INTERIOR RENO STAR LGHT

Page 1

678-525-2829 jennyaburger @gmail.com

JENNY BURGER

COMPUTER DRAWING TECHNICIAN

DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION

• International Building Code, 2012 Edition, with Georgia Amendments (2015) • International Residential Code, 2012 Edition, with Georgia Amendments (2015) • International Fire Code, 2012 Edition, with Georgia Amendments (2013) • International Plumbing Code, 2012 Edition, with Georgia Amendments (2015) • International Mechanical Code, 2012 Edition, with Georgia Amendments (2012) • International Fuel Gas Code, 2012 Edition, with Georgia Amendments (2015) • National Electrical Code, 2014 Edition, with no Georgia Amendments • International Energy Conservation Code, 20011 Edition, with Georgia Supplements and Amendments (2011) (2012) • 2012 NFPA 101 – Life Safety Code with state Amendments (2013)

Layout Page Table Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

Description TITLE SHEET EXISTING FLOOR PLAN MAIN LEVEL EXISTING BASEMENT FLOOR PLAN-RED LINES MAIN LEVEL EXISTING FLOOR PLAN LOWER BASEMENT LEVEL EXISTING ELEVATION 1 & 2 FRONT & LEFT SIDE EXISTING ELEVATIONS 3 & 4, REAR AND RIGHT SIDE EXISTING ROOF PLAN DEMOLITION PLAN MAIN LEVEL PROPOSED FLOOR PLAN MAIN LEVEL PROPOSED FLOOR PLAN LOWER BASEMENT LEVEL HOUSE CROSS SECTION & DETAILS PROPOSED ROOF AND ROOF FRAMING PLANS FLOOR FRAMING PLAN & CEILING FRAMING PLAN PROPOSED BASEMENTFLPL-RED LINES MAIN LEVEL PROPOSED ELEVATION 1 PROPOSED ELEVATIONS 2 LEFT SIDE & 4 RIGHT SIDE PROPOSED ELEVATION 3 REAR DOORS/WINDOWS LOWER BASEMENT LEVEL DOOR/WINDOWS MAIN LEVEL LIGHTING ELECTRICAL PLAN MAIN LEVEL LIGHTING ELECTRICAL PLAN BASEMENT LEVEL

DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION

Effective January 1, 2014 The following will be the State of Georgia's minimum Standard Construction Codes:

RELEASED FOR CONSTRUCTION

NO CHANGES TO THE FOOT PRINT. A LOAD BEARING INTERIOR WALL WILL BE REMOVED AND AN LVL RECESSED INTO THE CEILING WILL BE INSTALLED.

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

1/23/2018

TITLE SHEET SCALE: 1/4" = 1' - 0"

SHEET: 1 OF 21


678-525-2829 jennyaburger @gmail.com

JENNY BURGER

COMPUTER DRAWING TECHNICIAN

E3

39'

10'-8"

18'-4 5/8"

20'-2 7/8"

6'-10 7/8"

17'-11"

79'-3"

3046DH

3046DH

5'

8 3/8"

3946FX

MASTER BDRM

2'-9"

FLOORING TILE

247 SQ FT

187 SQ FT FLOORING TILE

DN OPEN BELOW 23 SQ FT

LOAD BEARING WALL

18'-0 7/8"

2668

21'-8 7/8" 3'-6"

3046DH

15'-3 5/8"

3'-1"

2668

2668

HALL 13 SQ FT

1'-3 7/8"

7'-4 7/8"

7'-5 5/8" CLOSET

2'-8"

12 SQ FT

3'-4"

2668

10'-1"

42'-11"

3'-11 1/2"

HALL 87 SQ FT

7'

10 SQ FT

51068

2868

3068

LIVING ROOM

15'-3 5/8" 12'-7"

17'-4"

BEDROOM 143 SQ FT

BEDROOM

9'-1"

8 3/8"

8 3/8"

41 SQ FT

12'-7"

ENTRY

13'-7 1/2"

4068

7'-2 1/2"

236 SQ FT

130 SQ FT

3068 3046DH

PORCH

4'

28 SQ FT

EXISTING CONCRETE DRIVEWAY

8 3/8"

5046FX

3'-10 3/4"

3046DH

3'-6 5/8"

3046DH 3046DH

CLNG HGHT: 89"

8 3/8"

IRON RAILING

1'-11" 8 1/2"

3'

2"

3'

2'

3'-5"

3'

2"

5'

EXISTING SIDE WALK

10'-1"

4 1/2"

18'-0 7/8" LIVING AREA 1809 SQ FT

2"

7' 3'

3'-3 7/8" 4 1/2"

3046DH 3046DH 2'-5 1/2"

8 1/2" 6'-4 1/2"

6"

5 SQ FT

6 SQ FT

4'-9" CLOSET

18 SQ FT

3'

CLOSET

2'-6 1/4"

2'-1 3/4"

CLOSET

2'-5 3/4"

CLOSET

2668

3046DH

DINING 132 SQ FT

2'-1 1/4"

2668

1'-0 1/2"

6168

4'-2 3/4"

2'-11"

2068

2068

11'-0 2" 1/2" 3' 3' 11'-0 1/2"

3046DH 3046DH 2'-5" 4 1/2"

2'-6"

3'

11'-1" 2" 11'-1"

3'

32'-10 1/2"

12'-1 1/4"

WATER

2'-4 1/8" 4 1/2" 1'-7 7/8" 4 1/2"

8'-7 3/4"

