
55
55
55
55
Gas (O.D.)
In. [mm]
3/8 [9.52]
3/8 [9.52]
1/2 [12.7]
1/2 [12.7]
Liquid (O.D)
In. [mm]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
Indoor Drain
In. [mm]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32] 100 [30]
Max. Length
ft [m]
65 [20]
65 [20]
65 [20]
Max. Height
ft [m]
40 [12]
40 [12]
40 [12]
50 [15]
Outdoor-Indoor 5
V, ph, Hz
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
Recommended Breaker Size A
Refrigerant Type Cooling 6 Guaranteed Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
ºF DB [ºC DB] ºF DB [ºC DB]
15
15
20
20
R410A
R410A
R410A
R410A
14.0 to 115.0 [-10.0 to 46.0] -13.0 to -75.0 [-25.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -13.0 to -75.0 [-25.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -13.0 to -75.0 [-25.0 to 24.0]
14.0 to 115.0 [-10.0 to 46.0] -13.0 to -75.0 [-25.0 to 24.0]
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
68
Optional
BTU/H
Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi)
Electrical
Optional
Rated 1
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi)
Outdoor Unit
Optional
Min-Max
Capacity at 5ºF
Indoor Unit
T-STAT Optional
Capacity
Capacity at 17ºF
Efficiency
Optional
Capacity Range
Sensible Heat Factor
Heating
Optional
1 2 3
69
P
Series
70
SELECTION
Line-up includes a selection of six indoor units and three categories of outdoor units. Easily construct a system that best matches room air conditioning needs.
STEP 1
SELECT INDOOR UNIT Choose from Cooling Only, Heat Pump, or Hyper-heating models.
Wall-mounted PKA-HA Ceiling-concealed PEAD
4-way Ceiling Cassette PLA Wall-mounted PKA-KA
Ceiling-suspended PCA
Multi-position Air Handler PVA
SELECT OUTDOOR UNIT
STEP 2
Choose from Cooling Only, Heat Pump, or Hyper-heating models. Cooling Only
PUY-A12NKA7
PUY-A18NKA7
PUY-A24NHA7
PUY-A30NHA7
PUY-A36NKA7
PUY-A42NKA7
PUZ-A18NKA7
PUZ-A24NHA7
PUZ-A30NHA7
PUZ-A36NKA7
PUZ-A42NKA7
PUZ-HA30NHA5
PUZ-HA36NHA5
PUZ-HA42NKA
Heat Pump
PUZ-A12NKA7
Hyper-heating
PUZ-HA24NHA
71
P-Series
The P-Series is designed to achieve industry-leading seasonal energy-efficiency through use of new technologies and high-performance compressors. Installation is easy thanks to outdoor units with a side-flow configuration, a maximum piping length of 225 ft. PUY only and pipe-replacement technologies.
Industry Leading Energy Efficiency Industry-leading energy efficiency has been achieved through optimization of a newly designed compressor and the use of the latest energysaving technologies. All compressors offer high performance due to advanced variable-speed INVERTER-drive technology, which varies the compressor speed dynamically to continuously adapt to the conditioning requirements of the room. 28 26 24
24.6
24.2
13 22.8
22
21.8
12.8
12 21.0
11
20 18
10
16
9
14
11.0
11.2
11.6 10.4 9.3
8
12 10
HSPF
14
SEER
27.0
7
PLA-A12EA7 PLA-A18EA7 PLA-A24EA7 PLA-A30EA7 PLA-A36EA7 PLA-A42EA7
PLA-A12EA7 PLA-A18EA7 PLA-A24EA7 PLA-A30EA7 PLA-A36EA7 PLA-A42EA7
Advanced Energy-saving Technology Highly efficient fan for outdoor unit
Fan opening of 21-3/4" (A36-42) The opening for the fan in the outdoor unit is 21-3/4" in diameter. By exchanging heat more efficiently, this will contribute to energy-saving and low noise level.
The opening for the fan The is opening for the fan in the outdoor unit in the 3 21- /4" in diameter. outdoor unit is for the fan 3/4" opening 21-The in diameter. in the outdoor unit is 21-3/4" in diameter.
Improved fan (A36-42) A newly designed fan has been adopted, increasing airflow capacity and reducing operation noise.
Fan rear edge
Fan rear edge Fan rear edge
Highly efficient heat exchanger
High-density heat exchanger (A36-42) The A36-42 units use 5/16"-diameter pipe. The high-density heat exchanger contributes to efficient heat exchange and reduces the amount of refrigerant used, which is better for the environment.
2 lines, 64 columns 2 lines, 64 columns (A36-42) (A36-42) 2 lines, 64 columns (A36-42)
72
Cooling Only
PUY Model Low ambient cooling operation range
High Reliability and Performance in Low Ambient Conditions By changing the fan speed control in low ambient temperatures, the PUY model can offer stable operation down to -40° F. This model range is well suited for cooling needs in cold regions. *Optional Air Protection Guide/Wind Baffle is needed when ambient temperature is under 23° F.
Low ambient cooling operation range
High capacity at low ambient condition
Previous model (PUY-A**NKA/NHA6)
Cooling Performance Curve
Previous model (PUY-A**NKA/NHA6)
1.4
115° F to 14° F (46° C to –10° C) CAPACITY (RATIO)
115° F to 14° F (46° C to –10° C)
New model (PUY-A**NKA/NHA7)
New model (PUY-A**NKA/NHA7)
115°FFtoto –40° F (46° to –40° C) 115° –40° F (46° C to C –40° C)
1.2
20°C (68°F) 18°C (64°F) 0.8 -40 (-40°F)
115° F
115° F
14° F
–40° 14° F F –40° F
Quick auto restart after power failure
In case of power failures, the time until auto restart became shorter from 180 seconds to 60 seconds. The unit will quickly restart with the same operation mode as before the power failure.
Previous model (PUY-A**NKA/NHA6)
Previous 180 secondsmodel (PUY-A**NKA/NHA6)
180 seconds New model (PUY-A**NKA/NHA7)
60 seconds New model (PUY-A**NKA/NHA7)
60 seconds
INDOOR W.B. 22°C (72°F)
1.0
16°C (61°F) -30 -28.9 (-20°F)
-20-18* (0°F)
-10
0 (32°F)
20 (68°F)
30 (86°F)
40 (104°F)
46 (115°F)
OUT DOOR D.B. (°C)
Backup rotation function
The two units can operate alternately so the units can maintain their quality for a longer period of time, and so that even if there is trouble with one unit, the other unit will keep operating. *Can only be used with PAR-40MAAU controller ON
UNIT 1
UNIT 2
10 (50°F)
ON OFF
UNIT 1
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
UNIT 2 OFF
ON OFF
Continuous operation
Control algorithm allows for stable continuous operation to meet cooling requirements all year round. The unit will quickly restart with the same operation mode as before the power failure.
73
Heat Pump
PUZ Model Quiet and Comfort Sound level 60 dB(A) 65-75 dB(A) Quiet passenger Traditional heat-pump car interior (40km/h) outdoor unit
40 dB(A) Library interior
30 dB(A)
40 dB(A)
44 dB(A)
50 dB(A)
60 dB(A)
80 dB(A) Subway car interior
70 dB(A)
80 dB(A)
90 dB(A) [Source: In-company investigation]
PUZ Series outdoor unit* *PUZ-A12/18 cooling mode
Energy saving
Not only do all capacities meet standard requirements, but they also are ENERGY STAR ® certified*, with top level efficiency. *With PLA-A12/18/24/36 indoor unit.
All units are inverter-driven, operating efficiently in accordance to the cooling/heating load.
Wide Operation Range Due to the wide operation range, the units can be used in many different climates.
SEER
30 27.0 24.6
25
24.2
22.8
21.8
21.0
20
15
10
PLA-A12EA7 PLA-A18EA7 PLA-A24EA7 PLA-A30EA7 PLA-A36EA7 PLA-A42EA7
Cooling Heating
115° F to 0° F*1 (46° C to –18.8° C) 70° F to -4° F (19° C to –20° C)*2
*1 In case that the air protection guide wind baffle is installed. (In case the wind baffle is not installed, the minimum temperature will be 23° F (–5° C) DB) *2 A24/30/36/42
Flexible Installation Long piping length The long piping length allows them to be installed in unnoticeable places such as rooftops. Piping
74
Length (ft)
Height (ft)
PUZ-A12NKA7
100
100
PUZ-A18NKA7
100
100
PUZ-A24NHA7
165
100
PUZ-A30NHA7
165
100
PUZ-A36NKA7
165
100
PUZ-A42NKA7
165
100
Various types of indoor units With various types of indoor units, there is a perfect match for any type of application, starting from residential homes to restaurants and offices.
Hyper-heating
PUZ-HA Model Improved Heating Performance Our unique Flash Injection circuit achieves remarkably high heating performance. This technology has resulted in an excellent heating capacity rating in outdoor temperatures as low as 5° F, and the guaranteed heating operation range of the heating mode has been extended to -13° F. Accordingly, the hyper-heating PUZ-HA Model are perfect for warming homes in the coldest of regions. Guaranteed heating operation range is extended to -13° F ambient temperature
Approx. 30% higher than model one size larger
Heating capacity (Btu/h)
(example of 30,000 BTUH model) 38,000
PUZ-HA36
30,000
PUZ-HA30
36
-13oF
-4oF
PUZ-HA Series
-13oF
30
PUZ-A
22,000
PUZ Series
-4oF
PUZ-A
5 oF
19oF
32oF
Outdoor-air temperature
-13oF
5oF
-4oF
14oF
23oF
32oF
Enhanced Comfort The Flash Injection circuit improves start-up and recover from the defrosting operation. A newly introduced defrost operation control also improves defrost frequency. These features enable the temperature to reach the set temperature more quickly, and contribute to maintaining it at the desired setting.
Quick Start-up ■ Operation at 36° F outdoor temperature H2i rises quickly, 113° F in 10min
38,000
19min
10min
Normal INV:
30,000
113o F in 19min
Approx. 50% faster 22,000 0
0
5
10
15
20
Operation time (min)
30
Indoor outlet temp.
122°F
86°F
68°F
Room temp.
50 °F
-22°F
10
104°F
86°F
-4°F
22,000
Field Test Results: Office building in Asahikawa, Hokkaido, Japan
140 °F
Indoor outlet temp.
104°F
14°F
113o F in 30min
33% faster
■ Operation data for 2 Dec. 2004
140 °F
32°F
Normal INV:
30,000
0
H2i Defrost Control and Faster Recovery from Defrost Operation ■ Operation data for 25 Jan. 2005
30min
20min
20
Operation time (min)
122°F
H2i rises quickly, 113° F in 20min
(in stable condition)
Stable
Heating capacity (Btu/h)
Heating capacity (Btu/h)
38,000
■ Operation at -4° F outdoor temperature
Discharged air temperature reaches 122o F
18:00
20:00
22:00
0:00
2:00
4:00
6:00
Outdoor temp.
Reduced defrosting operation time from 4 to 3 minutes.
68°F
Room temp.
50 °F
Outdoor temp.
32°F
Installation example
14°F 8:00
10:00
12:00
14:00
16:00
18:00
20:00
22:00
H2i Defrost Control maintained a maximum interval of 150 minutes between defrosting operations at outdoor temperatures of approximately -4° F and 32° F.
75
PLA Model
PLA-A12/18/24/30/36/42EA7
A complete line-up that offer superior energy savings. The incorporation of wide air-outlet and the 3D i-see Sensor® enhances airflow distribution control, achieving an enhanced level of comfort throughout the room. The synergy of higher energy efficiency and more comfortable room environment results in the utmost user satisfaction.
4-way Ceiling Cassette Line-up For users seeking further energy savings, we offer a wide line-up from 12-42 KBTU/H. ■ Key Technologies for Higher Energy Efficiency
■ Line-up Model Series
4-way Cassette (PLA-A)
3D Turbo Fan
12
18
24
30
36
42
PLA-A12EA7
PLA-A18EA7
PLA-A24EA7
PLA-A30EA7
PLA-A36EA7
PLA-A42EA7
By optimizing the fan blade wing design using a three-dimensional shape, efficiency has been improved and operating noise reduced.
■ Indoor/Outdoor Unit Combinations 4-way Cassette PLA-A EA
Power Inverter
PUY/PUZ-A12/18
PUY/PUZ-A24/30
PUY/PUZ-A36/42
PUY-HA24
PUZ-HA30/36
PUZ-HA42
Energy-saving Performance SEER/HSPF has been greatly improved, realizing industry-leading energy-saving features. PLA-BA Series
SEER
PLA-EA Series
PLA-BA Series
HSPF
12.8
27.0 24.6
24.2
22.8
21.8
11.0 21.0
11.2
14.2
76
18
14.0
24
14.0
30
14.2
36
11.6 10.4
9.8 8.5
12
PLA-EA Series
8.7
9.3
9.3 9.3
14.4
42
12
18
24
30
36
42
Horizontal Airflow For users seeking further energy savings, we offer a wide line-up from 12-42 KBTU/H.
Draft reduction vane setting
72 airflow patterns
The newly function Draft Reduction of manual vane setting makes the air flow direction more horizontal than usual horizontal vane setting. It reduces a drafty feeling dramatically.
4-, 3-, or 2- way outlet selection*
*The draft reduction can be set for only 1 vane. PAR-40MAAU is required for this setting.
Individual vane settings 72 patterns of airflow to accommodate any room layout are available. The number of outlet can be set to 4, 3, or 2. Flexible airflow is available by fixing the up-down airflow direction of the outlet with a wired remote controller (or manually).
*Optional parts air outlet shutter plate is required for 2- or 3- way outlet selection.
Setting the air direction for each outlet with wired remote controller Horizontal airflow
Fixed Remote controller setting
Down airflow
Easy Installation Electrical box wiring
Increased space for piping work
After reviewing the power supply terminal position in the electrical box, the structure was redesigned to improve connectivity. This has made previously complex wiring work easier. Previous Model (BA Model)
New Model (EA Model)
The top and bottom positions of the liquid and gas pipes have been reversed to allow the gas pipe work, which requires more effort, to be completed first. Further, through structural innovations related to the space around the pipes, the area where the spanner can be moved has been increased, thus improving liquid pipe work and enabling it to be completed smoothly.
50°
Temporary hanging hook
No need to remove screws
The structure of the panel has been revised and is now equipped with a temporary hanging hook. This has improved work efficiency during panel installation.
Installation is possible without removing the screws for the corner panel and the control box, simply loosen them. This lowers the risk of losing screws. Corner panel
70°
Lightweight decorative panel After reviewing the structure and materials, weight has been reduced approximately 20% compared to the previous model, reducing the burden of installation.
Corner box cover
77
for P-Series Detects number of people
Detects number of people The 3D i-see Sensor® detects the number of people in the room and adjusts the power accordingly. This makes automatic power-saving operation possible in places where the number of people changes frequently. Additionally, when the area is continuously unoccupied, the system switches to a more enhanced power-saving mode. Depending on the setting, it can also stop the operation.
Detects people’s position
Detects position and number of people
Detects people’s position
Detects floor temperature
Once a person is detected, the angle of the vane is automatically adjusted. Each vane can be independently set to Direct Airflow or Indirect Airflow according to taste.
8 sensors
360°
Detection
8 ft. 23 ft. 3 ft. 39ft.
8
7
6
4
53
2
1
1
2
3
4
5
6
7
8
Floor surface
*In case of a 8 ft. ceiling
Detects number of people Room occupancy energy-saving mode The 3D i-see Sensor detects the number of people in the room. It then calculates the occupancy rate based on the maximum number of people in the room up to that point in time in order to save air conditioning power. When the occupancy rate is approximately 30%, air-conditioning power equivalent to 2° F during both cooling and heating operation is saved. The temperature is controlled according to the number of people.
Room occupancy energy save mode
2° F power savings No occupancy energy save mode
No occupancy energy-saving mode When 3D i-see Sensor detects that no one is the room, the system is switched to a pre-set power-saving mode. If the room remains unoccupied for more than 60min, air-conditioning power equivalent to 4° F during both cooling and heating operation is saved. This contributes to preventing waste in terms of heating and cooling.
4° F power savings No occupancy Auto-Off mode
Auto-Off
No occupancy Auto-OFF mode
*PAR-40MAAU is required for each setting
When the room remains unoccupied for a pre-set period of time, the air conditioner turns off automatically, thereby providing even greater power savings. The time until operation is stopped can be set in intervals of 10 min, ranging from 60 to 180 min.
Detects people’s position Direct/Indirect settings*
Seasonal airflow*
The horizontal airflow spreads across the ceiling. When set to Indirect Airflow uncomfortable drafty-feeling is eliminated completely.
When Cooling Saves energy while keeping a comfortable effective temperature by automatically switching between ventilation and cooling. When a pre-set temperature is reached, the air conditioning unit switches to swing fan operation *PAR-40MAAU is required for each setting. to maintain the effective temperature. This clever function contributes to keeping a comfortable coolness.
*PAR-40MAAU is required for each setting.
78
Cooling
Heating
When Heating The air conditioning unit automatically switches between circulator and heating. Wasted heat that accumulates near the ceiling is reused via circulation. When a pre-set temperature is reached the air conditioner switches from heating to circulator and blows air in the horizontal direction. It pushes down the warm air that has gathered near the ceiling to people’s height, thereby providing smart heating.
100-250
35-71
PLA-A Model
JointL ap
Vector Sine Wave
DC Scroll
35-140
DC FanM otor
35-71
Grooved Piping
Vector-Wave
Heat Caulking Fixing Method
MODEL SELECTION Indoor Unit
Outdoor Unit
PLA-A12/18/24/30/36/42EA7
Cooling Only
PUY-A12/18NKA7
PUY-A24/30NHA7
PUY-A36/42NKA7
Heat Pump
PUZ-A12/18NKA7
PUZ-A24/30NHA7
PUZ-A36/42NKA7
PUZ-HA24NHA
PUZ-HA30/36NHA5
Required grille: PLP-40EAEU / PLP-41EAEU
Hyper-heating
PUZ-HA42NKA
Remote Controller
*optional PAR-40MAAU
*optional PAC-YT53CRAU-J
*optional
*optional PAR-CT01MAU-SB
*optional MHK2
79
PLA Model
Optional
Optional
Wi-Fi
COOLING ONLY
Optional
Indoor Unit Outdoor Unit
Cooling
Optional
PLA-A12EA7
PLA-A18EA7
PLA-A24EA7
PLA-A30EA7
PLA-A36EA7
PLA-A42EA7
PUY-A18NKA7(-BS)
PUY-A24NHA7(-BS)
PUY-A30NHA7(-BS)
PUY-A36NKA7(-BS)
PUY-A42NKA7(-BS)
Rated 1
BTU/H
12,000
18,000
24,000
30,000
36,000
42,000
Min-Max
BTU/H
5,800–12,000
8,000–18,000
10,000–24,000
9,000–30,000
16,000–36,000
16,000–42,000
Power Input
Rated 1
W
730
1,250
1,670
2,540
2,780
3,590
Moisture Removal
Pints/h
1.2
2.4
3.0
5.4
4.5
7.9
0.890
0.850
0.860
0.800
0.860
0.790
Capacity at 47ºF
Rated
BTU/H
—
—
—
—
—
—
Capacity Range
Min-Max
BTU/H
—
—
—
—
—
—
Power Input at 47ºF
Rated
W
—
—
—
—
—
—
Rated
BTU/H
—
—
—
—
—
—
Max
BTU/H
—
—
—
—
—
—
Max
BTU/H
—
—
—
—
—
—
SEER
27.0
24.6
24.2
22.8
21.8
21.0
EER
16.4
14.4
14.3
11.8
12.9
11.6
HSPF
—
—
—
—
—
—
COP
—
—
—
—
—
—
Yes
Yes
Yes
No
Yes
No
ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Dry
CFM
420–460–490–530
420–460–570–600
530–640–710–810
570–670–780–880
Wet
CFM
380–420–450–490
380–420–530–560
490–600–670–770
530–630–740–840
Dry
CFM
420–460–490–530
420–460–570–600
530–640–710–810
570–670–780–880
Cooling
dB(A)
27–28–29–30
28–29–31–32
28–30–33–36
28–32–35–38
32–37–41–44
34–38–42–45
Heating
dB(A)
27–28–29–30
28–29–31–32
28–30–33–36
28–32–35–38
32–37–41–44
34–38–42–45
In. W.G.
—
—
—
—
—
—
[849]
[849]
[849]
[849]
[849]
[849]
11-3/4 // 1-9/16 [298 // 40] 33-1/16 // 37-13/32 [840] 33-1/16 // 37-13/32 [840]
11-3/4 // 1-9/16 [298 // 40] 33-1/16 // 37-13/32 [840] 33-1/16 // 37-13/32 [840]
11-3/4 // 1-9/16 [298 // 40] 33-1/16 // 37-13/32 [840] 33-1/16 // 37-13/32 [840]
External Static Pressure Condensate Lift Mechanism
Max Distance In. [mm] H
10-5/32 // 1-9/16 [258 10-5/32 // 1-9/16 [258 10-5/32 // 1-9/16 [258 // 40] // 40] // 40] 33-1/16 // 37-13/32 33-1/16 // 37-13/32 33-1/16 // 37-13/32 In. [mm] [840] [840] [840] 33-1/16 // 37-13/32 33-1/16 // 37-13/32 33-1/16 // 37-13/32 In. [mm] [840] [840] [840] In. [mm]
700–880–1020–1160
Weight
lbs [kg]
46 // 11 [21 // 5]
46 // 11 [21 // 5]
56 // 11 [25 // 5]
56 // 11 [25 // 5]
56 // 11 [25 // 5]
56 // 11 [25 // 5]
MCA
A
11.0
11.0
19.0
19.0
25.0
25.0
MOCP
A
28
28
26
26
31
31
37-1/8 [943]
37-1/8 [943]
52-11/16 [1338]
52-11/16 [1338]
H
In. [mm]
24-13/16 [630]
24-13/16 [630]
W
In. [mm]
31-13/16 (+7/16) [809 (+62)]
31-13/16 (+7/16) [809 (+62)]
37-13/32 [950]
37-13/32 [950]
41-5/16 [1050]
41-5/16 [1050]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
11-3/16 [300]
13 (+1-3/16) [330 (+30)]
Weight
lbs [kg]
92 [41]
99 [44]
151 [68]
151 [68]
211 [96]
211 [96]
Air Flow Rate (Cooling/Heating)
CFM
1590/—
1590/—
1940/—
1940/—
3880/—
3880/— 52
Outdoor Unit
D
Sound Pressure Level
Diameter Piping Max. Length
In. [mm]
dB(A)
44
44
47
47
52
Heating
dB(A)
—
—
—
—
—
—
Gas (O.D.)
In. [mm]
1/2 [12.7]
1/2 [12.7]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
Liquid (O.D)
In. [mm]
1/4 [6.35]
1/4 [6.35]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
Indoor Drain
In. [mm]
—
—
—
—
—
—
165 [50]
165 [50]
225 [68]
225 [68]
225 [68]
225 [68]
ft [m]
Max. Height
ft [m]
Outdoor-Indoor 5
V, ph, Hz
Recommended Breaker Size A
Guaranteed Cooling 6 Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
11-3/16 [300]
Cooling
100 [30]
100 [30]
100 [30]
100 [30]
100 [30]
100 [30]
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
15
15
25
25
30
30
R410A
R410A
R410A
R410A
R410A
R410A
ºF DB [ºC DB]
-40.0 to 115.0 [-40.0 to 46.0]
-40.0 to 115.0 [-40.0 to 46.0]
-40.0 to 115.0 [-40.0 to 46.0]
-40.0 to 115.0 [-40.0 to 46.0]
-40.0 to 115.0 [-40.0 to 46.0]
-40.0 to 115.0 [-40.0 to 46.0]
ºF DB [ºC DB]
—
—
—
—
—
—
Refrigerant Type
1
Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Wind baffles required to operate below 23°F DB in cooling mode. PUY with wind baffle: -40°F - 115°F. Refer to wind baffle documentation for further information. SEACOAST PROTECTION • External Outer Panel: Phosphate coating + Acrylic-Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly; Valve Bed: Epoxy resin coating (at edge face) • “Blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.
80
630–810–980–1160
670–850–1020–1200 740–920–1060–1200
W
Dimensions
5
670–850–1020–1200 740–920–1060–1200
Dimensions
D
Electrical
Optional
Capacity
Capacity at 5ºF
Indoor Unit
Interface
Optional
Capacity Range
Capacity at 17ºF
Efficiency
Optional
PUY-A12NKA7(-BS)
Sensible Heat Factor
Heating
Optional
60-140V/200/250
PUHZ
PLA Model
Optional
Optional
PUHZ
PUHZ
Optional
Outdoor Unit
Optional
Optional
Optional
Optional
PLA-A12EA7
PLA-A18EA7
PLA-A24EA7
PLA-A30EA7
PLA-A36EA7
PLA-A42EA7
PUZ-A12NKA7(-BS)
PUZ-A18NKA7(-BS)
PUZ-A24NHA7(-BS)
PUZ-A30NHA7(-BS)
PUZ-A36NKA7(-BS)
PUZ-A42NKA7(-BS)
Rated 1
BTU/H
12,000
18,000
24,000
30,000
36,000
42,000
Min-Max
BTU/H
5,800–12,000
8,000–18,000
10,000–24,000
9,000–30,000
16,000–36,000
16,000–42,000
Power Input
Rated 1
W
730
1,250
1,670
2,540
2,780
3,590
Moisture Removal
Pints/h
1.2
2.4
3.0
5.4
4.5
7.9
0.890
0.850
0.860
0.800
0.860
0.790
Capacity at 47ºF
Rated 2
BTU/H
14,000
19,000
26,000
32,000
38,000
45,000
Capacity Range
Min-Max
BTU/H
5,500–20,000
7,900–23,000
9,000–29,000
9,000–33,000
18,000–42,000
18,000–48,000
Power Input at 47ºF
Rated 2
W
830
1,300
1,750
2,400
2,540
3,290
Rated 3
BTU/H
10,100
11,000
14,900
18,100
22,000
28,000
Max
BTU/H
12,200
13,500
17,400
20,800
25,500
30,800
Max 4
BTU/H
—
—
—
—
—
—
SEER
27.0
24.6
24.2
22.8
21.8
21.0
EER
16.4
14.4
14.3
11.8
12.9
11.6
HSPF
12.8
11
11.2
11.6
10.4
9.3
COP
4.94
4.28
4.35
3.9
4.38
4.0
ENERGY STAR® Certified
Yes
Yes
Yes
No
Yes
No
Capacity at 5ºF
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Dry
CFM
420–460–490–530
420–460–570–600
530–640–710–810
570–670–780–880
Wet
CFM
380–420–450–490
380–420–530–560
490–600–670–770
530–630–740–840
Dry
CFM
420–460–490–530
420–460–570–600
530–640–710–810
570–670–780–880
Cooling
dB(A)
27–28–29–30
28–29–31–32
28–30–33–36
28–32–35–38
32–37–41–44
34–38–42–45
Heating
dB(A)
27–28–29–30
28–29–31–32
28–30–33–36
28–32–35–38
32–37–41–44
34–38–42–45
In. W.G.
—
—
—
—
—
—
[849]
[849]
[849]
[849]
[849]
[849]
11-3/4 // 1-9/16 [298 // 40] 33-1/16 // 37-13/32 [840] 33-1/16 // 37-13/32 [840]
11-3/4 // 1-9/16 [298 // 40] 33-1/16 // 37-13/32 [840] 33-1/16 // 37-13/32 [840]
11-3/4 // 1-9/16 [298 // 40] 33-1/16 // 37-13/32 [840] 33-1/16 // 37-13/32 [840]
External Static Pressure Condensate Lift Mechanism
Max Distance In. [mm] H
10-5/32 // 1-9/16 [258 10-5/32 // 1-9/16 [258 10-5/32 // 1-9/16 [258 // 40] // 40] // 40] 33-1/16 // 37-13/32 33-1/16 // 37-13/32 33-1/16 // 37-13/32 In. [mm] [840] [840] [840] 33-1/16 // 37-13/32 33-1/16 // 37-13/32 33-1/16 // 37-13/32 In. [mm] [840] [840] [840] In. [mm]
670–850–1020–1200 740–920–1060–1200 630–810–980–1160
700–880–1020–1160
670–850–1020–1200 740–920–1060–1200
Dimensions
W
Weight
lbs [kg]
46 // 11 [21 // 5]
46 // 11 [21 // 5]
56 // 11 [25 // 5]
56 // 11 [25 // 5]
56 // 11 [25 // 5]
56 // 11 [25 // 5]
MCA
A
11.0
11.0
19.0
19.0
25.0
25.0
MOCP
A
28
28
26
26
31
31
37-1/8 [943]
37-1/8 [943]
52-11/16 [1338]
52-11/16 [1338]
D
Dimensions Outdoor Unit
H
In. [mm]
24-13/16 [630]
24-13/16 [630]
W
In. [mm]
31-13/16 (+7/16) [809 (+62)]
31-13/16 (+7/16) [809 (+62)]
37-13/32 [950]
37-13/32 [950]
41-5/16 [1050]
41-5/16 [1050]
11-3/16 [300]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
D Weight
lbs [kg]
Air Flow Rate (Cooling/Heating)
CFM
Sound Pressure Level
Diameter Piping Max. Length
Electrical
Optional
Capacity Range
Capacity at 17ºF
Indoor Unit
PUHZ
Capacity
Sensible Heat Factor
Efficiency
PUHZ
PUHZ
Interface
Indoor Unit
Heating
SUZ
Wi-Fi
HEAT PUMP
Cooling
Optional PUHZ
93 [42]
100 [45]
153 [69]
153 [69]
214 [97]
214 [97]
1590/1590
1590/1590
1940/1940
1940/1940
3880/3880
3880/3880 52
dB(A)
44
44
47
47
52
Heating
dB(A)
46
46
48
48
53
53
Gas (O.D.)
In. [mm]
1/2 [12.7]
1/2 [12.7]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
Liquid (O.D)
In. [mm]
1/4 [6.35]
1/4 [6.35]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
Indoor Drain
In. [mm]
—
—
—
—
—
—
100 [30]
100 [30]
165 [50]
165 [50]
165 [50]
165 [50]
ft [m] ft [m]
Outdoor-Indoor 5
V, ph, Hz
Recommended Breaker Size A
Refrigerant Type
Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
11-3/16 [300]
Cooling
Max. Height
Cooling 6 Guaranteed Temperature Operation Range Heating
In. [mm]
ºF DB [ºC DB] ºF DB [ºC DB]
100 [30]
100 [30]
100 [30]
100 [30]
100 [30]
100 [30]
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
15
15
25
25
30
30
R410A
R410A
R410A
R410A
R410A
R410A
0.0 to 115.0 [-18.0 to 46.0] 12.0 to 70.0 [-11.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] 12.0 to 70.0 [-11.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -4.0 to 70.0 [-20.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -4.0 to 70.0 [-20.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -4.0 to 70.0 [-20.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -4.0 to 70.0 [-20.0 to 21.0]
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Wind baffles required to operate below 23°F DB in cooling mode. PUZ with wind baffle: 0° F - 115° F. Refer to wind baffle documentation for further information. SEACOAST PROTECTION • External Outer Panel: Phosphate coating + Acrylic-Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly; Valve Bed: Epoxy resin coating (at edge face) • “Blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. 1 2 3
81
PLA Model
Optional
Optional
Indoor Unit Outdoor Unit
PLA-A24EA7
PLA-A30EA7
PLA-A36EA7
PLA-A42EA7
PUZ-HA24NHA
PUZ-HA30NHA5
PUZ-HA36NHA5
PUZ-HA42NKA
BTU/H
24,000
30,000
36,000
42,000
BTU/H
10,000–24,000
18,000
18,000
19,000
Power Input
Rated 1
W
1,710
2,400
2,850
4,160
Moisture Removal
Pints/h
3.0
7.2
7.1
10.9
0.860
0.730
0.710
0.710
Capacity at 47ºF
Rated 2
BTU/H
26,000
32,000
38,000
48,000
Capacity Range
Min-Max
BTU/H
10,000–28,000
18,000–34,000
18,000–40,000
21,000–54,000
Power Input at 47ºF
Rated 2
W
1,700
3,330
3,130
4,560
Rated 3
BTU/H
17,300
19,000
28,000
44,000
Max
BTU/H
26,000
32,000
38,000
48,000
Max 4
BTU/H
26,000
32,000
38,000
48,000
SEER
21.5
15.6
17.0
14.8
EER
14.0
12.5
12.6
10.1
HSPF
12
9.4
10
10
COP
4.31
2.72
3.44
3.02
ENERGY STAR® Certified
Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Yes
Yes
Yes
No
Dry
CFM
530–640–710–810
570–670–780–880
670–850–1020–1200
740–920–1060–1200
Wet
CFM
490–600–670–770
530–630–740–840
630–810–980–1160
700–880–1020–1160
Dry
CFM
530–640–710–810
570–670–780–880
670–850–1020–1200
740–920–1060–1200
Cooling
dB(A)
28–30–33–36
28–32–35–38
32–37–41–44
34–38–42–45
Heating
dB(A)
28–30–33–36
28–32–35–38
32–37–41–44
34–38–42–45
In. W.G.
—
—
—
—
[849]
[849]
[849]
[849]
External Static Pressure Condensate Lift Mechanism Dimensions
Max Distance In. [mm] H
In. [mm]
10-5/32 // 1-9/16 [258 // 40]
11-3/4 // 1-9/16 [298 // 40]
11-3/4 // 1-9/16 [298 // 40]
11-3/4 // 1-9/16 [298 // 40]
W
In. [mm]
33-1/16 // 37-13/32 [840]
33-1/16 // 37-13/32 [840]
33-1/16 // 37-13/32 [840]
33-1/16 // 37-13/32 [840]
D
In. [mm]
33-1/16 // 37-13/32 [840]
33-1/16 // 37-13/32 [840]
33-1/16 // 37-13/32 [840]
33-1/16 // 37-13/32 [840]
56 // 11 [25 // 5]
56 // 11 [25 // 5]
56 // 11 [25 // 5]
56 // 11 [25 // 5] 37.0
Weight
lbs [kg]
MCA
A
19.0
28.0
28.0
MOCP
A
26
40
40
44
37-1/8 [943]
53-1/8 [1375]
53-1/8 [1375]
52-11/16 [1338]
Dimensions
H
In. [mm]
W
In. [mm]
37-13/32 [950]
37-3/8 [950]
37-3/8 [950]
41-3/8 [1051]
D
In. [mm]
13 [+1-3/16] [330 [+30]]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
Weight
lbs [kg]
Air Flow Rate (Cooling/Heating)
CFM
Sound Pressure Level
Diameter Piping Max. Length
Electrical
265 [120]
287 [130]
3530/3530
3320/3320 49
dB(A)
52
52
52
dB(A)
53
53
53
51
Gas (O.D.)
In. [mm]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
Liquid (O.D)
In. [mm]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
Indoor Drain
In. [mm]
—
—
—
—
165 [50]
245 [75]
245 [75]
245 [75]
ft [m]
Max. Height
ft [m] V, ph, Hz
Recommended Breaker Size A
Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
265 [120] 3530/3530
Heating
Outdoor-Indoor 5
Cooling 6 Guaranteed Temperature Operation Range Heating
85 [188] 1940/1940
Cooling
Refrigerant Type ºF DB [ºC DB] ºF DB [ºC DB]
100 [30]
100 [30]
100 [30]
100 [30]
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
25
30
30
40
R410A
R410A
R410A
R410A
0.0 to 115.0 [-18.0 to 46.0] -13.0 to 70.0 [-25.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -13.0 to 70.0 [-25.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -13.0 to 70.0 [-25.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -13.0 to 70.0 [-25.0 to 21.0]
Cooling (Indoor // Outdoor) °F Heating at 47°F (Indoor // Outdoor) °F Heating at 17°F (Indoor // Outdoor) °F 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Wind baffles required to operate below 23°F DB in cooling mode. PUZ with wind baffle: 0° F - 115° F.
