Adaptive Radiotherapy for Bladder Cancer – A Review
Urology
Article
Adaptive Radiotherapy for Bladder Cancer – A Review Authors:
*Jennifer Livschitz,1 Hefei Liu,2 David Schaal,3 Sushil Beriwal3,4 1. Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, USA 2. Department of Radiation Oncology, University of Pennsylvania, Philadelphia, USA 3. Varian Medical Systems Inc, Palo Alto, California, USA 4. Allegheny Health Network Cancer Institute, Pittsburgh, Pennsylvania, USA *Correspondence to jlivschitz@mcw.edu
Disclosure:
Livschitz has declared no conflicts of interest. Liu reports temporary employment at Varian Medical Systems. Schaal reports employment at Varian Medical Systems. Beriwal has a leadership role as the Vice President of Medical Affairs at Varian Medical Systems; reports a grant as an Elsevier consultant; and reports participation in an advisory board at Xoft DSMB.
Support:
This article was supported by Varian, a Siemens Healthineers Company.
Received:
24.10.23
Accepted:
05.12.23
Keywords:
Adaptive, adaptive radiotherapy (ART), bladder preservation, cone-beam CT (CBCT), image-guided radiation therapy, MRI.
Citation:
EMJ Urol. 2023;11[Suppl 1]:2-13. DOI/10.33590/emjurol/10302942. https://doi.org/10.33590/emjurol/10302942.
Abstract Radiotherapy plays an important role in organ preservation for bladder cancer. Delivering radiation accurately can be challenging, in part because the bladder and surrounding organs may change position, volume, and shape between and during the fractions of a treatment course. This variability has been accounted for by increasing the margins around the treatment targets, which can expose more normal tissue to radiation, and increase the likelihood of normal tissue complications. An alternative strategy is to alter, or adapt, the radiotherapy treatment plan to account for such inter-fraction changes, a strategy termed ‘adaptive radiotherapy’ (ART). ART allows smaller target volumes to be treated, and may reduce complications. Approaches to ART include offline adaptation strategies and online strategies, which includes choosing a plan of the day (PoD) based on pre-treatment imaging and magnetic resonance (MR), or with cone-beam CT (CBCT)-guided daily plan reoptimisation. Here, the authors review these ART strategies and trials exploring the dosimetric and clinical benefits of ART relative to non-ART bladder radiotherapy.
2
Urology
●
January 2024
●
Cover Image © SeanPavonePhoto / AdobeStock
Article
INTRODUCTION Bladder cancer is the sixth most common cancer, with an estimated 82,290 new cases in 2023.1 Radiation therapy has many clinical applications for bladder cancer, including the opportunity to cure cancer with organ preservation as part of trimodality strategy for muscle-invasive disease, and in the palliative setting for symptomatic local disease.2,3 Radiotherapy has been used to treat patients with bladder cancer since the 1920s, with the first international consensus guidelines published in July 1983, following the First International Symposium of Tumors of the Urinary Bladder in Paris, France.4-6 In the past few decades, the techniques used to deliver radiation therapy for bladder cancer have evolved significantly to overcome challenges related to daily changes in the size, shape, and position of the bladder.7,8 For example, with conventional radiation, large margins were added to target volumes to account for the dynamic volume of the bladder throughout the course of treatment, which could result in higher local failure rates from geographic misses, and increased toxicities because of increased exposure of normal tissue.9 With the development of new technology, ART has emerged as a promising solution to improve target precision, with the potential to improve clinical outcomes. The aim of this review is to: review how advances in technology and treatment techniques have impacted the delivery of radiation for bladder cancer; discuss the role of ART, and potential dosimetric and clinical advantages of this emerging treatment strategy; and explore future directions for adaptive radiation for bladder cancer.
DISCUSSION Impact of Evolving Technology on Radiation Delivery for Bladder Cancer
Prior to the development of CT scans, radiation treatment plans were initially designed based on two-dimensional imaging or plain X-ray films. The invention of CT imaging revolutionised radiation treatment delivery by providing three-dimensional visualisation of treatment isodose lines, termed 3D conformal radiation therapy. Furthermore, the integration of advanced imaging capability with medical
linear accelerators brought forth two major technological advancements in radiation treatment. Firstly, image-guided radiation therapy emerged, and provided the treatment team with the ability to frequently reimage the patient with CBCT scans during the course of radiation treatment, to verify the position of the target, improving accuracy and precision of treatment delivery. Secondly, intensitymodulated radiation therapy (IMRT) was developed as an advanced form of 3D conformal radiation therapy, in which the intensity of each beamlet within a given treatment beam can be modulated with its own individual intensity level, leading to the construction of a complex pattern of dose delivery. This technique yields a highly conformal dose distribution, with improved precision of dose to target, and reduction of dose delivered to normal tissue.10 The widespread availability of CBCT imaging enabled daily visualisation of the bladder target throughout treatment delivery. This ability to visualise the bladder target every day prior to treatment made it clear to treating physicians that the bladder size and shape could change drastically between sessions, such that the ability of the original treatment plan, based on the initial planning CT scan, to adequately cover the target and spare surrounding normal tissues, could be compromised. Such observations led to the development of ART techniques. ART provides the opportunity to individualise and optimise treatment through the utilisation of images acquired either during, or immediately prior to, the treatment delivery, to modify the treatment plan based on specific anatomical patient factors. The rationale to support adaptive strategies is to more closely match the treatment volume created by the physician to the target volume revealed in today’s image. This results in an improvement in accuracy of treatment dose delivery to the target, and minimisation of dose to normal tissue. In the remainder of this review, the authors will discuss different techniques available for bladder cancer ART, discuss dosimetric and clinical advantages to ART, and explore future directions.
