PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION

LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION

S

5.30

MC25

4.50

ARC 13.68 S

S

6.3 1

S

S

29.98

4.50 S

MC25

5.00

S

5.00

25.49

7101

17.00

S

5.50

5.00

4.00

S

6.00

S

5.50

518.1 m²

0 6.0

PROJECT

PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.

0

5m

1 : 250 DATUM

DRAWN

CHECKED

AHD

AA

JT

Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com

TITLE

DISCLOSURE PLAN LOT NO. 7101

PROJECT CODE

DRAWING No.

ISSUE

AA006310

LOT-7101

01 C


PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION

5.30

PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION

LEGEND S

SA

MC25 4.50

SA

ARC 15.00 S

S

S

S

S

5.00

S

4.50 S

5.00

S

5.50

30.03

29.98

6.00

7102

S

6.00

S

5.50

431.1 m²

6.50

13.70

5.50

5.00

S

6.50

0

6.0

PROJECT

PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.

0

5m

1 : 250 DATUM

DRAWN

CHECKED

AHD

AA

JT

Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com

TITLE

DISCLOSURE PLAN LOT NO. 7102

PROJECT CODE

DRAWING No.

ISSUE

AA006310

LOT-7102

01 C


PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION

LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION

S

5.30

SA

MC25 SA

ARC 11.00

S

S

S

S

S 5.50

5.50

6.00

30.03

30.04

6.00

5.50

7103

6.00

320.0 m²

6.50

6.50 6.77

3.56

5.50

6.50

6.0 0 PROJECT

PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.

0

5m

1 : 250 DATUM

DRAWN

CHECKED

AHD

AA

JT

Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com

TITLE

DISCLOSURE PLAN LOT NO. 7103

PROJECT CODE

DRAWING No.

ISSUE

AA006310

LOT-7103

01 C


PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION

5.30

PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION

LEGEND S

SA

MC25 SA 5.00

S

S

ARC 13.00

S

S

5.50

5.50

5.50

6.00

6.00

30.04

6.00 30.01

7104 379.6 m²

6.50

6.00

6.50

6.50

9.03

3.27

6.50

0

6.0

6.50

PROJECT

PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.

0

5m

1 : 250 DATUM

DRAWN

CHECKED

AHD

AA

JT

Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com

TITLE

DISCLOSURE PLAN LOT NO. 7104

PROJECT CODE

DRAWING No.

ISSUE

AA006310

LOT-7104

01 C


PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION

LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION

S

5.30

5.00

MC25 5.00 5.00

ARC 13.00

S

S

5.50

5.50

5.50

6.00 6.00

6.00

30.02

30.01

6.00

7105

380.3 m²

6.50

6.50

6.50 6.50

8.46

3.89

6.50

(REFER TO C-

PROJECT

PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.

0

5m

1 : 250 DATUM

DRAWN

CHECKED

AHD

AA

JT

Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com

TITLE

DISCLOSURE PLAN LOT NO. 7105

PROJECT CODE

DRAWING No.

ISSUE

AA006310

LOT-7105

01 C


PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION

5.30

PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION

LEGEND S

5.00

MC25

5.00 S

5.50

5.00

S

ARC 11.00

5.00

5.50

5.50 5.50

6.00

6.00

6.00 6.00

29.98

30.02

7106 321.3 m²

6.50

6.50

6.50

6.50

10.41

(REFER TO C-FG-03 PACKAGE OF WOR PRECINCT F AND G STAGE 3 SHELL COVE

PROJECT

Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289

NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.

0

5m

1 : 250 DATUM

DRAWN

CHECKED

AHD

AA

JT

Tel: +61 (0)2 8907 9000 www.arcadis.com

TITLE

DISCLOSURE PLAN LOT NO. 7106

PROJECT CODE

DRAWING No.

ISSUE

AA006310

LOT-7106

01 C


PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION

LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION

S

5.30

5.00

MC25

4.50

5.00

S

5.50

S

5.50

ARC 11.00

5.50

S

5.00

5.00

5.50

6.00 6.00

6.00

30.03

29.98

6.00

7107

320.5 m²

6.50

6.50

6.50

6.50

6.50

10.35

6.50 PROJECT

PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.

