ZUCCHINI BUSBAR THE BACKBONE OF MODERN BUILDINGS
Zucchini busbar POWERED BY SPECIALISTS
Global strength built on local knowledge Legrand is the global specialist in electrical and digital building infrastructures. Innovation is the driving force behind its development. With an increasing investment in research and development (circa 5% of sales) and more than 4,000 active patents, the Legrand Group is focused on maintaining a high rate of new product launches that present innovative solutions to the market.
CORPORATE SOCIAL RESPONSIBILITY
LEGRAND’S POWER DISTRIBUTION BUSINESS UNIT
Legrand’s CSR roadmap is a natural extension to the governance and sustainable development approach in which the company has been engaged for many years. The CSR roadmap firmly asserts Legrand’s ongoing commitment to sustainable development.
From Legrand transformers, through high power distribution and rising main busbar to Electrak powertrack, desk modules and lighting control, Legrand’s power distribution business unit provides market leading solutions to the increasing demands of today’s buildings.
EMPLOYEES ENVIRONMENT
- Respect human rights - Guarantee health and safety at work - Develop skills and promote diversity
CSR
- Reduce the Group’s environmental footprint - Innovate for a circular economy
SOCIETY - Act ethically - Ensure responsible purchasing - Enable access to electricity for all
USERS - Provide sustainable solutions - Play a driving role in the electrical sector
ZUCCHINI Overview Order
02
LOW POWER Overview Ordering information Technical information
04 06 12
MEDIUM POWER Overview - MS/MR Ordering information - MS/MR Technical information - MS/MR
20/28 21/30 24/43
HIGH POWER Overview Ordering information Technical information
58 62 84
CONTENTS
Electrak, part of the Legrand Group in the UK, is a leading manufacturer of power distribution and lighting control solutions. It's powertrack, floor boxes and grommets, desk modules and lighting control ranges are installed in high specification offices around the world.
1
ZUCCHINI the specialist in busbar systems
Established in 1958 and now part of the Legrand Group, Zucchini has become a leading name in busbar power distribution systems and cast resin transformers. Zucchini busbar is manufactured in state-of-the-art production facilities, including one of the most technically advanced aluminium plating processing units in Europe. These exceptional manufacturing capabilities enable Legrand to offer a fully tested range of products that are superior in terms of quality and design. All Zucchini busbar trunking systems are certified to IEC 61439-6 (BS EN 61439-6) by third party test houses CESI/RINA and are manufactured in accordance with ISO 9001 : 2015 quality standards.
2
An extensive range... The Zucchini range of prefabricated busbars is one of the most comprehensive on the market, ranging from 25 A lighting through to 6300 A high power systems. Zucchini busbar is widely used for power distribution in both industrial and commercial applications. Its modular construction and wide variety of busbar accessories allow an infinite number of trunking combinations, providing a versatile and flexible technical solution to any layout.
LB PLUS - LOW POWER BUSBAR SYSTEM
MEDIUM POWER BUSBAR SYSTEMS
SCP - HIGH POWER BUSBAR SYSTEM
CAST RESIN TRANSFORMERS
LB PLUS is the new range of Zucchini busbars for electrical distribution within low power applications.
Zucchini medium power busbars offer speed, simplicity and flexibility during planning and installation.
SCP is the Zucchini busbar range used for the transport and distribution of high power.
It offers simplicity, high performance and easy installation and can meet all lighting and power demands from 25 A to 63 A.
MS is ideal for commercial and industrial applications from 63 A to 160 A and MR offers the perfect solution for rising mains up to 1000 A.
Legrand also offers a wide range of high quality, environmentally friendly cast resin transformers from 160 kVA up to 17 MVA.
see page 4
see page 20
Ranging from 630 A to 6300 A the dimensions of super compact and its ‘sandwich’ construction enhance resistance to short circuit stresses.
see page 58
This comprehensive range is further enhanced by technical expertise and the ability to create bespoke solutions. visit www.legrand.co.uk
3
ZUCCHINI LB PLUS LIGHTING AND POWER BUSBAR Zucchini LB PLUS is a new range of 25 to 63 A busbars that are ideal for the distribution of power for lighting and low power applications. With a single product, LB PLUS replaces the LB, HL, and SL ranges, offering a busbar that is simpler, better performing, and easier to install.
A winning solution delivering performance and simplicity... with increased functionality, fewer part numbers and common accessories for all versions
SHOPPING CENTRES, STORES, OFFICES
WAREHOUSES, GYMS, UNDERGROUND CAR PARKS
HOSPITALS, LABORATORIES
WORKSHOPS, MAINTENANCE AND REPAIR FACILITIES, PRODUCTION SITES
SIMPLY VERSATILE Ideal for all lighting and power demands up to 63 A Plug outlet covers (hinged and retained), cover tap-off outlets when not in use Feed units and end covers are ordered using one part number 10, 16 and 25 A tap-offs available Tap-off plugs now fitted with spring clamp contacts Tap-offs secure to the bar with twist lock Degree of impact resistance IK 07 Protection index IP 55
NEW TAP-OFF PLUGS Can be moved when the bar is energised With spring clamp contacts Self-extinguishing plastic components IP 55 without using additional accessories Can be fitted with positioning pin to ensure tap-off can only access the correct side of a double-sided bar
Lighting and power distribution in a single product
BRACKETS For ceiling, wall or floor mounting installation Can be positioned anywhere on straight length, even over unused tap-off outlets
5
LB PLUS busbar trunking systems selection chart
25 A 2 conductors
LB PLUS STRAIGHT LENGTHS – TYPE A
40 A
4 conductors
6 conductors
8 conductors
63 A
4 conductors
8 conductors
4 conductors
252
254
256
258
404
408
634
3 m length – 2 outlets
75150101
75160101
–
–
75200101
–
–
3 m length – 4 outlets
–
75160102
–
–
75200102
–
–
3 m length – 2 + 2 outlets
–
–
75170101
75180101
–
75220101
75240101
3 m length – 4 + 4 outlets
–
–
75180102
–
75220102
75240102
–
–
75200111
–
–
–
75220111
75240111
1·5 m length – 2 outlets 1·5 m length – 1 + 1 outlets
LB PLUS STRAIGHT LENGTHS – TYPE B 3 m length – 4 outlets
– 75200111
–
–
252
254
75350102H 75360102H
3 m length – 6 outlets
–
75360103H
3 m length – 4 + 4 outlets
–
–
3 m length – 6 + 6 outlets
–
1·5 m length – 2 outlets 1·5 m length – 1 + 1 outlets
FEED UNITS
75220111
258
404
408
634
–
–
75400102H
–
–
–
–
75400103H
–
–
75370101H 75380101H
– 75400111H
–
256
75420102H 75440102H
–
75380102H
–
–
75400111H
75420111H
75420111H 75440111H
404
408
634
75221003
75201003
75221003
75241003
LH feed unit + end cover (reduced dimensions)
75201004
75221004
75201004
75221004
75241004
Fast it – feed unit RH
75161001
–
–
–
–
Fast it – feed unit LH
75161002
–
–
–
–
Centre feed unit + end covers (reduced dimensions)
75201151
75221151
75201151
75221151
75241151
FLEXIBLE JOINT
75201263
75221263
75201263
75221263
75241263
404
408
634
60 kg suspension bracket
254
258
–
75201003
252
256
–
–
RH feed unit + end cover (reduced dimensions)
BRACKETS AND SUSPENSIONS
254
75420101H 75440101H
– –
252
–
– –
256
75003000 (for TYPE A)
258 and
75003004 for (TYPE B)
Hook for lamp
75003001
Ring
75003002
Pigtail for chain
75003005
5 m steel cable with self locking clamp (TYPE B)
75003008 (TYPE B only)
Bracket with 3 m steel cable (TYPE A)
75003009 (TYPE A only)
CABLE CHANNEL
252
254
256
258
PVC cable channel with cover (3 m)
71000104
Bracket for cable channel
75003006
6
404
408
634
10 A SINGLE PHASE TAP-OFFS
252
254
256
10 A plug with 1 m cable - L1-N
258
404
–
75005012
10 A plug with 1 m cable - L3-N
–
75005013
10 A plug with 1 m cable - L-N2
–
75005014
10 A plug with 3 m cable - L1-N
75005021
10 A plug with 3 m cable - L2-N
–
75005022
10 A plug with 3 m cable - L3-N
–
75005023
10 A plug with 3 m cable - L-N2
–
75005024
252
254
256
258
16 A plug (unfused)
75005000
16 A plug + 1 x (5 x 20)
75005100
16 A plug + 1 x (CH8)
75005200
16 A PRE-WIRED TAP-OFFS
252
254
256
SP & N with 1·5 m cable and 6·3 A fuse - L1-N
258
404
408
634
404
408
634
408
634
408
634
750051001L1
SP & N with 1·5 m cable and 6·3 A fuse - L2-N
–
750051001L2
SP & N with 1·5 m cable and 6·3 A fuse - L3-N
–
750051001L3
SP & N with 1·5 m cable and 6·3 A fuse - L-N2
–
750051001LN2
DP & N with 1·5 m cable and 1 x 6·3 A fuse - L1+L3-N
–
7500510014C
SP & N with 3 m cable and 6·3 A fuse - L1-N
750051003L1
SP & N with 3 m cable and 6·3 A fuse - L2-N
–
750051003L2
SP & N with 3 m cable and 6·3 A fuse - L3-N
–
750051003L3
SP & N with 3 m cable and 6·3 A fuse - L-N2
–
750051003LN2
DP & N with 3 m cable and 1 x 6·3 A fuse - L1+L3-N
–
7500510034C
THREE-PHASE TAP-OFFS – 16 - 25 A
252
254
256
258
404
16 A 3 phase (unfused)
–
75005005
25 A 3 phase (unfused)
–
75007005
25 A 3 phase + 3 x (CH8)
–
75007205
25 A 3 phase + 3 x (CH8) + 4 DIN BOX
–
75007206
25 A 3 phase + (unfused) + 8 DIN BOX
–
75007207
25 A 3 phase + (unfused) + 4 DIN BOX
–
75007006
TAP-OFF ACCESSORIES
634
75005011
10 A plug with 1 m cable - L2-N
16 A PHASE SELECTION TAP-OFFS
408
252
254
256
258
16 A mobile contact
75105000
Window kit code
75105001
404
7
LB PLUS straight lengths – Type B
straight lengths 25-63 A
straight lengths 25-63 A
- - -/- - -
- - -/- - -
LB PLUS straight lengths – Type A
- - -/- - -
- - -/- - -
75360102H
75160102
2 conductors 25 A
4 conductors 25-40 A
6 conductors 25 A
8 conductors 25-40 A
4 conductors 63 A
2 conductors 25 A
Selection chart p. 6-7 Technical data p. 12 Dimensions and technical information p. 14-15 Pack
Cat. Nos.
4 conductors 25-40 A
75150101
Straight lengths – Type A
Pack
Rating (A)
Conductors
Length (m)
Outlet points
Weight (kg)
25
2
3·0
2
3·00
75160101 75160102
Rating (A)
Conductors
Length (m)
Outlet points
Weight (kg)
25 25
4 4
3·0 3·0
2 4
3·10 3·20
256 with 6 x 25 A conductors 1
75170101
Rating (A)
Conductors
25
6
Length (m)
Outlet points
Weight (kg)
3·0
2+2
3·65
Cat. Nos.
75180101 75180102
Rating (A)
Conductors
Length (m)
Outlet points
Weight (kg)
25 25
8 8
3·0 3·0
2+2 4+4
3·75 3·85
404 with 4 x 40 A conductors 1 1 1
75200101 75200102 752001111
Rating (A)
Conductors
40 40 40
4 4 4
Length (m)
Outlet points
Weight (kg)
3·0 3·0 1·5
2 4 2
3·55 3·65 2·00
408 with 8 x 40 A conductors 1 1 1
75220101 75220102 752201112
Rating (A)
Conductors
40 40 40
8 8 8
Length (m)
Outlet points
Weight (kg)
3·0 3·0 1·5
2+2 4+4 1+1
4·70 4·80 2·50
634 with 4 x 63 A conductors 1 1 1
75240101 75240102 75240111
Rating (A)
Conductors
63 63 63
4 4 4
Length (m)
Outlet points
Weight (kg)
3·0 3·0 1·5
2+2 4+4 1+1
4·70 4·80 2·50
1 : For use with both 25 and 40 A systems, and also 2 and 4 conductor versions 2 : For use with both 25 and 40 A systems, and also 6 and 8 conductor versions
8
Straight lengths – Type B
75350102H
Rating (A)
Conductors
Length (m)
Outlet points
Weight (kg)
25
2
3·0
4
5·45
254 with 4 x 25 A conductors 1 1
75360102H 75360103H
Rating (A)
Conductors
Length (m)
Outlet points
Weight (kg)
25 25
4 4
3·0 3·0
4 6
5·55 5·60
256 with 6 x 25 A conductors 1
258 with 8 x 25 A conductors 1 1
4 conductors 63 A
Reinforced highly rigid galvanised steel casing 7 m maximum distance between suspension brackets Conductors insulated with self-extinguishing plastic ZH (zero halogen) Standard tap-off outlets with captive IP 55 plugoutlet covers Mechanical separation of the 2 sides of the bar, (6 and 8 conductor versions) Protection index : IP 55 Impact resistance : IK 07 252 with 2 x 25 A conductors 1
254 with 4 x 25 A conductors 1 1
8 conductors 25-40 A
Selection chart p. 6-7 Technical data p. 13 Dimensions and technical information p. 14-15
Rigid galvanised steel casing 3 m maximum distance between suspension brackets Conductors insulated with self-extinguishing plastic (IEC 60695-2-12 and V0 according to UL94) Standard tap-off outlets with captive IP 55 plugoutlet covers Protection index : IP 55 Impact resistance : IK 07 252 with 2 x 25 A conductors 1
6 conductors 25 A
75370101H
Rating (A)
Conductors
Length (m)
Outlet points
Weight (kg)
25
6
3·0
4+4
6·10
258 with 8 x 25 A conductors 1 1
75380101H 75380102H
Rating (A)
Conductors
Length (m)
Outlet points
Weight (kg)
25 25
8 8
3·0 3·0
4+4 6+6
6·20 6·35
404 with 4 x 40 A conductors 1 1 1
75400102H 75400103H 75400111H1
Rating (A)
Conductors
Length (m)
Outlet points
Weight (kg)
40 40 40
4 4 4
3·0 3·0 1·5
4 6 2
6·00 6·10 3·20
408 with 8 x 40 A conductors 1 1 1
75420101H 75420102H 75420111H2
Rating (A)
Conductors
Length (m)
Outlet points
Weight (kg)
40 40 40
8 8 8
3·0 3·0 1·5
4+4 6+6 1+1
7·10 7·30 3·70
634 with 4 x 63 A conductors 1 1 1
75440101H 75440102H 75440111H
Rating (A)
Conductors
Length (m)
Outlet points
Weight (kg)
63 63 63
4 4 4
3·0 3·0 1·5
4+4 6+6 1+1
7·10 7·30 3·70
1 : For use with both 25 and 40 A systems, and also 2 and 4 conductor versions 2 : For use with both 25 and 40 A systems, and also 6 and 8 conductor versions
LB PLUS trunking components
75161001
75201003
75221263 75201004
Selection chart p. 6-7 Technical data p. 12-13 Dimensions and technical information p. 16-17 Pack
Cat. Nos.
End feed units
Pack
Cat. Nos.
Allow electrical powering of the LB PLUS busbar With terminals for the connection of stranded or solid copper wire cables Delivered with corresponding cable glands Right hand feed units (reduced dimensions) Supplied complete with corresponding end cover Cable terminal capacity 6 mm2 to 25 mm2 Max. cable Ø 32 mm Type
1 1 1
75201003 75221003 75241003
25 / 40 A – 2 / 4 conductor version 25 / 40 A – 6 / 8 conductor version 63 A – 4 conductor version
Weight (kg)
0·80 0·90 0·80
Type
1 1 1
75201151 75221151 75241151
75201004 75221004 75241004
25 / 40 A – 2 / 4 conductor version 25 / 40 A – 6 / 8 conductor version 63 A – 4 conductor version
Weight (kg)
1·00 1·20 1·10
3·70 4·40 2·70
Consists of a right hand and left hand unit Used to change direction, change level or overcome obstructions Flexible cable length : 940 mm
Supplied complete with corresponding end cover Cable terminal capacity 6 mm2 to 25 mm2 Max. cable Ø 32 mm 1 1 1
25 / 40 A – 2 / 4 conductor version 25 / 40 A – 6 / 8 conductor version 63 A – 4 conductor version
Weight (kg)
Flexible joints (reduced dimensions)
Left hand feed units (reduced dimensions)
Type
Centre feed units Centre feed units can be used to power the busbar from an intermediate point of the line, reducing the voltage drop at the end of the line and/or facilitating the installation when the power supply point is near the centre of the line Complete with all internal wiring One set of terminals feeds both left hand and right hand feed sections Supplied with both end caps
Type
1 1 1
75201263 75221263 75241263
25 / 40 A – 2 / 4 conductor version 25 / 40 A – 6 / 8 conductor version 63 A – 4 conductor version
Weight (kg)
2·00 3·10 2·50
Fast fit feed unit Supplied complete with corresponding end cover Cable terminal capacity up to 6 mm2 Cable Ø from 12 mm to 18 mm Type
1 1
75161001 75161002
25 A – 2 / 4 conductor version RH 25 A – 2 / 4 conductor version LH
Weight (kg)
0·45 0·85
9
LB PLUS tap-off plugs
- - -/- - -
- - -/- - 75005013
75005011
75005000
- - -/- - -
- - -/- - -
75007005
75005014
75005012
Selection chart p. 6-7 Technical data p. 12-13 Dimensions and technical information p. 16-17 Pack
Cat. Nos.
10 A single phase tap-offs
75005011 75005021
With 1·5 m cable
n L1-N n L1-N Phase
75005012 75005022
Length (m)
Weight (kg)
Fuseholder
1 3
0·16 0·38
unfused unfused
n L2-N n L2-N
Length (m)
Weight (kg)
Fuseholder
1 3
0·16 0·38
unfused unfused
L3 colour code blue, cable type H05VVF Phase
1 1
75005013 75005023
n L3-N n L3-N
Length (m)
Weight (kg)
Fuseholder
1 3
0·16 0·38
unfused unfused
Phase
1 1 1 1 1
750051001L1 750051001L2 750051001L3 750051001LN2 7500510014C
Phase
75005014 75005024
n L-N2 n L-N2
Length (m)
Weight (kg)
Fuseholder
1 3
0·16 0·38
unfused unfused
16 A phase selection tap-offs For use with Type A and Type B busbar, all ratings Weight (kg)
1 1 1
10
75005000 75005100 75005200
16 A plug (unfused) 16 A plug + 1 x (5x20) 16 A plug + 1 x (CH8)
0·12 0·13 0·13
SP & N with 6·3 A fuse SP & N with 6·3 A fuse SP & N with 6·3 A fuse SP & N with 6·3 A fuse DP & N with 1 x 6·3 A fuse
L1-N L2-N L3-N L-N2 L1+L3-N
With 3 m cable Phase
1 1 1 1 1
750051003L1 750051003L2 750051003L3 750051003LN2 7500510034C
L-N2 colour code magenta, cable type H05VVF 1 1
16 A pre-wired tap-offs
L1 colour code grey, cable type H05VVF
L2 colour code orange, cable type H05VVF 1 1
Cat. Nos.
For use with Type A and Type B busbar, all ratings
Phase
1 1
Pack
For use with Type A and Type B busbar, all ratings
SP & N with 6·3 A fuse SP & N with 6·3 A fuse SP & N with 6·3 A fuse SP & N with 6·3 A fuse DP & N with 1 x 6·3 A fuse
L1-N L2-N L3-N L-N2 L1+L3-N
3 phase tap-offs – 16-25 A For use with Type A and Type B busbar, all ratings
Weight (kg)
1 1 1 1 1 1
75005005 75007005 75007205 75007206 75007207 75007006
16 A 3 phase (unfused) 0·13 25 A 3 phase (unfused) 0·12 25 A 3 phase + 3 x (CH8) 0·12 25 A 3 phase + 3 x (CH8) + 4 DIN box 0·63 25 A 3 phase (unfused) + 8 DIN box 0·80 25 A 3 phase (unfused) + 4 DIN box 0·63
Tap-off accessories
10
75105000
20
75105001
Used with Cat. Nos. 75005000 or 75005100 to make contact with additional conductors on the busbar 16 A mobile contact Enables tap-off to access a single designated side of the busbar Window kit code
LB PLUS busbar trunking system hangers and cable channel
71000104
75003000
75003006
75003004
75003002 75003001
75003005
EEA313
EEC353
Dimensions and technical information p. 18-19 Pack
Cat. Nos.
Hangers
75003000 75003004
60 kg suspension bracket Bracket Cat. No. 75003000 can be used for the suspension of the line and the suspension of light fittings at the same time, while bracket Cat. No. 75003004 may only perform one of the two functions, depending on its rotation For Type A busbar – weight 0·045 kg For Type B busbar – weight 0·045 kg
75003001
Hook for lamp Must always be used with brackets Cat. Nos. 75003000 or 75003004, depending on the type of busbar Weight 0·015 kg
75003002
Ring Must always be used with brackets Cat. Nos. 75003000 or 75003004, depending on the type of busbar Weight 0·015 kg
75003005
Pigtail for chain Must always be used with brackets Cat. Nos. 75003000 or 75003004, depending on the type of busbar Weight 0·015 kg
1
75003007
Spacer on brackets For floor installation Weight 0·040 kg
12
75003008
5 m steel cable with self locking clamp For Type B busbar – weight 0·085 kg
12
75003009
Bracket with 3 m steel cable For Type A busbar – weight 0·05 kg
12 12
10
10
10
PVC cable channel
Pack
Cat. Nos.