82
Optional
Rated 1
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi)
Outdoor Unit
Optional
Min-Max
Capacity at 5ºF
Indoor Unit
Interface
Optional
Capacity
Capacity at 17ºF
Efficiency
Optional
Capacity Range
Sensible Heat Factor
Heating
Optional
Wi-Fi
HYPER-HEATING
Cooling
Optional 60-140V/200/250
1 2 3
80 DB, 67 WB // 95 DB, 75 WB 70 DB, 60 WB // 47 DB, 43 WB 70 DB, 60 WB // 17 DB, 15 WB 70 DB, 60 WB // 5 DB, 4 WB
83
PKA-A12/18HA7
PKA Model
The compact, wall-mounted indoor units offer the convenience of simple installation, and a large product line-up (A12-A36 models) ensures a best-match solution. Designed for highly efficient energy savings, the PKA Model is the answer to your air conditioning needs.
PKA-A24/30/36KA7
Flat Panel & Pure White Finish A flat panel design and pure white color that harmonizes with virtually any interior.
PKA-A HA7
Flat panel is easy to clean PKA-A KA7
Compact Indoor Units Indoor unit width has been reduced by as much as 20-1/16" (A36KA7). Units take up much less space, greatly increasing installation possibilities. PKA-A12/18HA7
PKA-A24/30KA7
3-5/8 " DOWN*
*Compared to PKA-A12/18GA
9-1/16 " DOWN*
*Compared to PKA-A24/30FA
PKA-A36KA7
20-1/16 " DOWN*
*Compared to PKA-A36FA
Energy Saving Performance SEER/HSPF has been greatly improved, realizing industry-leading energy-saving features. HA6/KA6 Series
SEER
HA7/KA7 Series
HA6/KA6 Series
HSPF
20.8
19.8
10.8
18.8
18.5
10.2
17.0 15.5
15.3
84
18
24
30
36
11.0
10.2
9.9
9.5
14.0
12
HA7/KA7 Series
21.4
8.9
12
18
24
30
9.3 9.2
36
100-250
35-71
PKA Model
JointL ap
Vector Sine Wave
DC Scroll
35-140
DC FanM otor
35-71
Grooved Piping
Vector-Wave
Heat Caulking Fixing Method
MODEL SELECTION Indoor Unit
Outdoor Unit
PKA-A12/18HA7
PKA-A24/30/36KA7
Cooling Only
PUY-A12/18NKA7
PUY-A24/30NHA7
PUY-A36/42NKA7
Heat Pump
PUZ-A12/18NKA7
PUZ-A24/30NHA7
PUZ-A36/42NKA7
Hyper-heating
PUZ-HA24NHA
PUZ-HA30/36NHA5
Remote Controller
*optional PAR-40MAAU
*optional PAC-YT53CRAU-J
*optional
*optional PAR-CT01MAU-SB
*optional MHK2
85
60-140V/200/250
PKA Model
Optional
Interface Optional
Indoor Unit Outdoor Unit
PKA-A12HA7
PKA-A18HA7
PKA-A24KA7
PKA-A30KA7
PKA-A36KA7
PUY-A12NKA7(-BS)
PUY-A18NKA7(-BS)
PUY-A24NHA7(-BS)
PUY-A30NHA7(-BS)
PUY-A36NKA7(-BS)
BTU/H
12,000
18,000
24,000
30,000
36,000
BTU/H
5,800–12,000
8,000–18,000
10,000–24,000
9,000–30,000
16,000–36,000
Power Input
Rated 1
W
1,000
1,820
1,960
3,150
3,330
Moisture Removal
Pints/h
2.0
5.2
5.0
8.1
9.7
0.810
0.680
0.770
0.700
0.700
Capacity at 47ºF
Rated
BTU/H
—
—
—
—
—
Capacity Range
Min-Max
BTU/H
—
—
—
—
—
Power Input at 47ºF
Rated
W
—
—
—
—
—
Rated
BTU/H
—
—
—
—
—
Max
BTU/H
—
—
—
—
—
Max
BTU/H
—
—
—
—
—
SEER
20.8
18.5
21.4
19.8
18.8
EER
12.0
9.9
12.2
9.5
10.8
HSPF
—
—
—
—
—
COP
—
—
—
—
—
ENERGY STAR® Certified
No
No
No
No
No
Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi)
Dry
CFM
320–370–425
320–370–425
635–705–775
635–705–775
705–810–920
Wet
CFM
290–335–380
290–335–380
570–635–700
570–635–700
635–730–830
Dry
CFM
320–370–425
320–370–425
635–705–775
635–705–775
705–810–920
Cooling
dB(A)
36–40–43
36–40–43
39–42–45
39–42–45
43–46–49
Heating
dB(A)
36–40–43
36–40–43
39–42–45
39–42–45
43–46–49
In. W.G.
—
—
—
—
—
Condensate Lift Mechanism
Max Distance In. [mm]
—
—
—
—
—
H
In. [mm]
11-5/8 [295]
11-5/8 [295]
14-3/8 [365]
14-3/8 [365]
14-3/8 [365]
Dimensions
W
In. [mm]
35-3/8 [898]
35-3/8 [898]
46-1/16 [1170]
46-1/16 [1170]
46-1/16 [1170]
D
In. [mm]
9-13/16 [249]
9-13/16 [249]
11-5/8 [295]
11-5/8 [295]
11-5/8 [295]
Weight
lbs [kg]
29 [13]
29 [13]
46 [21]
46 [21]
46 [21]
MCA
A
11.0
11.0
19.0
19.0
25.0
MOCP
A
28
28
26
26
31
37-1/8 [943]
37-1/8 [943]
52-11/16 [1338]
Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) External Static Pressure
Dimensions Outdoor Unit
H
In. [mm]
24-13/16 [630]
24-13/16 [630]
W
In. [mm]
31-13/16 (+7/16) [809 (+62)]
31-13/16 (+7/16) [809 (+62)]
37-13/32 [950]
37-13/32 [950]
41-5/16 [1050]
D
In. [mm]
11-3/16 [300]
11-3/16 [300]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
Weight
lbs [kg]
92 [41]
99 [44]
151 [68]
151 [68]
211 [96]
Air Flow Rate (Cooling/Heating)
CFM
1590/—
1590/—
1940/—
1940/—
3880/— 52
Sound Pressure Level
Cooling
dB(A)
44
44
47
47
Heating
dB(A)
—
—
—
—
—
In. [mm]
1/2 [12.7]
1/2 [12.7]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
Liquid (O.D)
In. [mm]
1/4 [6.35]
1/4 [6.35]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
Indoor Drain
In. [mm]
5/8 [16]
5/8 [16]
5/8 [16]
5/8 [16]
5/8 [16]
165 [50]
165 [50]
225 [68]
225 [68]
225 [68]
Gas (O.D.) Diameter Piping Max. Length
ft [m]
Max. Height
ft [m]
Outdoor-Indoor 5
V, ph, Hz
Recommended Breaker Size A
Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
100 [30]
100 [30]
100 [30]
100 [30]
100 [30]
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
15
15
25
25
30
R410A
R410A
R410A
R410A
R410A
ºF DB [ºC DB]
-40.0 to 115.0 [-40.0 to 46.0]
-40.0 to 115.0 [-40.0 to 46.0]
-40.0 to 115.0 [-40.0 to 46.0]
-40.0 to 115.0 [-40.0 to 46.0]
-40.0 to 115.0 [-40.0 to 46.0]
ºF DB [ºC DB]
—
—
—
—
—
Refrigerant Type Guaranteed Cooling 6 Temperature Operation Range Heating
1
Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Wind baffles required to operate below 23°F DB in cooling mode. PUY with wind baffle: -40°F - 115°F. Refer to wind baffle documentation for further information. SEACOAST PROTECTION • External Outer Panel: Phosphate coating + Acrylic-Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly; Valve Bed: Epoxy resin coating (at edge face) • “Blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.
86
Optional
Optional
Rated 1
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi)
Electrical
Optional
Min-Max
Capacity at 17ºF
Indoor Unit
Optional
Capacity
Capacity at 5ºF
Efficiency
Optional
Capacity Range
Sensible Heat Factor
Heating
Optional
Wi-Fi
COOLING ONLY
Cooling
Optional
Wi-Fi
PKA Model
Interface Optional
HEAT PUMP
Optional
Indoor Unit Outdoor Unit
Cooling
Optional
PKA-A12HA7
PKA-A18HA7
PKA-A24KA7
PKA-A30KA7
PKA-A36KA7
PUZ-A12NKA7(-BS)
PUZ-A18NKA7(-BS)
PUZ-A24NHA7(-BS)
PUZ-A30NHA7(-BS)
PUZ-A36NKA7(-BS)
BTU/H
12,000
18,000
24,000
30,000
36,000
BTU/H
5,800–12,000
8,000–18,000
10,000–24,000
9,000–30,000
16,000–36,000
Power Input
Rated 1
W
1,000
1,820
1,960
3,150
3,330
Moisture Removal
Pints/h
2.0
5.2
5.0
8.1
9.7
0.810
0.680
0.770
0.700
0.700
Capacity at 47ºF
Rated 2
BTU/H
14,000
19,000
26,000
32,000
38,000
Capacity Range
Min-Max
BTU/H
5,500–18,000
7,700–22,000
9,000–28,000
8,900–34,000
18,200–40,000
Power Input at 47ºF
Rated 2
W
950
1,300
1,750
2,460
2,460
Rated 3
BTU/H
9,200
11,300
15,700
18,300
22,400
Max
BTU/H
11,100
13,900
18,300
21,000
25,900
Max 4
BTU/H
—
—
—
—
—
SEER
20.8
18.5
21.4
19.8
18.8
EER
12.0
9.9
12.2
9.5
10.8
HSPF
10.2
10.2
11
9.9
9.2
COP
4.31
4.28
4.35
3.81
4.52
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi)
Dry
CFM
No
No
No
No
No
320–370–425
320–370–425
635–705–775
635–705–775
705–810–920
Wet
CFM
290–335–380
290–335–380
570–635–700
570–635–700
635–730–830
Dry
CFM
320–370–425
320–370–425
635–705–775
635–705–775
705–810–920
Cooling
dB(A)
36–40–43
36–40–43
39–42–45
39–42–45
43–46–49
Heating
dB(A)
36–40–43
36–40–43
39–42–45
39–42–45
43–46–49
In. W.G.
—
—
—
—
—
Condensate Lift Mechanism
Max Distance In. [mm]
—
—
—
—
—
H
In. [mm]
11-5/8 [295]
11-5/8 [295]
14-3/8 [365]
14-3/8 [365]
14-3/8 [365]
Dimensions
W
In. [mm]
35-3/8 [898]
35-3/8 [898]
46-1/16 [1170]
46-1/16 [1170]
46-1/16 [1170]
D
In. [mm]
9-13/16 [249]
9-13/16 [249]
11-5/8 [295]
11-5/8 [295]
11-5/8 [295]
Weight
lbs [kg]
29 [13]
29 [13]
46 [21]
46 [21]
46 [21]
MCA
A
11.0
11.0
19.0
19.0
25.0
MOCP
A
28
28
26
26
31
37-1/8 [943]
37-1/8 [943]
52-11/16 [1338]
Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) External Static Pressure
Dimensions Outdoor Unit
H
In. [mm]
24-13/16 [630]
24-13/16 [630]
W
In. [mm]
31-13/16 (+7/16) [809 (+62)]
31-13/16 (+7/16) [809 (+62)]
37-13/32 [950]
37-13/32 [950]
41-5/16 [1050]
D
In. [mm]
11-3/16 [300]
11-3/16 [300]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
Weight
lbs [kg]
Air Flow Rate (Cooling/Heating)
CFM
Sound Pressure Level
Diameter Piping
100 [45]
153 [69]
153 [69]
214 [97]
1590/1590
1940/1940
1940/1940
3880/3880
Cooling
dB(A)
44
44
47
47
52
dB(A)
46
46
48
48
53
Gas (O.D.)
In. [mm]
1/2 [12.7]
1/2 [12.7]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
Liquid (O.D)
In. [mm]
1/4 [6.35]
1/4 [6.35]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
Indoor Drain
In. [mm]
5/8 [16]
5/8 [16]
5/8 [16]
5/8 [16]
5/8 [16]
100 [30]
100 [30]
165 [50]
165 [50]
165 [50]
ft [m]
Max. Height
ft [m]
Outdoor-Indoor 5
V, ph, Hz
Recommended Breaker Size A
Refrigerant Type
Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
93 [42] 1590/1590
Heating
Max. Length
Cooling 6 Guaranteed Temperature Operation Range Heating
Optional
Optional
Rated 1
ENERGY STAR® Certified
Electrical
Optional
Min-Max
Capacity at 17ºF
Indoor Unit
Optional
Capacity
Capacity at 5ºF
Efficiency
Optional
Capacity Range
Sensible Heat Factor
Heating
Optional
ºF DB [ºC DB] ºF DB [ºC DB]
100 [30]
100 [30]
100 [30]
100 [30]
100 [30]
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
15
15
25
25
30
R410A
R410A
R410A
R410A
R410A
0.0 to 115.0 [-18.0 to 46.0] 12.0 to 70.0 [-11.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] 12.0 to 70.0 [-11.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -4.0 to 70.0 [-20.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -4.0 to 70.0 [-20.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -4.0 to 70.0 [-20.0 to 21.0]
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Wind baffles required to operate below 23°F DB in cooling mode. PUZ with wind baffle: 0° F - 115° F. Refer to wind baffle documentation for further information. SEACOAST PROTECTION • External Outer Panel: Phosphate coating + Acrylic-Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly; Valve Bed: Epoxy resin coating (at edge face) • “Blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. 1 2 3
87
60-140V/200/250
PKA Model
Optional
HYPER-HEATING
Interface Optional
Indoor Unit Outdoor Unit
Cooling
PKA-A30KA7
PKA-A36KA7
PUZ-HA30NHA5
PUZ-HA36NHA5
24,000
30,000
33,400
BTU/H
10,000–24,000
18,000
18,000
Power Input
Rated 1
W
1,900
2,500
2,790
Moisture Removal
Pints/h
5.0
8.1
8.7
0.770
0.700
0.710
Capacity at 47ºF
Rated 2
BTU/H
26,000
32,000
38,000
Capacity Range
Min-Max
BTU/H
10,000–28,000
18,000–34,000
18,000–40,000
Power Input at 47ºF
Rated 2
W
1,920
2,930
3,410
Rated 3
BTU/H
17,200
19,000
25,000
Max
BTU/H
26,000
32,000
38,000
Max 4
BTU/H
26,000
32,000
38,000
SEER
19.5
16.5
16.2
EER
12.6
12.0
12.0
HSPF
11.2
9.5
10
COP
3.8
3.2
3.26
ENERGY STAR® Certified
Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Yes
No
No
Dry
CFM
635–705–775
635–705–775
705–810–920
Wet
CFM
570–635–700
570–635–700
635–730–830
Dry
CFM
635–705–775
635–705–775
705–810–920
Cooling
dB(A)
39–42–45
39–42–45
43–46–49
Heating
dB(A)
39–42–45
39–42–45
43–46–49
In. W.G.
—
—
—
Max Distance In. [mm]
—
—
—
External Static Pressure Condensate Lift Mechanism Dimensions
H
In. [mm]
14-3/8 [365]
14-3/8 [365]
14-3/8 [365]
W
In. [mm]
46-1/16 [1170]
46-1/16 [1170]
46-1/16 [1170]
D
In. [mm]
11-5/8 [295]
11-5/8 [295]
11-5/8 [295]
46 [21]
46 [21]
46 [21] 28.0
Weight
lbs [kg]
MCA
A
19.0
28.0
MOCP
A
26
40
40
37-1/8 [943]
53-1/8 [1375]
53-1/8 [1375]
Dimensions
H
In. [mm]
W
In. [mm]
37-13/32 [950]
37-3/8 [950]
37-3/8 [950]
D
In. [mm]
13 [+1-3/16] [330 [+30]]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
Weight
lbs [kg]
Air Flow Rate (Cooling/Heating)
CFM
Sound Pressure Level
Diameter Piping Max. Length
Electrical
PKA-A24KA7 PUZ-HA24NHA BTU/H
Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi)
85 [188]
265 [120]
265 [120]
1940/1940
3530/3530
3530/3530 52
Cooling
dB(A)
52
52
Heating
dB(A)
53
53
53
Gas (O.D.)
In. [mm]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
Liquid (O.D)
In. [mm]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
Indoor Drain
In. [mm]
5/8 [16]
5/8 [16]
5/8 [16]
165 [50]
245 [75]
245 [75]
ft [m]
Max. Height
ft [m]
Outdoor-Indoor 5
V, ph, Hz
100 [30]
100 [30]
100 [30]
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
Recommended Breaker Size A
Refrigerant Type Cooling 6 Guaranteed Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
ºF DB [ºC DB] ºF DB [ºC DB]
25
30
30
R410A
R410A
R410A
0.0 to 115.0 [-18.0 to 46.0] -13.0 to 70.0 [-25.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -13.0 to 70.0 [-25.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -13.0 to 70.0 [-25.0 to 21.0]
Cooling (Indoor // Outdoor) °F Heating at 47°F (Indoor // Outdoor) °F Heating at 17°F (Indoor // Outdoor) °F 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Wind baffles required to operate below 23°F DB in cooling mode. PUZ with wind baffle: 0° F - 115° F.
88
Optional
Optional
Min-Max
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi)
Outdoor Unit
Optional
Rated 1
Capacity at 5ºF
Indoor Unit
Optional
Capacity Range
Capacity at 17ºF
Efficiency
Optional
Capacity
Sensible Heat Factor
Heating
Optional
Wi-Fi
1 2 3
80 DB, 67 WB // 95 DB, 75 WB 70 DB, 60 WB // 47 DB, 43 WB 70 DB, 60 WB // 17 DB, 15 WB 70 DB, 60 WB // 5 DB, 4 WB
Optional
89
PVA Model
The PVA air handler is truly multi-positional offering up, down, left or right airflow, making it ideal for tight and unique spaces.
Flexibility The PVA air handler is truly multi-positional* offering up, down, left or right airflow, making it ideal for tight and unique spaces.
High Energy Efficiency The PVA Model has high SEER, and is highly energy efficient compared to outdated unitary air conditioners. SEER
21.4
20.5
20.2
19.0
19.3 18.0
13.07
PVA-A12
PVA-A18
PVA-A24
PVA-A30
*Source : AHRI
PVA-A42
Interlocking Function
Durability
The PVA Model has an output terminal which allows it to interlock with other appliances such as humidifiers and dehumidifiers.
The cabinet is made of galvanized metal with a black ZAM (zinc, aluminum, magnesium) hot dip coated steel finish. The internal fan, coil, piping and circuitry are engineered and designed to work in harmony to provide years of reliable operation.
Thermostat Control Using the Thermostat Interface (PAC-US444CN-1), the user can replace their unitary air conditioner without changing the thermostat.
*CMA accessory recommended for downflow applications.
90
PVA-A36
Average SEER for unitary air conditioners sold in 2006.
100-250
35-71
Power Inverter Model
JointL ap
Vector Sine Wave
DC Scroll
35-140
DC FanM otor
Vector-Wave
35-71
Grooved Piping
Heat Caulking Fixing Method
MODEL SELECTION Indoor Unit
Outdoor Unit
Cooling Only
PUY-A12/18NKA7
PUY-A24/30NHA7
PUY-A36/42NKA7
Heat Pump
PUZ-A12/18NKA7
PUZ-A24/30NHA7
PUZ-A36/42NKA7
PUZ-HA24NHA
PUZ-HA30/36NHA5
PVA-A12/18/24/30/36/42AA7
Hyper-heating
PUZ-HA42NKA
Remote Controller
*optional PAR-40MAAU
*optional PAC-YT53CRAU-J
*optional PAR-CT01MAU-SB
*optional MHK2
91
60-140V/200/250
PVA Model
Optional
Optional
COOLING ONLY
Interface Optional
Optional
Indoor Unit Outdoor Unit
Cooling
Optional
PVA-A12AA7
PVA-A18AA7
PVA-A24AA7
PVA-A30AA7
PVA-A36AA7
PVA-A42AA7
PUY-A18NKA7(-BS)
PUY-A24NHA7(-BS)
PUY-A30NHA7(-BS)
PUY-A36NKA7(-BS)
PUY-A42NKA7(-BS)
Rated 1
BTU/H
12,000
18,000
24,000
30,000
36,000
42,000
Min-Max
BTU/H
4,800–12,000
7,000–18,000
10,000–24,000
10,000–30,000
14,600–36,000
15,000–42,000
Power Input
Rated 1
W
890
1,570
1,960
3,000
3,250
4,150
Moisture Removal
Pints/h
1.2
2.4
3.0
5.4
4.5
7.9
0.770
0.760
0.830
0.740
0.770
0.810
Capacity at 47ºF
Rated
BTU/H
—
—
—
—
—
—
Capacity Range
Min-Max
BTU/H
—
—
—
—
—
—
Power Input at 47ºF
Rated
W
—
—
—
—
—
—
Rated
BTU/H
—
—
—
—
—
—
Max
BTU/H
—
—
—
—
—
—
Max
BTU/H
—
—
—
—
—
—
SEER
21.4
20.2
20.5
19.0
19.3
18.0
EER
13.4
11.4
12.2
10.0
9.8
10.1
HSPF
—
—
—
—
—
—
COP
—
—
—
—
—
—
Yes
No
No
No
No
No 1040–1262–1485
ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Dry
CFM
280–340–400
515–625–735
613–744–875
613–744–875
788–956–1125
Wet
CFM
—
—
—
—
—
—
Dry
CFM
280–340–400
515–625–735
613–744–875
613–744–875
788–956–1125
1040–1262–1485
Cooling
dB(A)
24–28–32
28–33–36
30–34–38
30–34–38
30–34–38
34–38–42
Heating
dB(A)
24–28–32
28–33–36
30–34–38
30–34–38
30–34–38
34–38–42
In. W.G.
0.3–0.5–0.8
0.3–0.5–0.8
0.3–0.5–0.8
0.3–0.5–0.8
0.3–0.5–0.8
0.3–0.5–0.8
External Static Pressure Condensate Lift Mechanism Dimensions
Max Distance In. [mm]
—
—
—
—
—
—
50-1/4 [1275]
50-1/4 [1275]
54-1/4 [1378]
54-1/4 [1378]
59-1/2 [1511]
59-1/2 [1511]
H
In. [mm]
W
In. [mm]
17 [432]
17 [432]
21 [534]
21 [534]
25 [635]
25 [635]
D
In. [mm]
21-5/8 [548]
21-5/8 [548]
21-5/8 [548]
21-5/8 [548]
21-5/8 [548]
21-5/8 [548]
Weight
lbs [kg]
113 [51.2]
113 [51.2]
141 [64]
141 [64]
172 [78]
172 [78]
MCA
A
11.0
11.0
19.0
19.0
25.0
25.0
MOCP
A
28
28
26
26
31
31
37-1/8 [943]
37-1/8 [943]
52-11/16 [1338]
52-11/16 [1338]
Dimensions
H
In. [mm]
24-13/16 [630]
24-13/16 [630]
W
In. [mm]
31-13/16 (+7/16) [809 (+62)]
31-13/16 (+7/16) [809 (+62)]
37-13/32 [950]
37-13/32 [950]
41-5/16 [1050]
41-5/16 [1050]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
11-3/16 [300]
13 (+1-3/16) [330 (+30)]
Weight
lbs [kg]
92 [41]
99 [44]
151 [68]
151 [68]
211 [96]
211 [96]
Air Flow Rate (Cooling/Heating)
CFM
1590/—
1590/—
1940/—
1940/—
3880/—
3880/— 52
Outdoor Unit
D
Sound Pressure Level
Diameter Piping
Electrical
In. [mm]
11-3/16 [300]
Cooling
dB(A)
44
44
47
47
52
Heating
dB(A)
—
—
—
—
—
—
Gas (O.D.)
In. [mm]
1/2 [12.7]
1/2 [12.7]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
Liquid (O.D)
In. [mm]
1/4 [6.35]
1/4 [6.35]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
Indoor Drain
In. [mm]
3/4 FPT [19.05]
3/4 FPT [19.05]
3/4 FPT [19.05]
3/4 FPT [19.05]
3/4 FPT [19.05]
3/4 FPT [19.05] 225 [68]
Max. Length
ft [m]
165 [50]
165 [50]
225 [68]
225 [68]
225 [68]
Max. Height
ft [m]
100 [30]
100 [30]
100 [30]
100 [30]
100 [30]
100 [30]
Outdoor-Indoor 5
V, ph, Hz
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
Recommended Breaker Size A
15
15
25
25
30
30
R410A
R410A
R410A
R410A
R410A
R410A
ºF DB [ºC DB]
-40.0 to 115.0 [-40.0 to 46.0]
-40.0 to 115.0 [-40.0 to 46.0]
-40.0 to 115.0 [-40.0 to 46.0]
-40.0 to 115.0 [-40.0 to 46.0]
-40.0 to 115.0 [-40.0 to 46.0]
-40.0 to 115.0 [-40.0 to 46.0]
ºF DB [ºC DB]
—
—
—
—
—
—
Refrigerant Type Guaranteed Cooling 6 Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
1
Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Wind baffles required to operate below 23°F DB in cooling mode. PUY with wind baffle: -40°F - 115°F. Refer to wind baffle documentation for further information. SEACOAST PROTECTION • External Outer Panel: Phosphate coating + Acrylic-Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly; Valve Bed: Epoxy resin coating (at edge face) • “Blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. 5
92
Optional
Capacity
Capacity at 5ºF
Indoor Unit
Optional
Capacity Range
Capacity at 17ºF
Efficiency
Optional
PUY-A12NKA7(-BS)
Sensible Heat Factor
Heating
Optional
Wi-Fi
Wi-Fi
PVA Model
Interface Optional
HEAT PUMP
Optional
Indoor Unit Outdoor Unit
Cooling
Optional
Optional
Optional
PVA-A12AA7
PVA-A18AA7
PVA-A24AA7
PVA-A30AA7
PVA-A36AA7
PVA-A42AA7
PUZ-A12NKA7(-BS)
PUZ-A18NKA7(-BS)
PUZ-A24NHA7(-BS)
PUZ-A30NHA7(-BS)
PUZ-A36NKA7(-BS)
PUZ-A42NKA7(-BS)
BTU/H
12,000
18,000
24,000
30,000
36,000
42,000
Min-Max
BTU/H
4,800–12,000
7,000–18,000
10,000–24,000
10,000–30,000
14,600–36,000
15,000–42,000
Power Input
Rated 1
W
890
1,570
1,960
3,000
3,250
4,150
Moisture Removal
Pints/h
1.2
2.4
3.0
5.4
4.5
7.9
0.770
0.760
0.830
0.740
0.770
0.810
Capacity at 47ºF
Rated 2
BTU/H
14,000
19,000
26,000
32,000
38,000
46,000
Capacity Range
Min-Max
BTU/H
5,700–19,000
7,700–23,000
12,000–28,000
12,000–34,000
17,700–42,000
18,100–48,000
Power Input at 47ºF
Rated 2
W
1,070
1,470
1,920
2,640
3,030
3,900
Rated 3
BTU/H
9,900
12,000
15,000
18,000
24,000
28,400
Max
BTU/H
12,000
14,700
17,500
20,700
27,800
31,400
Max 4
BTU/H
—
—
—
—
—
—
SEER
21.4
20.2
20.5
19.0
19.3
18.0
EER
13.4
11.4
12.2
10.0
9.8
10.1
HSPF
10.3
10.4
9.3
10
9.5
9.3
COP
3.82
3.78
3.96
3.54
3.66
3.44
ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Dimensions
Yes
No
No
No
No
No
280–340–400
515–625–735
613–744–875
613–744–875
788–956–1125
1040–1262–1485
Dry
CFM
Wet
CFM
—
—
—
—
—
—
Dry
CFM
280–340–400
515–625–735
613–744–875
613–744–875
788–956–1125
1040–1262–1485
Cooling
dB(A)
24–28–32
28–33–36
30–34–38
30–34–38
30–34–38
34–38–42
Heating
dB(A)
24–28–32
28–33–36
30–34–38
30–34–38
30–34–38
34–38–42
In. W.G.
0.3–0.5–0.8
0.3–0.5–0.8
0.3–0.5–0.8
0.3–0.5–0.8
0.3–0.5–0.8
0.3–0.5–0.8
External Static Pressure Condensate Lift Mechanism
Max Distance In. [mm]
—
—
—
—
—
—
50-1/4 [1275]
50-1/4 [1275]
54-1/4 [1378]
54-1/4 [1378]
59-1/2 [1511]
59-1/2 [1511]
H
In. [mm]
W
In. [mm]
17 [432]
17 [432]
21 [534]
21 [534]
25 [635]
25 [635]
D
In. [mm]
21-5/8 [548]
21-5/8 [548]
21-5/8 [548]
21-5/8 [548]
21-5/8 [548]
21-5/8 [548]
Weight
lbs [kg]
113 [51.2]
113 [51.2]
141 [64]
141 [64]
172 [78]
172 [78]
MCA
A
11.0
11.0
19.0
19.0
25.0
25.0
MOCP
A
28
28
26
26
31
31
37-1/8 [943]
37-1/8 [943]
52-11/16 [1338]
52-11/16 [1338]
Dimensions Outdoor Unit
H
In. [mm]
24-13/16 [630]
24-13/16 [630]
W
In. [mm]
31-13/16 (+7/16) [809 (+62)]
31-13/16 (+7/16) [809 (+62)]
37-13/32 [950]
37-13/32 [950]
41-5/16 [1050]
41-5/16 [1050]
11-3/16 [300]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
D Weight
lbs [kg]
Air Flow Rate (Cooling/Heating)
CFM
Sound Pressure Level
Diameter Piping
Electrical
Optional
Rated 1
Capacity at 5ºF
Indoor Unit
Optional
Capacity Range
Capacity at 17ºF
Efficiency
Optional
Capacity
Sensible Heat Factor
Heating
Optional
In. [mm]
11-3/16 [300] 93 [42]
100 [45]
153 [69]
153 [69]
214 [97]
214 [97]
1590/1590
1590/1590
1940/1940
1940/1940
3880/3880
3880/3880 52
Cooling
dB(A)
44
44
47
47
52
Heating
dB(A)
46
46
48
48
53
53
Gas (O.D.)
In. [mm]
1/2 [12.7]
1/2 [12.7]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
Liquid (O.D)
In. [mm]
1/4 [6.35]
1/4 [6.35]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
Indoor Drain
In. [mm]
3/4 FPT [19.05]
3/4 FPT [19.05]
3/4 FPT [19.05]
3/4 FPT [19.05]
3/4 FPT [19.05]
3/4 FPT [19.05] 165 [50]
Max. Length
ft [m]
100 [30]
100 [30]
165 [50]
165 [50]
165 [50]
Max. Height
ft [m]
100 [30]
100 [30]
100 [30]
100 [30]
100 [30]
100 [30]
Outdoor-Indoor 5
V, ph, Hz
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
Recommended Breaker Size A
Refrigerant Type Cooling 6 Guaranteed Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
ºF DB [ºC DB] ºF DB [ºC DB]
15
15
25
25
30
30
R410A
R410A
R410A
R410A
R410A
R410A
0.0 to 115.0 [-18.0 to 46.0] 12.0 to 70.0 [-11.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] 12.0 to 70.0 [-11.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -4.0 to 70.0 [-20.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -4.0 to 70.0 [-20.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -4.0 to 70.0 [-20.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -4.0 to 70.0 [-20.0 to 21.0]
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Wind baffles required to operate below 23°F DB in cooling mode. PUZ with wind baffle: 0° F - 115° F. Refer to wind baffle documentation for further information. SEACOAST PROTECTION • External Outer Panel: Phosphate coating + Acrylic-Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly; Valve Bed: Epoxy resin coating (at edge face) • “Blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. 1 2 3
93
60-140V/200/250
PVA Model
Optional
HYPER-HEATING
Interface Optional
Indoor Unit Outdoor Unit
Cooling
PVA-A24AA7
PVA-A30AA7
PVA-A36AA7
PVA-A42AA7
PUZ-HA24NHA
PUZ-HA30NHA5
PUZ-HA36NHA5
PUZ-HA42NKA
24,000
28,400
33,000
42,000
BTU/H
10,000–24,000
18,000
18,000
19,000
Power Input
Rated 1
W
2,100
2,280
2,640
4,270
Moisture Removal
Pints/h
3.7
8.0
7.9
9.0
0.830
0.700
0.740
0.760
Capacity at 47ºF
Rated 2
BTU/H
26,000
32,000
38,000
48,000
Capacity Range
Min-Max
BTU/H
10,000–28,000
18,000–34,000
18,000–40,000
18,000–54,000
Power Input at 47ºF
Rated 2
W
1,980
2,590
3,040
4,010
Rated 3
BTU/H
17,500
22,600
29,000
42,400
Max
BTU/H
26,000
32,000
38,000
48,000
Max 4
BTU/H
26,000
32,000
38,000
48,000
SEER
19.0
17.0
17.8
15.3
EER
11.5
12.5
12.5
9.8
HSPF
11
9.7
11
11
COP
3.7
3.62
3.66
3.14
Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Dimensions
No
Yes
Yes
No
613–744–875
613–744–875
788–956–1125
1040–1262–1485
Dry
CFM
Wet
CFM
—
—
—
—
Dry
CFM
613–744–875
613–744–875
788–956–1125
1040–1262–1485
Cooling
dB(A)
30–34–38
30–34–38
30–34–38
34–38–42
Heating
dB(A)
30–34–38
30–34–38
30–34–38
34–38–42
In. W.G.
0.3–0.5–0.8
0.3–0.5–0.8
0.3–0.5–0.8
0.3–0.5–0.8
External Static Pressure Condensate Lift Mechanism
Max Distance In. [mm]
—
—
—
—
54-1/4 [1378]
54-1/4 [1378]
59-1/2 [1511]
59-1/2 [1511]
H
In. [mm]
W
In. [mm]
21 [534]
21 [534]
25 [635]
25 [635]
D
In. [mm]
21-5/8 [548]
21-5/8 [548]
21-5/8 [548]
21-5/8 [548]
Weight
lbs [kg]
141 [64]
141 [64]
172 [78]
172 [78]
MCA
A
19.0
28.0
28.0
37.0
MOCP
A
26
40
40
44
37-1/8 [943]
53-1/8 [1375]
53-1/8 [1375]
52-11/16 [1338]
Dimensions
H
In. [mm]
W
In. [mm]
37-13/32 [950]
37-3/8 [950]
37-3/8 [950]
41-3/8 [1051]
D
In. [mm]
13 [+1-3/16] [330 [+30]]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
Weight
lbs [kg]
Air Flow Rate (Cooling/Heating)
CFM
Sound Pressure Level
Diameter Piping
85 [188]
265 [120]
265 [120]
287 [130]
1940/1940
3530/3530
3530/3530
3320/3320 49
Cooling
dB(A)
52
52
52
Heating
dB(A)
53
53
53
51
Gas (O.D.)
In. [mm]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
Liquid (O.D)
In. [mm]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
Indoor Drain
In. [mm]
3/4 FPT [19.05]
3/4 FPT [19.05]
3/4 FPT [19.05]
3/4 FPT [19.05]
Max. Length
ft [m]
165 [50]
245 [75]
245 [75]
245 [75]
Max. Height
ft [m]
100 [30]
100 [30]
100 [30]
100 [30]
Outdoor-Indoor 5
V, ph, Hz
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
25
30
30
40
R410A
R410A
R410A
R410A
0.0 to 115.0 [-18.0 to 46.0] -13.0 to 70.0 [-25.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -13.0 to 70.0 [-25.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -13.0 to 70.0 [-25.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -13.0 to 70.0 [-25.0 to 21.0]
Recommended Breaker Size A
Refrigerant Type Cooling 6 Guaranteed Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
ºF DB [ºC DB] ºF DB [ºC DB]
Cooling (Indoor // Outdoor) °F Heating at 47°F (Indoor // Outdoor) °F Heating at 17°F (Indoor // Outdoor) °F 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Wind baffles required to operate below 23°F DB in cooling mode. PUZ with wind baffle: 0° F - 115° F.
94
Optional
Optional
BTU/H
ENERGY STAR® Certified
Electrical
Optional
Rated 1
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi)
Outdoor Unit
Optional
Min-Max
Capacity at 5ºF
Indoor Unit
Optional
Capacity
Capacity at 17ºF
Efficiency
Optional
Capacity Range
Sensible Heat Factor
Heating
Optional
Wi-Fi
1 2 3
80 DB, 67 WB // 95 DB, 75 WB 70 DB, 60 WB // 47 DB, 43 WB 70 DB, 60 WB // 17 DB, 15 WB 70 DB, 60 WB // 5 DB, 4 WB
95
PEAD Model The thin, ceiling-concealed indoor units of this model are the perfect answer for the air conditioning needs of buildings with minimum ceiling installation space and wide-ranging external static pressure. Energy-saving efficiency has been improved, reducing electricity consumption and contributing to a further reduction in operating cost.
