Outdoor Product Catalogue
2019
tungsram.com
Join us in the new world of LED
The benefits of LED
• Increased sense of comfort and security • Streets and car parks are better illuminated • Enhanced CCTV through better facial recognition • Improved road safety - faster responses • Up to 70% higher energy efficiency • Longer life and reduced maintenance • Enhanced control/ dimming capabilities
LED Outdoor solutions deliver a light closer to natural daylight than the traditional lamps of the past. The latest LED lighting solutions provide an ideal upgrade path for public bodies looking to reduce energy costs and environmental impact. LED can make striking aesthetic improvements to landscapes and cityscapes.
• Colours are more vivid and more real in public areas • Better light control, less light pollution
12 Road& street 14 SLBt lighting 18 SMBt 22 SMIx 26 Piko 30 Spinella
Decorative & 36 Navona pedestrian lighting 40 Nobila
34
44 Canopy & Area 46 ALIx lighting 50 AMIx 54 AHIx
58 Tunnel 60 TLBt lighting 60 TMBt
www.tungsram.com
Order logics
68
Lighting Designer software
With the plugin you will have the chance to find the products you need quickly and create a digital design of your ideas with Dialux. It's simple and efficient – just like the professional lighting solutions.
Dialux Offline plugin
What are the benefits of Dialux? • Simple, effective and professional light planning • Latest “state of the art” software, always available free of charge • Fits perfectly into designers' existing workflow. • Energy evaluation is simple and quick • Colored light scenes with LED or other luminaires
You can carry out simple and professional light planning by using the Dialux plug-in. Save time through a new user experience. The plugin is filled with plenty of additional solutions like customizable collections, inspirational materials and a completely up-to-date product catalogue.
Key plug-in features • Fast and efficient • Up to date product info • Custom collection • Inspiration material • New interface • Industry relevant news
You can find all our indoor and outdoor luminaires and the related technical files in our eCatalogue as part of our website – www.tungsram.com . 4 Dialux plugin
Outdoor lighting
Product overview Whether it’s traffic on the road or people on footpaths, in public areas or visiting shops and restaurants, effective outdoor lighting means greater visibility, which in turn helps to maximise public safety and sense of security, and breathe new life back into cities. Outdoor lighting has other benefits too, including the delivery of dramatic aesthetic benefits and a major savings in energy costs. We have pioneered the development of efficient LED luminaires that have transformed the outdoor environment and enhanced the night time experience for millions. The LED lighting is used everywhere from residential streets to highways, creating a bright white light that improves safety through improved visibility, while also reducing energy consumption and associated costs. High performance area lighting is designed to ensure that the light is aimed directly where it’s needed while also delivering optimum performance in terms of luminance, uniformity and glare. LED tunnel lighting fixtures combine excellent light quality with high levels of energy efficiency and reliability to deliver a safe and easy-to-maintain solution for tunnels, underpasses and industrial areas.
6 Lumen output
Outdoor lighting
Lumen output characteristics
Light distributions and optics
M3 to M6 and C Classes for road and street lighting. Mounting above 6m.
CCC
EEE
FFF
B, B2, B5, R, S
C, C5
E, E2, E5
D
F
G2, F5
P5
X5
Z5
M3 to M6 and C Classes for road and street lighting. Mounting above 6m.
For C, P and S Classes, wide residential street lighting for improved face recognition and safety. Mounting below 4m.
For C Classes - Pedestrian crosswalks, P Classes improved backlight for sidewalks Mounting above 6m.
Light distributions and optics Outdoor lighting
Lumen output characteristics
For Wet Road Classes Pedestrian sidewalks, parking lanes. Mounting above 6m. N, T
U
P
AF
ANC, AN
AFC, AWC, AW
AWD, SWD, SWF
SFC, SWC
A25, A35, A55
S25, S35, S55
SA, SB, SC, SD, SE
Y5
Asymmetrical distribution for P Classes - Area, Square and Park lighting. Mounting below 6m.
Symmetrical distribution for P Classes - Area, Square and Park lighting. Mounting below 6m.
Symmetrical and asymmetrical distributions for Canopy lighting. Mounting 4-6m.
Symmetrical distributions for Tunnel lighting.
8 Lumen output
Road & street lighting Outdoor lighting
Product overview
Decorative & pedestrian lighting
SLBt
SMBt
SMIx
Wattage (W): 15 - 70 CCT (K): 2700, 3000, 4000 Lumen (lm): 1 200 - 8 200 IP: IP66 IK: IK09
Wattage (W): CCT (K): Lumen (lm): IP: IK:
Piko
Spinella
Wattage (W): 12 - 28 CCT (K): 3000,4000, 5000 Lumen (lm): 1 500 - 3 600 IP: IP66 IK: IK08
Wattage (W): 50 - 235 CCT (K): 3000, 4000, 5000 Lumen (lm): 5 500 - 26 300 IP: IP66 IK: IK09
Navona
Nobila
Wattage (W): 16 - 72 CCT (K): 2700, 3000, 4000 Lumen (lm): 1 100 - 7 400 IP: IP66 IK: IK08
Wattage (W): 20 - 90 CCT (K): 3000, 4000 Lumen (lm): 2 600 - 9 700 IP: IP66 IK: IK08
ALIx
AMIx
AHIx
Wattage (W): 32 - 140 CCT (K): 3000, 4000, 5000 Lumen (lm): 3 600 - 17 600 IP: IP66 IK: IK08
Wattage (W): 40 - 160 CCT (K): 4000, 5000 Lumen (lm): 4 600 - 18 800 IP: IP65 IK: IK08
Wattage (W): 200 - 300 CCT (K): 4000, 5000 Lumen (lm): 21 000 - 37 600 IP: IP66 IK: IK08
TLBt
TMBt
Wattage (W): 32- 90 CCT (K): 4000 Lumen (lm): 3 800 - 9 800 IP: IP66 IK: IK09
Wattage (W): 130 - 150 CCT (K): 4000 Lumen (lm): 1 4500 - 17 400 IP: IP66 IK: IK09
50 - 160 3000, 4000 6 400 - 18 700 IP66 IK09
Wattage (W): CCT (K): Lumen (lm): IP: IK:
35 - 160 3000, 4000, 5000 5 000 - 22 000 IP66 IK08
Canopy & Area lighting
Tunnel lighting
10 Outdoor range Product overview
Road & street lighting
Road and street lighting
SLBt
Product information Introducing our latest LED road and street ďŹ xture, the SLBt, which makes the advantages of outdoor LED lighting available for everyone, even those on tight budgets. Designed to replace 35-100W HID and 24-36W CFL ďŹ xtures, the SLBt is a great LED solution for minor roads, residential streets and other public spaces where modest levels of illumination is required.
