DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION
• International Building Code, 2012 Edition, with Georgia Amendments (2015) • International Residential Code, 2012 Edition, with Georgia Amendments (2015) • International Fire Code, 2012 Edition, with Georgia Amendments (2013) • International Plumbing Code, 2012 Edition, with Georgia Amendments (2015) • International Mechanical Code, 2012 Edition, with Georgia Amendments (2012) • International Fuel Gas Code, 2012 Edition, with Georgia Amendments (2015) • National Electrical Code, 2014 Edition, with no Georgia Amendments • International Energy Conservation Code, 20011 Edition, with Georgia Supplements and Amendments (2011) (2012) • 2012 NFPA 101 – Life Safety Code with state Amendments (2013)
Layout Page Table Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
Description TITLE SHEET EXISTING FLOOR PLAN MAIN LEVEL EXISTING BASEMENT FLOOR PLAN-RED LINES MAIN LEVEL EXISTING FLOOR PLAN LOWER BASEMENT LEVEL EXISTING ELEVATION 1 & 2 FRONT & LEFT SIDE EXISTING ELEVATIONS 3 & 4, REAR AND RIGHT SIDE EXISTING ROOF PLAN DEMOLITION PLAN MAIN LEVEL PROPOSED FLOOR PLAN MAIN LEVEL PROPOSED FLOOR PLAN LOWER BASEMENT LEVEL HOUSE CROSS SECTION & DETAILS PROPOSED ROOF AND ROOF FRAMING PLANS FLOOR FRAMING PLAN & CEILING FRAMING PLAN PROPOSED BASEMENTFLPL-RED LINES MAIN LEVEL PROPOSED ELEVATION 1 PROPOSED ELEVATIONS 2 LEFT SIDE & 4 RIGHT SIDE PROPOSED ELEVATION 3 REAR DOORS/WINDOWS LOWER BASEMENT LEVEL DOOR/WINDOWS MAIN LEVEL LIGHTING ELECTRICAL PLAN MAIN LEVEL LIGHTING ELECTRICAL PLAN BASEMENT LEVEL
DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION
Effective January 1, 2014 The following will be the State of Georgia's minimum Standard Construction Codes:
RELEASED FOR CONSTRUCTION
NO CHANGES TO THE FOOT PRINT. A LOAD BEARING INTERIOR WALL WILL BE REMOVED AND AN LVL RECESSED INTO THE CEILING WILL BE INSTALLED.
THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/23/2018
TITLE SHEET SCALE: 1/4" = 1' - 0"
SHEET: 1 OF 21
678-525-2829 jennyaburger @gmail.com
JENNY BURGER
COMPUTER DRAWING TECHNICIAN
E3
39'
10'-8"
18'-4 5/8"
20'-2 7/8"
6'-10 7/8"
17'-11"
79'-3"
3046DH
3046DH
5'
8 3/8"
3946FX
MASTER BDRM
2'-9"
FLOORING TILE
247 SQ FT
187 SQ FT FLOORING TILE
DN OPEN BELOW 23 SQ FT
LOAD BEARING WALL
18'-0 7/8"
2668
21'-8 7/8" 3'-6"
3046DH
15'-3 5/8"
3'-1"
2668
2668
HALL 13 SQ FT
1'-3 7/8"
7'-4 7/8"
7'-5 5/8" CLOSET
2'-8"
12 SQ FT
3'-4"
2668
10'-1"
42'-11"
3'-11 1/2"
HALL 87 SQ FT
7'
10 SQ FT
51068
2868
3068
LIVING ROOM
15'-3 5/8" 12'-7"
17'-4"
BEDROOM 143 SQ FT
BEDROOM
9'-1"
8 3/8"
8 3/8"
41 SQ FT
12'-7"
ENTRY
13'-7 1/2"
4068
7'-2 1/2"
236 SQ FT
130 SQ FT
3068 3046DH
PORCH
4'
28 SQ FT
EXISTING CONCRETE DRIVEWAY
8 3/8"
5046FX
3'-10 3/4"
3046DH
3'-6 5/8"
3046DH 3046DH
CLNG HGHT: 89"
8 3/8"
IRON RAILING
1'-11" 8 1/2"
3'
2"
3'
2'
3'-5"
3'
2"
5'
EXISTING SIDE WALK
10'-1"
4 1/2"
18'-0 7/8" LIVING AREA 1809 SQ FT
2"
7' 3'
3'-3 7/8" 4 1/2"
3046DH 3046DH 2'-5 1/2"
8 1/2" 6'-4 1/2"
6"
5 SQ FT
6 SQ FT
4'-9" CLOSET
18 SQ FT
3'
CLOSET
2'-6 1/4"
2'-1 3/4"
CLOSET
2'-5 3/4"
CLOSET
2668
3046DH
DINING 132 SQ FT
2'-1 1/4"
2668
1'-0 1/2"
6168
4'-2 3/4"
2'-11"
2068
2068
11'-0 2" 1/2" 3' 3' 11'-0 1/2"
3046DH 3046DH 2'-5" 4 1/2"
2'-6"
3'
11'-1" 2" 11'-1"
3'
32'-10 1/2"
12'-1 1/4"
WATER
2'-4 1/8" 4 1/2" 1'-7 7/8" 4 1/2"
8'-7 3/4"
FLOORING TILE
E4
DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION
3032DH
BATH
8 1/2"