FLOORING TILE

E4

DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION

3032DH

BATH

8 1/2"

RELEASED FOR CONSTRUCTION

5"

2068

13'-1"

360 SQ FT

3'

MASTER BATH

59 SQ FT

19'-6 5/8"

CAR PORT

8'-4 5/8"

TOILET

FAMILY ROOM

25'-6 3/4"

7'-7 1/8"

12'-1 1/4"

2 5/8"

3'-9"

1'-3" 4 1/2"

4 1/2"

10'-8"

3'-10"

180 SQ FT

13'-1"

8'-9"

8 1/2"

3'

KITCHEN

7'-6"

26'-11 7/8"

3'-10"

3'

37 SQ FT

9 1/8"

E2

19'-4 1/8"

TUB SHOWER

WATER

8'-3 5/8" 4'-8 3/4"

UP

8 1/2"

CLNG HGHT: 117" FLOORING: TILE

3032DH

1'-1"

3' 1'-11 1/2"

5 1/2" 6"

3'

19'-9 1/2"

3046DH

5'-4"

7 7/8"1'-1"

3'

8 1/2"

15'-3 5/8"

4 1/2"

12'-2" 13'-6"

2668

6'-8"

3031DH

71 SQ FT

1'-1" 2'-9 7/8"

3'

6'-1"

1'-10" 3'

9'-10"

1'-10"

6'-8" 8 1/2"

3068

LAUNDRY

3068

32'-10 1/2"

Elevation 2

8 3/8"

2832DH 2832DH

8 1/2" 1'-5"

5'-4"

4 1/2"

4'-1 3/8"

8'-7 1/4" 14'-1 5/8" 12'-1 1/4"

DECK 177 SQ FT

EXISTING FLOOR PLAN-MAIN LEVEL 2X4 STUDS INTERIOR DIMENSIONS ARE FROM DRYWALL TO DRYWALL CEILING HEIGHT: 94.75" MAIN FLOORING: HARDWOOD

1'-3" 8 1/2"

3'

8 5/8"

3'

3'-8 7/8"

6'-10 7/8"

6"

3'-0 5/8"

2'-8"

4 1/2"

5'-6"

3'-10" 1'-8"

2"

8 3/8"

5'-4 1/8"

1'-4"

2'-8"

8 1/2"

8 3/8" 11 5/8" 8 3/8"

9'-10"

7'-11 7/8"

1'-8"

4 1/2"

18'-4 5/8"

8 3/8" 11 5/8" 8 3/8"

4 1/2"

10'-8"

9'-11"

8 1/2"

2'-5" 8 1/2"

59'-10 7/8"

E1

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

1/23/2018

EXISTING FLOOR PLAN MAIN LEVEL SCALE: 1/4" = 1' - 0"

SHEET: 2 OF 21


678-525-2829 jennyaburger @gmail.com

JENNY BURGER

COMPUTER DRAWING TECHNICIAN

EP

4X15.5 POST

8X15.5 POST

WH

4X15.5 POST

RELEASED FOR CONSTRUCTION

E3

E2

8X15.5 POST

E4

4X15.5 POST

4X15.5 POST

4X15.5 POST

E1

DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION

8X15.5 POST

UP

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

1/23/2018

EXISTING BASEMENT FLOOR PLAN-RED LINES MAIN LEVEL SCALE: 1/4" = 1' - 0"

SHEET: 3 OF 21


678-525-2829 jennyaburger @gmail.com

JENNY BURGER

COMPUTER DRAWING TECHNICIAN

E3

EXISTING FLOOR PLAN-LOWER LEVEL BASEMENT 2X4 STUDS INTERIOR DIMENSIONS ARE FROM DRYWALL TO DRYWALL CEILING HEIGHT: 97" FLOOR JOIST ABOVE: 9.25" MAIN FLOORING: CARPET AND TILE 8"

7'-5 3/8"

8"

18'-5 7/8"

8"

5'-5"

8"

4 1/2"

22'-7 1/2"

6'-8"

4 1/2"

RELEASED FOR CONSTRUCTION

9'-0 3/4"

79'-3" 3'-3 1/2" 8"

1'

3046DH

TUB SHOWER

E2

625 SQ FT

3'-1" 4 1/2"

E4

2668 CRAWL SPACE

UNFINISHED

18'-9"

12'-4"

8X15.5 POST

32 SQ FT

7'-9"

2068 7'-5"

17'-2 1/8"

8"

18'-9"

4 1/2" 2'-1 7/8" 4 1/2"

SOFFIT

33 SQ FT VALVE ACCESS

8"

4 1/2"

6'-8 1/2"

4 1/2" 5'-3 1/2"

8"

2'-2"

STEEL POST

8"

1'-1 1/2"

2'-2 3/8"

CLOSET

4'-6"

BAR

4X15.5 POST

4'-6"

4X15.5 POST

8"

4X15.5 POST

6'-5"

WINDOW BOX SEAT

9'-4"

36'-11"

6'-5"

1'-0 1/2"

4 1/2"

13'-1"

CONCRETE GARAGE FLOOR ABOVE

3032DH 3032DH

DROPPED GRID CEILING CARPET

7'-2"

312 SQ FT

32'-10 1/2"

3'-9"

FAMILY ROOM 28'

18'-1 3/4"

13'-11" 5'-8"

STEEL POST

9'-1"

UP

25 SQ FT

7'-5"

STEEL POST

8'-4"

1'

28'-4"