Application areas Residental Road and street Motorways
14 Outdoor range
Car park
Details
SLBt
Driver feature
Optics
Electrical
• Electronic, dimmable DALI driver with autonomous dimming: 15-72W. • Constant Light Output (optional)
Available photometric distributions:
Input voltage and frequency: 220-240V, 50-60Hz Class I: standard, Class II: on request Surge protection: 10 kV Rated input power: 14W to 70W
Structures and materials • Housing material: die-cast aluminium body, corrosion resistant screws and brackets • Optic material: coated polycarbonate or aluminium • Colour: RAL7035 • Optical cover: UV stabilized polycarbonate • All materials used in this product are WEEE and ROHS compatible.
Performance • Rated luminous flux range: from 1 200 to 8 20 0 lm at 4000K • Rated luminaire efficacy: up to 122 lm/W at 4000K. • Photometric code: 727/559 , 730/559, 740/559 • Rated median useful life and the associated rated LM factor L80B50: > 218.000 hours • Rated abrupt failure value: 11.5 % • Lumen maintenance code: 9 • Rated ambient temperature (tq) related to Performance for a luminaire: 25°C
• Narrow Asymmetric – medium (B, B2, B5) • Asymmetric – short (C, C5) • Asymmetric forward – very short (D) • Asymmetric – medium (E, E2, E5) • Forward asymmetric – medium (F, F5, G2) • Narrow asymmetric – short (N) • Narrow asymmetric with backlight – short (P, P5) • Narrow asymmetric – medium (R) • Narrow asymmetric – medium (S) • Asymmetric – short (T) • Asymmetric – medium (U) • Pedestrian cross walk (X5, Z5) • Symmetric – medium (Y5)
Rated initial chromaticity co-ordinate values • CIE(x=0.43, y=0.403) 5SDCM • CIE(x= 0.38, y= 0.38) 5SDCM • CIE(x=0.4578, y=0.4101) 5SDCM
Installation and maintenance Mounting options
16 Outdoor range Road & street lighting
347
Rated colour rendering index:>70 Rated correlated colour temperatures*: 2700K, 3000K, 4000K S/P rating for : 2700K: 1.09 , 3000K: 1.33, 4000K: 1.56 ULOR (Upward Light Output Ratio): 0
* Definitions and tolerances according to IEC 62722-2-1. **Rated abrupt failure value depends on the configuration type.
• Side mount bracket ø42mm-60mm • Post top bracket ø48mm-76mm • Universal coupler side ø35mm-76mm • Universal coupler post ø35mm-76mm • Bracket can be adjusted: 0°, +5° (with accessories -5° also available) • Universal Coupler can be adjusted -15°,-10°, -5°, 0°, +5°, +10°, +15° by 5°degree steps • Recommended mounting height: 4-15m • Weight: 5 kg • Only two hand-tools required for installing the fixture • Storage temperature up to 85ºC. • Ambient temperature from -40ºC to 35ºC
Dimensions (mm)
Asymmetric – short
386
72
Road and street lighting
SMBt
Product information Our LED roadway lighting fixture makes all the advantages of LED lighting available for a wide audience. Designed to replace 35-150W HID fixtures, SMBt is a great LED solution for minor roads, residential streets and other public spaces where modest level of illumination is required.
Application areas Residental Road and street Motorways
18 Outdoor range
Car park
20 Outdoor range
Details
SMBt
Driver feature
Optics
Electrical
• Electronic, dimmable (DALI) driver with autonomous dimming: 50W-160W • Minimum dimming level 20W
Available photometric distributions:
Input voltage and frequency: 220-240V, 50-60Hz Class I: standard, Class II: on request Surge protection: 10 kV Rated input power: 52W to 158W
• • Constant Light Output (optional)
Structures and materials • Housing material: die-cast aluminium body, corrosion resistant screws and brackets • Optic material: coated polycarbonate or aluminium • Optical cover: glass • Colour: RAL7035 • All materials used in this product are WEEE and ROHS compatible.
Performance • Rated luminous flux range: from 6 400 to 18 700 lm at 4000K • Rated luminaire efficacy: Up to 146 lm/W at 4000K. • Photometric code: 730/559, 740/559 • Rated median useful life and the associated rated LM factor L80B50: > 102.000 hours • Rated abrupt failure value: 11.5 % • Lumen maintenance code: 9 • Rated ambient temperature (tq) related to performance for a luminaire: 25°C
• Narrow Asymmetric – medium (B, B2, B5) • Asymmetric – short (C, C5) • Asymmetric forward – very short (D) • Asymmetric – medium (E, E2, E5) • Forward asymmetric – medium (F, F5) • Narrow asymmetric – short (N) • Narrow asymmetric with backlight – short (P, P5) • Asymmetric – short (T) • Pedestrian cross walk (X5, Z5) • Symmetric - (Y5) • Asymmetric – medium (U)
Rated initial chromaticity co-ordinate values • CIE(x=0.43, y=0.403) 5SDCM • CIE(x= 0.38, y= 0.38) 5SDCM
103
566
Installation and maintenance Mounting options
20 Outdoor range Road & street lighting
352
Rated colour rendering index:>70 Rated correlated colour temperatures: 3000K, 4000K S/P rating for : 3000K: 1.33, 4000K: 1.56 ULOR (Upward Light Output Ratio): 0
* Definitions and tolerances according to IEC 62722-2-1. **Rated abrupt failure value depends on the configuration type.
• Side mount bracket ø42mm-60mm • Post top bracket ø42mm-76mm • Universal coupler side ø35mm-76mm • Universal coupler post ø35mm-76mm • Bracket can be adjusted: -5°, 0°, +5° • Universal Coupler can be adjusted -15°,-10°, -5°, 0°, +5°, +10°, +15° by 5°degree steps • Weight: 7,5 kg • Storage temperature up to 85ºC. • Ambient temperature from -40ºC to +50ºC up to 140W +40ºC up to 160W
Dimensions (mm)
Narrow Asymmetric – medium
Road and street lighting
SMIx
Product information SMIx offers an optimal solution for street lighting. Modular refractive optic system, a wide range of light distributions can be achieved. The optimized mechanical design provides simple installation, adjustability and reliability.
Application areas Residental Road and street Motorways
22 Outdoor range
24 Outdoor range
Details
SMIx
Driver feature
Optics
Electrical
• Electronic, dimmable (DALI) driver with autonomous dimming: 35-160W
Available photometric distributions:
Input voltage and frequency: 220-240V, 50-60Hz Class I: standard, Class II: on request Surge protection: 10 kV Rated input power: 35W to 160W
Structures and materials • Housing material: die-cast aluminium body and UV stable plastic door with corrosion resistant polyesther powder coat, stainless steel screws and brackets • Optic material: Optical-grade polycarbonate • Optical cover: Tempered glass • Colour: RAL7035 • Impact Strength: IK08 on optical parts, IK09 on housing and coupler • All materials used in this product are WEEE and ROHS compatible.