RELEASED FOR CONSTRUCTION
5"
2068
13'-1"
360 SQ FT
3'
MASTER BATH
59 SQ FT
19'-6 5/8"
CAR PORT
8'-4 5/8"
TOILET
FAMILY ROOM
25'-6 3/4"
7'-7 1/8"
12'-1 1/4"
2 5/8"
3'-9"
1'-3" 4 1/2"
4 1/2"
10'-8"
3'-10"
180 SQ FT
13'-1"
8'-9"
8 1/2"
3'
KITCHEN
7'-6"
26'-11 7/8"
3'-10"
3'
37 SQ FT
9 1/8"
E2
19'-4 1/8"
TUB SHOWER
WATER
8'-3 5/8" 4'-8 3/4"
UP
8 1/2"
CLNG HGHT: 117" FLOORING: TILE
3032DH
1'-1"
3' 1'-11 1/2"
5 1/2" 6"
3'
19'-9 1/2"
3046DH
5'-4"
7 7/8"1'-1"
3'
8 1/2"
15'-3 5/8"
4 1/2"
12'-2" 13'-6"
2668
6'-8"
3031DH
71 SQ FT
1'-1" 2'-9 7/8"
3'
6'-1"
1'-10" 3'
9'-10"
1'-10"
6'-8" 8 1/2"
3068
LAUNDRY
3068
32'-10 1/2"
Elevation 2
8 3/8"
2832DH 2832DH
8 1/2" 1'-5"
5'-4"
4 1/2"
4'-1 3/8"
8'-7 1/4" 14'-1 5/8" 12'-1 1/4"
DECK 177 SQ FT
EXISTING FLOOR PLAN-MAIN LEVEL 2X4 STUDS INTERIOR DIMENSIONS ARE FROM DRYWALL TO DRYWALL CEILING HEIGHT: 94.75" MAIN FLOORING: HARDWOOD
1'-3" 8 1/2"
3'
8 5/8"
3'
3'-8 7/8"
6'-10 7/8"
6"
3'-0 5/8"
2'-8"
4 1/2"
5'-6"
3'-10" 1'-8"
2"
8 3/8"
5'-4 1/8"
1'-4"
2'-8"
8 1/2"
8 3/8" 11 5/8" 8 3/8"
9'-10"
7'-11 7/8"
1'-8"
4 1/2"
18'-4 5/8"
8 3/8" 11 5/8" 8 3/8"
4 1/2"
10'-8"
9'-11"
8 1/2"
2'-5" 8 1/2"
59'-10 7/8"
E1
THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/23/2018
EXISTING FLOOR PLAN MAIN LEVEL SCALE: 1/4" = 1' - 0"
SHEET: 2 OF 21
678-525-2829 jennyaburger @gmail.com
JENNY BURGER
COMPUTER DRAWING TECHNICIAN
EP
4X15.5 POST
8X15.5 POST
WH
4X15.5 POST
RELEASED FOR CONSTRUCTION
E3
E2
8X15.5 POST
E4
4X15.5 POST
4X15.5 POST
4X15.5 POST
E1
DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION
8X15.5 POST
UP
THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/23/2018
EXISTING BASEMENT FLOOR PLAN-RED LINES MAIN LEVEL SCALE: 1/4" = 1' - 0"
SHEET: 3 OF 21
678-525-2829 jennyaburger @gmail.com
JENNY BURGER
COMPUTER DRAWING TECHNICIAN
E3
EXISTING FLOOR PLAN-LOWER LEVEL BASEMENT 2X4 STUDS INTERIOR DIMENSIONS ARE FROM DRYWALL TO DRYWALL CEILING HEIGHT: 97" FLOOR JOIST ABOVE: 9.25" MAIN FLOORING: CARPET AND TILE 8"
7'-5 3/8"
8"
18'-5 7/8"
8"
5'-5"
8"
4 1/2"
22'-7 1/2"
6'-8"
4 1/2"
RELEASED FOR CONSTRUCTION
9'-0 3/4"
79'-3" 3'-3 1/2" 8"
1'
3046DH
TUB SHOWER
E2
625 SQ FT
3'-1" 4 1/2"
E4
2668 CRAWL SPACE
UNFINISHED
18'-9"
12'-4"
8X15.5 POST
32 SQ FT
7'-9"
2068 7'-5"
17'-2 1/8"
8"
18'-9"
4 1/2" 2'-1 7/8" 4 1/2"
SOFFIT
33 SQ FT VALVE ACCESS
8"
4 1/2"
6'-8 1/2"
4 1/2" 5'-3 1/2"
8"
2'-2"
STEEL POST
8"
1'-1 1/2"
2'-2 3/8"
CLOSET
4'-6"
BAR
4X15.5 POST
4'-6"
4X15.5 POST
8"
4X15.5 POST
6'-5"
WINDOW BOX SEAT
9'-4"
36'-11"
6'-5"
1'-0 1/2"
4 1/2"
13'-1"
CONCRETE GARAGE FLOOR ABOVE
3032DH 3032DH
DROPPED GRID CEILING CARPET
7'-2"
312 SQ FT
32'-10 1/2"
3'-9"
FAMILY ROOM 28'
18'-1 3/4"
13'-11" 5'-8"
STEEL POST
9'-1"
UP
25 SQ FT
7'-5"
STEEL POST
8'-4"
1'
28'-4"
LOAD BEARING POST
8X15.5 POST
25'-4 5/8"
STAIRS STEEL POST
2'-9"
14 SQ FT
13 STEPS 9'-10"
8 1/2"
UNSPECIFIED
7'-11"
2'-10 5/8"
48 SQ FT
4 1/2"
1'-6"
SOFFIT
CONFIRMX68
BATH
18'-4"
2'-8"
7'-11"
8'-3 5/8"
6'-7 1/2"
7'-0 1/2"
6'-5"
748 SQ FT
15'-11"
8"
8'-7"
KEEP AND REUSE WATER HEATER
UNFINISHED
32'-10 1/2"
Elevation 2
WH
3968
50 SQ FT
8X15.5 POST
5'-2 3/8"
CRAWL SPACE
59 SQ FT
3'-10 1/2"
WINDOW BOX SEAT
5'-1"
PLUMBING PIPE
32'-2"
CRAWL SPACE
8"
4X15.5 POST
4X15.5 POST
2668
3'-2"
5'-3"
3'-10"
4X15.5 POST
1'-8"
2'-2"
EP
3046DH 3046DH
3032DH
8"
1'
3068
8"
3046DH
8"
8"
3.5X5.5 POST
8"
29'-6 1/2"
8"
79'-3" LIVING AREA 1626 SQ FT
E1
DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION
2'-2"
3.5X5.5 POST
THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/23/2018
EXISTING FLOOR PLAN LOWER BASEMENT LEVEL SCALE: 1/4" = 1' - 0"
SHEET: 4 OF 21
678-525-2829 jennyaburger @gmail.com
JENNY BURGER
COMPUTER DRAWING TECHNICIAN
EXISTING ELEVATION 1 FRONT
4 : 12
5046FX
3046DH
3046DH 3046DH
3046DH 3046DH
3068
GRADE
GRADE
RELEASED FOR CONSTRUCTION
3068
3046DH
8'-4"
9'-4"
9'-11"
3046DH 3046DH
WROUGHT IRON COLUMN
4 : 12
EXISTING ELEVATION 2 LEFT SIDE 10819VT
16'-9"
3'
7'-5"
3946FX
2X8 JOIST
8'-10"
8'-3"
GRADE
ST A
U I RS
DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION
3031DH
WROUGHT IRON COLUMN
4 : 12
P THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.
GRADE
SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/23/2018
EXISTING ELEVATION 1 & 2 FRONT & LEFT SIDE SCALE: 1/4" = 1' - 0"
SHEET: 5 OF 21
678-525-2829 jennyaburger @gmail.com
JENNY BURGER
COMPUTER DRAWING TECHNICIAN
EXISTING ELEVATION 3 REAR
4 : 12
3032DH
3046DH
2832DH 2832DH 3046DH
RELEASED FOR CONSTRUCTION
3032DH 3046DH
3068
3032DH 3046DH
3046DH 3068
DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION
EXISTING ELEVATION 4 RIGHT SIDE
4 : 12
3046DH
3046DH
16'-9"
3046DH 3046DH
THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.
3032DH 3032DH CONFIRMX68
SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/23/2018
EXISTING ELEVATIONS 3 & 4, REAR AND RIGHT SIDE SCALE: 1/4" = 1' - 0"
SHEET: 6 OF 21
678-525-2829 jennyaburger @gmail.com
JENNY BURGER
4 : 12
RELEASED FOR CONSTRUCTION
COMPUTER DRAWING TECHNICIAN
4 : 12
4 : 12
4 : 12
DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION
4 : 12
THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/23/2018
EXISTING ROOF PLAN SCALE: 1/4" = 1' - 0"
SHEET: 7 OF 21
678-525-2829 jennyaburger @gmail.com
JENNY BURGER
COMPUTER DRAWING TECHNICIAN
RELEASED FOR CONSTRUCTION
DEMOLITION PLAN
CONFIRM THIS WINDOW HEIGHT BEFORE ORDERING.
DW
PROPOSED FLOOR PLAN-MAIN LEVEL 2X4 STUDS INTERIOR DIMENSIONS ARE FROM DRYWALL TO DRYWALL CEILING HEIGHT: 94.75" MAIN FLOORING: LAMINATE WOOD FLOOR, CARPET IN BEDROOMS, CONFIRM BATH FLOORING.
MICROWAVE VENT
TUB SHOWER
WASHER DRYER
WATER
FLOORING TILE
ELECTRIC RANGE MICROWAVE VENT
CLNG HGHT: 117" FLOORING: TILE
4" CURB 42" KNEE WALL GLASS ABOVE
PANTRY CABINETS
15X24 NICHE'
FILL WINDOW
FLOORING TILE
REP
REMOVE WALL
REMOVE WALL
BLOCKING
REP
REMOVE LOAD BEARING WALL INSTALL HEADER INTO CEILING-18" TRIPLE LVL REMOVE DOOR FILL WALL
REMOVE WALL
ENCLOSE GARAGE REMOVE DOOR FILL WALL
REMOVE WALL
FILL WALL
CONSTRUCT WALL
REMOVE WALL
REMOVE WALL
REMOVE WALL
REMOVE DOOR FILL WALL REMOVE WALL
DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION
REMOVE WALL
CONSTRUCT WALL
EXISTING CONCRETE DRIVEWAY CLNG HGHT: 89" NEW COLUMN-REMOVE RAILING
EXISTING SIDE WALK
THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/23/2018
DEMOLITION PLAN MAIN LEVEL SCALE: 1/4" = 1' - 0"
SHEET: 8 OF 21
678-525-2829 jennyaburger @gmail.com
JENNY BURGER
COMPUTER DRAWING TECHNICIAN
79'-3"
E3
39'
10'-8"
18'-4 5/8"
20'-2 7/8"
6'-10 7/8"
DECK 177 SQ FT
10 5/8"
2'-3"
5'
MASTER BDRM 138 SQ FT
3'
15X24 NICHE'
59 SQ FT FLOORING TILE
10'-11"
4" CURB
42" KNEE WALL GLASS ABOVE
RELEASED FOR CONSTRUCTION
2'-9"
8'-7 1/4"
5'-4 1/2"
12'-1 1/4"
8'-7 3/4"
8'-7 3/4"
39 SQ FT
FLOORING TILE
10'-11"
12'-1 1/4"
5'-3 1/4"
MASTER BATH
BATH
5"
3'
3'-3 1/4"
8'-6"
4'-2 1/2"
7'-6"
4'-10 1/8" CONFIRM THIS WINDOW HEIGHT BEFORE ORDERING.