Important Radiation Planning Definitions Before there can be more detailed discussion, it is important to define key terms specific to radiation treatment planning that will be utilised
Creative Commons Attribution-Non Commercial 4.0
●
January 2024
●
Urology
3
Article
throughout this article. There are three types of target volumes that are used for radiation planning: gross tumour volume (GTV), clinical target volume (CTV), and planning target volume (PTV). The GTV describes the volume that can be seen and measured on a scan; the CTV describes the suspected microscopic extension of disease based on biologic data specific to disease site; and the PTV is a margin of volume added to account for uncertainty in targeting, for example, due to organ movement. In general, radiation oncologists begin by creating a GTV to define the gross visible disease. A margin is then added to the GTV to create a CTV that accounts for microscopic extension, and an additional margin is added to create a PTV that accounts for motion. A second key concept in radiation treatment planning is minimisation of dose to healthy tissue near the target volume. Based on the target of interest, there are specific healthy tissues termed ‘organs-at-risk’ (OAR) that are near the target volume, and are likely to receive some radiation dose. When discussing radiation to the bladder, the rectum and the small bowel are the two key important OAR, and as a result, dose to those areas is carefully measured and monitored during radiation treatment. One key metric for the strength of a specific radiation technique is a reduction in healthy tissue volume that receives a high dose of radiation. When referring to volume receiving a certain dose of radiation, an acronym such as V50 Gy may be used, which means volume receiving a dose of at least 50 Gy. Understanding these definitions is important, as adaptive techniques in bladder cancer are commonly evaluated based on their ability to decrease the size of PTV margins, leading to reduction in V50 Gy delivered to the rectum, and V45 Gy delivered to the small bowel.
Adaptive Radiotherapy: Available Techniques
There are many different adaptive techniques reported in the literature, which can be split up into offline strategies, such as composite ART, and online strategies, including PoD and MR- or CBCT-guided daily plan re-optimisation (Figure 1). An offline composite ART plan involves using CBCT imaging from the first week of treatment to create one new adaptive plan based on
4
Urology
●
January 2024
●
the changes in patient’s anatomy seen during the week with PTV margin derived from the scans. Compared with conventional techniques, composite ART plans allow for the creation of a planning target volume that is more representative of the patient’s bladder size, shape, and position during treatment, leading to reduced PTV volume, higher conformity index (that is, the degree to which the treatment plan conforms to the target), and reduced toxicity, with similar target volume coverage.11,12 However, one primary limitation of offline ART is it can only provide a reduction in systematic error, and cannot account for unpredictable daily changes in bladder volume. The PoD ART technique is one of the earliest online adaptive strategies, and therefore, the most studied and represented approach in the literature. This technique is conducted in two stages. Firstly, during the treatment planning stage, a library of three to five different plans is created, based on probabilistic, populationbased margins for intra-fraction variation in bladder volume.13 Then, once treatment begins, CBCT images are acquired daily with the patient on the treatment table to assess patient anatomy, and a plan is selected in real time from the library that best represents the patient’s current anatomy.14 One specific variation to this approach further individualises the treatment by utilising CBCT images from the first week of treatment to generate a personalised library of plans, with margins based on the patient’s own bladder volume variability, rather than population-based margins.15 While this technique confers many of the dosimetric and clinical advantages that will be discussed in detail in this article, it is important to consider several limitations, including observer variability in plan selection, the potential that there is no suitable plan, increased treatment time, and logistical implementation error leading to geographic misses.12 More recently, the introduction of online reoptimisation using MRI-guided (MRgRT) or CBCT-guided systems has addressed some of the limitations of the PoD approach. MRI can improve the soft tissue contrast to refine target and OAR delineation.16 In addition, MRgRT can observe and account for intra-fractional bladder variability through real-time motion mitigation. The bladder is relatively mobile, and increases in size
Creative Commons Attribution-Non Commercial 4.0
Article
Figure 1: Workflow diagrams for conventional (non-adaptive) radiotherapy, plan-of-the-day adaptive radiotherapy, and online adaptive radiotherapy.
Online adaptive RT
Patient consultation
Simulation (planning) CT scan
Treatment plan creation
Image guidance
Autocontouring/ correction
Conventional (non-adaptive) RT
PoD adaptive RT
Patient consultation
Patient consultation
Simulation (planning) CT scan
Simulation (planning) CT scan
Treatment plan creation
Treatment plan creation
Plan library creation
Imageguided treatment
Image guidance/ selection of plan from library
Follow-up
Plan reoptimisation Image-guided treatment
Image-guided treatment Follow-up
Follow-up
The arrows indicate processes that are repeated every session throughout the treatment course. PoD: plan-of-the-day; RT: radiotherapy.