• C: optimized for high traffic ME class roads • E: optimized for narrow S class roads • F: optimized for wide S class roads
Rated colour rendering index >70 Rated correlated colour temperatures: 3000K, 4000K, 5000K S/P rating for : 3000K: 1.24, 4000K: 1.47, 5000K:1.71 ULOR (Upward Light Output Ratio): 0
Dimensions (mm)
Rated initial chromaticity co-ordinate values
368
• CIE(x=0.43, y=0.403) 5SDCM • CIE(x= 0.38, y= 0.38) 5SDCM • CIE(x= 0.34, y= 0.35) 5SDCM
Performance • Rated luminous flux range: from 5 000 to 22 000 lm • Rated luminaire efficacy: Up to 152 lm/W at 4000K • Rated median useful life and the associated rated LM factor L80B50: > 121.000 hours • Rated abrupt failure value: 3.12 %* • Photometric code: 730/559, 740/559, 750/559 • Lumen maintenance code: 9 • Rated ambient temperature (tq) related to performance for a luminaire: 25°C
154
503
96
* Definitions and tolerances according to IEC 62722-2-1. **Rated abrupt failure value depends on the configuration type.
568
Installation and maintenance Mounting options • Side-mounting coupler for 30-60mm diameters and -15°, -10°, -5°, 0° tilt options • Post top mounting coupler for 30-60mm diameters and 15°, 10°, 5°, 0° tilt options • Weight: 8 kg • Recommended mounting height: 4 - 15m • Only two hand-tools required for installing the fixture • Storage temperature up to 85ºC. • Ambient temperature from -40ºC to 50ºC
24 Outdoor range Road & street lighting
Optimized for high traffic ME class roads
Road and street lighting
Piko
Product information Tungsram’s LED road and street fixture, the PIKO, which makes the advantages of outdoor LED lighting available for everyone, even those on tight budgets. Designed to replace 11-36 W CFL and 35-70 W HID fixtures, the PIKO is a great LED solution for minor roads, residential streets and other public spaces where modest levels of illumination are required.
Application areas Street & residential road lighting Car park
Pedestrian street
Public area 26 Outdoor range
Piko
Optics
Electrical
• Electronic, non-dimmable driver
Available photometric distributions:
Structures and materials
• C: optimized for low traffic M class roads • E: optimized for narrow P type roads • F: optimized for wide P type roads
Input voltage and frequency: 220-240V, 50Hz IEC Safety Classification: Class I Driver surge immunity: 6kV Rated input power: 12W to 28W
• Housing material: die-cast aluminium body, corrosion resistant screws • Color: RAL7035 • Optical cover: tempered glass
Performance • Rated luminous flux range: from 1 500 to 3 600 lm • Rated luminaire efficacy: Up to 140 lm/W • Photometric code: 730/559, 740/559, 750/559 • Rated median useful life and the associated rated LM factor: L80B50 > 110.000 hours • Rated median useful life and the associated rated LM factor: L80B10 > 110.000 hours • Rated median useful life and the associated rated LM factor: L90B50 > 54.000 hours • Rated abrupt failure value: 10% at 50.000 hours • Lumen maintenance code: 9 • Rated ambient temperature (tq) related to performance for a luminaire: 25°C
Rated colour rendering index: >70 Rated correlated colour temperatures: 3000K, 4000K, 5000K S/P rating for: 3000K - 1.33, 4000K - 1.56, 5000K - 1.78 ULOR: 0
Rated initial chromaticity co-ordinate values 3000K - CIE(x=0.43, y=0.403) 5SDCM 4000K - CIE(x= 0.38, y= 0.38) 5SDCM 5000K - CIE(x= 0.34, y= 0.35) 5SDCM
372
140
* Definitions and tolerances according to IEC 62722-2-1. **Rated abrupt failure value depends on the configuration type.
Installation and maintenance Mounting options • Side mount ø35mm-60mm • Recommended mounting height: 4-8m • Weight: 2 kg • Only two hand-tools required for installing the fixture • Storage temperature up to 85ºC. • Ambient temperature from -40ºC to +35ºC
Optimized for residential area
28 Outdoor range Road & street lighting
Dimensions (mm)
61
Details
Driver feature
Road and street lighting
Spinella
Product information Introducing Spinella, single and multiple module roadway fixtures. From residential streets to highways, the Spinella fixture is changing the way you light your roads. Developed and produced in EMEA, balances the technical needs of a sophisticated LED system with the functional demands of a reliable outdoor fixture for all weather conditions, while offering a platform for controls and intelligence.
Application areas
Residential Road and street Motorways
30 Outdoor range
32 Outdoor range
Electrical
Single module
Available photometric distributions:
• Rated luminous flux: from 5 500 lm to 12 720 lm at 5000K
• Narrow Asymmetric – medium (B) • Asymmetric – short (C) • Asymmetric – medium (E) • Forward asymmetric – medium (F) • Narrow asymmetric – short (N) • Narrow asymmetric with backlight – short (P) • Narrow asymmetric – medium (R) • Narrow asymmetric – medium (S) • Asymmetric – short (T) • Asymmetric – medium (U)
Input voltage and frequency: 220-240V, 50-60Hz Class I: standard, Class II: on request Surge protection: 10 kV Rated input power: 52W to 230W Power factor: >0.9
• • •
Photometric code: 730/559, 740/559, 750/559 Lumen maintenance code: 9 Rated ambient temperature (tq) related to performance for a luminaire 25°C*
• Rated median useful life and the associated rated LM factor: L80B50 >128.000 hours (for P≤100W) • Rated abrupt failure value*: 11.14%**
Multiple module • Rated luminous flux: from 7 320 lm to 26 300 lm • Rated luminaire efficacy: up to 121 lm/W • Lumen maintenance code: 9 • Photometric code: 730/559, 740/559, 750/559 • Rated ambient temperature (tq) related to performance for a luminaire 25°C* • Rated median useful life and the associated rated LM factor:L80B50 > 195.000 hours
CIE(x=0.43, y=0.403) 5SDCM CIE(x= 0.38, y= 0.38) 5SDCM CIE(x= 0.34, y= 0.35) 5SDCM
671
Multiple module
977 671
• Side mount ø55mm-60mm • Post top ø55mm-76mm • Coupler can be adjusted to -15°, -10°, -5°, 0°, +5°, +10° and +15° by 5°degree steps. • Weight: 10,5kg (Single), 20,5kg (Multiple) • Recommended mounting height: 6-12m (Single), 6-15m (Multiple)
32 Outdoor range Road & street lighting
420
366
Installation and maintenance
• Ambient temperature from -30ºC to 50ºC. • All materials used in this product are WEEE and ROHS compatible.