1'-4"
TUB SHOWER
2'-9"
3DB33
W3336R
SHOWER 16 SQ FT
6"
3'
12'-8 3/8"
1'-9 3/8"
8 SQ FT
14 SQ FT
11 SQ FT
3'-2 7/8"
LIVING ROOM
110 SQ FT
9'-1"
11'-1" BEDROOM 143 SQ FT
PORCH 28 SQ FT
CLNG HGHT: 89"
1'-11"
3'
2"
3'
2'
3'-5"
3'
2"
5'
19'-4 1/8"
2"
3'
8 3/8"
NEW COLUMN-REMOVE RAILING
2'-5 1/2"
3'
2"
3'
2'-5"
2'-6"
3'
2"
3'
7' EXISTING SIDE WALK
LIVING AREA
59'-10 7/8"
1800 SQ FT
E1
2'-5"
DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION
4'
EXISTING CONCRETE DRIVEWAY
11'-0 1/2" OFFICE
10'
25'-1 7/8"
8 3/8"
10'-1"
12'-7"
649 SQ FT
10'
132 SQ FT
E4
3'
CLOSET
S1
6"
3'-5"
NICHE'
1'-0 1/2"
3'-3"
4'-4 3/4"
CLOSET
29'-9 3/4"
CLOSET 33 SQ FT 7'-5 5/8"
3'-3"
19'-6 5/8"
40'-2 1/4"
4'-4 1/2"
15'-7 3/8"
32'-10 1/2"
REMOVE LOAD BEARING WALL INSTALL HEADER INTO CEILING-18" TRIPLE LVL
3'-1"
OPEN BELOW 31 SQ FT
2'-5 3/4"
DINING
REMOVE WALL
DN
10'-0 1/8"
3'-4"
8 1/2"
3'-11 1/2"
3'-1"
45'-5"
3'-5 1/2"
REMOVE WALL
3'-3"
FILL WINDOW
1'-1"
8 3/8"
CONSTRUCT WALL
3'
8 1/2"
10'-11"
BLOCKING
13'-1"
339 SQ FT
1'-1" 7 7/8"
3'
6'-10 7/8"
ENCLOSE GARAGE
7'-6"
2'-9 7/8"
2'-8 3/8"
10'-1"
CAR PORT
4 1/2"
8'-6"
REP
18'-7 5/8"
CONSTRUCT WALL
1'-1"
3'
39'
25'-6 3/4"
7'-7 1/8"
5'-4" 3'
13'-1"
10'-8"
4 1/2"
4'-8 3/4"
3'-10"
4'-8 3/4"
8 1/2"
8 1/2"
3'
4 1/2"
8'-9"
3'-10"
5'-5 1/4"
1'-3"
PANTRY CABINETS
1'-5"
3'-3 1/4"
180 SQ FT
U1001290R
CLNG HGHT: 117" FLOORING: TILE
12'-1 1/4"
KITCHEN
8 1/2"
8 5/8"
6'-10 7/8"
3'
20'-8" B36R
UP
5'-4"
1'-11 1/2"
WATER 15 WASTE
1'
6'-8"
71 SQ FT
LCB36R
8 1/2"
4 1/2"
5'-6"
3DB15
12'-2"
B36
13'-6" ELECTRIC RANGE MICROWAVE VENT
LAUNDRY
1'-10"
B30R
1'-3"
8 3/8"
5'-4 1/8"
3'-6 5/8"
1'-10" 3'
6'-8"
3DB24
WASHER DRYER
E2 26'-11 7/8"
W3336
DW
8'-3 5/8"
Elevation 2
3'
W3636R
3'
MICROWAVE VENT
B24
10'-8"
8 1/2"
W2436 W3018R
REP
PROPOSED FLOOR PLAN-MAIN LEVEL 2X4 STUDS INTERIOR DIMENSIONS ARE FROM DRYWALL TO DRYWALL CEILING HEIGHT: 94.75" MAIN FLOORING: LAMINATE WOOD FLOOR, CARPET IN BEDROOMS, CONFIRM BATH FLOORING.
8 3/8"
3'-8 7/8"
W2436
8 1/2"
5'
7'-11 7/8"
8 3/8" 11 5/8" 8 3/8"
18'-9 1/8"
1'-8"
4 1/2"
10'-8"
8 3/8" 11 5/8" 8 3/8"
8 1/2"
THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/23/2018
PROPOSED FLOOR PLAN MAIN LEVEL SCALE: 1/4" = 1' - 0"
SHEET: 9 OF 21
678-525-2829 jennyaburger @gmail.com
JENNY BURGER
COMPUTER DRAWING TECHNICIAN
PROPOSED FLOOR PLAN-LOWER LEVEL BASEMENT 2X4 STUDS INTERIOR DIMENSIONS ARE FROM DRYWALL TO DRYWALL CEILING HEIGHT: 97" FLOOR JOIST ABOVE: 9.25" MAIN FLOORING: HARDWOOD, TILE IN BATHS AND LAUNDRY REMOVE PANELING AND DROPPED CEILING AND INSTALL DRYWALL. FURR OUT CINDER BLOCK BASEMENT WALLS WITH 2X4'S AND DRYWALL.