PEAD-A12/18/24/30/36/42AA7
Compact Indoor Units
External Static Pressure
The height is only 9-7/8" for all sizes of this model from 12 to 42 kBTU/H. This makes it possible for the unit to be installed in low ceilings with minimal clearance space.
External static pressure conversion can be set up to five settings. Capable of being set to a maximum of 0.60 In.W.G., units are applicable to a wide range of building types. ď Ž External static pressure Model
12
PEAD-A AA
18
24
30
36
42
0.14-0.20-0.28-0.40-0.60 In. W.G.
High Energy Efficiency SEER/HSPF has been greatly improved, and 12,000/18,000 BTU/H models have been added to the line-up. AA5 Series
SEER
AA7 Series
AA5 Series
HSPF
21.1 19.6
19.1
19.1
10.2 16.0
15.5
10.2
10.2 9.8
16.1 15.0
18
24
30
36
42
9.9
10.0 10.0
9.4
13.8
12
10.8
10.8 19.9
AA7 Series
12
18
24
30
36
42
Built-in Drain Lift Mechanism All models feature a built-in drain lift mechanism for removal of condensate. The unit’s fail-safe mechanism recognizes when there is a high liquid level in the condensate pan and turns off the indoor fan and the outdoor unit compressor to prevent overflow.
96
100-250
35-71
PEAD Model
JointL ap
Vector Sine Wave
DC Scroll
35-140
DC FanM otor
35-71
Grooved Piping
Vector-Wave
Heat Caulking Fixing Method
SERIES SELECTION Indoor Unit
Outdoor Unit
PEAD-A12/18/24/30/36/42AA7
Cooling Only
PUY-A12/18NKA7
PUY-A24/30NHA7
PUY-A36/42NKA7
Heat Pump
PUZ-A12/18NKA7
PUZ-A24/30NHA7
PUZ-A36/42NKA7
PUZ-HA24NHA
PUZ-HA30/36NHA5
Hyper-heating
PUZ-HA42NKA
Remote Controller
*optional PAR-40MAAU
*optional PAC-YT53CRAU-J
*optional
*optional PAR-CT01MAU-SB
*optional MHK2
97
60-140V/200/250
PEAD Model
Optional
Optional
COOLING ONLY
Interface Optional
Optional
Indoor Unit Outdoor Unit
Cooling
Optional
PEAD-A12AA7
PEAD-A18AA7
PEAD-A24AA7
PEAD-A30AA7
PEAD-A36AA7
PEAD-A42AA7
PUY-A18NKA7(-BS)
PUY-A24NHA7(-BS)
PUY-A30NHA7(-BS)
PUY-A36NKA7(-BS)
PUY-A42NKA7(-BS)
Rated 1
BTU/H
12,000
18,000
24,000
30,000
36,000
42,000
Min-Max
BTU/H
5,000–12,000
8,000–18,000
10,000–24,000
9,000–30,000
16,000–36,000
16,000–42,000
Power Input
Rated 1
W
920
1,660
2,050
3,000
3,000
3,920
Moisture Removal
Pints/h
1.8
3.7
6.9
8.6
8.1
9.0
0.830
0.770
0.680
0.680
0.750
0.760
Capacity at 47ºF
Rated
BTU/H
—
—
—
—
—
—
Capacity Range
Min-Max
BTU/H
—
—
—
—
—
—
Power Input at 47ºF
Rated
W
—
—
—
—
—
—
Rated
BTU/H
—
—
—
—
—
—
Max
BTU/H
—
—
—
—
—
—
Max
BTU/H
—
—
—
—
—
—
SEER
21.1
19.9
19.6
19.1
19.1
16.1
EER
13.0
10.8
11.7
10.0
12.0
10.7
HSPF
—
—
—
—
—
—
COP
—
—
—
—
—
—
Yes
No
No
No
No
No
ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Dry
CFM
353–424–494
424–512–600
512–636–742
618–742–883
847–1024–1201
1042–1254–1483
Wet
CFM
318–382–445
382–461–540
461–572–667
556–668–795
762–922–1081
1002–1214–1443
Dry
CFM
353–424–494
424–512–600
512–636–742
618–742–883
847–1024–1201
1042–1254–1483
Cooling
dB(A)
28–30–34
30–33–37
30–33–37
30–34–39
33–38–42
36–40–44
Heating
dB(A)
28–30–34
30–33–37
30–33–37
30–34–39
33–38–42
36–40–44
In. W.G.
0.14–0.2–0.28– 0.4–0.6
0.14–0.2–0.28– 0.4–0.6
0.14–0.2–0.28– 0.4–0.6
0.14–0.2–0.28– 0.4–0.6
0.14–0.2–0.28– 0.4–0.6
0.14–0.2–0.28– 0.4–0.6 27-9/16 [700]
External Static Pressure Condensate Lift Mechanism Dimensions
27-9/16 [700]
27-9/16 [700]
27-9/16 [700]
27-9/16 [700]
27-9/16 [700]
H
Max Distance In. [mm] In. [mm]
9-7/8 [250]
9-7/8 [250]
9-7/8 [250]
9-7/8 [250]
9-7/8 [250]
9-7/8 [250]
W
In. [mm]
35-7/16 [900]
35-7/16 [900]
43-5/16 [1100]
43-5/16 [1100]
55-1/8 [1400]
55-1/8 [1400]
D
In. [mm]
28-7/8 [732]
28-7/8 [732]
28-7/8 [732]
28-7/8 [732]
28-7/8 [732]
28-7/8 [732]
58 [26]
62 [28]
69 [31]
69 [31]
86 [39]
91 [41] 25.0
Weight
lbs [kg]
MCA
A
11.0
11.0
19.0
19.0
25.0
MOCP
A
28
28
26
26
31
31
37-1/8 [943]
37-1/8 [943]
52-11/16 [1338]
52-11/16 [1338]
Dimensions Outdoor Unit
H
In. [mm]
24-13/16 [630]
24-13/16 [630]
W
In. [mm]
31-13/16 (+7/16) [809 (+62)]
31-13/16 (+7/16) [809 (+62)]
37-13/32 [950]
37-13/32 [950]
41-5/16 [1050]
41-5/16 [1050]
D
In. [mm]
11-3/16 [300]
11-3/16 [300]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
Weight
lbs [kg]
92 [41]
99 [44]
151 [68]
151 [68]
211 [96]
211 [96]
Air Flow Rate (Cooling/Heating)
CFM
1590/—
1590/—
1940/—
1940/—
3880/—
3880/— 52
Sound Pressure Level
Diameter Piping
Electrical
Cooling
dB(A)
44
44
47
47
52
Heating
dB(A)
—
—
—
—
—
—
Gas (O.D.)
In. [mm]
1/2 [12.7]
1/2 [12.7]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
Liquid (O.D)
In. [mm]
1/4 [6.35]
1/4 [6.35]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
Indoor Drain
In. [mm]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32] 225 [68]
Max. Length
ft [m]
165 [50]
165 [50]
225 [68]
225 [68]
225 [68]
Max. Height
ft [m]
100 [30]
100 [30]
100 [30]
100 [30]
100 [30]
100 [30]
Outdoor-Indoor 5
V, ph, Hz
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
Recommended Breaker Size A
15
15
25
25
30
30
R410A
R410A
R410A
R410A
R410A
R410A
ºF DB [ºC DB]
-40.0 to 115.0 [-40.0 to 46.0]
-40.0 to 115.0 [-40.0 to 46.0]
-40.0 to 115.0 [-40.0 to 46.0]
-40.0 to 115.0 [-40.0 to 46.0]
-40.0 to 115.0 [-40.0 to 46.0]
-40.0 to 115.0 [-40.0 to 46.0]
ºF DB [ºC DB]
—
—
—
—
—
—
Refrigerant Type Guaranteed Cooling 6 Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
1
Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Wind baffles required to operate below 23°F DB in cooling mode. PUY with wind baffle: -40°F - 115°F. Refer to wind baffle documentation for further information. SEACOAST PROTECTION • External Outer Panel: Phosphate coating + Acrylic-Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly; Valve Bed: Epoxy resin coating (at edge face) • “Blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. 5
98
Optional
Capacity
Capacity at 5ºF
Indoor Unit
Optional
Capacity Range
Capacity at 17ºF
Efficiency
Optional
PUY-A12NKA7(-BS)
Sensible Heat Factor
Heating
Optional
Wi-Fi
Wi-Fi
PEAD Model
Interface Optional
HEAT PUMP
Optional
Indoor Unit Outdoor Unit
Cooling
Optional
Optional
Optional
PEAD-A12AA7
PEAD-A18AA7
PEAD-A24AA7
PEAD-A30AA7
PEAD-A36AA7
PEAD-A42AA7
PUZ-A12NKA7(-BS)
PUZ-A18NKA7(-BS)
PUZ-A24NHA7(-BS)
PUZ-A30NHA7(-BS)
PUZ-A36NKA7(-BS)
PUZ-A42NKA7(-BS)
BTU/H
12,000
18,000
24,000
30,000
36,000
42,000
Min-Max
BTU/H
5,000–12,000
8,000–18,000
10,000–24,000
9,000–30,000
16,000–36,000
16,000–42,000
Power Input
Rated 1
W
920
1,660
2,050
3,000
3,000
3,920
Moisture Removal
Pints/h
1.8
3.7
6.9
8.6
8.1
9.0
0.830
0.770
0.680
0.680
0.750
0.760
Capacity at 47ºF
Rated 2
BTU/H
14,000
19,000
26,000
32,000
38,000
45,000
Capacity Range
Min-Max
BTU/H
5,800–18,000
7,900–22,000
9,000–28,000
8,800–34,000
18,200–40,000
18,100–48,000
Power Input at 47ºF
Rated 2
W
1,030
1,400
1,750
2,490
2,410
3,290
Rated 3
BTU/H
8,700
11,000
14,800
18,500
20,800
30,600
Max
BTU/H
10,500
13,500
17,200
21,200
24,200
33,700
Max 4
BTU/H
—
—
—
—
—
—
SEER
21.1
19.9
19.6
19.1
19.1
16.1
EER
13.0
10.8
11.7
10.0
12.0
10.7
HSPF
10.2
10.2
10.8
10.8
9.9
10
COP
3.98
3.97
4.35
3.76
4.62
4.0
ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Yes
No
No
No
No
No
Dry
CFM
353–424–494
424–512–600
512–636–742
618–742–883
847–1024–1201
1042–1254–1483
Wet
CFM
318–382–445
382–461–540
461–572–667
556–668–795
762–922–1081
1002–1214–1443
Dry
CFM
353–424–494
424–512–600
512–636–742
618–742–883
847–1024–1201
1042–1254–1483
Cooling
dB(A)
28–30–34
30–33–37
30–33–37
30–34–39
33–38–42
36–40–44
Heating
dB(A)
28–30–34
30–33–37
30–33–37
30–34–39
33–38–42
36–40–44
In. W.G.
0.14–0.2–0.28– 0.4–0.6
0.14–0.2–0.28– 0.4–0.6
0.14–0.2–0.28– 0.4–0.6
0.14–0.2–0.28– 0.4–0.6
0.14–0.2–0.28– 0.4–0.6
0.14–0.2–0.28– 0.4–0.6 27-9/16 [700]
External Static Pressure Condensate Lift Mechanism Dimensions
27-9/16 [700]
27-9/16 [700]
27-9/16 [700]
27-9/16 [700]
27-9/16 [700]
H
Max Distance In. [mm] In. [mm]
9-7/8 [250]
9-7/8 [250]
9-7/8 [250]
9-7/8 [250]
9-7/8 [250]
9-7/8 [250]
W
In. [mm]
35-7/16 [900]
35-7/16 [900]
43-5/16 [1100]
43-5/16 [1100]
55-1/8 [1400]
55-1/8 [1400]
D
In. [mm]
28-7/8 [732]
28-7/8 [732]
28-7/8 [732]
28-7/8 [732]
28-7/8 [732]
28-7/8 [732]
58 [26]
62 [28]
69 [31]
69 [31]
86 [39]
91 [41] 25.0
Weight
lbs [kg]
MCA
A
11.0
11.0
19.0
19.0
25.0
MOCP
A
28
28
26
26
31
31
37-1/8 [943]
37-1/8 [943]
52-11/16 [1338]
52-11/16 [1338]
Dimensions Outdoor Unit
H
In. [mm]
24-13/16 [630]
24-13/16 [630]
W
In. [mm]
31-13/16 (+7/16) [809 (+62)]
31-13/16 (+7/16) [809 (+62)]
37-13/32 [950]
37-13/32 [950]
41-5/16 [1050]
41-5/16 [1050]
D
In. [mm]
11-3/16 [300]
11-3/16 [300]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
Weight
lbs [kg]
Air Flow Rate (Cooling/Heating)
CFM
Sound Pressure Level
Diameter Piping
Electrical
Optional
Rated 1
Capacity at 5ºF
Indoor Unit
Optional
Capacity Range
Capacity at 17ºF
Efficiency
Optional
Capacity
Sensible Heat Factor
Heating
Optional
93 [42]
100 [45]
153 [69]
153 [69]
214 [97]
214 [97]
1590/1590
1590/1590
1940/1940
1940/1940
3880/3880
3880/3880 52
Cooling
dB(A)
44
44
47
47
52
Heating
dB(A)
46
46
48
48
53
53
Gas (O.D.)
In. [mm]
1/2 [12.7]
1/2 [12.7]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
Liquid (O.D)
In. [mm]
1/4 [6.35]
1/4 [6.35]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
Indoor Drain
In. [mm]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32] 165 [50]
Max. Length
ft [m]
100 [30]
100 [30]
165 [50]
165 [50]
165 [50]
Max. Height
ft [m]
100 [30]
100 [30]
100 [30]
100 [30]
100 [30]
100 [30]
Outdoor-Indoor 5
V, ph, Hz
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
Recommended Breaker Size A
Refrigerant Type Cooling 6 Guaranteed Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
ºF DB [ºC DB] ºF DB [ºC DB]
15
15
25
25
30
30
R410A
R410A
R410A
R410A
R410A
R410A
0.0 to 115.0 [-18.0 to 46.0] 12.0 to 70.0 [-11.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] 12.0 to 70.0 [-11.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -4.0 to 70.0 [-20.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -4.0 to 70.0 [-20.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -4.0 to 70.0 [-20.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -4.0 to 70.0 [-20.0 to 21.0]
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Wind baffles required to operate below 23°F DB in cooling mode. PUZ with wind baffle: 0° F - 115° F. Refer to wind baffle documentation for further information. SEACOAST PROTECTION • External Outer Panel: Phosphate coating + Acrylic-Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly; Valve Bed: Epoxy resin coating (at edge face) • “Blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. 1 2 3
99
60-140V/200/250
PEAD Model
Optional
Optional
HYPER-HEATING
Optional
Optional
Interface Optional
Optional
PEAD-A24AA7
PEAD-A30AA7
PEAD-A36AA7
PEAD-A42AA7
Outdoor Unit
PUZ-HA24NHA
PUZ-HA30NHA5
PUZ-HA36NHA5
PUZ-HA42NKA
Capacity
Rated 1
BTU/H
24,000
27,000
33,000
42,000
Capacity Range
Min-Max
BTU/H
10,000–24,000
18,000
18,000
19,000
Power Input
Rated 1
W
2,080
2,160
2,640
4,200
Moisture Removal
Pints/h
6.9
8.9
7.3
9.0
0.680
0.670
0.760
0.760
Sensible Heat Factor
Heating
Capacity at 47ºF
Rated 2
BTU/H
25,000
32,000
38,000
48,000
Capacity Range
Min-Max
BTU/H
10,000–28,000
18,000–34,000
18,000–40,000
21,000–54,000
Power Input at 47ºF Capacity at 17ºF
Efficiency
2,750
3,150
3,800
19,000
27,000
43,000
BTU/H
25,000
32,000
38,000
48,000
25,000
32,000
38,000
48,000
SEER
16.6
16.5
16.8
14.3
EER
11.5
12.5
12.5
10.0
HSPF
11
9.5
10.4
10.8
COP
3.5
3.4
3.52
3.7
ENERGY STAR® Certified
No
Yes
Yes
No
847–1024–1201
1042–1254–1483
Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Dry
CFM
512–636–742
618–742–883
Wet
CFM
461–572–667
556–668–795
762–922–1081
1002–1214–1443
Dry
CFM
512–636–742
618–742–883
847–1024–1201
1042–1254–1483
Cooling
dB(A)
30–33–37
30–34–39
33–38–42
36–40–44
Heating
dB(A)
30–33–37
30–34–39
33–38–42
36–40–44
In. W.G.
0.14–0.2–0.28–0.4–0.6
0.14–0.2–0.28–0.4–0.6
0.14–0.2–0.28–0.4–0.6
0.14–0.2–0.28–0.4–0.6 27-9/16 [700]
External Static Pressure Condensate Lift Mechanism Dimensions
27-9/16 [700]
27-9/16 [700]
27-9/16 [700]
H
Max Distance In. [mm] In. [mm]
9-7/8 [250]
9-7/8 [250]
9-7/8 [250]
9-7/8 [250]
W
In. [mm]
43-5/16 [1100]
43-5/16 [1100]
55-1/8 [1400]
55-1/8 [1400]
D
In. [mm]
28-7/8 [732]
28-7/8 [732]
28-7/8 [732]
28-7/8 [732]
69 [31]
69 [31]
86 [39]
91 [41] 37.0
Weight
lbs [kg]
MCA
A
19.0
28.0
28.0
MOCP
A
26
40
40
44
37-1/8 [943]
53-1/8 [1375]
53-1/8 [1375]
52-11/16 [1338]
Dimensions
H
In. [mm]
W
In. [mm]
37-13/32 [950]
37-3/8 [950]
37-3/8 [950]
41-3/8 [1051]
D
In. [mm]
13 [+1-3/16] [330 [+30]]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
Weight
lbs [kg]
Air Flow Rate (Cooling/Heating)
CFM
Sound Pressure Level
Diameter Piping
Electrical
1,920 18,000
BTU/H
Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi)
Outdoor Unit
W BTU/H
Max 4
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi)
Indoor Unit
Rated 2 Rated 3 Max
Capacity at 5ºF
85 [188]
265 [120]
265 [120]
287 [130]
1940/1940
3530/3530
3530/3530
3320/3320 49
Cooling
dB(A)
52
52
52
Heating
dB(A)
53
53
53
51
Gas (O.D.)
In. [mm]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
Liquid (O.D)
In. [mm]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
Indoor Drain
In. [mm]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32]
Max. Length
ft [m]
165 [50]
245 [75]
245 [75]
245 [75]
Max. Height
ft [m]
100 [30]
100 [30]
100 [30]
100 [30]
Outdoor-Indoor 5
V, ph, Hz
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
25
30
30
40
R410A
R410A
R410A
R410A
0.0 to 115.0 [-18.0 to 46.0] -13.0 to 70.0 [-25.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -13.0 to 70.0 [-25.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -13.0 to 70.0 [-25.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -13.0 to 70.0 [-25.0 to 21.0]
Recommended Breaker Size A
Refrigerant Type Cooling 6 Guaranteed Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
Optional
Optional
Indoor Unit
Cooling
ºF DB [ºC DB] ºF DB [ºC DB]
Cooling (Indoor // Outdoor) °F Heating at 47°F (Indoor // Outdoor) °F Heating at 17°F (Indoor // Outdoor) °F 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Wind baffles required to operate below 23°F DB in cooling mode. PUZ with wind baffle: 0° F - 115° F.
100
Optional
Wi-Fi
1 2 3
80 DB, 67 WB // 95 DB, 75 WB 70 DB, 60 WB // 47 DB, 43 WB 70 DB, 60 WB // 17 DB, 15 WB 70 DB, 60 WB // 5 DB, 4 WB
101
PCA Model
PCA-A24/30/36/42KA7
A stylish new indoor unit design and airflow settings for both high and low ceiling interiors expand installation possibilities. Together with exceptional energy-saving performance, these units are the solution to diversified air conditioning needs.
Stylish Indoor Unit Design A stylish square-like design is adopted for the indoor units of all models. As a result, the units blend in better with the ceiling.
High Energy Efficiency SEER/HSPF has been greatly improved, realizing industry-leading energy-saving features. KA6 Series
SEER
KA7 Series
KA6 Series
HSPF
KA7 Series
21.2 19.6
10.9 10.8
19.1 17.6
16.8
10.0
15.8 14.5
24
14.4
30
10.2 10.2
36
42
9.2
36
42
Optional Drain Pump for All Models
24
30
Drain pump installation possible Drainage outlet can be 23-5/8 " above ceiling surface
The pumping height of the optional drain pump has been increased from 15-3/4" to 23-5/8", expanding flexibility in choosing unit location during installation work.
Ceiling surface
Equipped with Automatic Air-speed Adjustment
Equipped with High/Low-ceiling Modes
In addition to the conventional 4-speed setting, units are now equipped with an automatic air-speed adjustment mode. This setting automatically adjusts the air-speed to conditions that match the room environment. At the start of heating/cooling operation, the airflow is set to high-speed to quickly heat/cool the room. When the room temperature reaches the desired setting, the airflow speed is decreased automatically for stable comfortable heating/cooling operation.
Units are equipped with high- and low-ceiling operation modes that make it possible to switch the airflow volume to match room height. The ability to choose the optimum airflow volume ensures even temperature distribution throughout the room.
Strong
Start of cooling/heating
102
10.2 10.2
Gentle
After room temperature is stabilized
Capacity (kBTU/H)
High ceiling (ft)
Standard ceiling (ft)
Low ceiling (ft)
24
11.5
8.9
8.2
30
11.5
8.9
8.2
36
13.8
9.8
8.5
42
13.8
9.8
8.5
i-see Sensor™ (Optional)
Inlet temperature sensor
The i-see Sensor, an infrared sensor that detects floor temperature to improve the unevenness in room temperature. When cooling and heating, it also saves energy while keeping a comfortable effective temperature.
160°
Detection
i-see Sensor’s detecting area
8ft.
100-250
35-71
PCA Model
JointL ap
Vector Sine Wave
DC Scroll
35-140
DC FanM otor
35-71
Grooved Piping
Vector-Wave
Heat Caulking Fixing Method
MODEL SELECTION Indoor Unit
Outdoor Unit
Cooling Only
PUY-A24/30NHA7
PUY-A36/42NKA7
Heat Pump
PUZ-A24/30NHA7
PUZ-A36/42NKA7
PCA-A24/30/36/42KA7
Hyper-heating
PUZ-HA24NHA
PUZ-HA30/36NHA5
PUZ-HA42NKA
Remote Controller
*optional PAR-40MAAU
*optional PAC-YT53CRAU-J
*optional
*optional PAR-CT01MAU-SB
*optional MHK2
103
60-140V/200/250
PCA Model
Optional
Interface Optional
Indoor Unit Outdoor Unit
PCA-A30KA7
PCA-A36KA7
PCA-A42KA7
PUY-A30NHA7(-BS)
PUY-A36NKA7(-BS)
PUY-A42NKA7(-BS)
24,000
30,000
36,000
42,000
BTU/H
10,000–24,000
9,000–30,000
16,000–36,000
16,000–42,000
Power Input
Rated 1
W
1,960
3,190
3,270
4,110
Moisture Removal
Pints/h
5.8
8.3
8.7
11.7
0.730
0.690
0.730
0.690
Capacity at 47ºF
Rated
BTU/H
—
—
—
—
Capacity Range
Min-Max
BTU/H
—
—
—
—
Power Input at 47ºF
Rated
W
—
—
—
—
Rated
BTU/H
—
—
—
—
Max
BTU/H
—
—
—
—
Max
BTU/H
—
—
—
—
SEER
21.2
19.6
19.1
17.6
EER
12.2
9.4
11.0
10.2
HSPF
—
—
—
—
COP
—
—
—
—
ENERGY STAR® Certified
No
No
No
No 810–885–955–1025
Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Dry
CFM
530–565–600–670
565–600–635–705
775–850–920–990
Wet
CFM
495–530–565–635
530–565–600–670
705–775–850–920
740–810–885–955
Dry
CFM
530–565–600–670
565–600–635–705
775–850–920–990
810–885–955–1025
Cooling
dB(A)
33–35–37–40
35–37–39–41
37–39–41–43
39–41–43–45
Heating
dB(A)
33–35–37–40
35–37–39–41
37–39–41–43
39–41–43–45
In. W.G.
—
—
—
—
Max Distance In. [mm]
—
—
—
—
9-1/16 [230]
9-1/16 [230]
External Static Pressure Condensate Lift Mechanism Dimensions
H
In. [mm]
9-1/16 [230]
9-1/16 [230]
W
In. [mm]
50-3/8 [1280]
50-3/8 [1280]
63 [1600]
63 [1600]
D
In. [mm]
26-3/4 [680]
26-3/4 [680]
26-3/4 [680]
26-3/4 [680]
Weight
lbs [kg]
71 [32]
71 [32]
79 [36]
86 [39]
MCA
A
19.0
19.0
25.0
25.0
MOCP
A
26
26
31
31
37-1/8 [943]
37-1/8 [943]
52-11/16 [1338]
52-11/16 [1338]
Dimensions
H
In. [mm]
W
In. [mm]
37-13/32 [950]
37-13/32 [950]
41-5/16 [1050]
41-5/16 [1050]
D
In. [mm]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
Weight
lbs [kg]
151 [68]
151 [68]
211 [96]
211 [96]
Air Flow Rate (Cooling/Heating)
CFM
1940/—
1940/—
3880/—
3880/— 52
Sound Pressure Level
Diameter Piping
Electrical
PCA-A24KA7 PUY-A24NHA7(-BS) BTU/H
Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi)
Cooling
dB(A)
47
47
52
Heating
dB(A)
—
—
—
—
Gas (O.D.)
In. [mm]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
Liquid (O.D)
In. [mm]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
Indoor Drain
In. [mm]
1-1/32 [26]
1-1/32 [26]
1-1/32 [26]
1-1/32 [26]
Max. Length
ft [m]
225 [68]
225 [68]
225 [68]
225 [68]
Max. Height
ft [m]
100 [30]
100 [30]
100 [30]
100 [30]
Outdoor-Indoor 5
V, ph, Hz
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
25
25
30
30
R410A
R410A
R410A
R410A
ºF DB [ºC DB]
-40.0 to 115.0 [-40.0 to 46.0]
-40.0 to 115.0 [-40.0 to 46.0]
-40.0 to 115.0 [-40.0 to 46.0]
-40.0 to 115.0 [-40.0 to 46.0]
ºF DB [ºC DB]
—
—
—
—
Recommended Breaker Size A
Refrigerant Type Guaranteed Cooling 6 Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
1
Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Wind baffles required to operate below 23°F DB in cooling mode. PUY with wind baffle: -40°F - 115°F. Refer to wind baffle documentation for further information. SEACOAST PROTECTION • External Outer Panel: Phosphate coating + Acrylic-Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly; Valve Bed: Epoxy resin coating (at edge face) • “Blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. 5
104
Optional
Optional
Rated 1
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi)
Outdoor Unit
Optional
Min-Max
Capacity at 5ºF
Indoor Unit
Optional
Capacity
Capacity at 17ºF
Efficiency
Optional
Capacity Range
Sensible Heat Factor
Heating
Optional
Wi-Fi
COOLING ONLY
Cooling
Optional
Wi-Fi
PCA Model
Interface Optional
HEAT PUMP
Optional
Indoor Unit Outdoor Unit
Cooling
PCA-A30KA7
PCA-A36KA7
PCA-A42KA7
PUZ-A30NHA7(-BS)
PUZ-A36NKA7(-BS)
PUZ-A42NKA7(-BS)
24,000
30,000
36,000
42,000
BTU/H
10,000–24,000
9,000–30,000
16,000–36,000
16,000–42,000
Power Input
Rated 1
W
1,960
3,190
3,270
4,110
Moisture Removal
Pints/h
5.8
8.3
8.7
11.7
0.730
0.690
0.730
0.690
Capacity at 47ºF
Rated 2
BTU/H
26,000
32,000
38,000
45,000
Capacity Range
Min-Max
BTU/H
8,800–28,000
8,600–34,000
17,900–40,000
18,100–48,000
Rated 2
W
1,800
2,520
2,410
3,480
Rated 3
BTU/H
15,400
18,800
21,000
31,800
Max
BTU/H
17,900
21,600
24,400
35,000
Max 4
BTU/H
—
—
—
—
SEER
21.2
19.6
19.1
17.6
EER
12.2
9.4
11.0
10.2
HSPF
10.8
10
10.2
10.2
COP
4.23
3.72
4.62
3.78
No
No
No
No 810–885–955–1025
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Dry
CFM
530–565–600–670
565–600–635–705
775–850–920–990
Wet
CFM
495–530–565–635
530–565–600–670
705–775–850–920
740–810–885–955
Dry
CFM
530–565–600–670
565–600–635–705
775–850–920–990
810–885–955–1025
Cooling
dB(A)
33–35–37–40
35–37–39–41
37–39–41–43
39–41–43–45
Heating
dB(A)
33–35–37–40
35–37–39–41
37–39–41–43
39–41–43–45
In. W.G.
—
—
—
—
Max Distance In. [mm]
—
—
—
—
9-1/16 [230]
9-1/16 [230]
External Static Pressure Condensate Lift Mechanism Dimensions
H
In. [mm]
9-1/16 [230]
9-1/16 [230]
W
In. [mm]
50-3/8 [1280]
50-3/8 [1280]
63 [1600]
63 [1600]
D
In. [mm]
26-3/4 [680]
26-3/4 [680]
26-3/4 [680]
26-3/4 [680]
Weight
lbs [kg]
71 [32]
71 [32]
79 [36]
86 [39]
MCA
A
19.0
19.0
25.0
25.0
MOCP
A
26
26
31
31
37-1/8 [943]
37-1/8 [943]
52-11/16 [1338]
52-11/16 [1338]
Dimensions
H
In. [mm]
W
In. [mm]
37-13/32 [950]
37-13/32 [950]
41-5/16 [1050]
41-5/16 [1050]
D
In. [mm]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
Weight
lbs [kg]
Air Flow Rate (Cooling/Heating)
CFM
Sound Pressure Level
Diameter Piping
Electrical
PCA-A24KA7 PUZ-A24NHA7(-BS) BTU/H
Power Input at 47ºF
153 [69]
153 [69]
214 [97]
214 [97]
1940/1940
1940/1940
3880/3880
3880/3880 52
Cooling
dB(A)
47
47
52
Heating
dB(A)
48
48
53
53
Gas (O.D.)
In. [mm]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
Liquid (O.D)
In. [mm]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
Indoor Drain
In. [mm]
1-1/32 [26]
1-1/32 [26]
1-1/32 [26]
1-1/32 [26] 165 [50]
Max. Length
ft [m]
165 [50]
165 [50]
165 [50]
Max. Height
ft [m]
100 [30]
100 [30]
100 [30]
100 [30]
Outdoor-Indoor 5
V, ph, Hz
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
Recommended Breaker Size A
Refrigerant Type Cooling 6 Guaranteed Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
Optional
Optional
Rated 1
ENERGY STAR® Certified
Outdoor Unit
Optional
Optional
Min-Max
Capacity at 5ºF
Indoor Unit
Optional
Capacity
Capacity at 17ºF
Efficiency
Optional
Capacity Range
Sensible Heat Factor
Heating
Optional
ºF DB [ºC DB] ºF DB [ºC DB]
25
25
30
30
R410A
R410A
R410A
R410A
0.0 to 115.0 [-18.0 to 46.0] -4.0 to 70.0 [-20.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -4.0 to 70.0 [-20.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -4.0 to 70.0 [-20.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -4.0 to 70.0 [-20.0 to 21.0]
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Wind baffles required to operate below 23°F DB in cooling mode. PUZ with wind baffle: 0° F - 115° F. Refer to wind baffle documentation for further information. SEACOAST PROTECTION • External Outer Panel: Phosphate coating + Acrylic-Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly; Valve Bed: Epoxy resin coating (at edge face) • “Blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. 1 2 3
105
60-140V/200/250
PCA Model
Optional
HYPER-HEATING
Interface Optional
Indoor Unit Outdoor Unit
Cooling
PCA-A24KA7
PCA-A30KA7
PCA-A36KA7
PCA-A42KA7
PUZ-HA24NHA
PUZ-HA30NHA5
PUZ-HA36NHA5
PUZ-HA42NKA
24,000
30,000
34,000
42,000
BTU/H
10,000–24,000
18,000
18,000
19,000
Power Input
Rated 1
W
1,840
2,480
2,810
4,200
Moisture Removal
Pints/h
5.6
8.3
8.2
11.7
0.730
0.690
0.730
0.690
Capacity at 47ºF
Rated 2
BTU/H
26,000
32,000
38,000
48,000
Capacity Range
Min-Max
BTU/H
10,000–28,000
18,000–35,000
18,000–40,000
21,000–54,000
Power Input at 47ºF
Rated 2
W
2,050
2,990
3,270
4,150
Rated 3
BTU/H
17,700
19,000
27,000
44,000
Max
BTU/H
26,000
32,000
38,000
48,000
Max 4
BTU/H
26,000
32,000
38,000
48,000
SEER
18.5
16.1
16.6
14.5
EER
12.5
12.1
12.1
10.0
HSPF
10.8
9.3
10.3
10.4
COP
3.5
3.14
3.4
3.38
ENERGY STAR® Certified
Yes
No
No
No 810–885–955–1025
Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Dry
CFM
530–565–600–670
565–600–635–705
775–850–920–990
Wet
CFM
495–530–565–635
530–565–600–670
705–775–850–920
740–810–885–955
Dry
CFM
530–565–600–670
565–600–635–705
775–850–920–990
810–885–955–1025
Cooling
dB(A)
33–35–37–40
35–37–39–41
37–39–41–43
39–41–43–45
Heating
dB(A)
33–35–37–40
35–37–39–41
37–39–41–43
39–41–43–45
In. W.G.
—
—
—
—
Max Distance In. [mm]
—
—
—
—
9-1/16 [230]
9-1/16 [230]
External Static Pressure Condensate Lift Mechanism Dimensions
H
In. [mm]
9-1/16 [230]
9-1/16 [230]
W
In. [mm]
50-3/8 [1280]
50-3/8 [1280]
63 [1600]
63 [1600]
D
In. [mm]
26-3/4 [680]
26-3/4 [680]
26-3/4 [680]
26-3/4 [680]
Weight
lbs [kg]
71 [32]
71 [32]
79 [36]
86 [39]
MCA
A
19.0
28.0
28.0
37.0
MOCP
A
26
40
40
44
37-1/8 [943]
53-1/8 [1375]
53-1/8 [1375]
52-11/16 [1338]
Dimensions
H
In. [mm]
W
In. [mm]
37-13/32 [950]
37-3/8 [950]
37-3/8 [950]
41-3/8 [1051]
D
In. [mm]
13 [+1-3/16] [330 [+30]]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
13 (+1-3/16) [330 (+30)]
Weight
lbs [kg]
Air Flow Rate (Cooling/Heating)
CFM
Sound Pressure Level
Diameter Piping
85 [188]
265 [120]
265 [120]
287 [130]
1940/1940
3530/3530
3530/3530
3320/3320 49
Cooling
dB(A)
52
52
52
Heating
dB(A)
53
53
53
51
Gas (O.D.)
In. [mm]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
Liquid (O.D)
In. [mm]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
Indoor Drain
In. [mm]
1-1/32 [26]
1-1/32 [26]
1-1/32 [26]
1-1/32 [26]
Max. Length
ft [m]
165 [50]
245 [75]
245 [75]
245 [75]
Max. Height
ft [m]
100 [30]
100 [30]
100 [30]
100 [30]
Outdoor-Indoor 5
V, ph, Hz
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
25
30
30
40
R410A
R410A
R410A
R410A
0.0 to 115.0 [-18.0 to 46.0] -13.0 to 70.0 [-25.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -13.0 to 70.0 [-25.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -13.0 to 70.0 [-25.0 to 21.0]
0.0 to 115.0 [-18.0 to 46.0] -13.0 to 70.0 [-25.0 to 21.0]
Recommended Breaker Size A
Refrigerant Type Cooling 6 Guaranteed Temperature Operation Range Heating Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
ºF DB [ºC DB] ºF DB [ºC DB]
Cooling (Indoor // Outdoor) °F Heating at 47°F (Indoor // Outdoor) °F Heating at 17°F (Indoor // Outdoor) °F 4 Conditions Heating at 5°F (Indoor // Outdoor) °F 5 Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6 Wind baffles required to operate below 23°F DB in cooling mode. PUZ with wind baffle: 0° F - 115° F.