366
Rated initial chromaticity co-ordinate values
* Definitions and tolerances according to IEC 62722-2-1. **Rated abrupt failure value depends on the configuration type.
• Only two hand-tools required for installing the fixture. Storage temperature up to 85ºC.
Single module
Rated colour rendering index: >70 at 4000K Rated correlated colour temperatures*: 3000K, 4000K,5000K S/P rating for : 3000K: 1.24, 4000K: 1.47, 5000K:1.71 ULOR (Upward Ligh t Output Ratio): 0
• Rated abrupt failure value*: 5.59 %**
Mounting options
Dimensions (mm)
172
• Rated luminaire efficacy: up to 123 lm/W at 5000K
216
Spinella
Optics
172
Details
Performance
Asymmetric medium
Decorative & Pedestrian lighting
Decorative & Pedestrian lighting
Navona
Product information Navona is a LED solution to replace traditional fixtures in parks, pedestrian areas, city centers. Timeless design incorporates the aesthetic necessities with the optimal optical distribution, providing several lumen packages with symmetrical and asymmetrical distribution and a power range from 16W to 72W to meet a wide range of lighting scenarios. Navona offers a major increase in both vertical and horizontal uniformity. Combined with the high chromatic reproduction contributed by LED technology (white light), this uniform quality facilitates face recognition and visual comfort. Its advanced optical design enables the light to be directed specifically where it is needed.
Application areas Residental City centres (road classifications: from P2 to P6) 36 Outdoor range
Parks
Electrical
• Electronic, programmable & dimmable (DALI and 0-10V**). Controllable driver with astronomical clock availability. Controls system inputs: Analog, DALI, Dynadim ** In case of 0-10V control please do not dimming below 40%.
Available photometric distributions:
Input voltage and frequency: 220-240V, 50-60Hz IEC Protection Class: Class I Surge protection: 10 kV Rated input power: 16W to 72W
Rated colour rendering index >70 Rated correlated colour temperatures: 2700K, 3000K, 4000K ULOR (Upward Light Output Ratio): 0 S/P rating for : 2700K: 1.09, 3000K: 1.24, 4000K: 1.47
Rated initial chromaticity co-ordinate values • CIE(x=0.43, y=0.403) 5SDCM • CIE(x= 0.38, y= 0.38) 5SDCM • CIE(x=0.4578, y=0.4101) 5SDCM 654
• Rated luminous flux range: 1 100 to 7 400 lm • Rated luminaire efficacy: Up to 109 lm/W • Rated median useful life and the associated rated LM factor L80B50: > 200.000 hours • Rated abrupt failure value: 13.2 %* • Photometric code: 727/559 , 730/559, 740/559 • Lumen maintenance code: 9 • Rated ambient temperature (tq) related to performance for a luminaire: 25°C
542
*
Ø76
Ø60
Ø48
500 108
* Definitions and tolerances according to IEC 62722-2-1. ** Rated abrupt failure value depends on the configuration type.
Installation and maintenance Mounting options
38 Outdoor range Decoratove and Pedestrian
**
213
Performance
• 1- and 2-arm through 42-48, 60, 76 mm standard post top mounting. Side mounting through 60 mm diameter pole. • Weight: 11,2 kg • Recommended mounting height: 4-6 m • Ambient operating temperature: -30°C to 50°C • Storage temperature: up to 85°C
*
584*/589**/594***
• Housing material: in three pieces (upper-housing, lowerhousing and arm with coupler), all made from die-cast aluminium with a polyester powder paint finish and oven cured. • Surface finish: polyester powder coat • Colour: RAL9007 • Optical cover:flat tempered glass • All materials used in this product are WEEE and ROHS compatible.
Dimensions (mm)
476*/481**/486***
Structures and materials
• Asymmetric Forward Clear (AFC) • Asymmetric Wide Clear (AWC) • Asymmetric Narrow Clear (ANC) • Asymmetric Wide Diffuser (AWD) • Symmetric Wide Clear (SWC) • Symmetric Wide Diffuser (SWD) • Symmetric Forward Clear (SFC)
584*/589**/594***
Navona
Optics
476*/481**/486***
Details
Driver feature
Symmetric Wide, Forward
Decorative & Pedestrian lighting
Nobila
Product information Introducing Tungsram’s latest LED decorative fixture, the Nobila, which has the advantage of aesthetic outdoor luminaires with great performance. Designed to replace 35-100 W HID and 24-36 W CFL fixtures, the Nobila is a great LED solution for roads, where heritage style is needed.
Application areas Pedestrian street Car park
40 Outdoor range
Street & residential road lighting
Electrical
• Electronic, dimmable driver: Dali, CLO and dynadim from 20-90W • minimum dimming level 5,5 W
Lens layout (4 lenses in every scenario): • A: asymmetric • S: symmetric • C: circular
Input voltage and frequency: 220-240V, 50-60Hz Class I, Class II Surge protection: 10kV Rated input power: 21W to 86W
Structures and materials
Available photometric distributions:
• Rated luminous flux range: from from 2 600 to 9 700lm at 4000K • Rated luminaire efficacy: Up to 135lm/W at 4000K • Photometric code: 730/559, 740/559 • Rated median useful life and the associated rated LM factor L80B50: > 100.000 hours • Rated abrupt failure value: ??? % • Lumen maintenance code: 9 • Rated ambient temperature (tq) related to performance for a luminaire: 25°C
Rated colour rendering index: >70 Rated correlated colour temperatures: 3000K, 4000K S/P rating for: 3000K - 1.33, 4000K - 1.56 ULOR: 0
354
Rated initial chromaticity co-ordinate values
586/591/596
Performance
Dimensions (mm)
362
• Housing material: die-cast aluminium body, corrosion resistant screws • Color: RAL9005 or any RAL color • Optic material: coated polycarbonate • Optical cover: UV stabilized polycarbonate • Gear Tray material: galvanized steel
• C: optimized for high traffic ME class roads • E: optimized for narrow S type roads • F: optimized for wide S class roads • AC - asymetric C • AE - asymetric E • AF - asymetric F • SC - symmetric C • SE - symmetric E • SF - symmetric F • CC - circular C • CE - circular E • CF - circular F
561.5* / 566.5** / 571.5***
Nobila
Optics
362
Details
Driver feature
3000K - CIE(x=0.43, y=0.403) 5SDCM 4000K - CIE(x= 0.38, y= 0.38) 5SDCM
*
P76: Ø60-76mm
* Definitions and tolerances according to IEC 62722-2-1. ** Rated abrupt failure value depends on the configuration type.
