the brook.
811 WEST FULTON STREET CHICAGO, ILLINOIS 60607
EXISTING USE GROUP
CLASSIFICATION OF ENTIRE BUILDING: B
EXISTING CONSTRUCTION
CLASSIFICATION: TYPE 1A, SPRINKLERED
PROJECT CLASSIFICATION:
USE GROUP CLASSIFICATION: B
PROJECT OCCUPANCY:
ASSEMBLY AREAS: BUSINESS AREA
BUSINESS AREA: 150 GROSS
LEVEL 6 SF: 10,060/150 GROSS = 68 OCCUPANTS LEVEL 6 + LEVEL 7 = 68 + 68 = 136 TOTAL OCCUPANTS
1. ALL WORK IS TO BE DONE IN ACCORDANCE WITH THE RULES AND REGULATIONS OF THE LOCAL JURISDICTION. UNLESS OTHERWISE AGREED UPON, THE GENERAL CONTRACTOR IS RESPONSIBLE FOR SECURING ALL BUILDING PERMITS AS REQUIRED FOR WORK HE IS TO PERFORM AND WILL RETAIN AND PAY FOR ALL REQUIRED INSPECTIONS DURING THE COURSE OF THE WORK.
2. ANY DISCREPANCIES FOUND IN THE PLANS, DIMENSIONS, EXISTING CONDITIONS, CONSULTANT DRAWINGS, OR ANY APPARENT ERROR IN CLASSIFYING OR SPECIFYING A PRODUCT OR ITS USE IS TO BE POINTED OUT TO THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. ADDENDA WILL BE ISSUED AS NECESSARY AND WILL BECOME PART OF THE CONTRACT DOCUMENTS. FOR THOSE DISCREPANCIES NOT BROUGHT TO THE ATTENTION OF THE ARCHITECT, IT WILL BE ASSUMED THAT THE CONTRACTOR HAS BID THE MORE EXPENSIVE METHOD OF CONSTRUCTION.
3. ANY DAMAGE TO NEW OR EXISTING CONSTRUCTION CAUSED BY THE CONTRACTOR'S NEGLIGENCE OR INADEQUATE PROTECTIVE OR SECURITY MESASURES DURING CONSTRUCTION ARE TO BE CORRECTED AT HIS EXPENSE.
4. THE CONTRACTOR FOR A PERIOD OF ONE YEAR FROM THE DATE OF COMPLETION AND ACCEPTANCE BY TENANT, SHALL ADJUST, REPAIR, OR REPLACE AT NO COST TO THE TENANT ANY ITEM OF EQUIPMENT, MATERIAL, OR WORKMANSHIP FOUND TO BE DEFECTIVE, INCLUDING OR AFFECTED WITHIN THE SCOPE OF THE CONTRACT.
5. DRAWINGS ARE NOT TO BE SCALED FOR DIMENSIONS AND OR SIZES. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD MEASURING EXISTING CONDITIONS PRIOR TO BEGINNING OF WORK AND PERIODICALLY DURING PROGRESS OF WORK TO VERIFY ALL CRITICAL DIMENSIONS. ANY DEVIATIONS FROM DIMENSIONS INDICATED ON DRAWINGS IS TO BE APPROVED BY ARCHITECT, PRIOR TO CONSTRUCTION.
6. SHOP DRAWINGS ARE TO BE SUBMITTED TO THE ARCHITECT FOR APPROVAL BEFORE PROCEEDING WITH ALL ITEMS THAT REQUIRE FABRICATION.