1
71000104
PVC cable channel with cover 3 m – weight 0·884 kg
75003006
Bracket for cable channel Must always be used with brackets Cat. Nos. 75003000 or 75003004 depending on the type of busbar and cable channel Cat. No. 71000104 Weight 0·135 kg
6
Steel cable tray Cable tray 1
EEC348
3 m (L) x 50 mm (W) x 13 mm (H)
1
EEA313
Trunking suspended fixing bracket c/w cable tray stirrup. Used when running cable tray on top of busbar trunking
1
EEC353
Cable tray fixing bracket
11
LB PLUS busbar trunking systems technical data n LB PLUS - Type A Type Number of live conductors
252
254
256
258
404
408
634
2
4
6
8
4
8
4 35 x 46
Casing overall dimensions
LxH [mm]
35 x 46
35 x 46
35 x 46
35 x 46
35 x 46
35 x 46
Rated current
In [A]
25
25
25
25
40
40
63
Operating voltage
Ue [V]
400
400
400
400
400
400
400
Insulation voltage
Ui [V]
500
500
500
500
500
500
500
Frequency
f [Hz]
50/60
50/60
50/60
50/60
50/60
50/60
50/60
Rated short-time current (0·1 s)
ICW [kArms]
–
2·2
2·2
2·2
2·7
2·7
2·7
Peak current
Ipk [kA]
–
3·3
3·3
3·3
4·1
4·1
4·1
Single phase rated short-time current (0·1 s)
ICW [kArms]
1·3
1·3
1·3
1·3
1·6
1·6
1·6
Single phase peak current
Ipk [kA]
Thermal limit
I2t [A2s x 106]
2·0
2·0
2·0
2·0
2·4
2·4
2·4
0·174
0·484
0·484
0·484
0·729
0·729
0·729
20° C phase resistance
R20 [mΩ/m]
4·761
4·761
4·761
4·761
3·190
3·190
1·595
Phase resistance at thermal conditions
Rt [mΩ/m]
5·656
5·656
5·656
5·656
3·802
3·802
1·901
Phase reactance (50Hz)
X [mΩ/m]
0·229
0·229
0·229
0·229
0·236
0·236
0·118
Phase impedance
Z [mΩ/m]
4·767
4·767
4·767
4·767
3·199
3·199
1·599
Resistance of the protective conductor1
RPE’ [mΩ/m]
1·695
1·695
1·695
1·695
1·695
1·695
1·695
Reactance of the protective conductor1 (50Hz) XPE [mΩ/m]
0·222
0·222
0·222
0·222
0·222
0·222
0·222
Resistance of the fault loop
Ro [mΩ/m]
6·456
6·456
6·456
6·456
4·885
4·885
3·290
Reactance of the fault loop (50Hz)
Xo [mΩ/m]
0·451
0·451
0·451
0·451
0·458
0·458
0·340
Impedance of the fault loop
Zo [mΩ/m]
6·472
6·472
6·472
6·472
4·906
4·906
3·308
4·123 2
3·570
3·570
3·570
2·830
2·451
1·225
∆V 10-3 cosϕ = 0·70 [V/m/A] ∆V 10
-3
cosϕ = 0·75 [V/m/A]
∆V 10-3 cosϕ = 0·80 [V/m/A] Voltage drop with distributed load referred to V3f 3
2
3·805
3·805
3·805
3·008
2·605
1·302
4·662 2
4·038
4·038
4·038
3·183
2·757
1·378
4·393
∆V 10-3 cosϕ = 0·85 [V/m/A]
4·928 2
4·268
4·268
4·268
3·356
2·906
1·453
∆V 10-3 cosϕ = 0·90 [V/m/A]
5·190 2
4·495
4·495
4·495
3·525
3·052
1·526
∆V 10-3 cosϕ = 0·95 [V/m/A]
5·445 2
4·715
4·715
4·715
3·686
3·192
1·596
∆V 10
5·656 2
4·898
4·898
4·898
3·802
3·293
1·646
-3
cosϕ = 1·00 [V/m/A]
Weight
p [kg/m]
1·00
1·04
1·25
1·28
1·19
1·56
1·56
Fire load
[kWh/m]
1·0
1·0
1·9
1·9
1·0
1·9
1·9
Protection index
IP
55
55
55
55
55
55
55
Degree of impact-resistance
IK
07
07
07
07
07
07
07
Joule effect losses at rated current
P [W/m]
10·6
10·6
10·6
10·6
18·2
18·2
22·6
Ambient temperature min / MAX
t [°C]
-5/+50
-5/+50
-5/+50
-5/+50
-5/+50
-5/+50
-5/+50
1 : Metal casing 2 : Single phase values with distributed load 3 : Three phase ∆V3f = √3/2 x (Rt cosϕ + X sinϕ) ∆V3f(In) = I x L x ∆V3f : (knowing the current and length of the line) ∆V3f(In)% = (∆V3f(In) / Ue) x 100 (%) To calculate the ∆V1f (Single phase) on distributed load: ∆V1f = 1/2 x (2Rt cosϕ + 2X sinϕ) ∆V1f(In) = I x L x ∆V1f : (knowing the current and length of the line) ∆V1f(In)% = (∆V1f(In) / Ue) x 100 (%) I = operating current (A) L = length (m) Short circuit protection for Zucchini’s product ranges (In≤100A) Zucchini busbar trunking systems with a rated current lower than or equal to 100A (LB PLUS-MS 63 and 100) are properly protected through an MCB (Miniature Circuit Breaker) with a rated current lower than or equal to that of the busbar. This protection is guaranteed up to the MCB breaking capacity Product fully in compliance with IEC 61439-6
12
LB PLUS busbar trunking systems technical data n LB PLUS – Type B Type Number of live conductors
252
254
256
258
404
408
634
2
4
6
8
4
8
4 35 x 77
Casing overall dimensions
LxH [mm]
35 x 77
35 x 77
35 x 77
35 x 77
35 x 77
35 x 77
Rated current
In [A]
25
25
25
25
40
40
63
Operating voltage
Ue [V]
400
400
400
400
400
400
400
Insulation voltage
Ui [V]
500
500
500
500
500
500
500
Frequency
f [Hz]
50/60
50/60
50/60
50/60
50/60
50/60
50/60
Rated short-time current (0·1 s)
ICW [kArms]
–
2·2
2·2
2·2
2·7
2·7
2·7
Peak current
Ipk [kA]
–
3·3
3·3
3·3
4·1
4·1
4·1
Single phase rated short-time current (0·1 s)
ICW [kArms]
1·3
1·3
1·3
1·3
1·6
1·6
1·6
Single phase peak current
Ipk [kA]
Thermal limit
I2t [A2s x 106]
2·0
2·0
2·0
2·0
2·4
2·4
2·4
0·174
0·484
0·484
0·484
0·729
0·729
0·729
20 °C phase resistance
R20 [mΩ/m]
4·761
4·761
4·761
4·761
3·190
3·190
1·595
Phase resistance at thermal conditions
Rt [mΩ/m]
5·656
5·656
5·656
5·656
3·802
3·802
1·901
Phase reactance (50Hz)
X [mΩ/m]
0·229
0·229
0·229
0·229
0·236
0·236
0·118
Phase impedance
Z [mΩ/m]
4·767
4·767
4·767
4·767
3·199
3·199
1·599
Resistance of the protective conductor1
RPE’ [mΩ/m]
1·195
1·195
1·195
1·195
1·195
1·195
1·195
Reactance of the protective conductor1 (50Hz) XPE [mΩ/m]
0·274
0·274
0·274
0·274
0·274
0·274
0·274
Resistance of the fault loop
Ro [mΩ/m]
5·956
5·956
5·956
5·956
4·385
4·385
2·790
Reactance of the fault loop (50Hz)
Xo [mΩ/m]
0·503
0·503
0·503
0·503
0·510
0·510
0·392
Impedance of the fault loop
Zo [mΩ/m]
5·977
5·977
5·977
5·977
4·415
4·415
2·817
∆V 10-3 cosϕ = 0·70 [V/m/A]
4·123 2
3·570
3·570
3·570
2·830
2·451
1·225
∆V 10-3 cosϕ = 0·75 [V/m/A]
4·393 2
3·805
3·805
3·805
3·008
2·605
1·302
∆V 10
4·662 2
4·038
4·038
4·038
3·183
2·757
1·378
-3
Voltage drop with distributed load referred to V3f 3
cosϕ = 0·80 [V/m/A]
∆V 10-3 cosϕ = 0·85 [V/m/A]
4·928 2
4·268
4·268
4·268
3·356
2·906
1·453
∆V 10-3 cosϕ = 0·90 [V/m/A]
5·190 2
4·495
4·495
4·495
3·525
3·052
1·526
∆V 10-3 cosϕ = 0·95 [V/m/A]
5·445 2
4·715
4·715
4·715
3·686
3·192
1·596
∆V 10
5·656 2
4·898
4·898
4·898
3·802
3·293
1·646
-3
cosϕ = 1·00 [V/m/A]
Weight
p [kg/m]
1·80
1·83
2·02
2·02
1·98
2·33
2·33
Fire load
[kWh/m]
1·1
1·1
2·1
2·1
1·1
2·1
2·1
Protection index
IP
55
55
55
55
55
55
55
Degree of impact-resistance
IK
07
07
07
07
07
07
07
Joule effect losses at rated current
P [W/m]
10·6
10·6
10·6
10·6
18·2
18·2
22·6
Ambient temperature min·/MAX·
t [°C]
-5/+50
-5/+50
-5/+50
-5/+50
-5/+50
-5/+50
-5/+50
1 : Metal casing 2 : Single phase values with distributed load 3 : Three phase - see pg 12 Temperature rating schedule according to the room temperature Room temperature [°C] 15 20 25 30 35 40 45 50 55 60 K1 Factor 1·15 1·12 1·08 1·05 1·025 1 0·975 0·95 0·93 0·89 Multiplier coeficient of rated current for room temperature values different from 40° C Mechanical loads permitted table The table shows the maximum weights (kg) that can be supported, both for concentrated, and distributed loads
LB PLUS – TYPE A LB PLUS – TYPE B
Distance between suspension brackets
Concentrated load
1·5 2·0 3·0 5·0 7·0
40 30 20 13 7
Distributed Distributed load
50 kg/m 30 kg/m 13 kg/m 5 kg/m 2 kg/m
(75 kg)4 (60 kg)4 (39 kg)4 (25 kg)4 (14 kg)4
4 : Distributed load total weight
13
LB PLUS busbar trunking systems technical information n LB PLUS – Type A – 252/254/404
1·5 sided only) 1.5 m - 2 outlets outlets (single (one side only)
3 m - 2 outlets (single sided only) (one side only)
3 m - 4 outlets (single sided only) (one side only)
n LB PLUS – Type B – 252/254/404 1·5 sided only) 1.5 m - 2 outlets outlets (single (one side only)
3 m - 4 outlets (single sided only) (one side only)
3 m - 6 outlets (single sided only) (one side only)
All dimensions (mm) are nominal
14
LB PLUS busbar trunking systems technical information n LB PLUS – Type A – 256/258/408/634
1·5 1+1outlets outlets (double sided) 1.5 m - 1+1
3 m -- 2+2 2+2 outlets (double sided)
3 m - 4+4 4+4outlets outlets (double sided)
n LB PLUS– Type B – 256/258/408/634 1·5 1+1outlets outlets (double sided) 1.5 m - 1+1
3 m - 4+4 4+4outlets outlets (double sided)
3 m -- 6+6 6+6outlets outlets (double sided)
All dimensions (mm) are nominal
15
LB PLUS busbar trunking systems technical information n Trunking components
n Tap-offs
Feed unit 254
Plug 10 A PLUG 10 A
27
62
173
CH32 Cable section: Cable diameter:
Plug 10 A
max 6 mm2 min 12 mm max 18 mm
L1-N GREY L2-N ORANGE L3-N BLUE L-N2 MAGENTA
Cable 33x1.5 x 1.5mm mm2 CABLE
PLUG 10A
Feed unit (reduced dimensions) 40 / 63 A 408
115
60 62
115
85
115
85
85
Plug 16 A
47
283
52
PG21
32
Ø 80
104
227
366
min 1,5 mm2 max 2,5 mm2 Cable diameter : min 8 mm max 13 mm
Cable section :
82
82
82
85
404 / 634
366
227 Cable section: Cable diameter:
Plug 25 A
min 6 mm2 max 25 mm2 max 32 mm
Cat. Nos. 75007005 / 75007205 160
58
44
58
32
40 40
126
2 max
Right
50
End cover
71
Left 220
2 max
Cable section: max 6 mm2 Cable diameter: min 8 mm max 16 mm
58
40
50
116 162
160
Flexible joint (reduced dimensions) 404 / 408 / 634 408
115
85
940
366
227
940
366
200
227
71
950
404 / 603
82
85
A A = 128 mm (4 DIN) 200 mm (8 DIN)
Cable diameter: min 13 mm max 17 mm All dimensions (mm) are nominal
16
LB PLUS busbar trunking systems technical information n Colour coding for 10 A single phase tap-offs
2 CONDUCTORS
4 CONDUCTORS three-phase
4 CONDUCTORS dual single phase
L1 N2 L N
6 CONDUCTORS
8 CONDUCTORS L1 L2 L3 N
L3-N 75005013 / 75005023
L2-N 75005012 / 75005022
L1 L2 L3 N
L1-N 75005011 / 75005021
L1-N 75005011 / 75005021
L2-N 75005012 / 75005022
L3-N 75005013 / 75005023
48 xCONDUCTORS SINGLE PHASE
All dimensions (mm) are nominal
17
LB PLUS busbar trunking systems technical information n Hangers and cable channel 60 kg suspension bracket for Type B busbar Cat. No. 75003004
60 kg suspension bracket for Type A busbar Cat. No. 75003000
Ø
Ring Cat. No. 75003002
13
Ø
Ø1
2
7
40
40
.5
Pig tail for chain Cat. No. 75003005
5 m steel cable with self-locking clamp for Type B busbar Cat. No. 75003008 5 metres
50
Hook for lamp Cat. No. 75003001
Bracket with 3 m steel cable for Type A busbar Cat. No. 75003009 3 metres
Bracket for cable channel PVC cable channel with cover Cat. No. 71000104
31
Cat. No. 75003006 45
Cat. No. 71000104 SLOT 7x11
Ø7
SLOT 7x11
Cat. Nos. 75003000 75003004
All dimensions (mm) are nominal
18
Spacer on brackets for loor installation Cat. No. 75003007 15 mm
145
Ø7
LB PLUS busbar trunking systems installation methods
LB PLUS requires a fixing bracket Cat. No. 75003000 for Type A and a fixing bracket Cat. No. 75003004 for Type B Both brackets come with a 6¡5 mm Ă˜ hole and can be fixed to 6 mm2 threaded rod
n Suspension For suspension, the bracket must be fitted with a range of appropriate accessories, which must be added according to the installation requirements Ceiling suspension of LB PLUS Type A
n Suspension of light fittings LB PLUS - single and double sided For the suspension of light fittings, use hook Cat. No. 75003001 or ring Cat. No. 75003002 These accessories can be installed on the brackets used for the suspension of the busbar (Cat. Nos. 75003000 and 75003004).
Pigtail for chain This solution is possible by ordering suspension bracket item Cat. No. 75003000 and accessory Cat. No. 75003005, preset for the connection of a chain 75003005
75003000 Bracket with steel cable This solution is already supplied as a kit Cat. No. 75003009, consisting of a suspension bracket and a 3 m steel cable
75003009 Ceiling suspension of LB PLUS Type B 5 m cable with self locking clamp This accessory Cat. No. 75003008 allows the suspension of the reinforced (Type B) straight lengths using the slots along the reinforcement plate at the top of the bar
75003008
All dimensions (mm) are nominal
19
ZUCCHINI MS LOW TO MEDIUM POWER BUSBAR The flexibility of the Zucchini MS range during planning and installation makes it ideal for frequently changing requirements in small to medium sized commercial and industrial premises. With versions ranging from 63 A to 160 A, the vast selection of elbows, tees and other accessories make any configuration possible, with bespoke solutions also available on request. In addition to the wide range of accessories, a choice of tap-off boxes from 16 to 63 A accommodate protection devices up to 16 DIN modules.
To find out more call our technical support team on +44 (0) 370 608 9020
20
MS double sided busbar low and medium power 63/100/160 A
End cover (see p. 23)
Tap-off box for 4 modules (see p. 23)
51501351
51515074
Trunking length
Tap-off box for 8 modules (see p. 23)
51510101
51515075
Suspension bracket (see p. 23)
Right end feed unit (see p. 22)
51002002
51511051
Joint cover (see p. 23) 51500161
Dimensions and technical information p. 24 Technical data p. 27 Conforms to BS EN 61439-6. Casing manufactured from Senzimir quality galvanised steel suitable for use as a protective earth IP 40 as standard, increasing to IP 55 with use of appropriate accessories Pack
Cat. Nos.
63 A trunking lengths
Pack
Tap-off outlets are spaced every 1·0 m on both sides and are fitted with shutters to prevent accidental contact with live parts Expansion joints are not required
Standard lengths Length (m)
1 1 1 1 1 1
51530101 51530116 51530115 51530114 51530112 51530113
3 2 1·5 1 < 1·5 > 1·5
Outlet points
Weight (kg)
3+3 2+2 1+1 1+1 – –
7·890 5·260 3·945 2·630 – –
Cat. Nos.
160 A trunking lengths Standard lengths Length (m)
1 1 1 1 1 1
51520101 51520116 51520115 51520114 51520112 51520113
1
515EFB01
1
515IFB01
3 2 1·5 1 < 1·5 > 1·5
Outlet points
Weight (kg)
3+3 2+2 1+1 1+1 – –
9·290 6·190 4·645 3·100 – –
Fire barrier kit E120 L1 N L2 L3
External fire barrier kit for use with 63 A, 100 A and 160 A trunking lengths Internal fire barrier kit for use with 63 A, 100 A and 160 A trunking lengths
100 A trunking lengths Standard lengths Length (m)
1 1 1 1 1 1
51510101 51510116 51510115 51510114 51510112 51510113
3 2 1·5 1 < 1·5 > 1·5
Outlet points
Weight (kg)
3+3 2+2 1+1 1+1 – –
7·890 5·260 3·945 2·630 – –
21
MS double sided busbar trunking components
51511151
51500361 51500461
Dimensions and technical information p. 24-25 Conforms to BS EN 61439-6. Casing manufactured from Senzimir quality galvanised steel suitable for use as a protective earth IP 40 as standard, increasing to IP 55 with use of appropriate accessories Pack
Cat. Nos.
Trunking components
Pack
Cat. Nos.
Horizontal elbows – right hand Right and left elbows differ because of the position of junction blocks 1 1 1
51530351 51500361 51520351
Rating (A)
Weight (kg)
63 100 160
1·6 1·6 2·6
Horizontal elbows – left hand
1 1 1
51530361 51500362 51520361
Rating (A)
Weight (kg)
63 100 160
1·6 1·6 2·6
Vertical elbows – right hand
1 1 1
51530451 51500461 51520451
Rating (A)
Weight (kg)
63 100 160
1·6 1·7 2·7
1 1 1
51530561 51500562 51520561
1 1 1
51530461 51500462 51520461
Weight (kg)
63 100 160
1·6 1·6 2·6
Rating (A)
Weight (kg)
63 100 160
2·29 2·29 3·79
Left hand tee – male
1 1 1
51530581 51500564 51520581
Rating (A)
Weight (kg)
63 100 160
2·29 2·29 3·79
Crossovers
1 1 1
51530651 51500661 51520651
Rating (A)
Weight (kg)
63 100 160
2·29 2·29 3·79
Flexible elbow For horizontal and vertical changes of direction up to 90° Not available for 160 A rating
Vertical elbows – left hand Rating (A)
Trunking components (continued) Left hand tee – female
For changing the route of trunking, either horizontally or vertically
1 1
51511261 51521261
Rating (A)
Weight (kg)
63-100 160
2·29 3·79
Feed units End feed units IP 55
Right hand tees – male
1 1 1
51530551 51500561 51520551
Rating (A)
Weight (kg)
63 100 160
2·29 2·29 3·79
Right hand tees – female
1 1 1
51530571 51500563 51520571
Rating (A)
Weight (kg)
63 100 160
2·29 2·29 3·79
IP 55 protection as standard. Supplied with cable clamp and terminals for 35 mm (MS 63/100) and 70 mm (MS 160) cables Switched-end feed units are also available with in-line bus switches on request Rating (A)
1
51511051
1
51511052
1
51521051
1
51521052
Right 63-100 Left 63-100 Right 160 Left 160
Weight (kg)
1·874 2·218 2·360
Centre feed units IP 55
1 1
22
51511151 51521151
Right
1·732
Rating (A)
Weight (kg)
63-100 160
3·5 5·0
Left
MS double sided busbar tap-offs and accessories
Tap-offs can be supplied pre-wired and itted with protective devices Contact us on +44 (0) 345 600 6266
51515058 51500161
51515056
51515052
51515051
51500160
Dimensions and technical information p. 25-26 Tap-off boxes can be used to connect and energise one and three phase loads up to 63 A. Tap-offs can be inserted and removed when the busbar is energised and when the fixture is under load, up to a capacity 32 A. Compliant with IEC 60695-2-10 with V1 self-extinguishing degree (UL 94) Standard IP 55 degree of protection Pack
Cat. Nos.
Tap-off boxes IP 55
Pack
Cat. Nos.
Energy withstand 400·10 A S Totally insulated tap-off box Max. cable size 25 mm2 3
2
Tap-off box with CH10 fuseholder (10·3 x 38) 10·3 x 38 fuses not included
Max. power losses 10 W Empty tap-off box with DIN (4 mod.) Rating (A)
1
1
51515071
51515072
Rating (A)
1
51515051
1
51515052
1
51515057
1
51515056
1
51515067
1
51515058
Weight (kg)
32 0·68 Tap-off box for (4 mod.) DIN Rating (A)
Weight (kg)
32
0·73
Empty tap-off box (8 mod) 1
51515073
32 0·93 Tap-off box (4 mod) DIN (long version) Rating (A)
1
51515074
1
51515075
Weight (kg)
Weight (kg)
32 0·96 Tap-off box (8 mod) DIN (long version) Rating (A)
Weight (kg)
32
0·99
Weight (kg)
16 0·908 Tap-off box with CH14 fuseholder (14 x 51) 14 x 51 fuses not included Rating (A)
Max. power losses 16 W Rating (A)
Tap-off boxes with isolating device on the cover
Weight (kg)
50 0·908 63 A tap-off boxes Energy withstand 400·103 A2S Max power losses 20W Tap-off box with transparent cover Weight 1·1 kg Tap-off box with transparent cover and hinged door (up to 4 mod.) Weight 1·2 kg Tap-off box with hinged door (up to 7 mod.) Weight 1·1 kg Tap-off box with hinged door (up to 16 mod.) Energy withstand 400·103 A2S Max power losses 20W Weight 2·5 kg
Accessories
1
1
1
1
51501351
End cover IP 55 End covers are fitted to the last length in each run to maintain IP 55 protection Weight 0·57 kg
51500161
Joint cover IP 55 One for each joint Weight 0·788 kg
51500160
Tap-off outlet cover IP 55 6 per 3 m straight length Weight 0·061 kg
51002002
Suspension bracket Universal fixing brackets enable trunking to be either suspended or wall mounted 1 per 2 m Weight 0·1 kg
23
MS double sided busbar technical information n General features
n Trunking components
MS is fully compliant with IEC 61439-6 (BS EN 61439-6) Specifically, the rated current of the Zucchini busbar trunking system is always referred to the average ambient temperature of 40°C (NB : the standard requires 35°C), thus offering the market suitably oversized products
IP 55 (according to BS EN 60529)
n Trunking lengths
Horizontal elbow - right hand
Horizontal elbow - left hand
135
365
365
8
Vertical elbow - right hand
Vertical elbow - left hand 8
135
365
365
135
135
8
The components and the features of the MS trunking lengths are : • a casing made of Senzimir quality galvanised steel, with a sheetmetal thickness that allows its use as the protective earth (PE) and ensures the electrical continuity during mounting with no added accessories • section bar dimensions : 39 x 97 mm • number of conductors : 4 with the same section 3P + N available for capacities 63 A, 100 A and 160 A • separation between the conductors using plastic insulating devices, reinforced with 20% of glass fibres, which ensure a V1 selfextinguishing degree (according to UL94) and are in compliance with the glow-wire test according to IEC 60695-2-10 • tap-off outlets with a constant centre distance of 1 m on both sides of the busbar (3 + 3 outlets every 3 m), set up for connection to tap-off boxes • an electric joint block, with silver-plated copper contacts for automatically connecting live parts and the PE (protective earth) Quick connection between straight lengths. One operation provides an electrical and mechanical connection, whilst at the same time, IP 40 protection is guaranteed. The upgrade to IP 55 is easily achieved by adding joint covers and outlet covers. Flame retardant in compliance with the IEC 60332-3 standard • trunking lengths with fire barrier (internal + external) are used when fire-resistant walls need to be passed through. The lengths fitted with a fire barrier have been lab-tested (in accordance with DIN 4102-9 and EN 1366-3) in order to confirm that, if correctly installed, they will maintain the essential fire-resistant features of the wall • trunking lengths with thrust unit are provided with a device which blocks the conductors from slipping when supporting the weight of the riser (when installed vertically). This type of length is required for 10 m riser intervals
135
8
Right hand tees - male
Right hand tees - female 135
135 365
365 8
8
365
365
8
8
18
97
70
25
L1 N L2 L3
39
Left hand tees - female
Left hand tees - male
135
135
365
365
8
8
3 000 865
1 000
1 000
365
135 230
365 8
230 135
1 000
1 000
8
865
Flexible elbow
Crossovers 8
615 8
365
135
216
365 8
All dimensions (mm) are nominal
24
n End feed units
Tap-off boxes
Installation is carried out with a quick junction connection The feed units have terminals for the connection of copper cables for sections of up to 35 mm2 for the 63/100 A feed unit and 70 mm2 for the 160 A feed unit The entrance point of the cables is positioned at the end of the feed unit 63 – 100 A 273 10
125
right
10
Max. cable size 35 mm2
10
Max. cable size 70 mm2
85
left
160 A 200
273
211
10
No. 2 d 1 = max. Ø 63
Standard version
right 10
left
These boxes are available in a wide range of versions : • 63 A empty boxes (only with a terminal board for connecting cables), with an internal DIN rail and transparent door • 16 A - available with a set of three cylindrical fuse carriers (10·3 x 38 mm) • 16/32 A - available with a set of three cylindrical fuse carriers DIAZED (D01 : 16 A; D02 : 32 A); • 50 A – available with cylindrical fuse carriers (14 x 51 mm) • 63 A – available with 4-7-16 DIN mod. • 16 to 63 A – available with a disconnection device integral with the cover
10
Max. cable size 35 mm2 160
n Centre feed units 63 – 100 A 8
273
270
273
d 1 max. = 38
118
150
6·5
165 d 1 = max. Ø 55
Used to connect and energise single phase and three phase loads up to 63 A. Features include : • the PE contact (protective earth) is the first to make an electrical connection when inserting the box into the outlet and it is the last to disconnect when removing • compliance with all insulating plastic components according to the glow-wire test (IEC 60695-2-10) with V1 self-extinguishing degree (UL94) • standard IP 55 degree of protection without using additional accessories • can be inserted and removed when the busbar is energised and when the fixture is under load, up to a capacity of 32 A
6·5
Max. cable size 25 mm2
8
180
10
No. 2 d 1 = max. Ø 55
Max. cable size 35 mm2 97
10
100
No. 2 d 1 = max. Ø 55
Long version
400
273
8
200
No. 2 d 1 = max. Ø 63
160
273
13
8
16
Max. cable size 70 mm2
10
Max. cable size 35 mm2
d 1 max. = 38
160 A
6·5
250
6·5
Max. cable size 25 mm2
97
10
120
No. 2 d 1 = max. Ø 63
All dimensions (mm) are nominal
25
MS double sided busbar technical information n Tap-off box with CH10 fuseholder (10·3 x 38)
n End stop 310
5·5
55
IP 55
160 d 1 = max. Ø 29
Max. cable size 10 mm2
42
145
5·5
n Joint cover
d 1 = max. Ø 29
IP 55
310
10
77
n Tap-off box with CH14 fuseholder (14 x 51)
Max. cable size 35 mm2 10
117
42
221·5
n Tap-off outlet cover IP 55
82
d 1 = max. Ø 38
10
109
n 63 A tap-off boxes
Max. cable size 35 mm2 10
n Suspension bracket
283 d 1 = max. Ø 55
80
Hole 7 x 11
132
Hole 7 x 11
Hole 7 x 11 64
131
d 1 = max. Ø 55
Tap-off box with hinged door (up to 16 modules DIN) Hole 7 x 11 10
20
d 1 = max. Ø 55
Max. cable size 35 mm2
78
10
155
285
487 511
All dimensions (mm) are nominal
26
Ø7
MS double sided busbar technical data
Complies to : IEC 61439-6 (BS EN 61439-6) Suitable for the following climates : Constant humid climate (IEC 60068 2 – 11) Cyclical humid climate (IEC 60068 2 – 30) Short circuit protection for Zucchini product ranges (In≤100 A) Zucchini busbar systems with a nominal current less or equal to 100 A (LB PLUS / MS 63 and 100 A) are correctly protected against short circuit effects through an MCB (Miniature Circuit Breaker) with a nominal current less or equal to the one of the busbar This protection is assured up to MCB short circuit withstand The busbar trunking systems LB PLUS / MS 63 and 100 A are flame retardant in compliance with IEC 60332-3 Rating (A) Live conductors No. Casing overal dimension A x B (mm) Rated current In (A) Cross-section of conductors (3P + N) S (mm2) Cross-section of protective conductor eq. Cu SPE (mm2) Operational voltage Ue (V) Insulation voltage Ui (V) Rated frequency f (Hz) Rated short-time current (0·1 s) Icw (kA)rms Peak current Ipk (kA) Maximum thermal limit I2† (A2s x 106) Phase resistance R20 (mΩ/m) Phase reactance (50Hz) X (mΩ/m) Phase impedance Z (mΩ/m) Resistance of the protective bar RPE (mΩ/m) Reactance of the protective bar (50Hz) XPE (mΩ/m) Resistance of the fault loop Ro (mΩ/m) Reactance of the fault loop (50Hz) Xo (mΩ/m) Impedance of the fault loop Zo (mΩ/m) ∆V (V/m/A)10-3 cosϕ = 0·70 ∆∆V (V/m/A)10-3 cosϕ = 0·75 ∆V1F = 1 (2 R20 cosϕ +2 X senϕ) 2 ∆∆V (V/m/A)10-3 cosϕ = 0·80 Voltage drop with distributed load (k) ∆∆V (V/m/A)10-3 cosϕ = 0·85 ∆∆V (V/m/A)10-3 cosϕ = 0·90 ∆V3F = √ 3 (R20 cosϕ + X senϕ) ∆∆V (V/m/A)10-3 cosϕ = 0·95 2 ∆∆V (V/m/A)10-3 cosϕ = 1·00 Straight length weight p (kg/m) Fire load (kWh/m) Protection degree IP Losses for the Joule effect at full load P (W/m) Min./max. ambient temperature † (°C)
63
100
160
4 39 x 97 63 26 21 400 750 50/60 3·5 5·25 1·225 1·250 0·366 1·302 0·857 0·102 2·11 0·468 2·16 1·102 1·148 1·191 1·231 1·264 1·288 1·251 2·0 1·64 40/55 17·21 -5/+50
4 39 x 97 100 26 21 400 750 50/60 5 10 2·500 0·837 0·247 0·873 0·857 0·102 1·69 0·349 1·73 0·806 0·842 0·875 0·906 0·933 0·954 0·934 2·5 1·64 40/55 32·34 -5/+50
4 39 x 97 160 39 21 400 750 50/60 5·5 10 3·025 0·478 0·247 0·538 0·857 0·102 1·34 0·349 1·38 0·547 0·546 0·579 0·591 0·600 0·602 0·563 2·8 1·64 40/55 49·93 -5/+50
Temperature rating schedule Mean room temperature (°C) K1 factor
15
20
25
30
35
40
45
50
55
60
1·15
1·12
1·08
1·05
1·025
1
0·975
0·95
0·93
0·89
Multiplier coefficient of nominal rating for room temperature values different from 40°C
27
ZUCCHINI MR MEDIUM RATING BUSBAR Available in sizes from 160 to 1000 A, MR (medium rating) busbar is ideal for power distribution in medium to large installations and rising mains in commercial buildings. MR is available with aluminium or copper conductors and has a large range of tap-off boxes from 16 to 1000 A, allowing the supply and protection of a wide range of loads using devices such as fuses, MCBs and MCCBs.
Trunking lengths are available in single and double sided versions with aluminium or copper conductors
Tap-off boxes are available pre-wired or empty with plugin or bolt-on options
SWITCHBOARD TRANSFORMER FEED UNIT
Metal end feed unit (centre feed and switched end feed units are also available)
Joint covers guarantee mechanical rigidity and maintain IP 55 protection
HORIZONTAL ELBOW
VERTICAL ELBOW
TAP-OFF BOXES
Lowering lifetime installation costs MR features a monobloc electrical jointing system. The shearhead bolt on the monobloc allows for fast assembly of the run and guarantees long-term reliability and safety. As well as being quick to install, Zucchini MR busbar is easy to upgrade if existing installations need to be modified. The vast choice of elbows, tees and other accessories make any configuration possible, with bespoke solutions also available on request.
For information on data centre busbar
Contact us on +44 (0) 370 608 9020 29
MR medium rating busbar medium power 160 - 1 000 A
Tap-off box (see p. 39)
Suspension bracket (see p. 42)
Tap-off box (see p. 39)
50414064
50632001
50414063
End feed unit (see p. 37) 50401102
Tap-off box (see p. 39) 50414075
Trunking length 50400102
Dimensions and technical information p. 43 Measuring bespoke dimensions p. 49 Technical data p. 52-56 IP 55 (according to BS EN 60529) Flame retardant in compliance with IEC 60332-3. Fully compliant with IEC 61439-6 (BS EN 61439-6) Rated currents are at an average ambient temperature of 40° C (over and above the required standard of 35° C) Pack
Trunking lengths – 3 m
Cat. Nos.
Pack
Trunking lengths – bespoke dimensions
Cat. Nos.
