+ Because Safety Matters
Introducing Deta’s New
Circuit Protection Range
t: 01582 544 544 | e: sales.ce@deta.co.uk | w: deta.co.uk
1
+
10-YEAR GUARANTEE
Introducing Deta’s new and improved range of domestic circuit protection, a new stylish design providing home occupiers with maximum protection against potential dangers within the home. *
With a 10 year guarantee* the range covers enclosures incorporating Type 2 SPDs as standard along with a wide range of devices and accessories, providing a high quality and versatile solution for both new build homes and refurbishment projects.
*Unless otherwise stated.
2
t: 01582 544 544 | e: sales.ce@deta.co.uk | w: deta.co.uk
Contents
C
04
10
Protect+ Circuit Protection
Enclosure Configurations
06
11
Product Features
Technical Information
08
14
Product Selector
18th Edition Wiring Regulations BS7671:2018+A2:2022
t: 01582 544 544 | e: sales.ce@deta.co.uk | w: deta.co.uk
3
Circuit Protection Protect+ is a comprehensive range of enclosures, devices and accessories, providing maximum protection against short circuits, circuit overloads and residual earth leakage. Accessories including DIN rail mounted blanks and visor locks complete the range, ensuring safety by protecting live parts and restricting unauthorised access to circuits during the construction phase of a new build house.
+ Stylish & Versatile Designed with a pressed cover and visor, the stylish enclosures have a neutral white paint finish. Protect+ enclosures meet the requirements of the 18th Edition IET Wiring Regulations (BS 7671:2018 +A2:2022), being unobtrusive and blending into the décor of any modern home. Incorporating multiple knockout cable entry points, as well as clip in grommets, the enclosures minimise exposed cabling, providing a high quality and versatile solution for most domestic installations.
4
t: 01582 544 544 | e: sales.ce@deta.co.uk | w: deta.co.uk
Complete Solution Protect+ enclosures are easily configured and suitable for both new build homes and the upgrade/refurbishment of existing properties. All enclosures now come with a factory fitted Type 2 SPD to protect electronic equipment connected within the property from transient over voltages. Main Switch enclosures fitted with RCBOs and AFDDs on individual circuits provide superior protection, convenience and flexibility for occupants. High Integrity enclosures incorporating a 100A main switch plus 2 no 100A 30mA Type A RCDs provide a cost effective solution where budget dictates.
Surge Protection Surge Protection Devices (SPDs) redirect transient overvoltages, protecting valuable electronic devices and appliances from premature aging, damage or destruction. The SPD is factory fitted after the main switch and fed with a standard busbar with Neutral and Earth cables connected. Each device is rated at 100A and incorporates a visual indication window for normal operation or fault status. Taking up only one module, the SPD does not require a separate MCB for protection, relying on the upstream DNO fuse.
t: 01582 544 544 | e: sales.ce@deta.co.uk | w: deta.co.uk
5
Product Features Lockable Visor A lock can be installed on the hinged lid of the enclosure to prevent unauthorised access to circuits during construction. When building works are completed, the lock can be removed and replaced with a blanking cap.
Incoming Mains Tail Clamp A mains tail clamp is included as standard on all enclosures to provide additional restraint to the incoming tails.
Maximum Torque Settings Devices have cable strip lengths and recommended torque settings conveniently marked on the side of each device with torque settings also on the front of the device to aid installers doing an EICR or similar retro work.
Knockouts Round knockouts of varying sizes are positioned along the top and bottom of the enclosure as well as the sides with 32mm knockouts aligned with main switch position to aid installation of incoming tails. Large oval knockouts on the rear of the enclosure have clip in grommets to protect the cables.