E3
3.5X5.5 POST LINE FROM EXISTING DECK ABOVE
79'-3" 2'-2"
9'-0 3/4"
8"
7'-5 3/8"
8"
18'-5 7/8"
8"
5'-5"
8"
4 1/2"
22'-7 1/2"
6'-8"
4 1/2"
3'-3 1/2" 8"
AN OPTION WOULD BE TO MAKE THIS BATH ROOM LARGER AND A JACK AND JILL. 3.5X5.5 POST
3'-1" 7'-11" 4 1/2" 6'-5" 5'-3 1/2" 8"
29'-6 1/2"
8"
79'-3" LIVING AREA 1353 SQ FT
E1
DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION
8"
9 1/2"
1'-1 1/2"
VALVE ACCESS
REBUILD DRYWALL SOFFIT TO CONCEAL DUCT WORK
4'-6"
REF.
3' 28'-4 3/8"
2'-2 1/2"
1' 7'-3" 7'-5"
BAR
4 1/2"
BUILD 40 1/2" TALL KNEE WALL
12'-3"
6'-5"
1'-0 1/2"
HALL
STORAGE EXISTING STEEL POST 35 SQ FT
REMOVE WINDOW BOX SEAT
29'-6"
60 SQ FT
CHRIS, I COULD NOT SEE WHAT WAS IN THIS AREA. CAN WE USE THIS SPACE?
4 1/2"
E4
2'-9 1/2"
4X15.5 POST
S1
32'-10 1/2"
635 SQ FT
5'
3'-6" 4X15.5 POST
1/8"
4X15.5 POST
4 1/2"
FAMILY ROOM
5'-8"
6'-4 1/4"
6'-5"
OPEN RAILING
LOAD BEARING WALL
DOTTED LINES REPRESENT WALLS TO BE REMOVED
4'-8"
8X15.5 POST
233 SQ FT
8"
7'-11"
UP
10'-9 7/8"
LOAD BEARING WALL
5' 30 SQ FT
16'-0 7/8"
8'-7 1/2"
3'-6"
3'-3"
1/8" 1'-1 1/2"
6'
DOTTED LINES REPRESENT WALLS TO BE REMOVED
5'
9'-8 3/8"
2'-9" 1'
CLOSET
UTILITY STORAGE UNFINISHED
17'-2 1/8"
2'-6 1/8"
14 SQ FT
2'-10 1/2"
15'
CLOSET
2'-2"
8 1/2"
5'-1"
5'-1" UNSPECIFIED
3'-1"
INSTALL COLUMN AROUND EXISTING STEEL POST
1'-6"
2'-6 1/8"
TUB SHOWER
43 SQ FT
CONCRETE GARAGE FLOOR ABOVE
1'-8"
178 SQ FT
18'-4" REBUILD DRYWALL SOFFIT TO CONCEAL DUCT WORK
28'
24'-2"
INSTALL COLUMN AROUND LOAD BEARING WALL ABOVE EXISTING STEEL POST
BEDROOM
8X15.5 POST
32'-10 1/2"
13'-5" INSTALL COLUMN AROUND EXISTING STEEL POST
KEEP AND REUSE WATER HEATER
BATH
2'-8"
7'-0 1/2"
48 SQ FT
4 1/2"
E2
182 SQ FT
18'-9 1/2"
WH
14'-11"
8"
8X15.5 POST
5 TON DUAL ZONE HVAC
BEDROOM
6'-7 1/2"
2'-10 5/8"
12'-2 1/2"
1'-11 3/8"
50 SQ FT
12'-2"
8'-10 1/2"
5'-2 3/8"
59 SQ FT
7'-1 7/8"
SOFFIT TO CONCEAL DUCT WORK
3'-10"
SOFFIT TO CONCEAL DUCT WORK
"
CRAWL SPACE
REMOVE
8'-3 5/8"
-4
CRAWL SPACE
4X15.5 POST
5'-0 3/8"
4X15.5 POST
3'
Elevation 2
3'-10 1/2"
8"
5'-3"
1'-3"
4X15.5 POST
8"
1' 8"
2'-2"
3'-2"
RELEASED FOR CONSTRUCTION
8"
EXISTING PLUMBING PIPE
THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/23/2018
PROPOSED FLOOR PLAN LOWER BASEMENT LEVEL SCALE: 1/4" = 1' - 0"
SHEET: 10 OF 21
678-525-2829 jennyaburger @gmail.com
JENNY BURGER
COMPUTER DRAWING TECHNICIAN
FILL RECESS WITH NON-SHRINK GROUT WHEN STEEL HAS BEEN SET
1'
W01
7'-10 3/4"
2'
12" SQUARE X 3" DEEP RECESS
10 X 10X 1/2 BASE PLATE WITH (4) - 5/8" O THREADED ROD ANCHOR BOLTS WITH MIN. 5" EMBEDMENT, ADHERE WITH SIMPSON "SET-XP" ADHESIVE
W01 W07 5068
D15
D02
D05
FOUR #4 REBAR EACH WAY
2' NEW FOOTING FOR PERIMETER OF HOUSE
BRICK VENEER 1" AIR GAP WEEP HOLES METAL FLASHING
D04
EXISTING 24"X24"X24" REINFORCED CONCRETE FOOTINGS.