Creative Commons Attribution-Non Commercial 4.0
●
January 2024
●
Urology
5
Article
non-uniformly with filling. The magnitude of this change is rarely consistent, and current drinking protocols, catheterisation, dietary modifications, and laxatives have not shown consistent results in reducing bladder size variation.17,18 Thus, stochastic variation in organ filling, deformation, and peristaltic motions of the target and OAR can be monitored prior to MRgRT session, and the treatment plan adjusted accordingly.19 However, this approach is not without its own limitations, one of which is longer treatment times in the region of 30–40 minutes or longer.20 There have been two MR-guided linear accelerators introduced to the market, and in clinical use over the last decade, the ViewRay MRIdian® (GenesisCare, Sydney, Australia) and the Elekta Unity (Elekta, Stockholm, Sweden). Although they differ in some ways, they both use MRI for patient setup, and to track changes in the target in real time during the procedure. The ViewRay company recently declared bankruptcy and subsequently ceased operations, so this device is no longer in clinical operation. In part as an effort to minimise the time and resources necessary to conduct daily plan re-optimisation, the Ethos™ CBCT-guided ART system (Varian, a Siemens Healthineers Company, Palo Alto, California, USA) was developed more recently to take advantage of artificial intelligence (AI) and machine learning to optimise the ART workflow.21 This system has three key components: an automated treatment planning system for plan generation, online ART planning system with integrated quality assurance, and offline monitoring treatment solution.22,23 During treatment planning, the physician defines clinical goals that take into account fractionation (that is, how many sessions, or fractions, are used to deliver the total dose), and dose constraints on targets and OAR. The system applies the prioritised list of clinical goals and automatically generates a treatment plan. Once a treatment plan has been generated, online ART workflow uses iterative CBCT, or enhanced quality CBCT images, as input into an AI-driven program, which can re-calculate and re-optimise a new plan based on updated anatomy of that day. Plans can then be evaluated by the physician to select the best treatment plan.22 Although in a broad sense the on table ART workflow for the MRguided and CT-guided systems are the same, treatment sessions are generally shorter using a CT-guided system. Studies have shown sessions
6
Urology
●
January 2024
●
conducted within a 15–25-minute time slot, although many variables may affect workflow timing, and determine the duration of treatment.23,24 In the setting of these various techniques, ART has several potential advantages over conventional, nonadaptive radiation, including improved dosimetric metrics, such as better target coverage and decreased dose delivery to healthy tissue, and clinical outcome measures, including disease control and toxicity mitigation. From the perspective of the patient, ART and non-ART procedures differ minimally. Patient instructions would include explaining the reason for the waiting time during the adaptation phase of the daily session (indicated in Figure 1 by the ‘Autocontouring/correction’ and ‘Plan reoptimisation’ stages of the treatment process) and re-emphasising the need to remain still as possible throughout. In the remainder of this review, the authors will discuss dosimetric benefits and clinical outcomes reported in the literature. A summary of findings from included studies can be found in Table 1.
Adaptive Radiotherapy: Dosimetric Benefit
There are many studies that report dosimetric benefits through improved PTV and CTV coverage using the PoD approach.13,15,25-28 Specifically, a British study looking at 20 patients with bladder cancer who underwent PoD ART found that online CBCT-assisted plan selection techniques allowed for 15 mm margins to be safely reduced to 10 mm.13 Another study in France looking at data from 10 patients treated for localised muscle invasive bladder cancer with PoD ART demonstrated a greater than 97% CTV coverage.25 Furthermore, a study examining patterns of bladder wall motion and validating a specific novel adaptive planning method called adaptive-predictive organ localisation (A-POLO) found that this strategy improved target coverage by up to 24%, increasing the percent of fractions delivered correctly from 49% to 73%.26 A-POLO is a unique version of PoD ART in which CT planning scans are taken at 0, 15, and 30 minutes after voiding, to create a ‘library’ of plans based on patient-specific bladder filling patterns. Finally, three studies conducted by Vestergaard and colleagues15,27,28 together support an improvement in PTV coverage, with no target
Creative Commons Attribution-Non Commercial 4.0
Article
Table 1: Trials of daily adaptive radiotherapy for bladder cancer, including the procedure used for adaptation, state of bladder filling at treatment session start, number of patients involved, and clinical outcomes and key findings.
Author
Year Adaptive Bladder Procedure Filling Type
Number of Patients
Outcome/Key Findings
Astrom et al.23
2021
On-table CBCTbased adaptation
Empty bladder
23
- Median adaptive procedure time: 13.9 min - Median volume reduction in PTV-T: 33.9% - Median reduction in bowel bag V45 Gy of 18.8% and rectum V50 Gy of 70.7% - Large reductions in treatment volumes and doses to OARs, while ensuring target coverage
Burridge et al.13
2006
PoD adaptation
Empty bladder
20
- The average small bowel volume spared was 31 cc - Online CBCT-assisted plan can significantly reduce dose to small bowel - CBCT allows 15 mm margins used in some directions to be safely reduced to 10 mm
Cabaille et al.25
2021
PoD adaptation
Empty bladder
10
- Greater than 97% CTV coverage - Significantly improved sparing of the small bowel (V45 Gy 43.4 cc versus 57.6 cc for the non-adaptive approach) - Mean follow-up of 2.94 years, three CTCAE Grade 3 toxicities, no Grade 4 toxicities - 2-year OS and PFS were 65.5% and 45.7%, respectively
Canlas et al.29
2016
PoD adaptation
Empty bladder
8
- Smallest PTV using 1.0 cm margins was selected 70% of the time - Three RTs demonstrated agreement for daily PTV, choosing identical plan-of-day for 51% of all CBCT - Average volume of bowel bag (45 Gy and 50 Gy) and normal tissue receiving 95% prescription dose was significantly lower for the plan-of-day versus conventional
Chen et al.30
2018
On-table CBCTbased adaptation
Empty bladder
24
- The purpose of this study was to identify the number of CBCT image sets to produce the optimal personalised PTV margins for whole bladder and partial bladder radiation therapy - Using the contours from the images of the first five daily fractions decreased the irradiated volume, reduced delineation workload, and reduced the superior and posterior borders for whole bladder radiation
Foroudi et al.11
2011
PoD adaptation
Empty bladder
27
- Bladder volume decreased with time or fraction number - Small, medium, large, and conventional plans were used in 9.8%, 49.2%, 39.5%, and 1.5% of fractions, respectively - Mean volume of normal tissue receiving a dose >45 Gy was 29% less with adaptive RT - Mean volume of normal tissue receiving >5 Gy was 15% less with adaptive RT
Hafeez et al.31
2016
PoD adaptation
*Bladder filling protocol
18
- Rate of intrafraction filling at the start of treatment (i.e., Week 1) was 4.0±4.8 mL/min, and at end of radiation therapy (i.e., Week 5 or 6) was 1.1±1.6 mL/min. - The mean dose received by 98% volume of the tumour boost and bladder as assessed on the post-treatment CBCT scan was 97.07%±2.10% and 99.97%±2.62%. - Median follow-up of 19 months, no muscle-invasive recurrences had developed - Two patients had CTCAE late toxicity (both Grade 3 cystitis) at 5.3 months (resolved) and 18 months after radiation therapy
Creative Commons Attribution-Non Commercial 4.0
●
January 2024
●
Urology
7
Article
Table 1 continued.
