Outdoor Product Catalogue
2021
tungsram.com
The benefits of LED
Join us in the new world of LED
• Increased sense of comfort and security • Streets and car parks are better illuminated • Enhanced CCTV through better facial recognition • Improved road safety - faster responses • Up to 70% higher energy efficiency • Longer life and reduced maintenance • Enhanced control/ dimming capabilities
LED Outdoor solutions deliver a light closer to natural daylight than the traditional lamps of the past. The latest LED lighting solutions provide an ideal upgrade path for public bodies looking to reduce energy costs and environmental impact. LED can make striking aesthetic improvements to landscapes and cityscapes.
• Colours are more vivid and more real in public areas • Better light control, less light pollution
10 Road & street 12 Inlumino (S, M, L, L+, XL) lighting 24 SMIx 2S 28 SMIx 32 Piko 36 SLBt 40 SMBt
Decorative & 46 Navona pedestrian lighting 50 Nobila
44
54 Camila
58 Area & Canopy 60 ALIx lighting 64 AMIx 68 AHIx
72 Tunnel 74 TLBt lighting 74 TMBt 78 THBt
www.tungsram.com
Order logics
88
Light distributions and optics Outdoor lighting
Product overview Whether it’s traffic on the road or people on footpaths, in public areas or visiting shops and restaurants, effective outdoor lighting means greater visibility, which in turn helps to maximise public safety and sense of security, and breathe new life back into cities. Outdoor lighting has other benefits too, including the delivery of dramatic aesthetic benefits and a major savings in energy costs. We have pioneered the development of efficient LED luminaires that have transformed the outdoor environment and enhanced the night time experience for millions.
Outdoor lighting
Lumen output characteristics
High performance area lighting is designed to ensure that the light is aimed directly where it’s needed while also delivering optimum performance in terms of luminance, uniformity and glare.
4 Lumen output
BBB
CCC
DDD
EEE
FFF
GGG
JJJ
B, B2, B5, R, S
C, C5
E, E2, E5
D
F
G2, F5
M3 to M6 and C Classes for road and street lighting.
The LED lighting is used everywhere from residential streets to highways, creating a bright white light that improves safety through improved visibility, while also reducing energy consumption and associated costs.
LED tunnel lighting fixtures combine excellent light quality with high levels of energy efficiency and reliability to deliver a safe and easy-to-maintain solution for tunnels, underpasses and industrial areas.
AAA
For C, P and S Classes, wide residential street lighting for improved face recognition and safety.
Light distributions and optics
Outdoor lighting
Lumen output characteristics
For C Classes - Pedestrian crosswalks, P Classes improved backlight for sidewalks. P, P5
X5
Z5
Asymmetrical distribution for P Classes - Area, Square and Park lighting.
Camila Post Top
AFC, AWC, AW
AF
CE-Nobila
AWD, SWD, SWF
SFC, SWC
CC
AE
SA, SB, SC, SD, SE
Y5
Symmetrical distribution for P Classes - Area, Square and Park lighting.
Symmetrical and asymmetrical distributions for Canopy lighting.
Symmetrical distributions for Tunnel lighting.
6
Lumen output
ANC, AN
Road & street lighting Outdoor lighting
Product overview
Decorative & pedestrian lighting
Canopy & Area lighting
Tunnel lighting
8 Outdoor range
Product overview
Inlumino (S,M,L,L+,XL)
SMIx 2S
SMIx
Wattage (W): 29 - 540 CCT (K): 2700, 3000, 4000, 5000 Lumen (lm): 4 000 - 75 000 IP: IP66 IK: IK09
Wattage (W): 20 - 100 CCT (K): 3000, 4000, 5000 Lumen (lm): 3 000 - 13 500 IP: IP66 IK: IK08
Wattage (W): 35 - 160 CCT (K): 3000, 4000, 5000 Lumen (lm): 5 000 - 22 000 IP: IP66 IK: IK08
Piko
SLBt
SMBt
Wattage (W): 12 - 28 CCT (K): 3000,4000, 5000 Lumen (lm): 1 500 - 3 600 IP: IP66 IK: IK08
Wattage (W): 15 - 70 CCT (K): 2700, 3000, 4000 Lumen (lm): 1 200 - 8 200 IP: IP66 IK: IK09
Wattage (W): 50 - 160 CCT (K): 3000, 4000 Lumen (lm): 6 400 - 18 700 IP: IP66 IK: IK09
Navona
Nobila
Camila
Wattage (W): 20 - 70 CCT (K): 2700, 3000, 4000 Lumen (lm): 1 700 - 7 600 IP: IP66 IK: IK08
Wattage (W): 20 - 90 CCT (K): 3000, 4000 Lumen (lm): 2 700 - 10 600 IP: IP66 IK: IK08
Wattage (W): 25 - 75 CCT (K): 2700, 3000, 4000 Lumen (lm): 3 050 - 9 070 IP: IP66 IK: IK09
ALIx
AMIx
AHIx
Wattage (W): 32 - 140 CCT (K): 3000, 4000, 5000 Lumen (lm): 3 600 - 17 600 IP: IP66 IK: IK08
Wattage (W): 55 - 150 CCT (K): 3000, 4000 Lumen (lm): 7 560 - 18 750 IP: IP65 IK: IK07
Wattage (W): 200 - 300 CCT (K): 3000, 4000, 5000 Lumen (lm): 21 000 - 37 600 IP: IP66 IK: IK08
TLBt / TMBt
THBt
Wattage (W): 32 - 175 CCT (K): 3000, 4000, 5000 Lumen (lm): 4 250 - 22 840 IP: IP66 IK: IK08
Wattage (W): 200 - 360 CCT (K): 3000, 4000, 5000 Lumen (lm): 27 000 - 50 000 IP: IP66 IK: IK09
Road & street lighting
Road and street lighting
Inlumino
Product information The new Tungsram luminaire, with its innovative and unique solutions, is an excellent choice for road and street applications.The key aspects of the lamp development are the simple and fast installation, the tool-free repair options and the diverse usage. The luminaire meets the expectations of the 21st century: sleek design, and high efficiency. Inlumino is also suitable for a variety of applications, as it can be installed as a light source or easily upgraded to an IoT data point. Take advantage of the innovation from Tungsram and optimize your outdoor lighting with the new range of Inlumino luminaires.
Application areas Pedestrian street Roadways and Highways
12 Outdoor range
Electrical
• Electronic, dimmable driver • Controls: Dali, DynaDim, CLO • ThermalGuard
Available photometric distributions:
Input voltage and frequency: 220-240V, 50-60Hz IEC protection class: Class I, Class II Driver immunity: 10kV/5kA Rated input power: 29-117W
AAA BBB CCC DDD EEE FFF GGG JJJ
Performance
Rated colour rendering index > 70 Rated correlated colour temperatures: 2700 K, 3000K, 4000K, 5000K ULOR: 0 Rated initial chromaticity co-ordinate values: • 2700K: CIE(x=0.4582, y=0.4099) 5SDCM • 3000K: CIE(x=0.4338, y=0.403) 5SDCM • 4000K: CIE(x= 0.3818, y= 0.3797) 5SDCM • 5000K: CIE(x= 0.34, y= 0.35) 5SDCM
Mounting options
Road & street lighting
• Side mounting coupler for 30-76mm diameters and -15°, -10°, -5°, 0°, +5°, +10°, +15° tilt options • Post top mounting coupler for 30-76mm diameters and -15°, -10°, -5°, 0°, +5°, +10°, +15° tilt options • Weight: 7.5 kg • Recommended mounting height: 6-15 m • Only two hand-tools required for installing the fixture • Tool-less maintenance, click and flip, twist and lock • Tool-less hinged opening and lift-off head with automatic electrical disconnect • Storage temperature from -40ºC to +85ºC • Ambient temperature from -40ºC to +50ºC
540
132 132
118
540
597 397
597 509
540
597
118
Installation and maintenance
SIZE "S"
190
• Rated luminous flux range: From 4 000 up to 15 900 lm • Rated luminaire efficacy: From 124 up to 150 lm/W • Rated median useful life and the associated rated LM factor: L80B50 > 305.000 hours • Rated useful life and the associated rated LM factor: L80B10 > 300.000 hours • Rated median useful life and the associated rated LM factor: L90B50 > 130.000 hours • Rated useful life and the associated rated LM factor: L90B10 > 128.000 hours • Rated abrupt failure value: < 10% at 100.000 hours • Photometric code: 727/559, 730/559, 740/559, 750/559 • Lumen maintenance code: 9 • Definitions and tolerances according to IEC627222-1:2014
14 Outdoor range
Dimensions (mm)
• Housing material: die-cast aluminium body and coupler, with stainless steel screws. • Optic material: Optical-grade polycarbonate • Optical cover: Tempered glass • Colour: RAL7021 • Impact Strength: IK09 (glass) / IK09 (housing) / IK08 (Shorting Cap) • Ingress protection: IP66
190 190
Structures and materials
64 different optic combinations would be available which are suitable for pedestrian streets to high traffic roads. All symmetric optic combinations are valid eg. ABA, but ABC is not.
190
Inlumino size S
Optics
132
Details
Driver feature
AAA
397 540
509
Electrical
• Electronic, dimmable driver • Controls: Dali, DynaDim, CLO • ThermalGuard
Available photometric distributions:
Input voltage and frequency: 220-240V, 50-60Hz IEC protection class: Class I, Class II Driver immunity: 10kV/5kA Rated input power: 92-187W
64 different optic combinations would be available which are suitable for pedestrian streets to high traffic roads. All symmetric optic combinations are valid eg. ABA, but ABC is not.