CONCRETE SLAB REINFORCING STEEL AS REQUIRED VAPOR BARRIER 4" GRAVEL BASE
DRAINAGE SYSTEM
CMU Basement Foundation w/ Brick Ledge: Unfinished (print at 1"=1') CHIEF ARCHITECT, INC. MAKES NO WARRANTY THAT THESE DRAWINGS COMPLY WITH ANY BUILDING CODES AND PROVIDED TO YOU "AS IS". PLEASE REFER TO YOUR END USER SOFTWARE LICENSE AGREEMENT FOR MORE INFORMATION ABOUT THE TERMS AND CONDITIONS PURSUANT TO THESE DRAWINGS. © Chief Architect 2006
EXISTING 4" THICK REINFORCED CONCRETE SLAB FLOOR
DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION
D03
W06
8'-1"
STEEL POST
D11
W06
2x TREATED MUDSILL SILL SEAL CAST-IN-PLACE ANCHOR BOLT
EXISTING 8" THICK CMU WALL CMU FOUNDATION WALL REINFORCING STEEL AS REQUIRED CONCRETE FOOTING
STEEL POST
W06
STEEL POST
EXISTING 9.25" FLOOR JOIST
T
9 1/4"
D13
RELEASED FOR CONSTRUCTION
3/16"
THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/23/2018
HOUSE CROSS SECTION & DETAILS SCALE: 1/4" = 1' - 0"
SHEET: 11 OF 21
678-525-2829 jennyaburger @gmail.com
EXISTING ROOF PLAN
JENNY BURGER
4 : 12
4 : 12
RELEASED FOR CONSTRUCTION
4 : 12
COMPUTER DRAWING TECHNICIAN
DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION
4 : 12
4 : 12
THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/23/2018
EXISTING ROOF FRAMING PLAN EXISTING RAFTERS: 2X10 (16" O.C.) RIDGE 2X12
PROPOSED ROOF AND ROOF FRAMING PLANS SCALE: 1/4" = 1' - 0"
SHEET: 12 OF 21
678-525-2829 jennyaburger @gmail.com
EXISTING DECK FLOOR FRAMING PLAN 2X8 (16" O.C.)
JENNY BURGER
LOAD BEARING WALL
LOAD BEARING WALL ABOVE
RELEASED FOR CONSTRUCTION
COMPUTER DRAWING TECHNICIAN
EXISTING FLOOR FRAMING PLAN 2X10 (16" O.C.) FOR THE MAIN LEVEL. DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION
THE WALLS SHOWN ARE BASEMENT WALLS
THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.
REMOVE LOAD BEARING WALL INSTALL HEADER 18" LVL INTO CEILING (TRIPLE LVL)
SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/23/2018
CEILING FRAMING PLAN 2X6 (16" O.C.) MAIN LEVEL
FLOOR FRAMING PLAN & CEILING FRAMING PLAN SCALE: 1/4" = 1' - 0"
SHEET: 13 OF 21
678-525-2829 jennyaburger @gmail.com
JENNY BURGER
COMPUTER DRAWING TECHNICIAN
4X15.5 POST
RELEASED FOR CONSTRUCTION
S
S
E3
4X15.5 POST
8X15.5 POST
WH
S E2
UP
8X15.5 POST
LOAD BEARING WALL ABOVE
LOAD BEARING WALL
S1 E4
8X15.5 POST
DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION
S
S
S
4X15.5 POST
4X15.5 POST
4X15.5 POST
REF.
ALL EXTERIOR WALLS ARE LOAD BEARING
THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/23/2018
PROPOSED BASEMENTFLPL-RED LINES MAIN LEVEL SCALE: 1/4" = 1' - 0"
SHEET: 14 OF 21
678-525-2829 jennyaburger @gmail.com
JENNY BURGER
RELEASED FOR CONSTRUCTION
COMPUTER DRAWING TECHNICIAN
PROPOSED ELEVATION 1 FRONT
4 : 12 4 : 12
8'-4"
D01
9'-11"
9'-4"
W07
W07
W07
W08
W07
8" COLUMN
8" W07
W07
W07
W07
D14
GRADE
DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION
GRADE
THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/23/2018
PROPOSED ELEVATION 1 SCALE: 1/4" = 1' - 0"
SHEET: 15 OF 21
678-525-2829 jennyaburger @gmail.com
JENNY BURGER
COMPUTER DRAWING TECHNICIAN
PROPOSED ELEVATION 2 LEFT SIDE 10819VT
16'-9"
RELEASED FOR CONSTRUCTION
W03
3'
W03
7'-5"
W02
WROUGHT IRON COLUMN
4 : 12
2X8 JOIST
8'-10"
8'-3"
GRADE
ST A
U I RS
P
GRADE
PROPOSED ELEVATION 4 RIGHT SIDE
W07
W07
16'-9"
6X6 PT POST (TYP)
W04
EXISTING SUPPORT POST TO REMAIN
W04
DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION
4 : 12
D21
THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/23/2018
PROPOSED ELEVATIONS 2 LEFT SIDE & 4 RIGHT SIDE SCALE: 1/4" = 1' - 0"
SHEET: 16 OF 21
678-525-2829 jennyaburger @gmail.com
JENNY BURGER
RELEASED FOR CONSTRUCTION
COMPUTER DRAWING TECHNICIAN
SINCE THIS WINDOW IS IN THE BATHROOM, YOU MAY WANT TO ORDER A SHORTER ONE TO MATCH THE NEXT TO IT. PROPOSED ELEVATION 3 REAR
4 : 12
W05 W07
W05
W04
W01
W01
W07 D15
16'-9"
3'
6X6 PT POST (TYP) EXISTING SUPPORT POST TO REMAIN
W06
D11
W06
GRADE
DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION
W06
8'-3"
W04 W06
8'-10"
2X8 JOIST
THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/23/2018
PROPOSED ELEVATION 3 REAR SCALE: 1/4" = 1' - 0"
SHEET: 17 OF 21
678-525-2829 jennyaburger @gmail.com
JENNY BURGER
D11
W06
W06
W04 W06
D16
D05
DOES THIS SPACE NEED A DOOR?