Author
Year Adaptive Bladder Procedure Filling Type
Number of Patients
Outcome/Key Findings
Hafeez et al.32
2017
PoD adaptation
*Bladder filling protocol
55
- GU/GI CTCAE Grade 3 toxicity: 18% and 4% - Greater than Grade 3 toxicity at 6 months, 12 months: 6.5% and 4.3% - Local control: 92% - Incidence local progression at 1 year and 2 years was 7% and 17%, respectively - OS at 1 year was 63% - Good local control with acceptable toxicity in patients who cannot get radical bladder treatment
Huddart et al.33
2023
PoD adaptation
WBRT: empty bladder DART/SART: *bladder filling protocol
345
RAIDER Results - Median follow-up for patients treated in 32 fractions: 38 months - Median follow-up for patients treated in 20 fractions: 42.1 months - 58% fractions delivered to SART and DART groups used small or large POD - RT-related G ≥3 in 20 fractions DART was 1/58 and in 32 fractions DART was 0/57 - 3-month local control was achieved in 86% WBRT, 85% SART, and 89% DART - 2-year survival was 79% WBRT, 74% SART, and 80% DART - CTCAE late G ≥3 toxicity was low in all treatment groups
Huddart et al.34
2021
PoD adaptation
*Bladder filling protocol
65
HYBRID Results - Median follow-up time was 38.8 months - CTCAE ≥G3 non-GU toxicity rates were 6% for the adaptive planning group, and 13% for the standard planning group - LCR: 81.3% - Weekly ultra-hypofractionated 36 Gy/6 fraction radiation therapy is safe, and provides good local control rates in this older patient population
Hunt et al.20
2020
On-table MR-guided adaptation
Empty bladder
5
- MRI-guided whole bladder radiotherapy was feasible using a 1.5 T MR-linac - Each fraction was re-contoured, planned, and delivered in online workflow within 45 min - Intra-fraction bladder filling did not compromise target coverage
Jo et al.35
2022
PoD adaptation
Empty bladder
19
- Bladder was out of the PTV range in 2.9% of scans (12/408) - The 1-year and 2-year OS rates were 88.2% and 63.7%, respectively - No CTCAE Grade 3 or higher RT-related adverse events
Kron et al.14
2010
PoD adaptation
Empty bladder
27
- Compared to conventional radiotherapy, the reduction in margin and choice of best plan of three for the day resulted in a lower total dose in most patients, despite daily volumetric imaging
Lalondrelle et al.26
2011
PoD adaptation
Empty bladder
15
- A need for adaptive planning was demonstrated in 51% of fractions, and 73% of fractions would have been delivered correctly using A-POLO (a novel adaptive planning method) - Target coverage improved by 24%, from 49% to 73%, of fractions delivered correctly
Lutkenhaus et al.36
2015
PoD adaptation
Full and empty bladder
10
- Lymph node coverage improved using an adaptive strategy - The full bladder strategy spared the healthy part of the bladder from a high dose - Average bowel cavity V30 Gy and V40 Gy significantly reduced with 60 and 69 cc bowel fill, respectively - Daily plan selection compared to a non-adaptive strategy yielded similar bladder coverage and improved coverage for lymph nodes, with a significant reduction in bowel cavity V30 Gy and V40 Gy only, while other sparing was limited
8
Urology
●
January 2024
●
Creative Commons Attribution-Non Commercial 4.0
Article
Table 1 continued.
