100+ CHILLERS IN STOCK!

WITH DELIVERY AS EARLY AS ONE WEEK!

Refrigerant: R-454B

Stock Features:

QTC2

15-50 Tons

Air-Cooled Scroll Chiller

QTC3

40-230 Tons

Air-Cooled Scroll Chiller

QTC4

150-275 Tons

Air-Cooled Screw Chiller

Brazed plate heat exchanger

BAS communications (BACnet®, Modbus, N2)

Service isolation valves

High ambient kit (up to 125°F)

Low ambient operation (down to 0°F)

Hot-gas bypass

Single point non-fused disconnect

Stock Voltages: 208/3/60 and 460/3/60

Control transformer

Flow switch

Pre-coated condenser coils

Full louver panels

Neoprene isolators

Freeze protection (down to -20°F)

Refrigerant: R-454B

Stock Features:

Brazed plate heat exchanger

Microchannel condenser

BAS communications (BACnet®, Modbus, N2)

Service isolation valves

High ambient kit (up to 125°F)

Low ambient operation (down to 0°F)

Hot-gas bypass

Single point non-fused disconnect

Stock Voltages: 208/3/60 and 460/3/60

Refrigerant: R-513A

Stock Features:

Variable speed drive screw compressor

Hybrid falling-film evaporator

Microchannel condenser

Ambient operation from 0°F to 131°F

Capacity turndown to 10% load

Single point non-fused disconnect

Stock Voltages: 460/3/60

Control transformer

Flow switch

Low sound fans with VSD control

Wire / louver panels

Neoprene isolators

Freeze protection (down to -20°F)

Optional epoxy coated condenser coils (on select models)

Control transformer

Actuated suction service isolation valves with filter

dryer service valves

Water box heaters (freeze protection to -20°F)

Low sound fans with VSD control

Wire / louver panels

Neoprene isolators

Flow switch

PARTS & SUPPLIES

A24-inch,insulatedHVACsystemservicetransition designedfor24"furnace-to-coilapplications, enhancingaccessforcleaningandinspection

RS-DF19843

RS-DF19844

RS-DF19846

TheRectorSealRSH-50VRMKitisa comprehensive,NEMA3R-rated,120/240V single-phase,all-in-onesurgeprotectivedevice (SPD)andvoltagemonitordesignedtoprotect HVACequipmentfromsurges,brownouts,and over/undervoltage

Anadvanced,single-phaselinevoltage monitorwithabankofsurgearrestersfor addedprotectionagainstbrownouts, lightningstrikes,poweroutages&recoveries, startupoflargerequipment,powergrid faults,shortcircuits&more

RSH-50 VRM KIT

21073

JB-DV-22N

HANDHELD DIGITAL VACUUM GAUGE 20-9000 MC

254 24

JB-DV-22W

WIRELESS MICRON GAUGE W/ REPLACEABLE SENSOR

610 00

JB-DM4-ZW

DIGITAL MANIFOLD, BLUETOOTH, 4V ZEPPELIN

71807

NAV-NRP8DI

VACUUM PUMP 8

CFM DC DIGITAL CONTROL

42749

JB-LD-5000

PROWLER HAND HELD LEAK DETECTOR

27555

JB-DS-20000

ATLAS REFRIGERANT CHARGING SCALE, 220LB

190 NAV-N2D72

FLEX72 MANIFOLD GAUGE DISPLAY A2L

46867

#NAV-NP7DP2

VACUUM PUMP, 7 CFM, 2-STAGE, A2L

Peerless® Residential Gas Boilers

Stay Healthy This Flu Season with RGF!

Patented PHI-Cell® Technology

The indoor air quality in your home or office can be five times more polluted than outdoor air, primarily because indoor air is not properly sanitized. There are added contaminants that are simply not filtered out of the air, but instead accumulate over time in our modern, tightly sealed homes. This happens because bacteria, viruses, mold spores, and other toxins are too small to be captured by passive traditional air filters, and some can even pass through a HEPA filter. So, since you spend up to 90% of your time indoors, it's important to consider the impact these pollutants can have on your long-term health