LOAD BEARING POST

8X15.5 POST

25'-4 5/8"

STAIRS STEEL POST

2'-9"

14 SQ FT

13 STEPS 9'-10"

8 1/2"

UNSPECIFIED

7'-11"

2'-10 5/8"

48 SQ FT

4 1/2"

1'-6"

SOFFIT

CONFIRMX68

BATH

18'-4"

2'-8"

7'-11"

8'-3 5/8"

6'-7 1/2"

7'-0 1/2"

6'-5"

748 SQ FT

15'-11"

8"

8'-7"

KEEP AND REUSE WATER HEATER

UNFINISHED

32'-10 1/2"

Elevation 2

WH

3968

50 SQ FT

8X15.5 POST

5'-2 3/8"

CRAWL SPACE

59 SQ FT

3'-10 1/2"

WINDOW BOX SEAT

5'-1"

PLUMBING PIPE

32'-2"

CRAWL SPACE

8"

4X15.5 POST

4X15.5 POST

2668

3'-2"

5'-3"

3'-10"

4X15.5 POST

1'-8"

2'-2"

EP

3046DH 3046DH

3032DH

8"

1'

3068

8"

3046DH

8"

8"

3.5X5.5 POST

8"

29'-6 1/2"

8"

79'-3" LIVING AREA 1626 SQ FT

E1

DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION

2'-2"

3.5X5.5 POST

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

1/23/2018

EXISTING FLOOR PLAN LOWER BASEMENT LEVEL SCALE: 1/4" = 1' - 0"

SHEET: 4 OF 21


678-525-2829 jennyaburger @gmail.com

JENNY BURGER

COMPUTER DRAWING TECHNICIAN

EXISTING ELEVATION 1 FRONT

4 : 12

5046FX

3046DH

3046DH 3046DH

3046DH 3046DH

3068

GRADE

GRADE

RELEASED FOR CONSTRUCTION

3068

3046DH

8'-4"

9'-4"

9'-11"

3046DH 3046DH

WROUGHT IRON COLUMN

4 : 12

EXISTING ELEVATION 2 LEFT SIDE 10819VT

16'-9"

3'

7'-5"

3946FX

2X8 JOIST

8'-10"

8'-3"

GRADE

ST A

U I RS

DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION

3031DH

WROUGHT IRON COLUMN

4 : 12

P THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.

GRADE

SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

1/23/2018

EXISTING ELEVATION 1 & 2 FRONT & LEFT SIDE SCALE: 1/4" = 1' - 0"

SHEET: 5 OF 21


678-525-2829 jennyaburger @gmail.com

JENNY BURGER

COMPUTER DRAWING TECHNICIAN

EXISTING ELEVATION 3 REAR

4 : 12

3032DH

3046DH

2832DH 2832DH 3046DH

RELEASED FOR CONSTRUCTION

3032DH 3046DH

3068

3032DH 3046DH

3046DH 3068

DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION

EXISTING ELEVATION 4 RIGHT SIDE

4 : 12

3046DH

3046DH

16'-9"

3046DH 3046DH

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.

3032DH 3032DH CONFIRMX68

SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

1/23/2018

EXISTING ELEVATIONS 3 & 4, REAR AND RIGHT SIDE SCALE: 1/4" = 1' - 0"

SHEET: 6 OF 21


678-525-2829 jennyaburger @gmail.com

JENNY BURGER

4 : 12

RELEASED FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

4 : 12

4 : 12

4 : 12

DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION

4 : 12

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

1/23/2018

EXISTING ROOF PLAN SCALE: 1/4" = 1' - 0"

SHEET: 7 OF 21


678-525-2829 jennyaburger @gmail.com

JENNY BURGER

COMPUTER DRAWING TECHNICIAN

RELEASED FOR CONSTRUCTION

DEMOLITION PLAN

CONFIRM THIS WINDOW HEIGHT BEFORE ORDERING.

DW

PROPOSED FLOOR PLAN-MAIN LEVEL 2X4 STUDS INTERIOR DIMENSIONS ARE FROM DRYWALL TO DRYWALL CEILING HEIGHT: 94.75" MAIN FLOORING: LAMINATE WOOD FLOOR, CARPET IN BEDROOMS, CONFIRM BATH FLOORING.

MICROWAVE VENT

TUB SHOWER

WASHER DRYER

WATER

FLOORING TILE

ELECTRIC RANGE MICROWAVE VENT

CLNG HGHT: 117" FLOORING: TILE

4" CURB 42" KNEE WALL GLASS ABOVE

PANTRY CABINETS

15X24 NICHE'

FILL WINDOW

FLOORING TILE

REP

REMOVE WALL

REMOVE WALL

BLOCKING

REP

REMOVE LOAD BEARING WALL INSTALL HEADER INTO CEILING-18" TRIPLE LVL REMOVE DOOR FILL WALL

REMOVE WALL

ENCLOSE GARAGE REMOVE DOOR FILL WALL

REMOVE WALL

FILL WALL

CONSTRUCT WALL

REMOVE WALL

REMOVE WALL

REMOVE WALL

REMOVE DOOR FILL WALL REMOVE WALL

DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION

REMOVE WALL

CONSTRUCT WALL

EXISTING CONCRETE DRIVEWAY CLNG HGHT: 89" NEW COLUMN-REMOVE RAILING

EXISTING SIDE WALK

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

1/23/2018

DEMOLITION PLAN MAIN LEVEL SCALE: 1/4" = 1' - 0"

