2 N D F LO O R | O F F I C E T E S T F I T +/- 39,480 SF CAUTION: IF THIS PRINT IS NOT 30" X 42" THEN IT IS A REDUCED PRINT
TRYON ST
· ·
(151) 30" x 60" WORKSTATIONS (19) PRIVATE OFFICES
157 TOTAL HEADCOUNT E
RA
IL
203 HALLWAY
D EC
14'-6" x 22'±
LO W
W
A
LL
W
/
14'-6" x 22'±
D STE O P W N
O RA
TIV
209 PATIO
205 CONF.
204 CONF.
202 RECEPTION
5400 LBJ Freeway, Suite 125 Dallas, Texas 75240 P. 972.770.2222 | www.entosdesign.com
206 LOUNGE
36'-6" x 19'-6"± 255 COLLAB.
D STE O P W N
TRADE ST
254 OPEN OFFICE
208 LOUNGE
ISSUED FOR PRELIMINARY PURPOSES ONLY.
29' x 63'±
2
3
1
201 CORRIDOR 207 COFFEE
3
2
1
FEC
THESE DOCUMENTS MAY NOT BE USED FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION.
D STE O P W N
FEC
C
R D AM O P W N
RE
211 OFFICE
18' x 15'± 255 WELLNESS
C
FE
251 WOMEN
E
247 HEADS DN. 246 HEADS DN.
245 HEADS DN. 244 HEADS DN.
7'-6" x 6'±
259 HALLWAY
236 OFFICE
7'-6" x 6'±
250 MEN
263 BOOTHS FEC
261 COFFEE
235 HALL
237 OFFICE
266 PANTRY
260 WELLNESS
258 SEATING
9'-6" x 13'±
212 OFFICE
14' x 15'±
9'-6" x 13'±
213 OFFICE
238 OFFICE
7'-6" x 6'±
14' x 15'±
262 SEATING
9'-6" x 13'±
LEGEND
2,442 SF±
234 OFFICE
9'-6" x 13'±
7'-6" x 6'±
N E D WS O T W EP N
H
5"
7.
C
C
N
O
C
T RE
Approved: _________________________ Date: ___________
DN
252 PRINT
433 SF±
248 HEADS DN.
UP
257 COLLAB.
249 IT EQUIP
B
267 MEN
200 ELEVATOR LOBBY
7.
UR
GENERAL
20' x 15'±
0000 OFFICE
264 SEATING
9'-6" x 13'± 232 OFFICE
243 PHONE
(ALL SYMBOLS MAY NOT APPLY)
214 OFFICE
233 OFFICE
7'-6" x 6'±
9'-6" x 13'±
FE
14' x 15'±
230 OFFICE
9'-6" x 15'±
227 CONF.
242 OPEN OFFICE
C
FE
228 OFFICE
PARTITION WITH SOUND INSULATION
FIRE EXTINGUISHER W/ CABINET
HALF HEIGHT WALL ONE HOUR PARTITION W/ SOUND INSULATION
FIRE EXTINGUISHER ON HOOK
CODE INFORMATION
226 CONF.
CODE COMPLIANCE
BUILDING FIRE SAFETY MECHANICAL PLUMBING ELECTRICAL ENERGY ACCESSIBILITY
216 CONF.
8' x 7'± R D AM O P W N
27' x 15'±
240 OFFICE
10' x 14'± C
FE
241 OFFICE
217 OFFICE
OTHER
21'-6" x 20'±
10' x 14'±
- NORTH CAROLINA STATE BUILDING CODE - NORTH CAROLINA STATE FIRE CODE - NORTH CAROLINA STATE MECHANICAL CODE - NORTH CAROLINA STATE PLUMBING CODE - NORTH CAROLINA STATE ELECTRICAL CODE - NORTH CAROLINA STATE ENERGY CODE - NORTH CAROLINA STATE BUILDING CODE (CH. 11) & ANSI A117.1
FULLY FIRE SPRINKLERED OCCUPANCY GROUP
- YES - BUSINESS
OCCUPANCY LOAD SUMMARY - Suite 200
224 OFFICE
10' x 14'±
LOAD FACTOR
AREA (S.F.)