106
Optional
Optional
BTU/H
Air Flow Rate - Heating (Quiet-Lo-Med-Hi-SHi)
Electrical
Optional
Rated 1
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi)
Outdoor Unit
Optional
Min-Max
Capacity at 5ºF
Indoor Unit
Optional
Capacity
Capacity at 17ºF
Efficiency
Optional
Capacity Range
Sensible Heat Factor
Heating
Optional
Wi-Fi
1 2 3
80 DB, 67 WB // 95 DB, 75 WB 70 DB, 60 WB // 47 DB, 43 WB 70 DB, 60 WB // 17 DB, 15 WB 70 DB, 60 WB // 5 DB, 4 WB
107
MULTIZONE Models
108
SELECTION
Choose from six types of indoor units and thirteen outdoor units that can run up to eight indoor units each.
STEP 1
SELECT INDOOR UNIT Select the indoor unit to be installed in each room.
Wall Mounted
Floor Mounted
Multi-Position Air Handler
Ceiling Cassette
Ceiling Suspended
SLZ
MSZ-FH
PCA
Horizontal Ducted
PLA
MSZ-EF
MFZ-KJ
SEZ MLZ
SVZ MSZ-GL
PEAD
SELECT OUTDOOR UNIT
STEP 2
Select the best outdoor unit based on the number of indoor units and overall system capacity required. 3-port up to 3 indoor units
2-port up to 2 indoor units
MXZ-2C20NA2
MXZ-3C24NA2 MXZ-3C30NA2
4-port up to 4 indoor units
MXZ-4C36NA2
5-port up to 5 indoor units
8-port up to 8 indoor units
MXZ-5C42NA2
MXZ-8C48NA2 MXZ-8C60NA2
Hyper-heating 2-port up to 2 indoor units
3-port up to 3 indoor units
4-port up to 4 indoor units
5-port up to 5 indoor units
8-port up to 8 indoor units
MXZ-3C24NAHZ2 MXZ-3C30NAHZ2
MXZ-4C36NAHZ2
MXZ-5C42NAHZ2
MXZ-8C48NAHZ2
MXZ-2C20NAHZ2
STEP 3
CHECK SYSTEM COMPATIBILITY Possible combinations depends on the outdoor unit chosen. Please check the following points.
Check Indoor Units
Refer to the Indoor Unit Compatibility Table to check if the indoor units selected can be used with the outdoor unit selected. (Indoor units not listed in the table cannot be used.)
Check Indoor Unit Capacity Combination
Refer to the Combination Table to check if the capacity combination of the indoor unit selected is connectible. (Combinations not listed cannot be connected.)
If the desired combination cannot be found, please change either the indoor or outdoor unit to match one of the combinations shown in the tables.
109
MXZ Model
Outdoor Unit
Advancements in the MXZ-C Models include efficiency and flexibility in system expansion capabilities. The best solution when requiring multi-system air conditioning needs.
3-port
2-port MXZ-2C20NA2
4-port
MXZ-3C24NA2 MXZ-3C30NA2 MXZ-4C36NA2
5-port
8-port
MXZ-5C42NA2
MXZ-8C48NA2 MXZ-8C60NA2 8 Port Branch Box required
EXAMPLE SYSTEM
MXZ-8C48NA2 MXZ-8C60NA2
Smaller MXZ-C 2, 3, 4 and 5 ports (example of MXZ-5C42NA2 system)
MSZ-EF
MSZ-FH MSZ-EF
MSZ-GL
MSZ-GL
MSZ-FH
MLZ
MFZ-KJ
PAC-MKA32BC PAC-MKA52BC
MFZ-KJ
SLZ-KF MSDD-50AR-E or MSDD-50BR-E
SLZ-KF
PEAD
MXZ-5C42NA2
MXZ-8C60NA2
Refer to the multi-zone compatibility table on page 9.
SVZ
Handle Up to 8 Rooms with a Single Outdoor Unit The MXZ-C Model offers a seven-system line-up to choose from, ranging between 20,000 and 60,000 BTU/H. All of them are compatible with specific M- and P-Series indoor units. A single outdoor unit can handle a wide range of building layouts.
Optional Drain for All Models With MXZ-C Model one outdoor unit can cool and heat up to eight rooms. They can be installed neatly in sites with limited space such as condominium balconies.
Clean/neat installation
*Please note that cooling and heating modes cannot be run simultaneously in different rooms.
â– Single air conditioner
110
â– Multi air conditioner system
MXZ-C Model
2D-4E83
4E83-6D
3D-4D72
INVERTER MULTI
Up to 2 indoor units
Type Outdoor Unit
Capacity Cooling
Rated *1
MXZ-3C30NA2
MXZ-4C36NA2
MXZ-5C42NA2
MXZ-8C48NA2
No
No
No
No
Yes
Yes
R410A
R410A
R410A
R410A
R410A
R410A
R410A
1-phase, 60Hz, 208/230V
1-phase, 60Hz, 208/230V
1-phase, 60Hz, 208/230V
1-phase, 60Hz, 208/230V
1-phase, 60Hz, 208/230V
1-phase, 60Hz, 208/230V
1-phase, 60Hz, 208/230V
18,000
22,000
28,400
35,400
40,500
48,000
60,000
BTU/H
SEER
MXZ-8C60NA2
Refer to page 148
Capacity
Rated *1
BTU/H
22,000
25,000
28,600
36,000
45,000
54,000
66,000
Max at 17F *2
BTU/H
12,500
19,600
21,000
26,600
30,500
36,600
65,000
Max at 5F *3
BTU/H
11,100
18,200
18,200
24,000
26,000
32,400
57,000 46.0
HSPF
Outdoor Unit
Up to 8 indoor units
MXZ-3C24NA2
EER
Heating
Up to 5 indoor units
No
Source Outdoor (Phase, Hz, V)
Up to 4 indoor units
MXZ-2C20NA2
Branch Box Required Power Supply
Up to 3 indoor units
Refer to page 148
MCA
A
17.2
22.1
22.1
22.1
32.5
35.0
Recommended Fuse/Breaker Size
A
20
25
25
25
40
40
50
W
In. [mm]
33-1/16 [840]
37-13/32 [950]
37-13/32 [950]
37-13/32 [950]
37-13/32 [950]
41-11/32 [1,050]
41-11/32 [1,050]
D
In. [mm]
13 [330]
13 [330]
13 [330]
13 [330]
13 [330]
13+1 [330+25]
13+1 [330+25]
H
In. [mm]
27-15/16 [710]
31-11/32 [796]
31-11/32 [796]
31-11/32 [796]
41-17/64 [1,048]
52-11/16 [1,338]
52-11/16 [1,338]
Dimensions Weight
lbs [kg]
126 [57]
137 [62]
137 [62]
139 [63]
189 [86]
271 [123]
302 [137]
CFM
1,342/1,458
2,287/2,382
2,287/2,382
2,287/2,382
2,118/2,542
3,885
4,879
Cooling
dB [A]
50
51
52
54
56
51
58
Heating
dB [A]
54
55
56
56
58
54
59
Gas
In. [mm]
3/8 [9.52]
A: 1/2 [12.7] B,C: 3/8 [9.52]
A: 1/2 [12.7] B,C: 3/8 [9.52]
A: 1/2 [12.7] B,C,D: 3/8 [9.52]
A: 1/2 [12.7] B,C,D,E: 3/8 [9.52]
5/8 [15.88]
3/4 [19.05]
Liquid
In. [mm]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
3/8 [9.52]
3/8 [9.52]
ft [m]
164 [50]
230 [70]
230 [70]
230 [70]
262 [80]
492 [150]
492 [150]
Air volume (Cooling/Heating) Sound Level
Diameter Piping Max. Length Height
ft [m]
49 [15]
49 [15]
49 [15]
49 [15]
49 [15]
164 [50]
164 [50]
Cooling
F [C]
14 ~ 115°FDB [-10 ~ 46°CDB]
14 ~ 115°FDB [-10 ~ 46°CDB]
14 ~ 115°FDB [-10 ~ 46°CDB]
14 ~ 115°FDB [-10 ~ 46°CDB]
14 ~ 115°FDB [-10 ~ 46°CDB]
23 ~ 115°FDB [-5 ~ 46°CDB] *5
23 ~ 115°FDB [-5 ~ 46°CDB] *5
Heating
F [C]
5 ~ 75°FDB [-15 ~ 24°CDB]
5 ~ 75°FDB [-15 ~ 24°CDB]
5 ~ 75°FDB [-15 ~ 24°CDB]
5 ~ 75°FDB [-15 ~ 24°CDB]
5 ~ 75°FDB [-15 ~ 24°CDB]
-4 ~ 70°FDB [-20 ~ 21°CDB]
-4 ~ 70°FDB [-20 ~ 21°CDB]
Guaranteed Operation Range
NOTE: Test conditions are based on AHRI 210/240. *1 Rating Conditions (Cooling) - Indoor: 80° FDB, 67° FWB, Outdoor: 95° FDB, (75° FWB) (Heating) - Indoor: 70° FDB, 60° FWB, Outdoor: 47° FDB, 43° FWB *2 Rating Conditions (Heating) - Indoor: 70° FDB, 60° FWB, Outdoor: 17° FDB, 15° FWB *3 Rating Conditions (Heating) - Indoor: 70° FDB, 60° FWB, Outdoor: 5° FDB, 5° FWB *5 °F DB - 115°F DB when optional wind baffles are installed Type
Branch Box
Model Name Connectible Number of Indoor Units Power Supply
PAC-MKA52BC
Maximum 3
Maximum 5
1-phase, 60Hz, 208/230V 1-phase, 60Hz, 208/230V
Input
kW
0.003
A
0.05
0.05
W
In. [mm]
17-23/32 [450]
17-23/32 [450]
D
In. [mm]
11-1/32 [280]
11-1/32 [280]
H
In. [mm]
6-11/16 [170]
6-11/16 [170]
lbs [kg]
15 [6.7]
16 [7.4]
Gas
In. [mm]
3/8 [9.52] × 3
3/8 [9.52] × 4 1/2 [12.7] × 1
Running Current Dimensions Weight Piping Connection (Flare)
PAC-MKA32BC
Branch (indoor side)* Main (outdoor side)*
0.003
Liquid
In. [mm]
1/4 [6.35] × 3
1/4 [6.35] × 5
Gas
In. [mm]
5/8 [15.88]
5/8 [15.88]
Liquid
In. [mm]
3/8 [9.52]
3/8 [9.52]
*The piping connection size differs according to the type and capacity of indoor units. Match the piping connection size for indoor and branch box. If the piping connection size of branch box does not match the piping connection size of indoor units, use optional different-diameter (deformed) joints to the branch box side. (Connect deformed joint directly to the branch box side.)
111
MXZ-NAHZ Model New hyper-heating MXZ allows you to create an oasis of comfort throughout your home and office, in the rooms you use most, any time of the year.
Standard rated heating capacity is maintained even when the outside-air temperature drops to 5° F. Maintains high capacity output even when outside-air temperature is low. Hyper Heating
(MXZ-2C20NA2)
22,000 BTUH
22,000 BTUH
Our conventional model was not able to maintain standard rated heating capacity, making it hard to provide warming in case of low outside-air temperatures.
Falls
Maintained
12,500 BTUH
Provides standard rating (47° F) level heating capacity even with outside-air temperature of 5° F
Capacity decreased due to low outdoor-air temperature With outside temperature of 47° F
(standard rated heating capacity)
With outside temperature of 5° F
With outside temperature of 47° F
(standard rated heating capacity)
Can operate at outside-air temperature of –13° F 1. Incorporated key parts resistant to cold of up to –13° F after rigorous selection. 2. Printed circuit board is coated on both sides to protect it in harsh environments.
Base pan heater built-in Prevents capacity loss and operation from stopping due to drain water freezing. Drain water freezes after operation in the harsh cold
Without base heater
112
(MXZ-2C20NAHZ2)
Hyper-heating
Does not freeze
With base heater
With outside temperature of 5° F
Continuous heating for long periods Wasteful defrosting operation suppressed to enable more comfortable long-term continuous heating. Extremely cold outside
Hyper Heating
Outdoor Unit Branch Box Required Source Outdoor (Phase, Hz, V) Recommended Breaker Size Capacity Cooling
Rated *1
BTU/H
Up to 3 indoor units
Defrosting operation
Up to 4 indoor units
Up to 5 indoor units
Up to 8 indoor units MXZ-8C48NAHZ2
MXZ-3C24NAHZ2
MXZ-3C30NAHZ2
MXZ-4C36NAHZ2
MXZ-5C42NAHZ2
No
No
Yes
Yes
Yes
R410A
R410A
R410A
R410A
R410A
R410A
1-phase, 60Hz, 208/230V
1-phase, 60Hz, 208/230V
1-phase, 60Hz, 208/230V
1-phase, 60Hz, 208/230V
1-phase, 60Hz, 208/230V
1-phase, 60Hz, 208/230V
42,000
48,000
40
40
40
50
18,000
22,000
28,400
36,000 Refer to page 148
Rated *1
BTU/H
22,000
25,000
28,600
45,000
48,000
54,000
Max at 17F *2
BTU/H
22,000
25,000
28,600
45,000
48,000
54,000
Max at 5F *3
BTU/H
22,000
25,000
28,600
45,000
48,000
54,000
HSPF
Outdoor Unit
Heating operation
No
SEER
Capacity
Heating operation
MXZ-2C20NAHZ2
EER
Heating
Defrosting operation
Heating operation
Up to 2 indoor units
Type
Power Supply
The unit may enter defrosting mode under certain environmental conditions, such as if outside-air humidity increases.
MXZ-C-NAHZ Model
MXZ-C-NA Model
Defrosting operation
Comfort using long-term heating mode
During defrosting operation, the unit stops and is cold…
Refer to page 148
MCA
A
29.5
30.5
30.5
42
42
42
Recommended breaker/fuse size
A
40
40
50
45
45
45 41-11/32 [1,050]
Dimensions
W
In. [mm]
37-13/32 [950]
37-13/32 [950]
41-11/32 [1,050]
41-11/32 [1,050]
41-11/32 [1,050]
D
In. [mm]
13 [330]
13 [330]
13 [330]
13+1 [330+25]
13+1 [330+25]
13+1 [330+25]
H
In. [mm]
41-17/64 [1,048]
41-17/64 [1,048]
41-17/64 [1,048]
52-11/16 [1,338]
52-11/16 [1,338]
52-11/16 [1,338]
Weight
lbs [kg]
187 [85]
189 [86]
189 [86]
278 [126]
278 [126]
278 [126]
CFM
2,118/2,542
2,188/2,542
2,224/2,542
3,885
3,885
3,885
Cooling
dB [A]
54
54
54
49
50
51
Heating
dB [A]
58
58
58
53
54
54
Gas
In. [mm]
3/8 [9.52]
A: 1/2 [12.7] B,C: 3/8 [9.52]
A: 1/2 [12.7] B,C: 3/8 [9.52]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
Liquid
In. [mm]
1/4 (6.35)
1/4 (6.35)
1/4 (6.35)
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
ft [m]
164 [50]
230 [70]
230 [70]
492 [150]
492 [150]
492 [150]
Air volume (Cooling/Heating) Sound Level
Diameter Piping Max. Length Height Guaranteed Operation Range
ft [m]
49 [15]
49 [15]
49 [15]
164 [50]
164 [50]
164 [50]
Cooling
F [C]
14 ~ 115°FDB [-10 ~ 46°CDB]
14 ~ 115°FDB [-10 ~ 46°CDB]
14 ~ 115°FDB [-10 ~ 46°CDB]
23 ~ 115°FDB [-5 ~ 46°CDB] *5
23 ~ 115°FDB [-5 ~ 46°CDB] *5
23 ~ 115°FDB [-5 ~ 46°CDB] *5
Heating
F [C]
-13 ~ 75°FDB [-25 ~ 24°CDB]
-13 ~ 75°FDB [-25 ~ 24°CDB]
-13 ~ 75°FDB [-25 ~ 24°CDB]
-13 ~ 70°FDB [-25 ~ 21°CDB]
-13 ~ 70°FDB [-25 ~ 21°CDB]
-13 ~ 70°FDB [-25 ~ 21°CDB]
NOTE: Test conditions are based on AHRI 210/240. *1 Rating Conditions (Cooling) - Indoor: 80° FDB, 67° FWB, Outdoor: 95° FDB, (75° FWB) (Heating) - Indoor: 70° FDB, 60° FWB, Outdoor: 47° FDB, 43° FWB *2 Rating Conditions (Heating) - Indoor: 70° FDB, 60° FWB, Outdoor: 17° FDB, 15° FWB *3 Rating Conditions (Heating) - Indoor: 70° FDB, 60° FWB, Outdoor: 5° FDB, 5° FWB *5 °F DB - 115°F DB when optional wind baffles are installed
113
Indoor Unit Compatibility Table MXZ Model *1
Possible combinations of outdoor units and indoor units are shown below. Outdoor Unit
Indoor Unit
MSZ-FH06NA MSZ-FH09NA MSZ-FH12NA MSZ-FH15NA
MXZ-2C20NA2
MXZ-3C24NA2
MXZ-3C30NA2
MXZ-4C36NA2
MXZ-5C42NA2
MXZ-8C48NA2
MXZ-8C60NA2
• • • •
• • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • • •*2 •*2 •*2
• • • • • • • • • • • • • • • • • • • • • • •*2 •*2 •*2
• • • • • • • • • • • • • • • • • • • • • • •*2 •*2 •*2
• • • • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • •
• • • • • • •
• • • • • • •
• • • • • • •
• • • • • • •
•
•
•
•
•
•
•
•*3 •*3 •
•*3 •*3 •
•*3 •*3 •*3
MSZ-FH18NA2 MSZ-GL06NA MSZ-GL09NA Wall Mounted
MSZ-GL12NA MSZ-GL15NA
• • • •
MSZ-GL18NA MSZ-GL24NA MSZ-EF09NAW(S)(B) MSZ-EF12NAW(S)(B) MSZ-EF15NAW(S)(B)
• • •
MSZ-EF18NAW(S)(B) MFZ-KJ09NA M-Series
Floor Standing
MFZ-KJ12NA MFZ-KJ15NA
• • •
MFZ-KJ18NA EZ FIT™ Recessed Ceiling Cassette
MLZ-KP09NA MLZ-KP12NA MLZ-KP18NA SVZ-KP12NA
• • • •*2
SVZ-KP18NA Multi-position Air Handler
• • • • • • • • • • • •*2 •*2
SVZ-KP24NA SVZ-KP30NA SVZ-KP36NA SLZ-KF09NA
4-way Cassette
SLZ-KF12NA
• •
SLZ-KF15NA SEZ-KD09NA4 Horizontal-ducted
SEZ-KD12NA4 SEZ-KD15NA4
• • •
SEZ-KD18NA4 PLA-A12EA7 PLA-A18EA7 4-way Cassette
PLA-A24EA7 PLA-A30EA7 PLA-A36EA7
•*3, 4 •*3, 4 •*3, 4 •*3, 4 •*3, 4 • • • •*6 •*6 •*6 •*6 •*5 •*5 •*5 •*5 •*5
•*3, 4 •*3, 4 •*3, 4 •*3, 4 •*3, 4 • • • •*7 •*7 •*7 •*7 •*5 •*5 •*5 •*5 •*5
•*6 •*6 •*6 •*6 •*6
•*7 •*7 •*7 •*7 •*7
PLA-A42EA7 PCA-A24KA7 P-Series
Ceiling Suspended
PCA-A30KA7 PCA-A36KA7 PCA-A42KA7 PEAD-A12AA7 PEAD-A18AA7
Horizontal-ducted
PEAD-A24AA7 PEAD-A30AA7 PEAD-A36AA7
•*3
•*3 •
PEAD-A42AA7 Information is current as of this printing. Minimum installed capacity cannot be less than 12,000 BTU/H. A minimum of two indoor units must be connected to all MXZ-C outdoor units. *2 Only one SVZ Model can be connected. *3 Maximum of two units can be connected unless the SPTB1 is utilized to power the indoor unit. *4 Single unit can be connected. *5 When the system includes even 1 unit of PLA-A·EA7, the number of the maximum connectable indoor units is decreased as follows: 3 for MXZ-4C36NAHZ, 4 for MXZ-5C42NAHZ, and 6 for MXZ-8C48NA(HZ) and MXZ-8C60NA. *6 Maximum of 3 horizontal ducted indoor units (PEAD or SEZ) can be connected. *7 Maximum of 2 horizontal ducted indoor units (PEAD or SEZ) can be connected. For more information, please refer to the service manual, application 1029 and the full compatibility chart on mylinkdrive.
114
MXZ-NAHZ Model *1
Possible combinations of outdoor units and indoor units are shown below. Outdoor Unit
Indoor Unit
MSZ-FH06NA MSZ-FH09NA MSZ-FH12NA MSZ-FH15NA
MXZ-2C20NAHZ2
MXZ-3C24NAHZ2
MXZ-3C30NAHZ2
MXZ-4C36NAHZ2
MXZ-5C42NAHZ2
MXZ-8C48NAHZ2
• • • •
• • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • • •*2 •*2 •*2
• • • • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • •
MSZ-FH18NA2 MSZ-GL06NA MSZ-GL09NA Wall Mounted
MSZ-GL12NA MSZ-GL15NA
• • • •
MSZ-GL18NA MSZ-GL24NA MSZ-EF09NAW(S)(B) MSZ-EF12NAW(S)(B) MSZ-EF15NAW(S)(B)
• • •
MSZ-EF18NAW(S)(B) MFZ-KJ09NA M-Series
Floor Standing
MFZ-KJ12NA MFZ-KJ15NA
• • •
MFZ-KJ18NA EZ FIT™ Recessed Ceiling Cassette
MLZ-KP09NA MLZ-KP12NA MLZ-KP18NA SVZ-KP12NA
• • • •*2
SVZ-KP18NA Multi-position Air Handler
• • • • • • • • • • • •*2 •*2
SVZ-KP24NA SVZ-KP30NA SVZ-KP36NA SLZ-KF09NA
4-way Cassette
SLZ-KF12NA
• •
SLZ-KF15NA SEZ-KD09NA4 Horizontal-ducted
SEZ-KD12NA4 SEZ-KD15NA4
• • •
SEZ-KD18NA4
• • • • • • •
• • • • • • •
•
•
PLA-A12EA7 PLA-A18EA7 4-way Cassette
PLA-A24EA7 PLA-A30EA7 PLA-A36EA7
•*3, 4 •*3, 4 •*3, 4 •*3, 4 •*3, 4 • • • •*6 •*6 •*6 •*6 •*5 •*5 •*5 •*5 •*5
•*3, 4 •*3, 4 •*3, 4 •*3, 4 •*3, 4 • • • •*6 •*6 •*6 •*6 •*5 •*5 •*5 •*5 •*5
•*3, 4 •*3, 4 •*3, 4 •*3, 4 •*3, 4 • • • •*6 •*6 •*6 •*6 •*5 •*5 •*5 •*5 •*5
•*6 •*6 •*6 •*6 •*6
•*6 •*6 •*6 •*6 •*6
•*6 •*6 •*6 •*6 •*6
PLA-A42EA7
•
PCA-A24KA7 P-Series
Ceiling Suspended
PCA-A30KA7 PCA-A36KA7 PCA-A42KA7 PEAD-A12AA7 PEAD-A18AA7
Horizontal-ducted
PEAD-A24AA7 PEAD-A30AA7 PEAD-A36AA7
•*3
•*3 •
•*3 •*3 •
PEAD-A42AA7 Information is current as of this printing. Minimum installed capacity cannot be less than 12,000 BTU/H. A minimum of two indoor units must be connected to all MXZ-C outdoor units. *2 Only one SVZ Model can be connected. *3 Maximum of two units can be connected unless the SPTB1 is utilized to power the indoor unit. *4 Single unit can be connected. *5 When the system includes even 1 unit of PLA-A·EA7, the number of the maximum connectable indoor units is decreased as follows: 3 for MXZ-4C36NAHZ, 4 for MXZ-5C42NAHZ, and 6 for MXZ-8C48NA(HZ) and MXZ-8C60NA. *6 Maximum of 3 horizontal ducted indoor units (PEAD or SEZ) can be connected. *7 Maximum of 2 horizontal ducted indoor units (PEAD or SEZ) can be connected. For more information, please refer to the service manual, application 1029 and the full compatibility chart on mylinkdrive.
115
Conditions for Specifications Temperature conditions are based on AHRI 210/240. Cooling
Heating
Indoor
D.B. 80º F (27º C), W.B. 67º F (19º C)
Outdoor
D.B. 95º F (35º C), W.B. 75º F (24º C)
Indoor
D.B. 70º F (21º C), W.B. 60º F (16º C)
Outdoor
D.B. 17º F (-8º C), W.B. 15º F (-9º C)
Refrigerant piping length: 16 ft. The figures for total input are based on the following voltages. Series
Indoor unit
Outdoor unit
-
208 / 230V • Single phase • 60Hz
M Series P Series MXZ-C Model
Sound pressure level • The sound pressure measurement is conducted in an anechoic chamber. • The actual sound level depends on the distance from the unit and the acoustic environment.
How to Read a Model Name 1) M-Series M S Z E F 12 N A W
Series Generation Rated cooling capacity (KBTU/H base) 208 / 230V • Single phase • 60Hz A= R410A with new A control HZ= Hyper Heating model, H= Anti -freeze heater equipped model/base heater, S= Silver indoor unit, W= White indoor unit, B= Black indoor unit
2) P-Series P
U Z A 18 N K A 7
MSZ-EF12NAW
M or S: M-Series S= Wall-mounted, F= Compact floor-standing, E= Compact ceiling-concealed, L= 4- or 1-way cassette, U= Outdoor unit Z= Inverter heat pump, H= Fixed-speed heat pump, Y= Cooling only
PUZ-A18NKA
P Series K= Wall-mounted, S= Floor-standing, L= 4 -way cassette, E= Ceiling-concealed, C= Ceiling-suspended, U= Outdoor unit Z= For heating and cooling, Y= Cooling only A=Standard HA=Hyper heating Rated cooling capacity (KBTU/H base) 208 / 230V • Single phase • 60Hz Generation A= A control 7= Generation
3) MXZ-C Model
116
MXZ-4C36NAHZ
M X Z
M Series Multi-system outdoor unit (heat pump) Inverter heat pump
4 C 36 N A HZ
Maximum number of connectable indoor units Generation Rated cooling capacity (KBTU/H base) 208 / 230V • Single phase • 60Hz A= R410A with new A control HZ= Hyper Heating model
Piping Installation M-Series Single type
Series
MUZ-FH
MUZ/MUY-GL
MUZ/MUY-HM
MUFZ-KJ
SUZ-KA-NA2/NAHZ
Maximum Piping Length (ft)
Maximum Height Difference (ft)
Maximum Number of Bends
Total length (A)
Outdoor unit - Indoor unit (H)
Total number
06/09/12
65
40
10
15/18
100
50
10
09/12/15
65
40
10
18/24
100
50
10
09/12/15/18
65
40
10
24
100
50
10
09/12
65
40
10
15/18
100
50
10
09/12/15
65
40
10
18
100
50
10
24/30/36
100
100
10
Maximum Piping Length (ft)
Maximum Height Difference (ft)
Maximum Number of Bends
Total length (A)
Outdoor unit - Indoor unit (H)
Total number
Class <Outdoor unit>
P-Series Single type Series
PUY
PUZ
PUZ-HA
Class < Outdoor unit> 12/18
165
24/30/36/42
225
12/18
100
24/30/36/42
165
24/30/36/42
245
100
100 100
15 15 15 15 15
117
MXZ Model MXZ-2C20NA2
Maximum Piping Length
Outdoor unit - Indoor unit (a,b)
Total length (a+b)
Indoor units
b
164 ft.
Outdoor unit
Maximum Number of Bends Outdoor unit - Indoor unit (a,b) Total number (a+b)
Max. height difference
82 ft.
25
49 ft.
50 33 ft.
a
MXZ-2C20NAHZ2
Maximum Piping Length
Outdoor unit - Indoor unit (a,b)
Total length (a+b)
Indoor units
b
Total number (a+b)
Max. height difference
82 ft.
164 ft.
Outdoor unit
Maximum Number of Bends Outdoor unit - Indoor unit (a,b)
49 ft.
50
MXZ-3C24NA2, MXZ-3C30NA2, MXZ-3C24NAHZ2, MXZ-3C30NAHZ2 Outdoor unit - Indoor unit (a,b,c)
Total length (a+b+c)
Indoor units
49 ft.
c
Total number (a+b+c)
230 ft. b
Outdoor unit
49 ft.
25
49 ft.
70 a
118
Max. height difference
82 ft.
Maximum Number of Bends Outdoor unit - Indoor unit (a,b,c)
49 ft.
25
a
Maximum Piping Length
49 ft.
49 ft.
MXZ-4C36NA2
Maximum Piping Length
Outdoor unit - Indoor unit (a,b,c,d)
Total length (a+b+c+d)
Maximum Number of Bends Outdoor unit - Indoor unit (a,b,c,d) Total number (a+b+c+d)
Indoor units
d Max. height difference
82 ft.
230 ft.
c
25
Outdoor unit
49 ft.
b
70
49 ft.
a
MXZ-5C42NA2
Indoor units
Maximum Piping Length
Outdoor unit - Indoor unit (a,b,c,d,e)
Total length (a+b+c+d+e)
Maximum Number of Bends
Outdoor unit - Indoor unit (a,b,c,d,e) Total number (a+b+c+d+e)
49 ft.
e Max. height difference
82 ft.
262 ft.
d
25
c
Outdoor unit
49 ft.
80
49 ft.
b
a
49 ft.
119
MXZ Model MXZ-4C36NAHZ2, MXZ-5C42NAHZ2, MXZ-8C48NAHZ2, MXZ-8C48NA2, MXZ-8C60NA2 A B C D
L
c1
D
b2
b1
B H
Outdoor unit Branch box Indoor unit
h2
a1
h1
a2 h3
C
a3
C
a4
C
I
a5
C
B
a6
C
a7 a8
C C
Permissible length (one-way)
Total piping length Farthest piping length (L) *1 Piping length between outdoor unit and branch boxes Farthest piping length after branch box (l) Total piping length between branch boxes and indoor units
In indoor/outdoor section (H) *2 Permissible height difference In branch box/indoor unit section (h1) (one-way) In each branch unit (h2) In each indoor unit (h3) Number of bends
c1 + b1 + b2 + a1 + a2 + a3 + a4 + a5 + a6 + a7 + a8 ≤ 150 m (492 ft.) c1 + b2 + a8 ≤ 80 m (262 ft.) c1 + b1 + b2 ≤ 55 m (180 ft.) b2 ≤ 30 m (98 ft.) a8 ≤ 25 m (82 ft.) a1 + a2 + a3 + a4 + a5 + a6 + a7 + a8 ≤ 95 m (311 ft.) H ≤ 50 m (164 ft.) (In case of outdoor unit is set higher than indoor unit) H ≤ 40 m (131 ft.) (In case of outdoor unit is set lower than indoor unit) h1 + h2 ≤ 15 m (49 ft.) h2 ≤ 15 m (49 ft.) h3 ≤ 12 m (39 ft.) | c1 + b1 + a1 |, | c1 + b1 + a2 |, | c1 + b1 + a3 |, | c1 + b1 + a4 |, | c1 + b1 + a5 |, | c1 + b2 + a6 |, | c1 + b2 + a7 |, | c1 + b2 + a8 | ≤ 15
*1 The tent noise during normal system operation in very quiet environments. Please be aware of this important information when installing and locating the indoor unit within the conditioned space. *2 Branch box should be placed within the level between the outdoor unit and indoor units.
120
Explanation of Terminology Maximum piping length:
This is the maximum allowable length of the refrigerant piping. The amount of refrigerant pipe used cannot be longer than the length specified.
► Total length:
The maximum allowable combined length of all the refrigerant piping between the outdoor unit and indoor unit(s).
► Outdoor Unit - Indoor Unit:
The maximum allowable length of the refrigerant piping between the outdoor unit and indoor units installed when multiple units are connected to a single outdoor unit. This distance limitation refers to the maximum length between the outdoor unit and the farthest indoor unit.
► Pipe length difference from distribution pipe:
The maximum allowable difference in refrigerant piping length from the distribution pipe to the farthest indoor unit and from the distribution pipe to the closest indoor unit when multiple indoor units are connected to a single outdoor unit using a distribution pipe.
► Indoor Unit - Distribution Pipe:
The maximum allowable length of the refrigerant piping between indoor units and the distribution pipe when multiple indoor units are connected to a single outdoor unit.
Maximum height difference:
This is the maximum allowable height difference. It is necessary to install the air conditioning system so that the height distance is no more than the difference specified. (Specified differences may vary if the outdoor unit is installed higher or lower than the indoor units).
► Outdoor unit - Indoor unit:
The maximum allowable difference in height between the outdoor unit and indoor units when installed (when multiple indoor units are connected to a single outdoor unit, this distance limitation refers to the maximum height difference between the outdoor unit and an indoor unit).
► Indoor unit - Indoor unit:
The maximum allowable difference between the heights of indoor units when multiple indoor units are connected to a single outdoor unit.
Maximum number of bends:
This is the maximum allowable number of bends in the refrigerant piping. The total number of bends in the refrigerant piping used cannot exceed the number specified.
► Total number:
The maximum allowable number of bends for all refrigerant piping between the outdoor unit and indoor units.
► Outdoor unit - Indoor unit:
The maximum allowable number of bends between the outdoor unit and each indoor unit when multiple indoor units are connected to a single outdoor unit.
121
To ensure full capacity in cold and snowy regions...
3 Important Points to Remember When Installing the Outdoor Unit Wind and snow can significantly reduce capacity. Be sure to check the information below and install the outdoor unit correctly.
1
Installation Location
Be aware of the prevailing wind direction in winter and install the outdoor unit where it is as sheltered as possible.
2
Units are easily affected by wind and unit may not be able to run at full capacity
Less influence of wind and unit runs at full capacity
Measures for Drainage of Water
Case 1: Unit is installed close to passage (walkway)
Do not install the unit close to passage as drainage water from the unit may freeze and cause a slipping hazard. Correct installation
Wrong installation Drainage water splashes on pedestrians.
Wrong installation Unit may freeze and become damaged because water will not be drained from the drain hole.
Note
Install at a sufficient height from the ground to prevent problems caused by frozen drainage water. Install in a location where frozen drainage water will not be a hazard. Install in an upright position to allow proper drainage from the drainage outlet.
Case 2: Multiple units are installed
Do not install units on top of one another as it may cause frozen drainage water on the bottom unit.
Frozen drainage water may cause a slipping hazard.
Correct installation Note
Place units side by side.
122
Wrong installation Bottom unit may freeze.
3
Measures for Snow
Do not install the unit on the ground
To avoid the adverse effects of snow and frozen drainage water, install the unit on a stand to ensure a sufficient height from the ground. Correct installation
Wrong installation
Note
Install at a position/height to prevent the unit being buried in snow *1 and the adverse effects of frozen drainage water.*2 Install so as to avoid the effects of snow or snowdrift. Install so as to avoid the damage from falling snow or icicles. *1 Install at a height above the highest snowfall depth.
Wrong installation
Unit may become buried in snow due to heavy snowfall, snow sliding off the roof or snowdrift.
*2 Even for correct installations, dripping drainage water
may form an icicle which needs to be cleared away regularly to prevent a blocked drainage outlet.
Install snow protection hood as necessary
Use a stand to add sufficient height to protect the unit heat exchanger from snow and prevent icicles forming during defrost operation. Correct installation Minimum height (h) should be higher than the highest snowfall depth (h0)
+7.8 in.
Wrong installation
Air exhaust snow hood
Unit may become covered in snow if the stand height is insufficient.
Air intake snow hood (rear)
Air intake snow hood (side panel)
h
h0
Stand height h
Unit may be damaged due to snowfall or icicles.
Correct installation Without hood
Note
Install the snow protection hood or other cover in snowy regions.
Snowfall height h0 Stand is too low.