For vertical runs or riser applications. Special lengths between 400 mm and 3 m are available upon request
Please specify required length when ordering (see p. 49 – how to measure bespoke dimensions)
With 3 + 3 outlets Tap-off outlets are spaced every 1·0 m on both sides (6 positions per 3 m length) Aluminium
1 1 1 1 1 1 1 1
50400101 50400102 50400103 50400104 50400108 50400105 50400106 504001071
Copper
55400102 55400103 55400104 55400105 55400106 55400107
Rating (A)
160 250 315 400 500 630 800 1 000
1 501 to 2 999 mm lengths with 2 + 2 outlets Tap-off outlets in fixed position on both sides
Weight (kg) Aluminium Copper
19·9 20·9 22·8 33·8 37·5 41·7 44·3 46·8
– 25·7 28·1 36·9 – 56·0 72·1 83·7
With 5 outlets on one side
Aluminium
1 1 1 1 1 1 1 1
50400151 50400152 50400153 50400154 50400158 50400155 50400156 504001571
Copper
55400152 55400153 55400154 55400155 55400156 55400157
Rating (A)
50400251 50400252 50400253 50400254 50400258 50400255 50400256 504002571
55400252 55400253 55400254 55400255 55400256 55400257
160 250 315 400 500 630 800 1 000
– 25·7 28·1 36·9 – 56·0 72·1 83·7
Without outlets Feeder lengths. A tap-off point is only possible on the junction between two lengths (see bolt-on tap-off boxes p. 41) Rating (A)
1 1 1 1 1 1 1 1
50400241 50400242 50400243 50400244 50400248 50400245 50400246 504002471
55400242 55400243 55400244 55400245 55400246 55400247
160 250 315 400 500 630 800 1 000
Rating (A)
1 1 1 1 1 1 1 1
50400121 50400122 50400123 50400124 50400128 50400125 50400126 504001271
55400122 55400123 55400124 55400125 55400126 55400127
160 250 315 400 500 630 800 1 000
Weight (kg) Aluminium Copper
19·9 20·9 22·8 33·8 37·5 41·7 44·3 46·8
– 25·7 28·1 36·9 – 56·1 72·1 83·7
1 : The 1 000 A aluminium is supplied painted RAL 7035 as standard
30
Feeder lengths. A tap-off point is only possible on the junction between two lengths (see bolt-on tap-off boxes p. 41)
Weight (kg) Aluminium Copper
19·9 20·9 22·8 33·8 37·5 41·7 44·3 46·8
160 250 315 400 500 630 800 1 000 1 501 to 2 999 mm lengths without outlets
Suitable for rising mains (see p. 50) 1 1 1 1 1 1 1 1
Rating (A)
Key : How to select the correct configuration and finish All examples on this page show 4 conductor galvanised lengths No. of conductors and finish is dictated by the red number 0= 4 conductors. Galvanised 2 = 4 conductors. Painted 1= 5 conductors. Galvanised MRF-P 3= 5 conductors. Painted Replace 0 with 1, 2, or 3 if required
MR medium rating busbar medium power 160 - 1 000 A
Tap-off box (see p. 39)
Suspension bracket (see p. 42)
Tap-off box (see p. 39)
50414064
50632001
50414063
End feed unit (see p. 37) 50401102
Tap-off box (see p. 39) 50414075
Trunking length 50400102
Dimensions and technical information p. 43-44 Measuring bespoke dimensions p. 49 Technical data p. 52-56 IP 55 (according to BS EN 60529) Flame retardant in compliance with IEC 60332-3. Fully compliant with IEC 61439-6 (BS EN 61439-6) Rated currents are at an average ambient temperature of 40° C (over and above the required standard of 35° C) Pack
Trunking lengths – bespoke dimensions
Cat. Nos.
Pack
Accessories for trunking lengths
Cat. Nos.
(continued)
External fire barriers
Please specify required length when ordering (see p. 49 – how to measure bespoke dimensions) 1 000 to 1 500 mm lengths with 1 + 1 outlets Tap-off outlets in fixed position on both sides Aluminium
1 1 1 1 1 1 1 1
50400141 50400142 50400143 50400144 50400148 50400145 50400146 504001471
Copper
55400142 55400143 55400144 55400145 55400146 55400147
Rating (A)
160 250 315 400 500 630 800 1 000 600 to 1 500 mm lengths without outlets Feeder length. A tap-off point is only possible on the junction between two lengths (see bolt-on tap-off boxes p. 41) Rating (A)
1 1 1 1 1 1 1 1
50400111 50400112 50400113 50400114 50400118 50400115 50400116 504001171
55400112 55400113 55400114 55400115 55400116 55400117
160 250 315 400 500 630 800 1 000
1 : The 1 000 A aluminium is supplied painted RAL 7035 as standard
Please specify the required position of the external fire barrier when ordering (see p. 44) Aluminium
1 1 1 1 1 1 1 1
554EFB01 554EFB01 554EFB01 554EFB02 554EFB02 554EFB02 554EFB02 554EFB02
Copper
554EFB01 554EFB01 554EFB01 554EFB02 554EFB02 554EFB02
Rating (A)
160 250 315 400 500 630 800 1 000 Internal fire barriers Please specify the required position of the internal fire barrier when ordering (see p. 44) Rating (A)
1 1 1 1 1 1 1 1
554IFB01 554IFB02 554IFB03 554IFB04 554IFB06 554IFB07 554IFB08 554IFB09
554IFB01 554IFB02 554IFB05 554IFB04 554IFB06 554IFB07
160 250 315 400 500 630 800 1 000
Tap-off outlet cover IP 55
1
50403601
Suitable for all MR versions 6 for each length Weight : 0·10 kg
Key : How to select the correct configuration and finish All examples on this page show 4 conductor galvanised lengths No. of conductors and finish is dictated by the red number 0= 4 conductors. Galvanised 2 = 4 conductors. Painted 1= 5 conductors. Galvanised MRF-P 3= 5 conductors. Painted Replace 0 with 1, 2, or 3 if required
31
MR medium rating busbar single elbows
Vertical elbow – left hand
Horizontal elbow – right hand Horizontal elbow – left hand
Vertical elbow – right hand
Dimensions and technical information p. 44 Measuring bespoke dimensions p. 49 MR is fully compliant with IEC 61439-6 (BS EN 61439-6) Rated currents are at an average ambient temperature of 40° C (over and above the required standard of 35° C) Angles are 90° as standard. Other angles available on request. IP 55 (according to BS EN 60529) Pack
Single elbows – standard dimensions (300 + 300 mm)
Cat. Nos.
Pack
Single elbows – bespoke dimensions
Cat. Nos.
Please specify required length when ordering
Horizontal elbow – right hand Aluminium
1 1 1 1 1 1 1 1
50400301 50400302 50400303 50400304 50400308 50400305 50400306 504003071
Copper
55400302 55400303 55400304 55400305 55400306 55400307
Rating (A)
160 250 315 400 500 630 800 1 000
Weight (kg) Aluminium Copper
8·1 8·2 8·4 14·5 14·9 15·4 15·7 16·0
– 9·2 9·6 11·0 – 18·7 21·4 23·3
Horizontal elbow – left hand Rating (A)
1 1 1 1 1 1 1 1
50400311 50400312 50400313 50400314 50400318 50400315 50400316 504003171
55400312 55400313 55400314 55400315 55400316 55400317
160 250 315 400 500 630 800 1 000
Weight (kg) Aluminium Copper
8·1 8·2 8·4 14·5 14·9 15·4 15·7 16·0
– 9·2 9·6 11·0 – 18·7 21·4 23·3
Vertical elbow – right hand Rating (A)
1 1 1 1 1 1 1 1
50400401 50400402 50400403 50400404 50400408 50400405 50400406 504004071
55400402 55400403 55400404 55400405 55400406 55400407
160 250 315 400 500 630 800 1 000
Weight (kg) Aluminium Copper
8·1 8·2 8·4 14·5 14·9 15·4 15·7 16·0
– 9·2 9·6 11·0 – 18·7 21·4 23·3
Vertical elbow – left hand Rating (A)
1 1 1 1 1 1 1 1
50400411 50400412 50400413 50400414 50400418 50400415 50400416 504004171
55400412 55400413 55400414 55400415 55400416 55400417
160 250 315 400 500 630 800 1 000
50400321 50400322 50400323 50400324 50400328 50400325 50400326 504003271
Copper
55400322 55400323 55400324 55400325 55400326 55400327
8·1 8·2 8·4 14·5 14·9 15·4 15·7 16·0
– 9·2 9·6 11·0 – 18·7 21·4 23·3
Rating (A)
160 250 315 400 500 630 800 1 000 Horizontal elbow – left hand 250 to 900 mm per arm Rating (A)
1 1 1 1 1 1 1 1
50400331 50400332 50400333 50400334 50400338 50400335 50400336 504003371
55400332 55400333 55400334 55400335 55400336 55400337
160 250 315 400 500 630 800 1 000 Vertical elbow – right hand 300 to 900 mm per arm Rating (A)
1 1 1 1 1 1 1 1
50400421 50400422 50400423 50400424 50400428 50400425 50400426 504004271
55400422 55400423 55400424 55400425 55400426 55400427
Weight (kg) Aluminium Copper
1 : The 1 000 A aluminium is supplied painted RAL 7035 as standard
32
Aluminium
1 1 1 1 1 1 1 1
Horizontal elbow – right hand 250 to 900 mm per arm
160 250 315 400 500 630 800 1 000 Vertical elbow – left hand 300 to 900 mm per arm Rating (A)
1 1 1 1 1 1 1 1
50400431 50400432 50400433 50400434 50400438 50400435 50400436 504004371
55400432 55400433 55400434 55400435 55400436 55400437
160 250 315 400 500 630 800 1 000
Key : How to select the correct configuration and finish All examples on this page show 4 conductor galvanised lengths No. of conductors and finish is dictated by the red number 0= 4 conductors. Galvanised 2 = 4 conductors. Painted 1= 5 conductors. Galvanised MRF-P 3= 5 conductors. Painted Replace 0 with 1, 2, or 3 if required
MR medium rating busbar double elbows
Vertical elbow – left + right hand Horizontal elbow – right + left hand
Horizontal elbow – left + right hand
Vertical elbow – right + left hand
Dimensions and technical information p. 44 Measuring bespoke dimensions p. 49 MR is fully compliant with IEC 61439-6 (BS EN 61439-6) Rated currents are at an average ambient temperature of 40° C (over and above the required standard of 35° C) Angles are 90° as standard. Other angles available on request. IP 55 (according to BS EN 60529) Pack
Double elbows – standard dimensions (300 + 300 + 300 mm)
Cat. Nos.
Pack
Double elbows – bespoke dimensions
Cat. Nos.
Please specify required length when ordering
Horizontal elbow – right + left hand Aluminium
1 1 1 1 1 1 1 1
50400341 50400342 50400343 50400344 50400348 50400345 50400346 504003471
Copper
55400342 55400343 55400344 55400345 55400346 55400347
Rating (A)
160 250 315 400 500 630 800 1 000
Weight (kg) Aluminium Copper
10·29 10·55 11·06 18·37 19·50 20·55 21·20 21·80
– 12·23 12·97 15·72 – 25·77 30·88 34·55
Horizontal elbow – left + right hand Rating (A)
1 1 1 1 1 1 1 1
50400351 50400352 50400353 50400354 50400358 50400355 50400356 504003571
55400352 55400353 55400354 55400355 55400356 55400357
160 250 315 400 500 630 800 1 000
1 1 1 1 1 1 1 1
50400441 50400442 50400443 50400444 50400448 50400445 50400446 504004471
55400442 55400443 55400444 55400445 55400446 55400447
160 250 315 400 500 630 800 1 000
10·29 10·55 11·06 18·37 19·50 20·55 21·20 21·80
– 12·23 12·97 15·72 – 25·77 30·88 34·55
1 1 1 1 1 1 1 1
50400451 50400452 50400453 50400454 50400458 50400455 50400456 504004571
55400452 55400453 55400454 55400455 55400456 55400457
160 250 315 400 500 630 800 1 000
Copper
55400362 55400363 55400364 55400365 55400366 55400367
10·29 10·55 11·06 18·37 19·50 20·55 21·20 21·80
– 12·23 12·97 15·72 – 25·77 30·88 34·55
– 12·23 12·97 15·72 – 25·77 30·88 34·55
1 : The 1 000 A aluminium is supplied painted RAL 7035 as standard
160 250 315 400 500 630 800 1 000
Rating (A)
1 1 1 1 1 1 1 1
50400371 50400372 50400373 50400374 50400378 50400375 50400376 504003771
55400372 55400373 55400374 55400375 55400376 55400377
160 250 315 400 500 630 800 1 000 Vertical elbow – right + left hand 300 to 900 mm per arm Rating (A)
1 1 1 1 1 1 1 1
50400461 50400462 50400463 50400464 50400468 50400465 50400466 504004671
55400462 55400463 55400464 55400465 55400466 55400467
160 250 315 400 500 630 800 1 000 Vertical elbow – left + right hand 300 to 900 mm per arm
Weight (kg) Aluminium Copper
10·29 10·55 11·06 18·37 19·50 20·55 21·20 21·80
Rating (A)
Horizontal elbow – left + right hand 250 to 900 mm per arm
Weight (kg) Aluminium Copper
Vertical elbow – left + right hand Rating (A)
50400361 50400362 50400363 50400364 50400368 50400365 50400366 504003671
Weight (kg) Aluminium Copper
Vertical elbow – right + left hand Rating (A)
Aluminium
1 1 1 1 1 1 1 1
Horizontal elbow – right + left hand 250 to 900 mm per arm
Rating (A)
1 1 1 1 1 1 1 1
50400471 50400472 50400473 50400474 50400478 50400475 50400476 504004771
55400472 55400473 55400474 55400475 55400476 55400477
160 250 315 400 500 630 800 1 000
Key : How to select the correct configuration and finish All examples on this page show 4 conductor galvanised lengths No. of conductors and finish is dictated by the red number 0= 4 conductors. Galvanised 2 = 4 conductors. Painted 1= 5 conductors. Galvanised MRF-P 3= 5 conductors. Painted Replace 0 with 1, 2, or 3 if required
33
MR medium rating busbar combination vertical + horizontal elbows
Combination vertical + horizontal elbow right + left hand
Combination vertical + horizontal elbow right + right hand
Combination vertical + horizontal elbow left + left hand
Combination vertical + horizontal elbow left + right hand
Dimensions and technical information p. 44 Measuring bespoke dimensions p. 49 MR is fully compliant with IEC 61439-6 (BS EN 61439-6) Rated currents are at an average ambient temperature of 40° C (over and above the required standard of 35° C) Angles are 90° as standard. Other angles available on request. IP 55 (according to BS EN 60529) Pack
Combination vertical + horizontal elbows – standard dimensions (300 + 300 + 300 mm)
Cat. Nos.
Pack
Combination vertical + horizontal elbows – bespoke dimensions
Cat. Nos.
Please specify required length when ordering
Right hand + right hand Aluminium
1 1 1 1 1 1 1 1
50400501 50400502 50400503 50400504 50400508 50400505 50400506 504005071
Copper
55400502 55400503 55400504 55400505 55400506 55400507
Rating (A)
160 250 315 400 500 630 800 1 000
Weight (kg) Aluminium Copper
10·29 10·55 11·06 18·37 19·50 20·55 21·20 21·80
– 12·23 12·97 15·72 – 25·77 30·88 34·55
Right hand + left hand Aluminium
1 1 1 1 1 1 1 1
50400511 50400512 50400513 50400514 50400518 50400515 50400516 504005171
Copper
55400512 55400513 55400514 55400515 55400516 55400517
Rating (A)
160 250 315 400 500 630 800 1 000
Aluminium
50400521 50400522 50400523 50400524 50400528 50400525 50400526 504005271
Copper
55400522 55400523 55400524 55400525 55400526 55400527
Rating (A)
160 250 315 400 500 630 800 1 000
10·29 10·55 11·06 18·37 19·50 20·55 21·20 21·80
– 12·23 12·97 15·72 – 25·77 30·88 34·55
1 1 1 1 1 1 1 1
50400531 50400532 50400533 50400534 50400538 50400535 50400536 504005371
Copper
55400532 55400533 55400534 55400535 55400536 55400537
Rating (A)
160 250 315 400 500 630 800 1 000
10·29 10·55 11·06 18·37 19·50 20·55 21·20 21·80
– 12·23 12·97 15·72 – 25·77 30·88 34·55
55400542 55400543 55400544 55400545 55400546 55400547
10·29 10·55 11·06 18·37 19·50 20·55 21·20 21·80
– 12·23 12·97 15·72 – 25·77 30·88 34·55
Rating (A)
160 250 315 400 500 630 800 1 000 Right hand + left hand 300 to 900 mm per arm Rating (A)
1 1 1 1 1 1 1 1
50400551 50400552 50400553 50400554 50400558 50400555 50400556 504005571
55400552 55400553 55400554 55400555 55400556 55400557
160 250 315 400 500 630 800 1 000 Left hand + right hand 300 to 900 mm per arm Rating (A)
1 1 1 1 1 1 1 1
50400561 50400562 50400563 50400564 50400568 50400565 50400566 504005671
55400562 55400563 55400564 55400565 55400566 55400567
160 250 315 400 500 630 800 1 000 Left hand + left hand 300 to 900 mm per arm
Weight (kg) Aluminium Copper
1 : The 1 000 A aluminium is supplied painted RAL 7035 as standard
34
Copper
Weight (kg) Aluminium Copper
Left hand + left hand Aluminium
50400541 50400542 50400543 50400544 50400548 50400545 50400546 504005471
Weight (kg) Aluminium Copper
Left hand + right hand 1 1 1 1 1 1 1 1
Aluminium
1 1 1 1 1 1 1 1
Right hand + right hand 300 to 900 mm per arm
Rating (A)
1 1 1 1 1 1 1 1
50400571 50400572 50400573 50400574 50400578 50400575 50400576 504005771
55400572 55400573 55400574 55400575 55400576 55400577
160 250 315 400 500 630 800 1 000
Key : How to select the correct configuration and finish All examples on this page show 4 conductor galvanised lengths No. of conductors and finish is dictated by the red number 0= 4 conductors. Galvanised 2 = 4 conductors. Painted 1= 5 conductors. Galvanised MRF-P 3= 5 conductors. Painted Replace 0 with 1, 2, or 3 if required
MR medium rating busbar combination horizontal + vertical elbows
Combination horizontal + vertical elbows right + left hand
Combination horizontal + vertical elbows right + right hand
Combination horizontal + vertical elbows left + left hand
Combination horizontal + vertical elbows left + right hand
Dimensions and technical information p. 44 Measuring bespoke dimensions p. 49 MR is fully compliant with IEC 61439-6 (BS EN 61439-6) Rated currents are at an average ambient temperature of 40° C (over and above the required standard of 35° C) Angles are 90° as standard. Other angles available on request. IP 55 (according to BS EN 60529) Pack
Cat. Nos
.
Combination horizontal + vertical elbows – standard dimensions (300 + 300 + 300 mm)
Pack
Cat. Nos
.
Please specify required length when ordering
Right hand + right hand Aluminium
1 1 1 1 1 1 1 1
50400601 50400602 50400603 50400604 50400608 50400605 50400606 504006071
Copper
55400602 55400603 55400604 55400605 55400606 55400607
Rating (A)
160 250 315 400 500 630 800 1 000
Weight (kg) Aluminium Copper
10·29 10·55 11·06 18·37 19·50 20·55 21·20 21·80
– 12·23 12·97 15·72 – 25·77 30·88 34·55
Right hand + left hand Aluminium
1 1 1 1 1 1 1 1
50400611 50400612 50400613 50400614 50400618 50400615 50400616 504006171
Copper
55400612 55400613 55400614 55400615 55400616 55400617
Rating (A)
160 250 315 400 500 630 800 1 000
– 12·23 12·97 15·72 – 25·77 30·88 34·55
Left hand + right hand Aluminium
1 1 1 1 1 1 1 1
50400621 50400622 50400623 50400624 50400628 50400625 50400626 504006271
Copper
55400622 55400623 55400624 55400625 55400626 55400627
Rating (A)
160 250 315 400 500 630 800 1 000
Aluminium
1 1 1 1 1 1 1 1
50400641 50400642 50400643 50400644 50400648 50400645 50400646 504006471
Copper
55400642 55400643 55400644 55400645 55400646 55400647
– 12·23 12·97 15·72 – 25·77 30·88 34·55
50400651 50400652 50400653 50400654 50400658 50400655 50400656 504006571
55400652 55400653 55400654 55400655 55400656 55400657
1 1 1 1 1 1 1 1
50400631 50400632 50400633 50400634 50400638 50400635 50400636 504006371
Copper
55400632 55400633 55400634 55400635 55400636 55400637
Rating (A)
160 250 315 400 500 630 800 1 000
– 12·23 12·97 15·72 – 25·77 30·88 34·55
1 : The 1 000 A aluminium is supplied painted RAL 7035 as standard
160 250 315 400 500 630 800 1 000
Rating (A)
1 1 1 1 1 1 1 1
50400661 50400662 50400663 50400664 50400668 50400665 50400666 504006671
55400662 55400663 55400664 55400665 55400666 55400667
160 250 315 400 500 630 800 1 000 Left hand + left hand 300 to 900 mm per arm
Weight (kg) Aluminium Copper
10·29 10·55 11·06 18·37 19·50 20·55 21·20 21·80
160 250 315 400 500 630 800 1 000
Left hand + right hand 300 to 900 mm per arm
Left hand + left hand Aluminium
Rating (A)
Rating (A)
1 1 1 1 1 1 1 1
Weight (kg) Aluminium Copper
10·29 10·55 11·06 18·37 19·50 20·55 21·20 21·80
Right hand + right hand 300 to 900 mm per arm
Right hand + left hand 300 to 900 mm per arm
Weight (kg) Aluminium Copper
10·29 10·55 11·06 18·37 19·50 20·55 21·20 21·80
Combination horizontal + vertical elbows – bespoke dimensions
Rating (A)
1 1 1 1 1 1 1 1
50400671 50400672 50400673 50400674 50400678 50400675 50400676 504006771
55400672 55400673 55400674 55400675 55400676 55400677
160 250 315 400 500 630 800 1 000
Key : How to select the correct configuration and finish All examples on this page show 4 conductor galvanised lengths No. of conductors and finish is dictated by the red number 0= 4 conductors. Galvanised 2 = 4 conductors. Painted 1= 5 conductors. Galvanised MRF-P 3= 5 conductors. Painted Replace 0 with 1, 2, or 3 if required
35
MR medium rating busbar horizontal tees and crossovers
Horizontal tee left hand – male
Horizontal tee right hand – female Horizontal tee left hand – female
Horizontal tee right hand – male
Dimensions and technical information p. 45 Measuring bespoke dimensions p. 49
Crossover
MR is fully compliant with IEC 61439-6 (BS EN 61439-6) Rated currents are at an average ambient temperature of 40° C (over and above the required standard of 35° C) Angles are 90° as standard. Other angles available on request IP 55 (according to BS EN 60529) Pack
Pack
Please specify required length when ordering Arms can be 250 to 900 mm
Horizontal tees – standard dimension (300 + 300 + 300 mm)
Cat. Nos.
Right hand – female Aluminium
Right hand – female Aluminium
1 1 1 1 1 1 1 1
50400701 50400702 50400703 50400704 50400708 50400705 50400706 504007071
1 1 1 1 1 1 1 1
50400711 50400712 50400713 50400714 50400718 50400715 50400716 504007171
Aluminium
Aluminium
1 1 1 1 1 1 1 1
50400721 50400722 50400723 50400724 50400728 50400725 50400726 504007271
1 1 1 1 1 1 1 1
50400731 50400732 50400733 50400734 50400738 50400735 50400736 504007371
Aluminium
Copper
55400702 55400703 55400704 55400705 55400706 55400707
Copper
55400712 55400713 55400714 55400715 55400716 55400717
Copper
55400722 55400723 55400724 55400725 55400726 55400727
Copper
55400732 55400733 55400734 55400735 55400736 55400737
Rating (A)
Weight (kg) Aluminium Copper
160 11·2 250 11·4 315 11·8 400 18·4 500 19·5 630 20·0 800 20·5 1 000 21·0 Right hand – male Rating (A)
Rating (A)
160 250 315 400 500 630 800 1 000
– 12·8 13·4 15·7 – 24·4 28·5 31·3
Weight (kg) Aluminium Copper
160 11·2 250 11·4 315 11·8 400 18·4 500 19·5 630 20·0 800 20·5 1 000 21·0 Left hand – male Rating (A)
– 12·8 13·4 15·7 – 24·4 28·5 31·3
Weight (kg) Aluminium Copper
160 11·2 250 11·4 315 11·8 400 18·4 500 19·5 630 20·0 800 20·5 1 000 21·0 Left hand – female
– 12·8 13·4 15·7 – 24·4 28·5 31·3
Weight (kg) Aluminium Copper
11·2 11·4 11·8 18·4 19·5 20·0 20·5 21·0
– 12·8 13·4 15·7 – 24·4 28·5 31·3
Key : How to select the correct configuration and finish All examples on this page show 4 conductor galvanised lengths No. of conductors and finish is dictated by the red number 0= 4 conductors. Galvanised 2 = 4 conductors. Painted 1= 5 conductors. Galvanised MRF-P 3= 5 conductors. Painted Replace 0 with 1, 2, or 3 if required
36
Horizontal tees – bespoke dimensions
Cat. Nos.
1 1 1 1 1 1 1 1
50400741 50400742 50400743 50400744 50400748 50400745 50400746 504007471
Copper
55400742 55400743 55400744 55400745 55400746 55400747
Rating (A)
160 250 315 400 500 630 800 1 000 Right hand – male Rating (A)
1 1 1 1 1 1 1 1
50400751 50400752 50400753 50400754 50400758 50400755 50400756 504007571
55400752 55400753 55400754 55400755 55400756 55400757
160 250 315 400 500 630 800 1 000 Left hand – female Rating (A)
1 1 1 1 1 1 1 1
50400761 50400762 50400763 50400764 50400768 50400765 50400766 504007671
55400762 55400763 55400764 55400765 55400766 55400767
160 250 315 400 500 630 800 1 000 Left hand – male Rating (A)
1 1 1 1 1 1 1 1
50400771 50400772 50400773 50400774 50400778 50400775 50400776 504007771
55400772 55400773 55400774 55400775 55400776 55400777
160 250 315 400 500 630 800 1 000
Crossovers – standard dimension (300 + 300 + 300 + 300 mm) Aluminium
1 1 1 1 1 1 1 1
50403001 50403002 50403003 50403004 50403008 50403005 50403006 504030071
Copper
55403002 55403003 55403004 55403005 55403006 55403007
Rating (A)
160 250 315 400 500 630 800 1 000
Weight (kg) Aluminium Copper
15·5 15·7 16·1 27·5 29·3 29·1 29·5 29·9
– 17·6 18·4 21·1 – 35·2 40·2 43·7
1 : The 1 000 A aluminium is supplied painted RAL 7035 as standard
MR medium rating busbar feed units
Feed unit left end Right end up feed unit with AC23 switch disconnector
Feed unit right end
End stop
Dimensions and technical information p. 45 Measuring bespoke dimensions p. 49 MR is fully compliant with IEC 61439-6 (BS EN 61439-6) Rated currents are at an average ambient temperature of 40° C (over and above the required standard of 35° C) IP 55 (according to BS EN 60529) Pack
Feed units
Cat. Nos.
Pack
Feed units (continued)
Cat. Nos.
End feed unit with AC23 switch disconnector This feed unit allows isolation of the line for maintenance Right end up
Metal end feed units For plates and hole dimensions refer to switchboard-transformer feed units with same rating (p. 38) Left end Aluminium
1 1 1 1 1 1 1 1
50401131 50401132 50401133 50401134 50401138 50401135 50401136 50401137
Copper
55401132 55401133 55401134 55401135 55401136 55401137
Rating (A)
160 250 315 400 500 630 800 1 000 Right end Rating (A)
1 1 1 1 1 1 1 1
50401121 50401122 50401123 50401124 50401128 50401125 50401126 50401127
55401122 55401123 55401124 55401125 55401126 55401127
160 250 315 400 500 630 800 1 000
Weight (kg) Aluminium Copper
17·74 17·76 17·83 23·22 23·20 23·63 23·70 24·00
– 18·47 18·70 19·58 – 26·07 27·80 29·03
Weight (kg) Aluminium Copper
16·64 16·76 17·03 18·32 20·00 19·43 19·80 20·20
– 17·37 17·70 18·88 – 21·17 23·30 24·83
Aluminium
1 1 1 1 1 1 1 1
Aluminium
Copper
55401112
Rating (A)
160 250 Right end Rating (A)
1 1
50401101 50401102
55401102
160 250
Weight (kg) Aluminium Copper
6·80 6·85
– 7·20
Weight (kg) Aluminium Copper
5·70 5·85
55403405 55403406 55403407
1 1 1 1 1 1 1 1
50403411 50403412 50403413 50403414 50403418 50403415 50403416 50403417
1 1 1 1 1 1 1 1
50403421 50403422 50403423 50403424 50403428 50403425 50403426 50403427
55403412 55403413 55403414 55403415 55403416 55403417
– 6·10
55403422 55403423 55403424 55403425 55403426 55403427
160 250 315 400 500 630 800 1 000 Left end up
50403431 50403432 50403433 50403434 50403438 50403435 50403436 50403437
55403432 55403433 55403434 55403435 55403436 55403437
160 250 315 400 500 630 800 1 000
– 19·12 19·40 20·34 – 26·88 28·67 29·95
Weight (kg) Aluminium Copper
17·94 18·10 18·86 21·79 22·42 23·64 24·95 26·50
– 19·12 19·40 20·34 – 26·88 28·67 29·95
Weight (kg) Aluminium Copper
160 17·94 250 18·10 315 18·86 400 21·79 500 22·42 630 23·64 800 24·95 1 000 26·50 Left end down Rating (A)
1 1 1 1 1 1 1 1
Weight (kg) Aluminium Copper
160 17·94 250 18·10 315 18·86 400 21·79 500 22·42 630 23·64 800 24·95 1 000 26·50 Right end down
Rating (A)
Terminals accept cables up to 150 mm2. For higher ratings attach cable lugs to spreaders provided Left end 50401111 50401112
55403402 55403403 55403404
Rating (A)
Rating (A)
Plastic end feed units
1 1
50403401 50403402 50403403 50403404 50403408 50403405 50403406 50403407
Copper
– 19·12 19·40 20·34 – 26·88 28·67 29·95
Weight (kg) Aluminium Copper
17·94 18·10 18·86 21·79 22·42 23·64 24·95 26·50
– 19·12 19·40 20·34 – 26·88 28·67 29·95
End stops Key : How to select the correct configuration and finish All examples on this page show 4 conductor galvanised lengths No. of conductors and finish is dictated by the red number 0= 4 conductors. Galvanised 2 = 4 conductors. Painted 1= 5 conductors. Galvanised MRF-P 3= 5 conductors. Painted Replace 0 with 1, 2, or 3 if required
1
50403101
1
50403102
Ensure IP 55 protection at the end of the run For right and left feed units 160 – 315 A - for aluminium 250 – 400 A - for copper 400 – 1 000 A - for aluminium 630 – 1 000 A - for copper
37
MR medium rating busbar feed units (continued), in-line bus switcher and reducers
In-line bus switch left hand
Switchboardtransformer feed units left hand
Centre feed unit Switchboardtransformer feed units right hand
In-line bus switch right hand
Dimensions and technical information p. 45-46 MR is fully compliant with IEC 61439-6 (BS EN 61439-6) Rated currents are at an average ambient temperature of 40° C (over and above the required standard of 35° C) IP 55 (according to BS EN 60529) Pack
Feed units (continued)
Cat. Nos.