0

5m

1 : 250 DATUM

DRAWN

CHECKED

AHD

AA

JT

Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com

TITLE

DISCLOSURE PLAN LOT NO. 7107

PROJECT CODE

DRAWING No.

ISSUE

AA006310

LOT-7107

01 C


PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION

LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION

S

5.30

MC25

4.50

ARC 13.00 S

S

S

S

S

5.00

4.50

S

5.00

5.00

5.50 5.50

30.03

6.00

30.03

5.50

7109 380.5 m² 6.00

6.00

6.50 6.50

6.50

5.80

6.55

6.50

6.50 PROJECT

PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.

0

5m

1 : 250 DATUM

DRAWN

CHECKED

AHD

AA

JT

Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com

TITLE

DISCLOSURE PLAN LOT NO. 7109

PROJECT CODE

DRAWING No.

ISSUE

AA006310

LOT-7109

01 C


PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION

LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION

S

5.30

MC25

ARC 11.00 4.50

S

S

S

S

S

5.00

4.50

S

4.50

5.00

S

5.00 5.50 5.50

S

30.03

30.03

5.50

7110

6.00

319.4 m² S

6.00

6.00

S

6.50

2.23

8.05 6.50

PROJECT

PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.

0

5m

1 : 250 DATUM

DRAWN

CHECKED

AHD

AA

JT

Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com

TITLE

DISCLOSURE PLAN LOT NO. 7110

PROJECT CODE

DRAWING No.

ISSUE

AA006310

LOT-7110

01 C


PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION

5.30

PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION

LEGEND S

MC25

4.50

4.00

4.50 ARC 15.00

S

S

S

S

S

S

4.50

5.00

5.00

S

5.00

17.01

5.00

5.50

5.50

30.03

S

5.50

5.5

0

7111 6.00 S

6.00

5.50

S

13.00

6.00

0

6.0

13.94

6.0

0

6.50

PROJECT

PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.

0

5m

1 : 250 DATUM

DRAWN

CHECKED

AHD

AA

JT

Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com

TITLE

DISCLOSURE PLAN LOT NO. 7111

PROJECT CODE

DRAWING No.

ISSUE

AA006310

LOT-7111

01 C


PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION

LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION

S

5.30

S

4.00

SA

0 4.0

MC25

4.00

4.00

ARC 25.17 S

S

S

S

SA

S

5

4.50

6.4

4.50

5.0

12.36

7112

0

S

496.2 m²

MC23

SA

17.01

S

5.00

5.5

0

29.67

S

S

5.50

0 6.0 PROJECT

PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.

0

5m

1 : 250 DATUM

DRAWN

CHECKED

AHD

AA

JT

Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com

TITLE

DISCLOSURE PLAN LOT NO. 7112

PROJECT CODE

DRAWING No.

ISSUE

AA006310

LOT-7112

01 C


PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION

S

0 4.0

SA

MC25

5.30

S

PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION

LEGEND

4.00

4.00 S

S

S

S

S

SA

4.50

4.50

SA

S

5.00

5.0

S

0

5.5

0

MC23

29.67

13.00

13.00

S

5.50

7113

S

385.7 m²

0 6.0 4.50

5.00

4.00

0 6.0

5.5 0

S

6.0 0

29.67

PROJECT

PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.

0

5m

1 : 250 DATUM

DRAWN

CHECKED

AHD

AA

JT

Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com

TITLE

DISCLOSURE PLAN LOT NO. 7113

PROJECT CODE

DRAWING No.

ISSUE

AA006310

LOT-7113

01 C


PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION ALTERNATIVE INTERSECTION LAYOUT OPTION

LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION

S

S

0 6.0

SEAFARING WAY

S

5.50

7114

13.00

5.00

0

0 6.0

5.5

S

13.00

29.67

S

385.7 m²

S

S

SA

29.67

S

S

S

S

S

SA

BRIGANTINE DR S PROJECT

PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.

0

5m

1 : 250 DATUM

DRAWN

CHECKED

AHD

AA

JT

Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com

TITLE

DISCLOSURE PLAN LOT NO. 7114

PROJECT CODE

DRAWING No.