Recommended accessories (drain socket & centralized drain pan, stand, snow protection hood, base heater) Snowy region
Cold region
Countermeasures for snow
Countermeasures for freezing
Not used
Not used
Prevents freezing
Needed
1. Install so as to prevent the unit being buried in snow (at a height greater than the highest snowfall depth). Be sure that the stand does not obstruct drainage. 2. Install so as to prevent damage to the unit due to frozen drainage water (icicles).
Drain socket, Centralized drain pan
Needed
Stand
Needed
Snow protection hood
*When the installation position is subject to snowfall.
—
—
Needed
Base heater
CAUTION
Remarks
Clearance to prevent snow accumulating.
<Correct>
1. Prevents heat exchanger from being covered in snow. 2. Prevents snow accumulating inside the air duct. Outdoor units equipped with a heater for cold regions are those with an“H” in the model name. For the cold-climate zone, use of a unit with a heater is strongly recommended. Even for the moderate-climate zone use of a unit with a heater is recommended for regions subject to high humidity in winter.
About disposal of drainage water When the unit is installed in cold or snowy regions :
Drainage water may freeze in the drain socket/hose and prevent the fan from rotating.
Do not attach a drain socket packaged as an accessory to the unit.
✽ In the case that fitting a drain socket is absolutely necessary, steps must be taken so that the drainage water does not freeze. For more information, please consult Mitsubishi Electric Trane HVAC US or one of its dealers/resellers.
Arrangement for snow protection hood
Separately sold parts are available for some models. Please consult Mitsubishi Electric Trane HVAC US or one of its dealers/resellers at the time of purchase for details.
123
System Control Versatile system controls can be achieved by using optional parts, relay circuits, control panels, etc. System Examples
Indoor Unit Outdoor Unit
M Series Indoor Unit
SEZ, SLZ, SVZ
P Series Indoor Unit
M Series and MXZ Series Outdoor
SUZ and MXZ Series Outdoor
P Series Outdoor
Indoor unit MAC-334IF-E Indoor unit
PAR-40MAAU Control
Outdoor unit
PAR-40MAAU
PAR-40MAAU Outdoor unit
Details
• Wired remote controller can be connected to indoor unit
Standard equipment (for indoor units compatible with wired remote controllers)
Major Optional Parts Required
• MAC-334IF-E (Interface) • PAR-40MAAU (Wired remote controller)
• PAR-40MAAU (Wired remote controller)
Indoor unit
Indoor unit
Indoor unit
Indoor unit
MAC-334IF-E
System Group Control
Outdoor unit
PAR-40MAAU
Outdoor unit
Outdoor unit
Outdoor unit
Outdoor unit
Details
• One remote controller can control plural air conditioners with the same settings simultaneously. • One remote controller can control up to 16 refrigerant systems. (When connected to a MXZ unit, MAC-334IF-E is counted as one system.) • Up to two remote controller can be connected.
Major Optional Parts Required
• MAC-334IF-E (Interface) • PAR-40MAAU (Wired remote controller)
Outdoor unit
Outdoor unit
Indoor unit City Multi indoor unit
M-NET Connections
MAC-334IF-E
ME remote controller (PAR-F27MEA)
MELANS system controller (AE-200A etc) PAC-SC51KUA Power supply unit
Indoor unit
PAR-40MAAU
PAR-40MAAU Outdoor unit
124
Indoor unit
MAC-334IF-E
• PAR-40MAAU (Wired remote controller)
Outdoor unit
Outdoor unit
Indoor unit
Indoor unit
PAR-40MAAU MAC-334IF-E
Outdoor unit
PAR-40MAAU
PAC-SC51KUA Power supply kit City Multi indoor unit
MELANS system controller (AE-200A etc) PAC-SC51KUA Power supply unit
Indoor unit PAR-40MAAU PAC-YT53CRAU
Outdoor unit MELANS system controller (AE-200A etc)
Indoor unit
PAR-40MAAU
Outdoor unit M-NET adapter PAC-SF83MA-E
Details
• Group of air conditioners can be controlled by MELANS system controller (M-NET). Note: When connecting to M-NET, the reduction control for the power failure automatic recovery does not operate and it will take 3 minutes to restart.
Major Optional Parts Required
• MAC-334IF-E (M-NET Interface) • MELANS System controller • PAC-SC51KUA (power supply unit)
• PAC-SJ95MA-E/PAC-SJ96MA-E (M-NET converter) • MELANS System controller • PAC-SC51KUA (power supply unit)
For M-Series Indoor Units System Examples
1
Remote On/Off Operation
• Air conditioner can be started/ stopped remotely. ( 1 and 2 can be used in combination)
2
MAC-334IF-E Switch
Indoor unit
Remote control section (to be purchased locally)
Outdoor unit
Remote Display of Operation Status
• The On/Off status of air conditioners can be confirmed remotely. ( 1 and 2 can be used in combination)
Connection Details
Power supply
MAC-334IF-E
Resistance LED
Indoor unit Outdoor unit
Remote monitor section (to be purchased locally)
Control Details
Major Optional Parts Required
Connect the interface to the air conditioner. Then connect the locally purchased remote controller to the terminal in the interface.
On/Off operation is possible from a remote location.
• MAC-334IF-E (Interface) • Parts for circuit such as relay box, lead wire, etc. (to be purchased locally)
Connect the interface to the air conditioner. Then connect the locally purchased remote controller to the terminal in the interface.
The operation status (On/Off) or error signals can be monitored from a remote location.
• MAC-334IF-E (Interface) • Parts for circuit to be purchased locally (DC power source needed) • External power source (12V DC) is required when using MAC-334IF-E.
For P-Series and SLZ, SEZ and SVZ Indoor Units System Examples Wired remote controller
A
Wireless remote controller
2-remote Controller Control
• Up to two remote controllers can be connected to one group.
With two remote controllers, control can be performed locally and remotely from two locations.
PAR-FL32MA PAR-40MAAU
PAR-40MAAU
* Set "Main" and "Sub" remote controllers.
(Example of 1 : 1 system)
B
Operation Control by Level Signal
Air conditioner can be started/ stopped remotely. In addition, On/Off operation by local remote controller can be prohibited/permitted.
Remote control panel
Wired remote controller
Operation Control by Pulse Signal
Adapter for remote On/Off
Remote control panel
Remote operation adapter/ Connector cable for remote display + Relay box
PAR-FL32MA
Relay box (to be purchased locally) Connector cable for remote display Remote control panel
(Example of 1 : 1 system)
E
Timer Operation
Allows On/Off operation with timer *For control by an external timer, refer to B Operation Control by Level Signal.
PAR-40MAAU
(Example of 1 : 1 system)
• Adapter for remote On/Off PAC-SE55RA-E • Relay box (to be purchased locally) • Remote control panel (to be purchased locally)
• The pulse signal can be turned On/Off. • Operation/emergency signal can be received at a remote location.
• Connector cable for remote display PAC-SA88HA-E / PAC-725AD (10 pcs. x PAC-SA88HA-E) • Relay box (to be purchased locally) • Remote control panel (to be purchased locally)
• Operation/emergency signal can be received at a remote location (when channeled through the PAC-SF40RM-E no-voltage signal, when channeled through the PAC-SA88HA-E DC 12V signal).
• Remote display panel (to be purchased locally) • Connector cable for remote display PAC-SA88HA-E / PAC-725AD (10 pcs. x PAC-SA88HA-E) • Relay box (to be purchased locally) • Remote operation adapter PAC-SF40RM-E
PAR-FL32MA
Remote operation adapter/ Connector cable for remote display + Relay box
Remote display panel PAR-40MAAU
• Operation other than On/Off (e.g., adjustment of temperature, fan speed, and airflow) can be performed even when remote controller operation is prohibited. • Timer control is possible with an external timer.
(Example of 1 : 1 system x 2)
Operating status can be displayed at a remote location. Remote display panel
• Wired Remote Controller PAR-40MAAU • Wireless Remote Controller PAR-FL32MA • Wireless Remote Controller Kit for PCA PAR-SL93B-E
(Example of 1 : 1 system x 2)
Connector cable for remote display
(Example of 1 : 1 system x 2)
Remote Display of Operating Status
Relay box (to be purchased locally)
Relay box (to be purchased) locally)
Wired remote controller
• Both wired and wireless remote controllers can be used in combination.
Major Optional Parts Required
(Example of Simultaneous Twin)
Adapter for remote On/Off
Remote control panel
D
* When using wired and wireless remote controllers
Relay box (to be purchased) locally)
(Example of 1 : 1 system x 2)
C
Details
*Unable to use with wireless remote controller
PAR-FL32MA
(Example of Simultaneous Twin)
• Weekly Timer: On/Off and up to 8 pattern temperatures can be set for each calendar day. (Initial setting) • On/Off Timer: On/Off can be set once each within 72 hr in intervals of 5-minute units. • Auto-off Timer: Operation will be switched off after a certain time elapse. Set time can be changed from 30 min. to 4 hr. at 10 min. intervals.
Standard functions of PAR-40MAAU
*Simple Timer and Auto-off Timer cannot be used at the same time.
125
Other Optional Parts Part Name
Description
Part Name
Deodorizing Filter
Description
MAC-334IF-E System Control Interface
Captures small foul-smelling substances in the air.
Interface for connecting with the PAR-40MAAU remote controller and PACYT53CRAU, and to relay operation signals.
MAC-334 System Control Interface Indoor unit
Deodorising filter
Air cleaning Filter
Interface to connect with M-NET controllers.
Removes fine dust particles from the air by means of static electricity.
MAC-334IF-E Indoor unit
Air cleaning filter
Silver-ionized Air Purifier Filter
kumo cloudÂŽ Wireless Interface 2
Captures the bacteria, pollen and other allergens in the air and neutralizes them.
Silver-ionized Air Purifier Filter
Oil Mist Filter Element
Filter frame
Filter element (12 pieces) that blocks the oil mist for ceiling-suspended models used in professional kitchens.
Filter element
Interface enabling users to control air conditioners and check operating status via devices such as personal computers, tablets and smart phones.
Wireless Interface 2 Indoor unit
Smartphone
CN24 Relay Kit
This product is an adaptor which inputs the incoming signals from an open/close switch to the air conditioner and outputs the on/off signals from the air conditioner to the back-up heater.
Switch Indoor unit
Relay
Oil mist filter
High-efficiency Filter Element
Plug (for directing airflow)
Element for high-efficiency filter. Removes fine dust particles from the air.
High-efficiency filter element
Deluxe MA Wired Controller
Advanced deluxe remote controller with full dot liquid-crystal display and backlight. Equipped with convenient functions like night setback.
*For 4-way cassette units (PLA)
Shutter Plate
Simple MA Wired Controller
Plate for blocking an air outlet of the 4-way cassette (PLA) indoor unit.
Remote controller with liquid-crystal display, and backlight function for operation in dark location. Shutter Plate
Multi-functional Casement
Casement for fresh-air intake and attaching the high-efficiency filter element (optional).
Indoor unit body Multi-functional casement
Space Panel
Space Panel
Decorative cover for the installation when the ceiling height is low.
Remote Controller Terminal Block Kit for PKA
The terminal block is used as a relay to wire an indoor unit and to two remote controllers or to wire a remote controller and multiple indoor units in order to perform group control.
Wireless Remote Controller Signal Sender
Handheld unit for sending operation signals to the indoor unit. Panel
Drain Pump
Wireless Remote Controller Signal Receiver
Pumps drain water to a point higher than that where the unit is installed. Drain pump *for ceiling-suspended units
126
Handheld unit
Receives operation signals from the wireless remote controller handheld unit. Signal receiver
Part Name
Description
Wireless Remote Controller Kit (Sender & Receiver)
Part Name
Signal receiver
Description
Air Protection Guide/ Wind Baffle Protects the outdoor unit from the wind.
Remote controller handheld unit (signal sender) and receiver (signal receiver) for ceilingsuspended units.
Signal sender
Drain Socket
Control Holder
Holder for storing the remote controller. Control holder
A set of caps to cover unnecessary holes at the bottom of the outdoor unit, and a socket to guide drain water to the local drain pipe.
Cap Socket
Centralized Drain Pan
Remote Sensor
Catches drain water generated by the outdoor unit.
Sensor to detect the room temperature at remote positions.
Outdoor unit Centralized drain pan Base (local construction)
PAC-USSEN001-FM-1
PAC-715AD Remote On/Off Adapter
M-NET Converter
Remote on/off adapter
Used to connect P Series A-control models to M-NET controllers.
Connector for receiving signals from the local system to control the on/off function.
Remote Operation Adapter
Remote operation adapter
Adapter to display the operation status and control on/off function from a distance.
Group remote controller
M-NET Converter
Power supply unit for transmit cable
Control/Service Tool
Monitoring tool to display operation and selfdiagnosis data.
Control/service tool
PAC-725AD Connector Plug for Remote Display
Connector cable for remote display
Connector used to display the operation status and control on/off function from a distance.
Distribution Pipe
Indoor unit
Air Discharge Guide
Changes the direction of air being exhausted from the outdoor unit.
Indoor unit
Branch pipe for P Series simultaneous multisystem use, or to connect two branch boxes for MXZ.
Outdoor unit
Distribution pipe *P Series with 2 indoor units
Joint Pipe
Part for connecting refrigerant pipes of different diameters.
Joint pipe
Insulator
Branch Box Outer Cover Casement for branch boxes.
Onsite pipe
Indoor unit Outdoor unit
Complete view
Branch box outer cover
127
Optional Parts List for Indoor [M-Series] Wall Mount MSZ-FH
Filter
Filter Box
Grille
i-see Sensor Panel Casement Space Panel Shutter Plate Bottom Return Plate
Drain Pump
Condensate
Disconnect Switch Terminal Block Electric Heat Lockout Downflow Kit
Electric Kit Heats
Floor Mount Air Guide
128
Deodorizing Filter
MAC-3000FT-E
Anti-allergy Enzyme Filter
MAC-408FT-E
Anti-allergy Enzyme Filter
MAC-1415FT-E
Electrostatic Anti-allergy Enzyme Filter
MAC-2330FT-E
Electrostatic Anti-allergy Enzyme Filter
MAC-2320FT-E
Electrostatic Anti-allergy Enzyme Filter
MAC-2310FT-E
High Efficiency (MERV 8) Filter Element
PAC-SE81KF-E
High-efficiency Filter Element
PAC-SH59KF-E
High-efficiency Filter Element
PAC-SH89KF-E
High-efficiency Filter Element
PAC-SH90KF-E
Filter Box with MERV 8 Filters
FBL 1-1
Filter Box with MERV 8 Filters
FBL 1-2
Filter Box with MERV 8 Filters
FBL 1-3
Filter Box with MERV 13 Filters
FBM2-2-A
Filter Box with MERV 13 Filters
FBM2-3-A
Filter Box with MERV 13 Filters
FBM2-4-A
Grille (required)
MLP-444W
Grille (required)
SLP-15AAUW
Grille (required)
SLP-18FAU
i-see Sensor™
PAC-SH91MK-E
3D i-see Sensor® Corner Panel
PAC-SF1ME-E
Grille with 3D i-see Sensor®
SLP-18FAEU
Grille with 3D i-see Sensor®
PLP-40EAEU / PLP-41EAEU
Multi-function Casement
PAC-SJ41TM-E
Installation/Trim Panels
PLFY-ITP1
Installation/Trim Panels
PLFY-ITP2
Space Panel
PAC-SJ38AS-E
Shutter Plate
PAC-SJ37SP-E
Converts low-profile ducted unit from rear to bottom
BRP-1
Converts low-profile ducted unit from rear to bottom
BRP-2
Converts low-profile ducted unit from rear to bottom
BRP-3
External Drain Pump
PAC-KE07DM-E
External Drain Pump
PAC-SH94DM-E
External Drain Pump
PAC-SH75DM-E
MSZ-EF
06NA
09NA
12NA
15NA
18NA2
●
●
●
●
●
●
●
●
●
●
09NAW (B)(S)
12NAW (B)(S)
15NAW (B)(S)
18NAW (B)(S)
●
●
●
●
●
External Drain Pump
PAC-SH84DM-E
Blue Diamond Sensor Extension Cable — 15 Ft.
C13-103
●
●
●
●
●
●
●
●
Blue Diamond Alarm Extension Cable — 6.5 Ft.
C13-192
●
●
●
●
●
●
●
●
●
Blue Diamond MultiTank — collection tank for use with C21-014 multiple pumps
●
●
●
●
●
●
●
●
●
Blue Diamond Rubber Foot Pads
F10-010
●
●
●
●
●
●
●
●
●
Mini Condensate Pump — 230 volt application
SI30-230
●
●
●
●
●
●
●
●
●
MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor
X87-835 - 110 to 250V
●
●
●
●
●
●
●
●
●
MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 BTU/H [recommended]
X87-711 - 110V
●
●
●
●
●
●
●
●
●
Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended]
X87-721 - 208/230V
●
●
●
●
●
●
●
●
●
MicroBlue Blue Diamond Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H
X85-003
●
●
●
●
●
●
●
●
●
Fascia Kit for MicroBlue Pump, mounts the MicroBlue T18-016 and sensor directly beneath indoor unit
●
●
●
●
●
●
●
●
●
Drain Pan Level Sensor
SS610E
●
●
●
●
●
●
●
●
●
(30A/600V/UL) [fits 2" X 4" utility box] - Black
TAZ-MS303
●
●
●
●
●
●
●
●
●
(30A/600V/UL) [fits 2" X 4" utility box] - White
TAZ-MS303W
●
●
●
●
●
●
●
●
●
Separate Power Terminal Block Kit
SPTB1
Electric Heat Lockout Control
ETC-211000-MIT
Downflow Kit
DFK-S
Downflow Kit
DFK-M
Condensate Mgmt. Kit for downflow installation
CMA-1
3kW Electric Heater
EH03-MPA-S(B)
5kW Electric Heater
EH05-MPA-S(B)
8kW Electric Heater
EH08-MPA-S(B)
3kW Electric Heater
EH03-MPA-M(B)
5kW Electric Heater
EH05-MPA-M(B)
8kW Electric Heater
EH08-MPA-M(B)
3kW Electric Heater
EH03-SVZ-S
5kW Electric Heater
EH05-SVZ-S
8kW Electric Heater
EH08-SVZ-S
5kW Electric Heater
EH05-SVZ-M
8kW Electric Heater
EH08-SVZ-M
10kW Electric Heater
EH10-SVZ-M
10kW Electric Heater
EH10-MPA-M(B)
10kW Electric Heater
EH10-MPA-L(B)
15kW Electric Heater
EH15-MPAS- L(B)
17kW Electric Heater
EH17- MPAS-L(B)
Guides air flow for floor mount model when a concealer is used to hide the floor mount.
MAC-760FD-E
Wall Mount MSZ-GL
MSZ-D
06NA
09NA
12NA
15NA
18NA
●
●
●
●
●
24NA
30NA
36NA
●
●
MSZ-HM
MSZ-JP
09NA
12NA
15NA
18NA
●
●
●
●
MSZ-WR
24NA 09WA 12WA 09NA
●
●
●
●
MSY-GL
MSY-D
12NA
18NA
24NA
09NA
12NA
15NA
18NA
●
●
●
●
●
●
●
●
24NA
30NA
36NA
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
129
Optional Parts List for Indoor [M-Series]
Filter
Filter Box
Grille
i-see Sensor Panel Casement Space Panel Shutter Plate Bottom Return Plate
Drain Pump
Condensate
Deodorizing Filter
MAC-3000FT-E
Anti-allergy Enzyme Filter
MAC-408FT-E
Anti-allergy Enzyme Filter
MAC-1415FT-E
Electrostatic Anti-allergy Enzyme Filter
MAC-2330FT-E
Electrostatic Anti-allergy Enzyme Filter
MAC-2320FT-E
Electrostatic Anti-allergy Enzyme Filter
MAC-2310FT-E
High Efficiency (MERV 8) Filter Element
PAC-SE81KF-E
High-efficiency Filter Element
PAC-SH59KF-E
High-efficiency Filter Element
PAC-SH89KF-E
High-efficiency Filter Element
PAC-SH90KF-E
Filter Box with MERV 8 Filters
FBL 1-1
Filter Box with MERV 8 Filters
FBL 1-2
Filter Box with MERV 8 Filters
FBL 1-3
Filter Box with MERV 13 Filters
FBM2-2-A
Filter Box with MERV 13 Filters
FBM2-3-A
Filter Box with MERV 13 Filters
FBM2-4-A
Grille (required)
MLP-444W
Grille (required)
SLP-15AAUW
Grille (required)
SLP-18FAU
i-see Sensor™
PAC-SH91MK-E
3D i-see Sensor® Corner Panel
PAC-SF1ME-E
Grille with 3D i-see Sensor®
SLP-18FAEU
Grille with 3D i-see Sensor®
PLP-40EAEU / PLP-41EAEU
Multi-function Casement
PAC-SJ41TM-E
Installation/Trim Panels
PLFY-ITP1
Installation/Trim Panels
PLFY-ITP2
Space Panel
PAC-SJ38AS-E
Shutter Plate
PAC-SJ37SP-E
Converts low-profile ducted unit from rear to bottom
BRP-1
Converts low-profile ducted unit from rear to bottom
BRP-2
Floor Mount
EZ FIT™
MFZ-KJ
MLZ-KP
09NA
12NA
15NA
18NA
09NA
12NA
18NA
●
●
●
●
●
●
●
●
●
●
Converts low-profile ducted unit from rear to bottom
BRP-3
External Drain Pump
PAC-KE07DM-E
External Drain Pump
PAC-SH94DM-E
External Drain Pump
PAC-SH75DM-E
External Drain Pump
PAC-SH84DM-E
Blue Diamond Sensor Extension Cable — 15 Ft.
C13-103
●
●
●
Blue Diamond Alarm Extension Cable — 6.5 Ft.
C13-192
●
●
●
●
Blue Diamond MultiTank — collection tank for use with C21-014 multiple pumps
●
●
●
●
Blue Diamond Rubber Foot Pads
F10-010
●
●
●
●
Mini Condensate Pump — 230 volt application
SI30-230
●
●
●
●
MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor
X87-835 - 110 to 250V
●
●
●
●
●
●
●
MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 BTU/H [recommended]
X87-711 - 110V
●
●
●
●
●
●
●
Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended]
X87-721 - 208/230V
●
●
●
●
●
●
●
MicroBlue Blue Diamond Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H
X85-003
●
Fascia Kit for MicroBlue Pump, mounts the MicroBlue T18-016 and sensor directly beneath indoor unit
Disconnect Switch Terminal Block Electric Heat Lockout Downflow Kit
Electric Kit Heats
Floor Mount Air Guide
130
Drain Pan Level Sensor
SS610E
●
●
●
●
(30A/600V/UL) [fits 2" X 4" utility box] - Black
TAZ-MS303
●
●
●
●
●
●
●
(30A/600V/UL) [fits 2" X 4" utility box] - White
TAZ-MS303W
●
●
●
●
●
●
●
Separate Power Terminal Block Kit
SPTB1
●
●
●
●
Electric Heat Lockout Control
ETC-211000-MIT
Downflow Kit
DFK-S
Downflow Kit
DFK-M
Condensate Mgmt. Kit for downflow installation
CMA-1
3kW Electric Heater
EH03-MPA-S(B)
5kW Electric Heater
EH05-MPA-S(B)
8kW Electric Heater
EH08-MPA-S(B)
3kW Electric Heater
EH03-MPA-M(B)
5kW Electric Heater
EH05-MPA-M(B)
8kW Electric Heater
EH08-MPA-M(B)
3kW Electric Heater
EH03-SVZ-S
5kW Electric Heater
EH05-SVZ-S
8kW Electric Heater
EH08-SVZ-S
5kW Electric Heater
EH05-SVZ-M
8kW Electric Heater
EH08-SVZ-M
10kW Electric Heater
EH10-SVZ-M
10kW Electric Heater
EH10-MPA-M(B)
10kW Electric Heater
EH10-MPA-L(B)
15kW Electric Heater
EH15-MPAS- L(B)
17kW Electric Heater
EH17- MPAS-L(B)
Guides air flow for floor mount model when a concealer is used to hide the floor mount.
MAC-760FD-E
09NA
4-way Ceiling Cassette
Horizontal-ducted
Multi-position Air Handler
SLZ-KF
SEZ-KD
SVZ-KP
12NA
15NA
18NA
09NA4
12NA4
15NA4
●
●
18NA4
12NA
18NA
24NA
30NA
36NA
●
●
●
●
●
●
●
●
●
●
● ●
●
●
●
●
●
●
●
●
●
●
●
●
● ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
● ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
131
Optional Parts List for Indoor [P-Series] A12HA7 A18HA7
Filter
Filter Box
Grille
i-see Sensor Panel
Deodorizing Filter
MAC-3000FT-E
Anti-allergy Enzyme Filter
MAC-408FT-E
Anti-allergy Enzyme Filter
MAC-1415FT-E
Electrostatic Anti-allergy Enzyme Filter
MAC-2330FT-E
Electrostatic Anti-allergy Enzyme Filter
MAC-2320FT-E
Electrostatic Anti-allergy Enzyme Filter
MAC-2310FT-E
High Efficiency (MERV 8) Filter Element
PAC-SE81KF-E
High-efficiency Filter Element
PAC-SH59KF-E
High-efficiency Filter Element
PAC-SH89KF-E
High-efficiency Filter Element
PAC-SH90KF-E
Filter Box with MERV 8 Filters
FBL 1-1
Filter Box with MERV 8 Filters
FBL 1-2
Filter Box with MERV 8 Filters
FBL 1-3
Filter Box with MERV 13 Filters
FBM2-2-A
Filter Box with MERV 13 Filters
FBM2-3-A
Filter Box with MERV 13 Filters
FBM2-4-A
Grille (required)
MLP-444W
Grille (required)
SLP-15AAUW
Grille (required)
SLP-18FAU
i-see Sensor™
PAC-SH91MK-E
3D i-see Sensor® Corner Panel
PAC-SF1ME-E
Grille with 3D i-see Sensor®
SLP-18FAEU
Grille with 3D i-see Sensor®
PLP-40EAEU / PLP-41EAEU
Casement
Multi-function Casement
PAC-SJ41TM-E
Installation/Trim Panels
PLFY-ITP1
Space Panel
Installation/Trim Panels
PLFY-ITP2
Space Panel
PAC-SJ38AS-E
Shutter Plate
PAC-SJ37SP-E
Converts low-profile ducted unit from rear to bottom
BRP-1
Converts low-profile ducted unit from rear to bottom
BRP-2
Shutter Plate Bottom Return Plate
Drain Pump
Converts low-profile ducted unit from rear to bottom
BRP-3
External Drain Pump
PAC-KE07DM-E
External Drain Pump
PAC-SH94DM-E
External Drain Pump
PAC-SH75DM-E
External Drain Pump
PAC-SH84DM-E
Blue Diamond Sensor Extension Cable — 15 Ft.
C13-103
Blue Diamond Alarm Extension Cable — 6.5 Ft.
C13-192
Wall Mount
Ceiling-suspended
PKA
PCA-
A24KA7
A30KA7
A36KA7
A24KA7
A30KA7
A36KA7
A42KA7
●
●
●
●
●
● ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Blue Diamond MultiTank — collection tank for use with C21-014 multiple pumps Blue Diamond Rubber Foot Pads
Condensate
SI30-230
●
●
●
●
●
MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor
X87-835 - 110 to 250V
●
●
●
●
●
●
●
●
●
X87-721 - 208/230V
●
●
●
●
●
●
●
●
●
X85-003
●
●
MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 BTU/H [recommended] Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] MicroBlue Blue Diamond Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H
Disconnect Switch Terminal Block Electric Heat Lockout Downflow Kit
Electric Kit Heats
Floor Mount Air Guide
132
F10-010
Mini Condensate Pump — 230 volt application
X87-711 - 110V
Fascia Kit for MicroBlue Pump, mounts the MicroBlue T18-016 and sensor directly beneath indoor unit
●
●
Drain Pan Level Sensor
SS610E
●
●
●
●
●
(30A/600V/UL) [fits 2" X 4" utility box] - Black
TAZ-MS303
●
●
●
●
●
●
●
●
●
(30A/600V/UL) [fits 2" X 4" utility box] - White
TAZ-MS303W
●
●
●
●
●
●
●
●
●
Separate Power Terminal Block Kit
SPTB1
Electric Heat Lockout Control
ETC-211000-MIT
Downflow Kit
DFK-S
Downflow Kit
DFK-M
Condensate Mgmt. Kit for downflow installation
CMA-1
3kW Electric Heater
EH03-MPA-S(B)
5kW Electric Heater
EH05-MPA-S(B)
8kW Electric Heater
EH08-MPA-S(B)
3kW Electric Heater
EH03-MPA-M(B)
5kW Electric Heater
EH05-MPA-M(B)
8kW Electric Heater
EH08-MPA-M(B)
3kW Electric Heater
EH03-SVZ-S
5kW Electric Heater
EH05-SVZ-S
8kW Electric Heater
EH08-SVZ-S
5kW Electric Heater
EH05-SVZ-M
8kW Electric Heater
EH08-SVZ-M
10kW Electric Heater
EH10-SVZ-M
10kW Electric Heater
EH10-MPA-M(B)
10kW Electric Heater
EH10-MPA-L(B)
15kW Electric Heater
EH15-MPAS- L(B)
17kW Electric Heater
EH17- MPAS-L(B)
Guides air flow for floor mount model when a concealer is used to hide the floor mount.