D21
Number D01 D02 D03 D04 D05 D11 D16 D21
Label Qty 3068 1 2868 1 2068 2 2868 2 2668 1 3068 1 3968 1 CONFIRMX68 1
Number W04 W06
Label Qty 3032DH 3 3046DH 4
LOAD BEARING WALL ABOVE
D04
Height 80 " 80 " 80 " 80 " 80 " 80 " 80 " 80 "
Door Schedule Description MECHANICAL ROOM DOOR NEW STORAGE ROOM DOOR CLOSET DOOR BEDROOM DOOR BATHROOM DOOR BACK DOOR TEMPERED GLASS NEW DOUBLE CRAWLSPACE DOOR SLIDING BASEMENT DOOR TEMPERED GLASS
Header 2x6x41" (2) 2x6x37" (2) 2x6x29" (2) 2x6x37" (2) 2x6x35" (2) 2x6x41" (2) 2x6x50" (2) 2x10x98" (2)
Thickness 1 3/4" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/4" 1 3/8" 1 3/4"
Comments
WITH LOCK CONFIRM DIMENSIONS TEMERED GLASS
W04
3068
D03
Width 36 " 32 " 24 " 32 " 30 " 36 " 45 " 93 "
D04
LOAD BEARING WALL
D03
Size 3068 L IN 2868 R IN 2068 R IN 2868 R IN 2668 L IN 3068 R EX 3968 L/R IN 7968 R EX
W04 D01 D02 Window Schedule Size Width 3032DH 36 " 3046DH 36 "
Height 38 " 54 "
Description Double Hung Double Hung
Header Comments 2x6x40" (2) 2x6x40" (2)
DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION
W06
RELEASED FOR CONSTRUCTION
COMPUTER DRAWING TECHNICIAN
THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/23/2018
DOORS/WINDOWS LOWER BASEMENT LEVEL SCALE: 1/4" = 1' - 0"
SHEET: 18 OF 21
678-525-2829 jennyaburger @gmail.com
JENNY BURGER
COMPUTER DRAWING TECHNICIAN
DOES THIS WINDOW NEED TO BE SHORTER TO MATCH THE ONE NEXT TO IT? W01
W01
D15
W07
W05
W05
W04
W07
D12
W02
D04
D03
D13 D02 W07 D07 W03 5068
D05
D06
D10
6168
DOES THIS SPACE NEED A DOOR?
RELEASED FOR CONSTRUCTION
D09
D08 W07
3068
4068
W03
D14 W07
W07
W07
W08
W07
W07
Number D01 D02 D03 D04 D05 D06 D07 D08 D09 D10 D11 D12 D13 D14 D15
Label 18080 2068 2068 2068 2868 2068 2668 2468 2668 2668 6068 2468 3068 3068 3068
Qty 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Size 18080 2068 L IN 2068 R IN 2068 R IN 2868 L IN 2068 R IN 2668 R IN 2468 L IN 2668 R IN 2668 L IN 6068 R IN 2468 R IN 3068 L EX 3068 L IN 3068 R EX
Number W01 W02 W03 W04 W05 W07 W08
Label Qty 2832DH 2 3031DH 1 3031DH 2 3046DH 1 3032DH 2 3046DH 12 5046FX 1
Size 2832DH 3031DH 3031DH 3046DH 3032DH 3046DH 5046FX
Width 32 " 36 " 36 " 36 " 36 " 36 " 60 "
Width 216 " 24 " 24 " 24 " 32 " 24 " 30 " 28 " 30 " 30 " 72 " 28 " 36 " 36 " 36 " Height 38 " 37 " 37 " 54 " 38 " 54 " 54 "
Door Schedule Height Description 96 " Garage-Garage Door CHD02 80 " BATHROOM DOOR 80 " TEMERED GLASS SHOWER DOOR 80 " MASTER BATH DOOR 80 " BEDROOM DOORS 80 " Hinged-Door P04 80 " Hinged-Door P04 80 " BEDROOM DOORS 80 " LAUNDRY DOOR 80 " BEDROOM DOORS 80 " SLIDING DOORS 80 " MASTER BATH DOOR 80 " GARAGE DOOR 80 " FRONT DOOR TEMPERED GLASS 80 " BACK Schedule DOOR TEMPERED GLASS Window Description Double Hung Double Hung NEW DBL HUNG GARAGE WINDOW Double Hung CONFIRM THIS WINDOW HEIGHT. Double Hung Double Hung Fixed Glass
Header 2x12x224" (2) 2x6x29" (2) 2x6x29" (2) 2x6x29" (2) 2x6x37" (2) 2x6x29" (2) 2x6x35" (2) 2x6x33" (2) 2x6x35" (2) 2x6x35" (2) 2x10x77" (2) 2x6x33" (2) 2x6x41" (2) 2x6x41" (2) 2x6x41" (2)
Thickness 1 3/4" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/4" 1 3/4" 1 3/4"
W07
W07
W07
Comments
DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION
D01
THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.