6
t: 01582 544 544 | e: sales.ce@deta.co.uk | w: deta.co.uk
High Integrity enclosures supplied with 3 neutral bars Combi-head style terminal screws
Keyhole mounting slots
Taller enclosure provides generous wiring space
Floating busbar for greater installation flexibility
SPD factory fitted with earth & neutral cables
Raised removable DIN rail allows cables to pass underneath
Assembled with prewired switch, RCD’s and SPD
t: 01582 544 544 | e: sales.ce@deta.co.uk | w: deta.co.uk
7
Product Selector Protect+ Enclosures
10-YEAR EXTENDED GUARANTEE
Mains Switch Enclosures with 100A DP Isolator and Type 2 SPD PE1008S
8 Module, 5 Free Ways
PE1010S
10 Module, 7 Free Ways
PE1014S
14 Module, 11 Free Ways
PE1018S
18 Module, 15 Free Ways
PE1022S
22 Module, 19 Free Ways
Hi Integrity Enclosures with 100A DP Isolator, Type 2 SPD and 2 x 100A 30mA Type A RCDs PE3018S
18 Module, 11 Free Ways, 0+6+5/1+5+5/2+5+4
PE3022S
22 Module, 15 Free Ways, 0+8+7/1+7+7/2+7+6
PE3032S
32 Module, 25 Free Ways, 0+12+13/1+12+12/2+12+11
Garage Enclosure with 63A 30mA Type A RCD plus 1 x 32A and 1 x 6A MCB PE9010
4 Module IP2X
Shower Enclosure with 63A 30mA Type A RCD plus 1 x 50A MCB and 1 Blank PE9110
8
4 Module IP2X
t: 01582 544 544 | e: sales.ce@deta.co.uk | w: deta.co.uk
RCBOs
AFDD/RCBOs
5-YEAR EXTENDED GUARANTEE
6kA 30mA, 1+SwN, Type A
6kA 30mA, 1+SwN, Type A
B Curve
C Curve
B Curve
C Curve
PD4006
PD4106
6A
PD5006
PD5106
6A
PD4010
PD4110
10A
PD5010
PD5110
10A
PD4016
PD4116
16A
PD5016
PD5116
16A
PD4020
PD4120
20A
PD5020
PD5120
20A
25A
PD5032
PD5132
32A
PD5040
PD5140
40A
PD4025 PD4032
PD4132
32A
PD4040
PD4140
40A
MCBs
Accessories
6kA Single Pole B Curve
C Curve
PD6010
SPD Type 2 Kit (1 Mod SPD)
PD3006
PD3106
6A
PD9010
Blank Module (Din Rail Mounted)
PD3010
PD3110
10A
PD9901
Consumer Unit Visor Locking Kit
PD3016
PD3116
16A
PD9902
Oval Knockout Grommet
PD3020
PD3120
20A
PD9903
Label Sheet (Pack of 10)
PD3032
PD3132
32A
PD9904
MCB Lock (Pack of 5)
PD3040
PD3140
40A
PD9905
Meter Tail Clamp
PD3045
PD3145
45A
PD9906
Deta Branded Visor Blank (Pack of 10)
PD3050
PD3150
50A
PD9951
Off Peak Conversion Kit
PD3063
PD3163
63A
PD999009
9M Busbar (Pack of 5)
PD999021
21M Busbar
PD9910
14 Module Flush Mounting Frame
PD9911
18 Module Flush Mounting Frame
PD9912
22 Module Flush Mounting Frame
RCDs PD2063
63A 30mA, DP Type A
PD2080
80A 30mA, DP Type A
PD2010
100A 30mA, DP Type A
t: 01582 544 544 | e: sales.ce@deta.co.uk | w: deta.co.uk
9
Enclosure Configurations Mains Switch Enclosures Depending on the enclosure size chosen, allows from 5 up to a maximum of 19 independent cicruits to be connected. Intended for use with RCBOs and/or AFDD/RCBOs, each circuit is individually protected against both overload and earth leakage to prevent nuisance tripping originating from other circuits, providing the safest circuit protection solution. A 100A rated Type 2 SPD is factory fitted and utilises the standard busbar terminal connection as all other devices.
High Integrity Enclosures Depending on the enclosure size chosen a number of independent circuits can be accommodated after the Main Switch with remaining circuits protected by two 100A 30mA Type A RCDs and MCBs. Enclosures are easily configured by sliding RCDs along the DIN rail depending on installation requirements. A 100A rated Type 2 SPD is factory fitted and utilises the standard busbar terminal connection as all other devices. Independent circuits using RCBOs or AFDD/RCBOs lend themselves to safety critical (e.g. safety alarms) and high risk (e.g. EV Charge Points) circuits, avoiding nuisance tripping whilst maximising protection. Circuits protected by MCBs should be distributed across the two RCDs evenly with consideration given to circuit design. For example, downstairs and upstairs lighting circuits should be controlled by different RCDs to avoid a complete lighting outage if an earth leakage fault trips the connected RCD, cutting the supply to all the other connected circuits.
*
* Max independent devices using standard supplied busbar.