SHEET: 8 OF 21


678-525-2829 jennyaburger @gmail.com

JENNY BURGER

COMPUTER DRAWING TECHNICIAN

79'-3"

E3

39'

10'-8"

18'-4 5/8"

20'-2 7/8"

6'-10 7/8"

DECK 177 SQ FT

10 5/8"

2'-3"

5'

MASTER BDRM 138 SQ FT

3'

15X24 NICHE'

59 SQ FT FLOORING TILE

10'-11"

4" CURB

42" KNEE WALL GLASS ABOVE

RELEASED FOR CONSTRUCTION

2'-9"

8'-7 1/4"

5'-4 1/2"

12'-1 1/4"

8'-7 3/4"

8'-7 3/4"

39 SQ FT

FLOORING TILE

10'-11"

12'-1 1/4"

5'-3 1/4"

MASTER BATH

BATH

5"

3'

3'-3 1/4"

8'-6"

4'-2 1/2"

7'-6"

4'-10 1/8" CONFIRM THIS WINDOW HEIGHT BEFORE ORDERING.

1'-4"

TUB SHOWER

2'-9"

3DB33

W3336R

SHOWER 16 SQ FT

6"

3'

12'-8 3/8"

1'-9 3/8"

8 SQ FT

14 SQ FT

11 SQ FT

3'-2 7/8"

LIVING ROOM

110 SQ FT

9'-1"

11'-1" BEDROOM 143 SQ FT

PORCH 28 SQ FT

CLNG HGHT: 89"

1'-11"

3'

2"

3'

2'

3'-5"

3'

2"

5'

19'-4 1/8"

2"

3'

8 3/8"

NEW COLUMN-REMOVE RAILING

2'-5 1/2"

3'

2"

3'

2'-5"

2'-6"

3'

2"

3'

7' EXISTING SIDE WALK

LIVING AREA

59'-10 7/8"

1800 SQ FT

E1

2'-5"

DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION

4'

EXISTING CONCRETE DRIVEWAY

11'-0 1/2" OFFICE

10'

25'-1 7/8"

8 3/8"

10'-1"

12'-7"

649 SQ FT

10'

132 SQ FT

E4

3'

CLOSET

S1

6"

3'-5"

NICHE'

1'-0 1/2"

3'-3"

4'-4 3/4"

CLOSET

29'-9 3/4"

CLOSET 33 SQ FT 7'-5 5/8"

3'-3"

19'-6 5/8"

40'-2 1/4"

4'-4 1/2"

15'-7 3/8"

32'-10 1/2"

REMOVE LOAD BEARING WALL INSTALL HEADER INTO CEILING-18" TRIPLE LVL

3'-1"

OPEN BELOW 31 SQ FT

2'-5 3/4"

DINING

REMOVE WALL

DN

10'-0 1/8"

3'-4"

8 1/2"

3'-11 1/2"

3'-1"

45'-5"

3'-5 1/2"

REMOVE WALL

3'-3"

FILL WINDOW

1'-1"

8 3/8"

CONSTRUCT WALL

3'

8 1/2"

10'-11"

BLOCKING

13'-1"

339 SQ FT

1'-1" 7 7/8"

3'

6'-10 7/8"

ENCLOSE GARAGE

7'-6"

2'-9 7/8"

2'-8 3/8"

10'-1"

CAR PORT

4 1/2"

8'-6"

REP

18'-7 5/8"

CONSTRUCT WALL

1'-1"

3'

39'

25'-6 3/4"

7'-7 1/8"

5'-4" 3'

13'-1"

10'-8"

4 1/2"

4'-8 3/4"

3'-10"

4'-8 3/4"

8 1/2"

8 1/2"

3'

4 1/2"

8'-9"

3'-10"

5'-5 1/4"

1'-3"

PANTRY CABINETS

1'-5"

3'-3 1/4"

180 SQ FT

U1001290R

CLNG HGHT: 117" FLOORING: TILE

12'-1 1/4"

KITCHEN

8 1/2"

8 5/8"

6'-10 7/8"

3'

20'-8" B36R

UP

5'-4"

1'-11 1/2"

WATER 15 WASTE

1'

6'-8"

71 SQ FT

LCB36R

8 1/2"

4 1/2"

5'-6"

3DB15

12'-2"

B36

13'-6" ELECTRIC RANGE MICROWAVE VENT

LAUNDRY

1'-10"

B30R

1'-3"

8 3/8"

5'-4 1/8"

3'-6 5/8"

1'-10" 3'

6'-8"

3DB24

WASHER DRYER

E2 26'-11 7/8"

W3336

DW

8'-3 5/8"

Elevation 2

3'

W3636R

3'

MICROWAVE VENT

B24

10'-8"

8 1/2"

W2436 W3018R

REP

PROPOSED FLOOR PLAN-MAIN LEVEL 2X4 STUDS INTERIOR DIMENSIONS ARE FROM DRYWALL TO DRYWALL CEILING HEIGHT: 94.75" MAIN FLOORING: LAMINATE WOOD FLOOR, CARPET IN BEDROOMS, CONFIRM BATH FLOORING.