Pack
In-line bus switches
Cat. Nos.
Centre feed units Feeds a trunking system from an intermediate position along the run. Also used to reduce the volt drop of the line Aluminium
1 1 1 1 1 1 1 1
50401201 50401202 50401203 50401204 50401208 50401205 50401206 50401207
Copper
55401202 55401203 55401204 55401205 55401206 55401207
Rating (A)
160 250 315 400 500 630 800 1 000
Weight (kg) Aluminium Copper
17·27 18·13 18·88 22·06 22·65 23·24 24·02 25·70
– 19·12 19·40 20·34 – 26·88 28·67 29·95
Switchboard-transformer feed units Feed unit for direct connection of the busbar to a switchboard or to the low voltage terminals of a distribution transformer Right hand Aluminium
1 1 1 1 1 1 1 1
50401001 50401002 50401003 50401004 50401008 50401005 50401006 50401007 Aluminium
1 1 1 1 1 1 1 1
50401011 50401012 50401013 50401014 50401018 50401015 50401016 50401017
Copper
55401002 55401003 55401004 55401005 55401006 55401007 Copper
55401012 55401013 55401014 55401015 55401016 55401017
Rating (A)
160 250 315 400 500 630 800 1 000 Left hand Rating (A)
160 250 315 400 500 630 800 1 000
Weight (kg) Aluminium Copper
4·9 5·1 5·3 6·4 6·9 7·5 7·9 8·3
Aluminium
1 1 1 1 1 1 1 1
50401701 50401702 50401703 50401704 50401708 50401705 50401706 50401707
1 1 1 1 1 1 1 1
50401721 50401722 50401723 50401724 50401728 50401725 50401726 50401727
Aluminium
Copper
55401702 55401703 55401704 55401705 55401706 55401707 Left hand Copper
55401722 55401723 55401724 55401725 55401726 55401727
Rating (A)
160 250 315 400 500 630 800 1 000 Rating (A)
160 250 315 400 500 630 800 1 000
Weight (kg) Aluminium Copper
23·54 23·56 23·63 29·32 29·50 29·73 29·80 32·11
– 24·27 24·50 25·38 – 32·17 33·90 35·13
Weight (kg) Aluminium Copper
23·54 23·56 23·63 29·32 29·50 29·73 29·80 32·11
– 24·27 24·50 25·38 – 32·17 33·90 35·13
– 5·7 6·0 9·2 – 9·3 11·4 12·9
Weight (kg) Aluminium Copper
6·0 6·1 6·2 11·3 11·4 11·7 11·8 12·5
– 6·7 7·0 7·8 – 14·2 15·9 17·1
Key : How to select the correct configuration and finish All examples on this page show 4 conductor galvanised lengths No. of conductors and finish is dictated by the red number 0= 4 conductors. Galvanised 2 = 4 conductors. Painted 1= 5 conductors. Galvanised MRF-P 3= 5 conductors. Painted Replace 0 with 1, 2, or 3 if required
38
Allows disconnection of part of a line, while the other is live Right hand
Rating reducers with disconnector and fuse holder also available Contact us on +44 (0) 370 608 9020
MR tap-off boxes – plug-in type up to 32 A
32 A plug-in tap-offs – Empty Energy withstand 400 · 103 A2s Type 1 – Max. power losses 16 W
Cat. Nos. Weight (kg)
Transparent hinged door and 4 mod. DIN rail
Transparent hinged door and 8 mod. DIN rail
50414063
50414064
1·7
1·7
32 A plug-in tap-offs – itted complete with TYPE B MCBs Energy withstand 400 · 103 A2s Type 1 – Max. power losses 16 W Transparent hinged door and 4 mod. DIN rail
Rating
16 A
3 x 1P Cat. Nos. Weight (kg)
3 x (1P + N)
4P
–
–
50414130
–
–
2·29
32 A plug-in tap-offs – itted complete with TYPE C MCBs Energy withstand 400 · 103 A2s Type 1 – Max. power losses 16 W
Rating
3 x 1P
4P
Ready for MCB
Cat. Nos. Weight (kg)
–
50414128
–
16 A
–
2·29
–
Cat. Nos. Weight (kg)
–
50414144
–
32 A
–
2·36
–
Transparent hinged door and 8 mod. DIN rail. Plus 1 x 32 A 3P socket
Cat. Nos. Weight (kg)
–
50414192
–
32 A
–
3·06
–
Transparent hinged door and 8 mod. DIN rail. Plus 2 x 16 A 3P sockets
Cat. Nos. Weight (kg)
–
50414185
50414282
16 A
–
3·23
2·49
Transparent hinged door and 8 mod. DIN rail. Plus 2 x 32 A 3P sockets
Cat. Nos. Weight (kg)
–
–
50414291
32 A
–
–
2·59
Transparent hinged door and 8 mod. DIN rail. Plus 3 x 16 A 2P + E sockets
Cat. Nos. Weight (kg)
50414181
–
50414281
16 A
3·05
–
2·55
Transparent hinged door and 4 mod. DIN rail
Type 2 – Max. power losses 20 W
For dimensions, technical information and mounting instructions see p. 47-48
For other options on tap-off boxes
Contact us on +44 (0) 370 608 9020 39
MR tap-off boxes – plug-in type 32-630 A
MR tap-off boxes from 16 A to 1 000 A can accomodate different protection devices, including fuses, MCBs or MCCBs. Can be operated when energised and under load conditions up to a rating of 32 A due to the integration of an isolating device within the cover. All insulating plastic components comply with the incandescent wire test (BS EN 60695-2-1) and have a V2 self extinguishing degree (UL94). Standard degree of protection is IP 55 without using additional protection kits. For dimensions, technical information and mounting instructions see p. 47-48 Plug-in tap-offs with fuse carriers (or empty) 63-400 A TYPE 4
TYPE 3
Rating
32 A
63 A
100 A
Fuse Carrier
CH10 (Ø10·3 x 38)
TIA / TIS
TCP
Empty
55655051
55055062
55055063
0·85
3·2
3·3
Cat. Nos. Weight (kg)
TYPE 5
400 A (Neutral section 50%)
160 A
250 A
NH 0
NH 0
NH 1
Empty
NH 2
55055055
55055053
50404004
556550571
556550591
556550581
2·9
3·35
3·6
14·9
14·3
15·8
125 A
Plug-in tap-offs itted with DIN rail and transparent hinged window 63-400 A TYPE 4
Can it some MCCBs Rating 63 A
125 A
160 A
400 A
Cat. Nos. Weight (kg) Cat. Nos. Weight (kg) Cat. Nos. Weight (kg) Cat. Nos. Weight (kg)
TYPE 5
Not suitable for MCCBs
4 mod. DIN rail
8 mod. DIN rail
11 mod. DIN rail 55055088
7 mod. DIN rail
11 + 11 mod. DIN rail
–
8 mod. DIN rail 55055086
–
–
–
–
–
3·2
3·6
–
–
–
55055077
55055056
55055068
–
–
–
3·0
3·2
3·6
–
–
50404024
–
–
–
–
–
3·6
–
–
–
–
–
–
–
–
–
550550701
550550711
–
–
–
–
13·4
15·3
Plug-in heavy duty metal tap-offs 63-630 A TYPE 6
TYPE 7
TYPE 8
These PE + FE tap-off boxes have separate terminals for the two parallel earths (casing and conductor) PE = protection earth FE = functional earth
Empty version
With fuse holder
Rating Cat. Nos. Weight (kg) Cat. Nos.
63 A
125 A
160 A
250 A
400 A
630 A
50414001
50414002
50414003
50414004
–
50414005
8·60
8·80
8·80
23
–
25
50414022 NH 00 8·90
50414023 NH 00 9·10
50414024 NH 2 25
50414026 NH 2 33
50414025 NH 3 33
50411622 NH 00 9·70
50411623 NH 00 9·70
50411624 NH 1 30
50411625 NH 2 38
50411646 NH 3 38
50414021 CH22 (Ø22 x 58) 8·75 Weight (kg)
Cat. Nos. With switch disconnector and fuseholder (AC23) Weight (kg)
50411601 NH 000 9·50
For dimensions, technical information and mounting instructions see p. 47-48
1 : Cat. Nos. 55055070 / 55055071 / 55655057 / 55655058 / 55655059 are not available on MR 1 000 A aluminium
40
MR tap-off boxes – plug-in type 125-630 A - fully equipped bolt-on type 630-1 000 A
Plug-in type
Fully equipped tap-offs – toggle handle MCCBs : 25-125 A1 Tap-off rating
125 A
Breaker rating
3 pole MCCB with toggle handle
4 pole MCCB with toggle handle
16 A
55055077M3TF
55055077M4TF
25 A
55055077M3TA
55055077M4TA
40 A
55055077M3TB
55055077M4TB
63 A
55055077M3TC
55055077M4TC
100 A
55055077M3TD
55055077M4TD
125 A
55055077M3TE
55055077M4TE
MCCBs, R type and J type fuse carriers that meet EDF regulations are also available Contact us on +44 (0) 370 608 9020
Tap-off boxes can be supplied with Castel locks Contact us on +44 (0) 370 608 9020
Fully equipped tap-offs – rotary handle MCCBs : 25-630 A1 Tap-off rating
160 A
250 A
630 A
Breaker rating
3 pole MCCB with rotary handle
4 pole MCCB with rotary handle
25 A
50414003M3RA
50414003M4RA
40 A
50414003M3RB
50414003M4RB
63 A
50414003M3RC
50414003M4RC
100 A
50414003M3RD
50414003M4RD
125 A
50414003M3RE
50414003M4RE
160 A
50414003M3RF
50414003M4RF
200 A
50414004M3RG
50414004M4RG
250 A
50414004M3RH
50414004M4RH
400 A
50414005M3RI
50414005M4RI
630 A
50414005M3RJ
50414005M4RJ
Fully equipped tap-offs – with protection and multifunction meters : 63-160 A1 Tap-off rating
160 A
Breaker rating
3 pole MCCB with multifunction meter
63 A
50414003M3MC
100 A
50414003M3MD
125 A
50414003M3ME
160 A
50414003M3MF
1 : For MCCB technical data, see p. 118-125
Bolt-on type Bolt-on tap-offs – with switch disconnector and fuse holder (AC23) Positioned in the joint between straight lengths As this connection affects live conductors, it cannot be carried out when the line is live – the line must be isolated
Tap-off size Busbar rating
630 A Aluminium
800 A 1 000 A
Busbar system 630 A Copper
800 A 1 000 A
Cat. Nos. Weight (kg) Cat. Nos. Weight (kg) Cat. Nos. Weight (kg) Cat. Nos. Weight (kg) Cat. Nos. Weight (kg) Cat. Nos. Weight (kg)
630 A – NH 3 TYPE 9 50401801
800 A – NH 4 TYPE 10 –
1 000 A – NH 4 TYPE 10 –
59 50401802
– 50401804
– –
59 50401803
89 50401805
– 50401806
59 55401801
89 –
89 –
59 55401802
– 55401804
– –
59 55401803
89 55401805
– 55401806
59
89
89
For dimensions, technical information and mounting instructions see p. 47-48
41
MR medium rating busbar fixing accessories
50403711
50632001 + 50632205
50632212 50403712
Dimensions and technical information p. 49 Measuring special dimensions p. 49 The MR series offers a wide range of brackets and fixing accessories that enable quick and simple installation for a wide range of applications. The MR series can be mounted on horizontal or vertical surfaces or mounted directly on to beams. Various spacers, spring suspension hangers and adjustable arms are available to meet the requirements of complex installations Pack
1
1
Cat. Nos.
50632001 50632003
Fixing accessories for general and rising mains applications
Wall fixing bracket Adjustable height and depth arm. Bracket holder can be coupled with MS and MR brackets
50632205
Used when suspension bracket is fixed directly to the wall Weight : 0·05 kg
50403711
For vertical trunking lengths. Suitable for rising mains up to 4 m and for weights up to 300 kg Must be used in conjunction with Cat. Nos. 50632001 or 50632003 1 bracket at the base of the rising main Maximum use distance 4 m Weight : 1·05 kg
50403712
Use 1 hanger every 300 kg (see weight table, p. 52-55) Minimum use distance 4 m Weight : 1·20 kg
Spring suspension hanger for rising main
1
42
Fixing accessories for other applications
Suspension brackets
Suspension hanger for rising main
1
Cat. Nos.
Use 1 bracket every 2 m Weight : 0·55 kg For use with aluminium rated 160, 250, 315 A and copper rated 250, 315, 400 A Weight : 0·60 kg For use with aluminium rated 400, 500, 630, 800 A and copper rated 630, 800, 1 000 A Wall spacer
1
Pack
1 1 1
50632212 50632213 50632214
Length (m)
Weight (kg)
Load on end point
0·45 0·55 0·75
2·80 3·00 3·50
pmax=80 kg pmax=68 kg pmax=50 kg
MR medium rating busbar technical information n General features
n Trunking lengths – 3 m The components and features of MR straight lengths are : • a casing made of Senzimir quality galvanised steel used as protective earth (PE). NOTE : 1 000 A is supplied painted as standard • overall dimensions : 75 to 135 x 196 mm • painted casing available on request (contact us on +44 (0) 370 608 9020) • number of conductors : 4 with the same section (3P + N) with PE made from the casing or 5 when using MR full (3P + N + PE), available in the aluminum or electrolytic copper version with 99.9% purity • conductors insulators are made of fibreglass reinforced plastic material, ensuring a V1 self-extinguishing degree (according to UL 94), in compliance with the glow-wire test according to IEC 60695-2-10 • tap-off outlets with a constant centre distance of 1 m on both sides of the busbar (3 + 3 outlets every 3 m), set up for being connected to plug-in type tap-off boxes. These outlets open and close automatically when inserting or pulling out a tap-off box • ‘monobloc’ electric junction system to connect conductors and PE in a fast and reliable way. The ‘monobloc’ has shear-head bolts with a preset torque setting which ensure good, long-lasting electrical continuity • all components and accessories in the MR range are IP 55 • the whole busbar is flame retardant in compliance with the IEC 60332-3 standard
196 3 000
110
75
90
3 135
160-315 A Al • 250-400 A Cu
135
150
3 135
400-1 000 A Al • 630-1 000 A Cu
n Tap-off outlet cover – IP 55
n Trunking lengths – 1 501 to 2 999 mm with 2 + 2 outlets
375
625
n Trunking lengths – 1 501 to 2 999 mm without outlets 196 75
90
375 0 1 00
400-1 000 A Al 630-1 000 A Cu
110
160-315 A Al • 250-400 A Cu
IP 55
0 1 00 625
135
160-315 A Al 250-400 A Cu 1 : only on 5 conductor
1 501 ≤ A ≤ 2 999
150
L (PE)1 L2 N L3 pe
205
135
196 162
196 162
75
205
n Trunking length – 3 m without outlets
MR is fully compliant with IEC 61439-6 (BS EN 61439-6), specifically, the rated current of Zucchini busbar trunking systems is always rated at the average ambient temperature of 40°C (the Standard requires 35°C), thus offering the market suitably oversized products The busbar casing is made from hot-dipped galvanised sheet steel and forms a high strength outer structure, which also serves as the protective conductor (PE) for the MR version NOTE : 1 000 A is supplied painted as standard The individual conductors are made from either electrolytic copper or electro tin-plated aluminium. Standard MR trunking is supplied with four equal size conductors (TP and N +PE) whereas the optional 5 conductor version includes an additional integral 100% earth bar (TP and N +E) The degree of protection is IP 55 throughout the system The normal recommended fixing centres for the MR range is 2·0 m The jointing of MR lengths is done by overlapping two lengths and fastening the special locating screws. The ‘monobloc’ joint is then tightened by a double headed shear bolt to complete the electrical connection. A joint cover is then positioned to complete the joint
400-1 000 A Al • 630-1 000 A Cu
n Trunking lengths – 3 m with 5 outlets on one side only
500 500 500
375
n Trunking lengths – 1 000 to 1 500 mm with 1 + 1 outlets
500 625
375 625
All dimensions (mm) are nominal
43
MR medium rating busbar technical information (continued) n Double elbows Standard dimensions (300 + 300 + 300 mm) 90° as standard. Other angles available on request. IP 55 quick connection
196
205
n Trunking lengths – 600 to 1 500 mm without outlets
600 ≤ A ≤ 1 500
Bespoke dimensions Measure from the long casing to the axis of the elbow Double horizontal elbow Right + left Left + right
75
90
110
(C)
(A)
(C)
(B)
(A)
135
150
160-315 A Al • 250-400 A Cu
400-1 000 A Al • 630-1 000 A Cu
Bespoke dimensions (mm) Min 250 ≤
Double vertical elbow Right + left
158
Max ≤ 900
Left + right
200
(B)
244
244
n Trunking lengths with S120 fire barrier
A, B, C
244 630
160-315 A Al 250-400 A Cu
400-1 000 A Al 630-1 000 A Cu
A
00 ≥2
Bespoke dimensions (mm) Min 300 ≤
n Single elbows – standard dimensions (300 + 300 mm)
A, B, C
Max ≤ 900
Vertical + horizontal elbows RH + RH RH + LH
(A)
(B)
90° as standard. Other angles available on request. IP 55 quick connection Horizontal elbow RH
LH
300
300
LH + RH
LH + LH
(C)
Vertical elbow RH
LH 300
300
Bespoke dimensions (mm) Min 300 ≤
Max ≤ 900
Horizontal + vertical elbows RH + RH
RH + LH
LH + RH
LH + LH
(A)
(B)
Bespoke dimensions Measure from the long casing to the axis of the elbow (see measuring bespoke dimensions p. 49)
A, B, C
Special horizontal elbow A
B
Bespoke dimensions (mm) Min
Max
250 ≤
A
≤ 900
250 ≤
B
≤ 900
(C)
Special vertical elbow A
B
Bespoke dimensions (mm) Min
Max
300 ≤
A
≤ 900
300 ≤
B
≤ 900 Bespoke dimensions (mm) Min
All dimensions (mm) are nominal
44
300 ≤
A, B, C
Max ≤ 900
n Horizontal tee
n Metal end feed units
Standard dimensions (300 + 300 + 300 mm)
600 850
600
250
Left hand – male tee
Left hand – female tee
250
290
290
40
850
40
400
196
Right hand – female tee
400
During shipment the stump is positioned in the box to reduce its bulk Take it out and screw it in the position illustrated here Opening on the base cable entry : 180 x 290 mm. For plates and holes dimensions, see p. 46 for the switchboard feed unit with the same rating
Right hand – male tee
RH
LH
n End feed unit with AC23 switch disconnector
Bespoke dimensions (B)
(A)
(C)
B
Dimensions (mm) 1
Bespoke dimensions (mm) Min 250 ≤
250
Max
A
≤ 900
550
2 1050
B
350
450
C
280
300
D
800
1300
D
C
A, B, C
A
n Crossover – standard dimensions (300 + 300 + 300 + 300 mm)
Cable entry dimensions (mm) 1 180 x 270
2 210 x 380
300
300
300
RH down
LH up
LH down
300
RH up
n End feed units Cable connection : max. sect. (3 x 120 mm2 + 1 x 70 mm2) or 3 x 150 mm2, max PG 48 550 100
100 240
400
350
350
RH
n Centre feed units 600
290
200
240
550
200
LH Cable entry
All dimensions (mm) are nominal
45
MR medium rating busbar technical information (continued) n End stop
n In-line bus switch
Ensures IP 55 protection at the end of the run (EN 60529)
D A
240
B
175
40
n Switchboard-transformer feed units
140
250
C
RH
65
250 140
Dimensions (mm) Type 1
Type 1
Type 2
65 Ø9
Ø11
30 75
Ø11
Type 2
550
A
350
B
450
280
C
300
1 050
D
1 550
20
20
280
125 125
340
50 90
Dimensions (mm) Al Type 1
Type 2
Cu
160 A
250 A
250 A
315 A
315 A
400 A
400 A
630 A
500 A
800 A
630 A
1 000 A
800 A
–
1 000 A
–
All dimensions (mm) are nominal
46
LH
RH
LH
1 050
n Tap-off boxes
Type 7 250 A
Type 1
640
216
3601
100
331
1 : 445 mm with handles 260
Type 8 400-630 A 374
790
216
4001
100
Type 2
1 : 486 mm with handles
Type 9 630 A
350
750
280
Type 3 32 A 130
200
400
45
345
Type 4 63-160 A 400
115
Type 10 800-1 000 A 1 050
450
250
300
Type 51 250-400 A 200
542
265
360
Type 6 63-160 A 185
230
454
225
1 : Cat. Nos. 55055070 / 55055071 / 55655057 / 55655058 / 55655059 are not available on MR 1 000 A aluminium
All dimensions (mm) are nominal
47
MR medium rating busbar mounting tap-offs n Trunking length with 3 outlets
Rising main
Edgeways
1
2
2
3
4
3
4
5
6
5
6
7
8
1
1
2
3
4
5
6
7
8
1 5
1
9
10
1
2
3
4
5
6
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2 6
2
3 7
3
4
5
6
1
2
3
Numbers in squares refer to the tap-off box type 4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
7
8
1
2
3
4
5
6
4 8
9
9
10
n Trunking length with 5 outlets
Rising main
Edgeways
9
10
2
3
4
4
5
6
2
3 5
2
3
4
3
4
5
6
5
6
2
1 1 1
1
6
1
2
1
2
3
1
2
3
3
4
4
5
6
4
5
6
5
6 1
2
3
4
5
6
1
2
3
1
2
3
6
4
5
6
non-usable
1
2
3
4
5
6
4
5
Numbers in squares refer to the tap-off box type
non-usable
1
2
3
1
2
3
4
5
6
4
5
6
9
9 10
Note : in busbar with 5 outlets, Type 5 tap-off boxes (see p. 47) do not allow the possibility of installing other boxes in the next outlet
48
MR medium rating busbar technical information n Suspension brackets
n Measuring bespoke dimensions
146
A
Straight lengths Always measure from the long side of the casing as illustrated
143
172
206
112
260
208
146
260
20 148
B
C L
Cat. Nos.