Dimensions (mm)
• Housing material: die-cast aluminium body and coupler, with stainless steel screws. • Optic material: Optical-grade polycarbonate • Optical cover: Tempered glass • Colour: RAL7021 • Impact Strength: IK08 (glass) / IK09 (housing) / IK08 (Shorting Cap) • Ingress protection: IP66
AAA BBB CCC DDD EEE FFF GGG JJJ
Performance
Rated colour rendering index > 70 Rated correlated colour temperatures: 2700K, 3000K, 4000K, 5000K ULOR: 0 Rated initial chromaticity co-ordinate values: • 2700K: CIE(x=0.4582, y=0.4099) 5SDCM • 3000K: CIE(x=0.4338, y=0.403) 5SDCM • 4000K: CIE(x= 0.3818, y= 0.3797) 5SDCM • 5000K: CIE(x= 0.34, y= 0.35) 5SDCM
190
• Rated luminous flux range: From 13 900 up to 25 800 lm • Rated luminaire efficacy: From 128 up to 163lm/W • Rated median useful life and the associated rated LM factor: L80B50 > 305.000 hours • Rated useful life and the associated rated LM factor: L80B10 > 300.000 hours • Rated median useful life and the associated rated LM factor: L90B50 > 130.000 hours • Rated useful life and the associated rated LM factor: L90B10 > 128.000 hours • Rated abrupt failure value: < 10% at 100.000 hours • Photometric code: 727/559, 730/559, 740/559, 750/559 • Lumen maintenance code: 9 • Definitions and tolerances according to IEC627222-1:2014
SIZE "M"
687
Mounting options
ONIMULNI 16 Outdoor range
dálascapmál itúzök sokO Road & street lighting
656
118
744
190
• Side mounting coupler for 30-76mm diameters and -15°, -10°, -5°, 0°, +5°, +10°, +15° tilt options • Post top mounting coupler for 30-76mm diameters and -15°, -10°, -5°, 0°, +5°, +10°, +15° tilt options • Weight: 9 kg • Recommended mounting height: 6-25 m • Only two hand-tools required for installing the fixture • Tool-less maintenance, click and flip, twist and lock • Tool-less hinged opening and lift-off head with automatic electrical disconnect • Storage temperature from -40ºC to +85ºC • Ambient temperature from -40ºC to +50ºC
397 744 744
132
Installation and maintenance
687 687
118
Structures and materials
190 190
Inlumino size M
Optics
132 132
Details
Driver feature
397 687
BBB
2
uh.marsgnut
656
Electrical
• Electronic, dimmable driver • Controls: Dali, DynaDim, CLO • ThermalGuard
Available photometric distributions:
Input voltage and frequency: 220-240V, 50-60Hz IEC protection class: Class I, Class II Driver immunity: 10kV/5kA Rated input power: Up to 300W
Structures and materials
64 different optic combinations would be available which are suitable for pedestrian streets to high traffic roads. All symmetric optic combinations are valid eg. ABA, but ABC is not.
Dimensions (mm)
• Housing material: die-cast aluminium body and coupler, with stainless steel screws • Optic material: Optical-grade polycarbonate • Optical cover: Tempered glass • Colour: RAL7021 • Impact Strength: IK09 (glass) / IK09 (housing) / IK08 (Shorting Cap) • Ingress protection: IP66
AAA BBB CCC DDD EEE FFF GGG JJJ
Performance
Rated colour rendering index > 70 Rated correlated colour temperatures: 2700K, 3000K, 4000K, 5000K ULOR: 0 Rated initial chromaticity co-ordinate values: • 2700K: CIE(x=0.4582, y=0.4099) 5SDCM • 3000K: CIE(x=0.4338, y=0.403) 5SDCM • 4000K: CIE(x= 0.3818, y= 0.3797) 5SDCM • 5000K: CIE(x= 0.34, y= 0.35) 5SDCM
• Rated luminous flux range: from 24 800 to 40 900 lm • Rated luminaire efficacy: from 130 up to 152lm/W • Rated median useful life and the associated rated LM factor: L80B50 > 290.000 hours • Rated useful life and the associated rated LM fac tor: L80B10 > 287.000 hours • Rated median useful life and the associated rated LM factor: L90B50 > 125.000 hours • Rated useful life and the associated rated LM factor: L90B10 > 123.000 hours • Rated abrupt failure value: < 10% at 100.000 hours • Photometric code: 727/559, 730/559, 740/559, 750/559 • Lumen maintenance code: 9 • Definitions and tolerances according to IEC62722-2-1:2014
SIZE "L"
196
Inlumino size L
Optics
786
139
Details
Driver feature
843 755
Installation and maintenance
18 Outdoor range
Road & street lighting
• Side mounting coupler for 30-60mm diameters and -15°, -10°, -5°, 0° tilt options • Post top mounting coupler for 30-60mm diameters and 15°, 10°, 5°, 0° tilt options • Weight: 12.5 kg • Recommended mounting height: 6-25 m • Only two hand-tools required for installing the fixture • Tool-less maintenance, click and flip, twist and lock • Tool-less hinged opening and lift-off head with automatic electrical disconnect • Storage temperature from -40ºC to +85ºC • Ambient temperature from -40ºC to +50ºC
127
Mounting options
407
CCC
Electrical
• Electronic, dimmable driver • Controls: 1-10V, DALI, Autonomous dimming, CLO • Thermal protection
Available photometric distributions:
Input: 90-305V, 47-63Hz Rated input: 220-240V, 50-60Hz IEC protection class: Class I Driver immunity: 10kV/5kA Rated input power: Up to 367W
Structures and materials
64 different optic combinations would be available which are suitable for pedestrian streets to high traffic roads. All symmetric optic combinations are valid eg. ABA, but ABC is not.
• Housing material: die-cast aluminium body and coupler, with stainless steel screws • Optic material: Optical-grade polycarbonate • Optical cover: Tempered glass • Colour: RAL7021 • Impact Strength: IK09 (glass) / IK09 (housing) / IK08 (Shorting Cap) • Ingress protection: IP66
AAA BBB CCC DDD EEE FFF GGG JJJ
Performance
Rated colour rendering index > 70 Rated correlated colour temperatures: 2700K, 3000K, 4000K, 5000K ULOR: 0 Rated initial chromaticity co-ordinate values: • 2700K: CIE(x=0.4582, y=0.4099) 5SDCM • 3000K: CIE(x=0.4338, y=0.403) 5SDCM • 4000K: CIE(x= 0.3818, y= 0.3797) 5SDCM • 5000K: CIE(x= 0.34, y= 0.35) 5SDCM
• Rated luminous flux range: Up to 50 000 lm • Rated luminaire efficacy: Up to 158 lm/W at 5000K • Rated median useful life and the associated rated LM factor: L90B50 > 140.000 hours, L80B50 > 330.000 hours • Rated abrupt failure value: < 10% at 100.000 hours • Photometric code: 727/559, 730/559, 740/559, 750/559 • Lumen maintenance code: 9 • Definitions and tolerances according to IEC62722-2-1:2014
Dimensions (mm)
SIZE "L+"
196
Inlumino size L+
Optics
786
139
Details
Driver feature
843 755
Installation and maintenance Mounting options
127
• Side mounting coupler for 30-76mm diameters and -15°, -10°, -5°, 0°, +5°, +10°, +15° tilt options • Post top mounting coupler for 30-76mm diameters and -15°, -10°, -5°, 0°, +5°, +10°, +15° tilt options • Weight: 13.5 kg • Recommended mounting height: 6-25 m • Only two hand-tools required for installing the fixture • Tool-less hinged opening and lift-off head with automatic electrical disconnect • Storage temperature from -40ºC to +85ºC • Ambient temperature from -40ºC to +50ºC 407
20 Outdoor range
Road & street lighting
JJJ
Details
Inlumino size XL
Driver feature
Optics
Electrical
• Electronic, dimmable driver • Controls: Dali, DynaDim, CLO • ThermalGuard
Available photometric distributions:
Input voltage and frequency: 220-240V, 50-60Hz IEC protection class: Class I Driver immunity: 10kV/5kA Rated input power: Up to 540W
Structures and materials • Housing material: die-cast aluminium body and coupler, with stainless steel screws • Optic material: Optical-grade polycarbonate • Optical cover: Tempered glass • Colour: RAL7021 • Impact Strength: IK09 (glass) / IK09 (housing) / IK08 • Ingress protection: IP66
Performance • Rated luminous flux range: Up to 75 000 lm • Rated luminaire efficacy: Up to 145lm/W at 4000K • Rated median useful life and the associated rated LM factor: L80B50 > 100.000 hours • Rated useful life and the associated rated LM fac tor: L80B10 > 287.000 hours • Rated abrupt failure value: < 10% at 100.000 hours • Photometric code: 730/559, 740/559, 750/559 • Lumen maintenance code: 9 • Definitions and tolerances according to IEC62722-2-1:2014
64 different optic combinations would be available which are suitable for pedestrian streets to high traffic roads. All symmetric optic combinations are valid eg. ABA, but ABC is not.
Dimensions (mm)
AAA BBB CCC DDD EEE FFF GGG JJJ
SIZE "XL"
Rated colour rendering index > 70 Rated correlated colour temperatures: 3000K, 4000K, 5000K ULOR: 0 Rated initial chromaticity co-ordinate values: • 3000K: CIE(x=0.4338, y=0.403) 5SDCM • 4000K: CIE(x= 0.3818, y= 0.3797) 5SDCM • 5000K: CIE(x= 0.34, y= 0.35) 5SDCM
913
161
161
Mounting options
410 994
865
994
161
994
142
410
913
Road & street lighting
913
142
Installation and maintenance
22 Outdoor range
242
242
913
• Side mounting coupler for 30-76mm diameters and -15°, -10°, -5°, 0°, +5°, +10°, +15° tilt options • Post top mounting coupler for 30-76mm diameters and -15°, -10°, -5°, 0°, +5°, +10°, +15° tilt options • Weight: 18 kg • Recommended mounting height: 18-25 m • Only two hand-tools required for installing the fixture • Tool-less maintenance, click and flip, twist and lock • Tool-less hinged opening and lift-off head with automatic electrical disconnect 242 • Storage temperature from -40ºC to +85ºC • Ambient temperature from -40ºC to +50ºC
242
GGG
865
Road and street lighting
SMIx 2S
Product information SMIx 2S offers an optimal solution for street lighting. Taking advantage of Tungsram’s proprietary modular refractive optic system, a wide range of light distributions can be achieved. The optimized mechanical design provides simple installation, adjustability, and reliability.