Author
Year Adaptive Bladder Procedure Filling Type
Number of Patients
Outcome/Key Findings
Murthy et al.37
2019
PoD adaptation
Bladder comfortably full for patients undergoing SIB. Otherwise, bladder empty
106
- At a median follow-up of 26 months, 3-year LRC, DSF, and OS were 74.3, 62.9, and 67.7%, respectively - 82% of patients retained disease-free bladder - RTOG Grade III/IV acute GU and GI toxicities were 7.5% and 0.0%, respectively - Late GU/GI toxicities were 6.5% and 3.8%, respectively - OS, DSF, LRC, and Grade III/IV GU/GI toxicities did not differ significantly with dose escalation
Murthy et al.38
2016
PoD adaptation
Bladder comfortably full for patients undergoing SIB. Otherwise, bladder empty
44
- At median 30 months, the 3-year LRC, DFS, and OS were 78%, 66%, and 67%, respectively - The bladder preservation rate was 83% - LRC (87% versus 68%; P=0.748) and OS (74% versus 60%; P=0.36) rates were better in patients receiving dose escalation - Instances of acute and late RTOG Grade 3 GU toxicity were seen in 5 (11%) and 2 (4%) patients, respectively - There was no acute or late RTOG Grade 3 or higher GI toxicity
Murthy et al.39
2011
PoD adaptation
Bladder comfortably full for patients undergoing SIB. Otherwise, bladder empty
10
- Coverage of anterior and superior walls required larger margins than other walls - Maximum geographical miss was noted for the superior (13.8%) and anterior walls (10.3%) - Median follow-up of 13.2 months - All patients had complete response of bladder tumour; one patient had pelvic node recurrence at 12 months - All patients tolerated well; one patient with haematuria (RTOG Grade 3 toxicity), resolved after 6 weeks
Sibolt et al.22
2021
On-table CBCTbased adaptation
Not specified
3
- AI-oART has similar PTV coverage and OAR doses compared to institution reference - Greater than 75% of AI-segmentations required none or minor editing; adapted plan was superior in 88% of the time - The treated bladder patients demonstrated a 42% median primary PTV reduction, indicating a 24–30% reduction in V45 Gy to the bowel cavity, compared to non-ART
Vestegaard et al.15
2010
PoD adaptation
Empty bladder, then drank approximately 27 oz water
10
- Compared three ART strategies that were all based on daily selection of the most suitable plan from a library consisting of three IMRT-plans corresponding to a small, medium, and large target volume - ART method A utilised population-based margins, while methods B and C used the bladder as seen on CBCTscans from the first week of treatment; method B without delineation of the bladder on CBCT; and method C with delineation of the bladder. - Mean ratios of the volumes receiving 57 Gy or more (corresponding to 95% of prescribed dose) for methods A, B, and C were 0.66, 0.67, and 0.67, respectively, when compared to the non-adaptive plan
Vestegaard et al.27
2013
PoD adaptation
Empty bladder
7
- Compared the normal tissue sparing potential of two ART strategies: daily plan selection (PlanSelect) and daily plan re-optimisation (ReOpt) - PlanSelect strategy involves the most suitable plan (out of three) based on the pre-treatment CBCT was selected; the daily ReOpt strategy involves re-optimised plans based on the CBCT from each daily fraction - Significant normal tissue was achieved with both ART approaches, with ReOpt better - Compared to non-adaptive RT, the volume receiving more than 57 Gy (corresponding to 95% of the prescribed dose) was reduced to 66% (range 48–100%) for PlanSelect, and to 41% (range 33–50%) for ReOpt
Creative Commons Attribution-Non Commercial 4.0
●
January 2024
●
Urology
9
Article
Table 1 continued.
Author
Year Adaptive Bladder Procedure Filling Type
Number of Patients
Outcome/Key Findings
Vestegaard et al.28
2014
20
- Bladder contours from the CBCTs acquired in the first four fractions were used to create a patient-specific library of three plans, corresponding to a small, medium, and large size bladder - Small, medium, and large size plans were used almost equally often - The median volume ratio of the course-averaged PTV relative to the non-adaptive PTV was 0.70
PoD adaptation
Empty bladder
AI-oART: artificial intelligence - online adaptive radiotherapy; ART: adaptive radiotherapy; CBCT: conebeam CT; CTCAE: Common Terminology Criteria for Adverse Events; CTV: clinical target volume; DART: dose-escalated adaptive tumour boost radiotherapy; DFS: disease-free survival; GI: gastrointestinal; GU: genitourinary; IMRT: intensity-modulated radiation therapy; LRC: locoregional control; MR: magnetic resonance; OAR: organs at risk; OS: overall survival; PFS: progression-free survival; PoD: plan-of-the-day; PTV: planning target volume; PTV-T: primary PTV; RT: radiotherapy; RTOG: Radiation Therapy Oncology Group; SART: standard dose adaptive tumour-focused RT; SIB: simultaneous integrated boost; V## Gy: volume of of tissue that is getting ## Gy of radiation dose (i.e., ‘bowel cavity V45 Gy was 60 cc’ means the volume of bowel cavity receiving 45 Gy of radiation was 60 cc); WBRT: standard whole bladder RT. *After voiding, the patients drank 350 mL of water, 30 minutes after which a non-contrast-enhanced planning CT scan was performed (CT30), followed 30 minutes later by a second planning CT scan (CT60). No bladder emptying or drinking was permitted between the two scans.
compromise, improved target conformity, and reduction in PTV by 183 cm3 with PoD approach compared with non-adaptive techniques.
conformity index, that yields improved target coverage and less dose to OAR, compared with conventional planning.
Another important advantage of ART is the sparing of normal tissue dose, and subsequent reduction in treatment toxicity. Many studies report improved sparing of bowel dose volume with ART.11,14,25,29,30,35,36 Canlas et al.29 compared dosimetric results between PoD ART and conventional treatment, and found that average volume of bowel bag and normal tissue receiving 95% of prescription dose was significantly lower for PoD versus conventional (p<0.01). Additionally, Cabaillé et al.25 reported a 43.7% average volume of healthy tissue spared with a 14.2 cc absolute reduction in small bowel V45 Gy, and 1.7 cc absolute reduction rectal V50 Gy for the adaptive versus the standard approach. Finally, Foroudi et al.11 demonstrated that more normal tissue was irradiated using conventional CTV planning compared with ART. More specifically, they showed that ART had 29% less mean volume of normal tissue receiving greater than 45 Gy. Together, these data provide compelling evidence that bladder ART strategies lead to a better
While data on CBCT-guided, AI-driven ART are more limited than PoD, there is evidence to support even better dosimetric outcomes with this newer technology. A study looking at pre-treatment planning for 39 pelvic cases, 100 online ART simulations, and five clinical online ART patients conducted on Ethos™ found that auto-generated treatment plans had similar PTV and OAR doses, with more than 75% AI segmentations requiring no or minor editing, and adaptive plan superiority in 88% of cases.22 Furthermore, the workflow for the first five treated patients had a total procedure time of 17.6 min, with 42% median primary PTV reduction, and 24–30% reduction in V45 Gy to the bowel cavity, compared with nonART.22 Additionally, a study which analysed 297 fractions delivered with online ART full re-optimisation of anatomy showed a median online ART procedure time of 13.9 min, 33.9% median PTV volume reduction, 18.8% median reduction of V45 Gy to the bowel bag, and 70.7%
10
Urology
●
January 2024
●
Creative Commons Attribution-Non Commercial 4.0
Article
median reduction of V50 Gy to the rectum.23 Overall, the data suggest that CBCT-guided online ART is feasible for patients with bladder cancer, AI-driven solutions are time-efficient, and this technique translates to PTV reduction and reduced dose to OAR.