ISSUE

AA006310

LOT-7114

02 C


PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION ALTERNATIVE INTERSECTION LAYOUT OPTION

LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION

S

S

5.00

S

0 6.0 0

0

S

5.5

6.0

SEAFARING WAY

SA

4.50 12.67

S

5.5

0

5.0 0

29.67

7115

S

S

S

S

6.2

6

S

17.01

492.6 m²

ARC 25.17

S

SA

S

4.50

BRIGANTINE DR SA

S PROJECT

PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.

0

5m

1 : 250 DATUM

DRAWN

AHD

AA

CHECKED

JT

Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com

TITLE

DISCLOSURE PLAN LOT NO. 7115

PROJECT CODE

AA006310

DRAWING No.

LOT-7115

ISSUE

02 C


PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION

LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER 6.00HOUSE CONNECTION

S

S

5.30

5.50

S

6.00

0 6.0

16.18

13.00

S

6.0 0

6.50

0

30.01

S

5.5

0

6.0

7116 467.1 m²

S

17.01

5.5

0

6.00

5.50

5.50

5.00 5.00

S

S

5.00 S

S

S

S

ARC 15.00 4.50

S

4.50

SA

BRIGANTINE DR (MC13) 4.50 PROJECT

PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.

0

5m

1 : 250 DATUM

DRAWN

CHECKED

AHD

AA

JT

Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com

TITLE

DISCLOSURE PLAN LOT NO. 7116

PROJECT CODE

DRAWING No.

ISSUE

AA006310

LOT-7116

01 C


PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION

5.30

PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER 6.00 HOUSE CONNECTION

LEGEND S

6.50 6.50

13.85

6.50

30.01

30.02

6.50

7117

6.00402.5 m²

6.00

5.50

5.50

5.50 S

S

5.00

5.00 S

S

S

S

ARC 13.00

S

4.50

BRIGANTINE DR (MC13)

4.50 S

PROJECT

PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.

0

5m

1 : 250 DATUM

DRAWN

CHECKED

AHD

AA

JT

Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com

TITLE

DISCLOSURE PLAN LOT NO. 7117

PROJECT CODE

DRAWING No.

ISSUE

AA006310

LOT-7117

01 C


PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION

LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION 6.50

S

5.30

6.50

13.79

6.50

6.50

30.02

30.02

6.50

7118

401.7 m²

6.00

6.00 6.00

5.50 5.50

S

S

S

S

S

5.00

S

ARC 13.00 5.00

BRIGANTINE DR (MC13)

PROJECT

PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.

0

5m

1 : 250 DATUM

DRAWN

CHECKED

AHD

AA

JT

Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com

TITLE

DISCLOSURE PLAN LOT NO. 7118

PROJECT CODE

DRAWING No.

ISSUE

AA006310

LOT-7118

01 C


PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION 6.50

LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION

S

5.30

6.50

15.85

6.50

6.50

6.50

30.02

7119 30.02

462.5 m²

6.00

6.00

6.00

5.50

5.50

5.50 S

S

S

ARC 15.00

S

S

S

5.00 5.00

BRIGANTINE DR (MC13)

5.00

PROJECT

PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.

0

5m

1 : 250 DATUM

DRAWN

CHECKED

AHD

AA

JT

Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com

TITLE

DISCLOSURE PLAN LOT NO. 7119

PROJECT CODE

DRAWING No.

ISSUE

AA006310

LOT-7119

01 C


PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION

5.30

PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION 6.50

LEGEND S

6.50

13.85

6.50

30.02

6.50

30.02

7120 402.6 m²

6.00 6.00

5.50

S

6.00

5.50

5.50

S

S

S

S

S

ARC 13.00

5.00

5.00

BRIGANTINE DR (MC13) PROJECT

PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.

0

5m

1 : 250 DATUM

DRAWN

CHECKED

AHD

AA

JT

Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com

TITLE

DISCLOSURE PLAN LOT NO. 7120

PROJECT CODE

DRAWING No.