Application areas Pedestrian street Roadways and Highways
24 Outdoor range
26 Outdoor range
Details
SMIx 2S
Driver feature
Optics
Electrical
• Electronic, ddimmable driver: Dali, DynaDim, CLO, Analog
Available photometric distributions:
Input voltage and frequency: 220-240V, 50-60Hz Class I Surge immunity: 10kV/5kA Rated input power: 20W to 100W Power factor ≥ 0,9
Structures and materials • Housing material: die-cast aluminium body and coupler, with stainless steel screws • Optic material: Optical-grade polycarbonate • Optical cover: Tempered glass • Colour: RAL7035 • Impact Strength: IK08 (glass) / IK09 (housing) / IK08 (Shorting Cap) • Ingress protection: IP66
Performance
• C: optimized for wide high traffic M class roads • E: optimized for narrow P class roads • F: optimized for wide P class roads • Q: optimized for narrow high traffic M class roads
Dimensions (mm)
Rated colour rendering index >70 Rated correlated colour temperatures*: 3000K, 4000K, 5000K ULOR: 0
Rated initial chromaticity co-ordinate values
365 368
• 3000K: CIE(x=0.43, y=0.403) 5SDCM • 4000K: CIE(x= 0.38, y= 0.38) 5SDCM • 5000K: CIE(x= 0.34, y= 0.35) 5SDCM
• Rated luminous flux range: from 3 000 to 13 500 lm • Rated luminaire efficacy: : from 135 to 150 lm/W • Rated median useful life and the associated rated LM factor L80B50: > 121.000 hours • Rated useful life and the associated rated LM factor: L80B10 > 115.000 hours • Rated median useful life and the associated rated LM factor: L90B50 > 54.000 hours • Rated useful life and the associated rated LM factor: L90B10 > 50.000 hours • Rated abrupt failure value: < 10% at 100.000 hours • Abrupt light output degradation (C) < 10 at 100.000 hours • Photometric code: 730/559, 740/559, 750/559 • Lumen maintenance code: 9
154 365
503
96
Installation and maintenance
568
Mounting options
26 Outdoor range
Road & street lighting
• Side mounting with coupler for 42-60 diameters and -15°, -10°, -5°, 0°, 5°, 10°, 15° tilt options • Post top mounting with coupler for 42-60 diameters and -15°, -10°, -5°, 0°, 5°, 10°, 15° tilt options • Side mounting with coupler for 30-48 diameters and -15°, -10°, -5°, 0° tilt options • Post top mounting with coupler for 30-48 diameters and 0°, 5°, 10°, 15° tilt options • Weight: 5 kg • Recommended mounting height: 4 - 15m • Only two hand-tools required for installing the fixture • Storage temperature up to 85ºC. • Ambient temperature from -40ºC to +50ºC
154
95
445 445
499
154
95 95
499 499
C: optimized for wide high traffic M class roads
Road and street lighting
SMIx
Product information SMIx offers an optimal solution for street lighting. Modular refractive optic system, a wide range of light distributions can be achieved. The optimized mechanical design provides simple installation, adjustability and reliability.
Application areas Residental Road and street Motorways
28 Outdoor range
30 Outdoor range
Details
Driver feature
Optics
Electrical
• Electronic, dimmable (DALI) driver with autonomous dimming: 35-160W
Available photometric distributions:
Input voltage and frequency: 220-240V, 50-60Hz Class I: standard, Class II: on request Surge protection: 10 kV Rated input power: 35W to 160W
Structures and materials
SMIx
• Housing material: die-cast aluminium body and UV stawal-grade polycarbonate • Optical cover: Tempered glass • Colour: RAL7035 • Impact Strength: IK08 on optical parts, IK09 on housing and coupler • All materials used in this product are WEEE and ROHS compatible. • Ingress protection: IP66
Performance
• C: optimized for high traffic M class roads • E: optimized for narrow S class roads • F: optimized for wide S class roads
Rated colour rendering index >70 Rated correlated colour temperatures: 3000K, 4000K, 5000K S/P rating for : 3000K: 1.24, 4000K: 1.47, 5000K:1.71 ULOR (Upward Light Output Ratio): 0
• 3000K: CIE(x=0.43, y=0.403) 5SDCM • 4000K: CIE(x= 0.38, y= 0.38) 5SDCM • 5000K: CIE(x= 0.34, y= 0.35) 5SDCM
154
503
Installation and maintenance
96
Mounting options
568
• Side-mounting coupler for 30-60mm diameters and -15°, -10°, -5°, 0° tilt options • Post top mounting coupler for 30-60mm diameters and 15°, 10°, 5°, 0° tilt options • Weight: 7,5 kg • Recommended mounting height: 4 - 15m • Only two hand-tools required for installing the fixture • Storage temperature up to 85ºC. • Ambient temperature from -40ºC to 50ºC
C: optimized for high traffic M class roads
Road & street lighting
368
Rated initial chromaticity co-ordinate values
• Rated luminous flux range: from 5 000 to 22 000 lm • Rated luminaire efficacy: Up to 153 lm/W at 4000K • Rated median useful life and the associated rated LM factor L80B50: > 121.000 hours • Rated abrupt failure value: 3.12 %* • Photometric code: 730/559, 740/559, 750/559 • Lumen maintenance code: 9 • Rated ambient temperature (tq) related to performance for a luminaire: 25°C
30 Outdoor range
Dimensions (mm)
Road and street lighting
Piko
Product information Tungsram’s LED road and street fixture, the PIKO, which makes the advantages of outdoor LED lighting available for everyone, even those on tight budgets. Designed to replace 11-36 W CFL and 35-70 W HID fixtures, the PIKO is a great LED solution for minor roads, residential streets and other public spaces where modest levels of illumination are required.
Application areas Street & residential road lighting Car park
Pedestrian street
Public area 32 Outdoor range
Piko
Optics
Electrical
• Electronic, non-dimmable driver
Available photometric distributions:
Structures and materials
• C: optimized for low traffic M class roads • E: optimized for narrow P class roads • F: optimized for wide P class roads
Input voltage and frequency: 220-240V, 50Hz IEC Safety Classification: Class I, Class II Driver surge immunity: 6kV Rated input power: 12W to 28W
• Housing material: die-cast aluminium body, corrosion resistant screws • Color: RAL7035 • Optical cover: tempered glass • Impact strength: IK08 • Ingress protection: IP66
Performance • Rated luminous flux range: from 1 500 to 3 600 lm • Rated luminaire efficacy: Up to 140 lm/W • Photometric code: 730/559, 740/559, 750/559 • Rated median useful life and the associated rated LM factor: L80B50 > 110.000 hours • Rated median useful life and the associated rated LM factor: L80B10 > 110.000 hours • Rated median useful life and the associated rated LM factor: L90B50 > 54.000 hours • Rated abrupt failure value: 10% at 50.000 hours • Lumen maintenance code: 9 • Rated ambient temperature (tq) related to performance for a luminaire: 25°C
Rated colour rendering index: >70 Rated correlated colour temperatures: 3000K, 4000K, 5000K S/P rating for: 3000K - 1.33, 4000K - 1.56, 5000K - 1.78 ULOR: 0
Rated initial chromaticity co-ordinate values 3000K - CIE(x=0.43, y=0.403) 5SDCM 4000K - CIE(x= 0.38, y= 0.38) 5SDCM 5000K - CIE(x= 0.34, y= 0.35) 5SDCM
372
140
Installation and maintenance Mounting options • Side mount ø35mm-60mm • Recommended mounting height: 4-8m • Weight: 2 kg • Only two hand-tools required for installing the fixture • Storage temperature up to 85ºC. • Ambient temperature from -40ºC to +35ºC
F: optimized for wide P class roads
34 Outdoor range
Road & street lighting
Dimensions (mm)
61
Details
Driver feature
Road and street lighting
SLBt
Product information Introducing our latest LED road and street fixture, the SLBt, which makes the advantages of outdoor LED lighting available for everyone, even those on tight budgets. Designed to replace 35-100W HID and 24-36W CFL fixtures, the SLBt is a great LED solution for minor roads, residential streets and other public spaces where modest levels of illumination is required.
Application areas Residental Road and street Motorways
36 Outdoor range
Car park
Details
SLBt
Driver feature
Optics
Electrical
• Electronic, dimmable DALI driver with autonomous dimming: 15-70W. • Constant Light Output (optional)
Available photometric distributions:
Input voltage and frequency: 220-240V, 50-60Hz Class I: standard, Class II: on request Surge protection: 10 kV Rated input power: 15W to 70W
Structures and materials • Housing material: die-cast aluminium body, corrosion resistant screws and brackets • Optic material: coated polycarbonate or aluminium • Colour: RAL7035 • Optical cover: UV stabilized polycarbonate • All materials used in this product are WEEE and ROHS compatible. • Impact strength: IK09 • Ingress protection: IP66
Performance • Rated luminous flux range: from 1 200 to 8 200 lm at 4000K • Rated luminaire efficacy: up to 122 lm/W at 4000K. • Photometric code: 727/559 , 730/559, 740/559 • Rated median useful life and the associated rated LM factor L80B50: > 218.000 hours • Rated abrupt failure value: 11.5 % • Lumen maintenance code: 9 • Rated ambient temperature (tq) related to Performance for a luminaire: 25°C
• Narrow Asymmetric – medium (B, B2, B5) • Asymmetric – short (C, C5) • Asymmetric forward – very short (D) • Asymmetric – medium (E, E2, E5) • Forward asymmetric – medium (F, F5, G2) • Narrow asymmetric – short (N) • Narrow asymmetric with backlight – short (P, P5) • Narrow asymmetric – medium (R) • Narrow asymmetric – medium (S) • Asymmetric – short (T) • Asymmetric – medium (U) • Pedestrian cross walk (X5, Z5) • Symmetric – medium (Y5)
Rated initial chromaticity co-ordinate values • 3000K: CIE(x=0.4578, y=0.4101) 5SDCM • 4000K: CIE(x=0.43, y=0.403) 5SDCM • 5000K: CIE(x=0.38, y=0.38) 5SDCM
Mounting options
38 Outdoor range
Road & street lighting
347
Rated colour rendering index:>70 Rated correlated colour temperatures*: 2700K, 3000K, 4000K S/P rating for : 2700K: 1.09 , 3000K: 1.33, 4000K: 1.56 ULOR (Upward Light Output Ratio): 0
Installation and maintenance • Side mount bracket ø42mm-60mm • Post top bracket ø48mm-76mm • Universal coupler side ø35mm-76mm • Universal coupler post ø35mm-76mm • Bracket can be adjusted: 0°, +5° (with accessories -5° also available) • Universal Coupler can be adjusted -15°,-10°, -5°, 0°, +5°,+10°, +15° by 5°degree steps • Recommended mounting height: 4-15m • Weight: 5 kg • Only two hand-tools required for installing the fixture • Storage temperature up to 85ºC. • Ambient temperature from -40ºC to 35ºC
Dimensions (mm)
Asymmetric – short
386
72
Road and street lighting
SMBt
Product information Our LED roadway lighting fixture makes all the advantages of LED lighting available for a wide audience. Designed to replace 35-150W HID fixtures, SMBt is a great LED solution for minor roads, residential streets and other public spaces where modest level of illumination is required.