Adaptive Radiotherapy: Clinical Outcomes
As discussed above, significant dosimetric improvements are achieved with the use of ART in urinary bladder irradiation. However, what is more important is whether these advances translate into improved clinical outcomes. Clinical outcomes can be split into two categories: disease control and toxicities. From a disease control perspective, there is evidence to support good local control, overall survival (OS), and progression-free survival (PFS) with online ART techniques. A French clinical study of 10 patients with muscle invasive bladder cancer undergoing PoD ART with a median follow-up of 2.94 years showed 2-year OS and PFS were 65.5% and 45.7%, respectively. Two out of the 10 patients had locoregional relapse, while another three patients developed metastatic diseases.25 Hafeez et al.31 reported a group of 18 patients with muscle-invasive bladder cancer of any histologic subtype treated with whole bladder to 52 Gy and simultaneous integrated boost to the tumour to 70 Gy in 32 fractions. In this study, median follow up was 19.0 months, with no evidence of recurrence.31 The same group in London, UK, also reported on 55 patients with T2-T4aNx-2M0-1 bladder cancer who were treated with 36 Gy in 6-weekly fractions and demonstrated 92% local control with OS of 63% at 1 year.32 Furthermore, several single arm studies conducted between 2011–2022 have reported similar survival rates.35,37-39 In addition, Jo et al.35 described eight of 19 patients developed local recurrence at 1 year post-treatment. Murthy et al. reported a 3-year locoregional control rate of 78%.38 Prior to 2021, there were no randomised control data comparing standard, non-adaptive strategies with ART for bladder cancer. In the last decade, two protocols were developed to address this gap in the literature. The HYBRID protocol compared a single-standard plan (non-adaptive) to adaptive planning in patients with T2-T4aN0M0 muscle invasive bladder cancer receiving 36 Gy in 6-weekly fractions.
This study enrolled 65 patients with a median follow-up time of 38.8 months, and found a local control rate of 81.3%.34 Furthermore, at the 2023 American Society of Clinical Oncology (ASCO) meeting, preliminary data from the RAIDER protocol, which compared standard whole bladder radiotherapy to standard dose adaptive tumour-focused radiotherapy and doseescalated adaptive tumour-focused radiotherapy in 325 patients with T2-T4aN0M0 unifocal muscle invasive bladder cancer, were presented. This abstract reported local control rates of whole bladder, standard dose adaptive tumourfocused, and dose-escalated adaptive tumour focused radiotherapy were 86%, 85%, and 89%, respectively, and 2-year survival rates were also similar among the three treatment groups.33 The dosimetric benefits of sparing normal tissue translate into low rates of significant Grade 3 and 4 toxicity. The toxicity criteria of the Radiation Therapy Oncology Group (RTOG) and the European Organization for Research and Treatment of Cancer (EORTC) were described in the referenced editorial.40 In general, side effects from radiation are considered in the context of acute and late toxicity in the specific location of treatment. Given the location of the bladder in the pelvis, the most common side effects are gastrointestinal (GI) and genitourinary. In the acute setting, common side effects include fatigue, increased frequency or urgency of urination, and change in frequency or quality of bowel habits, including diarrhoea. In the longer term, toxicity could include cystitis, GI bleeding, or GI/genitourinary obstruction, including urinary stricture.41,42 Delving into toxicity data, Cabaillé et al.25 reported Grade 3 toxicities in three patients, but no Grade 4 toxicities, and Hafeez et al.31 reported Grade 3 toxicity in two patients at 5.3 months and at 18.0 months after receiving radiation therapy.31 The other single arm studies report Grade 3 toxicity rates up to 18%, with no Grade 4 toxicity.32,35,37-39 When looking at data from the two randomised control trials, RAIDER reported only one case of Grade 3 radiotherapyrelated toxicity in patients in the adaptive arm,33 and HYBRID reported Grade 3+ toxicity rates of 6% with adaptive techniques compared with 13% in standard radiation.34
Creative Commons Attribution-Non Commercial 4.0
●
January 2024
●
Urology
11
Article
FUTURE DIRECTIONS This review summarises data that have shown improvements in radiotherapy by reducing dose to normal tissue, improving target coverage, and potentially enhancing clinical outcomes. However, most of the current existing data are based on retrospective or small sample size single arm cohort studies, with limited larger scale prospective data on clinical outcomes. Currently, there are nine ongoing clinical trials around the world investigating clinical outcomes of bladder ART, including two prospective trials comparing intestinal toxicity ART and non-adaptive IMRT (NCT05295992, NCT05700227);43,44 one trial in Canada looking at feasibility, treatment plan quality, and toxicity of ART approach for bladder and prostate cancer (NCT03909893);45 one trial in the UK determining maximum tolerated dose of external beam radiation therapy delivered as tumour boost in patients who have undergone transurethral bladder resection for muscle invasive bladder cancer (NCT01124682);46 and three additional trials studying feasibility, local control, and toxicity of various ART techniques (NCT01810757, NCT01000129, NCT05833867).4749 Furthermore, there are two ongoing clinical trials investigating clinical outcomes and patient-reported outcomes with the use of
References 1.