ISSUE

AA006310

LOT-7120

01 C


PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION

LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION

S

5.30

6.50

6.50

11.73 6.50

6.50

30.02

30.02

6.00

7121 341.2 m²

6.00 6.00

5.50

S

5.50

5.50

S

S

S

ARC 11.00

S

S

5.00

5.00

BRIGANTINE DR (MC13)

PROJECT

PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.

0

5m

1 : 250 DATUM

DRAWN

CHECKED

AHD

AA

JT

Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com

TITLE

DISCLOSURE PLAN LOT NO. 7121

PROJECT CODE

DRAWING No.

ISSUE

AA006310

LOT-7121

01 C


PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION

LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION

S

5.30

6.50

6.00

6.50

6.50

15.79

6.50

0

6.0

6.00 30.02

7122

30.02

461.6 m²

6.00 0 5.5 5.50 5.50

5.00

S

S

S

S

S

ARC 15.00

S

5.00

SA

BRIGANTINE DR (MC13) 4.50 PROJECT

PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.

0

5m

1 : 250 DATUM

DRAWN

CHECKED

AHD

AA

JT

Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com

TITLE

DISCLOSURE PLAN LOT NO. 7122

PROJECT CODE

DRAWING No.

ISSUE

AA006310

LOT-7122

01 C


S

6.00

PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION

5.30

PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION

LEGEND

6.50

5.00

5.50

17.26 6.50

0

6.0

30.02

30.03

6.00

7123

S

484.0 m²

5.5 0

5.50 5.00 S

S

S

S

S

S

ARC 15.00

4.50

S

SA

BRIGANTINE DR (MC13) 4.50

S

SA PROJECT

PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.

0

5m

1 : 250 DATUM

DRAWN

CHECKED

AHD

AA

JT

Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com

TITLE

DISCLOSURE PLAN LOT NO. 7123

PROJECT CODE

DRAWING No.

ISSUE

AA006310

LOT-7123

01 C


10

20

30

40

50m

1 : 500

LEGEND

EXISTING DEVELOPMENT

PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION

S

PROPOSED LOT GRADING CONTOUR PROPOSED SITE BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION ALTERNATIVE INTERSECTION LAYOUT OPTION

5.30

SERVICES LAYOUT HEREIN IS INDICATIVE ONLY AND IS SUBJECT TO CHANGE DURING DETAILED DESIGN

W

1.50 .00 50 3. 2.200 3.50 0 4.0 4.00

5.00

7103

7102

7105

7106

380.3 m²

379.6 m²

S

518.1 m²

7104

320.0 m²

431.1 m²

321.3 m²

7107

7108

320.5 m²

379.6 m²

402.5 m²

4.50

BRIGANTIN E 5.00

S

FUTE

3.20 .0 0

TG

M DR (

FU WFUTT FUTE

5.00

4.00

Y 4.50

0

4.00

SA 4.00 SA

4.00

SA

4.00

LANEWAY 01

FUTG W FUTT FUTE

4.0

SA

0

FUTG

4.0

C13)

