Skip to main content

energystoreltd_TL A_casestudy_ballycastlesec

Page 1


Ballycastle Shared Education Campus

Ballycastle, NI

£70 million Shared Education Campus in Ballycastle. The cutting-edge educational facilities will be jointly used by Ballycastle High School and Cross and Passion College.

This exciting three-storey project will provide additional investment for high-quality sports facilities accessible to the community. While both schools will maintain their distinct identities within the new campus, the modern, purpose-built accommodation will enhance the shared delivery of the curriculum.

Project Details

"TLA was installed across all three floors of the Ballycastle SEC project - 200mm on the ground floor and 50mm on the upper floors - with excellent results. The system delivered clear programme benefits including by reducing the need for insulation storage on site, lowering labour requirements & significantly minimising waste This contributed to a more efficient, organised, and safer working environment throughout the build.

The team on site were well organised and coordinated seamlessly with our underfloor heating installer. They met every deadline for TLA, vapour barrier, and screed install. We will be considering energystore TLA for all future projects."

Cost effective

Reduced wastage

Thermal performance

Lightweight solution

Faster installation

Project Size 23000 m2
Main Contractor Heron Bros Ltd
Installer Alpha Flow Screeds
Product Grade TLA110 & TLA 250 Grades

Faster installation compared to traditional methods A2 Fire Rated Insulation Solution energystore TLA® combines eps beads coated in a specially formulated additive with cement and water to create a pourable insulation. This poured insulation offers an A2 fire rated alternative for use in floor and roof construction as a high strength void former or insulation.

Technical Characteristics

Cement Dosage (kg/m3)

Density after 28 days (kg/m3)

Thermal Conductivity (W/mK)

Compressive Strength (kPa)

Flexural Strength (N/mm2)

Permeability to Water Vapour (μ)

Shrinkage (NBN) (mm/m) Fire Reactivity

T&C’s:

No on-site TLA storage or waste.

<0.5% drying shrinkage.

No gaps or breaks in insulation layer that may cause performance issues.

High strength poured insulation

Suitable for flat and sloping roofs

Suitable to apply underfloor heating systems (UFH) directly on top

Suitable for ground bearing and suspended floors

Turn static files into dynamic content formats.

Create a flipbook
energystoreltd_TL A_casestudy_ballycastlesec by energystoreltd - Issuu