Application areas Residental Road and street Motorways
40 Outdoor range
Car park
42 Outdoor range
Details
Driver feature
Optics
Electrical
• Electronic, dimmable (DALI) driver with autonomous dimming: 50W-160W • Minimum dimming level 20W
Available photometric distributions:
Input voltage and frequency: 220-240V, 50-60Hz Class I: standard, Class II: on request Surge protection: 10 kV Rated input power: 52W to 158W
• Constant Light Output (optional)
SMBt
Structures and materials • Housing material: die-cast aluminium body, corrosion resistant screws and brackets • Optic material: coated polycarbonate or aluminium • Optical cover: glass • Colour: RAL7035 • All materials used in this product are WEEE and ROHS compatible. • Impact strength: IK08
• Narrow Asymmetric – medium (B, B2, B5) • Asymmetric – short (C, C5) • Asymmetric forward – very short (D) • Asymmetric – medium (E, E2, E5) • Forward asymmetric – medium (F, F5) • Narrow asymmetric – short (N) • Narrow asymmetric with backlight – short (P, P5) • Asymmetric – short (T) • Pedestrian cross walk (X5, Z5) • Symmetric - (Y5) • Asymmetric – medium (U)
• Ingress protection: IP66
Rated colour rendering index:>70 Rated correlated colour temperatures: 3000K, 4000K S/P rating for : 3000K: 1.33, 4000K: 1.56 ULOR (Upward Light Output Ratio): 0
Performance
Rated initial chromaticity co-ordinate values
• Rated luminous flux range: from 6 400 to 18 700 lm at 4000K • Rated luminaire efficacy: Up to 146 lm/W at 4000K. • Photometric code: 730/559, 740/559 • Rated median useful life and the associated rated LM factor L80B50: > 102.000 hours • Rated abrupt failure value: 11.5 % • Lumen maintenance code: 9 • Rated ambient temperature (tq) related to performance for a luminaire: 25°C
103
566
Mounting options
42 Outdoor range
Road & street lighting
352
• 3000K: CIE(x=0.43, y=0.403) 5SDCM • 4000K: CIE(x= 0.38, y= 0.38) 5SDCM
Installation and maintenance • Side mount bracket ø42mm-60mm • Post top bracket ø42mm-76mm • Universal coupler side ø35mm-76mm • Universal coupler post ø35mm-76mm • Bracket can be adjusted: -5°, 0°, +5° • Universal Coupler can be adjusted -15°,-10°, -5°, 0°, +5°,+10°, +15° by 5°degree steps • Weight: 7,5 kg • Storage temperature up to 85ºC. • Ambient temperature from -40ºC to +50ºC up to 140W +40ºC up to 160W
Dimensions (mm)
Narrow Asymmetric – medium
Decorative & Pedestrian lighting
Decorative & Pedestrian lighting
Navona
Product information Navona is a LED solution to replace traditional fixtures in parks, pedestrian areas, city centers. Timeless design incorporates the aesthetic necessities with the optimal optical distribution, providing several lumen packages with symmetrical and asymmetrical distribution and a power range from 16W to 72W to meet a wide range of lighting scenarios. Navona offers a major increase in both vertical and horizontal uniformity. Combined with the high chromatic reproduction contributed by LED technology (white light), this uniform quality facilitates face recognition and visual comfort. Its advanced optical design enables the light to be directed specifically where it is needed.
Application areas Residental City centres (road classifications: from P2 to P6) 46 Outdoor range
Parks
Electrical
• Electronic, programmable & dimmable (DALI and 0-10V). • Controllable driver with astronomical clock availability. • Controls system inputs: Analog, DALI, Dynadim
Available photometric distributions:
Input voltage and frequency: 220-240V, 50-60Hz IEC Protection Class: Class I, Class II Surge protection: 10 kV Rated input power: 20W to 70W
Rated colour rendering index >70 Rated correlated colour temperatures: 2700K, 3000K, 4000K ULOR (Upward Light Output Ratio): 0 S/P rating for : 2700K: 1.09, 3000K: 1.24, 4000K: 1.47
Rated initial chromaticity co-ordinate values • 2700K: CIE(x=0.4578, y=0.4101) 5SDCM • 3000K: CIE(x=0.43, y=0.403) 5SDCM • 4000K: CIE(x=0.38, y=0.38) 5SDCM
*
Performance 542
• Rated luminous flux range: 1 700 to 7 600 lm • Rated luminaire efficacy: Up to 118 lm/W • Rated median useful life and the associated rated LM factor L80B50: > 200.000 hours • Rated abrupt failure value: 13.2 %* • Photometric code: 727/559 , 730/559, 740/559 • Lumen maintenance code: 9 • Rated ambient temperature (tq) related to performance for a luminaire: 25°C
Mounting options
Decoratove and Pedestrian
*
Ø76
Ø60
Ø48
500
108
Installation and maintenance
48 Outdoor range
**
213 654
• 1- and 2-arm through 42-48, 60, 76 mm standard post top mounting. Side mounting through 60 mm diameter pole. • Weight: 11,2 kg • Recommended mounting height: 4-6 m • Ambient operating temperature: -30°C to 50°C • Storage temperature: up to 85°C
584*/589**/594***
• Housing material: in three pieces (upper-housing, lowerhousing and arm with coupler), all made from die-cast aluminium with a polyester powder paint finish and oven cured. • Surface finish: polyester powder coat • Colour: RAL9007 • Optical cover:flat tempered glass • All materials used in this product are WEEE and ROHS compatible. • Impact strength: IK08 • Ingress protection: IP66
Dimensions (mm)
476*/481**/486***
Structures and materials
• Asymmetric Forward Clear (AFC) • Asymmetric Wide Clear (AWC) • Asymmetric Narrow Clear (ANC) • Asymmetric Wide Diffuser (AWD) • Symmetric Wide Clear (SWC) • Symmetric Wide Diffuser (SWD) • Symmetric Forward Clear (SFC)
584*/589**/594***
Navona
Optics
476*/481**/486***
Details
Driver feature
Symmetric Wide, Forward
Decorative & Pedestrian lighting
Nobila
Product information Introducing Tungsram’s latest LED decorative fixture, the Nobila, which has the advantage of aesthetic outdoor luminaires with great performance. Designed to replace 35-100 W HID and 24-36 W CFL fixtures, the Nobila is a great LED solution for roads, where heritage style is needed.
Application areas Pedestrian street Car park
50 Outdoor range
Street & residential road lighting
Electrical
• Electronic, dimmable driver: Dali, CLO and dynadim from 20-90W • minimum dimming level 5,5 W
Available photometric distributions:
Input voltage and frequency: 220-240V, 50-60Hz Class I, Class II Surge protection: 10kV Rated input power: 21W to 86W
Performance • Rated luminous flux range: from from 2 600 to 9 700lm at 4000K • Rated luminaire efficacy: Up to 135lm/W at 4000K • Photometric code: 730/559, 740/559 • Rated median useful life and the associated rated LM factor L80B50: > 100.000 hours • Rated abrupt failure value: <10% (100.000 hours) • Lumen maintenance code: 9 • Rated ambient temperature (tq) related to performance for a luminaire: 25°C
Rated colour rendering index: >70 Rated correlated colour temperatures: 3000K, 4000K S/P rating for: 3000K - 1.33, 4000K - 1.56 ULOR: 0 3000K - CIE(x=0.43, y=0.403) 5SDCM 4000K - CIE(x= 0.38, y= 0.38) 5SDCM
*
P76: Ø60-76mm **
P60: Ø48-60mm ***
P48: Ø45-48mm
Mounting options • Post top coupler ø48mm-76mm • Recommended mounting height: 4-15m • Weight: 6,5 kg • Only two hand-tools required for installing the fixture • Storage temperature up to 85ºC. • Ambient temperature from -40ºC to +50ºC
Circular E
Decoratove and Pedestrian
354
Rated initial chromaticity co-ordinate values
Installation and maintenance
52 Outdoor range
Dimensions (mm)
586/591/596
362
• Housing material: die-cast aluminium body, corrosion resistant screws • Color: RAL9005 or any RAL color • Optic material: coated polycarbonate • Optical cover: UV stabilized polycarbonate • Gear Tray material: galvanized steel • Impact strength: IK08 • Ingress protection: IP66
• AC - asymetric C • AE - asymetric E • AF - asymetric F • AH - asymetric H • SC - symmetric C • SE - symmetric E • SF - symmetric F • CC - circular C • CE - circular E • CF - circular F
561.5* / 566.5** / 571.5***
Structures and materials
• C: optimized for high traffic M class roads • E: optimized for narrow P class roads • F: optimized for wide P class roads • H: optimized for M class roads, low mounting height
362
Nobila
Optics
360
Details
Driver feature
Decorative & Pedestrian lighting
Camila
Product information Introducing Tungsram’s latest LED decorative fixture, the Camila, which has the advantage of aesthetic outdoor luminaires with great performance. The Camila is a great LED solution for roads, where heritage style is needed.