**
360
P60: Ø48-60mm ***
Installation and maintenance
P48: Ø45-48mm
Mounting options • Post top coupler ø48mm-76mm • Recommended mounting height: 4-15m • Weight: 6 kg • Only two hand-tools required for installing the fixture • Storage temperature up to 85ºC. • Ambient temperature from -40ºC to +50ºC
Symmetric Wide, Forward
42 Outdoor range Decoratove and Pedestrian
Canopy & Area lighting Canopy & Area lighting
Area lighting
ALIx
Product information ALIx LED outdoor luminaire delivers outstanding features, style and attractive form factor. This latest design offers excellent efficacy even at higher lumen outputs to meet a wide range of area lighting needs. Using reflective optic technology, Tungsram offers superior horizontal and vertical illuminance with high uniformity, while minimizing glare. This system delivers unusually low perceived glare when viewed from beneath. ALIx provides reduced energy consumption, combined with a long rated life that virtually eliminates ongoing maintenance expenses, enabling significant operating cost benefits over the life of the fixture.
Application areas Car park Industrial & logistic Shopping centres Pedestrian crossings 46 Outdoor range
48 Outdoor range
ALIx
Optics
Electrical
• Electronic, dimmable (DALI) driver with autonomous dimming: 32-140W • Minimum dimming level 15W • DynaDimmer • Constant Light Output
Available photometric distributions:
Input voltage and frequency: 220-240V, 50-60Hz Class I, Class II Surge protection: 10 kV Rated input power: 31W to 142W
Structures and materials • Housing material: die-cast aluminium body, corrosion resistant screws and brackets • Optic material: highly reflective aluminium coated plastic • Optical cover: tempered glass • Colour: RAL9007 • All materials used in this product are WEEE and ROHS compatible.
• Asymmetric Forward (AF) • Asymmetric Wide (AW) • Asymmetric Narrow (AN) • Asymmetric Extra Wide Flood (AEF) • Asymmetric Forward Throw Narrow* (AFN) • Symmetrical Wide Flood (SWF) • Symmetrical Narrow Spot (SNS)
Dimensions (mm) 157
*AFN optics only available with Powers 100W &140W
Rated colour rendering index:>70 at 4000K Rated correlated colour temperatures: 3000K, 4000K,5000K S/P rating for : 3000K: 1.24, 4000K: 1.47, 5000K:1.71 ULOR (Upward Light Output Ratio): 0
316
Details
Driver feature
Rated initial chromaticity co-ordinate values
422,2
• CIE(x=0.43, y=0.403) 5SDCM • CIE(x= 0.38, y= 0.38) 5SDCM • CIE(x= 0.34, y= 0.35) 5SDCM 385
Performance • Rated luminous flux range: from 3 600 to 17 600 lm at 5000K • Rated luminaire efficacy: Up to 140lm/W at 5000K. • Photometric code: 730/559, 740/559, 750/559 • Rated median useful life and the associated rated LM factor L80B50 > 131.000 hours • Rated abrupt failure value: 2.5 % • Lumen maintenance code: 9 • Rated ambient temperature (tq) related to performance for a luminaire: 25°C
103,3
114,7
505,9
79,5
* Definitions and tolerances according to IEC 62722-2-1. **Rated abrupt failure value depends on the configuration type.
Installation and maintenance Mounting options
48 Outdoor range Area
• Coupler ø60mm for side-mount or post-top • Adjustable bracket (between -85° and 85° from horizontal) • Recommended mounting height: 8-15m • Tool-less driver maintenance • Storage temperature up to 85ºC. • Operating temperature from -40ºC to 50ºC
Asymmetric Narrow
Canopy lighting
AMIx
Product information AMIx is our latest LED canopy fixture, provides a flexible and rapid installation solution for petrol stations, high bays, parking garages, industrial and other lighting application areas. AMIx is ideally suited both for replacing traditional fixtures such as HID luminaires and for new installations.
Application areas Parking garages Petrol station Industrial High bay Floodlighting
50 Outdoor range
52 Outdoor range
Driver feature
Optics
Electrical
• Electronic, dimmable driver • 150 W with DALI control
Available photometric distributions:
Input voltage and frequency: 220-240V, 50-60Hz IEC Protection Class: Class I Surge protection: 10 kV Rated input power: 39W to 159W
Details
AMIx
Structures and materials • Housing material: die-cast and sheet metal aluminium body,stainless steel screws and brackets • Surface finish: polyester powder coat • Colour: RAL9003 • Optical cover: tempered low-iron glass • All materials used in this product are WEEE and ROHS compatible.
• S25-symmetric 25° • S35- symmetric 35° • S55- symmetric 55° • A25- asymmetric 25° • A35- asymmetric 35° • A55- asymmetric 55°
Dimensions (mm)
Rated colour rendering index >70 Rated correlated colour temperatures: 3000K, 4000K S/P rating for 3000K: 1,33; 4000K: 1,56 ULOR (Upward Light Output Ratio): 0
350
Rated initial chromaticity co-ordinate values
139
• Rated luminous flux range: 4 500 to 18 800 lm • Rated luminaire efficacy: Up to 134lm/W • Rated median useful life and the associated rated LM factor L80B50: > 189.000 hours • Rated abrupt failure value: 12.8 %* • Photometric code: 730/559, 740/559 • Lumen maintenance code: 9 • Rated ambient temperature (tq) related to performance for a luminaire: 25°C * Definitions and tolerances according to IEC 62722-2-1. **Rated abrupt failure value depends on the configuration type.
Installation and maintenance Mounting options • Bezel, surface mount and flood • Weight: 9kg • Recommended mounting height: 4-6 m • Ambient operating temperature: -40°C to 50°C • Storage temperature: up to 85°C
Asymmetric 55°
52 Outdoor range Canopy
350
134.5
Performance
CIE(x= 0.43, y= 0.403) 5SDCM CIE(x= 0.38, y= 0.38) 5SDCM
Area lighting
AHIx
Product information AHIx luminaire offers an optimal LED lighting solution for high lumen package applications. Tried and tested reflective optic technology, combined with the effective thermal management, excellent light efficiency can be maintained throughout the whole lifetime of the luminaire, even under extreme thermal conditions. A wide range of different light distributions makes this luminaire versatile and flexible for numerous application areas. AHIx is a perfect choice for high power LED lighting applications where optical flexibility and reliability are critical.