2.
3.
4.
5.
12
National Cancer Institute.Cancer Stat Facts: Bladder Cancer. Available at: https://seer.cancer. gov/statfacts/html/urinb.html. Last accessed: 10 February 2023. Premo C et al. Trimodality therapy in bladder cancer: who, what, and when? Urol Clin North Am. 2015;42(2):169-80. Duchesne GM et al. A randomized trial of hypofractionated schedules of palliative radiotherapy in the management of bladder carcinoma: results of medical research council trial BA09. Int J Radiat Oncol Biol Phys. 2000;47(2):379-88. Bladder cancer. Part B: Radiation, local and systemic chemotherapy, and new treatment modalities. Proceedings of the First International Symposium on Tumors of the Urinary Bladder. Paris, July 4-6, 1983. Prog Clin Biol Res. 1984;162B:1-453. Morson AC. Discussion on
Urology
●
EthosTM CBCT-based ART in bladder cancer (NCT05295992, NCT05700227).43,44 These studies are designed to demonstrate meaningful improvements in treatment-related side effects by comparing ART techniques with standard of care non-adaptive IMRT plans.
CONCLUSION The development of ART treatment planning techniques for bladder radiation therapy has emerged as a promising solution to improve treatment delivery precision in the setting of daily changes in a patient’s bladder anatomy throughout the treatment course. There are many ART techniques reported in the literature, each with their own unique advantages and disadvantages. With the ability to adjust and modify treatment plans prior to delivery, ART provides dosimetric gains, such as improved target coverage and decreased dose to normal tissue, and clinical benefits, such as improved local control and decreased toxicity. Ongoing prospective trials will provide stronger, more robust clinical data on ART for bladder cancer, to better define clinical outcomes in terms of disease control, toxicity, and patient-reported outcomes.
radiotherapy and x-ray therapy in diseases of the bladder and prostate. Proc R Soc Med. 1925;18(Sect Urol):22. 6.
Rigdon RL. Treatment of bladder tumors by radiation and fulguration. Cal State J Med. 1921;19(6):243-4.
7.
Thariat J et al. Image‐guided radiation therapy for muscle‐ invasive bladder cancer. Nat Rev Urol. 2012;9(1):23-9.
8.
Arthur C et al. Delivering adaptive radiotherapy to the bladder during radical treatment. J Radiother Pract. 2013;12(2):195-202.
9.
Kibrom AZ, Knight KA. Adaptive radiation therapy for bladder cancer: a review of adaptive techniques used in clinical practice. J Med Radiat Sci. 2015;62(4):277-85.
10. Taylor A, Powell MEB. Intensitymodulated radiotherapy--what is it? Cancer Imaging. 2004;4(2):6873.
January 2024
●
11. Foroudi F et al. Online adaptive radiotherapy for muscle-invasive bladder cancer: results of a pilot study. Int J Radiat Oncol Biol Phys. 2011;81(3):765-71. 12. Collins SD, Leech MM. A review of plan library approaches in adaptive radiotherapy of bladder cancer. Acta Oncol. 2018;57(5):566-573. 13. Burridge N et al. Online adaptive radiotherapy of the bladder: small bowel irradiated-volume reduction. Int J Radiat Oncol Biol Phys. 2006;66(3):892-7. 14. Kron T et al. Adaptive radiotherapy for bladder cancer reduces integral dose despite daily volumetric imaging. Radiother Oncol. 2010;97(3):485-7. 15. Vestergaard A et al. A comparison of three different adaptive strategies in image-guided radiotherapy of bladder cancer. Acta Oncol. 2010;49(7):1069-76. 16. Njeh CF. Tumor delineation: the weakest link in the search for accuracy in radiotherapy. J Med
Creative Commons Attribution-Non Commercial 4.0
Article
Phys. 2008;33(4):136-40. 17. Dees-Ribbers HM et al. Inter- and intra-fractional bladder motion during radiotherapy for bladder cancer: a comparison of full and empty bladders. Radiother Oncol. 2014;113(2):254-9. 18. Turner SL et al. Bladder movement during radiation therapy for bladder cancer: implications for treatment planning. Int J Radiat Oncol Biol Phys. 1997;39(2):35560. 19. Hijab A et al. MR-guided adaptive radiotherapy for bladder cancer. Front Oncol. 2021;11:637591. 20. Hunt A et al. Feasibility of magnetic resonance guided radiotherapy for the treatment of bladder cancer. Clin Transl Radiat Oncol. 2020;25:46-51. 21. Liu H et al. Review of cone beam computed tomography based online adaptive radiotherapy: current trend and future direction. Radiat Oncol. 2023;18(1):144. 22. Sibolt P et al. Clinical implementation of artificial intelligence-driven cone-beam computed tomography-guided online adaptive radiotherapy in the pelvic region. Phys Imaging Radiat Oncol. 2020;17:1-7. 23. Åström LM et al. Online adaptive radiotherapy of urinary bladder cancer with full re-optimization to the anatomy of the day: Initial experience and dosimetric benefits. Radiother Oncol. 2022;171:37-42. 24. Archambault Y et al. Making online adaptive radiotherapy possible using artificial intelligence and machine learning for efficient daily re-planning. Med Phys Int J. 2020;8(2):77-86. 25. Cabaillé M et al. [Plan of the day adaptive radiotherapy for bladder cancer: dosimetric and clinical results]. Cancer radiotherapie. 2021;25(4):308-315. (In French). 26. Lalondrelle S et al. Adaptivepredictive organ localization using cone-beam computed tomography for improved accuracy in external beam radiotherapy for bladder cancer. Int J Radiat Oncol Biol Phys. 2011;79(3):705-12. 27. Vestergaard A et al. Adaptive plan selection vs. re-optimisation in radiotherapy for bladder cancer: a dose accumulation comparison. Radiother Oncol. 2013;109(3):45762. 28. Vestergaard A et al. Normal tissue sparing in a phase II trial on daily adaptive plan selection in radiotherapy for urinary
bladder cancer. Acta Oncol. 2014;53(8):997-1004.