Application areas
54 Outdoor range
Pedestrian street / Parks
Car park
Dimensions (mm) Ø 460 Ø 460
Rated initial chromaticity co-ordinate values
Performance • Rated luminous flux range: from 3 050 to 9 070 lm at 4000K • Rated luminaire efficacy: Up to 130lm/W at 4000K • Photometric code: 730/559, 740/559, 727/559 • Rated median useful life and the associated rated LM factor L80B50: > 100.000 hours • Rated abrupt failure 0,3% at 50.000 hours • Lumen maintenance code: 9 • Rated ambient temperature (tq) related to perfor- mance for a luminaire: 25°C
80
Ø 460
612
Ø 75
• Post top coupler ø66mm • Side mount: ø48-60 mm (pole) • Recommended mounting height: 4-15m • Weight: 9,5 kg • Only two hand-tools required for installing the fixture • Storage temperature up to 85ºC. • Ambient temperature from -40ºC to +50ºC • Length of precable: 3m
168
80
Ø 83.2
612
Mounting options
Ø 460
Ø 83.2 Ø 75
Post-top asymmetric
Decoratove and Pedestrian
Ø 66
Ø 76
Ø 460 Ø 460
Installation and maintenance
56 Outdoor range
529.8
2700K - CIE(x=0.4578, y=0,4101) 5SDCM 3000K - CIE(x=0.43, y=0.403) 5SDCM 4000K - CIE(x= 0.38, y= 0.38) 5SDCM
78 78
529.8
• Housing material: die-cast aluminium body • Color: RAL9006 • Optic material: coated polycarbonate • Optical cover: Tempered safety glass (5mm) • Impact strength: IK09 • Ingress protection: IP66
Rated colour rendering index: >80 Rated correlated colour temperatures:2700K, 3000K, 4000K S/P rating: 2700K - 1.239, 3000K - 1.373, 4000K - 1.674 ULOR: 0
168
Structures and materials
Input voltage and frequency: 100-277 V, 50-60Hz IEC protection class: Class I Extra surge protection (standard): 10kV Rated input power: 25-75W
• A: asymmetric • S: symmetric
468.7
Camila
Available photometric distributions:
468.7
Details
Electrical
80
• Electronic, dimmable driver with DALI control or static • Minimum dimming level 0 W
Optics
80
Driver feature
Canopy & Area lighting Area & Canopy lighting
Area lighting
ALIx
Product information ALIx LED outdoor luminaire delivers outstanding features, style and attractive form factor. This latest design offers excellent efficacy even at higher lumen outputs to meet a wide range of area lighting needs.Using reflective optic technology, Tungsram offers superior horizontal and vertical illuminance with high uniformity, while minimizing glare. This system delivers unusually low perceived glare when viewed from beneath. ALIx provides reduced energy consumption, combined with a long rated life that virtually eliminates ongoing maintenance expenses, enabling significant operating cost benefits over the life of the fixture.
Application areas Car park Industrial & logistic Shopping centres Pedestrian crossings 60 Outdoor range
62 Outdoor range
Electrical
• Electronic, dimmable (DALI) driver with autonomous dimming: 32-140W • Minimum dimming level 15W • DynaDimmer • Constant Light Output
Available photometric distributions:
Input voltage and frequency: 220-240V, 50-60Hz Class I, Class II Surge protection: 10 kV Rated input power: 31W to 142W
Structures and materials • Housing material: die-cast aluminium body, corrosion resistant screws and brackets • Optic material: highly reflective aluminium coated plastic • Optical cover: tempered glass • Colour: RAL9007 • All materials used in this product are WEEE and ROHS compatible. • Impact strength: IK08 • Ingress protection: IP65
Performance
• Asymmetric Forward (AF) • Asymmetric Wide (AW) • Asymmetric Narrow (AN) • Asymmetric Extra Wide Flood (AEF) • Asymmetric Forward Throw Narrow* (AFN) • Symmetrical Wide Flood (SWF) • Symmetrical Narrow Spot (SNS)
Dimensions (mm) 157
*AFN optics only available with Powers 100W &140W
Rated colour rendering index:>70 at 4000K Rated correlated colour temperatures: 3000K, 4000K,5000K S/P rating for : 3000K: 1.24, 4000K: 1.47, 5000K:1.71 ULOR (Upward Light Output Ratio): 0
316
ALIx
Optics
422,2
Rated initial chromaticity co-ordinate values • 3000K: CIE(x=0.43, y=0.403) 5SDCM • 4000K: CIE(x= 0.38, y= 0.38) 5SDCM • 5000K: CIE(x= 0.34, y= 0.35) 5SDCM
• Rated luminous flux range: from 3 600 to 17 600 lm at 5000K • Rated luminaire efficacy: Up to 140lm/W at 5000K. • Photometric code: 730/559, 740/559, 750/559 • Rated median useful life and the associated rated LM factor L80B50 > 131.000 hours • Rated abrupt failure value: 2.5 % • Lumen maintenance code: 9 • Rated ambient temperature (tq) related to performance for a luminaire: 25°C
385
Details
Driver feature
103,3
114,7
505,9
Installation and maintenance • Coupler ø60mm for side-mount or post-top • Adjustable bracket (between -85° and 85° from horizontal) • Recommended mounting height: 8-15m • Tool-less driver maintenance • Storage temperature up to 85ºC. • Operating temperature from -40ºC to 50ºC • Weight: 9 kg 62 Outdoor range
Area
79,5
Mounting options
Asymmetric Narrow
Canopy lighting
AMIx
Product information The AMIx, Tungsram’s latest LED canopy fixture, provides a flexible and rapid installation solution for petrol stations, high bays, low bays, parking garages, industrial areas and other area lighting application areas. The AMIx is ideally suited both for replacing traditional fixtures such as HID luminaires and for new installations.
Application areas Parking garages Petrol station Industrial High bay Floodlighting
64 Outdoor range
66 Outdoor range
Electrical
• Electronic, dimmable driver • 150W with DALI control • Power factor > 0,97
Available photometric distributions:
Input voltage and frequency: 220-240V, 50-60Hz IEC Protection Class: Class I Surge Immunity: 10kV Rated input power: 55W to 146W
Structures and materials • Housing material: die-cast and sheet metal aluminium body,stainless steel screws and brackets • Surface finish: polyester powder coat • Colour: RAL9003 • Optical cover: tempered low-iron glass • All materials used in this product are WEEE and ROHS compatible • Impact strength: IK07 • Ingress protection: IP65
Performance • Rated luminous flux range: 7560 to 18,750 lm • Rated luminaire efficacy: Up to 146 lm/W • Rated median useful life and the associated rated LM factor L80B50: > 120.000 hours • Rated useful life and the associated rated LM factor L90B10: > 105.000 hours • Rated abrupt failure value: <10% at 100.000 hours • Photometric code: 730/559, 740/559 • Lumen maintenance code: 9 • Rated ambient temperature (tq) related to performance for a luminaire: 25°C
• AC - asymmetric C • AE - asymmetric E • AF - asymmetric F • SC - symmetric C • SE - symmetric E • SF - symmetric F • CC - circular C • CE - circular E • CF - circular F
Rated initial chromaticity co-ordinate values • 3000K: CIE(x= 0.43, y= 0.403) 5SDCM • 4000K: CIE(x= 0.38, y= 0.38) 5SDCM S/P rating for 3000K: 1,33; 4000K: 1,56
Mounting options • Bezel, surface mount and flood • Weight: 9kg • Recommended mounting height: 4-6 m • Ambient operating temperature: -40°C to +50°C • Storage temperature: up to 85°C
Canopy
350
Rated colour rendering index >70 Rated correlated colour temperatures*: 3000K, 4000K ULOR: 0
Installation and maintenance
66 Outdoor range
Dimensions (mm)
140
AMIx
Optics
350
Details
Driver feature
Asymmetric
Area lighting
AHIx
Product information AHIx luminaire offers an optimal LED lighting solution for high lumen package applications. Tried and tested reflective optic technology, combined with the effective thermal management, excellent light efficiency can be maintained throughout the whole lifetime of the luminaire, even under extreme thermal conditions. A wide range of different light distributions makes this luminaire versatile and flexible for numerous application areas. AHIx is a perfect choice for high power LED lighting applications where optical flexibility and reliability are critical.