Application areas Industrial & Maintenance Logistical areas: airports, ports, trains Car park Sport 54 Outdoor range
56 Outdoor range
Driver feature
Optics
Electrical
• Electronic dimmable Dali driver • Minimum dimming level: 30%
Available photometric distributions:
Input voltage and frequency: 220-240V, 50-60Hz IEC Protection Class: Class I Surge protection: 10 kV Rated input power: 200W to 300W
Performance • Rated luminous flux range: 21 000 to 37 600 lm at 5000K • Rated luminaire efficacy: Up to 133lm/W • Rated median useful life and the associated rated LM factor L80B50: > 110.000 hours • Rated abrupt failure value: 3.12 %* • Photometric code: 740/559, 750/559 • Lumen maintenance code: 9 • Rated ambient temperature (tq) related to performance for a luminaire: 25°C
Rated colour rendering index >70 Rated correlated colour temperatures: 4000K, 5000K ULOR (Upward Light Output Ratio): 0
AHIx Remote Driver Luminiare (RST and RSP Accessory Options) 66.5
• Housing material: die-cast and sheet metal aluminium body,stainless steel screws and brackets • Surface finish: polyester powder coat • Colour: RAL9007 • Optical cover: tempered low-iron glass • All materials used in this product are WEEE and ROHS compatible.
Dimensions (mm)
574
Rated initial chromaticity co-ordinate values • CIE(x= 0.38, y= 0.38) 5SDCM • CIE(x= 0.34, y= 0.35) 5SDCM
460
Structures and materials
438 67
AHIx
209
Details
• Asymmetric Forward (AF) • Asymmetric Wide (AW) • Asymmetric Narrow (AN) • Asymmetric Extra Wide Flood (AEF) • Asymmetric Forward Throw Narrow (AFN) • Symmetric Wide Flood (SWF) • Symmetric Narrow Spot (SNS) • Symmetric Forward (SF) • Symmetric Wide (SW)
* Definitions and tolerances according to IEC 62722-2-1. **Rated abrupt failure value depends on the configuration type.
Installation and maintenance
AHIx Integrated Luminiare (ST and SP Accessory Options)
Asymmetric Wide 69
Mounting options
750
56 Outdoor range Area
492
• Adjustable stirrup • Weight: 15kg • Recommended mounting height: 10-40 m • Ambient operating temperature: -40°C to 50°C • Storage temperature: up to 85°C
Asymmetric Forward
Tunnel lighting
Tunnel lighting
TLBt & TMBt
Product information TLBt & TMBt are specially designed for tunnel lighting and available in a wide range for low and high speed tunnels, underpasses and other applications. Maintenance in a tunnel can cause a headache for the operators and for the users as well. The engineers therefore put major focus on developing a highly durable and reliable product with a long lifetime. The products provide easy and fast installation and maintenance to save time and cost. Safety is another important aspect in which lighting plays a key role. Our tunnel lighting solution can improve visibility for drivers with better light quality and as a result they can react faster to emergencies and other situations in tunnels.
Application areas
60 Outdoor range
• Industrial • Floodlight • Underpasses
Driver feature
Optics
Electrical
• Electronic dimmable Dali driver • Minimum dimming level: 30%
Available photometric distributions:
Input voltage and frequency: 220-240V, 50-60Hz Class I: standard, Class II: on request Surge protection: 10 kV • Rated input power: from 32W to 89W(TLBt) • Rated input power: from 130W to 151W (TMBt)
• Housing material: die-cast aluminium • Optical material: aluminised plastic • Optical cover: tempered glass • Colour: RAL9005 • All materials used in this product are WEEE and ROHS compatible.
Performance • Rated luminous flux: from 3 800 to 9 800 lm (TLBt) • Rated luminous flux: from 14 500 to 17 400 lm (TMBt) • Rated luminaire efficacy: up to 120 lm/W • Rated median useful life and the associated rated LM factor L80B50: > 218.000 hours • Rated abrupt failure value: 3.12 %* • Lumen maintenance code: 9 • Rated ambient temperature (tq) related to performance for a luminaire: 25°C
Rated correlated colour temperatures: 4000K S/P rating for 4000K: 1.56 ULOR (Upward Light Output Ratio): 0
Dimensions (mm)
510
Rated initial chromaticity co-ordinate values • CIE(x= 0.38, y= 0.38) 5SDCM
316
Structures and materials
148
TLBt & TMBt
B1:248 B2:297
Details
• Extra narrow Asymmetric – medium (A) • Narrow Asymmetric – medium (B, AQ) • Asymmetric – short (C) • Asymmetric forward – very short (D) • Asymmetric – medium (E) • Extra narrow Symmetric – medium (SA) • Narrow Symmetric – medium (SB) • Symmetric – short (SC) • Symmetric forward – very short (SD) • Symmetric – medium (SE, Y) • Rated colour rendering index:>70
* Definitions and tolerances according to IEC 62722-2-1. **Rated abrupt failure value depends on the configuration type.
150
150
Installation and maintenance 5
. 15
.5
Symmetric Medium
22
62 Outdoor range Tunnel
.5
• Two types of fixing bracket are available: short arm for ceiling mounting, and long arm for wall mounting. Additional mounting solutions are available on request. • Weight: 9 Kg • Recommended mounting height: 4-8 m The LED light engine and driver are replaceable without the need of tools, enabling a quick and easy maintenance solution • Recommended maintenance factor for lighting design: 0.8 • Ambient temperature from -40ºC to 50ºC • Storage temperature up to 85ºC
15
Mounting options
64 Outdoor range
Tunnel lighting overview
What you need to know about tunnel lighting
Tunnel lighting
Interior zone
Good tunnel lighting takes care of good visibility conditions for the road users, this requires lighting levels that are matched with the adaptation level of the users’ eyes. As this adaptation level gradually changes while travelling through the tunnel, for lighting purposes the tunnel can be divided lengthwise into five zones: the access, threshold, transition, interior and exit zone. The decision whether a tunnel or underpass has to be lit during the day depends on • the length of the tunnel • the visibility of the exit • the amount of natural light in the tunnel • the traffic density.
In the interior zone the required lighting levels are related to the structure and size of the tunnel, the speed of the traffic and the traffic density.
The access zone The access zone is not a part of the tunnel itself, but the approach road immediately before the tunnel entrance. The drivers’ vision will have to adapt to the conditions in the tunnel. It is very important that the drivers should be able to see any obstacles or any kind of danger even from this access zone, so that they can react on time.
Lsurrounding
Exit zone
• to make following cars more visible in the rear-view mirror of a car leaving the tunnel • to prepare the driver in case of an emergency when exiting the tunnel.
Emergency lighting Emergency lighting is usually part of the lighting system and guarantees minimal light when the power supply is interrupted.