7. GENERAL CONTRACTOR TO NOTIFY ARCHITECT FOR REVIEW OF PARTITION CHAULK LINE LAYOUT.
8. GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS AS SHOWN IN FIELD AND NOTIFY ARCHITECT OF ANY DISCREPANCIES.
ABBREVIATIONS LIST
@ AT A.B. ANCHOR BOLT
AHU AIR HANDLER UNIT
APRX APPROXIMATE
BD BOARD
BLDG. BUILDING
BOH BACK OF HOUSE
B.O. BOTTOM OF
B.O.S. BOTTOM OF SLAB
B.O.B. BOTTOM OF BEAM
CAB CABINET
CLR CLEAR
COL COLUMN
CONC CONCRETE
DTL DETAIL
DIA DIAMETER
DWG DRAWING
EA EACH
EL. ELEVATION
EQ EQUAL
F.F. FINISH FLOOR
F.V. FIELD VERIFY
FACP FIRE ALARM CONTROL PANEL
F.D. FLOOR DRAIN
FOH FRONT OF HOUSE
FRP FIBERGLASS REINFORCED PLASTIC
GA GAUGE
GYP GYPSUM
HDW HARDWARE
HOR. HORIZONTAL
JT. JOINT
LF LINEAR FEET
MAX MAXIMUM
MECH MECHANICAL
MTL METAL
MIN MINIMUM
N/A NOT APPLICABLE
N.I.C. NOT IN CONTRACT
N.F.C. NOT FOR CONSTRUCTION
N.T.S. NOT TO SCALE
#/NO. NUMBER
O.C. ON CENTER
O.D. OUTSIDE DIMENSION
RM ROOM
REQD REQUIRED
R.O. ROUGH OPENING
SF SQUARE FOOT
SIM SIMILAR
SPEC SPECIFICATION
STL STEEL
SUSP SUSPEND
T.O. TOP OF
T.O.B. TOP OF BEAM
T.O.S. TOP OF SLAB
TYP TYPICAL
VERT. VERTICAL
VIF VERIFY IN FIELD
W/ WITH
MAP
ACCESSIBLE ROUTES COMMUNICATION ELEMENTS
1. THE EXTENT OF THE DEMOLITION IS GENERALLY DESCRIBED. THE CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION WORK REQUIRED TO ACCOMODATE THE INSTALLATION OF THE PROPOSED WORK.
2. THESE DOCUMENTS HAVE BEEN PREPARED BASED UPON VISIBLE CONDITIONS AVAILABLE FOR INSPECTION AND OWNER'S RECORD DOCUMENTS. CERTAIN AREAS AND PORTIONS OF THE WORK MAY VARY FROM CONDITIONS INDICATED HEREIN WHEN UNCOVERED AT THE SITE. EACH CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND PROMPTLY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES BETWEEN THESE DOCUMENTS AND THE EXISTING CONDITIONS.
3. VERIFY ALL EXISTING DOMENSIONS AND CONDITIONS PRIOR TO INITIATING WORK. COORDINATE LIMITS OF DEMOLITION WORK WITH REQUIREMENTS OF NEW WORK.
1. THE EXTENT OF THE DEMOLITION IS GENERALLY DESCRIBED. THE CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION WORK REQUIRED TO ACCOMODATE THE INSTALLATION OF THE PROPOSED WORK.
2. THESE DOCUMENTS HAVE BEEN PREPARED BASED UPON VISIBLE CONDITIONS AVAILABLE FOR INSPECTION AND OWNER'S RECORD DOCUMENTS. CERTAIN AREAS AND PORTIONS OF THE WORK MAY VARY FROM CONDITIONS INDICATED HEREIN WHEN UNCOVERED AT THE SITE. EACH CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND PROMPTLY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES BETWEEN THESE DOCUMENTS AND THE EXISTING CONDITIONS.
3. VERIFY ALL EXISTING DOMENSIONS AND CONDITIONS PRIOR TO INITIATING WORK. COORDINATE LIMITS OF DEMOLITION WORK WITH REQUIREMENTS OF NEW WORK.