Application areas Industrial & Maintenance Logistical areas: airports, ports, trains Car park Sport 68 Outdoor range
70 Outdoor range
Driver feature
Optics
Electrical
• Electronic dimmable Dali driver • Minimum dimming level: 30%
Available photometric distributions:
Input voltage and frequency: 220-240V, 50-60Hz IEC Protection Class: Class I, Class II Surge protection: 10 kV Rated input power: 200W to 300W
Structures and materials • Housing material: die-cast and sheet metal aluminium body,stainless steel screws and brackets • Surface finish: polyester powder coat • Colour: RAL9007 • Optical cover: tempered low-iron glass • All materials used in this product are WEEE and ROHS compatible • Impact strength: IK08 • Ingress protection: IP66
Rated colour rendering index >70 Rated correlated colour temperatures: 3000K, 4000K, 5000K ULOR (Upward Light Output Ratio): 0
Rated initial chromaticity co-ordinate values
Installation and maintenance
• 3000K: CIE(x=0.43, y=0.403) 5SDCM • 4000K: CIE(x= 0.38, y= 0.38) 5SDCM • 5000K: CIE(x= 0.34, y= 0.35) 5SDCM
67
438
AHIx Integrated Luminiare (ST and SP Accessory Options)
Asymmetric Wide
Mounting options
750
Area
492
• Adjustable stirrup • Weight: 15kg • Recommended mounting height: 10-40 m • Ambient operating temperature: -40°C to 50°C • Storage temperature: up to 85°C
70 Outdoor range
574
209
• Rated luminous flux range: 21 000 to 37 600 lm at 5000K • Rated luminaire efficacy: Up to 133lm/W • Rated median useful life and the associated rated LM factor L80B50: > 110.000 hours • Rated abrupt failure value: 3.12 %* • Photometric code: 740/559, 750/559 • Lumen maintenance code: 9 • Rated ambient temperature (tq) related to performance for a luminaire: 25°C
AHIx Remote Driver Luminiare (RST and RSP Accessory Options)
69
Performance
Dimensions (mm)
66.5
AHIx
460
Details
• Asymmetric Forward (AF) • Asymmetric Wide (AW) • Asymmetric Narrow (AN) • Asymmetric Extra Wide Flood (AEF) • Asymmetric Forward Throw Narrow (AFN) • Symmetric Wide Flood (SWF) • Symmetric Narrow Spot (SNS) • Symmetric Forward (SF) • Symmetric Wide (SW)
Asymmetric Forward
Tunnel lighting
Tunnel lighting
TLBt & TMBt
Product information Bring great light from Tungsram into your tunnels with the TLBt and TMBt, Tungsram’s new single and double module tunnel lighting fixtures. The TLBt & TMBt are available in a range of optical combinations for flexibility across a wide range of applications such as low and high speed tunnels, underpasses and industrial areas. Maintenance in a tunnel environment can cause a headache not only for the operators but for the users as well. Tungsram’ engineers therefore put major focus on developing a highly durable and reliable product with a long lifetime, providing an easy and rapid tool-less maintenance solution to speed up installation and reduce disruptive maintenance, as well as its costs. Safety is another important aspect regarding tunnels in which lighting has a key role. Our tunnel lighting solution can increase light quality and therefore safety through better visibility for drivers, who can react more rapidly to emergencies and other situations in tunnels, where every second matters.
Application areas
74 Outdoor range
• Industrial • Floodlight • Underpasses
Electrical
• Drivers available from 75 up to 165 Watts with dynadim, AMPdim and DALI control • Minimum dimming level: 15W for TLBt and 30W for TMBt
Available photometric distributions:
Input voltage and frequency: 220-240V, 50-60Hz Class I, Class II Surge immunity: minimum 10kV in Class I, minimum 6kV in Class II Rated input power: 33W to 176W
• Housing material: die-cast aluminium • Optical material: aluminised plastic or aluminium • Optical cover: tempered glass • Colour: RAL9005 • All materials used in this product are WEEE and ROHS compatible • Impact strength: IK08 • Ingress protection: IP66
Performance • Rated luminous flux: from 4 250 to 22 840 lm • Rated luminaire efficacy: up to 143 lm/W • Photometric code: 730/559, 740/559, 750/559 • Rated median useful life and the associated rated LM factor: L80B50 > 181.000 hours • Rated useful life and the associated rated LM factor: L90B10 > 78.000 hours (TMBt) L90B10 > 79.000 hours (TLBt) • Rated abrupt failure value: value < 10% at 100.000 hours* • Lumen maintenance code: 9 • Rated ambient temperature (tq) related to performance for a luminaire: 25°C
Rated colour rendering index:>70 Rated correlated colour temperatures*: 3000k, 4000K, 5000K S/P rating for: 3000K - 1.22, 4000K - 1.5, 5000K - 1.71 ULOR: 0
510
Rated initial chromaticity co-ordinate values • 3000K: CIE(x=0.4338, y=0.403) 5SDCM • 4000K: CIE(x= 0.3818, y= 0.3797) 5SDCM • 5000K: CIE(x= 0.34, y= 0.35) 5SDCM
150
5
Tunnel
. 15
76 Outdoor range
Symmetric Medium
.5
Mounting options
150
22
.5
15
Installation and maintenance • Two types of fixing bracket are available: short arm for ceiling mounting, and long arm for wall mounting. Additional mounting solutions are available on request. • Weight: 9 Kg • Recommended mounting height: 4-8 m • The LED light engine and driver are replaceable without the need of tools, enabling a quick and easy maintenance solution • Recommended maintenance factor for lighting design: 0.8 • Ambient temperature from -40ºC to +50ºC • Storage temperature up to 85ºC
Dimensions (mm)
316
Structures and materials
• Extra narrow Asymmetric – medium (A) • Narrow Asymmetric – medium (B, B5, AQ) • Asymmetric – short (C) • Asymmetric forward – very short (D) • Asymmetric – medium (E, E5) • Extra narrow Symmetric – medium (SA) • Narrow Symmetric – medium (SB, SB5) • Symmetric – short (SC) • Symmetric forward – very short (SD) • Symmetric – medium (SE, SE5, Y)
148
TLBt & TMBt
Optics
B1:248 B2:297
Details
Driver feature
Tunnel lighting
THBt
Product information Tungsrams’ THBt with its high efficiency and lumen package provides the required solution for tunnel lighting. The High Wattage Tunnel LED is available in a range of optical combinations for flexibility across a wide range of applications such as low and high speed tunnels, underpasses and industrial areas. Maintenance in a tunnel environment can cause a headache not only for the operators but for the users as well. Tungsram’ engineers therefore put major focus on developing a highly durable and reliable product with a long lifetime, providing an easy and rapid tool-less maintenance solution to speed up installation and reduce disruptive maintenance, as well as its costs. Safety is another important aspect regarding tunnels in which lighting has a key role. Our tunnel lighting solution can increase light quality and therefore safety through better visibility for drivers, who can react more rapidly to emergencies and other situations in tunnels, where every second matters.
Application areas
78 Outdoor range
• Underpasses • Industrial • Floodlight
Driver feature • 330 Watt driver with dynadim, AMPdim and DALI control. • Minimum dimming level: 35W
Details
THBt
Electrical
Available photometric distributions:
Input voltage and frequency: 220-240V, 50-60Hz ClassI, Class II Surge immunity: minimum 10kV Rated input power: 200W to 360W
• Extra narrow Asymmetric – medium (AA) • Narrow Asymmetric – medium (AB) • Asymmetric – short (AC) • Asymmetric – medium (AE) • Narrow Symmetric – medium (SB) • Symmetric – short (SC) • Symmetric – medium (SE)
Structures and materials • Housing material: die-cast aluminium • Optical material: polycarbonate • Optical cover: tempered glass • Colour: RAL9005 • All materials used in this product are WEEE and ROHS compatible. • Impact strength: IK09 • Ingress protection: IP66
Optics
Performance • Rated luminous flux: from 27 000 to 50 000 lm • Rated luminaire efficacy: up to 156 lm/W • Photometric code: 730/559, 740/559, 750/559 • Rated median useful life and the associated rated LM factor: L80B50 > 181.000 hours • Rated useful life and the associated rated LM factor: L90B10 > 78.000 hours • Rated abrupt failure value: value < 10% at 100.000 hours* • Lumen maintenance code: 9 • Rated ambient temperature (tq) related to performance for a luminaire: 25°C
Dimensions (mm)
Rated colour rendering index:>70 Rated correlated colour temperatures*: 3000k, 4000K, 5000K S/P rating for: 3000K - 1.22, 4000K - 1.5, 5000K - 1.71 ULOR: 0
Rated initial chromaticity co-ordinate values • 3000K: CIE(x=0.4338, y=0.403) 5SDCM • 4000K: CIE(x= 0.3818, y= 0.3797) 5SDCM • 5000K: CIE(x= 0.34, y= 0.35) 5SDCM
Installation and maintenance
80 Outdoor range
Tunnel
• Three types of fixing bracket are available: short arm for ceiling mounting, long arm for wall mounting and remote driver placement. • Additional mounting solutions are available on request. • Weight: 22 Kg • Recommended mounting height: 4-8 m • The driver is replaceable without the need of tools, enabling a quick and easy maintenance solution • Recommended maintenance factor for lighting design: 0.8 • Ambient temperature from -40°C to +50°C (200W to 280W: Ta=50°C; 281W to 360W, Ta=35°C) • Storage temperature up to 85ºC
504
Mounting options
Symmetric Medium
82 Outdoor range
Tunnel lighting overview
What you need to know about tunnel lighting
Tunnel lighting
Interior zone
Good tunnel lighting takes care of good visibility conditions for the road users, this requires lighting levels that are matched with the adaptation level of the users’ eyes. As this adaptation level gradually changes while travelling through the tunnel, for lighting purposes the tunnel can be divided lengthwise into five zones: the access, threshold, transition, interior and exit zone. The decision whether a tunnel or underpass has to be lit during the day depends on • the length of the tunnel • the visibility of the exit • the amount of natural light in the tunnel • the traffic density.
In the interior zone the required lighting levels are related to the structure and size of the tunnel, the speed of the traffic and the traffic density.
The access zone The access zone is not a part of the tunnel itself, but the approach road immediately before the tunnel entrance. The drivers’ vision will have to adapt to the conditions in the tunnel. It is very important that the drivers should be able to see any obstacles or any kind of danger even from this access zone, so that they can react on time.
Lsurrounding
Exit zone
82 Tunnel lighting overview
Lroad
In the exit zone the tunnel lighting has to prepare the eye of the drivers for the outside conditions. Even though visual adaptation from low to high level takes place instantaneously, but there are other reasons for installing an increased lighting level in the exit zone: • to make following cars more visible in the rear-view mirror of a car leaving the tunnel • to prepare the driver in case of an emergency when exiting the tunnel.
Emergency lighting Emergency lighting is usually part of the lighting system and guarantees minimal light when the power supply is interrupted.
The threshold zone
Tunnel Lighting should provide the driver with the same safety and comfort as driving on an open road. There should be a smooth lighting transition from approaching, transiting and exiting the tunnel, to help the drivers see all obstacles in the environment and the behaviour of other road users.