FUTT

LANEWAY 02

W

5.50

4.00 3 3.50 2.50.00 2 1232.50.5 .00 0 1.000

FUTT FUTG FUTE

4.00

SA

4.50 W

4.0

DR

SA

W

W

7115 492.6 m²

5.00 S

SA

GC

0 S

SA

5.00

SA

E

7115

5.50

S

SA

S

SA

7116 467.1 m²

5.50

S

4.50

E

C E

S

7114 7114m² 385.7

7117

401.7 m²

SEAF

7118

462.5 m²

S

0

6.0

7119

402.6 m²

C

S

4.00 S

7120

341.2 m²

5.00

SA

ARIN G WA

S

491.1 m²

7121

461.6 m²

484.0 m²

S

S

7122

7123

4.00

G

0

S

G C

5.5

7113 385.7 m²

6.00

S

E

G C

496.2 m²

7113

0

G

G C

7111

6.50

S

S

S

7112

6.50

5.5

LV

E

7110 319.4 m²

6.50

S

S

S

S

S

7109 6.00 380.5 m²

434.8 m²

\\\\

E

4.00 4.50

6.50

7124

SA

S

4.50S FUTE FUTS

5.50

6.00 G

SA

S

2.00 2.50 3.00 3.50 4.00

FUTE

W FUTT

S

FUTG

5.00

0

SA

4.00

0

W

AVENUE 4.0N 0 CATAMARA

FUTG

W

FUTS

FUTT

MC24

CG

E S CG

0

\\\\

GC

4.50

6.0

1.5

6.00

7101

4.0

SA

FUTS

FUTE

W FUTG

E S

6004

E

S

5.50

SA

4.00

1.50

FUTT

CG

1.00

S

5.00

S

497.9m²

4.50

5.00

S

0

6112

S

S

S

0 342.50

AVENUE

5.0

385.4m²

CATAMARAN

SA

SA

2.00 00 3. 2. 4.450 .00

FUTS W

FUTE

FUTG

4.50

S

E

SA

S

6111

23

MC

S

6110

502.5m²

4.00 4.50

S

C G

S

W

HV

FUTW FUT F FUTUETG

FUTURE PRECINCT H

FUT FUTW FUTG FUTE

FFUUTTW FUTG FUTE

FUT

FUTW FUTG FUTE

FUT

FUTW FUTG FUTE

FUT

FUTW FUTG FUTE

FUT

FUTW FUTG FUTE

FUT

FUTW FUTG FUTE

FUT

FUTW FUTG FUTE

FUT

FUTW FUTGE FUT

FUT

MC23

FUTW FUTTGE FU

FUT FUT G FUTTE FU

FUTE

FUTE

FUTE

FUTE

FUTE

FUTE

FUTE

UTW FFU TF FUTUETG

FUFU T TW FUTG FUTE

T W FU

FUTE

MENT ION EASE

HV

SUBSTATI ON PLINTH

SUBSTAT

FIRE REST

RESTRICT SWIMMING POOL

LV

RICTION ZONE

ION ZONE

HV SUBSTATION PLINTH

T SUBSTATION EASEMEN

ZONE FIRE RESTRICTION

SWIMMING POOL

FUTE

ZONE RESTRICTION

FUTE

T TWFU FU TG FUUTE F

FUTG FUTE

INE T N A

0

6006

LV

E

FUT

Client

Status

Project

ISSUE FOR INFORMATION Scales

Original Size 02

ISSUE FOR CLIENT REVIEW - ROUNDABOUT OPTION ADDED

06/11/20

Height Datum

01

ISSUE FOR CLIENT REVIEW

21/07/20

Grid

Issue

Description

Date 100mm on Original

Filename:

SHELL COVE PRECINT F AND G STAGE-3

Current Issue Signatures

1 : 500

Drawn A. AYSON

A1

Designed

AHD

Checked J. TANAEL

MGA 94

Approved D. PRAJAPATI

Title

OVERALL MARKETING PLAN

Arcadis Australia Pacific Pty Limited Level 16, 580 George St SYDNEY NSW 2000 ABN 76 104 485 289 Tel No: +61 2 8907 9000 Fax No: +61 2 8907 9001 arcadis.com Drawing No.

Project No.

Issue

LOT-FG03-ALL

AA006310

02

Date Plotted: 6 Nov 2020 - 02:11PM File Name: C:\F&G\12DSynergy\LOT-FG03-ALL-aa006310-OverallMarketingPlan.dwg

V1


PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION

5.30

PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION

LEGEND

S

5.50

17.00

5.00

4.50

4.00

S

4.00

6.00

S

6.0

30.03

2 25.5 S

MC25

0

4.00

4.50

7124

S

491.1 m²

4.0

0

0

5.5

5.00

6.4

3 S

S

S

S

ARC 11.95 4.50

4.00

S

SA

BRIGANTINE DR (MC13) 4.50

PROJECT

PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.

0

5m

1 : 250 DATUM

DRAWN

CHECKED

AHD

AA

JT

Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com

TITLE

DISCLOSURE PLAN LOT NO. 7124

PROJECT CODE

DRAWING No.

ISSUE

AA006310

LOT-7124

01 C


Turn static files into dynamic content formats.

Create a flipbook
The Waterfront, Shell Cove - Precinct G Land - Contour Plans by Frasers Property Australia - Issuu