# OF OCCUPANTS
BUSINESS AREAS
100 GROSS
30019
301
ASSEMBLY UNCONCENTRATED
15 NET
1358
91
47
11
31377
392
FUNCTION OF SPACE
223 OFFICE
10' x 14'± 218 OPEN OFFICE
ASSEMBLY - FIXED SEATS
1:24"
TOTAL
222 COPY
13' x 14'±
EGRESS
100' 74' 2 6 286' 95' 227' 50' 36'
219 OPEN OFFICE RAMP DOWN
DEMISING PARTITION W/ SOUND INSULATION
NEW PARTITION
SIDELIGHT/WINDOW
225 HEADS DN.
PM: KC 1.0: SEL 2.0: SEL 2.1: SEL
PHONE BOARD
TWO HOUR PARTITION W/ SOUND INSULATION
14' x 22'±
FEC
EXISTING PARTITION
265 BREAK
9'-6" x 15'±
9'-6" x 15'±
8' x 7'±
FE
W
229 OFFICE
239 HEADS DN.
FEC
M
14' x 22'±
ROOM NUMBER ROOM NAME
WATER LINE WITH SHUT-OFF VALVE
215 OFFICE
M
C
W
231 COLLAB.
221 COLLAB.
These drawings are assumed to be complete and final. It shall be the tenant/client's responsibility to review and bring in writing any design discrepancies to the designers' attention. Any design changes will be at additional expense. The designer shall not be held responsible for city, state and federal code/regulation authority's interpretations.
C
C
R D AM O P W N
C
H 5"
210 CONF.
16' x 23'±
C
N
DN
B UR
TE
O
UP
FE
256 WOMEN
FE
253 IT LAB
13' x 17'±
COMMON PATH OF EGRESS TRAVEL (MAX. ALLOWED) COMMON PATH OF EGRESS TRAVEL (ACTUAL) EXITS (MIN. REQUIRED) EXITS (ACTUAL) LONGEST DIAGONAL EXIT SEPARATION (MIN. REQUIRED) EXIT SEPARATION (ACTUAL) DEAD END (MAX. ALLOWED) DEAD END (ACTUAL)
FLOOR INFORMATION
DN UP
BUSINESS SQUARE FOOTAGE
33832
BUSINESS OCCUPANCY
392
FLOOR REQUIREMENTS MEN'S RESTROOM
CURRENT
REQUIRED
PROPOSED
LAVATORIES
3
4
5
WATER CLOSETS
3
5
6
CURRENT
REQUIRED
PROPOSED
WOMEN'S RESTROOM LAVATORIES
3
4
5
WATER CLOSETS
4
5
6
CURRENT
REQUIRED
PROPOSED
2
4
4
DRINKING FOUNTAIN
01 Preliminary Plan Scale: 1/8" = 1'-0"
0
2'
4'
8'
SCALE:1/8" = 1' - 0"
16' TRUE NORTH
PLAN NORTH
For Review
10/01/2024
2.1
For Review
09/30/2024
2.0
For Review
09/20/2024
1.0
For Review
09/20/2024
No.
Issued
Date
Project Rise
One Independence Center
PLUMBING FIXTURE COUNTS
220 COLLAB.
2.2
ROOM SIZES ARE APPROXIMATE ONLY AND ARE NOT TO BE USED FOR FINAL DETERMINATION OF FURNITURE SIZES OR PLACEMENT.
101 N. Tryon St. 2nd Floor Charlotte, NC 28202
39,480 RSF Project ID: 22-1088-L028 Sheet Title
Preliminary Plan
2.2
Sheet Number