20º cone
L20
sky
road
surrounding
(See CIE 88)
Recommended threshold/access zone luminance ratios Stopping distance (m)
Symmetrical lighting system Lth/ L20
Counter-beam lighting system Lth/ L20
60 100 160
0.05 0.06 0.10
0.04 0.05 0.07
Recommended interior zone luminances (cd/m2) Stopping distance (m) 60 100 160
The required luminance level in the first section of the threshold zone of the tunnel, which length is equal to the safe stopping distance, will proportionally reduce the amount of light and energy needed. In the second half of the threshold zone the luminance level is decreased rapidly to 40 % of the initial level.
Traffic density <100 veh/h 0.05 0.06 0.10
100<veh/h<1000
>1000 veh/h 0.04 0.05 0.07
Save stopping distance Entrance L20
Transition zone
%L20
Ltrans = Lth (1.9 + t) -1.4
Exit Lth Lexit Ltr
In the transition zone the lighting level is gradually reduced further. The reduction speed is related to the adaptation speed of the eyes but the steps of the reduction should not exceed a ratio of 3:1.
Access zone
Transition zones Time
Lint
Exit zone
Transition zone
treshold zone
threshold zone
64 Tunnel lighting overview
Lroad
In the exit zone the tunnel lighting has to prepare the eye of the drivers for the outside conditions. Even though visual adaptation from low to high level takes place instantaneously, but there are other reasons for installing an increased lighting level in the exit zone:
The threshold zone
Tunnel Lighting should provide the driver with the same safety and comfort as driving on an open road. There should be a smooth lighting transition from approaching, transiting and exiting the tunnel, to help the drivers see all obstacles in the environment and the behaviour of other road users.
Lsky
Interior zone
66 Outdoor range
Reflective
Reflective vs Refractive
Refractive
Great utilisation factor
Primary target Wasted light
Minimized visibility to LED light source, creating non-pixilated appearance to driver’s field of view
Reflective Strengths The perceived direct glare of refractive optics is greater than reflective optics.
Application efficiency Colour dispersion Longevity
APPLICATION EFFICIENCY UNIFORMITY
MANUFACTURING
Refractive Strengths Thermal behavior Luminaire size
COLOR DISPERSION
MAINTENANCE
Like for like Uniformity Maintenance Manufacturing
LONGEVITY
LUMINAIRE SIZE THERMAL BEHAVIOR
66 Great utilisation factor
Visibility to every LED, creating a pixilated appearance and increased glare to driver’s field of view
Reflective Refractive
Name Gen. Optics
SMIx
SLBt
3
Front Glass
Optics
F-Flat Glass
B C D E F N P R S T U B2 B5 C5 E2 E5 F5 G2 P5 X5 Y5 Z5
Power (W)
CCT (K)
Control
Accessories
IEC Protection Classes
Precabling
Control
IEC protection classes
Accessories
Precabling
Mounting
272700
NNo control
M3 Minicell 35lux
D - DALI
SP Extra Surge protection
P76 Post top bracket 48-76mm
303000
NLNo control with CLO
404000
DLDali with CLO YL DynaDim with CLO
F - Fuse LS 7 pin NEMA socket* ** LSP 7 pin NEMA socket + Surge protection* **
2
Mounting
S60 Side mount bracket 42-60mm
Y - DynaDim
CFC CEC CCC FCF FEF EEE ECE EFE FFF
35 50 65 80 100 120 140 160
ST - 6kV Surge immunity (built-in the driver)
D - DALI
PXU48 Pre cabling Universal coupler 30 - 3000K SP - Enhanced surge with X meters C1 - Class I 30-48 mm voltage protection10kV/5kA 40 - 4000K NLxx - No control PCXC2 - Class II U60 + CLO 50 - 5000K LSP - NEMA socket with Pre cabling Universal coupler Shorting Cap + Enhanced with X meters 50-60 mm Surge and connector DLxx - DALI + CLO Voltage Protection 10kV/5kA YLxx - DynaDIM + CLO Yxx - DynaDIM
Example: SMIx/2/FFF/140/40/D/ST/C1/PC3/U60/R7035
ST Standard type
15 20 30 35 40 50 55 70
CCT (K)
N - No control
Order logics Name Gen.
Power (W)
C1 - Class I
NNo precabling
PXXC2 - Class II Precabling with XX meters
U35 Universal coupler 35-42 mm
Name
U50 Universal coupler 42-55 mm U60 Universal coupler 50-60 mm
PIKO
12 18 21 28
C E F
1
U76 Universal coupler 55-76 mm
SR Smart ready connector*
Power (W)
Gen. Optics
CCT (K)
Control
IEC Accessories Protection Classes
3 - 3000K NNo control
4 - 4000K
ST Standard
5 - 5000K
FFuse
C1 Class1
Precabling
Mounting
Px Precabled with x meters
S35 Coupler 3540mm
PCx Precabled with connector with x meters
S60 Coupler 4060mm
Example: : PIKO/1/C/21/4/N/ST/C1/P1/S60
Example: SLBT/3/F/B/20/40/N/ST/C1/N/S60 Name Gen.
Front Glass
Optics
Power (W)
CCT (K)
Control
Accessories
IEC Protection Classes
Precabling
Mounting
Spinella - Single module Front Power Name Gen. Optics Glass (W)
SMBt
3
F-Flat Glass
B C D E F P R S T N U B2 E2 B5 C5 E5 F5 P5 Y5
CCT (K)
Control
N - No control 50 65 80 95 105 120 140 160
D - Dali Yxx - Dynadim 30-3000
Accessories
IEC Protection Classes
Precabling
Mounting
S60 Side mount bracket 42-60mm ST - Standard type M3 - Minicell 35lux
Example: SMBT/3/F/B/75/40/N/ST/C1/N/S60
3
F-Flat Glass
P76 Post top bracket 48-76mm NNo precabling
U35 Universal coupler with insert 35-42 mm
SP - Extra surge C1 - Class I protection PXXC2 - Class II Precabling U50 40-4000 F - Fuse with XX Universal coupler meters with insert 42-55 mm DLxx - Dali with LS - 7 pin NEMA CLO socket U60 Universal coupler YLxx - DynaDim SR - Smart ready with insert 50-60 mm connector with CLO U76 Universal coupler 55-76 mm NLxx - No control with CLO
SP L
B C E F N P R S T U
N - No control 50 65 85 100 110 125
D - DALI external 30-3000 Yxx - Dynadim 40-4000 50-5000 NLxx - Constant Light DLxx - DALI+CLO YLxx - Dynadim+CLO
P76 - Post top, 55-76mm
ST - 6kV surge protection SP - Enhanced surge Nprotection C1 - Class I No precabling LS - 7pin NEMA PXXC2 - Class II Precabling socket with SP * with XX meters M3 - Minicell 35lux F - Fuse with SP
S60 - Side mounted, 55-76mm P50 - Post top, 42-50mm S50 - Side mounted,42-50mm
Spinella - Multiple module N - No control
SP H
3
F-Flat Glass
B C E F N T U
130 150 170 190 210 230
D - DALI 30-3000 40-4000 50-5000
Yxx - DynaDIM
ST - Standard type
NLxx - No control + CLO
LS - 7pin NEMA socket (no SVP)
YLxx - DynaDim + CLO DLxx - DALI + CLO
Example: SP L/3/F/P/100/40/Y/ST/C1/P1/S50
SP H/3/F/B/130/40/N/ST/C1/N/P76
F - Fuse
NC1 - Class I No precabling PX C2 - Class II Precabling with x meters
S60 Side mount 48-60mm P60 Post top 48-60 mm P76 Post top 76 mm
Name Gen.