A–B
C
A
50632001
B
50632003
C
50632205
n Wall fixing bracket Elbows Measure from the long casing to the axis of the elbow
450 / 550 / 750
40
500
60
170
11 x 25
25 x 7
A
A
B
B
B
B
50
A
A
All dimensions (mm) are nominal
49
MR medium rating busbar how to design the system
1 Use end feed unit LH – left hand This gives the neutral bar positioning on the right of elements and the tap-off box with cable entry at the base
2 Use the vertical hanger for rising main as a function of the run weight For vertical lengths less than 4 metres fit on the base of the busbar a vertical bracket (Cat. No. 50403711) for longer lengths use vertical suspension hanger (Cat. No. 50403712) every 300 kg of rising main
L1 PE L2 N L3
7
6
3 Use standard suspension brackets with spacer 40 mm every 2 m of the rising main
8 3
4 Use straight lengths with plug outlets on one side
8 5
5 Use the straight length with fire barrier to maintain the fire resistance of the floor Please specify the position of the internal fire barrier before placing an order (see p. 44)
8
8 6 The tap-off box can be installed on the joint between the elements or on the outlets
4
7 At the end of the rising main use the end cover IP 55 Before mounting the end cover remove the monobloc prefitted on the last element of rising main 2 8 Maintain the plug outlet covers to guarantee the degree of protection IP 55 to the run
1
50
MR medium rating busbar how to create codes for SB/MR adaptors
MR
1 200 600
250
400
350
40
SB Left hand
290
L1 PE L2 N L3
Right hand
SB L1 PE L2 N L3
5 0
4
0
0
2
2
1
Conductors 0 Aluminium 5 Copper Case 0 1 2 3
Galvanised Full galvanised Painted Full painted
Type 2 Right 3 Left
Rating 1 160 A 2 250 A 3 315 A 4 400 A 5 630 A 6 800 A 7 1 000 A 8 500 A
NOTE SB is a previous range of Zucchini medium rating busbar
Example code 50400226
means Aluminium Galvanised Type RH 800 A
55420235
means Copper Full galvanised Type LH 630 A
All dimensions (mm) are nominal
51
MR medium rating busbar – 4 conductor (aluminium) technical data
Complies to : IEC 61439-6 (BS EN 61439-6) Suitable for the following climates : Constant humid climate (IEC 60068 2 – 11) Cyclical humid climate (IEC 60068 2 – 30)
3L+N+PE (Aluminium) Rated current In (A) Operational voltage Ue (V) Insulation voltage Ui (V) Frequency ƒ (Hz) Rated shortcircuit current withstand for 3-phase fault (1 s) Icw (kA)rms Specific Energy withstand for 3-phase fault I2t (M A2s) Peak current Ipk (kA) Rated short-time current for single-phase fault Ph-N(1 s) Icw (kA)rms Peak current for single-phase fault Ph-N Ipk (kA) Rated short-time current single-phase fault Ph-PE (1 s) Icw (kA)rms Peak current single-phase fault Ph-PE Ipk (kA) Phase resistance at 20°C R20 (mΩ/m) Phase resistance at thermal conditions (In; 40°C) Rt (mΩ/m) Phase reactance (50 Hz) X (mΩ/m) Neutral resistance at 20°C Rn20 (mΩ/m) Neutral reactance (50 Hz) Xn (mΩ/m) Resistance of the protective bar RPE (mΩ/m) Reactance of the protective bar (50 Hz) XPE (mΩ/m) Resistance of the phase-Pe fault loop RPh-Pe fault loop (mΩ/m) Reactance of the phase-Pe fault loop (50 Hz) XRPh-Pe fault loop (mΩ/m) Resistance of the phase-neutral fault loop RPh-N fault loop (mΩ/m) Reactance of the phase-neutral fault loop (50 Hz) XRPh-N fault loop (mΩ/m) ∆v (V/m/A)10-6 cosϕ = 0·70 ∆v (V/m/A)10-6 cosϕ = 0·75 Voltage “k” drop coeff. with ∆v (V/m/A)10-6 cosϕ = 0·80 Voltage “k” drop coeff. with distribuited load (k) ∆v (V/m/A)10-6 cosϕ = 0·85 distributed load (k) ∆v (V/m/A)10-6 cosϕ = 0·90 ∆v (V/m/A)10-6 cosϕ = 0·95 ∆v (V/m/A)10-6 cosϕ = 1·00 Losses for the Joule effect at nominal current P (W/m) Fire load (kWh/m) Weight (kg/m) Overall dimensions of the busbar L x H (mm) Degree of protection (IEC 60529) IP IK code IEC 60068-2-62 IK
160 1 000 1 000 50/60 151 23 30 91 15 91 15 0·492 0·665 0·260 0·492 0·260 0·341 0·220 1·006 0·480 1·157 0·480 564 581 596 608 616 617 576 51 1·3 7·4 75 x 196 52-55 10
250 1 000 1 000 50/60 251 63 53 151 30 151 30 0·328 0·443 0·202 0·328 0·202 0·341 0·220 0·784 0·414 0·771 0·422 394 404 412 418 422 419 384 83 1·3 7·7 75 x 196 52-55 10
315 1 000 1 000 50/60 251 63 53 151 30 151 30 0·197 0·266 0·186 0·197 0·186 0·341 0·220 0·607 0·396 0·463 0·406 276 279 281 281 277 269 230 79 1·3 8·4 75 x 196 52-55 10
400 1 000 1 000 50/60 25 625 53 15 30 15 30 0·120 0·163 0·130 0·120 0·130 0·283 0·180 0·445 0·333 0·283 0·310 179 180 180 179 176 169 141 78 1·8 10·7 135 x 196 52-55 10
500 1 000 1 000 50/60 30 900 63 18 36 18 36 0·077 0·104 0·110 0·077 0·110 0·283 0·180 0·387 0·333 0·181 0·290 131 130 129 127 122 115 90 78 1·8 12·3 135 x 196 52-55 10
630 1 000 1 000 50/60 36 1 296 76 22 45 22 45 0·060 0·081 0·097 0·060 0·097 0·283 0·180 0·364 0·283 0·141 0·277 109 108 107 104 100 93 70 97 1·8 13·8 135 x 196 52-55 10
800 1 000 1 000 50/60 36 1 296 76 22 45 22 45 0·052 0·070 0·096 0·052 0·096 0·283 0·180 0·353 0·275 0·121 0·276 102 100 98 95 91 83 60 134 1·8 14·7 135 x 196 52-55 10
1 000 690 690 50/60 30 900 63 18 36 18 36 0·037 0·073 0·076 0·037 0·076 0·283 0·180 0·336 0·273 0·093 0·186 90 88 85 82 77 69 46 160 1·8 15·9 135x 196 52-55 10
1 : Values for 0·1 s
Temperature rating schedule Mean room temperature (°C) K1 factor
15
20
25
30
35
40
45
50
55
60
1·15
1·12
1·08
1·05
1·025
1
0·975
0·95
0·93
0·89
Multiplier coefficient of nominal rating for room temperature values different from 40°C
52
MR medium rating busbar – 4 conductor (copper) technical data
Complies to : IEC 61439-6 (BS EN 61439-6) Suitable for the following climates : Constant humid climate (IEC 60068 2 – 11) Cyclical humid climate (IEC 60068 2 – 30)
3L+N+PE (Copper) In (A) Rated current Ue (V) Operational voltage Ui (V) Insulation voltage ƒ (Hz) Frequency Icw (kA)rms Rated shortcircuit current withstand for 3-phase fault (1 s) I2t (M A2s) Specific Energy withstand for 3-phase fault Ipk (kA) Peak current Icw (kA)rms Rated short-time current for single-phase fault Ph-N(1 s) Ipk (kA) Peak current for single-phase fault Ph-N Icw (kA)rms Rated short-time current single-phase fault Ph-PE (1 s) Ipk (kA) Peak current single-phase fault Ph-PE R20 (mΩ/m) Phase resistance at 20°C Rt (mΩ/m) Phase resistance at thermal conditions (In; 40°C) X (mΩ/m) Phase reactance (50 Hz) Rn20 (mΩ/m) Neutral resistance at 20°C Xn (mΩ/m) Neutral reactance (50 Hz) RPE (mΩ/m) Resistance of the protective bar XPE (mΩ/m) Reactance of the protective bar (50 Hz) RPh-Pe fault loop (mΩ/m) Resistance of the phase-Pe fault loop XRPh-Pe fault loop (mΩ/m) Reactance of the phase-Pe fault loop (50 Hz) RPh-N fault loop (mΩ/m) Resistance of the phase-neutral fault loop XRPh-N fault loop (mΩ/m) Reactance of the phase-neutral fault loop (50 Hz) ∆v (V/m/A)10-6 cosϕ = 0·70 ∆v (V/m/A)10-6 cosϕ = 0·75 ∆v (V/m/A)10-6 cosϕ = 0·80 Voltage “k” drop coeff. with Voltage “k” drop coeff. with ∆v (V/m/A)10-6 cosϕ = 0·85 distribuited load (k) distributed load (k) ∆v (V/m/A)10-6 cosϕ = 0·90 ∆v (V/m/A)10-6 cosϕ = 0·95 ∆v (V/m/A)10-6 cosϕ = 1·00 P (W/m) Losses for the Joule effect at nominal current (kWh/m) Fire load (kg/m) Weight L x H (mm) Overall dimensions of the busbar IP Degree of protection (IEC 60529) IK IK code IEC 60068-2-62
250 1 000 1 000 50/60 251 63 53 151 30 151 30 0·237 0·320 0·205 0·237 0·205 0·336 0·220 0·657 0·425 0·558 0·425 321 326 329 329 327 319 277 60 1·3 9·3 75 x 196 52-55 10
315 1 000 1 000 50/60 251 63 53 151 30 151 30 0·180 0·243 0·188 0·180 0·188 0·336 0·220 0·579 0·408 0·423 0·408 263 265 266 264 260 251 210 72 1·3 10·2 75 x 196 52-55 10
400 1 000 1 000 50/60 301 90 63 181 36 181 36 0·096 0·129 0·129 0·096 0·129 0·336 0·220 0·466 0·349 0·225 0·349 158 158 157 154 149 141 112 62 1·3 13·3 135 x 196 52-55 10
630 1 000 1 000 50/60 36 1 296 76 22 45 22 45 0·061 0·082 0·122 0·061 0·122 0·279 0·180 0·361 0·302 0·143 0·302 125 123 120 116 110 101 71 98 1·8 18·2 135 x 196 52-55 10
800 1 000 1 000 50/60 36 1 296 76 22 45 22 45 0·040 0·053 0·122 0·040 0·122 0·279 0·180 0·332 0·302 0·093 0·302 108 105 100 95 88 77 46 103 1·8 23·9 135 x 196 52-55 10
1 000 1 000 1 000 50/60 36 1 296 76 22 45 22 45 0·032 0·043 0·120 0·032 0·120 0·279 0·180 0·322 0·300 0·074 0·300 100 96 92 86 79 68 37 128 1·8 27·9 135 x 196 52-55 10
1 : Values for 0·1 s
Temperature rating schedule Mean room temperature (°C) K1 factor
15
20
25
30
35
40
45
50
55
60
1·15
1·12
1·08
1·05
1·025
1
0·975
0·95
0·93
0·89
Multiplier coefficient of nominal rating for room temperature values different from 40°C
53
MR medium rating busbar – five conductor (aluminium) technical data
Complies to : IEC 61439-6 (BS EN 61439-6) Suitable for the following climates : Constant humid climate (IEC 60068 2 – 11) Cyclical humid climate (IEC 60068 2 – 30)
3L+N 100% +PE 100% (Aluminium) Rated current In (A) Operational voltage Ue (V) Insulation voltage Ui (V) Frequency ƒ (Hz) Rated shortcircuit current withstand for 3-phase fault (1 s) Icw (kA)rms Specific Energy withstand for 3-phase fault I2t (M A2s) Peak current Ipk (kA) Rated short-time current for single-phase fault Ph-N(1 s) Icw (kA)rms Peak current for single-phase fault Ph-N Ipk (kA) Rated short-time current single-phase fault Ph-PE (1 s) Icw (kA)rms Peak current single-phase fault Ph-PE Ipk (kA) Phase resistance at 20°C R20 (mΩ/m) Phase resistance at thermal conditions (In; 40°C) Rt (mΩ/m) Phase reactance (50 Hz) X (mΩ/m) Neutral resistance at 20°C Rn20 (mΩ/m) Neutral reactance (50 Hz) Xn (mΩ/m) Resistance of the protective bar RPE (mΩ/m) Reactance of the protective bar (50 Hz) XPE (mΩ/m) Resistance of the phase-Pe fault loop RPh-Pe fault loop (mΩ/m) Reactance of the phase-Pe fault loop (50 Hz) XRPh-Pe fault loop (mΩ/m) Resistance of the phase-neutral fault loop RPh-N fault loop (mΩ/m) Reactance of the phase-neutral fault loop (50 Hz) XRPh-N fault loop (mΩ/m) ∆v (V/m/A)10-6 cosϕ = 0·70 ∆v (V/m/A)10-6 cosϕ = 0·75 Voltage “k” drop coeff. with ∆v (V/m/A)10-6 cosϕ = 0·80 Voltage “k” drop coeff. with distribuited load (k) ∆v (V/m/A)10-6 cosϕ = 0·85 distributed load (k) ∆v (V/m/A)10-6 cosϕ = 0·90 ∆v (V/m/A)10-6 cosϕ = 0·95 ∆v (V/m/A)10-6 cosϕ = 1·00 Losses for the Joule effect at nominal current P (W/m) Fire load (kWh/m) Weight (kg/m) Overall dimensions of the busbar L x H (mm) Degree of protection (IEC 60529) IP IK code IEC 60068-2-62 IK
160 1 000 1 000 50/60 151 23 30 91 15 91 15 0·492 0·665 0·260 0·492 0·260 0·202 0·119 0·866 0·379 1·157 0·520 564 581 596 608 616 617 576 51 1·3 7·6 75 x 196 52-55 10
250 1 000 1 000 50/60 251 63 53 151 30 151 30 0·328 0·443 0·202 0·328 0·202 0·167 0·105 0·611 0·307 0·771 0·404 394 404 412 418 422 419 384 83 1·3 8·0 75 x 196 52-55 10
315 1 000 1 000 50/60 251 63 53 151 30 151 30 0·197 0·266 0·186 0·197 0·186 0·125 0·101 0·391 0·287 0·463 0·372 276 279 281 281 277 269 230 79 1·3 8·9 75 x 196 52-55 10
400 1 000 1 000 50/60 25 625 53 15 30 15 30 0·120 0·163 0·130 0·120 0·130 0·084 0·075 0·247 0·205 0·283 0·260 179 180 180 179 176 169 141 78 1·8 11·4 135 x 196 52-55 10
500 1 000 1 000 50/60 30 900 63 18 36 18 36 0·077 0·104 0·110 0·077 0·110 0·060 0·068 0·164 0·178 0·181 0·220 131 130 129 127 122 115 90 78 1·8 13·5 135 x 196 52-55 10
630 1 000 1 000 50/60 36 1 296 76 22 45 22 45 0·060 0·081 0·097 0·060 0·097 0·050 0·063 0·131 0·160 0·141 0·194 109 108 107 104 100 93 70 97 1·8 15·2 135 x 196 52-55 10
800 1 000 1 000 690 1 000 690 50/60 50/60 36 30 1 296 900 76 63 22 18 45 36 22 22 45 45 0·052 0·039 0·070 0·053 0·096 0·093 0·052 0·039 0·096 0·093 0·044 0·034 0·063 0·061 0·113 0·087 0·159 0·154 0·121 0·093 0·192 0·186 102 90 100 88 98 85 95 82 91 77 83 69 60 46 134 160 1·8 1·8 16·4 17·9 135 x 196 135 x 196 52-55 52-55 10 10
1 : Values for 0·1 s
Temperature rating schedule Mean room temperature (°C) K1 factor
15
20
25
30
35
40
45
50
55
60
1·15
1·12
1·08
1·05
1·025
1
0·975
0·95
0·93
0·89
Multiplier coefficient of nominal rating for room temperature values different from 40°C
54
MR medium rating busbar – five conductor (copper) technical data
Complies to : IEC 61439-6 (BS EN 61439-6) Suitable for the following climates : Constant humid climate (IEC 60068 2 – 11) Cyclical humid climate (IEC 60068 2 – 30)
3L+N 100% +PE 100% (Copper) In (A) Rated current Ue (V) Operational voltage Ui (V) Insulation voltage ƒ (Hz) Frequency Icw (kA)rms Rated shortcircuit current withstand for 3-phase fault (1 s) I2t (M A2s) Specific Energy withstand for 3-phase fault Ipk (kA) Peak current Icw (kA)rms Rated short-time current for single-phase fault Ph-N(1 s) Ipk (kA) Peak current for single-phase fault Ph-N Icw (kA)rms Rated short-time current single-phase fault Ph-PE (1 s) Ipk (kA) Peak current single-phase fault Ph-PE R20 (mΩ/m) Phase resistance at 20°C Rt (mΩ/m) Phase resistance at thermal conditions (In; 40°C) X (mΩ/m) Phase reactance (50 Hz) Rn20 (mΩ/m) Neutral resistance at 20°C Xn (mΩ/m) Neutral reactance (50 Hz) RPE (mΩ/m) Resistance of the protective bar XPE (mΩ/m) Reactance of the protective bar (50 Hz) RPh-Pe fault loop (mΩ/m) Resistance of the phase-Pe fault loop XRPh-Pe fault loop (mΩ/m) Reactance of the phase-Pe fault loop (50 Hz) RPh-N fault loop (mΩ/m) Resistance of the phase-neutral fault loop XRPh-N fault loop (mΩ/m) Reactance of the phase-neutral fault loop (50 Hz) ∆v (V/m/A)10-6 cosϕ = 0·70 ∆v (V/m/A)10-6 cosϕ = 0·75 ∆v (V/m/A)10-6 cosϕ = 0·80 Voltage “k” drop coeff. with Voltage “k” drop coeff. with ∆v (V/m/A)10-6 cosϕ = 0·85 distribuited load (k) distributed load (k) ∆v (V/m/A)10-6 cosϕ = 0·90 ∆v (V/m/A)10-6 cosϕ = 0·95 ∆v (V/m/A)10-6 cosϕ = 1·00 P (W/m) Losses for the Joule effect at nominal current (kWh/m) Fire load (kg/m) Weight L x H (mm) Overall dimensions of the busbar IP Degree of protection (IEC 60529) IK IK code IEC 60068-2-62
250 1 000 1 000 50/60 251 63 53 151 30 151 30 0·237 0·320 0·205 0·237 0·205 0·139 0·106 0·460 0·311 0·558 0·311 321 326 329 329 327 319 277 60 1·3 10·0 75 x 196 52-55 10
315 1 000 1 000 50/60 251 63 53 151 30 151 30 0·180 0·243 0·188 0·180 0·188 0·117 0·101 0·360 0·289 0·423 0·289 263 265 266 264 260 251 210 72 1·3 11·1 75 x 196 52-55 10
400 1 000 1 000 50/60 301 90 63 181 36 181 36 0·096 0·129 0·129 0·096 0·129 0·075 0·081 0·204 0·210 0·225 0·210 158 158 157 154 149 141 112 62 1·3 14·9 135 x 196 52-55 10
630 1 000 1 000 50/60 36 1 296 76 22 45 22 45 0·061 0·082 0·122 0·061 0·122 0·050 0·073 0·132 0·195 0·143 0·195 125 123 120 116 110 101 71 98 1·8 20·8 135 x 196 52-55 10
800 1 000 1 000 50/60 36 1 296 76 22 45 22 45 0·040 0·053 0·122 0·040 0·122 0·035 0·073 0·088 0·195 0·093 0·195 108 105 100 95 88 77 46 103 1·8 27·9 135 x 196 52-55 10
1 000 1 000 1 000 50/60 36 1 296 76 22 45 22 45 0·032 0·043 0·120 0·032 0·120 0·028 0·072 0·071 0·192 0·074 0·192 100 96 92 86 79 68 37 128 1·8 32·9 135 x 196 52-55 10
1 : Values for 0·1 s
Temperature rating schedule Mean room temperature (°C) K1 factor
15
20
25
30
35
40
45
50
55
60
1·15
1·12
1·08
1·05
1·025
1
0·975
0·95
0·93
0·89
Multiplier coefficient of nominal rating for room temperature values different from 40°C
55
MR medium rating busbar determining the operating current of a busbar
In order to determine the correct busbar rating, the current must be established using the following criteria : • type of load inputs – three phase or single-phase • type of circuit input – from one end, from both ends, central input, etc. • nominal input voltage • number, power and cosϕ of loads which are to be fed by the busbar • load diversity factor • load use nominal factor • assumed short circuit current at the input point • room temperature • type of busbar installation (edgeways, flat or vertical) When using a three phase power supply, the operating current is determined by the following formula : Ib = PTOT • α • β • d (A) √3 • Ue • cosϕ medium Where : Ib α β d PTOT Ue cosϕ medium
operating current (A) load diversity factor (.) load use factor (.) feed factor (.) sum of the total active power of installed loads (W) operating voltage (V) average load power factor (.)
15
k, thermal correction factor (.)
20
25
30
35
1·15 1·12 1·08 1·05 1·025
40 1
45
50
55
Int ≥ Ib
I
nt
60
0·975 0·95 0·93 0·89
Finally, the following should be considered for the most appropriate busbar choice : = k1 • In
where Int represents the maximum current loaded by a busbar for an indefinite time at the specified room temperature
k• Ib • L ∆v% = 2b •
• 100 Vn
Defined : Ib Vn L ∆v% b k
b=1
The ‘d’ input factor has a value of 1 when the busbar is fed from one end only. The value is 1/2 if fed from the centre or if it is fed from each end Once the operating current has been determined, choose the busbar with a rated current immediately higher than the one calculated All Zucchini products have been designed and tested for an average room temperature of 40°C; should they be installed in rooms with average daily temperatures different from 40°C, the rated current of the busbar should be multiplied by a k1 factor that is greater than the unit for temperatures lower than 40°C, and lower than the unit if the room temperature is higher than 40°C Room temperature (°C)
Voltage drop If the length of the line is particularly long (>100m) it is necessary to check the voltage drop (hereinafter specified as v.d.). If the installation is a three phase system and the power factor is not lower than cos = 0.7 the v.d. may be calculated with the coefficients of the voltage drop specified in the technical data table
b=2
b=4 b=4 b=8
= the current that supplies the busbar (A) = the voltage power supply of the busbar (V) = the length of the busbar (m) = the voltage drop percentage = the distribution factor of the current = corresponding voltage drop factor a cosϕ (V/m/A) (see technical data table, p. 52-55) The current distribution factor “b” depends on how the circuit is fed and on the distribution of the electric loads along the busbar : Supplies at one end and load at the end of the line
Ib
Supplies at one end and with load evenly distributed
Ib
Supplies at both ends and with load evenly distributed
Ib
Central supply with loads at both ends
Ib
L
L
Ib
L
Ib 2
Central supply with load distributed evenly
Ib 2
L Ib
Example : MR 400 A Al for riser mains feed Ib b=1 k = 179 Cosϕ L Vn
= 315 A operating current = supply from one end = see technical data table, p. 52-55 = 0·85 = 30 m line length = 400 V operating voltage ∆v% = 1x
179 • 10-6 • 315 • 30 x100 = 0·42% 400
Short circuit current The short circuit current value ICW that can be supported by Zucchini busbar trunking systems allows for both electrodynamic stress and thermal energy dissipated during the fault The busbars must be able to sustain the short circuit current for the entire duration of the fault – i.e. for the time required for the protective device (circuit breaker) to start operating, cutting off the metal continuity and extinguishing the electric arc Joule effect losses Losses due to the Joule effect are essentially caused by the electrical resistance of the busbar. Lost energy is transformed into heat and contributes to the heating of the conduit Three phase rating P = 3 • Rt • Ib2 • 10-3(W/m)
Single phase rating P = 2 • Rt • Ib2 • 10-3(W/m)
56
ZUCCHINI TS TROLLEY SYSTEM BUSBAR
The Zucchini TS busbar range is ideal for supplying 25 to 160 A three phase loads to moving devices such as overhead cranes, traversing motors, assembly lines, etc. Suitable for straight and curved sections with horizontal route changes, TS busbar is quick and easy to install using an electrical terminal junction and a wide range of supporting accessories. Versions include : • 3L+N+PE (5 conductors) • 3L+PE (4 conductors)
To find out more call our technical support team on +44 (0) 370 608 9020
57
ZUCCHINI SCP Offering maximum versatility in demanding commercial and industrial enviroments, SCP busbar is used to transport and distribute high power from 630 to 6300 A and is a popular choice for rising mains.
Compact design combined with powerful performance makes Zucchini SCP the intelligent choice for demanding installations 58
super compact high power busbar Zucchini SCP busbar trunking systems are ideal for the distribution of high power in industrial, commercial and service sector installations. Flexible and safe, SCP is continually developed to offer maximum versatility for all power applications, in any type of environment. The high power, super compact Zucchini busbar range provides a complete solution whether connecting power supply stations or transformers to the main panel board, or transporting and distributing power around the building, including rising mains applications.
SAFETY Compact dimensions enhance SCP’s resistance to short circuit stresses. Voltage drops can be controlled to reduce the impedance of the circuit and enable installation of high power electrical systems in confined spaces.
MAINTENANCE With the exception of the compulsory periodic inspections required by Standard BS 7671, the range is designed to be virtually maintenance free.
FLEXIBILITY Plug-in tap-off boxes provide connection and power supply of three phase loads from 63 to 1250 A. Thanks to the galvanised metal sheet construction, the boxes are suitable for heavy loads and for shielding the electromagnetic fields generated by the passage of current.
59
ZUCCHINI SCP fast, simple installation saves time and money on site INSTALLATION SIMPLICITY Designed to work perfectly in conjunction with Legrand cast resin transformers, the SCP busbar range offers quick, reliable assembly with a vast combination of accessories for maximum flexibility. Conductors are available in a choice of copper or aluminium.
PLANNING SIMPLICITY A comprehensive range of standard products is further enhanced by Legrand’s technical expertise and ability to create bespoke solutions tailored to any requirement. The SCP range can be manufactured in standard, clean earth or 200% neutral versions.
60
Pre-installed monobloc for fast, rigid and reliable connections
Trunking lengths available with aluminium or copper conductors and in single or double sided versions
SWITCHBOARD TRANSFORMER FEED UNIT
Self-shearing bolts ensure the correct torque is applied at the joint
HORIZONTAL ELBOW
VERTICAL ELBOW
JOINT
TRUSTED BY LEADING DEVELOPERS Zucchini SCP high power busbar meets the quality and specification requirements of leading property developers and is installed in prestigious projects across the world.