Lsky
20º cone
L20
road
surrounding
(See CIE 88)
Recommended threshold/access zone luminance ratios Stopping distance (m)
Symmetrical lighting system Lth/ L20
Counter-beam lighting system Lth/ L20
60 100 160
0.05 0.06 0.10
0.04 0.05 0.07
Recommended interior zone luminances (cd/m2) Stopping distance (m) 60 100 160
The required luminance level in the first section of the threshold zone of the tunnel, which length is equal to the safe stopping distance, will proportionally reduce the amount of light and energy needed. In the second half of the threshold zone the luminance level is decreased rapidly to 40 % of the initial level.
sky
Traffic density <100 veh/h 0.05 0.06 0.10
100<veh/h<1000
>1000 veh/h 0.04 0.05 0.07
Save stopping distance Entrance L20
%L20
Ltrans = Lth (1.9 + t) -1.4
Exit Lth Lexit Ltr
Transition zone In the transition zone the lighting level is gradually reduced further. The reduction speed is related to the adaptation speed of the eyes but the steps of the reduction should not exceed a ratio of 3:1.
Access zone
Transition zones Time
Exit zone
Transition zone
treshold zone
threshold zone
Lint
Interior zone
84 Outdoor range
Reflective
Reflective vs Refractive
Refractive
Great utilisation factor
Primary target Wasted light
Minimized visibility to LED light source, creating non-pixilated appearance to driver’s field of view
Reflective Strengths The perceived direct glare of refractive optics is greater than reflective optics.
Application efficiency Colour dispersion Longevity
APPLICATION EFFICIENCY UNIFORMITY
MANUFACTURING
Refractive Strengths Thermal behavior Luminaire size
COLOR DISPERSION
MAINTENANCE
Like for like Uniformity Maintenance Manufacturing
84 Great utilisation factor
Visibility to every LED, creating a pixilated appearance and increased glare to driver’s field of view
LONGEVITY
LUMINAIRE SIZE THERMAL BEHAVIOR
Reflective Refractive
Lighting Designer software
With the plugin you will have the chance to find the products you need quickly and create a digital design of your ideas with Dialux. It's simple and efficient – just like the professional lighting solutions.
Dialux Offline plugin
What are the benefits of Dialux? • Simple, effective and professional light planning • Latest “state of the art” software, always available free of charge • Fits perfectly into designers' existing workflow. • Energy evaluation is simple and quick • Colored light scenes with LED or other luminaires
You can carry out simple and professional light planning by using the Dialux plug-in. Save time through a new user experience. The plugin is filled with plenty of additional solutions like customizable collections, inspirational materials and a completely up-to-date product catalogue.
Key plug-in features • Fast and efficient • Up to date product info • Custom collection • Inspiration material • New interface • Industry relevant news
You can find all our indoor and outdoor luminaires and the related technical files in our eCatalogue as part of our website – www.tungsram.com . 86 Dialux plugin
Order logics Name Gen.
Nominal Lumen (lm)
Optics
CCT (K)
Option Accessories list
IEC Protection Classes
Control
Precabling
Mounting
Color
NNo control
Nominal Name Gen. Lumen (lm)
Optics
CCT (K)
Option Accessories list
Control
IEC Protection Classes
Precabling
Mounting
Color
INL
NNo control
INS
1
4000 6000 8000 10000 12000 14000 16000
AAA BBB CCC DDD EEE FFF GGG
730 3000K 70 CRI
S
740 4000K 70 CRI
N E
750 5000K 70 CRI
NO No Accessory
DDALI external
FU Fuse
Yxx Dynadim
SP Extra surge protection
C1 Class I
NL No control+ CLO
C2 Class II
FS Fuse + extra surge protection
DL DALI+CLO
NP No precabling PC Precabling with XX meters
48 - Universal 30-48mm 60 - Universal 42-60mm
1
25000 27500 30000 32500 35000 37500 40000
AAA BBB CCC DDD EEE FFF GGG
730 3000K 70 CRI
NO No Accessory
DDALI external
FU Fuse
Yxx Dynadim
SP Extra surge protection
C1 Class I
NL No control+ CLO
C2 Class II
FS Fuse + extra surge protection
DL DALI+CLO
S
740 4000K 70 CRI
N E
750 5000K 70 CRI
R7021 Rxxxx
NP No precabling Pxx Precabling with XX meters
48 - Universal 30-48mm 60 - Universal 42-60mm
R7021 Rxxxx
YLxx Dynadim+ CLO
Example: INL1-25000AAA740-SNOD-C1NP60
YLxx Dynadim+ CLO
Example: INS1-8000EEE750-NSPD-C1PC60 Name Gen.
Nominal Lumen Optics (lm)
CCT (K)
Option Accessories list
Control
IEC Protection Classes
Precabling
Mounting
Color Customer
NNo control
Nominal Name Gen. Lumen (lm)
Optics
CCT (K)
Option Accessories list
Control
IEC Protection Classes
Precabling
Mounting
Color 727 2700K 70 CRI
NNo control
INM
1
14000 16000 18000 20000 22000 24000 26000
AAA BBB CCC DDD EEE FFF GGG
730 3000K 70 CRI 740 4000K 70 CRI 750 5000K 70 CRI
S N E
NO No Accessory
DDALI external
FU Fuse
Yxx Dynadim
SP Extra surge protection
C1 Class I
NL No control+ CLO
C2 Class II
FS Fuse + extra surge protection
DL DALI+CLO YLxx Dynadim+ CLO
NP No precabling PC Precabling with XX meters
AAnalog 1-10V Control
48 - Universal 30-48mm 60 - Universal 42-60mm
R7021 Rxxxx
INL+
1
40000 42500 45000 47500 50000
AAA BBB CCC DDD EEE FFF GGG JJJ
DDALI external
730 NO 3000K 70 SNo CRI Standard Accessory 740 4000K 70 CRI
NNEMA
Yxx Autonomous dimming
SP NL Extra surge No control + CLO protection
750 5000K 70 CRI
Example: INM1-22000CCC740-SSPD-C1PC60
ALxx 1-10V + CLO DL DALI+CLO YLxx Autonomous dimming+ CLO
Example: INL+1-40000AAA740-NSPD-C1NU60
C1 Class I
NU48 - Universal No 30-48mm precabling U60 - Universal R7021 Pxx 42-60mm Rxxxx Precabling with XX U76 - Universal meters 60-76mm
XX
Name
Gen.
Nominal Lumen (lm)
Optics
Option list
CCT (K)
Accessories
Control
IEC Protection Classes
Precabling
Mounting
NNo precabling
U48 - Universal 30-48mm
Color
Customer
R7021 Rxxxx
XX
NNo control AAA
INXL
1
50000
BBB
55000
CCC
60000
DDD
65000
EEE
70000
FFF
75000
GGG JJJ
730 3000K 70 CRI 740 4000K 70 CRI 750 5000K 70 CRI
DDALI external
SStandard NNEMA EECO
NO No Accessory SP Extra surge protection
Yxx Dynadim NL No control+ CLO
C1 Class I
DL DALI+CLO
U60 - Universal Pxx 42-60mm Precabling with XX U76 - Universal meters 60-76mm
YLxx Dynadim+ CLO
Example: INXL1-75000AAA740-NSPD-C1NU60
Name
Gen. Optics
Power (W)
CCT (K)
Control
Accessories
IEC protection classes
Precabling
Mounting
Color
PXPre cabling with X meters
U48 Universal coupler 30-48 mm
R7035
Customer
Nx No control CCC
DDALI
CEC
A1-10 V
CFC CQC
Yx DynaDIM
ECE EEE 30 3000
EFE
SMIx
2S
EQE FCF FEF FFF FQF QCQ QEQ QFQ QQQ
20 100
40 4000 50 5000
YIx Autonomous Dimming
ST - Standard, 10kV Surge immunity (built-in the driver, EN 61547)
NL No control + CLO
SP - Enhanced Surge Voltage Protection
NILx No control + CLO, non NFC driver DL DALI + CLO AL 1-10 V + CLO YLx DynaDIM + CLO YILx Autonomous Dimming + CLO
Example: SMIx/2S/CFC/65/40/D/ST/C1/P1/U60
LS - NEMA socket with Shorting Cap LSP - NEMA socket with Shorting Cap + Enhanced Surge Voltage Protection
C1 - Class I
PCXPre cabling with X meters and connector
U60 Universal coupler 42-60 mm
Rxxxx
XXX
Name
Gen. Optics
Power (W)
CCT (K)
Control N - No control
SMIx
2
CFC CEC CCC FCF FEF EEE ECE EFE FFF
35 50 65 80 100 120 140 160
ST - 6kV Surge immunity (built-in the driver)
D - DALI 30 - 3000K 40 - 4000K 50 - 5000K
Yxx - DynaDIM NL - No control + CLO
IEC protection classes
Accessories
Precabling
Mounting
Name
Gen.
Front Power Optics Glass (W)
3
B C D E F P R S T N U B2 E2 B5 C5 E5 F5 P5 Y5
PXU48 Pre cabling Universal coupler with X meters 30-48 mm PCXC2 - Class II U60 Pre cabling Universal coupler with X meters 50-60 mm and connector
SP - Enhanced surge voltage protection10kV/5kA C1 - Class I
DL - DALI + CLO YLxx - DynaDIM + CLO
LSP - NEMA socket with Shorting Cap + Enhanced Surge Voltage Protection 10kV/5kA
SMBt
F-Flat Glass
Example: SMIx/2/FFF/140/40/D/ST/C1/PC3/U60/R7035
Name
PIKO
Gen. Optics
1
Power (W)
CCT (K)
3 - 3000K
12 18 21 28
C E F
Control
4 - 4000K
NNo control
5 - 5000K
IEC Accessories Protection Classes ST Standard FFuse
C1 Class1 C2 Class II
Precabling
Mounting
Px Precabled with x meters
S35 Coupler 3540mm
PCx Precabled with connector with x meters
S60 Coupler 4060mm
SLBt
Gen.