Header Comments 2x6x36" (2) 2x6x40" (2) 2x6x40" (2) 2x6x40" (2) 2x6x40" (2) 2x6x40" (2) 2x8x64" (2)
SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/23/2018
DOOR/WINDOWS MAIN LEVEL SCALE: 1/4" = 1' - 0"
SHEET: 19 OF 21
678-525-2829 jennyaburger @gmail.com
JENNY BURGER
RELEASED FOR CONSTRUCTION
COMPUTER DRAWING TECHNICIAN
WP
GFCI GFCI
CW
GFCI
DW
C
GFCI
GD
TUB SHOWER EXHAUST FAN CAN
GFCI 3 3
R
R
R
R
R
GFCI
R
R
R
R
C
R
3
GFCI
GFCI
R
3 3 3
R
R R
R
R EXHAUST FAN CAN
GFCI
C
R
GFCI 3
SD
R
SD
R
R
3
T
3DM
SD
3
DM 3DM
R
R
R
ATTIC ACCESS
R
R
VENT
R
R
R
CENTER FAN WITH WINDOW
R
SD
R
R
3
C C 3DM
WP
ELECTRICAL SCHEDULE CONFIRM CABLE JACK LOCATIONS NUMBER QTY ATTACHED TO DESCRIPTION COMMENTS E01 2 WALL PORCH SCONCE E02 1 WALL SPOTLIGHT 2 MOTION SENSOR E03 5 CEILING CEILING FAN WITH LIGHT E04 2 CEILING STAIRWELL LIGHTS E05 3 WALL VANITY SCONCE E06 1 CEILING MASTER CLOSET LIGHT E07 2 CEILING VAPOR SHOWER LIGHT E08 1 CEILING CLOSET LIGHT E09 1 WALL CLOTHES DRYER E10 1 WALL CLOTHES WASHER E11 1 WALL DISHWASHER E12 1 CEILING NICHE' LIGHT E14 1 WALL REFRIGERATOR E15 1 WALL GARBAGE DISPOSAL E16 10 FLOOR GFCI E17 4 CEILING SMOKE DETECTOR E18 1 CEILING DINING ROOM LIGHT E21 3 CEILING EXHAUST FAN CAN LONG SURFACE MOUNTED E22 3 CEILING FLUORESCENT LIGHT [96W9D] E23 2 CEILING BANKER'S PENDANT E24 1 WALL THERMOSTAT E25 5 WALL CABLE JACK E26 28 WALL SINGLE POLE E27 3 WALL THREE WAY (SLIDING DIMMER) E28 1 WALL SINGLE POLE (SLIDING DIMMER) E29 20 CEILING RECESSED DOWN LIGHT 6 E30 10 WALL THREE WAY E31 5 UNDER CABINET LIGHT E32 2 WALL 220V WEATHERPROOF E33 39 WALL DUPLEX
DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION
CD
THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/23/2018
LIGHTING ELECTRICAL PLAN MAIN LEVEL SCALE: 1/4" = 1' - 0"
SHEET: 20 OF 21
678-525-2829 jennyaburger @gmail.com
JENNY BURGER
RELEASED FOR CONSTRUCTION
COMPUTER DRAWING TECHNICIAN
WP
EP
WP 3DM GFCI
R
R
R
R
R
R
R
R
R
R
R
C
R C
R
C
C
EXHAUST FAN CAN
WH
3
LOAD BEARING WALL ABOVE 3
3DM
SD
R
SD
R
R
R
LOAD BEARING WALL
3
R
R
R
T 3
R
SD
R
R
REF.
R
R
SD
C
DM
DM
C
C
ELECTRICAL SCHEDULE CONFIRM CABLE JACK LOCATIONS NUMBER QTY ATTACHED TO DESCRIPTION COMMENTS E01 1 WALL ELECTRICAL PANEL E02 2 WALL EXTERIOR SCONCE E03 1 CEILING EXHAST FAN CAN E04 1 WALL VANITY SCONCE E05 1 WALL REFRIGERATOR E06 4 CEILING SMOKE DETECTOR E07 1 FLOOR GFCI E08 2 CEILING CEILING FAN WITH LIGHT E09 2 CEILING CLOSET LIGHT LONG SURFACE MOUNTED E10 4 CEILING FLUORESCENT LIGHT [72W6 3/4D] E11 1 CEILING RECESSED VAPOR LIGHT E13 7 WALL CABLE JACK E14 14 WALL SINGLE POLE E15 4 WALL THREE WAY E16 20 CEILING RECESSED DOWN LIGHT 6 E18 2 FLOOR 220V E19 3 CEILING BAR PENDANTS E20 2 WALL THREE WAY (SLIDING DIMMER) E21 2 WALL SINGLE POLE (SLIDING DIMMER) E22 2 UNDER CABINET LIGHT E23 2 WALL 220V WEATHERPROOF E24 31 WALL DUPLEX E25 1 WALL THERMOSTAT
DETACHED SINGLE FAMILY WOOD FRAME TWO STORY INTERIOR RENOVATION
TUB SHOWER
THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/23/2018
LIGHTING ELECTRICAL PLAN BASEMENT LEVEL SCALE: 1/4" = 1' - 0"
SHEET: 21 OF 21