61
SCP super compact busbar aluminium conductors
TRUNKING LENGTHS Feeder lengths
Rating (A) Standard 3 m
Bespoke dimensions 1 to 1路5 m Bespoke dimensions 1路5 to 2 m Bespoke dimensions 2 to 2路5 m Bespoke dimensions 2路5 to 3 m
630
60280100P
60280170P
60280120P
60280180P
60280150P
800
60280101P
60280171P
60280121P
60280181P
60280151P
1 000
60280102P
60280172P
60280122P
60280182P
60280152P
1 250
60280104P
60280174P
60280124P
60280184P
60280154P
1 600
60280106P
60280176P
60280126P
60280186P
60280156P
2 000
60280107P
60280177P
60280127P
60280187P
60280157P
2 500
60390104P
60390174P
60390124P
60390184P
60390154P
3 200
60390106P
60390176P
60390126P
60390186P
60390156P
4 000
60390107P
60390177P
60390127P
60390187P
60390157P
ELBOWS AND TEES Horizontal elbows Rating (A)
Double horizontal elbows
Vertical elbows
Standard dimensions
Bespoke dimensions
Standard dimensions
Bespoke dimensions
Right hand
Right hand
Right hand
Right hand
Left hand
Left hand
Left hand
Bespoke dimensions Left + right hand Right + left hand
Left hand
630
60280300P 60280310P
60280320P
60280330P 60280400P 60280410P
60280420P 60280430P
60280350P
60280340P
800
60280301P 60280311P
60280321P
60280331P 60280401P 60280411P
60280421P 60280431P
60280351P
60280341P
1 000
60280302P 60280312P
60280322P
60280332P 60280402P 60280412P
60280422P 60280432P
60280352P
60280342P
1 250
60280304P 60280314P
60280324P
60280334P 60280404P 60280414P
60280424P 60280434P
60280354P
60280344P
1 600
60280306P 60280316P
60280326P
60280336P 60280406P 60280416P
60280426P 60280436P
60280356P
60280346P
2 000
60280307P 60280317P
60280327P
60280337P 60280407P 60280417P
60280427P 60280437P
60280357P
60280347P
2 500
60390304P 60390314P
60390324P
60390334P 60390404P 60390414P
60390424P 60390434P
60390354P
60390344P
3 200
60390306P 60390316P
60390326P
60390336P 60390406P 60390416P
60390426P 60390436P
60390356P
60390346P
4 000
60390307P 60390317P
60390327P
60390337P 60390407P 60390417P
60390427P 60390437P
60390357P
60390347P
CONNECTION INTERFACES Connection interfaces Rating (A)
62
Standard dimensions
Connection interfaces + horizontal elbows
Bespoke dimensions
Bespoke dimensions
Type 1 male
Type 2 female
Type 1 male
Type 2 female
Type 1 female
Type 2 female
Type 3 male
Type 4 male
630
60281010P
60281000P
60281030P
60281020P
60281300P
60281310P
60281320P
60281330P
800
60281011P
60281001P
60281031P
60281021P
60281301P
60281311P
60281321P
60281331P
1 000
60281012P
60281002P
60281032P
60281022P
60281302P
60281312P
60281322P
60281332P
1 250
60281014P
60281004P
60281034P
60281024P
60281304P
60281314P
60281324P
60281334P
1 600
60281016P
60281006P
60281036P
60281026P
60281306P
60281316P
60281326P
60281336P
2 000
60281017P
60281007P
60281037P
60281027P
60281307P
60281317P
60281327P
60281337P
2 500
60391014P
60391004P
60391034P
60391024P
60391304P
60391314P
60391324P
60391334P
3 200
60391016P
60391006P
60391036P
60391026P
60391306P
60391316P
60391326P
60391336P
4 000
60391017P
60391007P
60391037P
60391027P
60391307P
60391317P
60391327P
60391337P
Key : How to select the correct configuration of bar The 4th digit of an SCP Cat. No. determines the busbar configuration All examples on this page show 4 conductor versions, ie. 8 or 9; 5 conductor and 200% neutral versions are available by substituting the 4th digit with 4, 5, 6 or 7, as shown opposite
Single bar Double bar
3L + N + PE 8 9
3L + N + FE+ PE 3L + 2N + PE 4 5 6 7
TRUNKING LENGTHS Expansion lengths
Distribution lengths 3 m – 3 + 3 outlets
2 m – 2 + 2 outlets
1 m – 1 + 1 outlets
60280130P
60280260P
60280280P
60280131P
60280261P
60280132P
Fire barriers
Transposition lengths Phase transposition
Neutral rotation
Internal
External
60280290P
60287100P
60287140P
653IFB01
652EFB01
60280281P
60280291P
60287101P
60287141P
–
652EFB01
60280262P
60280282P
60280292P
60287102P
60287142P
–
652EFB01
60280134P
60280264P
60280284P
60280294P
60287104P
60287144P
–
652EFB01
60280136P
60280266P
60280286P
60280296P
60287106P
60287146P
–
652EFB02
60280137P
60280267P
60280287P
60280297P
60287107P
60287147P
–
652EFB04
60390134P
60390264P
60390284P
60390294P
60397104P
60397144P
653IFB01
653EFB02
60390136P
60390266P
60390286P
60390296P
60397106P
60397146P
653IFB01
653EFB03
60390137P
60390267P
60390287P
60390297P
60397107P
60397147P
653IFB01
653EFB04
ELBOWS AND TEES Double vertical elbows
Vertical tees
Bespoke dimensions
Bespoke dimensions
Left + right hand
Right + left hand Right hand female Right hand male 300 to 1 499 mm 300 to 1 499 mm
Horizontal tees
Left hand male 300 to 1 499 mm
Bespoke dimensions Left hand female Right hand female Right hand male 300 to 1 499 mm 550 to 1 049 mm 550 to 1 049 mm
Left hand male 550 to 1 049 mm
Left hand female 550 to 1 049 mm
60280450P
60280440P
60280800P
60280810P
60280820P
60280830P
60280700P
60280710P
60280720P
60280730P
60280451P
60280441P
60280801P
60280811P
60280821P
60280831P
60280701P
60280711P
60280721P
60280731P
60280452P
60280442P
60280802P
60280812P
60280822P
60280832P
60280702P
60280712P
60280722P
60280732P
60280454P
60280444P
60280804P
60280814P
60280824P
60280834P
60280704P
60280714P
60280724P
60280734P
60280456P
60280446P
60280806P
60280816P
60280826P
60280836P
60280706P
60280716P
60280726P
60280736P
60280457P
60280447P
60280807P
60280817P
60280827P
60280837P
60280707P
60280717P
60280727P
60280737P
60390454P
60390444P
60390804P
60390814P
60390824P
60390834P
60390704P
60390714P
60390724P
60390734P
60390456P
60390446P
60390806P
60390816P
60390826P
60390836P
60390706P
60390716P
60390726P
60390736P
60390457P
60390447P
60390807P
60390817P
60390827P
60390837P
60390707P
60390717P
60390727P
60390737P
CONNECTION INTERFACES
FEED UNITS AND END STOPS
Connection interfaces + vertical elbows
End feed units
End stops
Bespoke dimensions Type 1 female
Type 2 female
Type 3 male
Type 4 male
Type 1 male
Type 2 female
60281400P
60281410P
60281420P
60281430P
60281110P
60281100P
65283101P
60281401P
60281411P
60281421P
60281431P
60281111P
60281101P
65283101P
60281402P
60281412P
60281422P
60281432P
60281112P
60281102P
65283101P
60281404P
60281414P
60281424P
60281434P
60281114P
60281104P
65283101P
60281406P
60281416P
60281426P
60281436P
60281116P
60281106P
65283102P
60281407P
60281417P
60281427P
60281437P
60281117P
60281107P
65283104P
60391404P
60391414P
60391424P
60391434P
60391114P
60391104P
65393102P
60391406P
60391416P
60391426P
60391436P
60391116P
60391106P
65393103P
60391407P
60391417P
60391427P
60391437P
60391117P
60391107P
65393104P
63
SCP super compact busbar copper conductors
TRUNKING LENGTHS Feeder lengths
Rating (A) Standard 3 m
Bespoke dimensions 1 to 1路5 m Bespoke dimensions 1路5 to 2 m Bespoke dimensions 2 to 2路5 m Bespoke dimensions 2路5 to 3 m
800
65280100P
65280170P
65280120P
65280180P
65280150P
1 000
65280101P
65280171P
65280121P
65280181P
65280151P
1 250
65280103P
65280173P
65280123P
65280183P
65280153P
1 600
65280105P
65280175P
65280125P
65280185P
65280155P
2 000
65280106P
65280176P
65280126P
65280186P
65280156P
2 500
65280108P
65280178P
65280128P
65280188P
65280158P
3 200
65390105P
65390175P
65390125P
65390185P
65390155P
4 000
65390106P
65390176P
65390126P
65390186P
65390156P
5 000
65390108P
65390178P
65390128P
65390188P
65390158P
ELBOWS AND TEES Horizontal elbows Rating (A)
Double horizontal elbows
Vertical elbows
Standard dimensions
Bespoke dimensions
Standard dimensions
Bespoke dimensions
Right hand
Right hand
Right hand
Right hand
Left hand
Left hand
Left hand
Bespoke dimensions Left + right hand Right + left hand
Left hand
800
65280300P 65280310P
65280320P
65280330P 65280400P 65280410P
65280420P 65280430P
65280350P
65280340P
1 000
65280301P 65280311P
65280321P
65280331P 65280401P 65280411P
65280421P 65280431P
65280351P
65280341P
1 250
65280303P 65280313P
65280323P
65280333P 65280403P 65280413P
65280423P 65280433P
65280353P
65280343P
1 600
65280305P 65280315P
65280325P
65280335P 65280405P 65280415P
65280425P 65280435P
65280355P
65280345P
2 000
65280306P 65280316P
65280326P
65280336P 65280406P 65280416P
65280426P 65280436P
65280356P
65280346P
2 500
65280308P 65280318P
65280328P
65280338P 65280408P 65280418P
65280428P 65280438P
65280358P
65280348P
3 200
65390305P 65390315P
65390325P
65390335P 65390405P 65390415P
65390425P 65390435P
65390355P
65390345P
4 000
65390306P 65390316P
65390326P
65390336P 65390406P 65390416P
65390426P 65390436P
65390356P
65390346P
5 000
65390308P 65390318P
65390328P
65390338P 65390408P 65390418P
65390428P 65390438P
65390358P
65390348P
CONNECTION INTERFACES Connection interfaces Rating (A)
64
Standard dimensions
Connection interfaces + horizontal elbows
Bespoke dimensions
Bespoke dimensions
Type 1 male
Type 2 female
Type 1 male
Type 2 female
Type 1 female
Type 2 female
Type 3 male
Type 4 male
800
65281010P
65281000P
65281030P
65281020P
65281300P
65281310P
65281320P
65281330P
1 000
65281011P
65281001P
65281031P
65281021P
65281301P
65281311P
65281321P
65281331P
1 250
65281013P
65281003P
65281033P
65281023P
65281303P
65281313P
65281323P
65281333P
1 600
65281015P
65281005P
65281035P
65281025P
65281305P
65281315P
65281325P
65281335P
2 000
65281016P
65281006P
65281036P
65281026P
65281306P
65281316P
65281326P
65281336P
2 500
65281018P
65281008P
65281038P
65281028P
65281308P
65281318P
65281328P
65281338P
3 200
65391015P
65391005P
65391035P
65391025P
65391305P
65391315P
65391325P
65391335P
4 000
65391016P
65391006P
65391036P
65391026P
65391306P
65391316P
65391326P
65391336P
5 000
65391018P
65391008P
65391038P
65391028P
65391308P
65391318P
65391328P
65391338P
Key : How to select the correct configuration of bar The 4th digit of an SCP Cat. No. determines the busbar configuration All examples on this page show 4 conductor versions, ie. 8 or 9; 5 conductor and 200% neutral versions are available by substituting the 4th digit with 4, 5, 6 or 7, as shown opposite
Single bar Double bar
3L + N + PE 8 9
3L + N + FE+ PE 3L + 2N + PE 4 5 6 7
TRUNKING LENGTHS Expansion lengths
Distribution lengths 3 m – 3 + 3 outlets
2 m – 2 + 2 outlets
1 m – 1 + 1 outlets
65280130P
65280260P
65280280P
65280131P
65280261P
65280133P
Fire barriers
Transposition lengths Phase transposition
Neutral rotation
Internal
External
65280290P
65287100P
65287140P
653IFB01
652EFB51
65280281P
65280291P
65287101P
65287141P
–
652EFB51
65280263P
65280283P
65280293P
65287103P
65287143P
–
652EFB51
65280135P
65280265P
65280285P
65280295P
65287105P
65287145P
–
652EFB52
65280136P
65280266P
65280286P
65280296P
65287106P
65287146P
–
652EFB52
65280138P
65280268P
65280288P
65280298P
65287108P
65287148P
–
652EFB54
65390135P
65390265P
65390285P
65390295P
65397105P
65397145P
653IFB01
653EFB52
65390136P
65390266P
65390286P
65390296P
65397106P
65397146P
653IFB01
653EFB53
65390138P
65390268P
65390288P
65390298P
65397108P
65397148P
653IFB01
653EFB54
ELBOWS AND TEES Double vertical elbows
Vertical tees
Bespoke dimensions
Bespoke dimensions
Left + right hand
Right + left hand Right hand female Right hand male 300 to 1 499 mm 300 to 1 499 mm
Horizontal tees
Left hand male 300 to 1 499 mm
Bespoke dimensions Left hand female Right hand female Right hand male 300 to 1 499 mm 550 to 1 049 mm 550 to 1 049 mm
Left hand male 550 to 1 049 mm
Left hand female 550 to 1 049 mm
65280450P
65280440P
65280800P
65280810P
65280820P
65280830P
65280700P
65280710P
65280720P
65280730P
65280451P
65280441P
65280801P
65280811P
65280821P
65280831P
65280701P
65280711P
65280721P
65280731P
65280453P
65280443P
65280803P
65280813P
65280823P
65280833P
65280703P
65280713P
65280723P
65280733P
65280455P
65280445P
65280805P
65280815P
65280825P
65280835P
65280705P
65280715P
65280725P
65280735P
65280456P
65280446P
65280806P
65280816P
65280826P
65280836P
65280706P
65280716P
65280726P
65280736P
65280458P
65280448P
65280808P
65280818P
65280828P
65280838P
65280708P
65280718P
65280728P
65280738P
65390455P
65390445P
65390805P
65390815P
65390825P
65390835P
65390705P
65390715P
65390725P
65390735P
65390456P
65390446P
65390806P
65390816P
65390826P
65390836P
65390706P
65390716P
65390726P
65390736P
65390458P
65390448P
65390808P
65390818P
65390828P
65390838P
65390708P
65390718P
65390728P
65390738P
CONNECTION INTERFACES
FEED UNITS AND END STOPS
Connection interfaces + vertical elbows
End feed units
End stops
Bespoke dimensions Type 1 female
Type 2 female
Type 3 male
Type 4 male
Type 1 male
Type 2 female
65281400P
65281410P
65281420P
65281430P
65281110P
65281100P
65283101P
65281401P
65281411P
65281421P
65281431P
65281111P
65281101P
65283101P
65281403P
65281413P
65281423P
65281433P
65281113P
65281103P
65283101P
65281405P
65281415P
65281425P
65281435P
65281115P
65281105P
65283102P
65281406P
65281416P
65281426P
65281436P
65281116P
65281106P
65283102P
65281408P
65281418P
65281428P
65281438P
65281118P
65281108P
65283104P
65391405P
65391415P
65391425P
65391435P
65391115P
65391105P
65393102P
65391406P
65391416P
65391426P
65391436P
65391116P
65391106P
65393103P
65391408P
65391418P
65391428P
65391438P
65391118P
65391108P
65393104P
65
SCP super compact busbar feeder lengths
The SCP system is also available in 5 conductor versions and up to 6 300 A (copper) Contact us on +44 (0) 370 608 9020
Single bar feeder length Selection charts p. 62-65 Dimensions and technical information p. 95 Technical data p. 112-117
High power busbar from 630 A to 4 000 A with aluminium alloy conductors and from 800 A to 5 000 A with copper conductors SCP complies with IEC 61439-6 (BS EN 61439-6) Supplied with electrical junction monobloc system pre-installed Pack
Feeder lengths – standard 3 m
Cat. Nos.
Pack
Feeder lengths – bespoke dimensions
Cat. Nos.
(continued)
For runs exceeding 40 m an expansion length should be included (see p. 68)
Please specify required length when ordering 1 501 - 2 000 mm double bar
3 000 mm single bar Aluminium
1 1 1 1 1 1 1
60280100P 60280101P 60280102P 60280104P 60280106P 60280107P
Copper
65280100P 65280101P 65280103P 65280105P 65280106P 65280108P
Rating (A)
630 800 1 000 1 250 1 600 2 000 2 500 3 000 mm double bar Rating (A)
1 1 1 1
60390104P 60390106P 60390107P
65390105P 65390106P 65390108P
2 500 3 200 4 000 5 000
Feeder lengths – bespoke dimensions Please specify required length when ordering 1 000 - 1 500 mm single bar Aluminium
1 1 1 1 1 1 1
60280170P 60280171P 60280172P 60280174P 60280176P 60280177P
1 1 1 1
60390174P 60390176P 60390177P
Copper
65280170P 65280171P 65280173P 65280175P 65280176P 65280178P
Aluminium
1 1 1 1
60390124P 60390126P 60390127P
1 1 1 1 1 1 1
60280180P 60280181P 60280182P 60280184P 60280186P 60280187P
1 1 1 1
60390184P 60390186P 60390187P
Copper
65390125P 65390126P 65390128P
65280180P 65280181P 65280183P 65280185P 65280186P 65280188P
2 500 3 200 4 000 5 000
630 800 1 000 1 250 1 600 2 000 2 500 2 001 - 2 500 mm double bar Rating (A)
65390185P 65390186P 65390188P
2 500 3 200 4 000 5 000 2 501 - 2 999 mm single bar Rating (A)
1 1 1 1 1 1 1
60280150P 60280151P 60280152P 60280154P 60280156P 60280157P
1 1 1 1
60390154P 60390156P 60390157P
65280150P 65280151P 65280153P 65280155P 65280156P 65280158P
Rating (A)
65390175P 65390176P 65390178P
2 500 3 200 4 000 5 000 2 001 - 2 500 mm single bar Rating (A)
Rating (A)
630 800 1 000 1 250 1 600 2 000 2 500 1 000 - 1 500 mm double bar
Rating (A)
630 800 1 000 1 250 1 600 2 000 2 500 2 501 - 2 999 mm double bar Rating (A)
65390155P 65390156P 65390158P
2 500 3 200 4 000 5 000
1 501 - 2 000 mm single bar Rating (A)
1 1 1 1 1 1 1
60280120P 60280121P 60280122P 60280124P 60280126P 60280127P
65280120P 65280121P 65280123P 65280125P 65280126P 65280128P
630 800 1 000 1 250 1 600 2 000 2 500
Key : How to select the correct configuration of bar The 4th digit of an SCP Cat. No. determines the busbar configuration All examples on this page show 4 conductor versions, ie. 8 or 9; 5 conductor and 200% neutral versions are available by substituting the 4th digit with 4, 5, 6 or 7, as shown below
Single bar Double bar
66
3L + N + PE 8 9
3L + N + FE+ PE 3L + 2N + PE 4 5 6 7
SCP super compact busbar distribution lengths
Single bar distribution length Selection charts p. 62-65 Dimensions and technical information p. 95 Technical data p. 112-117 High power busbar from 630 A to 4 000 A with aluminium alloy conductors and from 800 A to 5 000 A with copper conductors SCP complies with IEC 61439-6 (BS EN 61439-6) Supplied with electrical junction monobloc system pre-installed Pack
Distribution lengths
Cat. Nos.
Pack
Distribution lengths
Cat. Nos.
(continued) 2 001 - 2 500 mm double bar – 2 + 2 outlets2
For plug-in type tap-off boxes For runs exceeding 40 m an expansion length should be included Tap-off outlets are spaced at 850 mm intervals on both sides and are provided with hinged covers to ensure maximum safety and maintain IP 55 protection 3 000 m single bar – 3 + 3 outlets2 Aluminium
1 1 1 1 1 1 1
60280130P1 60280131P 60280132P 60280134P 60280136P 60280137P
1 1 1 1
60390134P 60390136P 60390137P
Copper
Rating (A)
65280130P1 65280131P 65280133P 65280135P 65280136P 65280138P
630 800 1 000 1 250 1 600 2 000 2 500 3 000 m double bar – 3 + 3 outlets2
Aluminium
1 1 1 1
60390984P 60390986P 60390987P
Copper
Rating (A)
65390985P 65390986P 65390988P
1 501 - 2 000 mm single bar – 2 + 2 outlets2 Rating (A)
1 1 1 1 1 1 1
60280920P1 60280921P 60280922P 60280924P 60280926P 60280927P
1 1 1 1
60390924P 60390926P 60390927P
1 1 1 1 1 1 1
60280970P1 60280971P 60280972P 60280974P 60280976P 60280977P
1 1 1 1
60390974P 60390976P 60390977P
65280920P 65280921P 65280923P 65280925P 65280926P 65280928P
1
Rating (A)
65390135P 65390136P 65390138P
2 500 3 200 4 000 5 000
65390925P 65390926P 65390928P
Rating (A)
60280950P1 60280951P 60280952P 60280954P 60280956P 60280957P
1 1 1 1
60390954P 60390956P 60390957P
65280950P 65280951P 65280953P 65280955P 65280956P 65280958P
1
630 800 1 000 1 250 1 600 2 000 2 500 2 501 - 2 999 mm double bar – 3 + 3 outlets2
65390955P 65390956P 65390958P
2 001 - 2 500 mm single bar – 2 + 2 outlets2
2 500 3 200 4 000 5 000 1 001 - 1 500 mm single bar – 1 + 1 outlets Rating (A)
65280970P 65280971P 65280973P 65280975P 65280976P 65280978P
1
Rating (A)
2 500 3 200 4 000 5 000
630 800 1 000 1 250 1 600 2 000 2 500 1 501 - 2 000 mm double bar – 2 + 2 outlets2 Rating (A)
2 501 - 2 999 mm single bar – 3 + 3 outlets2 1 1 1 1 1 1 1
2 500 3 200 4 000 5 000
630 800 1 000 1 250 1 600 2 000 2 500 1 001 - 1 500 mm double bar – 1 + 1 outlets Rating (A)
65390975P 65390976P 65390978P
2 500 3 200 4 000 5 000
For feed units and tap-off boxes p. 77, 78-79
Rating (A)
1 1 1 1 1 1 1
60280980P1 60280981P 60280982P 60280984P 60280986P 60280987P
65280980P1 65280981P 65280983P 65280985P 65280986P 65280988P
630 800 1 000 1 250 1 600 2 000 2 500
1 : Lengths with tap-off outlets on top side only (3, 2 or 1 + 0) 2 : For other combination of outlets please contact us +44 (0) 370 608 9020
Key : How to select the correct configuration of bar The 4th digit of an SCP Cat. No. determines the busbar configuration All examples on this page show 4 conductor versions, ie. 8 or 9; 5 conductor and 200% neutral versions are available by substituting the 4th digit with 4, 5, 6 or 7, as shown below
Single bar Double bar
3L + N + PE 8 9
3L + N + FE+ PE 3L + 2N + PE 4 5 6 7
67
SCP super compact busbar expansion and transposition lengths
1
N
1
2
2
3
N N
N 3
Single bar phase transposition length
1
2
3
1
2
3
Single bar neutral rotation length
Single bar expansion length Selection charts p. 62-65 Dimensions and technical information p. 95 Technical data p. 112-117
High power busbar from 630 A to 4 000 A with aluminium alloy conductors and from 800 A to 5 000 A with copper conductors SCP complies with IEC 61439-6 (BS EN 61439-6) Supplied with electrical junction monobloc system pre-installed Pack
Expansion lengths
Cat. Nos.
Pack
Standard – 3 m Absorb the thermal expansion during normal use that, on long runs, would otherwise cumulate and put abnormal force on the connection points Expansion length is to be placed in straight runs of more than 40 m and repeated every 40 m Single bar Aluminium
1 1 1 1 1 1 1
60280290P 60280291P 60280292P 60280294P 60280296P 60280297P
Copper
Rating (A)
65280290P 65280291P 65280293P 65280295P 65280296P 65280298P
630 800 1 000 1 250 1 600 2 000 2 500 Double bar Rating (A)
1 1 1 1
60390294P 60390296P 60390297P
65390295P 65390296P 65390298P
2 500 3 200 4 000 5 000
Transposition lengths
Cat. Nos.
Phase transposition – 1·2 m In runs exceeding 100 m it is recommended to include two transposition lengths to balance mutual phase reactance and electric impedance (one at 1/3 and one at 2/3 distance of the run) Single bar Aluminium
1 1 1 1 1 1 1
60287100P 60287101P 60287102P 60287104P 60287106P 60287107P
1 1 1 1
60397104P 60397106P 60397107P
Copper
Rating (A)
65287100P 65287101P 65287103P 65287105P 65287106P 65287108P
630 800 1 000 1 250 1 600 2 000 2 500 Double bar Rating (A)
65397105P 65397106P 65397108P
2 500 3 200 4 000 5 000 Neutral rotation – 1·0 m When the sequence of the distribution board phases is different to that of the transformer Single bar Rating (A)
1 1 1 1 1 1 1
60287140P 60287141P 60287142P 60287144P 60287146P 60287147P
1 1 1 1
60397144P 60397146P 60397147P
65287140P 65287141P 65287143P 65287145P 65287146P 65287148P
630 800 1 000 1 250 1 600 2 000 2 500 Double bar Rating (A)
Key : How to select the correct configuration of bar The 4th digit of an SCP Cat. No. determines the busbar configuration All examples on this page show 4 conductor versions, ie. 8 or 9; 5 conductor and 200% neutral versions are available by substituting the 4th digit with 4, 5, 6 or 7, as shown below
Single bar Double bar
68
3L + N + PE 8 9
3L + N + FE+ PE 3L + 2N + PE 4 5 6 7
65397145P 65397146P 65397148P
2 500 3 200 4 000 5 000
SCP super compact busbar fire barriers and end stops
Single bar external fire barrier
End stop
Selection charts p. 62-65 Dimensions and technical information p. 96 Technical data p. 112-117 High power busbar from 630 A to 4 000 A with aluminium alloy conductors and from 800 A to 5 000 A with copper conductors SCP complies with IEC 61439-6 (BS EN 61439-6) Supplied with electrical junction monobloc system pre-installed Pack
1
Internal fire barrier
Cat. Nos.
653IFB01
Meets class S120 (EN 1366-3, DIN 4102-09) Internal fire barriers are not required for 800 to 2 000 A aluminium systems, or 1 000 to 2 500 A copper systems but can be supplied with all other trunking components Internal fire barrier
External fire barriers Meets class S120 (EN 1366-3, DIN 4102-09) External fire barriers can be used on any trunking component in compliance with the operating instructions (see p. 96) Please specify the required position of the fire barrier when ordering (see p. 96)
Pack
End stops
Cat. Nos.
Maintain IP 55 protection at the end of the run Single bar Aluminium
1 1 1 1 1 1
Copper
65283101P 65283101P 65283102P 65283102P 65283104P 65283104P
Rating (A)
630 to 1 250 800 to 1 250 1 600 1 600 to 2 000 2 000 2 500 Double bar Rating (A)
1 1 1 1 1 1
65393102P 65393102P 65393103P 65393103P 65393104P 65393104P
2 500 3 200 3 200 4 000 4 000 5 000
External single bar Aluminium
1 1 1 1 1 1
Copper
Rating (A)
652EFB51 652EFB52 652EFB54
630, 800, 1 000, 1 250 1 600 2 000 800, 1 000, 1 250 1 600, 2 000 2 500
652EFB01 652EFB02 652EFB04
External double bar Rating (A)
1 1 1 1 1 1
653EFB02 653EFB03 653EFB04 653EFB52 653EFB53 653EFB54
2 500 3 200 4 000 3 200 4 000 5 000
Key : How to select the correct configuration of bar The 4th digit of an SCP Cat. No. determines the busbar configuration All examples on this page show 4 conductor versions, ie. 8 or 9; 5 conductor and 200% neutral versions are available by substituting the 4th digit with 4, 5, 6 or 7, as shown below
Single bar Double bar
3L + N + PE 8 9
3L + N + FE+ PE 3L + 2N + PE 4 5 6 7
69
SCP super compact busbar horizontal elbows
Single bar horizontal elbow
Selection charts p. 62-65 Dimensions and technical information p. 96 Technical data p. 112-117 High power busbar from 630 A to 4 000 A with aluminium alloy conductors and from 800 A to 5 000 A with copper conductors SCP complies with IEC 61439-6 (BS EN 61439-6) Elbows are supplied with pre-installed monobloc and are able to change direction with standard or bespoke dimensions Pack
Horizontal elbows – standard 300 x 300 mm
Cat. Nos.
Pack
Horizontal elbows – bespoke dimensions
Cat. Nos.
Right hand – single bar Aluminium
1 1 1 1 1 1 1
60280300P 60280301P 60280302P 60280304P 60280306P 60280307P
1 1 1 1
60390304P 60390306P 60390307P
Copper
65280300P 65280301P 65280303P 65280305P 65280306P 65280308P
630 800 1 000 1 250 1 600 2 000 2 500 Right hand – double bar Rating (A)
65390305P 65390306P 65390308P
Please specify required length when ordering (see p. 96 for configuration)
Rating (A)
2 500 3 200 4 000 5 000
Right hand – single bar 250 to 1 299 mm Aluminium
1 1 1 1 1 1 1
60280320P 60280321P 60280322P 60280324P 60280326P 60280327P
1 1 1 1
60390324P 60390326P 60390327P
Copper
65280320P 65280321P 65280323P 65280325P 65280326P 65280328P
Left hand – single bar Rating (A)
1 1 1 1 1 1 1
60280310P 60280311P 60280312P 60280314P 60280316P 60280317P
65280310P 65280311P 65280313P 65280315P 65280316P 65280318P
630 800 1 000 1 250 1 600 2 000 2 500 Left hand – double bar Rating (A)
1 1 1 1
60390314P 60390316P 60390317P
65390315P 65390316P 65390318P
2 500 3 200 4 000 5 000
Rating (A)
630 800 1 000 1 250 1 600 2 000 2 500 Right hand – double bar 250 to 1 449 mm Rating (A)
65390325P 65390326P 65390328P
2 500 3 200 4 000 5 000 Left hand – single bar 250 to 1 299 mm Rating (A)
1 1 1 1 1 1 1
60280330P 60280331P 60280332P 60280334P 60280336P 60280337P
1 1 1 1
60390334P 60390336P 60390337P
65280330P 65280331P 65280333P 65280335P 65280336P 65280338P
630 800 1 000 1 250 1 600 2 000 2 500 Left hand – double bar 250 to 1 449 mm Rating (A)
65390335P 65390336P 65390338P
2 500 3 200 4 000 5 000
Key : How to select the correct configuration of bar The 4th digit of an SCP Cat. No. determines the busbar configuration All examples on this page show 4 conductor versions, ie. 8 or 9; 5 conductor and 200% neutral versions are available by substituting the 4th digit with 4, 5, 6 or 7, as shown below
Single bar Double bar
70
3L + N + PE 8 9
3L + N + FE+ PE 3L + 2N + PE 4 5 6 7
SCP super compact busbar vertical elbows
Single bar – vertical elbow
Selection charts p. 62-65 Dimensions and technical information p. 96 Technical data p. 112-117 High power busbar from 630 A to 4 000 A with aluminium alloy conductors and from 800 A to 5 000 A with copper conductors SCP complies with IEC 61439-6 (BS EN 61439-6) Elbows are supplied with pre-installed monobloc and are able to change direction with standard or bespoke dimensions Pack
Vertical elbows – standard
Cat. Nos.
Pack
Vertical elbows – bespoke dimensions
Cat. Nos.
Left hand – single bar 300 x 300 mm Aluminium
1 1 1 1 1 1 1
60280410P 60280411P 60280412P 60280414P 60280416P 60280417P
1 1 1 1
60390414P 60390416P 60390417P
Copper
65280410P 65280411P 65280413P 65280415P 65280416P 65280418P
630 800 1 000 1 250 1 600 2 000 2 500 Left hand – double bar 450 x 450 mm Rating (A)
65390415P 65390416P 65390418P
2 500 3 200 4 000 5 000 Right hand – single bar 300 x 300 mm Rating (A)
1 1 1 1 1 1 1
60280400P 60280401P 60280402P 60280404P 60280406P 60280407P
1 1 1 1
60390404P 60390406P 60390407P
65280400P 65280401P 65280403P 65280405P 65280406P 65280408P
630 800 1 000 1 250 1 600 2 000 2 500 Right hand – double bar 450 x 450 mm Rating (A)
65390405P 65390406P 65390408P
Please specify required length when ordering (see p. 96 for configuration)
Rating (A)
2 500 3 200 4 000 5 000
Left hand – single bar 300 to 1 299 mm Aluminium
1 1 1 1 1 1 1
60280430P 60280431P 60280432P 60280434P 60280436P 60280437P
1 1 1 1
60390434P 60390436P 60390437P
Copper
65280430P 65280431P 65280433P 65280435P 65280436P 65280438P
Rating (A)
630 800 1 000 1 250 1 600 2 000 2 500 Left hand – double bar 450 to 1 449 mm Rating (A)
65390435P 65390436P 65390438P
2 500 3 200 4 000 5 000 Right hand – single bar 300 to 1 299 mm Rating (A)
1 1 1 1 1 1 1
60280420P 60280421P 60280422P 60280424P 60280426P 60280427P
1 1 1 1
60390424P 60390426P 60390427P
65280420P 65280421P 65280423P 65280425P 65280426P 65280428P
630 800 1 000 1 250 1 600 2 000 2 500 Right hand – double bar 450 to 1 449 mm Rating (A)
65390425P 65390426P 65390428P
2 500 3 200 4 000 5 000
Key : How to select the correct configuration of bar The 4th digit of an SCP Cat. No. determines the busbar configuration All examples on this page show 4 conductor versions, ie. 8 or 9; 5 conductor and 200% neutral versions are available by substituting the 4th digit with 4, 5, 6 or 7, as shown below
Single bar Double bar
3L + N + PE 8 9
3L + N + FE+ PE 3L + 2N + PE 4 5 6 7
71
SCP super compact busbar double elbows
Single bar – double horizontal elbow Single bar – double vertical elbow Selection charts p. 62-65 Dimensions and technical information p. 96-97 Technical data p. 112-117 High power busbar from 630 A to 4 000 A with aluminium alloy conductors and from 800 A to 5 000 A with copper conductors SCP complies with IEC 61439-6 (BS EN 61439-6) Elbows are supplied with pre-installed monobloc and are able to change direction with standard or bespoke dimensions Pack
Double horizontal elbows – bespoke dimensions1
Cat. Nos.
Pack
Double vertical elbows – bespoke dimensions2
Cat. Nos.