3
Front Glass
Optics
F-Flat Glass
B C D E F N P R S T U B2 B5 C5 E2 E5 F5 G2 P5 X5 Y5 Z5
Power (W)
CCT (K)
Control
Accessories
IEC Protection Classes
Name
IEC Protection Classes
Accessories
Precabling
Mounting
S60 Side mount bracket 42-60mm
50 65 80 95 105 120 140 160
ST - Standard type
D - Dali
M3 - Minicell 35lux
Yxx - Dynadim
30-3000 40-4000
N - No control
NL - No control with CLO
P76 Post top bracket 48-76mm
SP - Extra surge protection
C1 - Class I
F - Fuse
C2 - Class II
DL - Dali with CLO
LS - 7 pin NEMA socket
YLxx - DynaDim with CLO
SR - Smart ready connector
NNo precabling
U35 Universal coupler with insert 35-42 mm
PXXU50 Precabling with XX Universal coupler meters with insert 42-55 mm U60 Universal coupler with insert 50-60 mm U76 Universal coupler 55-76 mm
Gen.
Optics
Power (W)
CCT (K)
Control
Accessories
IEC Protection Classes
Precabling
Arm Type
Coupler
N - No control
NAVONA Precabling
Control
Example: SMBT/3/F/B/75/40/N/ST/C1/N/S60
Example: PIKO/1/C/21/4/N/ST/C1/P1/S60
Name
CCT (K)
AFC AWC ANC AWD SWC SWD SFC
3
Mounting
20 29 30 40 50 60 70
D - Dali 27-2700
Yxx - Dynadim
30-3000
NL - No control + CLO
40-4000
ST Standard type 10kv Surge immunity (built in driver)
DL - Dali + CLO
LS 7 pin NEMA Socket
NC1 - Class I No precabling PXC2 - Class II Precabling with XX meters
11 arm
48 42- 48 mm
22 arms
60 54-60mm
Sside
7070-76mm
YLxx - Dynadim + CLO ST Standard type
15 20 30 35 40 50 55 70
NNo control
M3 Minicell 35lux
S60 Side mount bracket 42-60mm
D - DALI
SP Extra Surge protection
P76 Post top bracket 48-76mm
F - Fuse
U35 Universal coupler 35-42 mm
272700 Yxx - DynaDim 303000
NLNo control with CLO
404000
DLDali with CLO
Example: SLBT/3/F/B/20/40/N/ST/C1/N/S60
YLxx DynaDim with CLO
LS 7 pin NEMA socket LSP 7 pin NEMA socket + Surge protection SR Smart ready connector
C1 - Class I
NNo precabling
PXXC2 - Class II Precabling with XX meters
Example: NA/3/AFC/20/30/D/ST/C1/N/1/60
Name
Gen.
U76 Universal coupler 55-76 mm
Power (W)
CCT (K)
Control
Accessories
IEC Protection Classes
Precabling
Mounting
N - No control
U50 Universal coupler 42-55 mm U60 Universal coupler 50-60 mm
Optics
NBL
1
CC CE CF AC AE AF SC SE SF
20 30 40 50 60 70 80 90
D - DALI 33000 44000
Yxx - DynaDIM NL - No control + CLO DL - DALI + CLO YLxx - DynaDIM + CLO
Example: NOBILA/1/CC/40/3/N/ST/1/P1/P60
ST Standard version LS 7-pin NEMA socket
1Class I 2Class II
Px Precabled with x meters
P60 Ø4860mm P76 Ø6076mm
Brand
Family
Camila
TU
Generations
G1 Generation 1
Optic
AAsymmetric SSymmetric
Power
25W 50W 75W
CRI + CCT
Control
Accessories
Color
Shipment
Name
Front Glass
Gen.
D - Dali S - Static
840 80 CRI + 4000K
ST Standard Type
P1 Post Top 1 50-64mm
Power (W)
Optics
DS Direct Shipment
Rxxxx
AEF - Asymmetric Extra Wide Flood
AHIx
P2 Post Top 2 60-75mm
F-Flat Glass
2
200 250 285 300
AFN - Asymmetric Forward Throw Narrow SWF - Symmetrical Wide Flood SNS - Symmetrical Narrow Spot
SF - Symmetrial Forward
Name
Gen.
Optics
3
F-Flat Glass
Control
AF - Asymmetric Forward
NNo control
AW - Asymmetric Wide
DDALI external
AN - Asymmetric Narrow
ALIX
CCT (K)
AEF - Asymmetric Extra Wide Flood AFN - Asymmetric Forward Throw Narrow
32 50 70 100 140
3-3000 4-4000 5-5000
IEC Accessories Protection Precabling Mounting Special Options Classes
DL DALI +CLO
SWF - Symmetrical Wide Flood
Name Gen.
Front glass
Sp Enhanced surge protection LS 7 pin NEMA socket with SP
1 - Class I
NNo precabling
PXX2 - Class II Precabling with XX meters
C60mm Coupler BBracket
ST - Standard version A2 cable gland cable entries
TLBt
AMIx
3
Front Glass
F-Flat Glass
Optics
AC - asymmetric C AE - asymmetric E AF - asymmetric F SC - symmetric C SE - symmetric E SF - symmetric F CC - circular C CE - circular E CF - circular F
Example: AMIx/3/F/S25/100/740/D/C1/N/B
Power (W)
C1 Class I C2 Class II
NNo precabling
B1 Bracket (Long) B2 Bracket (Short)
PXPrecabling B3 with XX Bracket (Coupler meters Ø60mm)
Power (W)
Optics
CCT [K]
IEC Accessories protection Precabling class
Control
Costumer
Mounting
4
CCT (K)
F
740-4000
AMPxxx -
30 - 3000 Output current amplitude 32-90 35W-90W
dimming
Wxxx - LineSwitch
40 - 4000
SP 10kV Extra Surge protection
Yxxx - DynaDIM NL - No control + CLO
50 - 5000
ST10kV Surge immunity (built-in the driver)
C1 Class 1 C2 Class 2
Nwithout precabling Px Precabled with x m
B1Short bracket for ceiling mounting B2Long bracket for wall mounting
MCx Mounted Connector
XXX
YLxxx - DynaDIM + CLO
Control
IEC Protection Precabling Mounting Classes
N- No precabling 730-3000
A B C D E Y B5 E5
WLxxx - LineSwitch + CLO
NNo control D - DALI
C1 - Class I
PPrecabling
PCPrecabling Nwith quick no connector mounting kit
F
AA - (Asym) AB - (Asym) AC - (Asym) AD - (Asym) AE - (Asym) 30 - 3000 AQ - (Asym) AB5 - (Asym) 130 - 175 AE5 - (Asym) 40 - 4000 130W-175W SA - (Sym) SB - (Sym) 50 - 5000 SC - (Sym) SD - (Sym) SE - (Sym) SB5 - (Sym)) SE5 - (Sym)
NNo control D - DALI AMPxxx Output current amplitude dimming Wxxx - LineSwitch Yxxx - DynaDIM NL - No control + CLO DL - DALI + CLO
ST10kV Surge immunity (built-in the driver) SP 10kV Extra Surge protection
C1 Class 1 C2 Class 2
Nwithout precabling Px Precabled with x m
B1Short bracket for ceiling mounting
MCx Mounted Connector
B2Long bracket for wall mounting
XXX
WLxxx - LineS witch + CLO YLxxx - DynaDIM + CLO
Example: TLBt/4/F/Y/90/40/D/ST/C1/N/B1, TMBt/4/F/AA/130/40/D/ST/C1/N/B1
SM Surface Mount FL Flood-light
4
Color
BBezel 55 65 80 100 120 150
NL No control + RST 5CLO Remote Driver 5000 Luminaire, DL Driverbox DALI + separated CLO from luminaire YLxx Dynadim + CLO
DL - DALI + CLO
TMBt Gen.
44000
Yxx Dynadim
ST Standard Luminaire, Driverbox mounted on luminaire
D - DALI
ST 6kV surge protection
Example: ALIX/3/F/AEF/140/4/D/ST/1/P10/C/R9005/A
Name
Mounting
Example: AHIx/2/F/AF/200/4/D/ST/C1/N/B1
YLxx Dynadim +CLO
SNS - Symmetrical Narrow Spot
IEC Protection Precabling Classes
NNo control
YxxDynadim NL Constant Light
Accessories
DDALI
AW - Asymmetric Wide R9006
SW - Symmetrical Wide
Power (W)
Control NNo control
AN - Asymmetric Narrow
Example: TU Camila G1 A 50W 830 D ST P1 R9006
Front Glass
CCT (K)
AF - Asymmetric Forward
SE Side Entry 40-64mm
827 80 CRI + 2700K 830 80 CRI + 3000K
Mounting Options
R9003
Name
Gen.
Front glass
Optics
Nominal Power (W)
CCT [K]
Control NNo control
THBt
1
AA - (Asym) AB - (Asym) AC - (Asym) F - Flat AE - (Asym) Glass SB - (Sym) SC - (Sym) SE - (Sym)
200 240 280 320 360
3 - 3000 4 - 4000 5 - 5000
D - DALI Yxx - DynaDIM NL - No control + CLO DL - DALI + CLO YLxx - DynaDIM + CLO
Example: THBt/1/F/AC/360/4/D/ST/1/MC2/B2
IEC Accessories protection class STDriver box mounted on luminaire RST Remote driver box with 2 m connection cable
Precabling PX Precabling with X meters
C1 Class I C2 Class II
PCX Precabling with X meters and quick connector MCX Mounted Connector
Mounting
Costumer
B1 Ceiling mounting B2 Wall mounting B3 Remote driver
XXX
ABOUT TUNGSRAM At Tungsram, we see ourselves as more than just a lighting company that offers an innovative approach to lighting. We are shaping the future of urban living providing technology-driven, smart and sustainable solutions for large metropolitan areas using light as a platform. Learn more: www.tungsram.com
We in Tungsram Operations Kft. are constantly developing and improving our products. For this reason, all product descriptions in this catalogue are intended as a general guide, and we may change specifications from time to time in the interest of product development, without prior notification or public announcement. All descriptions in this publication present only general particulars of the goods to which they refer and shall not form part of any contract. Data in this guide has been obtained in controlled experimental conditions. However, Tungsram cannot accept any liability arising from the reliance on such data to the extent permitted by law. Outdoor Product Catalogue February 2021