Optics
Power (W)
CCT (K)
Control
IEC Protection Classes
Accessories
Precabling
Arm Type
Coupler
Name
Gen.
Front Glass
Optics
Navona
NA
3
20 29 30 40 50 60 70
D - Dali 27-2700
40-4000
ST Standard type 10kv Surge immunity (built in driver)
Yxx - Dynadim
30-3000
NLxx - No control + CLO DLxx - Dali + CLO
LS 7 pin NEMA Socket
NC1 - Class I No precabling PXC2 - Class II Precabling with XX meters*
11 arm
48 42- 48 mm
22 arms
60 54-60mm
Sside
7070-76mm
S35Symmetric 35°
AMIx
S55Symmetric 55°
F-Flat Glass
3
A25Asymmetric 25° A35Asymmetric 35°
Example: NA/3/AFC/20/30/D/ST/C1/N/1/60
Optics
Power (W)
CCT (K)
Control
Accessories
IEC Protection Classes
Front Glass
Mounting
Precabling
NOBILA
1
NNo control
730-3000 740-4000
33000 44000
Power (W)
Optics
CCT (K)
Precabling
Mounting
N- No precabling
BBezel
C1 - Class I
PPrecabling
SM Surface Mount
PCPrecabling with quick connector
D - DALI
FL Flood-light
AN - Asymmetric Narrow
Yxx - DynaDIM NLxx - No control + CLO DLxx - DALI + CLO
ST Standard version LS 7-pin NEMA socket
1Class I 2Class II
Px Precabled with x meters
P60 Ø4860mm P76 Ø6076mm
AEF - Asymmetric Extra Wide Flood
AHIx
F-Flat Glass
2
AFN - Asymmetric Forward Throw Narrow SWF - Symmetrical Wide Flood SNS - Symmetrical Narrow Spot
YLxx - DynaDIM + CLO
DDALI
200 250 285 300
44000
IEC Accessories Protection Precabling Classes
Yxx Dynadim
ST Standard Luminaire, Driverbox mounted on luminaire
NLxx RST No control + 5Remote Driver CLO Luminaire, 5000 Driverbox DLxx separated from DALI + luminaire CLO
SW - Symmetrical Wide
Example: NOBILA/1/CC/40/3/N/ST/1/P1/P60
Control
Mounting
NNo control
AW - Asymmetric Wide
D - DALI
20 30 40 50 60 70 80 90
40 55 70 80 100 120 140 160
AF - Asymmetric Forward
N - No control CC CE CF AC AE AF SC SE SF
IEC Protection Classes
Example: AMIx/3/F/S25/100/740/D/C1/N/B Name Gen.
Gen.
Control
A55Asymmetric 55°
YLxx - Dynadim + CLO
Name
CCT (K)
S25Symmetric 25°
N - No control AFC AWC ANC AWD SWC SWD SFC
Power (W)
1Class I 2Class II
NNo precabling
B1 Bracket (Long) B2 Bracket (Short)
PXPrecabling B3 with XX Bracket (Coupler meters Ø60mm)
YLxx Dynadim + CLO
SF - Symmetrial Forward
Example: AHIx/2/F/AF/200/4/D/ST/C1/N/B1
Name Name Gen.
Front Glass
Optics
3
F-Flat Glass
CCT (K)
Control
AF - Asymmetric Forward
NNo control
AW - Asymmetric Wide
DDALI external
AN - Asymmetric Narrow
ALIX
Power (W)
AEF - Asymmetric Extra Wide Flood AFN - Asymmetric Forward Throw Narrow* SWF - Symmetrical Wide Flood SNS - Symmetrical Narrow Spot
32 50 70 100 140
3-3000 4-4000 5-5000
YDynadim NL Constant Light DL DALI +CLO YL Dynadim +CLO
Example: ALIX/3/F/AEF/140/4/D/ST/1/P10/C/R9005/A
Gen.
IEC Accessories Protection Precabling Mounting Special Options Classes
TLBt ST 6kV surge protection Sp Enhanced surge protection LS 7 pin NEMA socket with SP
1 - Class I 2 - Class II
NNo precabling PXXPrecabling with XX meters
C60mm Coupler BBracket
3
Front Optics glass
F
ST - Standard version A2 cable gland cable entries
TMBt
3
F
A B C D E Y AA AB AC AD AE AQ SA SB SC SD SE
Power (W) 32 42 54 65 90
130 150
CCT [K]
Control
Accessories
N -No control D - DALI W - LineSwitch Y - DynaDIM 40-4000 NL - No control + CLO DL - DALI + CLO WL - LineSwitch + CLO YL - DynaDIM +CLO
ST 6kV Surge immunity
N -No control D - DALI W - LineSwitch Y - DynaDIM 40-4000 NL - No control + CLO DL - DALI + CLO WL - LineSwitch + CLO YL - DynaDIM +CLO
ST 6kV Surge immunity
Example: TLBt/3/F/A/32/40/N/ST/C1/N/B1 TMBt/3/F/AB/130/40/N/ST/C1/N/B1
IEC protection class
Precabling
Mounting
C1 Class 1
Nwithout precabling
B1Short bracket for ceiling mounting
C2 Class 2
C1 Class 1 C2 Class 2
PXB2Precabled with Long bracket for wall xm mounting
Nwithout precabling
B1Short bracket for ceiling mounting
PXB2Precabled with Long bracket for wall xm mounting
Outdoor Product Catalogue
May 2019
LED Indoor Product Catalogue
We in Tungsram Operations Kft. are constantly developing and improving our products. For this reason, all product descriptions in this catalogue are intended as a general guide, and we may change specifications from time to time in the interest of product development, without prior notification or public announcement. All descriptions in this publication present only general particulars of the goods to which they refer and shall not form part of any contract. Data in this guide has been obtained in controlled experimental conditions. However, Tungsram cannot accept any liability arising from the reliance on such data to the extent permitted by law.