8 3/8"

3'-8 7/8"

W2436

8 1/2"

5'

7'-11 7/8"

8 3/8" 11 5/8" 8 3/8"

18'-9 1/8"

1'-8"

4 1/2"

10'-8"

8 3/8" 11 5/8" 8 3/8"

8 1/2"

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

1/23/2018

PROPOSED FLOOR PLAN MAIN LEVEL SCALE: 1/4" = 1' - 0"

SHEET: 9 OF 21


678-525-2829 jennyaburger @gmail.com

JENNY BURGER

COMPUTER DRAWING TECHNICIAN

PROPOSED FLOOR PLAN-LOWER LEVEL BASEMENT 2X4 STUDS INTERIOR DIMENSIONS ARE FROM DRYWALL TO DRYWALL CEILING HEIGHT: 97" FLOOR JOIST ABOVE: 9.25" MAIN FLOORING: HARDWOOD, TILE IN BATHS AND LAUNDRY REMOVE PANELING AND DROPPED CEILING AND INSTALL DRYWALL. FURR OUT CINDER BLOCK BASEMENT WALLS WITH 2X4'S AND DRYWALL.

E3

3.5X5.5 POST LINE FROM EXISTING DECK ABOVE

79'-3" 2'-2"

9'-0 3/4"

8"

7'-5 3/8"

8"

18'-5 7/8"

8"

5'-5"

8"

4 1/2"

22'-7 1/2"

6'-8"

4 1/2"

3'-3 1/2" 8"

AN OPTION WOULD BE TO MAKE THIS BATH ROOM LARGER AND A JACK AND JILL. 3.5X5.5 POST

3'-1" 7'-11" 4 1/2" 6'-5" 5'-3 1/2" 8"

29'-6 1/2"

8"

79'-3" LIVING AREA 1353 SQ FT

E1

DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION

8"

9 1/2"

1'-1 1/2"

VALVE ACCESS

REBUILD DRYWALL SOFFIT TO CONCEAL DUCT WORK

4'-6"

REF.

3' 28'-4 3/8"

2'-2 1/2"

1' 7'-3" 7'-5"

BAR

4 1/2"

BUILD 40 1/2" TALL KNEE WALL

12'-3"

6'-5"

1'-0 1/2"

HALL

STORAGE EXISTING STEEL POST 35 SQ FT

REMOVE WINDOW BOX SEAT

29'-6"

60 SQ FT

CHRIS, I COULD NOT SEE WHAT WAS IN THIS AREA. CAN WE USE THIS SPACE?

4 1/2"

E4

2'-9 1/2"

4X15.5 POST

S1

32'-10 1/2"

635 SQ FT

5'

3'-6" 4X15.5 POST

1/8"

4X15.5 POST

4 1/2"

FAMILY ROOM

5'-8"

6'-4 1/4"

6'-5"

OPEN RAILING

LOAD BEARING WALL

DOTTED LINES REPRESENT WALLS TO BE REMOVED

4'-8"

8X15.5 POST

233 SQ FT

8"

7'-11"

UP

10'-9 7/8"

LOAD BEARING WALL

5' 30 SQ FT

16'-0 7/8"

8'-7 1/2"

3'-6"

3'-3"

1/8" 1'-1 1/2"

6'

DOTTED LINES REPRESENT WALLS TO BE REMOVED

5'

9'-8 3/8"

2'-9" 1'

CLOSET

UTILITY STORAGE UNFINISHED

17'-2 1/8"

2'-6 1/8"

14 SQ FT

2'-10 1/2"

15'

CLOSET

2'-2"

8 1/2"

5'-1"

5'-1" UNSPECIFIED

3'-1"

INSTALL COLUMN AROUND EXISTING STEEL POST

1'-6"

2'-6 1/8"

TUB SHOWER

43 SQ FT

CONCRETE GARAGE FLOOR ABOVE

1'-8"

178 SQ FT

18'-4" REBUILD DRYWALL SOFFIT TO CONCEAL DUCT WORK

28'

24'-2"

INSTALL COLUMN AROUND LOAD BEARING WALL ABOVE EXISTING STEEL POST

BEDROOM

8X15.5 POST

32'-10 1/2"

13'-5" INSTALL COLUMN AROUND EXISTING STEEL POST

KEEP AND REUSE WATER HEATER

BATH

2'-8"

7'-0 1/2"

48 SQ FT

4 1/2"

E2

182 SQ FT

18'-9 1/2"

WH

14'-11"

8"

8X15.5 POST

5 TON DUAL ZONE HVAC

BEDROOM

6'-7 1/2"

2'-10 5/8"

12'-2 1/2"

1'-11 3/8"

50 SQ FT

12'-2"

8'-10 1/2"

5'-2 3/8"

59 SQ FT

7'-1 7/8"

SOFFIT TO CONCEAL DUCT WORK

3'-10"

SOFFIT TO CONCEAL DUCT WORK

"

CRAWL SPACE

REMOVE

8'-3 5/8"

-4

CRAWL SPACE

4X15.5 POST

5'-0 3/8"

4X15.5 POST

3'

Elevation 2

3'-10 1/2"

8"

5'-3"

1'-3"

4X15.5 POST

8"

1' 8"

2'-2"

3'-2"

RELEASED FOR CONSTRUCTION

8"

EXISTING PLUMBING PIPE

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

1/23/2018

PROPOSED FLOOR PLAN LOWER BASEMENT LEVEL SCALE: 1/4" = 1' - 0"

SHEET: 10 OF 21


678-525-2829 jennyaburger @gmail.com

JENNY BURGER

COMPUTER DRAWING TECHNICIAN

FILL RECESS WITH NON-SHRINK GROUT WHEN STEEL HAS BEEN SET

1'

W01

7'-10 3/4"

2'

12" SQUARE X 3" DEEP RECESS

10 X 10X 1/2 BASE PLATE WITH (4) - 5/8" O THREADED ROD ANCHOR BOLTS WITH MIN. 5" EMBEDMENT, ADHERE WITH SIMPSON "SET-XP" ADHESIVE

W01 W07 5068

D15

D02

D05

FOUR #4 REBAR EACH WAY

2' NEW FOOTING FOR PERIMETER OF HOUSE

BRICK VENEER 1" AIR GAP WEEP HOLES METAL FLASHING

D04

EXISTING 24"X24"X24" REINFORCED CONCRETE FOOTINGS.