Please specify required length when ordering (see p. 96 for configuration)
Please specify required length when ordering (see p. 97 for configuration)
Left + right hand – single bar Aluminium
1 1 1 1 1 1 1
60280350P 60280351P 60280352P 60280354P 60280356P 60280357P
Copper
65280350P 65280351P 65280353P 65280355P 65280356P 65280358P
Left + right hand – single bar
Rating (A)
630 800 1 000 1 250 1 600 2 000 2 500
Aluminium
1 1 1 1 1 1 1
60280450P 60280451P 60280452P 60280454P 60280456P 60280457P
Copper
65280450P 65280451P 65280453P 65280455P 65280456P 65280458P
Left + right hand – double bar 60390354P 60390356P 60390357P
65390355P 65390356P 65390358P
2 500 3 200 4 000 5 000
630 800 1 000 1 250 1 600 2 000 2 500 Left + right hand – double bar
Rating (A)
1 1 1 1
Rating (A)
Rating (A)
1 1 1 1
60390454P 60390456P 60390457P
65390455P 65390456P 65390458P
2 500 3 200 4 000 5 000
Right + left hand – single bar Right + left hand – single bar
Rating (A)
1 1 1 1 1 1 1
60280340P 60280341P 60280342P 60280344P 60280346P 60280347P
65280340P 65280341P 65280343P 65280345P 65280346P 65280348P
630 800 1 000 1 250 1 600 2 000 2 500 Right + left hand – double bar
Rating (A)
1 1 1 1 1 1 1
60280440P 60280441P 60280442P 60280444P 60280446P 60280447P
65280440P 65280441P 65280443P 65280445P 65280446P 65280448P
Right + left hand – double bar
Rating (A)
1 1 1 1
60390344P 60390346P 60390347P
65390345P 65390346P 65390348P
2 500 3 200 4 000 5 000
630 800 1 000 1 250 1 600 2 000 2 500 Rating (A)
1 1 1 1
60390444P 60390446P 60390447P
65390445P 65390446P 65390448P
2 500 3 200 4 000 5 000
2 : Standard dimensions 300 + 300 + 300 mm single bar and 450 + 450 + 450 mm double bar
Key : How to select the correct configuration of bar The 4th digit of an SCP Cat. No. determines the busbar configuration All examples on this page show 4 conductor versions, ie. 8 or 9; 5 conductor and 200% neutral versions are available by substituting the 4th digit with 4, 5, 6 or 7, as shown below
1 : Standard dimensions 300 + 300 + 300 mm
72
Single bar Double bar
3L + N + PE 8 9
3L + N + FE+ PE 3L + 2N + PE 4 5 6 7
SCP super compact busbar vertical tees
Single bar vertical tee Selection charts p. 62-65 Dimensions and technical information p. 97 Technical data p. 112-117 High power busbar from 630 A to 4 000 A with aluminium alloy conductors and from 800 A to 5 000 A with copper conductors SCP complies with IEC 61439-6 (BS EN 61439-6) Tees are supplied with pre-installed monobloc and are able to change direction with standard or bespoke dimensions Pack
Aluminium
1 1 1 1 1 1 1
Vertical tees – bespoke dimensions1
Cat. Nos.
60280800P 60280801P 60280802P 60280804P 60280806P 60280807P
Copper
65280800P 65280801P 65280803P 65280805P 65280806P 65280808P
Pack
Vertical tees – bespoke dimensions (continued)1
Cat. Nos.
Please specify required length when ordering (see p. 97 for configuration)
Please specify required length when ordering (see p. 97 for configuration)
Right hand female – single bar 300 to 1 299 mm
Left hand male – single bar 300 to 1 299 mm
Rating (A)
630 800 1 000 1 250 1 600 2 000 2 500
Aluminium
1 1 1 1 1 1 1
60280820P 60280821P 60280822P 60280824P 60280826P 60280827P
Copper
65280820P 65280821P 65280823P 65280825P 65280826P 65280828P
Right hand female – double bar 450 to 1 449 mm 60390804P 60390806P 60390807P
65390805P 65390806P 65390808P
2 500 3 200 4 000 5 000
Rating (A)
1 1 1 1
60390824P 60390826P 60390827P
65390825P 65390826P 65390828P
Right hand male – single bar 300 to 1 299 mm 60280810P 60280811P 60280812P 60280814P 60280816P 60280817P
65280810P 65280811P 65280813P 65280815P 65280816P 65280818P
630 800 1 000 1 250 1 600 2 000 2 500
Rating (A)
1 1 1 1 1 1 1
60280830P 60280831P 60280832P 60280834P 60280836P 60280837P
65280830P 65280831P 65280833P 65280835P 65280836P 65280838P
Right hand male – double bar 450 to 1 449 mm 60390814P 60390816P 60390817P
65390815P 65390816P 65390818P
2 500 3 200 4 000 5 000
630 800 1 000 1 250 1 600 2 000 2 500 Left hand female – double bar 450 to 1 449 mm
Rating (A)
1 1 1 1
2 500 3 200 4 000 5 000 Left hand female – single bar 300 to 1 299 mm
Rating (A)
1 1 1 1 1 1 1
630 800 1 000 1 250 1 600 2 000 2 500 Left hand male – double bar 450 to 1 449 mm
Rating (A)
1 1 1 1
Rating (A)
Rating (A)
1 1 1 1
60390834P 60390836P 60390837P
65390835P 65390836P 65390838P
2 500 3 200 4 000 5 000
Key : How to select the correct configuration of bar The 4th digit of an SCP Cat. No. determines the busbar configuration All examples on this page show 4 conductor versions, ie. 8 or 9; 5 conductor and 200% neutral versions are available by substituting the 4th digit with 4, 5, 6 or 7, as shown below
1 : Standard dimensions 300 + 300 + 300 mm single bar and 600 + 600 + 600 mm double bar
Single bar Double bar
3L + N + PE 8 9
3L + N + FE+ PE 3L + 2N + PE 4 5 6 7
73
SCP super compact busbar horizontal tees
Single bar horizontal tee
Selection charts p. 62-65 Dimensions and technical information p. 98 Technical data p. 112-117 High power busbar from 630 A to 4 000 A with aluminium alloy conductors and from 800 A to 5 000 A with copper conductors SCP complies with IEC 61439-6 (BS EN 61439-6) Tees are supplied with pre-installed monobloc and are able to change direction with standard or bespoke dimensions Pack
Cat. Nos
Aluminium
1 1 1 1 1 1 1
60280700P 60280701P 60280702P 60280704P 60280706P 60280707P
.
Copper
65280700P 65280701P 65280703P 65280705P 65280706P 65280708P
Horizontal tees – bespoke dimensions1
Pack
Horizontal tees – bespoke dimensions (continued)1
Cat. Nos.
Please specify required length when ordering (see p. 98 for configuration)
Please specify required length when ordering (see p. 98 for configuration)
Right hand female – single bar 550 to 1 049 mm
Left hand male – single bar 550 to 1 049 mm
Rating (A)
630 800 1 000 1 250 1 600 2 000 2 500
Aluminium
1 1 1 1 1 1 1
60280720P 60280721P 60280722P 60280724P 60280726P 60280727P
Copper
65280720P 65280721P 65280723P 65280725P 65280726P 65280728P
Right hand female – double bar 550 to 1 049 mm 60390704P 60390706P 60390707P
65390705P 65390706P 65390708P
2 500 3 200 4 000 5 000
Rating (A)
1 1 1 1
60390724P 60390726P 60390727P
65390725P 65390726P 65390728P
Right hand male – single bar 550 to 1 049 mm 60280710P 60280711P 60280712P 60280714P 60280716P 60280717P
65280710P 65280711P 65280713P 65280715P 65280716P 65280718P
630 800 1 000 1 250 1 600 2 000 2 500
Rating (A)
1 1 1 1 1 1 1
60280730P 60280731P 60280732P 60280734P 60280736P 60280737P
65280730P 65280731P 65280733P 65280735P 65280736P 65280738P
Right hand male – double bar 550 to 1 049 mm 60390714P 60390716P 60390717P
65390715P 65390716P 65390718P
2 500 3 200 4 000 5 000
630 800 1 000 1 250 1 600 2 000 2 500 Left hand female – double bar 550 to 1 049 mm
Rating (A)
1 1 1 1
2 500 3 200 4 000 5 000 Left hand female – single bar 550 to 1 049 mm
Rating (A)
1 1 1 1 1 1 1
630 800 1 000 1 250 1 600 2 000 2 500 Left hand male – double bar 550 to 1 049 mm
Rating (A)
1 1 1 1
Rating (A)
Rating (A)
1 1 1 1
60390734P 60390736P 60390737P
65390735P 65390736P 65390738P
2 500 3 200 4 000 5 000
Key : How to select the correct configuration of bar The 4th digit of an SCP Cat. No. determines the busbar configuration All examples on this page show 4 conductor versions, ie. 8 or 9; 5 conductor and 200% neutral versions are available by substituting the 4th digit with 4, 5, 6 or 7, as shown below
1 : Standard dimensions 600 + 600 + 600 mm
74
Single bar Double bar
3L + N + PE 8 9
3L + N + FE+ PE 3L + 2N + PE 4 5 6 7
SCP super compact busbar connection interfaces
Single bar – type 1 connection interface
For Legrand cast resin transformers compatibility table p. 101
Selection charts p. 62-65 Dimensions and technical information p. 98-99 Coverplate and bar drilling details p. 100 Technical data p. 112-117
High power busbar from 630 A to 4 000 A with aluminium alloy conductors and from 800 A to 5 000 A with copper conductors SCP complies with IEC 61439-6 (BS EN 61439-6) For connecting the busbar to the cabinet or transformer Pack
Connection interfaces – in-line standard dimensions 300 mm
Cat. Nos.
Pack
Connection interfaces – in-line bespoke dimensions
Cat. Nos.
Please specify required length when ordering (see p.98 for configuration)
Type 1 male – single bar Aluminium
1 1 1 1 1 1 1
60281010P 60281011P 60281012P 60281014P 60281016P 60281017P
1 1 1 1
60391014P 60391016P 60391017P
1 1 1 1 1 1 1
60281000P 60281001P 60281002P 60281004P 60281006P 60281007P
1 1 1 1
60391004P 60391006P 60391007P
Copper
65281010P 65281011P 65281013P 65281015P 65281016P 65281018P
Rating (A)
630 800 1 000 1 250 1 600 2 000 2 500 Type 1 male – double bar Rating (A)
65391015P 65391016P 65391018P
2 500 3 200 4 000 5 000 Type 2 female – single bar Rating (A)
65281000P 65281001P 65281003P 65281005P 65281006P 65281008P
630 800 1 000 1 250 1 600 2 000 2 500 Type 2 female – double bar Rating (A)
65391005P 65391006P 65391008P
2 500 3 200 4 000 5 000
Type 1 male - single bar Aluminium
1 1 1 1 1 1 1
60281030P 60281031P 60281032P 60281034P 60281036P 60281037P
1 1 1 1
60391034P 60391036P 60391037P
1 1 1 1 1 1 1
60281020P 60281021P 60281022P 60281024P 60281026P 60281027P
1 1 1 1
60391024P 60391026P 60391027P
Copper
65281030P 65281031P 65281033P 65281035P 65281036P 65281038P
Rating (A)
630 800 1 000 1 250 1 600 2 000 2 500 Type 1 male - double bar Rating (A)
65391035P 65391036P 65391038P
2 500 3 200 4 000 5 000 Type 2 female - single bar Rating (A)
65281020P 65281021P 65281023P 65281025P 65281026P 65281028P
630 800 1 000 1 250 1 600 2 000 2 500 Type 2 female - double bar Rating (A)
65391025P 65391026P 65391028P
2 500 3 200 4 000 5 000
Key : How to select the correct configuration of bar The 4th digit of an SCP Cat. No. determines the busbar configuration All examples on this page show 4 conductor versions, ie. 8 or 9; 5 conductor and 200% neutral versions are available by substituting the 4th digit with 4, 5, 6 or 7, as shown below
Single bar Double bar
3L + N + PE 8 9
3L + N + FE+ PE 3L + 2N + PE 4 5 6 7
75
SCP super compact busbar connection interfaces + horizontal elbows
Single bar – type 1 connection interface + horizontal elbow
Selection charts p. 62-65 Dimensions and technical information p. 98 Coverplate and bar drilling details p. 100 Technical data p. 112-117
For Legrand cast resin transformers compatibility table p. 101
High power busbar from 630 A to 4 000 A with aluminium alloy conductors and from 800 A to 5 000 A with copper conductors SCP complies with IEC 61439-6 (BS EN 61439-6) For connecting the busbar to the cabinet or transformer Pack
Connection interfaces + horizontal elbows – bespoke dimensions1
Cat. Nos.
Pack
Cat. Nos
.
Please specify required length when ordering (see p. 98 for configuration)
Please specify required length when ordering (see p. 98 for configuration)
Type 3 male – single bar
Type 1 female – single bar Aluminium
1 1 1 1 1 1 1
60281300P 60281301P 60281302P 60281304P 60281306P 60281307P
1 1 1 1
60391304P 60391306P 60391307P
1 1 1 1 1 1 1
60281310P 60281311P 60281312P 60281314P 60281316P 60281317P
1 1 1 1
60391314P 60391316P 60391317P
Copper
65281300P 65281301P 65281303P 65281305P 65281306P 65281308P
Rating (A)
630 800 1 000 1 250 1 600 2 000 2 500 Type 1 female – double bar
Aluminium
1 1 1 1 1 1 1
60281320P 60281321P 60281322P 60281324P 60281326P 60281327P
1 1 1 1
60391324P 60391326P 60391327P
Copper
65281320P 65281321P 65281323P 65281325P 65281326P 65281328P
Rating (A)
65391305P 65391306P 65391308P
2 500 3 200 4 000 5 000 Type 2 female – single bar
65281310P 65281311P 65281313P 65281315P 65281316P 65281318P
65391325P 65391326P 65391328P
2 500 3 200 4 000 5 000
630 800 1 000 1 250 1 600 2 000 2 500 Type 3 male – double bar 2 500 3 200 4 000 5 000 Type 4 male – single bar Rating (A)
1 1 1 1 1 1 1
60281330P 60281331P 60281332P 60281334P 60281336P 60281337P
1 1 1 1
60391334P 60391336P 60391337P
65281330P 65281331P 65281333P 65281335P 65281336P 65281338P
Rating (A)
65391315P 65391316P 65391318P
Rating (A)
Rating (A)
Rating (A)
630 800 1 000 1 250 1 600 2 000 2 500 Type 2 female – double bar
Connection interfaces + horizontal elbows – bespoke dimensions (continued)1
630 800 1 000 1 250 1 600 2 000 2 500 Type 4 male – double bar Rating (A)
65391335P 65391336P 65391338P
2 500 3 200 4 000 5 000
Key : How to select the correct configuration of bar The 4th digit of an SCP Cat. No. determines the busbar configuration All examples on this page show 4 conductor versions, ie. 8 or 9; 5 conductor and 200% neutral versions are available by substituting the 4th digit with 4, 5, 6 or 7, as shown below
Single bar Double bar 1 : Standard dimensions 300 + 300 mm
76
3L + N + PE 8 9
3L + N + FE+ PE 3L + 2N + PE 4 5 6 7
SCP super compact busbar connection interfaces + vertical elbows and feed units
Single bar – type 1 connection interface + vertical elbow Single bar type 1 end feed unit
Selection charts p. 62-65 Dimensions and technical information p. 99 Coverplate and bar drilling details p. 100 Technical data p. 112-117
High power busbar from 630 A to 4 000 A with aluminium alloy conductors and from 800 A to 5 000 A with copper conductors SCP complies with IEC 61439-6 (BS EN 61439-6) For connecting the busbar to the cabinet or transformer End feed units have rear cable input and aluminium gland plate(s) for cable entry – 170 x 410 mm. Single bar 1 plate, double bar 2 plates Pack
Connection interfaces + vertical elbows – bespoke dimensions1
Cat. Nos.
Pack
Connection interfaces + vertical elbows – bespoke dimensions (continued)1
Cat. Nos.
Please specify required length when ordering (see p. 99 for configuration)
Please specify required length when ordering (see p. 99 for configuration)
Type 4 male – single bar
Type 1 female – single bar Aluminium
1 1 1 1 1 1
60281400P 60281401P 60281402P 60281404P 60281406P 60281407P
1 1 1 1
60391404P 60391406P 60391407P
1 1 1 1 1 1 1
60281410P 60281411P 60281412P 60281414P 60281416P 60281417P
1 1 1 1
60391414P 60391416P 60391417P
Copper
65281400P 65281401P 65281403P 65281405P 65281406P 65281408P
Rating (A)
630 800 1 000 1 250 1 600 2 000 2 500 Type 1 female – double bar
Aluminium
1 1 1 1 1 1 1
60281430P 60281431P 60281432P 60281434P 60281436P 60281437P
1 1 1 1
60391434P 60391436P 60391437P
Copper
65281430P 65281431P 65281433P 65281435P 65281436P 65281438P
Rating (A)
65391405P 65391406P 65391408P
2 500 3 200 4 000 5 000 Type 2 female – single bar
65281410P 65281411P 65281413P 65281415P 65281416P 65281418P
Rating (A)
65391415P 65391416P 65391418P
2 500 3 200 4 000 5 000 Type 3 male – single bar Rating (A)
1 1 1 1 1 1 1
60281420P 60281421P 60281422P 60281424P 60281426P 60281427P
1 1 1 1
60391424P 60391426P 60391427P
65281420P 65281421P 65281423P 65281425P 65281426P 65281428P
630 800 1 000 1 250 1 600 2 000 2 500 Type 3 male – double bar Rating (A)
65391425P 65391426P 65391428P
2 500 3 200 4 000 5 000
630 800 1 000 1 250 1 600 2 000 2 500 Type 4 male – double bar Rating (A)
65391435P 65391436P 65391438P
2 500 3 200 4 000 5 000
End feed unit – standard 300 mm
Rating (A)
630 800 1 000 1 250 1 600 2 000 2 500 Type 2 female – double bar
Rating (A)
Type 1 male – single bar Aluminium
1 1 1 1 1 1 1
60281110P 60281111P 60281112P 60281114P 60281116P 60281117P
1 1 1 1
60391114P 60391116P 60391117P
Copper
65281110P 65281111P 65281113P 65281115P 65281116P 65281118P
Rating (A)
630 800 1 000 1 250 1 600 2 000 2 500 Type 1 male – double bar Rating (A)
65391115P 65391116P 65391118P
2 500 3 200 4 000 5 000 Type 2 female – single bar Rating (A)
1 1 1 1 1 1 1
60281100P 60281101P 60281102P 60281104P 60281106P 60281107P
1 1 1 1
60391104P 60391106P 60391107P
65281100P 65281101P 65281103P 65281105P 65281106P 65281108P
630 800 1 000 1 250 1 600 2 000 2 500 Type 2 female – double bar Rating (A)
65391105P 65391106P 65391108P
2 500 3 200 4 000 5 000
1 : Standard dimensions 300 + 300 mm single bar and 450 + 450 mm double bar
77
SCP tap-off boxes – plug-in type 63-630 A with AC21A disconnection on the door
Plug-in boxes can be itted on any length with tap-off outlets irrespective of rating and conductor material
Fuse carrier
24
0
183 Side cable input
3L + N + FE + PE
3L + 2N + PE
63 A
CH22
65285031P
65245021P
65255031P
NH00
65285032P
65245022P
65255032P
160 A
NH00
65285033P
65245023P
65255033P
250 A
NH2
65285034P
65245024P
65255034P
630 A
NH3
65285036P
65245026P
65255036P
With switch disconnector (AC23) and fuse carrier (fuses not included) Tap-off rating
4
57
3L + N + PE
125 A
757
Cover with AC21A disconnection
With fuse carrier (fuses not included) Tap-off rating
Fuse carrier
3L + N + PE
3L + N + FE + PE
3L + 2N + PE
63 A
NH000
65285051P
65245041P
65255051P
125 A
NH00
65285052P
65245042P
65255052P
160 A
NH00
65285053P
65245043P
65255053P
250 A
NH1
65285054P
65245044P
65255054P
400 A
NH2
65285055P
65245045P
65255055P
630 A
NH3
65285076P
65245066P
65255076P
Empty version
From 63 to 160 A Tap-off rating
Cover with AC21A disconnection
3L + N + PE
3L + N + FE + PE
3L + 2N + PE
63 A
65285011P
65245001P
65255011P
125 A
65285012P
65245002P
65255012P
160 A
65285013P
65245003P
65255013P
250 A
65285014P
65245004P
65255014P
630 A
65285016P
65245006P
65255016P
1 034
Fully itted tap-offs c/w 4P Legrand MCCB with rotary handle1 41
0
5
78
Tap-off rating
Breaker rating
286
63 A
125 A Side cable input
160 A 250 A
From 250 to 630 A
630 A
78
3L + N + FE + PE
3L + 2N + PE
40 A
65285013PM4RB
65245003PM4RB
65255013PM4RB
63 A
65285013PM4RC
65245003PM4RC
65255013PM4RC
100 A
65285013PM4RD
65245003PM4RD
65255013PM4RD
125 A
65285013PM4RE
65245003PM4RE
65255013PM4RE
160 A
65285013PM4RF
65245003PM4RF
65255013PM4RF
200 A
65285014PM4RG
65245004PM4RG
65255014PM4RG
250 A
65285014PM4RH
65245004PM4RH
65255014PM4RH
400 A
65285016PM4RI
65245006PM4RI
65255016PM4RI
630 A
65285016PM4RJ
65245006PM4RJ
65255016PM4RJ
1 : For MCCB technical data, see p. 118-125
Dimensions and technical information p. 102-103 Technical data p. 112-117
3L + N + PE
SCP tap-off boxes – plug-in type 125-400 A – bolt-on type 125-1 250 A Plug-in tap-offs 125-1 250 A (remain live with door open) Rear cable input
With switch disconnector (AC23) and fuse carrier (fuses not included)
34
260
320
550
0
Tap-off rating
Fuse carrier
3L + N + PE
3L + N + FE + PE
3L + 2N + PE
125 A
NH00
65282001P
N/A
N/A
250 A
NH1
65282002P
N/A
N/A
400 A
NH2
65282003P
N/A
N/A
0
54
85 20
Bolt-on tap-offs – with switch disconnector (AC23) and fuse carrier 125 A to 1 250 A (fuses not included) The boxes cannot be installed simultaneously on both sides of the same junction The bolted boxes are to be installed directly on the junction when the busbar is disconnected and not energised Dimensions and technical information p. 103. Technical data p. 112-117 Busbar system – aluminium Double bar
Single bar 630 A 800 A 1 000 A 1 250 A
1 600 A
2 000 A
2 500 A
3 200 A
4 000 A
125 A NH00
65281811P
65281812P
65281814P
65391812P
65391813P
65391814P
250 A NH1
65281821P
65281822P
65281824P
65391822P
65391823P
65291824P
400 A NH2
65281831P
65281832P
65281834P
65391832P
65391833P
65291834P
630 A NH3
65286041P
65286042P
65286044P
65396042P
65396043P
65396044P
800 A NH4
65281851P
65281852P
65281854P
65391852P
65391853P
65291854P
1 000 A NH4
65281861P
65281862P
65281864P
65391862P
65391863P
65291864P
1 250 A NH4
65281871P
65281872P
65281874P
65391872P
65391873P
65291874P
Tap-off rating/ fuse carrier
C
E
A
B
D
Busbar system – copper Double bar
Single bar 800 A 1 000 A 1 250 A
1 600 A 2 000 A
2 500 A
3 200 A
4 000 A
5 000 A
125 A NH00
65281811P
65281812P
65281814P
65391812P
65391813P
65391814P
250 A NH1
65281821P
65281822P
65281824P
65391822P
65391823P
65391824P
400 A NH2
65281831P
65281832P
65281834P
65391832P
65391833P
65391834P
630 A NH3
65286041P
65286042P
65286044P
65396042P
65396043P
65396044P
800 A NH4
65281851P
65281852P
65281854P
65391852P
65391853P
65391854P
1 000 A NH4
65281861P
65281862P
65281864P
65391862P
65391863P
65391864P
1 250 A NH4
65281871P
65281872P
65281874P
65391872P
65391873P
65391874P
Tap-off rating/ fuse carrier Dimensions of the box Box rating 125-400 A 630 A 800-1 250 A (A) mm 365 400 450 (B) mm 630 750 1 050 (C) mm 270 280 300 (D) mm 95 115 115 (E) mm 635 680 750
Rated insulating AC voltage Rated impulse withstand voltage Type of rated duty Rated conditional short circuit current
Ui (V)
1 000
Uimp (kV)
12
–
AC23A
(kA)
100 IEC 60947-3
Dimensions and technical information p. 103 Technical data p. 112-117
79
SCP super compact busbar fixing supports for horizontal installation
Single bar – edgeways fixing support
Single bar – flat fixing support
Dimensions and technical information p. 104 Fixing supports for fixing the busbar to the structure of the building
Pack
Cat. Nos. Aluminium busbar
Copper busbar
Suspension brackets for edgeways installation
Pack
Single bar Height : 210 mm
Cat. Nos. Aluminium busbar
Copper busbar
Rating (A)
1 1
65202001
1 1
65202002
1 1
65202004
65202001
630 to 1 250 800 to 1 250 Height : 250 mm
65202002
65202001
1 1
65202013
1 1
65202112
1 1
65202113
65202001
2 000 2 500 Double bar Height : 460 mm
65202013
65222002
1 1
65222003
1 1
65222004
65222002
2 500 3 200 Height : 520 mm
65202112
65222003
Rating (A)
80
65222004
4 000 5 000
2 500 3 200 Height : 490 mm Rating (A)
65202113
3 200 4 000 Height : 530 mm
Rating (A)
3 200 4 000 Height : 560 mm
1 600 to 2 000 1 600 to 2 500 Double bar Height : 430 mm Rating (A)
Rating (A)
1 1
630 to 1 250 800 to 1 250 Height : 315 mm Rating (A)
Rating (A)
65202004
Single bar Height : 190 mm Rating (A)
1 1
Rating (A)
1 600 1 600 to 2 000 Height : 300 mm
Suspension brackets for flat installation
Rating (A)
1 1
65202114 65202114
4 000 5 000
SCP super compact busbar fixing supports for vertical installation
Fixing support with bracket and springs
Fixing support with bracket
Fixing support with springs
Fixing support – bracket only
Dimensions and technical information p. 105-106 Fixing supports for fixing the busbar to the structure of the building For vertical installations and special applications Pack
Fixing supports with bracket and springs
Cat. Nos. Aluminium
Copper
65213711 65213712 65213711 65213712 65213714 65213714
630 to 1 250 1 600 800 to 1 250 1 600 to 2 000 2 000 2 500
Fixing supports with springs
Cat. Nos. Aluminium
Single bar Rating (A)
1 1 1 1 1 1
Pack
Copper
Rating (A)
1 1 1 1 1 1
65213701 65213701 65213702 65213702 65213704 65213704
1 1 1 1 1 1
65213742 65213742 65213743 65213743 65213744 65213744
2 500 3 200 3 200 4 000 4 000 5 000
Rating (A)
1 1 1 1 1 1
65213732 65213732 65213733 65213733 65213734 65213734
Copper
1 1 1 1 1 1
65213721 65213721 65213722 65213722 65213724 65213724
630 to 1 250 800 to 1 250 1 600 1 600 to 2 000 2 000 2 500 Double bar – not anti-seismic rated Rating (A)
1 1 1 1 1 1
65213752 65213752 65213753 65213753 65213754 65213754
Aluminium
Single bar – anti-seismic rated Rating (A)
2 500 3 200 3 200 4 000 4 000 5 000
2 500 3 200 3 200 4 000 4 000 5 000
Fixing supports – bracket only
Fixing supports with bracket Aluminium
630 to 1 250 800 to 1 250 1 600 1 600 to 2 000 2 000 2 500 Double bar
Double bar Rating (A)
Single bar
Copper
Single bar Rating (A)
1 1 1 1 1 1
65213761 65213761 65213762 65213762 65213764 65213764
630 to 1 250 800 to 1 250 1 600 1 600 to 2 000 2 000 2 500 Double bar Rating (A)
1 1 1 1 1 1
65213772 65213772 65213773 65213773 65213774 65213774
2 500 3 200 3 200 4 000 4 000 5 000
Double bar – anti-seismic rated Rating (A)
1 1 1 1 1 1
65213792 65213792 65213793 65213793 65213794 65213794
2 500 3 200 3 200 4 000 4 000 5 000
81
SCP super compact busbar
SCP super compact busbar
fixing supports for vertical installation (continued)
protective bellows
Protective covers for outdoor applications available on request Contact us on +44 (0) 370 608 9020 Fixing support for Naval applications Protective bellows – single bar
Dimensions and technical information p. 105-106 Fixing supports for fixing the busbar to the structure of the building
Pack
Fixing supports for naval applications
Cat. Nos. Aluminium
Copper
Dimensions and technical information p. 107 High power busbar from 630 A to 4 000 A with aluminium alloy conductors and from 800 A to 5 000 A with copper conductors SCP complies with IEC 61439-6 Pack
Protective bellows
Cat. Nos.