MAC-760FD-E
*1 2 pieces required, *2 PEAD12/SUZ-KA12NAR1
4-way Ceiling Cassette
Ceiling-conceald
Multi-position Air Handler
PLA-
PEAD-
PVA-
A12EA7 A18EA7 A24EA7 A30EA7 A36EA7 A42EA7 A09AA7 A12AA7 A15AA7 A18AA7 A24AA7 A30AA7 A36AA7 A42AA7 A12AA7 A18AA7 A24AA7 A30AA7 A36AA7 A42AA7
●
●
●
●
●
●
●
●
●
● ●
● ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
● ●
● ● ●
●
●
●
●
●
●
● ● ●
● ● ●
133
Optional Parts List for Outdoor [M-Series] Distribution pipe Distribution pipe for Branch box
Port Adapter
Branch Box
Air Outlet Guide
Front Wind Baffle Rear Advanced Wind Baffle Side Advanced Wind Baffle
Drain Socket
Optional Defrost Heater
Centralized Drain Pan
M-NET Converter Control/Service Tool Ball Valve
Hail Guards
Outdoor Unit Mounting Pad
Outdoor Unit Stand
Wall Blacket
Lineset
Twinning Distribution Pipe (50:50) Flare Connection Brazed Port Adapter size: 3/8" x 5/8" Port Adapter size: 1/4" x 3/8" Port Adapter size: 3/8" X 1/2" Port Adapter size: 1/2" X 3/8" Port Adapter size: 1/2" X 5/8" Port Adapter size: 5/8" x 3/4" Branch Box Branch Box Branch Box Outer Cover Air Outlet Guide Air Outlet Guide Air Outlet Guide Air Outlet Guide Air Outlet Guide Air Outlet Guide Front Wind Baffle Front Wind Baffle Front Wind Baffle Rear Advanced Wind Baffle Rear Advanced Wind Baffle Rear Advanced Wind Baffle Side Advanced Wind Baffle Side Advanced Wind Baffle Side Advanced Wind Baffle Drain Socket (1st-gen) Drain Socket Drain Socket Drain Socket Drain Socket Drain Socket Drain Socket (6-gen) Drain Socket Optional Defrost Heater Optional Defrost Heater Optional Defrost Heater Optional Defrost Heater Optional Defrost Heater Optional Defrost Heater Centralized Drain Pan Centralized Drain Pan Centralized Drain Pan M-NET Converter M-NET Converter M-NET Converter M-NET Converter M-NET Converter Control/Service Tool Refrigeration Ball Valve-Flare/Schrader/Insulated — 1/2" size Refrigeration Ball Valve-Flare/Schrader/Insulated — 1/4" size Refrigeration Ball Valve-Flare/Schrader/Insulated — 3/8" size Refrigeration Ball Valve-Flare/Schrader/Insulated — 5/8" size Hail Guard Hail Guard Hail Guard Hail Guard Hail Guard Hail Guard Hail Guard Hail Guard Hail Guard Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic Condensing Unit Mounting Pad 16" x 36" x 3" Condensing Unit Mounting Pad 24" x 42" x 3" Outdoor Unit Stand — 12" High Outdoor Unit Stand — 18" High Outdoor Unit Stand — 24" High Outdoor Unit Stand — 12" High Outdoor Unit Stand — 18" High Outdoor Unit Stand — 24"High Heavy Duty Wall Mounting Bracket— Coated Steel Heavy Duty Wall Mounting Bracket — 316 Series Stainless Steel 15' x 1/4" x 15' / 3/8" Lineset (Twin-Tube Insulation) 30' x 1/4" x 30' / 3/8" Lineset (Twin-Tube Insulation) 50' x 1/4" x 50' / 3/8" Lineset (Twin-Tube Insulation) 65' x 1/4" x 65' / 3/8" Lineset (Twin-Tube Insulation) 15' x 1/4" x 15' / 1/2" Lineset (Twin-Tube Insulation) 30' x 1/4" x 30' / 1/2" Lineset (Twin-Tube Insulation) 50' x 1/4" x 50' / 1/2" Lineset (Twin-Tube Insulation) 65' x 1/4" x 65' / 1/2" Lineset (Twin-Tube Insulation) 100' x 1/4" x 100' / 1/2" Lineset (Twin-Tube Insulation) 10' x 3/8" x 10' x 5/8" Lineset (Twin-Tube Insulation) 15' x 3/8" x 15' x 5/8" Lineset (Twin-Tube Insulation) 30' x 3/8" x 30' x 5/8" Lineset (Twin-Tube Insulation) 50' x 3/8" x 50' x 5/8" Lineset (Twin-Tube Insulation) 65' x 3/8" x 65' x 5/8" Lineset (Twin-Tube Insulation) 100' x 3/8" x 100' x 5/8" Lineset (Twin-Tube Insulation) 15' x 3/8" x 15' / 3/4" Lineset (Twin-Tube Insulation) 50' x 3/8" x 50' / 3/4" Lineset (Twin-Tube Insulation) *1 2 pieces required, *2 PEAD12/SUZ-KA12NAR1
134
MSDD-50TR-E MSDD-50AR-E MSDD-50BR-E PAC-SG76RJ-E PAC-493PI MAC-A454JP-E MAC-A455JP-E MAC-A456JP-E ADP5834 PAC-MKA52BC PAC-MKA32BC BBE-1 MAC-881SG MAC-886SG-E MAC-856SG PAC-SH96SG-E PAC-SJ07SG-E PAC-SG59SG-E WB-PA3 WB-PA4 WB-PA5 WB-RE4 WB-RE5 WB-RE6 WB-SD4 WB-SD5 WB-SD6 PAC-SF37DS-E PAC-SG60DS-E PAC-SG61DS-E MAC-860DS MAC-811DS MAC-851DS PAC-SH71DS-E PAC-SJ08DS-E MAC-640BH-U MAC-641BH-U MAC-642BH-U1 PAC-645BH-E PAC-646BH-E PAC-SJ20BH-E PAC-SH97DP-E PAC-SG63DP-E PAC-SG64DP-E PAC-IF01MNT-E PAC-SJ19MA-E PAC-SJ85MA-E PAC-SJ96MA-E PAC-SJ95MA-E PAC-SK52ST BV12FFSI2 BV14FFSI2 BV38FFSI2 BV58FFSI2 HG-A1 HG-A2 HG-A3 HG-B4 HG-A5 HG-A6 HG-A7 HG-A8 HG-A9 DSD-400P ULTRILITE1 ULTRILITE2 QSMS1201M QSMS1801M QSMS2401M QSMS1202M QSMS1802M QSMS2402M QSWB2000M-1 QSWBSS MLS143812T-15 MLS143812T-30 MLS143812T-50 MLS143812T-65 MLS141212T-15 MLS141212T-30 MLS141212T-50 MLS141212T-65 MLS141212T-100 MPLS385812T-10 MPLS385812T-15 MPLS385812T-30 MPLS385812T-50 MPLS385812T-65 MPLS385812T-100 MPLS383412T-15 MPLS383412T-50
06NA
09NA
12NA
●
●
●
●
●
●
●
●
●
●
●
MUZ-FH 15NA 18NA2
●
●
●
●
●
●
●
●
●
06NAH
09NAH
12NAH
●
●
●
●
●
●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ●
● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
MUZ-FH MUZ-GL 15NAH 18NAH2 09NA-U2 12NA-U2 15NA-U2 18NA-U2 24NA-U2
● ●
●
●
●
●
●
MUZ-D 30NA 36NA
●
●
●
●
●
●
●
●
●
●
● ●
● ●
● ●
● ●
● ● ●
● ● ●
● ● ●
● ●
● ●
● ●
● ● ● ● ●
● ● ● ● ●
MUZ-HM 15NA
18NA
●
●
●
●
24NA
MUY-GL 09NA-U2 12NA-U2 15NA-U2 18NA-U2 24NA-U2
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
● ●
12NA
●
●
●
09NA
●
●
●
●
●
●
●
●
●
●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
135
Optional Parts List for Outdoor [M-Series] MUY-D 30NA 36NA Distribution pipe Distribution pipe for Branch box
Port Adapter
Branch Box
Air Outlet Guide
Front Wind Baffle Rear Advanced Wind Baffle Side Advanced Wind Baffle
Drain Socket
Optional Defrost Heater
Centralized Drain Pan
M-NET Converter Control/Service Tool Ball Valve
Hail Guards
Outdoor Unit Mounting Pad
Outdoor Unit Stand
Wall Blacket
Lineset
Twinning Distribution Pipe (50:50) Flare Connection Brazed Port Adapter size: 3/8" x 5/8" Port Adapter size: 1/4" x 3/8" Port Adapter size: 3/8" X 1/2" Port Adapter size: 1/2" X 3/8" Port Adapter size: 1/2" X 5/8" Port Adapter size: 5/8" x 3/4" Branch Box Branch Box Branch Box Outer Cover Air Outlet Guide Air Outlet Guide Air Outlet Guide Air Outlet Guide Air Outlet Guide Air Outlet Guide Front Wind Baffle Front Wind Baffle Front Wind Baffle Rear Advanced Wind Baffle Rear Advanced Wind Baffle Rear Advanced Wind Baffle Side Advanced Wind Baffle Side Advanced Wind Baffle Side Advanced Wind Baffle Drain Socket (1st-gen) Drain Socket Drain Socket Drain Socket Drain Socket Drain Socket Drain Socket (6-gen) Drain Socket Optional Defrost Heater Optional Defrost Heater Optional Defrost Heater Optional Defrost Heater Optional Defrost Heater Optional Defrost Heater Centralized Drain Pan Centralized Drain Pan Centralized Drain Pan M-NET Converter M-NET Converter M-NET Converter M-NET Converter M-NET Converter Control/Service Tool Refrigeration Ball Valve-Flare/Schrader/Insulated — 1/2" size Refrigeration Ball Valve-Flare/Schrader/Insulated — 1/4" size Refrigeration Ball Valve-Flare/Schrader/Insulated — 3/8" size Refrigeration Ball Valve-Flare/Schrader/Insulated — 5/8" size Hail Guard Hail Guard Hail Guard Hail Guard Hail Guard Hail Guard Hail Guard Hail Guard Hail Guard Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic Condensing Unit Mounting Pad 16" x 36" x 3" Condensing Unit Mounting Pad 24" x 42" x 3" Outdoor Unit Stand — 12" High Outdoor Unit Stand — 18" High Outdoor Unit Stand — 24" High Outdoor Unit Stand — 12" High Outdoor Unit Stand — 18" High Outdoor Unit Stand — 24"High Heavy Duty Wall Mounting Bracket— Coated Steel Heavy Duty Wall Mounting Bracket — 316 Series Stainless Steel 15' x 1/4" x 15' / 3/8" Lineset (Twin-Tube Insulation) 30' x 1/4" x 30' / 3/8" Lineset (Twin-Tube Insulation) 50' x 1/4" x 50' / 3/8" Lineset (Twin-Tube Insulation) 65' x 1/4" x 65' / 3/8" Lineset (Twin-Tube Insulation) 15' x 1/4" x 15' / 1/2" Lineset (Twin-Tube Insulation) 30' x 1/4" x 30' / 1/2" Lineset (Twin-Tube Insulation) 50' x 1/4" x 50' / 1/2" Lineset (Twin-Tube Insulation) 65' x 1/4" x 65' / 1/2" Lineset (Twin-Tube Insulation) 100' x 1/4" x 100' / 1/2" Lineset (Twin-Tube Insulation) 10' x 3/8" x 10' x 5/8" Lineset (Twin-Tube Insulation) 15' x 3/8" x 15' x 5/8" Lineset (Twin-Tube Insulation) 30' x 3/8" x 30' x 5/8" Lineset (Twin-Tube Insulation) 50' x 3/8" x 50' x 5/8" Lineset (Twin-Tube Insulation) 65' x 3/8" x 65' x 5/8" Lineset (Twin-Tube Insulation) 100' x 3/8" x 100' x 5/8" Lineset (Twin-Tube Insulation) 15' x 3/8" x 15' / 3/4" Lineset (Twin-Tube Insulation) 50' x 3/8" x 50' / 3/4" Lineset (Twin-Tube Insulation) *1 2 pieces required, *2 PEAD12/SUZ-KA12NAR1
136
MSDD-50TR-E MSDD-50AR-E MSDD-50BR-E PAC-SG76RJ-E PAC-493PI MAC-A454JP-E MAC-A455JP-E MAC-A456JP-E ADP5834 PAC-MKA52BC PAC-MKA32BC BBE-1 MAC-881SG MAC-886SG-E MAC-856SG PAC-SH96SG-E PAC-SJ07SG-E PAC-SG59SG-E WB-PA3 WB-PA4 WB-PA5 WB-RE4 WB-RE5 WB-RE6 WB-SD4 WB-SD5 WB-SD6 PAC-SF37DS-E PAC-SG60DS-E PAC-SG61DS-E MAC-860DS MAC-811DS MAC-851DS PAC-SH71DS-E PAC-SJ08DS-E MAC-640BH-U MAC-641BH-U MAC-642BH-U1 PAC-645BH-E PAC-646BH-E PAC-SJ20BH-E PAC-SH97DP-E PAC-SG63DP-E PAC-SG64DP-E PAC-IF01MNT-E PAC-SJ19MA-E PAC-SJ85MA-E PAC-SJ96MA-E PAC-SJ95MA-E PAC-SK52ST BV12FFSI2 BV14FFSI2 BV38FFSI2 BV58FFSI2 HG-A1 HG-A2 HG-A3 HG-B4 HG-A5 HG-A6 HG-A7 HG-A8 HG-A9 DSD-400P ULTRILITE1 ULTRILITE2 QSMS1201M QSMS1801M QSMS2401M QSMS1202M QSMS1802M QSMS2402M QSWB2000M-1 QSWBSS MLS143812T-15 MLS143812T-30 MLS143812T-50 MLS143812T-65 MLS141212T-15 MLS141212T-30 MLS141212T-50 MLS141212T-65 MLS141212T-100 MPLS385812T-10 MPLS385812T-15 MPLS385812T-30 MPLS385812T-50 MPLS385812T-65 MPLS385812T-100 MPLS383412T-15 MPLS383412T-50
MUFZ-KJ 09NAHZ 12NAHZ 15NAHZ 18NAHZ
●
● ●
●
MUZ-JP 09WA 12WA
●
●
●
●
●
●
●
●
●
●
●
●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ●
● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ●
● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
MUZ-WR 09NA 12NA 18NA 24NA
2C20NA2
● ● ● ● ●
●
●
3C24NA2
● ● ● ● ●
3C30NA2
● ● ● ● ●
MXZ4C36NA2
● ● ● ● ●
5C42NA2
8C48NA2
● ● ● ● ●
● ● ● ● ● ● ●
MXZ8C60NA2 2C20NAHZ2 3C24NAHZ2 3C30NAHZ2 4C36NAHZ2 5C42NAHZ2 8C48NAHZ2
● ● ●
● ● ● ● ● ● ● ● ● ● ●
●*1
●*1
●*1
●*1
●
●
● ●
● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ● ● ●
● ● ● ● ● ● ●
● ● ● ● ● ● ●
● ● ●
● ● ●
● ● ●
●*1
●*1
●*1
●*1
●*1
●*1
●
●
●
● ● ● ●
● ● ● ●
●
●
●
● ● ●
●
● ●
●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ●
● ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
● ●
●
●
●
●
●
●
●
●
●
●
●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ● ●
● ● ● ●
● ● ● ●
●
●
● ●
● ●
●
●
●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ●
● ●
● ●
● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ●
● ●
● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ● ●
● ●
● ●
● ● ●
● ● ●
● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ●
● ●
137
Optional Parts List for Outdoor [M-Series] 09NA2 Distribution pipe
Twinning Distribution Pipe (50:50)
MSDD-50TR-E
Distribution pipe for Branch box
Flare Connection
MSDD-50AR-E
Brazed Port Adapter size: 3/8" x 5/8" Port Adapter size: 1/4" x 3/8" Port Adapter size: 3/8" x 1/2" Port Adapter size: 1/2" x 3/8" Port Adapter size: 1/2" x 5/8" Port Adapter size: 5/8" x 3/4" Branch Box Branch Box Branch Box Outer Cover Air Outlet Guide Air Outlet Guide Air Outlet Guide Air Outlet Guide Air Outlet Guide Air Outlet Guide Front Wind Baffle Front Wind Baffle Front Wind Baffle Rear Advanced Wind Baffle Rear Advanced Wind Baffle Rear Advanced Wind Baffle Side Advanced Wind Baffle Side Advanced Wind Baffle Side Advanced Wind Baffle Drain Socket (1st-gen) Drain Socket Drain Socket Drain Socket Drain Socket Drain Socket Drain Socket (6-gen) Drain Socket Optional Defrost Heater Optional Defrost Heater Optional Defrost Heater Optional Defrost Heater Optional Defrost Heater Optional Defrost Heater Centralized Drain Pan Centralized Drain Pan Centralized Drain Pan M-NET Converter M-NET Converter M-NET Converter M-NET Converter M-NET Converter Control/Service Tool Refrigeration Ball Valve-Flare/Schrader/Insulated — 1/2" size Refrigeration Ball Valve-Flare/Schrader/Insulated — 1/4" size Refrigeration Ball Valve-Flare/Schrader/Insulated — 3/8" size Refrigeration Ball Valve-Flare/Schrader/Insulated — 5/8" size Hail Guard Hail Guard Hail Guard Hail Guard Hail Guard Hail Guard Hail Guard Hail Guard Hail Guard Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic Condensing Unit Mounting Pad 16" x 36" x 3" Condensing Unit Mounting Pad 24" x 42" x 3" Outdoor Unit Stand — 12" High Outdoor Unit Stand — 18" High Outdoor Unit Stand — 24" High Outdoor Unit Stand — 12" High Outdoor Unit Stand — 18" High Outdoor Unit Stand — 24"High Heavy Duty Wall Mounting Bracket— Coated Steel Heavy Duty Wall Mounting Bracket — 316 Series Stainless Steel 15' x 1/4" x 15' / 3/8" Lineset (Twin-Tube Insulation) 30' x 1/4" x 30' / 3/8" Lineset (Twin-Tube Insulation) 50' x 1/4" x 50' / 3/8" Lineset (Twin-Tube Insulation) 65' x 1/4" x 65' / 3/8" Lineset (Twin-Tube Insulation) 15' x 1/4" x 15' / 1/2" Lineset (Twin-Tube Insulation) 30' x 1/4" x 30' / 1/2" Lineset (Twin-Tube Insulation) 50' x 1/4" x 50' / 1/2" Lineset (Twin-Tube Insulation) 65' x 1/4" x 65' / 1/2" Lineset (Twin-Tube Insulation) 100' x 1/4" x 100' / 1/2" Lineset (Twin-Tube Insulation) 10' x 3/8" x 10' x 5/8" Lineset (Twin-Tube Insulation) 15' x 3/8" x 15' x 5/8" Lineset (Twin-Tube Insulation) 30' x 3/8" x 30' x 5/8" Lineset (Twin-Tube Insulation) 50' x 3/8" x 50' x 5/8" Lineset (Twin-Tube Insulation) 65' x 3/8" x 65' x 5/8" Lineset (Twin-Tube Insulation) 100' x 3/8" x 100' x 5/8" Lineset (Twin-Tube Insulation) 15' x 3/8" x 15' / 3/4" Lineset (Twin-Tube Insulation) 50' x 3/8" x 50' / 3/4" Lineset (Twin-Tube Insulation)
MSDD-50BR-E PAC-SG76RJ-E PAC-493PI MAC-A454JP-E MAC-A455JP-E MAC-A456JP-E ADP5834 PAC-MKA52BC PAC-MKA32BC BBE-1 MAC-881SG MAC-886SG-E MAC-856SG PAC-SH96SG-E PAC-SJ07SG-E PAC-SG59SG-E WB-PA3 WB-PA4 WB-PA5 WB-RE4 WB-RE5 WB-RE6 WB-SD4 WB-SD5 WB-SD6 PAC-SF37DS-E PAC-SG60DS-E PAC-SG61DS-E MAC-860DS MAC-811DS MAC-851DS PAC-SH71DS-E PAC-SJ08DS-E MAC-640BH-U MAC-641BH-U MAC-642BH-U1 PAC-645BH-E PAC-646BH-E PAC-SJ20BH-E PAC-SH97DP-E PAC-SG63DP-E PAC-SG64DP-E PAC-IF01MNT-E PAC-SJ19MA-E PAC-SJ85MA-E PAC-SJ96MA-E PAC-SJ95MA-E PAC-SK52ST BV12FFSI2 BV14FFSI2 BV38FFSI2 BV58FFSI2 HG-A1 HG-A2 HG-A3 HG-B4 HG-A5 HG-A6 HG-A7 HG-A8 HG-A9 DSD-400P ULTRILITE1 ULTRILITE2 QSMS1201M QSMS1801M QSMS2401M QSMS1202M QSMS1802M QSMS2402M QSWB2000M-1 QSWBSS MLS143812T-15 MLS143812T-30 MLS143812T-50 MLS143812T-65 MLS141212T-15 MLS141212T-30 MLS141212T-50 MLS141212T-65 MLS141212T-100 MPLS385812T-10 MPLS385812T-15 MPLS385812T-30 MPLS385812T-50 MPLS385812T-65 MPLS385812T-100 MPLS383412T-15 MPLS383412T-50
Port Adapter
Branch Box
Air Outlet Guide
Front Wind Baffle Rear Advanced Wind Baffle Side Advanced Wind Baffle
Drain Socket
Optional Defrost Heater
Centralized Drain Pan
M-NET Converter Control/Service Tool Ball Valve
Hail Guards
Outdoor Unit Mounting Pad
Outdoor Unit Stand
Wall Blacket
Lineset
*1 2 pieces required, *2 PEAD12/SUZ-KA12NAR1
138
SUZ-KA 12NA2
15NA2
●*2
●
●
●
●
●
●
●
●
●
● ●
● ●
● ●
● ● ●
● ● ●
● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
SUZ-KA 18NA2
24NA2
30NA2
36NA2
09NAHZ
SUZ-KANAHZ 12NAHZ 15NAHZ
18NAHZ
●*2
● ●
●
●
●
●
● ●
● ●
●
●
●
●
●
●
●
●
●
●
●
●
●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ●
● ●
● ●
● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ●
● ● ● ● ●
●
● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
139
Optional Parts List for Outdoor [P-Series] Distribution pipe Distribution pipe for Branch box
Port Adapter
Branch Box
Twinning Distribution Pipe (50:50) Flare Connection Brazed Port Adapter size: 3/8" x 5/8" Port Adapter size: 1/4" x 3/8" Port Adapter size: 3/8" X 1/2" Port Adapter size: 1/2" X 3/8" Port Adapter size: 1/2" X 5/8" Port Adapter size: 5/8" x 3/4" Branch Box Branch Box
Branch Box Outer Cover
Air Outlet Guide
Front Wind Baffle Rear Advanced Wind Baffle Side Advanced Wind Baffle
Drain Socket
Optional Defrost Heater
Centralized Drain Pan
M-NET Converter Control/Service Tool Ball Valve
Hail Guards
Outdoor Unit Mounting Pad
Outdoor Unit Stand
Wall Blacket
Lineset
Air Outlet Guide Air Outlet Guide Air Outlet Guide Air Outlet Guide Air Outlet Guide Air Outlet Guide Front Wind Baffle Front Wind Baffle Front Wind Baffle Rear Advanced Wind Baffle Rear Advanced Wind Baffle Rear Advanced Wind Baffle Side Advanced Wind Baffle Side Advanced Wind Baffle Side Advanced Wind Baffle Drain Socket (1st-gen) Drain Socket Drain Socket Drain Socket Drain Socket Drain Socket Drain Socket (6-gen) Drain Socket Optional Defrost Heater Optional Defrost Heater Optional Defrost Heater Optional Defrost Heater Optional Defrost Heater Optional Defrost Heater Centralized Drain Pan Centralized Drain Pan Centralized Drain Pan M-NET Converter M-NET Converter M-NET Converter M-NET Converter M-NET Converter Control/Service Tool Refrigeration Ball Valve-Flare/Schrader/Insulated — 1/2" size Refrigeration Ball Valve-Flare/Schrader/Insulated — 1/4" size Refrigeration Ball Valve-Flare/Schrader/Insulated — 3/8" size Refrigeration Ball Valve-Flare/Schrader/Insulated — 5/8" size Hail Guard Hail Guard Hail Guard Hail Guard Hail Guard Hail Guard Hail Guard Hail Guard Hail Guard Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic Condensing Unit Mounting Pad 16" x 36" x 3" Condensing Unit Mounting Pad 24" x 42" x 3" Outdoor Unit Stand — 12" High Outdoor Unit Stand — 18" High Outdoor Unit Stand — 24" High Outdoor Unit Stand — 12" High Outdoor Unit Stand — 18" High Outdoor Unit Stand — 24"High Heavy Duty Wall Mounting Bracket— Coated Steel Heavy Duty Wall Mounting Bracket — 316 Series Stainless Steel 15' x 1/4" x 15' / 3/8" Lineset (Twin-Tube Insulation) 30' x 1/4" x 30' / 3/8" Lineset (Twin-Tube Insulation) 50' x 1/4" x 50' / 3/8" Lineset (Twin-Tube Insulation) 65' x 1/4" x 65' / 3/8" Lineset (Twin-Tube Insulation) 15' x 1/4" x 15' / 1/2" Lineset (Twin-Tube Insulation) 30' x 1/4" x 30' / 1/2" Lineset (Twin-Tube Insulation) 50' x 1/4" x 50' / 1/2" Lineset (Twin-Tube Insulation) 65' x 1/4" x 65' / 1/2" Lineset (Twin-Tube Insulation) 100' x 1/4" x 100' / 1/2" Lineset (Twin-Tube Insulation) 10' x 3/8" x 10' x 5/8" Lineset (Twin-Tube Insulation) 15' x 3/8" x 15' x 5/8" Lineset (Twin-Tube Insulation) 30' x 3/8" x 30' x 5/8" Lineset (Twin-Tube Insulation) 50' x 3/8" x 50' x 5/8" Lineset (Twin-Tube Insulation) 65' x 3/8" x 65' x 5/8" Lineset (Twin-Tube Insulation) 100' x 3/8" x 100' x 5/8" Lineset (Twin-Tube Insulation) 15' x 3/8" x 15' / 3/4" Lineset (Twin-Tube Insulation) 50' x 3/8" x 50' / 3/4" Lineset (Twin-Tube Insulation) *1 2 pieces required, *2 PEAD12/SUZ-KA12NAR1
140
MSDD-50TR-E MSDD-50AR-E MSDD-50BR-E PAC-SG76RJ-E PAC-493PI MAC-A454JP-E MAC-A455JP-E MAC-A456JP-E ADP5834 PAC-MKA52BC PAC-MKA32BC BBE-1 MAC-881SG MAC-886SG-E MAC-856SG PAC-SH96SG-E PAC-SJ07SG-E PAC-SG59SG-E WB-PA3 WB-PA4 WB-PA5 WB-RE4 WB-RE5 WB-RE6 WB-SD4 WB-SD5 WB-SD6 PAC-SF37DS-E PAC-SG60DS-E PAC-SG61DS-E MAC-860DS MAC-811DS MAC-851DS PAC-SH71DS-E PAC-SJ08DS-E MAC-640BH-U MAC-641BH-U MAC-642BH-U1 PAC-645BH-E PAC-646BH-E PAC-SJ20BH-E PAC-SH97DP-E PAC-SG63DP-E PAC-SG64DP-E PAC-IF01MNT-E PAC-SJ19MA-E PAC-SJ85MA-E PAC-SJ96MA-E PAC-SJ95MA-E PAC-SK52ST BV12FFSI2 BV14FFSI2 BV38FFSI2 BV58FFSI2 HG-A1 HG-A2 HG-A3 HG-B4 HG-A5 HG-A6 HG-A7 HG-A8 HG-A9 DSD-400P ULTRILITE1 ULTRILITE2 QSMS1201M QSMS1801M QSMS2401M QSMS1202M QSMS1802M QSMS2402M QSWB2000M-1 QSWBSS MLS143812T-15 MLS143812T-30 MLS143812T-50 MLS143812T-65 MLS141212T-15 MLS141212T-30 MLS141212T-50 MLS141212T-65 MLS141212T-100 MPLS385812T-10 MPLS385812T-15 MPLS385812T-30 MPLS385812T-50 MPLS385812T-65 MPLS385812T-100 MPLS383412T-15 MPLS383412T-50
12NKA7 (-BS)
18NKA7 (-BS)
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
● ● ●
PUY-A 24NHA7 30NHA7 (-BS) (-BS) ●
●
●
●
●
●
●
●
●
●
●
36NKA7 (-BS) ●
42NKA7 (-BS)
●*1
●*1
●*1
●*1
●
●
●
●
●
●
●
●
●
●
●
●
●
●
● ●
● ●
● ●
● ●
●
●
●
●
● ● ● ● ●
● ● ● ● ● ●
●
●
● ● ●
● ● ● ●
● ● ● ●
● ●
● ●
● ●
● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
PUZ-A 12NKA7(-BS)
18NKA7(-BS)
24NHA7(-BS)
PUZ-HA
30NHA7(-BS)
●
● ●
●
● ●
36NKA7(-BS)
42NKA7(-BS)
24NHA
30NHA5
●
●
●
●
●
●
●
36NHA5
42NKA
●
●*1
●*1
●*1
●*1
●
●
●
●
●*1 ●
●
●
●
●
●
●
●
●
●*1
●
●
●
●
●
●
●
●
●
●
●
●
●
●
● ● ●
●
●
●
●
●
●
● ●
● ●
● ●
● ●
●
●
●
●
● ● ●
● ● ● ●
● ● ● ●
● ●
● ●
● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ● ●
● ●
●
●
●
●
●
●
● ●
● ●
● ●
● ●
●
●
●
●
●
● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
●
●
●
●
●
● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ●
141
Optional Parts List for Controllers Wall Mount MSZ-FH
Wireless Signal Receiver
Wireless Remote Controller
Wired Remote Controller
Remote Sensor
12NAW (B)(S)
06NA
09NA
12NA
15NA
18NA2
15NAW (B)(S)
18NAW (B)(S)
●
●
●
●
●
●
●
●
●
Wireless Signal Receiver
PAR-SA9CA-E
Wireless Signal Receiver
PAR-FA32MA-W
Wireless Signal Receiver
PAR-FA32MA-E
Wireless Remote Receiver Panel
PAR-SF9FA-E
Wireless Remote Receiver Panel
PAR-SR3LA-E
Remote Controller Holder
U01A01083
Wireless Remote Controller
PAR-SL100A-E
Wireless Remote Controller
PAR-FL32MA-E
Controller Kit (Sender & Receiver)
PAR-SL93B-E
Controller Kit with i-see Sensor™
PAR-SA92MW-E
kumo touch™ Backlit, Wall-mounted, Wireless Controller
MHK2
Deluxe MA Remote Controller
PAR-40MAAU
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
Simple MA Controller
PAC-YT53CRAU-J
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
Touch MA Controller
PAR-CT01MAU-SB
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
Airzone ZBS Wired Blueface Principal Controller White
AZZBSBLUEFACECB
Airzone ZBS Wired Think Controller White
AZZBSTHINKCB
Airzone ZBS Wireless Think Controller White
AZZBSTHINKRB
Airzone ZBS Wired Lite Controller White
AZZBSLITECB
Airzone ZBS Wireless Lite Controller White
AZZBSLITERB
Wired Remote Sensor
PAC-SE41TS-E
Wired Remote Sensor
M21EAA307
●
●
●
●
●
●
●
●
●
Wireless Temperature and Humidity Sensor
PAC-USWHS003-TH-1
●
●
●
●
●
●
●
●
●
Flush Mount Remote Temperature Sensor
PAC-USSEN001-FM-1
System Control Interface
MAC-3334F-E
●*3
●*3
●*3
●*3
●*3
●*3
●*3
●*3
●*3
Wireless Interface 2
PAC-USWHS002-WF-2
●
●
●
●
●
●
●
●
●
Thermostat Interface
PAC-US444CN-1
●
●
●
●
●
●
●
●
●
kumo station®
PAC-WHS01HC-E
●
●
●
●
●
●
●
●
●
USNAP Interface
PAC-WHS01UP-E
●
●
●
●
●
●
●
●
●
IT Extender
PAC-WHS01IE-E
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
BACnet and MODBUS Interface
PAC-UKPRC001-CN-1
●
●
●
●
●
External Fan / Heater Control Relay Adapter
CN24RELAY-KIT-CM3
●
●
●
●
●
Wire for Remote on/off with CN32 connector
PAC-715AD
●
●
●
●
●
®
Interface
MSZ-EF 09NAW (B)(S)
®
Connector and wire for Operation status/error using CN51 PAC-725AD Connector cable for remote display
PAC-SA88HA-EP
Connector for CN32 (remote on/off)
PAC-SE55RA-E
Lockdown Bracket for Hand-held Remote Controllers
RCMKP1CB
Remote Operation Adapter
PAC-SF40RM-E
●*1 (requires MAC-334IF-E), ●*2 Unable to use with wireless remote controller ●*3 Allows indoor units to connect to an MA controller
142
Wall Mount MSZ-GL 06NA
09NA
12NA
15NA
MSZ-D 18NA
24NA
30NA
36NA
MSZ-HM
MSZ-JP
09NA
12NA
15NA
18NA
●
●
●
●
●
MSZ-WR
24NA 09WA 12WA 09NA
MSY-GL
12NA
18NA
24NA
●
●
●
●
MSY-D
09NA
12NA
15NA
18NA
24NA
30NA
36NA
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●*3
●*3
●*3
●*3
●*3
●*3
●*3
●*3
●*3
●*3
●*3
●*3
●*3
●*3
●*3
●*3
●*3
●*3
●*3
●*3
●*3
●*3
●*3
●*3
●*3
●*3
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
143
Optional Parts List for Controllers Floor Mount
EZ FIT™
MFZ-KJ 09NA
Wireless Signal Receiver
Wireless Remote Controller
Wired Remote Controller
Remote Sensor
Interface
15NA
MLZ-KP 18NA
09NA
12NA
SLZ-KF 18NA
09NA
12NA
15NA
18NA
Wireless Signal Receiver
PAR-SA9CA-E
Wireless Signal Receiver
PAR-FA32MA-W
●
●
●
●
Wireless Signal Receiver
PAR-FA32MA-E
●
●
●
●
Wireless Remote Receiver Panel
PAR-SF9FA-E
●
●
●
●
Wireless Remote Receiver Panel
PAR-SR3LA-E
Remote Controller Holder
U01A01083
Wireless Remote Controller
PAR-SL100A-E
●
●
●
●
Wireless Remote Controller
PAR-FL32MA-E
Controller Kit (Sender & Receiver)
PAR-SL93B-E
Controller Kit with i-see Sensor™
PAR-SA92MW-E
kumo touch™ Backlit, Wall-mounted, Wireless Controller
MHK2
Deluxe MA Remote Controller Simple MA Controller
●
●
●
●
●
●
●
●
●
●
●
PAR-40MAAU
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●
●
●
●
PAC-YT53CRAU-J
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●
●
●
●
Touch MA Controller
PAR-CT01MAU-SB
●*1
●*1
●*1
●*1
●*1
●*1
●*1
●
●
●
●
Airzone ZBS Wired Blueface Principal Controller White
AZZBSBLUEFACECB
Airzone ZBS Wired Think Controller White
AZZBSTHINKCB
Airzone ZBS Wireless Think Controller White
AZZBSTHINKRB
Airzone ZBS Wired Lite Controller White
AZZBSLITECB
Airzone ZBS Wireless Lite Controller White
AZZBSLITERB ●
●
●
●
●
●
●
●
Wired Remote Sensor
PAC-SE41TS-E
Wired Remote Sensor
M21EAA307
●
●
●
●
●
●
●
Wireless Temperature and Humidity Sensor
PAC-USWHS003-TH-1
●
●
●
●
●
●
●
●
●
●
●
●*3
●*3
●*3
●*3
●*3
●*3
●*3
●
●
●
●
Flush Mount Remote Temperature Sensor
PAC-USSEN001-FM-1
System Control Interface
MAC-3334F-E
Wireless Interface 2
PAC-USWHS002-WF-2
●
●
●
●
●
●
●
●
●
●
●
Thermostat Interface
PAC-US444CN-1
●
●
●
●
●
●
●
●
●
●
●
kumo station®
PAC-WHS01HC-E
●
●
●
●
●
●
●
●
●
●
●
USNAP Interface
PAC-WHS01UP-E
●
●
●
●
●
●
●
●
●
●
●
IT Extender
PAC-WHS01IE-E
●
●
●
●
●
●
●
●
●
●
●
BACnet®and MODBUS® Interface
PAC-UKPRC001-CN-1
●
●
●
●
●
●
●
●
●
●
●
External Fan / Heater Control Relay Adapter
CN24RELAY-KIT-CM3
●
●
●
●
●
●
●
●
●
●
●
Wire for Remote on/off with CN32 connector
PAC-715AD
●
●
●
●
Connector and wire for Operation status/error using CN51
PAC-725AD
●
●
●
●
Connector cable for remote display
PAC-SA88HA-EP
●
●
●
●
Connector for CN32 (remote on/off)
PAC-SE55RA-E
●
●
●
●
Lockdown Bracket for Hand-held Remote Controllers
RCMKP1CB
Remote Operation Adapter
PAC-SF40RM-E
●*2
●*2
●*2
●*2
●*1 (requires MAC-334IF-E), ●*2 Unable to use with wireless remote controller ●*3 Allows indoor units to connect to an MA contoller
144
12NA
4-way Ceiling Cassette
●
●
●
●
●
●
●
Horizontal-ducted
Multi-position Air Handler
SEZ-KD
Wall Mount
SVZ-KP
09NA4
12NA4
15NA4
18NA4
●
●
●
●
●
●
●
●
●
●
●
●
●
Ceiling-suspended
PKA
PCA-
12NA
18NA
24NA
30NA
36NA
A12HA7
A18HA7
A24KA7
A30KA7
A36KA7
A24KA7
A30KA7
A36KA7
A42KA7
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
● ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●*2
●*2
●*2
●*2
●*2
●*2
●*2
●*2
●*2
●
●
●
●
●
●
●
●
●
●
145
Optional Parts List for Controllers 4-way Ceiling Cassette PLA-
Wireless Signal Receiver
Wireless Remote Controller
Wired Remote Controller
Remote Sensor
Interface
A18EA7
A24EA7
A30EA7
A36EA7
A42EA7
Wireless Signal Receiver
PAR-SA9CA-E
Wireless Signal Receiver