4' x 8' PERFORATED ACOUSTICAL WOOD PANELS
9' 0" A.F.F
2' x 4' TROLDTEKT
PANELS 9' - 0" A.F.F
2' x 4' TROLDTEKT
PANELS 9' - 0" A.F.F
2' x 4' TROLDTEKT
ACOUSTIC PANELS
9' - 0" A.F.F
- 0" A.F.F
PANELS
2' x 4' TROLDTEKT ACOUSTIC PANELS
9' - 0" A.F.F
GYP. WALLBOARD
DEGLAS ACRYLIC PANELS
TROLDTEKT ACOUSTIC PANELS
ACOUSTICAL WOOD PANELS
LUMINART CONE SUSPENSION/CEILING
LOUIS PAULSEN ABOVE PENDANT
LOUIS PAULSEN KEGLAN PENDANT
8" INCANDESCENT DOWNLIGHTRECESSED CAN
XAL BO 55 INTRACK 2 LAMPS
LUMINART OFFSET SUSPENSION
2' x 4' TROLDTEKT ACOUSTIC PANELS 9' - 0" A.F.F
2' x 4' TROLDTEKT
ACOUSTIC PANELS
9' - 0" A.F.F
2' x 4' TROLDTEKT ACOUSTIC PANELS 8' - 0" A.F.F
2' x 4' TROLDTEKT ACOUSTIC PANELS
9' - 0" A.F.F
4' x 8' PERFORATED ACOUSTICAL WOOD PANELS
9' - 0" A.F.F
4' x 8' PERFORATED ACOUSTICAL WOOD PANELS
9' - 0" A.F.F
EXPOSED TO CEILING STRUCTURE
10' - 3" A.F.F
4' x 8' PERFORATED ACOUSTICAL WOOD PANELS
EXPOSED TO SKYLIGHT STRUCTURE
HIGH IMPACT ACRYLIC PANELS
10' - 3" A.F.F
2' x 4' TROLDTEKT ACOUSTIC PANELS
9' - 0" A.F.F
2' x 4' TROLDTEKT
ACOUSTIC PANELS
9' - 0" A.F.F
2' x 4' TROLDTEKT ACOUSTIC PANELS
2' x 4' TROLDTEKT ACOUSTIC PANELS
9' 0" A.F.F
9' - 0" A.F.F
2' x 4' TROLDTEKT
ACOUSTIC PANELS
9' - 0" A.F.F
GWB ON MTL. STUD 8' - 0" A.F.F GWB ON MTL. STUD
- 0" A.F.F GWB ON MTL. STUD
- 0" A.F.F GWB ON MTL. STUD 8' - 0" A.F.F
2' x 4' TROLDTEKT ACOUSTIC PANELS
9' 0" A.F.F
2' x 4' TROLDTEKT ACOUSTIC PANELS
9' - 0" A.F.F
GYP. WALLBOARD
DEGLAS ACRYLIC PANELS
TROLDTEKT ACOUSTIC PANELS
ACOUSTICAL WOOD PANELS
LUMINART CONE SUSPENSION/CEILING
LOUIS PAULSEN ABOVE PENDANT
LOUIS PAULSEN KEGLAN PENDANT
8" INCANDESCENT DOWNLIGHTRECESSED CAN
XAL BO 55 INTRACK 2 LAMPS
LUMINART OFFSET SUSPENSION
LUMINART POP PETIT SUSPENSION LIGHT
EXISTING CONCRETE CEILING STRUCTURE
CONT. RUNNER TRACK. ATTACH TO EXIST. STRUCTURE 1" ROLLER HOOKS
FINISHES FINISH SCHEDULE
MOSSY/FLORAL INSTALLATION
WD-1 5" x 10'3" RECLAIMED HEART PINE PANELING, 1/2" SQUARED EDGE, SQUARE MILL PROFILE COLOR: SANDED SMOOTH, UNFINISHED MANUFACTURER: ELMWOOD RECLAIMED TIMBER CONTACT: 1-800-705-0705
WD-2 1/4" x 4' x 8' PUREBOND BIRCH PLYWOOD PANELS COLOR: SKY BLUE PAINT WASH FINISH, SANDED MANUFACTURER: HOME DEPOT CONTACT: 1-800-466-3337
COLOR:
MANUFACTURER: DEGLAS ACRYLIC BUILDING PRODUCTS CONTACT: 905-774-7427
CK-1 ROCK CORK WALL SHEET COLOR: NATURAL, UNFINISHED MANUFACTURER: AMCORK CONTACT: 1-888-955-2675
T-1 PORTMORE SKY BLUE 4" x 4" GLOSSY CERAMIC TILE COLOR: SKY
MANUFACTURER: TILEBAR CONTACT: 888-541-3840
SC 2' x 4' TROLDTEKT NATURAL WOOD ACCOUSTIC PANELS COLOR: NATURAL WOOD MANUFACTURER: TROLDTEKT BY KINGSPAN CONTACT: 45-8747-8100
2' x 4' TROLDTEKT ACOUSTIC PANELS
- 0" A.F.F
- 0" A.F.F EXPOSED TO CEILING STRUCTURE
HIGH IMPACT ACRYLIC PANELS 10' - 3" A.F.F EXPOSED TO SKYLIGHT STRUCTURE 2'
2' x 4' TROLDTEKT ACOUSTIC PANELS 9' - 0" A.F.F 2' x 4' TROLDTEKT ACOUSTIC PANELS
2' x 4' TROLDTEKT ACOUSTIC PANELS