CONCRETE SLAB REINFORCING STEEL AS REQUIRED VAPOR BARRIER 4" GRAVEL BASE

DRAINAGE SYSTEM

CMU Basement Foundation w/ Brick Ledge: Unfinished (print at 1"=1') CHIEF ARCHITECT, INC. MAKES NO WARRANTY THAT THESE DRAWINGS COMPLY WITH ANY BUILDING CODES AND PROVIDED TO YOU "AS IS". PLEASE REFER TO YOUR END USER SOFTWARE LICENSE AGREEMENT FOR MORE INFORMATION ABOUT THE TERMS AND CONDITIONS PURSUANT TO THESE DRAWINGS. © Chief Architect 2006

EXISTING 4" THICK REINFORCED CONCRETE SLAB FLOOR

DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION

D03

W06

8'-1"

STEEL POST

D11

W06

2x TREATED MUDSILL SILL SEAL CAST-IN-PLACE ANCHOR BOLT

EXISTING 8" THICK CMU WALL CMU FOUNDATION WALL REINFORCING STEEL AS REQUIRED CONCRETE FOOTING

STEEL POST

W06

STEEL POST

EXISTING 9.25" FLOOR JOIST

T

9 1/4"

D13

RELEASED FOR CONSTRUCTION

3/16"

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

1/23/2018

HOUSE CROSS SECTION & DETAILS SCALE: 1/4" = 1' - 0"

SHEET: 11 OF 21


678-525-2829 jennyaburger @gmail.com

EXISTING ROOF PLAN

JENNY BURGER

4 : 12

4 : 12

RELEASED FOR CONSTRUCTION

4 : 12

COMPUTER DRAWING TECHNICIAN

DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION

4 : 12

4 : 12

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

1/23/2018

EXISTING ROOF FRAMING PLAN EXISTING RAFTERS: 2X10 (16" O.C.) RIDGE 2X12

PROPOSED ROOF AND ROOF FRAMING PLANS SCALE: 1/4" = 1' - 0"

SHEET: 12 OF 21


678-525-2829 jennyaburger @gmail.com

EXISTING DECK FLOOR FRAMING PLAN 2X8 (16" O.C.)

JENNY BURGER

LOAD BEARING WALL

LOAD BEARING WALL ABOVE

RELEASED FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

EXISTING FLOOR FRAMING PLAN 2X10 (16" O.C.) FOR THE MAIN LEVEL. DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION

THE WALLS SHOWN ARE BASEMENT WALLS

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.

REMOVE LOAD BEARING WALL INSTALL HEADER 18" LVL INTO CEILING (TRIPLE LVL)

SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

1/23/2018

CEILING FRAMING PLAN 2X6 (16" O.C.) MAIN LEVEL

FLOOR FRAMING PLAN & CEILING FRAMING PLAN SCALE: 1/4" = 1' - 0"

SHEET: 13 OF 21


678-525-2829 jennyaburger @gmail.com

JENNY BURGER

COMPUTER DRAWING TECHNICIAN

4X15.5 POST

RELEASED FOR CONSTRUCTION

S

S

E3

4X15.5 POST

8X15.5 POST

WH

S E2

UP

8X15.5 POST

LOAD BEARING WALL ABOVE

LOAD BEARING WALL

S1 E4

8X15.5 POST

DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION

S

S

S

4X15.5 POST

4X15.5 POST

4X15.5 POST

REF.

ALL EXTERIOR WALLS ARE LOAD BEARING

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

1/23/2018

PROPOSED BASEMENTFLPL-RED LINES MAIN LEVEL SCALE: 1/4" = 1' - 0"

SHEET: 14 OF 21


678-525-2829 jennyaburger @gmail.com

JENNY BURGER

RELEASED FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

PROPOSED ELEVATION 1 FRONT

4 : 12 4 : 12

8'-4"

D01

9'-11"

9'-4"

W07

W07

W07

W08

W07

8" COLUMN

8" W07

W07

W07

W07

D14

GRADE

DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION

GRADE

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

1/23/2018

PROPOSED ELEVATION 1 SCALE: 1/4" = 1' - 0"

SHEET: 15 OF 21


678-525-2829 jennyaburger @gmail.com

JENNY BURGER

COMPUTER DRAWING TECHNICIAN

PROPOSED ELEVATION 2 LEFT SIDE 10819VT

16'-9"

RELEASED FOR CONSTRUCTION

W03

3'

W03

7'-5"

W02

WROUGHT IRON COLUMN

4 : 12

2X8 JOIST

8'-10"

8'-3"

GRADE

ST A

U I RS

P

GRADE

PROPOSED ELEVATION 4 RIGHT SIDE

W07

W07

16'-9"

6X6 PT POST (TYP)

W04

EXISTING SUPPORT POST TO REMAIN

W04

DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION

4 : 12

D21

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

1/23/2018

PROPOSED ELEVATIONS 2 LEFT SIDE & 4 RIGHT SIDE SCALE: 1/4" = 1' - 0"