cancer using helical tomotherapy. Radiother Oncol. 2011;99(1):55-60.
29. Canlas R et al. Assessment of adaptive margins using a single planning computed tomography scan for bladder radiotherapy. J Med Imaging Radiat Sci. 2016;47(3):227-34. 30. Chen S et al. Efficient and effective personalization of ptv margins during radiation therapy for bladder cancer. J Med Imaging Radiat Sci. 2018;49(4):420-7. 31. Hafeez S et al. Prospective study delivering simultaneous integrated high-dose tumor boost (≤70 Gy) with image guided adaptive radiation therapy for radical treatment of localized muscle-invasive bladder cancer. Int J Radiat Oncol Biol Phys. 2016;94(5):1022-30. 32. Hafeez S et al. Clinical outcomes of image guided adaptive hypofractionated weekly radiation therapy for bladder cancer in patients unsuitable for radical treatment. Int J Radiat Oncol Biol Phys. 2017;98(1):115-22. 33. Huddart R et al. Randomized phase II trial of adaptive image guided radiotherapy in muscle invasive bladder cancer: late toxicity and cancer outcomes. J Clin Oncol. 2023;41:446. 34. Huddart R et al. Clinical outcomes of a randomized trial of adaptive plan-of-the-day treatment in patients receiving ultrahypofractionated weekly radiation therapy for bladder cancer. Int J Radiat Oncol Biol Phys. 2021;110(2):412-24. 35. Jo YY et al. Optimized adaptive radiotherapy with individualized plan library for muscle-invasive bladder cancer using internal target volume generation. Cancers (Basel). 2022;14(19):4674. 36. Lutkenhaus LJ et al. Evaluation of delivered dose for a clinical daily adaptive plan selection strategy for bladder cancer radiotherapy. Radiother Oncol. 2015;116(1)51-6. 37. Murthy V et al. Adaptive radiotherapy for carcinoma of the urinary bladder: long-term outcomes with dose escalation. Clin Oncol (R Coll Radiol). 2019;31(9):646-52. 38. Murthy V et al. Clinical outcomes with dose-escalated adaptive radiation therapy for urinary bladder cancer: a prospective study. Int J Radiat Oncol Biol Phys. 2016;94(1):60-6. 39. Murthy V et al. ‘Plan of the day’ adaptive radiotherapy for bladder
Creative Commons Attribution-Non Commercial 4.0
●
40. Cox JD et al. Toxicity criteria of the Radiation Therapy Oncology Group (RTOG) and the European Organization for Research and Treatment of Cancer (EORTC). Int J Radiat Oncol Biol Phys. 1995;31(5):1341-6. 41. Nicholas S et al. Pelvic radiation and normal tissue toxicity. Semin Radiat Oncol. 2017;27(4):358-69. 42. Lawrie TA et al. Interventions to reduce acute and late adverse gastrointestinal effects of pelvic radiotherapy for primary pelvic cancers. Cochrane Database Syst Rev. 2018;1(1):CD012529. 43. Varian, a Siemens Healthineers Company. Conventionally fractionated adaptive radiation therapy of bladder cancer an individualized approach (ARTIAVesica). NCT05295992. https:// www.clinicaltrials.gov/study/ NCT05295992. 44. Varian. Daily online adaptive short-course radiation therapy and concurrent chemotherapy for muscle-invasive bladder cancer: a prospective trial of an individualized approach for reducing bowel and bladder toxicity (ARTIA-Bladder). NCT05700227. https://clinicaltrials. gov/study/NCT05700227. 45. University Health Network, Toronto. A study of adaptive radiation therapy for pelvic genitourinary cancer (ARTGU). NCT03909893. https:// clinicaltrials.gov/study/ NCT03909893. 46. Institute of Cancer Research, London. 3-dimensional conformal radiation therapy in treating patients with bladder cancer who have undergone transurethral resection of the bladder. NCT01124682. https://clinicaltrials. gov/study/NCT01124682. 47. Institute of Cancer Research. Study of weekly radiotherapy for bladder cancer (HYBRID). NCT01810757. https://clinicaltrials. gov/study/NCT01810757. 48. Royal Marsden NHS Foundation Trust. Adaptive planning in bladder cancer (APPLY). NCT01000129. https://clinicaltrials.gov/study/ NCT01000129. 49. Omar Mian. Adaptive radiation therapy with concurrent sacituzumab govitecan (SG) for muscle invasive bladder cancer. NCT05833867. https://clinicaltrials. gov/study/NCT05833867.
January 2024
●
Urology
13