PAR-FA32MA-W
●
●
●
●
●
●
Wireless Signal Receiver
PAR-FA32MA-E
●
●
●
●
●
●
Wireless Remote Receiver Panel
PAR-SF9FA-E ●
●
●
●
●
●
Wireless Remote Receiver Panel
PAR-SR3LA-E
Remote Controller Holder
U01A01083
Wireless Remote Controller
PAR-SL100A-E
Wireless Remote Controller
PAR-FL32MA-E
Controller Kit (Sender & Receiver)
PAR-SL93B-E
Controller Kit with i-see Sensor™
PAR-SA92MW-E
kumo touch™ Backlit, Wall-mounted, Wireless Controller
MHK2
●
●
●
●
●
●
Deluxe MA Remote Controller
PAR-40MAAU
●
●
●
●
●
●
Simple MA Controller
PAC-YT53CRAU-J
●
●
●
●
●
●
Touch MA Controller
PAR-CT01MAU-SB
●
●
●
●
●
●
Airzone ZBS Wired Blueface Principal Controller White
AZZBSBLUEFACECB
Airzone ZBS Wired Think Controller White
AZZBSTHINKCB
Airzone ZBS Wireless Think Controller White
AZZBSTHINKRB
Airzone ZBS Wired Lite Controller White
AZZBSLITECB
Airzone ZBS Wireless Lite Controller White
AZZBSLITERB ●
●
●
●
●
●
Wired Remote Sensor
PAC-SE41TS-E
Wired Remote Sensor
M21EAA307
Wireless Temperature and Humidity Sensor
PAC-USWHS003-TH-1
●
●
●
●
●
●
●
●
●
●
●
●
Flush Mount Remote Temperature Sensor
PAC-USSEN001-FM-1
System Control Interface
MAC-3334F-E
Wireless Interface 2
PAC-USWHS002-WF-2
●
●
●
●
●
●
Thermostat Interface
PAC-US444CN-1
●
●
●
●
●
●
kumo station®
PAC-WHS01HC-E
●
●
●
●
●
●
USNAP Interface
PAC-WHS01UP-E
●
●
●
●
●
●
IT Extender
PAC-WHS01IE-E
●
●
●
●
●
●
BACnet®and MODBUS® Interface
PAC-UKPRC001-CN-1
●
●
●
●
●
●
External Fan / Heater Control Relay Adapter
CN24RELAY-KIT-CM3
●
●
●
●
●
●
Wire for Remote on/off with CN32 connector
PAC-715AD
Connector and wire for Operation status/error using CN51
PAC-725AD
Connector cable for remote display
PAC-SA88HA-EP
Connector for CN32 (remote on/off)
PAC-SE55RA-E
●
●
●
●
●
●
Lockdown Bracket for Hand-held Remote Controllers
RCMKP1CB
Remote Operation Adapter
PAC-SF40RM-E
●*1 (requires MAC-334IF-E), ●*2 Unable to use with wireless remote controller ●*3 Allows indoor units to connect to an MA controller
146
A12EA7
●
●
●
●
●
●
●*2
●*2
●*2
●*2
●*2
●*2
Ceiling-conceald
Multi-position Air Handler
PEAD-
PVA-
A09AA7
A12AA7
A15AA7
A18AA7
A24AA7
A30AA7
A36AA7
A42AA7
A12AA7
A18AA7
A24AA7
A30AA7
A36AA7
A42AA7
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●*2
●*2
●*2
●*2
●*2
●*2
●
●
●
●
●
●
●
●
●*2
●*2
●*2
●*2
●*2
●*2
●*2
●*2
147
Additional M-Series Information Port Adapters Parts Numbers Model Name
Diameter A
Diameter B
MAC-A454JP-E
3/8"
1/2"
MAC-A455JP-E
1/2"
3/8"
MAC-A456JP-E
1/2"
5/8"
PAC-SG76RJ-E
3/8"
5/8"
ADP5834
5/8"
3/4"
PAC-493PI
1/4"
3/8"
Diameter A = Female
Multi-zone Efficiency Ratings Model
MXZ-2C20NA2
MXZ-3C24NA2
MXZ-3C30NA2
MXZ-4C36NA2
MXZ-5C42NA2
MXZ-8C48NA2
MXZ-8C60NA2
MXZ-2C20NAHZ2
MXZ-3C24NAHZ2
MXZ-3C30NAHZ2
MXZ-4C36NAHZ2
MXZ-5C42NAHZ2
MXZ-8C48NAHZ2
148
SEER
EER
HSPF
Ducted
Configuration
16.00
10.00
9.30
Mixed
18.00
11.35
9.65
Non-Ducted
20.00
12.70
10.00
Ducted
16.00
11.20
9.20
Mixed
18.00
12.40
9.50
Non-Ducted
20.00
13.60
9.80
Ducted
16.20
9.60
9.60
Mixed
17.60
10.10
10.10
Non-Ducted
19.00
10.60
10.60
Ducted
16.00
8.70
9.80
Mixed
17.60
9.05
10.40
Non-Ducted
19.20
9.40
11.00
Ducted
15.20
9.00
9.10
Mixed
17.45
9.10
9.70
Non-Ducted
19.70
9.20
10.30
Ducted
16.00
10.00
10.10
Mixed
18.00
11.10
10.80
Non-Ducted
20.00
12.20
11.50
Ducted
17.00
10.00
10.70
Mixed
18.20
11.20
10.70
Non-Ducted
19.50
12.50
10.70
Ducted
15.00
11.00
9.50
Mixed
16.00
12.25
9.65
Non-Ducted
17.00
13.50
9.80
Ducted
15.50
10.00
9.00
Mixed
17.25
11.75
9.50
Non-Ducted
19.00
13.50
10.00
Ducted
16.00
10.30
9.80
Mixed
17.00
11.40
10.40
Non-Ducted
18.00
12.50
11.00
Ducted
17.50
12.50
11.00
Mixed
18.70
13.20
11.10
Non-Ducted
20.00
14.00
11.30
Ducted
17.00
10.80
10.60
Mixed
18.50
12.20
10.80
Non-Ducted
20.00
13.40
11.00
Ducted
16.00
10.00
10.10
Mixed
18.00
11.10
10.80
Non-Ducted
20.00
12.20
11.50
Diameter B = Male
M-Series Air Outlet Coverage Range* Model MSZ-FH06NA, MSZ-FH09NA MSZ-FH12NA MSZ-FH15NA MSZ-FH18NA2 MSZ-GL06NA, MSZ/Y-GL09NA, MSZ/Y-GL12NA MSZ/Y-GL15NA MSZ/Y-GL18NA MSZ/Y-GL24NA MSZ/Y-D30NA, MSZ/Y-D36NA MFZ-KJ09NA, MFZ-KJ12NA MFZ-KJ15NA MFZ-KJ18NA SLZ-KF09NA SLZ-KF12NA SLZ-KF15NA SLZ-KF18NA MSZ-EF09NAW(B)(S) MSZ-EF12NAW(B)(S) MSZ-EF15NAW(B)(S) MSZ-EF18NAW(B)(S) MSZ-HM09NA, MSZ-HM12NA MSZ-HM15NA MSZ-HM18NA MSZ-HM24NA MSZ-JP09WA MSZ-JP12WA MSZ-WR09NA MSZ-WR12NA MSZ-WR18NA MSZ-WR24NA MLZ-KP09NA MLZ-KP12NA MLZ-KP18NA
Mode
Function
Airflow (CFM)
HEAT
DRY
437
Coverage (FT) 29.8
COOL
WET
328
22.5
HEAT
DRY
454
31.0
COOL
WET
342
23.5
HEAT
DRY
497
33.8
COOL
WET
354
24.1
HEAT
DRY
514
34.9
COOL
WET
395
27.0
HEAT
DRY
406
29.5
COOL
WET
286
21.0
HEAT
DRY
463
33.5
COOL
WET
385
28.0
HEAT
DRY
646
44.0
COOL
WET
581
39.7
HEAT
DRY
738
36.9
COOL
WET
661
33.2
HEAT
DRY
848
45.0
COOL
WET
763
40.7
HEAT
DRY
417
29.6
COOL
WET
354
25.3
HEAT
DRY
470
33.3
COOL
WET
366
26.2
HEAT
DRY
470
33.3
COOL
WET
417
29.7
HEAT
DRY
300
15.1
COOL
WET
270
13.7
HEAT
DRY
336
16.9
COOL
WET
302
15.2
HEAT
DRY
405
20.3
COOL
WET
365
18.3
HEAT
DRY
475
23.7
COOL
WET
429
21.4
HEAT
DRY
420
29.2
COOL
WET
319
22.3
HEAT
DRY
448
31.1
COOL
WET
319
22.3
HEAT
DRY
448
31.1
COOL
WET
313
21.9
HEAT
DRY
466
32.3
COOL
WET
334
23.4
HEAT
DRY
406
29.5
COOL
WET
286
21.0
HEAT
DRY
463
33.5
COOL
WET
385
28.0
HEAT
DRY
625
42.6
COOL
WET
562
38.4
HEAT
DRY
702
47.7
COOL
WET
632
43.1
HEAT
DRY
406
29.5
COOL
WET
364
26.5
HEAT
DRY
406
29.5
COOL
WET
364
26.5
HEAT
DRY
406
29.5
COOL
WET
286
21.0
HEAT
DRY
406
29.5
COOL
WET
286
21.0
HEAT
DRY
625
42.6
COOL
WET
562
38.4
HEAT
DRY
702
47.7
COOL
WET
632
43.1
HEAT
DRY
311
20.7
COOL
WET
325
21.7
HEAT
DRY
332
22.1
COOL
WET
350
23.3
HEAT
DRY
403
26.7
COOL
WET
417
27.6
149
Heating Capacity Outdoor Temperature Degrees (ยบ F) MSZ-FH06NA/MUZ-FH06NA
MSZ-FH09NA/MUZ-FH09NA
MSZ-FH12NA/MUZ-FH12NA
MSZ-FH15NA/MUZ-FH15NA
MSZ-FH18NA2/MUZ-FH18NA2
MSZ-FH06NA/MUZ-FH06NAH
MSZ-FH09NA/MUZ-FH09NAH
MSZ-FH12NA/MUZ-FH12NAH
MSZ-FH15NA/MUZ-FH15NAH
MSZ-FH18NA2/MUZ-FH18NA2H
MSZ-GL09NA/MUZ-GL09NA
MSZ-GL12NA/MUZ-GL12NA
MSZ-GL15NA/MUZ-GL15NA
MSZ-GL18NA/MUZ-GL18NA
MSZ-GL24NA/MUZ-GL24NA
MSZ-HM09NA/MUZ-HM09NA
MSZ-HM12NA/MUZ-HM12NA
MSZ-HM15NA/MUZ-HM15NA
MSZ-HM18NA/MUZ-HM18NA
MSZ-HM24NA/MUZ-HM24NA
MSZ-D30NA/MUZ-D30NA
MSZ-D36NA/MUZ-D36NA
MSZ-JP09NA/MUZ-JP09NA
MSZ-JP12NA/MUZ-JP12NA
MSZ-WR09NA/MUZ-WR09NA
MSZ-WR12NA/MUZ-WR12NA
MSZ-WR18NA/MUZ-WR18NA
MSZ-WR24NA/MUZ-WR24NA
MFZ-KJ09NA/MUFZ-KJ09NAHZ
150
50
41.0
32.0
23.0
14.0
5.0
-4
-13 6,430
Heating Capacity (Btu/h)
8,700
8,700
8,700
8,700
8,700
8,700
7,650
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
88%
74%
Heating Capacity (Btu/h)
10,900
10,900
10,900
10,900
10,900
10,900
9,260
7,630
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
85%
70%
Heating Capacity (Btu/h)
13,600
13,600
13,600
13,600
13,600
13,600
11,690
9,920
Percentage of Rated Capacity Heating Capacity (Btu/h)
100%
100%
100%
100%
100%
100%
86%
73%
18,000
18,000
18,000
18,000
18,000
18,000
16,200
14,580
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
90%
81%
Heating Capacity (Btu/h)
20,300
20,300
20,300
20,300
20,300
20,300
17,250
14,210
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
85%
70%
Heating Capacity (Btu/h)
8,700
8,700
8,700
8,700
8,700
8,700
7,650
6,430
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
88%
74%
Heating Capacity (Btu/h)
10,900
10,900
10,900
10,900
10,900
10,900
9,370
7,950
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
86%
73%
Heating Capacity (Btu/h)
13,600
13,600
13,600
13,600
13,600
13,600
11,690
9,920
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
86%
73%
Heating Capacity (Btu/h)
18,000
18,000
18,000
18,000
18,000
18,000
16,200
14,580
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
90%
81%
Heating Capacity (Btu/h)
20,300
20,300
20,300
20,300
20,300
20,300
17,250
14,210 70%
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
85%
Heating Capacity (Btu/h)
10,900
10,900
10,900
10,460
9,480
8,170
6,860
-
Percentage of Rated Capacity
100%
100%
100%
96%
87%
75%
63%
0%
Heating Capacity (Btu/h)
14,400
14,400
14,110
12,960
11,660
9,790
7,920
-
Percentage of Rated Capacity
100%
100%
98%
90%
81%
68%
55%
0%
Heating Capacity (Btu/h)
18,000
17,100
16,920
16,920
16,200
13,680
11,160
-
Percentage of Rated Capacity
100%
95%
94%
94%
90%
76%
62%
0%
Heating Capacity (Btu/h)
21,600
21,600
21,600
19,440
17,060
14,900
12,520
-
Percentage of Rated Capacity
100%
100%
100%
90%
79%
69%
58%
0%
Heating Capacity (Btu/h)
27,600
27,600
27,600
26,220
23,460
19,320
15,450
-
Percentage of Rated Capacity
100%
100%
100%
95%
85%
70%
56%
0%
Heating Capacity (Btu/h)
10,900
10,570
9,480
8,500
7,300
5,990
4,680
-
Percentage of Rated Capacity
100%
97%
87%
78%
67%
55%
43%
0%
Heating Capacity (Btu/h)
12,200
12,200
11,220
10,120
9,020
7,440
5,850
-
Percentage of Rated Capacity
100%
100%
92%
83%
74%
61%
48%
0%
Heating Capacity (Btu/h)
18,000
15,300
14,940
14,400
13,680
12,240
10,620
-
Percentage of Rated Capacity
100%
85%
83%
80%
76%
68%
59%
0%
Heating Capacity (Btu/h)
18,000
18,000
18,000
16,560
14,580
12,780
10,980
-
Percentage of Rated Capacity
100%
100%
100%
92%
81%
71%
61%
0%
Heating Capacity (Btu/h)
26,000
24,440
22,360
20,020
17,680
15,600
13,260
-
Percentage of Rated Capacity
100%
94%
86%
77%
68%
60%
51%
0%
Heating Capacity (Btu/h)
32,600
28,030
25,420
22,820
19,880
-
-
-
Percentage of Rated Capacity
100%
86%
78%
70%
61%
0%
0%
0%
Heating Capacity (Btu/h)
35,200
29,560
27,450
25,340
22,880
-
-
-
Percentage of Rated Capacity
100%
84%
78%
72%
65%
0%
0%
0%
Heating Capacity (Btu/h)
10,900
10,570
9,480
8,500
7,300
5,990
4,680
-
Percentage of Rated Capacity
100%
97%
87%
78%
67%
55%
43%
0%
Heating Capacity (Btu/h)
12,200
12,200
11,220
10,120
9,020
7,440
5,850
-
Percentage of Rated Capacity
100%
100%
92%
83%
74%
61%
48%
0%
Heating Capacity (Btu/h)
10,900
10,570
9,480
8,500
7,300
5,990
-
-
Percentage of Rated Capacity
100%
97%
87%
78%
67%
55%
0%
0%
Heating Capacity (Btu/h)
12,200
12,200
11,220
10,120
9,020
7,440
-
-
Percentage of Rated Capacity
100%
100%
92%
83%
74%
61%
0%
0%
Heating Capacity (Btu/h)
18,000
18,000
18,000
16,560
14,580
12,780
-
-
Percentage of Rated Capacity
100%
100%
100%
92%
81%
71%
0%
0%
Heating Capacity (Btu/h)
26,000
24,440
22,360
20,020
17,680
15,600
-
-
Percentage of Rated Capacity
100%
94%
86%
77%
68%
60%
0%
0%
Heating Capacity (Btu/h)
11,000
11,000
11,000
11,000
11,000
11,000
9,130
7,260
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
83%
66%
Heating Capacity Outdoor Temperature Degrees (ยบ F) MFZ-KJ12NA/MUFZ-KJ12NAHZ
MFZ-KJ15NA/MUFZ-KJ15NAHZ
MFZ-KJ18NA/MUFZ-KJ18NAHZ
MLZ-KP09NA/SUZ-KA09NA2
MLZ-KP12NA/SUZ-KA12NA2
MLZ-KP18NA/SUZ-KA18NA2
SLZ-KF09NA/SUZ-KA09NA2
SLZ-KF12NA/SUZ-KA12NA2
SLZ-KF15NA/SUZ-KA15NA2
SLZ-KF18NA/SUZ-KA18NA2
SEZ-KD09NA4/SUZ-KA09NA2
SEZ-KD12NA4/SUZ-KA12NA2
SEZ-KD15NA4/SUZ-KA15NA2
SEZ-KD18NA4/SUZ-KA18NA2
PEAD-A09AA7/SUZ-KA09NA2
PEAD-A12AA7/SUZ-KA12NA2
PEAD-A15AA7/SUZ-KA15NA2
PEAD-A18AA7/SUZ-KA18NA2
PEAD-A24AA7/SUZ-KA24NA2
PEAD-A30AA7/SUZ-KA30NA2
PEAD-A36AA7/SUZ-KA36NA2
SVZ-KP12NA/SUZ-KA12NA2
SVZ-KP18NA/SUZ-KA18NA2
SVZ-KP24NA/SUZ-KA24NA2
SVZ-KP30NA/SUZ-KA36NA2
SVZ-KP36NA/SUZ-KA36NA2
MXZ-2C20NA2
MXZ-3C24NA2
MXZ-3C30NA2
Heating Capacity (Btu/h)
50
41.0
32.0
23.0
14.0
5.0
-4
-13
13,000
13,000
13,000
13,000
13,000
13,000
10,790
8,450
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
83%
65%
Heating Capacity (Btu/h)
18,000
18,000
18,000
18,000
18,000
18,000
14,940
13,860
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
83%
77%
Heating Capacity (Btu/h)
21,000
21,000
21,000
21,000
21,000
21,000
18,480
15,960 76%
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
88%
Heating Capacity (Btu/h)
12,000
10,620
9,230
7,840
6,450
5,090
3,770
-
Percentage of Rated Capacity
100%
89%
77%
65%
54%
42%
31%
0%
Heating Capacity (Btu/h)
15,400
13,630
11,850
10,060
8,280
6,540
4,840
-
Percentage of Rated Capacity
100%
89%
77%
65%
54%
42%
31%
0%
Heating Capacity (Btu/h)
20,000
17,700
15,390
13,060
10,760
8,490
6,290
-
Percentage of Rated Capacity
100%
89%
77%
65%
54%
42%
31%
0%
Heating Capacity (Btu/h)
11,000
9,730
8,460
7,180
5,920
4,670
3,460
-
Percentage of Rated Capacity
100%
89%
77%
65%
54%
42%
31%
0%
Heating Capacity (Btu/h)
13,000
11,510
10,000
8,490
6,990
5,520
4,080
-
Percentage of Rated Capacity
100%
89%
77%
65%
54%
42%
31%
0%
Heating Capacity (Btu/h)
18,000
15,930
13,850
11,760
9,680
7,640
5,660
-
Percentage of Rated Capacity
100%
89%
77%
65%
54%
42%
31%
0%
Heating Capacity (Btu/h)
19,700
17,440
15,150
12,870
10,600
8,370
6,190
-
Percentage of Rated Capacity
100%
89%
77%
65%
54%
42%
31%
0%
Heating Capacity (Btu/h)
12,000
10,620
9,230
7,840
6,450
5,090
3,770
-
Percentage of Rated Capacity
100%
89%
77%
65%
54%
42%
31%
0%
Heating Capacity (Btu/h)
15,000
13,280
11,540
9,800
8,070
6,370
4,710
-
Percentage of Rated Capacity
100%
89%
77%
65%
54%
42%
31%
0%
Heating Capacity (Btu/h)
18,000
15,930
13,850
11,760
9,680
7,640
5,660
-
Percentage of Rated Capacity
100%
89%
77%
65%
54%
42%
31%
0%
Heating Capacity (Btu/h)
21,600
19,120
16,620
14,110
11,620
9,170
6,790
-
Percentage of Rated Capacity
100%
89%
77%
65%
54%
42%
31%
0%
Heating Capacity (Btu/h)
12,000
10,620
9,230
7,840
6,450
5,090
3,770
-
Percentage of Rated Capacity
100%
89%
77%
65%
54%
42%
31%
0%
Heating Capacity (Btu/h)
15,000
13,280
11,540
9,800
8,070
6,370
4,710
-
Percentage of Rated Capacity
100%
89%
77%
65%
54%
42%
31%
0%
Heating Capacity (Btu/h)
18,000
15,930
13,850
11,760
9,680
7,640
5,660
-
Percentage of Rated Capacity
100%
89%
77%
65%
54%
42%
31%
0%
Heating Capacity (Btu/h)
21,600
19,120
16,620
14,110
11,620
9,170
6,790
-
Percentage of Rated Capacity
100%
89%
77%
65%
54%
42%
31%
0%
Heating Capacity (Btu/h)
25,000
22,130
19,230
16,330
13,450
-
-
-
Percentage of Rated Capacity
100%
89%
77%
65%
54%
0%
0%
0%
Heating Capacity (Btu/h)
30,000
26,560
23,080
19,600
16,140
-
-
-
Percentage of Rated Capacity
100%
89%
77%
65%
54%
0%
0%
0%
Heating Capacity (Btu/h)
33,500
29,660
25,770
21,890
18,030
-
-
-
Percentage of Rated Capacity
100%
89%
77%
65%
54%
0%
0%
0%
Heating Capacity (Btu/h)
15,000
13,280
11,540
9,800
8,070
6,370
4,710
-
Percentage of Rated Capacity
100%
89%
77%
65%
54%
42%
31%
0%
Heating Capacity (Btu/h)
21,600
19,120
16,620
14,110
11,620
9,170
6,790
-
Percentage of Rated Capacity
100%
89%
77%
65%
54%
42%
31%
0%
Heating Capacity (Btu/h)
25,000
22,130
19,230
16,330
13,450
-
-
-
Percentage of Rated Capacity
100%
89%
77%
65%
54%
0%
0%
0%
Heating Capacity (Btu/h)
30,000
26,560
23,080
19,600
16,140
-
-
-
Percentage of Rated Capacity
100%
89%
77%
65%
54%
0%
0%
0%
Heating Capacity (Btu/h)
33,500
29,660
25,770
21,890
18,030
-
-
-
Percentage of Rated Capacity
100%
89%
77%
65%
54%
0%
0%
0%
Heating Capacity (Btu/h)
22,000
22,000
18,920
15,840
12,980
9,900
-
-
Percentage of Rated Capacity
100%
100%
86%
72%
59%
45%
0%
0%
Heating Capacity (Btu/h)
25,000
25,000
24,000
20,750
17,250
13,250
-
-
Percentage of Rated Capacity
100%
100%
96%
83%
69%
53%
0%
0%
Heating Capacity (Btu/h)
28,600
28,600
28,020
24,310
20,300
15,730
-
-
Percentage of Rated Capacity
100%
100%
98%
85%
71%
55%
0%
0%
151
Heating Capacity Outdoor Temperature Degrees (ยบ F) MXZ-4C36NA2
MXZ-5C42NA2
MXZ-8C48NA2
MXZ-8C60NA2
MXZ-2C20NAHZ2
MXZ-3C24NAHZ2
MXZ-3C30NAHZ2
MXZ-4C36NAHZ2
MXZ-5C42NAHZ2
MXZ-8C48NAHZ2
MLZ-KP09NA/SUZ-KA09NAHZ
MLZ-KP12NA/SUZ-KA12NAHZ
MLZ-KP18NA/SUZ-KA18NAHZ
SLZ-KF09NA/SUZ-KA09NAHZ
SLZ-KF12NA/SUZ-KA12NAHZ
SLZ-KF15NA//SUZ-KA15NAHZ
SLZ-KF18NA/SUZ-KA18NAHZ
SEZ-KD09NA4/SUZ-KA09NAHZ
SEZ-KD12NA4/SUZ-KA12NAHZ
SEZ-KD15NA4/SUZ-KA15NAHZ
SEZ-KD18NA4/SUZ-KA18NAHZ
PEAD-A09AA7/SUZ-KA09NAHZ
PEAD-A12AA7/SUZ-KA12NAHZ
PEAD-A15AA7/SUZ-KA15NAHZ
PEAD-A18AA7/SUZ-KA18NAHZ
SVZ-KP12NA/SUZ-KA12NAHZ
SVZ-KP18NA/SUZ-KA18NAHZ
152
50
41.0
32.0
23.0
14.0
5.0
-4
-13
Heating Capacity (Btu/h)
36,000
36,000
33,480
29,160
24,120
18,720
-
-
Percentage of Rated Capacity
100%
100%
93%
81%
67%
52%
0%
0%
Heating Capacity (Btu/h)
45,000
45,000
41,850
36,450
30,150
23,400
-
-
Percentage of Rated Capacity
100%
100%
93%
81%
67%
52%
0%
0%
Heating Capacity (Btu/h)
54,000
54,000
52,920
44,820
36,180
32,400
28,620
-
Percentage of Rated Capacity
100%
100%
98%
83%
67%
60%
53%
0% 29,040
Heating Capacity (Btu/h)
66,000
66,000
66,000
56,100
44,880
39,600
34,320
Percentage of Rated Capacity
100%
100%
100%
85%
68%
60%
52%
44%
Heating Capacity (Btu/h)
22,000
22,000
22,000
22,000
22,000
22,000
21,120
20,460
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
96%
93%
Heating Capacity (Btu/h)
25,000
25,000
25,000
25,000
25,000
25,000
23,750
22,500
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
95%
90%
Heating Capacity (Btu/h)
28,600
28,600
28,600
28,600
28,600
28,600
26,880
25,160
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
94%
88%
Heating Capacity (Btu/h)
45,000
45,000
45,000
45,000
45,000
45,000
39,600
33,750
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
88%
75%
Heating Capacity (Btu/h)
48,000
48,000
48,000
48,000
48,000
48,000
42,240
36,000
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
88%
75%
Heating Capacity (Btu/h)
54,000
54,000
54,000
54,000
54,000
54,000
47,520
40,500
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
88%
75%
Heating Capacity (Btu/h)
12,000
12,000
12,000
12,000
12,000
12,000
10,320
9,120
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
86%
76%
Heating Capacity (Btu/h)
15,000
15,000
15,000
15,000
15,000
15,000
12,900
11,400
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
86%
76%
Heating Capacity (Btu/h)
18,600
18,600
18,600
18,600
18,600
18,600
15,996
14,136
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
86%
76%
Heating Capacity (Btu/h)
11,000
11,000
11,000
11,000
11,000
11,000
9,460
8,360
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
86%
76%
Heating Capacity (Btu/h)
13,800
13,800
13,800
13,800
13,800
13,800
11,868
10,488
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
86%
76%
Heating Capacity (Btu/h)
16,400
16,400
16,400
16,400
16,400
16,400
14,104
12,464
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
86%
76%
Heating Capacity (Btu/h)
18,800
18,800
18,800
18,800
18,800
18,800
16,168
14,288
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
86%
76%
Heating Capacity (Btu/h)
12,500
12,500
12,500
12,500
12,500
12,500
10,750
9,500
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
86%
76%
Heating Capacity (Btu/h)
15,000
15,000
15,000
15,000
15,000
15,000
12,900
11,400
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
86%
76%
Heating Capacity (Btu/h)
18,000
18,000
18,000
18,000
18,000
18,000
15,480
13,680
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
86%
76%
Heating Capacity (Btu/h)
21,600
21,600
21,600
21,600
21,600
21,600
18,576
16,416
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
86%
76%
Heating Capacity (Btu/h)
12,000
12,000
12,000
12,000
12,000
12,000
10,320
9,120
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
86%
76%
Heating Capacity (Btu/h)
15,000
15,000
15,000
15,000
15,000
15,000
12,900
11,400
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
86%
76%
Heating Capacity (Btu/h)
18,000
18,000
18,000
18,000
18,000
18,000
15,480
13,680
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
86%
76%
Heating Capacity (Btu/h)
21,600
21,600
21,600
21,600
21,600
21,600
18,576
16,416
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
86%
76%
Heating Capacity (Btu/h)
15,000
15,000
15,000
15,000
15,000
15,000
12,900
11,400
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
86%
76%
Heating Capacity (Btu/h)
21,600
21,600
21,600
21,600
21,600
21,600
18,576
16,416
Percentage of Rated Capacity
100%
100%
100%
100%
100%
100%
86%
76%
153
Additional P-Series Information Outlet Air Speed and Coverage Range* Model
AIRFLOW (CFM)
AIR SPEED (FT/SEC)
COVERAGE RANGE (FT)
PLA-A12EA7
530
7.8
13
PLA-A18EA7
600
8.8
14
PLA-A24EA7
810
11.9
19
PLA-A30EA7
880
12.9
21
PLA-A36EA7
1200
17.6
28
PLA-A42EA7
1200
17.6
28
PKA-A12HA7
425
20.0
35
PKA-A18HA7
425
20.0
35
PKA-A24KA7
775
19.7
47
PKA-A30KA7
775
19.7
47
PKA-A36KA7
920
22.3
53
PCA-A24KA7
670
10.2
32
PCA-A30KA7
705
10.5
33
PCA-A36KA7
990
11.8
41
PCA-A42KA7
1,025
12.1
42
*Air coverage represents the distance with 0.8 ft/sec air speed when blowing out horizontally from the unit operating at the high fan speed. This is a general guideline; actual coverage depends on size and layout of the room.
154
155
Correction Factors:
Cooling Correction Factors: PUY
Cooling Piping Correction Factors: PUY
156
Cooling Correction Factors: PUZ
Heating Correction Factors: PUZ
157
Correction Factors:
Cooling Piping Correction Factors: PUZ
158
Cooling Correction Factors: PUZ-HA
Heating Correction Factors: PUZ-HA
159
External Dimensions: M-Series
MSZ-FH06NA MSZ-FH09NA MSZ-FH12NA MSZ-FH15NA MSZ-FH18NA MSZ-FH18NA2
INDOOR UNIT
12
INDOOR UNIT
Unit : inch
MSZ-EF09NA(W)(B)(S) MSZ-EF12NA(W)(B)(S) MSZ-EF15NA(W)(B)(S) MSZ-EF18NA(W)(B)(S)
MSZ-GL06NA MSZ-GL09NA MSY-GL09NA MSZ-GL12NA MSY-GL12NA MSZ-GL15NA MSY-GL15NA
MSZ-GL18NA MSY-GL18NA INDOOR UNIT
INDOOR UNIT
36-5/16 35-13/16 1/4
12
Air in Installation plate
3-15/16
1/4
2-1/16
Piping
6-5/16
27-15/16
4-1/2
2-9/16 3-11/16
2-13/16
2-1/2
160
2-1/16
Air out
2-9/16
5-3/4
2-9/16
Drain hose 2-9/16
M-Series
MSZ-GL24NA MSY-GL24NA
Unit : inch
MSZ-D30NA MSY-D30NA MSZ-D36NA MSY-D36NA
INDOOR UNIT
INDOOR UNIT
45-1/2
11-5/8
Air in
46-1/16
1/4 Installation plate
33-11/16
9-1/2 2-5/8
Air out
MSZ-HM18NA MSZ-HM24NA
MSZ-WR18NA MSZ-WR24NA
5-7/8
INDOOR UNIT
36-5/16 35-13/16 1/4
Air in
12
Installation plate
3-15/16
1/4
2-1/16
Piping
6-5/16
27-15/16
4-1/2 Air out
2-9/16
2-9/16 3-11/16
2-9/16
Drain hose 2-9/16
5-3/4
2-13/16
INDOOR UNIT
2-1/2
MSZ-JP09WA MSZ-JP12WA MSZ-WR09NA MSZ-WR12NA
2-1/16
MSZ-HM09NA MSZ-HM12NA MSZ-HM15NA
Drain hose
2-15/16
2-15/16
2-1/2
14-3/8
Piping
161
M-Series
Unit : inch/cm
MVZ-A12AA7 MVZ-A18AA7 MVZ-A24AA7 MVZ-A30AA7 MVZ-A36AA7
Unit:mm(in.)
Top view
INDOOR UNIT
1
2
Terminal block Top (Remote controller transmission) Terminal block ø26 Knockout Hole C (Indoor / Outdoor unit connection) Front Air outlet (Remote controller Control box Note 1.Keep theview service space for maintenance at the front. transmission) 8(3/8) ø2643(1-3/4) Knockout Hole Primary drain pipe Top (Remote controller (Gravity drain) transmission) ø19.05(3/4) 3/4"FPT Primary drain pipe (Gravity drain) drain pipe Secondary 8(3/8) ø19.05(3/4) 3/4"FPT (Emergency draining)
(Emergency draining) ø19.05(3/4) 3/4"FPT Secondary drain pipe Primary drain pipe (Emergency draining) Top (Gravity drain) ø19.05(3/4) 3/4"FPT ø19.05(3/4) 3/4"FPT view (Horizontal left) Primary drain pipe (Gravity drain) Hole ø26 Knockout ø19.05(3/4) 3/4"FPT (Horizontal left) unit (Indoor / Outdoor
B(Duct)
connection)
SVZ-KP12NA SVZ-KP18NA SVZ-KP24NA SVZ-KP30NA SVZ-KP36NA
A
Bottom
55(2-3/16) view
Duct Connection B
C
D
E
508 x 406.4 x 25.4 376 x 402 MVZ-A12AA7 281 224 1275 376 432 MVZ-A18AA7 Left (20 xside 16 x 1) (17) (14-13/16 x 15-7/8) (14-13/16) (11-1/8) (8-7/8) (50-1/4) view MVZ-A24AA7
(18-13/16 x 15-7/8)
Model A B C D MLZ-KP09NA MLZ-KP12NA MLZ-KP18NA SVZ-KP12NA
INDOOR UNIT SVZ-KP18NA SVZ-KP24NA SVZ-KP30NA SVZ-KP36NA
432 376 (17) Model (14-13/16) A B
281 (11-1/8) C D
MVZ-A12AA7 281 224 376 432 MVZ-A18AA7 (17) (14-13/16) (11-1/8) (8-7/8) 534 477 382.6 MVZ-A24AA7 (21) (18-13/16) MVZ-A30AA7 477 (15-1/8) 382.6 266.5 534 MVZ-A36AA7 (21) (18-13/16) (15-1/8) (10-1/2)
224 (8-7/8) E F
G
680 823 (26-13/16) (32-7/16)
H
J
(10-1/2) 1378 737
1
735.5 Air inlet 360 (29)A (14-3/16) 461 (18-3/16)
Gas pipe ø12.7 (1/2)
2
Liquid pipe ø6.35 (1/4) ø9.52
ø15.88
(3/8)
(5/8)
view
E 1,010.8 (39-13/16) G H
1275 680 823 735.5 (50-1/4) (26-13/16) (32-7/16) (29) 266.5 1,113.8
(43-7/8) 953.5 792 (54-1/4) (29-1/16) (37-9/16) (31-3/16)
MLZ-KP09NA MLZ-KP12NA MLZ-KP18NA INDOOR UNIT
F
Primary drain pipe (Gravity drain) ø19.05(3/4) 3/4"FPT 36.8(1-1/2)
D
J
3 Air filter MVZ-A30AA7 534 477 382.6 266.5 1378 737 953.5 792 xMVZ-A36AA7 508 x 25.4(21) (18-13/16) 477 x 402 (15-1/8) (10-1/2) (54-1/4) (29-1/16) (37-9/16) (31-3/16) Bottom
508 (20 x 20 x 1)
Secondary drain pipe (Emergency draining) ø19.05(3/4) 3/4"FPT (Horizontal Right)
8(3/8) 30(1-3/16)
Secondary drain pipe (Emergency draining) ø19.05(3/4) 3/4"FPT
G H Model
13.2(9/16) 55(2-3/16) 50.8(2) 525.5(20-3/4) 8(3/8) 24(15/16) F
43(1-3/4)ø19.05(3/4) 3/4"FPT Primary drain pipe (Gravity drain) Control box ø19.05(3/4) 3/4"FPT (Remove Blower Panel)
F
G
680 36.8(1-1/2) 823 (26-13/16) (32-7/16) 1 Gas pipe 2 Liquid pipe J J
ø12.7 360 (1/2) (14-3/16) 737
ø15.88 (29-1/16)
461 (18-3/16)
(5/8)
ø6.35
(1/4)
953.5 ø9.52 (37-9/16) (3/8)
525.5(20-3/4) 8(3/8) F 470(18-9/16)E
Bottom
Nominal Filter Size
Primary drain pipe Control box Air inlet (Gravity drain)
Air filter
43(1-3/4) view 92(3-5/8)
Unit:mm(in.)
MFZ-KJ09N INDOOR
H
735.5 (29)
548(21-5/8) 402(15-7/8) (Duct)
Top
Terminal block (Indoor / Outdoor unit connection)
8(3/8)A 3
Left side view
Model
(Horizontal Right)
3/4"FPT
117.4 (4-5/8)
Front view
50.8(2)
ø19.05(3/4) 3/4"FPT ø19.05(3/4) Primary drain pipe (Gravity drain) ø19.05(3/4) 3/4"FPT (Horizontal left)
470(18-9/16)
70(2-13/16) 55(2-3/16)
G H
2-ø4.6 Burring Holes 43(1-3/4) for electric heat installation ø19.05(3/4) 3/4"FPT 30(1-3/16) 92(3-5/8) B(Duct) 1 Refrigerant piping 28.8(1-3/16) (Horizontal Right) flare connection(gas) Secondary drain pipe C 76(3) Primary drain pipe (Emergency draining) Air outlet 2 Refrigerant piping flare connection(liquid)ø19.05(3/4) 3/4"FPT (Gravity drain) ø26 Knockout Hole Secondary pipe ø19.05(3/4) drain 3/4"FPT (Indoor / Outdoor Secondary drain pipe draining) 55(2-3/16) D (Emergency Terminal block Secondary drain pipe (Emergency draining) unit connection) 3/4"FPT (Remote ø19.05(3/4) controller transmission) (Emergency draining)
ø26 Knockout77.8(3-1/8) Hole (Indoor Left/ Outdoor side unit connection) (Remoteview controller66(2-5/8) transmission)
Unit : inch/cm
55(2-3/16)
66(2-5/8)
548(21-5/8) 402(15-7/8) (Duct)
117.4 (4-5/8)
Front view
E
77.8(3-1/8)
70(2-13/16) 55(2-3/16)
(Indoor / Outdoor unit connection)
INDOOR UNIT
Refrigerant piping flareSecondary connection(liquid) drain pipe
24(15/16)
13.2(9/16)
ø26 Knockout Hole SVZ-KP12NA forø26 electrical heatHole wiring Knockout ø26 Knockout Hole (Remote controller transmission) (Indoor / Outdoor unit SVZ-KP18NA connection) 2-ø4.6 Burring Holes SVZ-KP24NA 2-ø4.6 Burring Holes for electric heat installation for electric heat installation SVZ-KP30NA Refrigerant piping B(Duct) 28.8(1-3/16) Refrigerant piping flareflare connection(gas) connection(gas) C 76(3) SVZ-KP36NA Refrigerant piping MVZ-A12AA7 MVZ-A18AA7 MVZ-A24AA7 MVZ-A30AA7 MVZ-A36AA7 Air outlet flare connection(liquid) ø26 Knockout Hole 2
INDOO
Note: Electrical entrance for SVZ located on both left and right side of the cabinet. See right or Left side view for knockout locations. Note 1.Keep the service space for maintenance at the front.