SHEET: 16 OF 21


678-525-2829 jennyaburger @gmail.com

JENNY BURGER

RELEASED FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

SINCE THIS WINDOW IS IN THE BATHROOM, YOU MAY WANT TO ORDER A SHORTER ONE TO MATCH THE NEXT TO IT. PROPOSED ELEVATION 3 REAR

4 : 12

W05 W07

W05

W04

W01

W01

W07 D15

16'-9"

3'

6X6 PT POST (TYP) EXISTING SUPPORT POST TO REMAIN

W06

D11

W06

GRADE

DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION

W06

8'-3"

W04 W06

8'-10"

2X8 JOIST

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

1/23/2018

PROPOSED ELEVATION 3 REAR SCALE: 1/4" = 1' - 0"

SHEET: 17 OF 21


678-525-2829 jennyaburger @gmail.com

JENNY BURGER

D11

W06

W06

W04 W06

D16

D05

DOES THIS SPACE NEED A DOOR?

D21

Number D01 D02 D03 D04 D05 D11 D16 D21

Label Qty 3068 1 2868 1 2068 2 2868 2 2668 1 3068 1 3968 1 CONFIRMX68 1

Number W04 W06

Label Qty 3032DH 3 3046DH 4

LOAD BEARING WALL ABOVE

D04

Height 80 " 80 " 80 " 80 " 80 " 80 " 80 " 80 "

Door Schedule Description MECHANICAL ROOM DOOR NEW STORAGE ROOM DOOR CLOSET DOOR BEDROOM DOOR BATHROOM DOOR BACK DOOR TEMPERED GLASS NEW DOUBLE CRAWLSPACE DOOR SLIDING BASEMENT DOOR TEMPERED GLASS

Header 2x6x41" (2) 2x6x37" (2) 2x6x29" (2) 2x6x37" (2) 2x6x35" (2) 2x6x41" (2) 2x6x50" (2) 2x10x98" (2)

Thickness 1 3/4" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/4" 1 3/8" 1 3/4"

Comments

WITH LOCK CONFIRM DIMENSIONS TEMERED GLASS

W04

3068

D03

Width 36 " 32 " 24 " 32 " 30 " 36 " 45 " 93 "

D04

LOAD BEARING WALL

D03

Size 3068 L IN 2868 R IN 2068 R IN 2868 R IN 2668 L IN 3068 R EX 3968 L/R IN 7968 R EX

W04 D01 D02 Window Schedule Size Width 3032DH 36 " 3046DH 36 "

Height 38 " 54 "

Description Double Hung Double Hung

Header Comments 2x6x40" (2) 2x6x40" (2)

DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION

W06

RELEASED FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

1/23/2018

DOORS/WINDOWS LOWER BASEMENT LEVEL SCALE: 1/4" = 1' - 0"

SHEET: 18 OF 21


678-525-2829 jennyaburger @gmail.com

JENNY BURGER

COMPUTER DRAWING TECHNICIAN

DOES THIS WINDOW NEED TO BE SHORTER TO MATCH THE ONE NEXT TO IT? W01

W01

D15

W07

W05

W05

W04

W07

D12

W02

D04

D03

D13 D02 W07 D07 W03 5068

D05

D06

D10

6168

DOES THIS SPACE NEED A DOOR?

RELEASED FOR CONSTRUCTION

D09

D08 W07

3068

4068

W03

D14 W07

W07

W07

W08

W07

W07

Number D01 D02 D03 D04 D05 D06 D07 D08 D09 D10 D11 D12 D13 D14 D15

Label 18080 2068 2068 2068 2868 2068 2668 2468 2668 2668 6068 2468 3068 3068 3068

Qty 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Size 18080 2068 L IN 2068 R IN 2068 R IN 2868 L IN 2068 R IN 2668 R IN 2468 L IN 2668 R IN 2668 L IN 6068 R IN 2468 R IN 3068 L EX 3068 L IN 3068 R EX

Number W01 W02 W03 W04 W05 W07 W08

Label Qty 2832DH 2 3031DH 1 3031DH 2 3046DH 1 3032DH 2 3046DH 12 5046FX 1

Size 2832DH 3031DH 3031DH 3046DH 3032DH 3046DH 5046FX

Width 32 " 36 " 36 " 36 " 36 " 36 " 60 "

Width 216 " 24 " 24 " 24 " 32 " 24 " 30 " 28 " 30 " 30 " 72 " 28 " 36 " 36 " 36 " Height 38 " 37 " 37 " 54 " 38 " 54 " 54 "

Door Schedule Height Description 96 " Garage-Garage Door CHD02 80 " BATHROOM DOOR 80 " TEMERED GLASS SHOWER DOOR 80 " MASTER BATH DOOR 80 " BEDROOM DOORS 80 " Hinged-Door P04 80 " Hinged-Door P04 80 " BEDROOM DOORS 80 " LAUNDRY DOOR 80 " BEDROOM DOORS 80 " SLIDING DOORS 80 " MASTER BATH DOOR 80 " GARAGE DOOR 80 " FRONT DOOR TEMPERED GLASS 80 " BACK Schedule DOOR TEMPERED GLASS Window Description Double Hung Double Hung NEW DBL HUNG GARAGE WINDOW Double Hung CONFIRM THIS WINDOW HEIGHT. Double Hung Double Hung Fixed Glass

Header 2x12x224" (2) 2x6x29" (2) 2x6x29" (2) 2x6x29" (2) 2x6x37" (2) 2x6x29" (2) 2x6x35" (2) 2x6x33" (2) 2x6x35" (2) 2x6x35" (2) 2x10x77" (2) 2x6x33" (2) 2x6x41" (2) 2x6x41" (2) 2x6x41" (2)

Thickness 1 3/4" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/4" 1 3/4" 1 3/4"

W07

W07

W07

Comments

DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION

D01

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.