10
t: 01582 544 544 | e: sales.ce@deta.co.uk | w: deta.co.uk
Technical Information Consumer Units • 100A DP Main Switch • 100A rated Type 2 SPD • Steel enclosure with stylish curved visor • Round knockouts to four sides • Oval knockouts on rear of enclosure • 100A 30mA Type A RCD’s (High Integrity Enclosures) • Internal wiring 25mm2 tri rated cable
• Visor lockable with optional “visor locking kit” where required, e.g during construction. Note, best practice recommends that the visor should not be locked in normal residential use without separate provision to isolate the power in the event of an emergency • Supplied with circuit identification sheet, installation instructions, blank modules, busbar(s) and Deta logo • Complies: BS EN 61439-3 and BS 7671:2018+A2:2022
Knockout Positions
Enclosure Dimensions
t: 01582 544 544 | e: sales.ce@deta.co.uk | w: deta.co.uk
11
Technical Information RCDs A Residual Current Device constantly monitors the electric current flowing through one or more circuits that it is used to protect. If it detects an inbalance between the current in the Live and Neutral conductors, it trips automatically, protecting against the risk of electrocution and fire caused by residual currents. • • • • •
Protection against earth fault/leakage current and residual current Rated at 30mA for personal protection Contact position indicator 35mm DIN rail mounting Handle can be locked with lock out device and padlock to prevent unwanted operation for safety Type A
Current rating (In)
63A, 80A & 100A
Rated voltage (Un)
230/240Vac
Rated frequency
50Hz
Number of poles
Double pole
Residual current protection
Suitable for use on pure AC where pulsating DC residual currents up to 6mA exist
Rated tripping current
30mA
Rated short circuit
6kA
Mechanical endurance
10,000 cycles
Electrical endurance
2,000 cycles
Terminal capacity
25mm2
Terminal tightening torque
2.5 Nm
Standard
IEC/EN 61008-1
RCBOs A Residual Current Circuit Breaker with overcurrent protection provides protection against overcurrents (overload of the cable and short circuit) and earth leakage currents (which pose a risk to humans and animals or can result in fires). RCBOs will sense the fault and trip the circuit isolating both Live and Neutral conductors, ensuring complete protection of people, animals and connected equipment. • • • •
Provides protection against earth fault/leakage current, short circuit and overload Rated at 30mA for protection of humans and animals Single module width in compact format Provides protection to individual circuits offering the best technical solution within the household
•
Isolates both Live and Neutral conductors when tripped Type A RCD
12
Current rating (In)
6, 10, 16, 20, 25, 32, 40
Rated voltage (Un)
230/240Vac
Rated frequency
50Hz
Number of poles
1P + SwN
Residual current protection
Suitable for use on pure AC where pulsating DC residual currents up to 6mA exist
Rated tripping current
30mA
Magnetic tripping curve
B & C Curve
Breaking capacity (Icn = Ics)
6kA
Mechanical endurance
10,000 cycles
Electrical endurance
4,000 cycles
Terminal capacity
Top 10mm2 / Bottom 25mm2
Terminal tightening torque
1.2 Nm (load) / 2.5 Nm (line)
Standard
IEC/EN 61009-1
t: 01582 544 544 | e: sales.ce@deta.co.uk | w: deta.co.uk
MCBs Miniature Circuit Breakers protect domestic circuits against overloads and short circuits. B curve devices are traditionally more suited to domestic installations where switching surges are low or non existant and trip between 3 and 5 times full load current. C curve devices have become more relevant for some modern appliances/fittings where greater switching circuits may be present and will trip between 5 and 10 times full load current. • • •
Protection against overloads and short circuits Contact position indicator 35mm DIN rail mounting
•
Terminals have automatic blanking plate, preventing incorrect termination of busbar
Current rating (In)
6, 10, 16, 20, 32, 40, 45, 50, 63
Rated voltage (Un)
230/240Vac
Rated frequency
50Hz
Number of poles
Single pole
Magnetic tripping curve
B & C Curve
Breaking capacity (Icn)
6kA
Mechanical endurance
10,000 cycles
Electrical endurance
4,000 cycles
Terminal capacity
25mm2
Terminal tightening torque
2.5Nm (Line) / 2.5 Nm (Load)
Standard
IEC/EN 60898-1
AFDD/RCBOs Arc Fault Detection Devices integrated with an RCBO are the latest technology providing all the attributes afforded by an RCBO with added detection of dangerous serial and parallel arc faults that can develop within installations. Previously arc faults occurring as a result of damaged insulation/conductors or loose connections have not always been detected so can develop over time eventually resulting in a fire and damage to property and risk to people and animals. Current rating (In)
6, 10, 16, 20, 32, 40
Rated voltage (Un)
230/240Vac
Rated frequency
50Hz
Number of poles
1P + SwN
Residual current protection
Suitable for use on pure AC where pulsating DC residual currents up to 6mA exist
Magnetic tripping curve
B & C Curve
Breaking capacity (Icn)
6kA
Mechanical endurance
10,000 cycles
Electrical endurance
4,000 cycles
Terminal capacity
Top 10mm2 / Bottom 25mm2
Terminal tightening torque
1.2 Nm (Load) / 2.5 Nm (Line)
Standard
IEC/EN 60898-1 & BS EN 62606
t: 01582 544 544 | e: sales.ce@deta.co.uk | w: deta.co.uk
13
18th Edition Wiring Regulations BS 7671:2018+A2:2022
Surge Protection Devices Reg 443.4.1
Protection against transient over voltages shall be provided where the consequence caused by the over voltage could result in: •
Serious injury to, or loss of human life
•
Significant financial or data loss
For all other cases, SPDs shall be provided unless the owner of the installation declares it is not required due to any loss or damage being tolerable, and they accept the risk of damage to equipment and any consequential loss.