Top ø26 Knockout Hole view
1
MFZ-KJ0
ø26 Knockout Hole (Indoor / Outdoor unit ø26 Knockout Hole Bottom connection) (Remote controller (Remote controller transmission) transmission)
Right side view
Bottom Right side view
Model MVZ-A12AA7 MVZ-A18AA7 MVZ-A24AA7 Bottom MVZ-A30AA7 MVZ-A36AA7
J
3
Nominal Filter Size Duct Connection 508X406.4X25.4 (20X16X1)
376X402 (14-13/16X15-7/8)
508X508X25.4 477X402 (20X20X1)Right side (18-13/16X15-7/8)
view
Gas Pipe
Liquid pipe
(5/8)
(3/8)
3 Nominal Filter Size Duct Connection Model ø 9.52 (3/8) ø 6.35 MVZ-A12AA7 376X402 360 508X406.4X25.4 MVZ-A18AA7 (1/4) ø 12.7 (1/2) (20X16X1) (14-13/16X15-7/8) (14-3/16) MVZ-A24AA7 508X508X25.4 477X402 MVZ-A30AA7 ø 15.88(18-13/16X15-7/8) ø 9.52 (20X20X1) MVZ-A36AA7 461
792 (31-3/16)
(18-3/16)
MUZ-FH MUZ-FH MUZ-GL MUZ-GL MUZ-HM MUFZ-K
OUTDO MUZ-FH15N MUZ-FH18N MUZ-GL18N MUZ-GL24N MUZ-HM24 MUFZ-KJ15 13
2
OUTDOOR Air in
6
Air in
17-25/32
13
34-5/8
2
16-7
17-25/32
34-5/8
6-7/8
162
M-Series
INDOOR UNIT
MUZ-FH06NA MUZ-FH09NA MUZ-FH12NA MUZ-GL09NA MUZ-GL12NA MUZ-GL15NA MUZ-HM09NA MUZ-HM12NA MUZ-HM15NA MUZ-HM18NA
MUZ-FH06NAH MUZ-FH09NAH MUZ-FH12NAH MUY-GL09NA MUY-GL12NA MUY-GL15NA MUFZ-KJ09NAHZ MUFZ-KJ12NAHZ
Unit : inch
MUZ-JP09WA MUZ-JP12WA MUZ-WR09NA MUZ-WR12NA MUZ-WR18NA
REQUIRED SPACE *1 4 in. (100 mm) or more when
OUTDOOR UNIT
front and sides of the unit are clear
clear *1
MFZ-KJ09NA MFZ-KJ12NA MFZ-KJ15NA MFZ-KJ18NA
) mm 00 e . (1 or 4 in or m
4 in
. (1 or 00 m mo re m)
(MUZ-FH06/09/12NA) (MUZ-FH06/09/12NAH)
) mm 00 *2 . (2 8 in r more o
14
in. (3 or m 50 m ore m)
*2 When any 2 sides of left, right
and rear of the unit are clear
2 x hole 3/8 x 13/16
Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø 1/4 Gas refrigerant pipe joint Refrigerant pipe (flared) Ø 3/8
MUZ-FH15NA MUZ-FH18NA2 MUZ-GL18NA MUZ-GL24NA MUZ-HM24NA MUFZ-KJ15NAHZ
MUZ-D30NA MUY-D30NA MUZ-D36NA MUY-D36NA
MUZ-FH15NAH MUZ-FH18NAH2 MUZ-WR24NA MUY-GL18NA MUY-GL24NA MUFZ-KJ18NAHZ
OUTDOOR UNIT
REQUIRED SPACE
OUTDOOR UNIT
4 in
. or
Clear *1
REQUIRED SPACE *1 20 in. (500 mm) or more when front and sides of the unit are clear
Air in
1-5/8
m)
m 00 . (1 4 in more or
4 in or m . (10 ore 0 mm
mo
re
Open as a rule 20 inch or more if the back, both sides and top are open
in.
or m
ore
2
14-3/16
)
13
4 inch or more / 8 inch or more if there are obstacles to both sides
14
16-7/16
Drain hole 1-9/16
Open as a rule 20 inch or more if the front and both sides are open
Air in
Air out 6-7/8
)
mm 00 in. (5 20 ore *2 or m
2 x hole 13/32 x 13/16
19-11/16
33-1/16 4-5/16
14 or min. (35 ore 0 mm
)
*2 When any 2 sides of left, right and rear of the unit are clear
3-3/16
Service panel
35
17-25/32
34-5/8
Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø 1/4
6-1/2
3-29/32
44
7-11/16
Gas refrigerant pipe joint Refrigerant pipe (flared) Ø 1/2
163
M-Series Unit : inch/cm
SLZ-KF09NA SLZ-KF12NA SLZ-KF15NA SLZ-KF18NA
2-7/8( 73.4) Cut out hole
2-5/32(55)
V/M
Drain hole
V/M
Auto vane 14-27/32(377) Air intake hole
25-19/32(650)
0 12
3 / 9
1
Refrigerent pipe (gas)
1/4 inch ( 6.35mm) flared connection
3/8 inch ( 9.52mm) flared connection
SLZ-KA12NA
1/4 inch ( 6.35mm) flared connection
3/8 inch ( 9.52mm) flared connection
SLZ-KA15NA
1/4 inch ( 6.35mm) flared connection
1/2 inch ( 12.7mm) flared connection
Models Grille
V/M
3 22-11/16~24-13/32(576~620) ~ 5 1 ( 2 3 / 5 1 Ceiling - 1 hole ~ 2
Refrigerent pipe (liquid)
SLZ-KA09NA
Brand label
V/M
7-27/32(199) 13-27/32(352) 13-3/16(335) ) 7
25-19/32(650) 11-27/32(301) Air outlet hole
11-27/32(301) Air outlet hole
22-7/16(570)
13-3/16(335) 1-7/32(31)
2-1/4(57)
Ceiling surface 3-7/16(87)
Ceiling hole
16-17/32(420) Suspension bolt pitch
22-7/16(570)
2-7/32(56)
19/32~1-15/32(15~37)
Suspension bolt pitch
120
22-11/16~24-13/32(576~620)
1(25)
3-15/16( 100) 3- 1/8( 2.8) Burring hole
20-7/8(530)
1-3/8(35)
Detail drawing of fresh air intake
Fresh air intake
4-21/32(118)
19/32~1-15/32(15~37)
INDOOR UNIT
) 7
3
~
5
1 ( 2
3 / 5
1 - 1
~
2
3 / 9
Air intake grille
1
Vane motor
7-5/32(182)
1-1/16
Ceiling surface
2-5/32(55)
1-7/8(48)
8-3/16(208)
7-19/32(193)
+3/16 (27 +5) 0 0 25/32(20)
Grille
Terminal block
1-3/8(35)
Wiring entry
9-1/4(235)
9-1/16(230)
7-15/16(202)
3-21/32(93)
4-3/4(121)
Refrigerant 21/32(17) pipe (gas)
Drain pipe VP-25 connection (O.D. 1-1/4( 32)) Suspension bolt M10 or W3/8
Refrigerant pipe (liquid)
1-1/2~2-9/32(38~58) Suspension bolt lower edge
2-19/32(66)
14-27/32(377) Air intake hole
SEZ-KD09NA4 SEZ-KD12NA4 SEZ-KD15NA4 SEZ-KD18NA4 INDOOR UNIT Drain pipe(O.D.ø32(1-1/4)) (Emergency draining)
Suspension bolt hole 4-14X30(9/16X1-3/16) Slot
2XE-ø2.9(1/8)
23(29/32)
25(1) 100 (3-15/16)
150(Duct) (5-29/32)
700(27-9/16) 677(26-21/32)
23(29/32) 10(13/32)
Control box
116 (4-19/32)
Refrigerant piping flare connection (gas)
2
70 (2-25/32) 270(10-21/32)
Refrigerant piping flare connection (liquid)
88(3-15/32) H
100(3-15/16)XJ=K 100(3-15/16)
88(3-15/32) 20(13/16)
90 (3-9/16)
10(13/32) 625(Suspension bolt pitch) (24-5/8)
23(29/32)
49 (1-15/16)
102(4-1/32) 170(6-23/32) 200(7-7/8)
57(2-1/4)
20(13/16) 30(1-3/16)
25(1)
1
37(1-15/32) 100(3-15/16) 157.5 (6-7/32) 37(1-15/32)
Air filter
12(1/2)
A
Air inlet
N B (Suspension bolt pitch) C M
Air outlet
Drain pipe(O.D.ø32(1-1/4))
2X2-ø2.9(1/8)
20(13/16) 12(1/2)
L-ø2.9(1/8)
57(2-1/4)
D (Duct) 100(3-15/16)X(E-1)=F 100(3-15/16)
15(19/32)
159(6-9/32)
345(13-19/32)
Knockout hole ø27(1-3/32) (Indoor/outdoor connecting line)
Knockout hole ø27(1-3/32) (Remote controller transmission line)
Terminal block (Indoor/outdoor connecting line)
Terminal block (Remote controller transmission line) Drain pipe(O.D.ø32(1-1/4)) (Spontaneous draining) B Model A 700 752 SEZ-KD09NA4 (27-9/16) (29-5/8) SEZ-KD12NA4 900 952 (35-7/16) (37-1/2) SEZ-KD15NA4
) 7 77 9/32 -1 Access (30
Note2
50 (1 G -31/3
2)
(1-3
1/3 50 2~ ~1 5-2 50 9/3 2
)
(17 450 -23 /32 )
0 0 45 2) /3 n 30 6) /1 -23 tha -13 (17 ore (11 M
Required space for service and maintenance
164
175±5(6-29/32±7/32) (Actual length)
door
More than 10 (13/32) More than 20 (13/16)
2)
1/3
(1-3 50
Less than 550 (21-21/32)
Less than 300 (11-13/16)
Drain hose (I.D.ø32(1-1/4)) <accessory>
Ceiling surface Access door
Make the access door at the appointed position properly for service maintenance.
C
D
E
(26)
7
798
660
998
860
(31-7/16)
(39-5/16) (33-7/8)
1100 1152 1198 1060 SEZ-KD18NA4 (43-5/16) (45-3/8) (47-3/16) (41-3/4)
9 11
F
H
J
(26)
5
860
7
(27-9/16)
1000 1200 1060
9
(35-7/16)
600
G
800
660
800 1000
(23-5/8) (31-1/2)
(31-1/2) (39-3/8) (33-7/8) (39-3/8) (47-1/4) (41-3/4)
Note1.Use M10 screw for the suspension bolt (field supply). 2.Keep the service space for the maintenance at the bottom. 3.This chart indicates for SEZ-KD15NA4 model,which has 3 fans. SEZ-KD09,12NA4 models have 2 fans. SEZ-KD18NA4 models have 4 fans. 4.In case an inlet duct is used,remove the air filter (supply with the unit), then install the filter (field supply) at suction side.
K
500
L
(19-11/16)
16
M
700
1039 990 20 (40-29/32) (39)
900
1239 1190 24 (48-25/32) (46-7/8)
839
N
790
(33-1/16) (31-1/8)
1
Gas pipe
mm(in.)
2
Liquid pipe
ø9.52(3/8) ø6.35(1/4) ø12.7(1/2)
M-Series OUTLINES AND DIMENSIONS
4
SUZ-KA09NA2 SUZ-KA12NA2 SUZ-KA15NA2
OUTLINES AND DIMENSIONS
Unit:SUZ-KA18NA(H)2.TH inch(mm) SUZ-KA18NA2
SUZ-KA09NA(H)2.MX SUZ-KA12NA(H)2.MX SUZ-KA15NA(H)2.MX
Unit : inch
SUZ-KA24NA2 SUZ-KA30NA2 SUZ-KA36NA2 SUZ-KA24NA(H)2.TH SUZ-KA30NA(H)2.TH SUZ-KA36NA(H)2.TH
SUZ-KA09NAHZ SUZ-KA12NAHZ SUZ-KA15NAHZ SUZ-KA18NAHZ
OUTDOOR UNIT REQUIRED SPACE
REQUIRED SPACE *1 20 in. (500 mm) or more when front and sides of the unit are clear
) mm 00 e . (1 or 4 in or m
4 in
.( or 100 m mo re m)
Air in
13
2
(KA09/12/15NA) (KA09/12/15NAH)
16-7/16
) mm 00 . (2 e *2 8 in r mor o
14
Drain hole 1-9/16
m)
1-5/8
Air in
in. ( or m350 m ore m)
)
mm 00 in. (5 2 20 ore * or m
Air out 2-holes 13/32 13/16 6-7/8
*2 When any 2 sides of left, right
m 00 . (1 4 in more or
4 in or m . (10 ore 0 mm )
14-3/16
front and sides of the unit are clear
clear *1
*1 4 in. (100 mm) or more when
19-11/16
33-1/16 4-5/16
holes
3-3/16
Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø 1/4 (KA18) Refrigerant pipe (flared) Ø 3/8 (KA24/30/36) 34-5/8 17-25/32
35
3-29/32
6-1/2
44
7-11/16
4
)
Service panel
Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø 1/4 Gas refrigerant pipe joint Refrigerant pipe (flared) Ø 3/8 (KA09/12) Ø 1/2 (KA15)
14 or min. (3 ore 50 m m
*2 When any 2 sides of left, right and rear of the unit are clear
and rear of the unit are clear
OCH699
Unit: inch
OUTDOOR UNIT Clear *1
4
OCH688
Gas refrigerant pipe joint Refrigerant pipe (flared) Ø 1/2 (KA18) Refrigerant pipe (flared) Ø 5/8 (KA24/30/36)
4
165
External Dimensions: P-Series
INDOOR UNIT
(89) 3-1/2
VANE MOTOR
PLA-A.EA7*:12/18/24/30/36/42 F
15-3/16(387)
AIR INTAKE GRILLE
FRESH AIR INTAKE HOLE
Right side
(CEILING HOLE)
26
A
27-1/16(688)
2-1/8 (55)
9-13/16(249)
6-1/16(155)
35-3/8(898)
3/16(5)
Knock out hole for right piping
BRANCH DUCT HOLE
(60) 2-3/8
BRANCH DUCT HOLE
33-1/16(840)
(20-45) 13/16 TO 1-3/4
(222) 8-3/4
1/4(6)
(145) 5-11/16
(193) 7-5/8
5-11/16(145)
C
(20) 13/16
SUSPENSION BOLT M10 OR W3/8
D
3-1/8(79.5)
{ 5-7/8({ 150) CUTOUT HOLE (CONNECTING TO BRANCH DUCT) { 6-7/8({ 175) BURRING HOLE PITCH SELF-TAP 4 SCREWS:4 PLACES (CONNECTING TO BRANCH DUCT)
33-7/8 TO 35-13/16(860-910)
+1-9/16 0
(660+400)
INDOOR UNIT/ OUTDOOR UNIT CONNECTING TERMINAL BLOCK
(133) 5-1/4
BRANCH DUCT HOLE
REMOTE CONTROLLER TERMINAL BLOCK
(SUSPENSION BOLT PITCH)
33-1/16(840)
17-11/16(450)
(145) 5-11/16
(20) 13/16
GRILLE
70°
Front side
11-5/8(295)
(20-45) 13/16 TO 1-3/4
31-5/16 (795) (SUSPENSION BOLT PITCH)
(145) 5-11/16
(20-45) 13/16 TO 1-3/4
(37) 1-7/16 REMOTE CONTROLLER WIRE ENTRY
23-9/16(599)
AUTO VANE
BRANCH DUCT HOLE
(CEILING HOLE) 33-7/8 TO 35-13/16(860-910)
(20-45) 13/16 TO 1-3/4
Air outlet Mount board
SOME GRILLES DO NOT HAVE THIS PART. *CAN INSTALL TO THE CORNER EXCEPT DRAIN PIPE CORNER (NEED TO FUNCTION SETTING BY REMOTE CONTROLLER)
37-3/8(950) COMPANY NAME
REMOTE CONTROLLER WIRE ENTRY
1/16(2)
Top side
I-SEE SENSOR CORNER PANEL
(AIR OUTLET HOLE)
20-7/8(530)
DRAIN HOLE
CEILING
7-1/2(192)
7-3/4(197)
177-3/16(4500) OR LESS
20(508)
137-13/16(3500) OR LESS
(AIR INTAKE HOLE)
E
12(305) OR MORE
(89) 3-1/2
3-1/8 (79.5)
20-7/8(530)
D
3(76) 3(76.5) 10-7/16(265) OR MORE
37-3/8(950)
C
B 10-3/16 (258)
REFRIGERANT PIPEΦ9.52 REFRIGERANT PIPEΦ15.88 11-1/16 11-3/4 FLARED CONNECTION 3/8F FLARED CONNECTION 5/8F (281) (298)
(AIR OUTLET HOLE)
A REFRIGERANT PIPEΦ6.35 REFRIGERANT PIPEΦ12.7 9-1/2 FLARED CONNECTION 1/4F FLARED CONNECTION 1/2F (241)
INDOOR
CORNER POCKET
20(508) (AIR INTAKE HOLE)
MODELS
PCA-A36KA
INDOOR UNIT
OPTIONAL PART:SIGNAL RECEIVER
1-7/16(37)
Unit : inch/cm
PKA-A12HA7 PKA-A18HA7
PLA-A12EA7 PLA-A18EA7 PLA-A24EA7 PLA-A30EA7 PLA-A36EA7 PLA-A42EA7
DRAIN PIPE VP-25 CONNECTION (CONNECTED THE ATTACED DRAIN SOCKET)
MAIN UNIT
24-3/4(628)
1
SUSPENSION BOLT LOWER EDGE
11/16
B (40) 1-9/16
+3/16 0
(105)
(17+50)
CEILING GRILLE INDOOR UNIT/OUTDOOR UNIT CONNECTING WIRE, POWER SUPPLY WIRE ENTRY
4-1/8
(58)
THE BOTTOM OF I-SEE SENSOR
2-5/16
(50-70) 1-15/16 TO 2-3/4
(170) 6-11/16 (140) 5-1/2
(190) 7-1/2
A
2
PKA-A24KA7 PKA-A30KA7 PKA-A36KA7
INDOOR UNIT
INDOOR
Top side
17(431.7) 50-3/8(1280)
2(51)
1/16(2)
3/8(10)
46-3/16(1173)
3/16(5)
liquid Φ3/8(Φ9.52) gas Φ5/8(Φ15.88)
When drain socket is installed
Drainage
Emergency operation switch <Heating>
Secon (Emer ø19.05
26-3/4(680)
G Air intake
47-3/16(1198)
18-3/4(476)
10(254)
Knockout hole for right piping Operation lamp DEFROST/STAND BY lamp Receiver
7-7/8(200) 9-3/16(233) 9-11/16(246)
Emergency operation switch <Cooling>
3/16(5)
11-5/8(295)
7-1/16(180)
H
14-3/8(365)
9-1/2(241)
In case of wireless remote controller and i-see Sensor (Optional Parts)
2-ø4.6 Burring for electric hea Refrigerant piping brazing connection(ga Refrigerant piping brazing connection(liqu Secondary drain p (Emergency drain ø19.05(3/4) 3/4"F Primary drain (Gravity drain) ø19.05(3/4) 3/ (Horizontal lef
In case of wireless remote controller and i-see Sensor (Optional Parts)
C
33-21/32(855) 46-1/16(1170)
9/16 14
9-1/16(230) 3-3/8(85) 2-1/4(57)
Mount board
3-7/16(88)
3-5/16(84) 7-3/16(182)
7-11/16(195)
Air outlet
Right side
Front side
2-29/32(74)
1 2
70(2-13/16) 55(2-3/16)
1/16(2)
9-5/16(236)
16-11/16(423.7)
7/16(11)
5-17/32(140.3) 2-9/16(65.2)
PVA-A12AA PVA-A30AA
PCA-A24KA7 PCA-A30KA7
INDOOR UNIT
i-see Sensor
DEFROST/STAND BY lamp Receiver Operation lamp
NOTES. 1.Use M10 or W3/8 screw for anchor bolt. 2.Please be sure when installing the drain pump (option parts), refrigerant pipe will be only upward.
Model
3
Nom
508
PVA-A30AA4 PVA-A36AA4 PVA-A42AA4 Model PVA-A30AA4 PVA-A36AA4
PVA-A42AA4
166
(
508
(
A 534 (21)
635 (25)
P-Series Unit : inch/cm
PCA-A36KA7 PCA-A42KA7
PEAD-A09AA7 PEAD-A12AA7 PEAD-A15AA7 PEAD-A18AA7 PEAD-A24AA7 PEAD-A30AA7 PEAD-A36AA7 PEAD-A42AA7
INDOOR UNIT
INDOOR UNIT 2(51)
Opposite piping side view
3/8(10) 3/16(5)
378(14-15/16)
153(6-1/16)
Fresh air intake ø100(3-15/16) knock out hole Note 4 3-ø2.9(1/8) mount hole
Drain pipe(O.D ø32(1-1/4))
Outlet air side view
210(8-5/16)
0° 12
J±3(J±1/8)
G
A
C
21(7/8)
23(15/16)
(Suspension bolt pitch)
57(2-1/4)
643(25-3/8)
Unit:mm(in.) Model PEAD-A12,18AA7 PEAD-A24,30AA7 PEAD-A36,42AA7
A 900
(35-7/16)
1100
(43-5/16)
1400
(55-1/8)
Air filter
10(7/16)
20(13/16)
58(2-5/16)
40(1-5/8)
Air intake
Air inlet
Air outlet
B(Suspension bolt pitch)
D(Duct)
DEFROST/STAND BY lamp Receiver Operation lamp
H±3(H±1/8)
Inlet air side view 18(3/4)
Top view
Emergency operation switch <Heating>
Emergency operation switch <Cooling>
ø125 ) 16 (4-15/
Top 2XE-ø2.9(1/8)
100(3-15/16)X(E-1)=F
26-3/4(680)
18-3/4(476)
10(254) 59-3/4(1518)
15(5/8)
Drainage
In case of wireless remote controller and i-see Sensor (Optional Parts)
Bottom
100(3-15/16)
9-11/16(246)
3-3/8 85
When drain socket is installed
30(1-3/16)
9-3/16(233)
liquid Φ3/8(Φ9.52) gas Φ5/8(Φ15.88)
40(1-5/8)
9/16 14
7-7/8(200)
120°
200(7-7/8)
9-5/16(236)
9-1/16(230) 3-5/16(84)
3-7/16(88)
7-1/16(180)
In case of wireless remote controller and i-see Sensor (Optional Parts)
2-1/4 57
7-3/16 182
7-11/16(195)
Air outlet
(Emergency drain)
(5-3/8)
1/16(2)
63(1600) 58-3/4(1493)
135
1/16(2)
B 954
(37-9/16)
1154
(45-7/16)
1454
(57-1/4)
1000
(39-3/8)
1200
(47-1/4)
1500
(59-1/16)
D 860
(33-7/8)
1060
(41-3/4)
1360
(53-9/16)
E 9
CF 800
(31-1/2)
1000
11
(39-3/8)
14
(51-3/16)
1300
G 858
(33-13/16)
1058
(41-11/16)
1358
(53-1/2)
H 72
(2-7/8)
78
(3-1/8)
Unit:mm(in.) Model PEAD-A12,18AA7 PEAD-A24,30AA7 PEAD-A36,42AA7
J 62 (2-1/2) 66 (2-5/8)
1 Gas pipe 2 Liquid pipe ø12.7 ø6.35 (1/2) (1/4) ø15.88 (5/8)
ø9.52 (3/8)
PVA-A12AA7 PVA-A18AA7 PVA-A24AA7 PVA-A30AA7 PVA-A36AA7 PVA-A42AA7
8(3/8)
92(3-5/8)
30(1-3/16)
G H
55(2-3/16)
D
A 3
Air filter
470(18-9/16)
Nominal Filter size Duct Connection 508X508X25.4
PVA-A30AA4 PVA-A36AA4 PVA-A42AA4 Model PVA-A30AA4 PVA-A36AA4
PVA-A42AA4
Right side view
36.8(1-1/2)
J
3
Bottom
Air inlet
Bottom view
Model
ø26 Knockout Hole (Remote controller transmission)
55(2-3/16)
Secondary drain pipe (Emergency draining) ø19.05(3/4) 3/4"FPT (Horizontal Right) Primary drain pipe (Gravity drain) ø19.05(3/4) 3/4"FPT
(Duct)
E
43(1-3/4) Secondary drain pipe (Emergency draining) ø19.05(3/4) 3/4"FPT
43(1-3/4)
548(21-5/8) 402(15-7/8)
Top
Terminal block (Remote controller transmission) Terminal block (Indoor / Outdoor unit connection) Control box Primary drain pipe (Gravity drain) ø19.05(3/4) 3/4"FPT
117.4 (4-5/8)
Front view
F
70(2-13/16) 55(2-3/16)
8(3/8)
28.8(1-3/16) 76(3)
8(3/8)
B(Duct) C
Air outlet
525.5(20-3/4)
2-ø4.6 Burring Holes for electric heat installation Refrigerant piping brazing connection(gas) Refrigerant piping brazing connection(liquid) Secondary drain pipe (Emergency draining) ø19.05(3/4) 3/4"FPT Primary drain pipe (Gravity drain) ø19.05(3/4) 3/4"FPT (Horizontal left)
50.8(2)
1 2
13.2(9/16) 24(15/16)
INDOOR UNIT
477X402
(20X20X1)
(18-13/16X15-7/8)
508X609.6X25.4
579X402
(20X24X1)
A 534 (21)
635 (25)
(22-13/16X15-7/8)
B
C
D
E
F
G
H
J
477
382.6
266.5
1378
737
953.5
792
461
(18-13/16) (15-1/8) (10-1/2) (54-1/4) (29-1/16) (37-9/16) (31-3/16) (18-3/16)
579
484.6
317.5
1511
798.5
1053
853.5
563
1
Gas pipe
Ø15.88 (5/8)
2
Liquid pipe
Ø9.52 (3/8)
(22-13/16) (19-1/8) (12-1/2) (59-1/2) (31-7/16) (41-1/2) (33-5/8) (22-3/16)
167
P-Series
PUZ-A12NKA7 PUZ-A18NKA7 PUY-A12NKA7 PUY-A18NKA7
PUZ-A24NHA7 PUZ-A30NHA7 PUY-A24NHA7 PUY-A30NHA7
PUZ-A12NKA7-BS PUZ-A18NKA7-BS PUY-A12NKA7-BS PUY-A18NKA7-BS
OUTDOOR UNIT
Unit : inch/cm
PUZ-A24NHA7-BS PUZ-HA24NHA PUZ-A30NHA7-BS PUY-A24NHA7-BS PUY-A30NHA7-BS
OUTDOOR UNIT Rear Air Intake 2-U Shaped notched holes (Foundfation Bolt M10<W3/8>) 175 <6-7/8>
40 <1-19/32>
330 <13>
23.2<15/16> Terminal connection Left ... Power supply wiring Right ... Indoor/Outdoor wiring
Connection for liquid pipe FLARE ø6.35 (1/4F)
Handle for moving
310 <12-7/32> 62 <2-15/32>
Connection for gas pipe FLARE ø12.7 (1/2F)
61<2-13/32> 40<19/32> 0 53<2-3/32>
41 <1-5/8>
Terminal Connections Left ... Power supply wiring Reight ... Indoor/Outdoor wiring
950 <37-13/32> 322<12-11/16> Earth terminal
Service port
185.5 <7-5/16>
Handle for moving 943 <37-1/8> 473 <18-5/8> 23 <29/32>
492<19-3/8>
164.5<6-1/2>
154.5 <6-3/32>
99.5<3-15/16>
2- ø 22.2<7/8> 1/2 conduit hole
43 °
8.5 <11/32>
57<2-1/4>
Service panel
Service panel
35 °
630 <24-13/16>
Side Air Intake
Earth terminal 320<12-5/8>
70 <2-3/4>
Service panel for charge plug
Handle for moving
809 <31-7/8>
Air Discharge
2-12×36 oval holes (Foundation Bolt M10<W3/8>)
2-10×21 oval hole (Foundation Bolt M10 <W 3/8>) 22 <7/8>
22.3 <29/32>
25 <31/32>
330<13> 360<14-3/16>
300<11-13/16>
Air discharge
32.5<1-9/32>
Air intake
19<3/4>
Side Air Intake
370<14-9/16> 417 <1-1/32>
2-U Shaped notched holes (Foundation Bolt M10<W 3/8>)
500<19-11/16>
28<1-3/32>
Installation bolt pitch
1 2
669<26-11/32>
Air intake
175<6-7/8>
Installation Feet
*1 447<17-5/8>
drain hole ø 42
*1 431<16-31/32>
48<1-29/32>
404.5<15-15/16>
600<23-5/8>
Front piping cover Rear piping cover
PUZ-A36NKA7 PUZ-A42NKA7 PUY-A36NKA7 PUY-A42NKA7
PUZ-HA30NHA5 PUZ-HA36NHA5
PUZ-A36NKA7-BS PUZ-A42NKA7-BS PUY-A36NKA7-BS PUY-A42NKA7-BS
OUTDOOR UNIT
OUTDOOR UNIT Rear Air Intake
2-U Shaped notched holes (Foundation Bolt M10<W3/8>)
225 <8-27/32>
600 <23-5/8>
Installation Feet
56 <2-7/32>
Side Air Intake
362 <14-1/4>
2-12×36 Oval holes (Foundation Bolt M10<W3/8>)
1050 <41-11/32>
42 <1-21/32>
(
Earth terminal
53 <2-3/32> 28 <1-3/32>
25 <31/32>
Air Discharge
60 <2-3/8>
40<1-9/16>
0 70 <2-3/4>
370 <14-9/16>
330 <13>
Side Air Intake
417 <16-13/32>
19 <3/4>
225 <8-27/32>
Terminal connection Left ... Power supply wiring Right ... Indoor/Outdoor wiring
)
1338 <52-11/16> 632 <24-7/8>
Service panel
1063 <41-7/8>
Handle for moving
1
*1 442 <17-2/5>
2
Air intake
*1 450 <17-23/32>
369 <14-17/32> 26 <1-1/32>
Handle for moving
Front piping cover Rear piping cover
168
P-Series Unit : inch/cm
Unit : inch
PUZ-HA42NKA OUTDOOR UNIT
* *
ng
cover ng cover
169
External Dimensions: MXZ Model
MXZ-2C20NA2
OUTDOOR UNIT
OUTDOOR UNIT
6-23/32”
23/32”
Air Inlet
15/32” 11/16”
Air Inlet Air Outlet
3-ø(1-5/16”) Drain hole
15-19/32”
11/16”
12-3/8”
(Bolt Pitch)
19-11/16”
14-3/16”
8-5/32”
21/32”
1-11/32”
6-21/32” 2-9/16”
Unit : inch/cm
MXZ-3C24NA2 MXZ-3C30NA2 MXZ-4C36NA2
4-(13/32”×13/16”) Oval Hole (Foundation Bolt M8)
33-1/16”
1-3/16” 1-1/32”
9-7/16”
7-7/8”
13”
1/2”
14-3/16”
27-15/16”
2-19/32” Connecting wire hole
LIQ GAS LIQ GAS
Unit B Unit A
LIQ 1/4”(ø6.35)FLARE GAS 3/8”(ø9.52)FLARE
11-25/32”
OUTDOOR UNIT Rear Air Intake
600 <23-5/8>
225 <8-27/32>
2-U Shaped notched holes (Foundation Bolt M10<W3/8>) 19 <3/4>
225 <8-27/32>
330 <13>
70 <2-3/4>
25 <1>
Side Air Intake
370 <14-9/16>
Installation Feet
Air Discharge 1050 <41-11/32> 362 <14-1/4> Handle for moving
Ground for the power supply ("GR"marking position)
42 <1-21/32> 60.5 <2-3/8>
417 <16-13/32>
OUTDOOR UNIT
MXZ-8C48NA2 MXZ-8C60NA2 MXZ-4C36NAHZ2 MXZ-5C42NAHZ2 MXZ-8C48NAHZ2
56 <2-7/32> 39.5 <1-9/16> 0 53 <2-3/32>
28 <1-3/32>
MXZ-5C42NA2 MXZ-2C20NAHZ2 MXZ-3C24NAHZ2 MXZ-3C30NAHZ2
2-12×36 Oval holes (Foundation Bolt M10<W3/8>) Terminal connection From left to right For the power supply
For the branch box power supply
For the transmission line
For concentration control
Ground for the transmission line Ground for concentration control
Ground for the branch box power supply
632 <24-7/8>
1067 <42>
Air intake
485 <19-3/32>
1 2
426 <16-25/32>
26 <1-1/32>
369 <14-17/32>
1338 <52-11/16>
Service panel
Handle for moving
Front piping cover Rear piping cover
170
MXZ Model
PAC-MKA32BC
PAC-MKA52BC
Branch Box
Branch Box
Unit : inch/cm
402 (15-13/16)
SUSPENSION BOLT PITCH
402 (15-13/16)
SUSPENSION BOLT PITCH 24 (1)
24 (1)
SUSPENSION BOLT PITCH 320 (12-19/32)
SUSPENSION BOLT PITCH 320 (12-19/32)
12 (1/2)
12 (1/2)
E
25 (1)
TERMINAL BLOCK TO OUTDOOR UNIT
E
D
D
C
C
B
B
A
112 (4-3/8)
65 (2-9/16)
170 (6-11/16)
112 (4-3/8)
47 (1-27/32)
TERMINAL BLOCK TO INDOOR UNIT
5-ELECTRIC WIRE INLET
25 (1) 70 (2-3/4)
25 (1) 70 (2-3/4)
25 (1) 70 (2-3/4)
A
25 (1) 70 (2-3/4)
CONTROL COVER TO OUTDOOR UNIT SERVICE PANEL (for LEV, THERMISTOR)
CONDUIT PLATE
TB3E
65 (2-9/16)
TERMINAL BLOCK TO M-NET UNIT
40 (1-17/32)
70 (2-3/4)
TB2B
REFRIGERANT PIPE FLARED CONNECTION A B C LIQUID PIPE 1/4F 1/4F 1/4F GAS PIPE 3/8F 3/8F 3/8F
CONDUIT PLATE
280 (11-1/32) 87 (3-7/16)
TB3D
SUSPENSION BOLT : W3/8(M10)
CONTROL COVER
83 (3-9/32)
TB3C
TO OUTDOOR UNIT SERVICE PANEL (for LEV, THERMISTOR)
96 (3-25/32)
TB5
25 (1) 70 (2-3/4)
72 (2-27/32)
TB3B
A
TO INDOOR UNIT
TB3A
70 (2-3/4)
A
TB2B
25 (1)
25 (1)
B
90 (3-17/32)
450 (17-23/32) 67 (2-9/16)
TERMINAL BLOCK TO INDOOR UNIT
5-ELECTRIC WIRE INLET
TB3B
B
TERMINAL BLOCK TO M-NET UNIT
40 (1-17/32)
70 (2-3/4)
TB3C
CAP
C
280 (11-1/32) 87 (3-7/16)
TB5
C
96 (3-25/32) 83 (3-9/32)
TO INDOOR UNIT
TB3A
170 (6-11/16)
72 (2-27/32)
CAP
47 (1-27/32)
90 (3-17/32)
450 (17-23/32) 209 (8-7/32)
TERMINAL BLOCK TO OUTDOOR UNIT
SUSPENSION BOLT : W3/8(M10)
Unit: inch TO OUTDOOR UNIT 3/8F 5/8F
REFRIGERANT PIPE FLARED CONNECTION Unit: inch A B C D E TO OUTDOOR UNIT LIQUID PIPE 1/4F 1/4F 1/4F 1/4F 1/4F 3/8F GAS PIPE 3/8F 3/8F 3/8F 3/8F 1/2F 5/8F
171
Eco Changes is the Mitsubishi Electric Group’s environmental statement, and expresses the Group’s stance on environmental management. Through a wide range of businesses, we are helping contribute to the realization of a sustainable society.
NOTICE ● Do not install indoor units in areas (e.g. mobile phone base stations) where the emission of VOCs such as phthalate compounds and formaldehyde is known to be high as this may result in a chemical reaction ● Our air-conditioning equipment and heat pumps contain a fluorinated greenhouse gas, R410A ● When installing or relocating or servicing our air-conditioning equipment, use only the specified refrigerant (R410A) to charge the refrigerant lines ● Do not mix it with any other refrigerant and do not allow air to remain in the lines ● If air is mixed with the refrigerant, then it can be the cause of abnormal high pressure in the refrigerant lines, and may result in an explosion and other hazards ● The use of any refrigerant other than that specified for the system will cause mechanical failure, system malfunction or unit breakdown. In the worst case, this could lead to a serious impediment to securing product safety
© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Mitsubishi Electric, Lossnay, and the three-diamond logo are trademarks of Mitsubishi Electric Corporation. CITY MULTI, kumo cloud, kumo station and H2i are registered trademarks of Mitsubishi Electric US, Inc. Trane and American Standard are registered trademarks of Trane Technologies plc. All other product names mentioned herein are trademarks or registered trademarks of their respective owners. ENERGY STAR and the ENERGY STAR mark are registered trademarks owned by the United States Environmental Protection Agency. Use of the AHRI Certified® mark indicates a manufacturer’s participation in the certification program. For verification of certification for individual products, go to www.ahridirectory.org. Specifications shown in this brochure are subject to change without notice. See complete warranty for terms, conditions and limitations. A copy is available from Mitsubishi Electric Trane HVAC US LLC. Printed in the USA SKU: ME_RS_0396_02-20 | Printed in the USA