Header Comments 2x6x36" (2) 2x6x40" (2) 2x6x40" (2) 2x6x40" (2) 2x6x40" (2) 2x6x40" (2) 2x8x64" (2)

SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

1/23/2018

DOOR/WINDOWS MAIN LEVEL SCALE: 1/4" = 1' - 0"

SHEET: 19 OF 21


678-525-2829 jennyaburger @gmail.com

JENNY BURGER

RELEASED FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

WP

GFCI GFCI

CW

GFCI

DW

C

GFCI

GD

TUB SHOWER EXHAUST FAN CAN

GFCI 3 3

R

R

R

R

R

GFCI

R

R

R

R

C

R

3

GFCI

GFCI

R

3 3 3

R

R R

R

R EXHAUST FAN CAN

GFCI

C

R

GFCI 3

SD

R

SD

R

R

3

T

3DM

SD

3

DM 3DM

R

R

R

ATTIC ACCESS

R

R

VENT

R

R

R

CENTER FAN WITH WINDOW

R

SD

R

R

3

C C 3DM

WP

ELECTRICAL SCHEDULE CONFIRM CABLE JACK LOCATIONS NUMBER QTY ATTACHED TO DESCRIPTION COMMENTS E01 2 WALL PORCH SCONCE E02 1 WALL SPOTLIGHT 2 MOTION SENSOR E03 5 CEILING CEILING FAN WITH LIGHT E04 2 CEILING STAIRWELL LIGHTS E05 3 WALL VANITY SCONCE E06 1 CEILING MASTER CLOSET LIGHT E07 2 CEILING VAPOR SHOWER LIGHT E08 1 CEILING CLOSET LIGHT E09 1 WALL CLOTHES DRYER E10 1 WALL CLOTHES WASHER E11 1 WALL DISHWASHER E12 1 CEILING NICHE' LIGHT E14 1 WALL REFRIGERATOR E15 1 WALL GARBAGE DISPOSAL E16 10 FLOOR GFCI E17 4 CEILING SMOKE DETECTOR E18 1 CEILING DINING ROOM LIGHT E21 3 CEILING EXHAUST FAN CAN LONG SURFACE MOUNTED E22 3 CEILING FLUORESCENT LIGHT [96W9D] E23 2 CEILING BANKER'S PENDANT E24 1 WALL THERMOSTAT E25 5 WALL CABLE JACK E26 28 WALL SINGLE POLE E27 3 WALL THREE WAY (SLIDING DIMMER) E28 1 WALL SINGLE POLE (SLIDING DIMMER) E29 20 CEILING RECESSED DOWN LIGHT 6 E30 10 WALL THREE WAY E31 5 UNDER CABINET LIGHT E32 2 WALL 220V WEATHERPROOF E33 39 WALL DUPLEX

DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION

CD

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

1/23/2018

LIGHTING ELECTRICAL PLAN MAIN LEVEL SCALE: 1/4" = 1' - 0"

SHEET: 20 OF 21


678-525-2829 jennyaburger @gmail.com

JENNY BURGER

RELEASED FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

WP

EP

WP 3DM GFCI

R

R

R

R

R

R

R

R

R

R

R

C

R C

R

C

C

EXHAUST FAN CAN

WH

3

LOAD BEARING WALL ABOVE 3

3DM

SD

R

SD

R

R

R

LOAD BEARING WALL

3

R

R

R

T 3

R

SD

R

R

REF.

R

R

SD

C

DM

DM

C

C

ELECTRICAL SCHEDULE CONFIRM CABLE JACK LOCATIONS NUMBER QTY ATTACHED TO DESCRIPTION COMMENTS E01 1 WALL ELECTRICAL PANEL E02 2 WALL EXTERIOR SCONCE E03 1 CEILING EXHAST FAN CAN E04 1 WALL VANITY SCONCE E05 1 WALL REFRIGERATOR E06 4 CEILING SMOKE DETECTOR E07 1 FLOOR GFCI E08 2 CEILING CEILING FAN WITH LIGHT E09 2 CEILING CLOSET LIGHT LONG SURFACE MOUNTED E10 4 CEILING FLUORESCENT LIGHT [72W6 3/4D] E11 1 CEILING RECESSED VAPOR LIGHT E13 7 WALL CABLE JACK E14 14 WALL SINGLE POLE E15 4 WALL THREE WAY E16 20 CEILING RECESSED DOWN LIGHT 6 E18 2 FLOOR 220V E19 3 CEILING BAR PENDANTS E20 2 WALL THREE WAY (SLIDING DIMMER) E21 2 WALL SINGLE POLE (SLIDING DIMMER) E22 2 UNDER CABINET LIGHT E23 2 WALL 220V WEATHERPROOF E24 31 WALL DUPLEX E25 1 WALL THERMOSTAT

DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION

TUB SHOWER

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

1/23/2018

LIGHTING ELECTRICAL PLAN BASEMENT LEVEL SCALE: 1/4" = 1' - 0"

SHEET: 21 OF 21