RCD & RCBO Selection Reg 531.3.2/3
UNWANTED TRIPPING Residual current protective devices shall be selected and erected such as to limit the risk of unwanted tripping. The following should be considered: (ii) The use of RCBOs for individual final circuits in residential premises. (iii) In order to avoid unwanted tripping by protective conductor currents and/or earth leakage currents, the accumulation of such currents downstream of the RCD shall not be more than 30% of the rated residual operating current.
RCD TYPE RCD type AC shall only be used to serve fixed equipment, where it is known that the load current contains no DC components.
NOTE: Examples of fixed equipment with a load current containing no DC components include but not limited to electric heating appliances, and/or simple filament lighting neither containing electronic components.
14
t: 01582 544 544 | e: sales.ce@deta.co.uk | w: deta.co.uk
Arc Fault Detection Devices Reg 421.1.7
Arc fault detection devices (AFDD) conforming to BS EN 62606 shall be provided for single-phase AC final circuits supplying socket-outlets with a rated current not exceeding 32A in: •
Higher Risk Residential Buildings (HRRB)
•
Houses in Multiple Occupation (HMO)
•
Purpose-built student accomodation
•
Care Homes
For all other premises, the use of AFDDs conforming to BS EN 62606 is recommended for single-phase AC final circuits supplying socket-outlets not exceeding 32A. Where used, AFDDs shall be placed at the origin of the circuit to be protected. The use of AFDDs does not obviate the need to apply one or more measures provided in other clauses in BS7671.
RCD Testing Reg 543.8
Previously, effectiveness under 643.7 and 643.8 was verified where the RCD disconnects within 40ms when tested at a current equal to or higher than five times its rated residual operating current. This has now been aligned with 643.7 and 643.8 and the new regulations are as follows: The verification of the effectiveness of the measures applied for additional protection is fulfilled by visual inspection and testing. Where RCDs are required for additional protection, the effectiveness of automatic disconnection of supply by RCDs shall be verified using suitable test equipment according to BS EN 61557-6 (see Regulations 643.1) to confirm that the relevant requirements of Chapter 41 are met. NOTE: Regardless of RCD Type, effectiveness is deemed to have been verified where an RCD disconnects within the time stated below with an alternating current tested at rated residual operating current (lΔn): •
For general non delay type, 300ms maximum
•
For delay ‘S’ type RCD, between 130ms minimum and 500ms maximum
RCD Protection Reg 411.3.3/4
Exceptions are now detailed requiring a risk assessment so certain socket circuits can be excluded, i.e. freezers, IT server rooms and control rooms. Outdoor lighting accessible by the public should have RCD protection. Reference is now made to where ‘ordinary persons’ having access to sockets, these shall be RCD protected. Where ‘competent/trained personnel’ are the only people accessing an area, i.e. control room, then RCDs can be omitted.
t: 01582 544 544 | e: sales.ce@deta.co.uk | w: deta.co.uk
15
Deta Electrical Company Limited Panattoni Park, Luton Road, Chalton Bedfordshire, LU4 9TT t: 01582 544 544 f: 01582 544 501 e: sales.ce@deta.co.uk w: deta.co.uk
09.23
16