Recommended for protection of the interface connection on panel boards, dry-type transformer with enclosure and oil-type transformers For Legrand cast resin transformers, custom-made connections are available upon request (see p. 83)
Double bar Rating (A)
1 1 1 1 1 1
65213782 65213782 65213783 65213783 65213784 65213784
2 500 3 200 3 200 4 000 4 000 5 000
Aluminium
Copper
Single bar Rating (A)
1
SF766040 SF766040
1
630 to 2 000 800 to 2 500 Double bar Rating (A)
1 1
82
SF927140 SF927140
2 500 to 4 000 3 200 to 5 000
SCP super compact busbar transformer connections
Transformer Flexible braid connection
Installation example
Dimensions and technical information p. 108 High power busbar from 630 A to 4 000 A with aluminium alloy conductors and from 800 A to 5 000 A with copper conductors SCP complies with IEC 61439-6 (BS EN 61439-6) Pack
Flexible braid connections
Cat. Nos.
Pack
(continued)
When ordering, please specify hole dimensions on transformer side (A, B, Ø D) and length L (see p. 108) Aluminium
1 1 1 1 1 1 1 1 1 1
FC100010 FC100010 FC200010 FC300010 FC500010 FC600010 FC400010 FC500010 FC600010
Copper
FC100010 FC200010 FC300010 FC500010 FC600010 FC400010 FC500010 FC600010 FC700010
Length : 300 - 450 mm Rating (A)
No. of braids per phase
630 800 1 000 1 250 1 600 2 000 2 500 3 200 4 000 5 000
1 1 1 1 1 1 2 2 2 2
Length : 451 - 600 mm 1 1 1 1 1 1 1 1 1 1
FC100020 FC100020 FC200020 FC300020 FC500020 FC600020 FC400020 FC500020 FC600020
FC100020 FC200020 FC300020 FC500020 FC600020 FC400020 FC500020 FC600020 FC700020
Rating (A)
No. of braids per phase
630 800 1 000 1 250 1 600 2 000 2 500 3 200 4 000 5 000
1 1 1 1 1 1 2 2 2 2
Flexible braid connections
Cat. Nos. Aluminium
1 1 1 1 1 1 1 1 1 1
FC100030 FC100030 FC200030 FC300030 FC500030 FC600030 FC400030 FC500030 FC600030
Copper
FC100030 FC200030 FC300030 FC500030 FC600030 FC400030 FC500030 FC600030 FC700030
Length : 601 - 750 mm Rating (A)
No. of braids per phase
630 800 1 000 1 250 1 600 2 000 2 500 3 200 4 000 5 000
1 1 1 1 1 1 2 2 2 2
Length : over 750 mm 1 1 1 1 1 1 1 1 1 1
FC100099 FC100099 FC200099 FC300099 FC500099 FC600099 FC400099 FC500099 FC600099
FC100099 FC200099 FC300099 FC500099 FC600099 FC400099 FC500099 FC600099 FC700099
Rating (A)
No. of braids per phase
630 800 1 000 1 250 1 600 2 000 2 500 3 200 4 000 5 000
1 1 1 1 1 1 2 2 2 2
83
SCP super compact busbar technical information n General features
n Standard versions
SCP complies with IEC 61439-6 (BS EN 61439-6) The outer casing of the SCP range consists of four C-ribbed section bars, bordered and riveted (thickness 1·5 mm), with excellent mechanical, electric and heat loss efficiency The sheet metal is manufactured from galvanised steel, treated according to UNI EN 10327 and painted with RAL 7035 resins with a high resistance to chemical agents The standard degree of protection is IP 55 and with certain accessories (see p. 82), it can be installed outdoors. IP 65 (only for transport of energy) is available on request, contact us on +44 (0) 370 608 9020 The busbar conductors have a rectangular cross-section with rounded corners. There are two versions : - Electrolytic copper ETP 99.9 UNI EN 13601 - Aluminum alloy treated over the entire surface with 5 galvanic processes (copper plating + tin plating) The insulation between bars is ensured by a double sheath made with polyester film (total thickness 0·4 mm) Class B (130° C), Class F (155° C) thermal resistance available on request – contact us on +44 (0) 370 608 9020 All plastic components have a V1 self-extinguishing degree (as per UL94), are fire retardant and comply with the glow-wire test according to standards. The SCP range is halogen free In order to facilitate storage and reduce installation time, the straight lengths and system components of the SCP range are supplied with a pre-installed monobloc for fast, easy and secure connection of the system. The junction contact is ensured by tin-plated aluminium for SCP Al and copper for SCP Cu for each phase, insulated with red Class F thermoset plastic material The monobloc has shearhead bolts : after tightening the nuts with a standard wrench, the outer head will break at the correct torque value, giving you the certainty that the connection has been made properly to guarantee safety and maximum performance over time Finally, in order to completely verify the insulation level, every component with a monobloc undergoes an insulation test (phasephase, phase-PE) at the factory with a test voltage of 3 500 V for 1.5 seconds
SCP line with 4 conductors 3L + N + PE, 3L + PEN, 3L + FE + PE Note : for dimension H, see technical data section p. 112-117 PE : Protection earth FE : Functional earth (clean earth)
n Certificates SCP has been given Type-Approval Certifications by the most prestigious Electro-technical agencies :
H N L1 L2 L3 PE
double bar
single bar SCP5 line with 5 conductors 3L + N + FE + PE Note : For dimension H, see technical data section p. 112-117 PE : Protection earth FE : Functional earth (clean earth)
H
140
FE N L1 L2 L3 PE
single bar
double bar
SCP2N 200% neutral line 3L + 2N + PE Note : For dimension H, see technical data section p. 112-117 PE : Protection earth FE : Functional earth (clean earth) 140
H
• Certificate of Compliance with Standards IEC 61439-6 (BS EN 61439-6) (ACAE - LOVAG) • ABS Type-Approval (American Bureau of Standard) • EAC Type-Approval (Russia) • S120 fire resistance measurements • Noise measurements (CESI) • Fire resistance measurements with Fire Barrier • Electromagnetic emissions measurements • Mechanical vibration resistance measurements (Dynamic Test - ENEL HYDRO)
130
2N L1 L2 L3 PE
single bar
double bar
Special versions are available on request, contact us on +44 (0) 370 608 9020
All dimensions (mm) are nominal
84
n Electric design criteria
Ue ≤ 1 000 V
630 < In < 5 000 A
36 < lcw < 160 kA
–5 < T < + 50 °C
IP = 55
SCP
Busbar material selection
COPPER
ALUMINIUM
800 < In < 5 000 A
630 < In < 4 000 A
Single bar
Double bar
Single bar
Double bar
800 < In < 2 500 A
3 200 < In < 5000 A
630 < In < 2 000 A
2 500 < In < 4 000 A
85
SCP super compact busbar technical information n Joule effect losses in busbars Losses due to the Joule effect are essentially caused by the electrical resistance of the busbar Lost energy is transformed into heat and contributes to the heating of the conduit of the environment The calculation of power loss is useful data for correct sizing of the building air conditioning system Three-phase regime losses are : Pj =
3 • Rt • Ib2 • L 1 000
In single-phase regime : Pj =
2 • Rt •Ib2 • L 1 000
Where : Ib = utilisation current (A) Rt = phase resistance for unit of length of the busbar trunking system, measured at thermal regime (mΩ/m) L = busbar length (m) For accurate calculation, losses must be assessed trunk by trunk, taking into account the transiting currents ; for example, in the case of the distribution of the loads represented in the table below Length 1st trunk 2nd trunk 3rd trunk
L1 L2-L1 L3-L2
Transiting current I1+I2+I3 I2+I3 I3
Losses P1 = 3RtL1(I1+I2+I3)2 P2 = 3Rt(L2-L1) (I2+I3)2 P3 = 3Rt(L3-L2) (I3)2
Total losses in the busbar trunking system Pt = P1 + P2 + P3 L3 L2 L1
I1+I2+I3
I2+I3
I3
l1
l2 L
L
n Losses based on the installation method Thermal dispersion, rating and IP protection degree are independent from the type of installation (edgeways, flat, vertical) This means that it is possible to install the SCP busbar trunking system as preferred, without having to consider a possible system downgrade Flat
86
Edgeways
l3 L
n Overload protection Busbar overload protection is ensured following the same criteria used for cables. It will be necessary to check the relationship : Ib ≤ In ≤ Iz Where : Ib = circuit utilisation current In = switch rated current Iz = rating at permanent cable regime Ib Iz
1.45 Iz I
The lb utilisation current in a 3 phase system is calculated based on the following formula : Pt•α•β•d Ib = (A) √3•Ue•cosϕ medium Where : Pt d
= sum of the active powers of the loads installed (W) = power supply factor equal to 1 if the trunking is : •only powered from one side •powered from the centre or from both ends at the same time Ue = operating voltage in (V) cosϕm = average power factor of the loads Ib = utilisation current (A) α = diversity coefficient of the loads (.) β = coefficient of utilisation of the loads (.) The ambient temperature where the busbar trunking system is installed impacts on its rating During the design stages, it is necessary to multiply the rating value at the reference temperature by a correction coefficient referred to the final operating temperature All Zucchini products have been sized and tested for an average ambient temperature of 40 °C. For installation in environments with average daily temperatures lower than 40 °C, the rated current of the busbar must be multiplied by a kt factor, which is higher than the unit for temperatures lower than 40 °C, and lower than the unit if the ambient temperature is higher than 40 °C Iz = Iz0 · Kt Where : • Iz0 is the current that the busbar trunking system can carry for an indefinite time at its reference temperature (40 °C) • Kt is the correction coefficient for ambient temperature values other than the reference temperature, as shown in the following table Kt correction coefficient for ambient temperature other than 40°C Ambient temperature (°C)
15
20
25
30
35
40
45
50
55
60
kt thermal correction factor
1·15
1·12
1·08
1·05
1·025
1
0·975
0·95
0·93
0·89
87
SCP super compact busbar technical information n Selection of the busbar trunking system based on voltage drop If the line is particularly long (> 100 m), it will be necessary to check the value of the voltage drop. For systems with power factor (cosϕm) not lower than 0·8 the voltage loss can be calculated using the following formulas : Three phase system ∆v =
The distribution factor of the current ‘b’ b=1
b•√3•Ib•L•(Rt•cosϕm + x•sinϕm) b=2
1 000 Single phase system ∆v =
Calculation of the voltage drop with loads not evenly distributed (continued) The current distribution factor ‘b’ depends on how the circuit is fed and on the distribution of the electric loads along the busbar
b=4
b•2•Ib•L•(Rt•cosϕm + x•sinϕm) 1 000
b=4
The percentage voltage drop can be obtained from : ∆v
b=8
100
∆v% =
•
Supplies at one end and load at the end of the line Supplies at one end and with load evenly distributed Supplies at both ends and with load evenly distributed Central supply with loads at both ends
Ib
Ib L
Ib L Ib
Ib L Ib Ib 2
Central supply with load evenly distributed
Ib 2
L Ib
Vr Example : SCP 2 000 A Al for rising main feed
Where Vr is the system rated voltage In order to limit the voltage drop in very long busbar trunking systems, it is possible to allow for a power supply at an intermediate position, rather than at the terminal point
Ib b k Cosϕ L Vn
Loads
27·3•10-6•1 600•100 ∆v% = 1· ·100 = 1·09% 400
Loads Busbar trunking system intermediate power supply point
Calculation of the voltage drop with loads not evenly distributed If the load cannot be considered evenly distributed, the voltage drop may be determined more accurately using the relationships shown below For the distribution of three phase loads, the voltage drop is calculated using the following formula, on the assumption (generally verified) that the section of busbar trunking is consistent : ∆v = √3 [Rt (I1L1cosϕ1 + I2L2 cosϕ2 + I3L3 cosϕ3) + x (I1L1sinϕ1 + I2L2 sinϕ2 + I3L3 sinϕ3)] In general terms this becomes : ∆v =
√3(Rt•∑Ii•Li•cosϕmi + x•∑Ii•Li•sinϕmi) 1.000
If the three phase system and the power factor are not lower than cosϕ = 0·7, the voltage loss may be calculated using the voltage drop coefficient shown in the table opposite k•Ib•L ∆v% = 2b•
·100 Vn L3
L1
L2
l1 L
88
l2 L
= 1 600 A operating current = 2 load evenly distributed = 27·3, see technical data table, p. 112-117 (SCP 2 000 A Al cosϕ = 0·85) = 0·85 = 100 m line length = 400 V operating voltage
l3 L
Legend: Ib Vn L ∆v% b k cosϕ m x Rt cosϕ mi li Li
= the current that supplies the busbar (A) = the voltage power supply of the busbar (V) = the length of the busbar (m) = the voltage drop percentage = the distribution factor of the current = corresponding voltage drop factor a cosϕ (V/m/A) (see technical data table, p. 112-117) = average power factor of the loads = phase reactance by unit of length of the busbar (mΩ/m) = phase resistance by unit of length of the busbar (mΩ/m) = i-th load average power factor = i-th load current (A) = distance of the i-th load from the origin of the busbar trunking system
n Short circuit withstand
n Short circuit withstand (continued)
The IEC 64-8 standard indicates that, for the protection of the circuits of the system, it is necessary to allow for devices aimed at interrupting short circuit currents before these become dangerous due to the thermal and mechanical effects generated in the conductors and the connections. In order to size the electric system and the protection devices correctly, it is necessary to know the value of the estimated short circuit current at the point where this is to be created. This value enables selection of the correct protection devices based on their own tripping and closing powers, and to check the resistance to electrodynamic stress of the busbar supports installed in control panels, and/ or of the busbar trunking systems
Analytical determination of short circuit currents In order to calculate the value of the estimated short circuit current at any point of the circuit, it is sufficient to apply the formulas shown below, knowing the impedance calculated at the origin of the system up to the point being assessed. In the formulas shown below, the value of the short circuit power is considered infinite and the short circuit impedance is equal to 0. This makes it possible to define short circuit current values higher than the actual ones, but generally acceptable
Characterisation of short circuit current The estimated short circuit current at a point of the user system is the current that would occur if at the considered point a connection of negligible resistance was created between conductors under voltage. The magnitude of this current is an estimated value that represents the worst possible condition (null fault impedance, tripping time long enough to enable the current to reach the maximum theoretical values). In reality, the short circuit always occurs with significantly lower effective current values Short circuit current
Current (I)
L (m)
S (mm2) P (kVA) Line resistance RL = r • L
RL r L
= resistance of the line upstream (m) = specific line resistance (m/m) = upstream line length (m)
Line reactance XL = x • L
XL x
= upstream line reactance (m) = specific line reactance (m/m)
TRANSFORMER resistance 1 000 Pcu RE = 3 In2
RE Pcu In
= transformer secondary equivalent resistance (m) = transformer COPPER losses (W) = transformer rated current (A)
TRANSFORMER impedance Vcc% V2c ZE = 100 P
ZE = transformer secondary equivalent impedance (m) Vc = phase voltage (V) Vcc% = percentage short circuit voltage P = transformer power (kVA)
Unidirectional component
Time (t) Symmetric component
TRANSFORMER reactance
The intensity of the estimated short circuit current essentially depends on the following factors : • power of the cabin TRANSFORMER, meaning that the higher the power, the higher the current • length of the line upstream the fault, in the sense that the longer the line, the lower the current
2 Icc In Time (t)
In three phase circuits reale with neutral it is possible to have three different Andamento types of short circuit : • phase-phase • phase-neutral • balanced three phase (most demanding condition) The formula for the calculation of the symmetric component is : E ZE+ZL
Where : • E = the phase voltage • ZE = the secondary equivalent impedance of the TRANSFORMER measured between the phase and the neutral • ZL = the impedance of the phase conductor only ZE ZE
ZE
Icc3~
3 E 2ZE + 2ZL
IccFN =
E ZE + 2ZL
Icc3~ =
E ZE + ZL
IccFN
IccFF
E = phase voltage
IccFF =
XE
= transformer secondary equivalent reactance (m)
Zcc
= total short circuit impedance (m)
Icc
= symmetric component of the short circuit current (kA)
Short circuit impedance Zcc = √(RL + RE)2 + (XL + XE)2 Estimated short circuit current Vc Icc = √3 Zcc
Current (I)
Icc =
XE = √ ZE2 – RE2
Aluminium Rating (A)
kA 3 phase lcw1
kA 3 phase lpk
kA 1 phase lcw1
kA 1 phase lpk
630 800 1 000 1 250 1 600 2 000 2 500 3 200 4 000
36 42 50 75 80 80 150 160 160
76 88 110 165 176 176 330 352 352
22 25 30 45 48 48 90 96 96
48 55 66 99 106 106 198 211 211
Rating (A)
kA 3 phase lcw1
kA 3 phase lpk
kA 1 phase lcw1
kA 1 phase lpk
800 1 000 1 250 1 600 2 000 2 500 3 200 4 000 5 000
45 50 60 85 88 88 170 176 176
95 110 132 187 194 194 374 387 387
27 30 36 51 53 53 102 106 106
57 66 79 112 116 116 224 232 232
Copper
1 All: dimensions lcw for 1 second (mm) are nominal
89
SCP super compact busbar technical information n Harmonics In a distribution system, currents and voltages should have a perfectly sinusoidal shape. However, in practice the equipment contains electric devices such as changeover devices or dimmers that make the load not linear The currents absorbed, although at regular intervals and with frequencies equal to that of the rated voltage, sometimes have a non-sinusoidal wave form, which has the following negative effects : •worsening of the power factor •heating of the neutral •additional losses in electric machinery (transformers and motors) •instable operation of the protection elements (thermal magnetic and earth leakage circuit breakers) In industrial plants these conditions have been occurring for a long time. However, they are now occurring more and more in service sector distribution systems, where, from backbone distribution (which uses 3 phase lines), single phase loads are often distributed, which contributes to increasing the unbalance of the electric system Each type of non-sinusoidal periodical wave may be split into a more or less large number of sinusoids (called harmonic components) A deformed current at a frequency of 50 Hz, like the example represented by the magenta line on the figure, consists of many sinusoidal currents with frequency of 50 Hz (fundamental), 100 Hz (second harmonic component), 150 Hz (third harmonic), and so on The presence of current harmonics represents an important problem, causing overload conditions both on phase conductors, and on any neutral conductor, and results in the reduction of the conductor’s permitted load Measurement of harmonic distortion carried out with a network analyser u
t
Fundamental (50 Hz)
Fifth harmonic (250 Hz)
Third harmonic (150 Hz)
Resulting wave shape
Distortion of the individual harmonics
100%
Total distortion (THD) = 25.5% H
THD% = 10 0 23%
( ) Uh
h=2
U1
2
= 100
( ) ( ) 23
2
100
+
11
100
2
= 25.5 %
11%
50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 Hz
Choice of rating when in the presence of harmonics When in the presence of harmonics, and when using the chosen Int rated current, the SCP busbar to be used shall have the rating specified in the table below Rated current (A)
630 A
800 A
1 000 A 1 250 A 1 600 A 2 000 A 2 500 A 3 200 A 4 000 A 5 000 A
SCP busbar to be used THD ≤ 15%
630
800
1 000
1 250
1 600
2 000
2 500
3 200
4 000
5 000
15% < THD ≤ 33%
800
1 000
1 250
1 600
2 000
2 500
3 200
4 000
5 000
–
1 000
1 250
1 600
2 000
2 500
3 200
4 000
5 000
–
–
THD > 33%
Note 200% neutral versions are available for systems with harmonics present on the neutral
90
n Measurement of magnetic induction
n Measurement of magnetic induction (continued)
Since 1994, with a study carried out by Chalmers University of Technology of Goteborg, Legrand has taken an interest in the issues linked with the electromagnetic emissions in their Zucchini products, keeping at the forefront of the latest legislative directive, which has only recently imposed the quality standards that were already widely met by Zucchini busbar trunking systems The ACAE (Association for the Certification of Electric and Electronic Equipment) certified internal laboratory is capable of carrying out the measurement of the electromagnetic emissions of busbar trunking systems. This measurement is nowadays one of the tests to which the products are subjected before they reach the market The busbar trunking system in itself already minimises electromagnetic emissions, which are much lower when compared with those generated by cables with the same current intensity It is a well-known fact that the electromagnetic field is the result of the superimposition of two fields : the electric and the magnetic field The first is totally shielded by the equipotential metal casing of the busbar trunking system, while the second is very low due to the intrinsic characteristic of the busbar trunking system. More precisely, due to the fact that busbar conductors are extremely close inside the busbar package, the three busbar conductors, crossed by three balanced currents displaced by 120°, induce fields that tend to overlap, cancelling one another, therefore resulting in an extremely low external impact However, also in conditions of imperfect current balance, the metal casing of the busbar trunking system is capable of reducing most of the magnetic field, which otherwise would spread through the surrounding environment
The high quality standard guaranteed by busbar trunking systems can be further appreciated by comparing the emission values measured against those of other commonly used equipment, as taken from table 7·1 of IEC 211-6 standard The measurements obtained on aluminium SCP busbar trunking systems with ratings of 2 500 A – carried out in compliance with the requirements of the technical product standard IEC 61439-6 (BS EN 61439-6) – show that the magnetic induction generated by the busbar is in the range of 1·5 - 2 μT at a distance of one metre from the busbar itself These values also apply near the junction, which is considered the critical point due to the wider distance between the busbar conductors in this position
Testing at Legrand’s laboratory in Italy for the approval certification of Zucchini SCP busbar trunking systems
Levels of exposure to industrial frequency magnetic field sources (table 7.1 from IEC 211-6 standard) Source Electric shaver Hairdryer Blender 12 V, 20 W halogen lamp Aerosol therapy equipment Electric blanket 21 inch television set Washing machine Dishwasher Electric oven 600 W drill 100 W welding machine 225 W grinder 1 100 W compressor 2 150 W arc welding machine 75 MW, 55-65 kA, 150 t arc oven Electric scalpel Battery charger Echograph Projector
Magnetic induction (µT)
Distance
150-240 1-13 0·9 0·5 20-50 2 0·3 3·4 0·05 0·4 2 14·5 0·8 8·2 23·2 100-270 2·9 22·9 0·8 2·3
on the face 10-20 cm 40 cm 30 cm 20-30 cm on contact 50 cm 50 cm 50 cm 20 cm on the chest on the chest 40 cm 40 cm 40 cm in proximity in proximity in proximity operator position 20 cm
One-dimensional trend of the magnetic induction near the junction. The blue dash shows the ‘objective’ level and the red dash shows the ‘quality objective’ required by law B (μ T) 25
Objective level The laboratory tests carried out show how the magnetic induction emitted by SCP busbar trunking systems, measured at a distance of approximately one metre, is well below the critical value of 3 μT With Legislative Decree DPCM dated 8/7/2003, Italian law set the first exposure limit at 100 μT In addition, in locations where attendance is expected for no less than four hours a day, an attention value of 10 μT has been set, to avoid possible long term effects on health In the decree, the 3 μT threshold is indicated as the ‘quality objective’. However, as the product is intended for the European and world market, low magnetic emission is a fundamental point that cannot be disregarded, to ensure a presence in foreign countries : one example of this is Germany, where for over 10 years the regulation has set a cautionary limit of 3 μT as the maximum permitted threshold in certain structures, for example hospitals, so much so that in these types of environments the busbar trunking system has become a mandatory choice, as well as a high quality one
Quality objective level
20
15
10
5
0 20
40
60
80
100
120
CM
All dimensions (mm) are nominal
91
SCP super compact busbar technical information n Example of measurement of the level of the magnetic field on the busbar Transversal section (parallel to the measurement plane) of the SCP busbar on which the test is carried out
Graphic representation of an SCP double busbar 3 m straight length Shown in green is the orthogonal plane of the element on which the magnetic inductions referred to in the following graphs are measured
Detailed view
92
n Magnetic induction graphs at 60 cm from the busbar The graphs shown refer to the measurements carried out on the aluminium SCP prefabricated electric busbar with rated load of 2 500 A, crossed by a 2 500 A current The measurements carried out at 60 cm from the junction are to be considered as higher due to the magnetic induction generated by the busbar power supply : due to the intrinsic geometry of the measurement laboratory structure, it must be assumed that the measurement area is also affected by a magnetic induction of no less than 1·5 μT generated by the line power supply In view of this observation, in case of actual operating line the quality objective indicated by Legislative Decree DPCM dated 8/7/2003 is widely met at less than one metre from the axis of the busbar
n Magnetic induction graphs at 60 cm from the busbar (continued) As it can be seen on the graph below, up to a distance of approximately 40 cm from the axis of the busbar, the field appears generated by two separate sources. This is due to the fact that the busbar being analysed consists of two series of busbar conductors set in parallel at a distance of approximately 5 cm from each other The cells making up the measurement grid are 20 cm squares
3 dimensional development of magnetic induction around the busbar at 60 cm from the junction
12 11 10 9 8 7 6 5 4 3 2 1 0
10 1211 1413 15 16
12 11 10 9 8 7 6 5 4 3 2 1 0
1 3 2 5 4 6 7 98
8 9 10 11 12 13 14 15 16
0
12 11·6 11·2 10·8 10·4 10 9·6 9·2 8·8 8·4 8 7·6 7·2 6·8 6·4 6 5·6 5·2 4·8 4·4 4 3·6 3·2 2·8 2·4 2 1·6 1·2 0·8 0·4
y
x
2 dimensional map of the magnetic induction around the busbar at 60 cm from the junction At the centre of the graphic is a schematic representation of the busbar
12 11·6 11·2 10·8 10·4 10 9·6 9·2 8·8 8·4 8 7·6 7·2 6·8 6·4 6 5·6 5·2 4·8 4·4 4 3·6 3·2 2·8 2·4 2 1·6 1·2 0·8 0·4
All dimensions (mm) are nominal
93
SCP super compact busbar technical information n Graphs showing magnetic induction near the junction It is considered important to show, side by side with the results relating to straight lengths, the results of the measurement carried nearby the electro-mechanic junction of the busbar length. This location may in fact be considered critical, as here magnetic induction is higher due to the higher distance between the busbar conductors corresponding to the various phases of the line
n Graphs showing magnetic induction near the junction (continued) 2 dimensional map of magnetic induction near the junction At the centre of the graphic is a schematic representation of the busbar
Tridimensional development of magnetic induction near the joint
23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
24 23·2 22·4 21·6 20·8 20 19·2 18·4 17·6 16·8 16 15·2 14·4 13·6 12·8 12 11·2 10·4 9·6 8·8 8 7·2 6·4 5·6 4·8 4 3·2 2·4 1·6 0·8
y
x
24 23·2 22·4 21·6 20·8 20 19·2 18·4 17·6 16·8 16 15·2 14·4 13·6 12·8 12 11·2 10·4 9·6 8·8 8 7·2 6·4 5·6 4·8 4 3·2 2·4 1·6 0·8
All dimensions (mm) are nominal
94
n Feeder lengths
n Transposition lengths
10
H
In runs exceeding 100 m it is recommended to include two transposition lengths to balance mutual phase reactance and electric impedance (one at 1/3 and one at 2/3 distance of the run)
00
30
(L)
Dimension H changes with the rating and is specified on p. 112-117 Neutral rotation can be used when the sequence of the distribution board phases is different to that of the transformer For more information please contact us on +44 (0) 370 608 9020 10
00
Minimum and maximum dimensions of single and double bars Aluminium Copper (L) min./max. (mm)
H
Dimension H changes with the rating, and is specified on p. 112-117
12
630 A to 4 000 A 800 A to 5 000 A 1 000 / 3 000
N
1
2
N
3
1
2
3
n Distribution lengths
L)
0(
0 30
0
85
Phase transposition
10
H
0
65
10
0
0
00
65
10 N
1
2
1
2
3
N
H
85
3
Dimension H changes with the rating, and is specified on p. 112-117 Neutral rotation Minimum and maximum dimensions of single and double bars Aluminium Copper (L) min./max. (mm)
630 A to 4 000 A 800 A to 5 000 A 1 000 / 3 000
n End stops Maintain IP 55 protection at the end of a run
n Expansion lengths Absorb the thermal expansion during normal use that, on long runs, would otherwise cumulate and put abnormal force on the connection points
10
H
5
Expansion lengths should be placed in straight runs of more than 40 m L) 0( and repeated every 40 m 00
17
3
e.g. 70 m straight section should contain 1 expansion length in the middle
e.g. 120 m straight section should contain 2 expansion lengths, spaced every 40 m
All dimensions (mm) are nominal
95
SCP super compact busbar technical information n Fire barriers
n Direction changes
620
Left hand
10
≥ 200
Vertical elbow – standard dimensions
No fire barrier
No fire barrier
≥ 200
Fig. 1 300 450
B A
B
211
Right hand
130
No fire barrier ≥ 200
H
H + 81
A
0 30 0 45
620
B
A
Fig. 2 Dimension H changes with the rating, and is specified on p. 112-117 The dimensions refer to standard elbows (bold = double bar) Vertical elbow – bespoke dimensions Please specify required dimensions when ordering Minimum and maximum dimensions of single bar When ordering, please specify the length that will be equipped with an internal fire barrier Due to the geometry of the models 800 A to 2 000 A in aluminium and 1 000 A to 2 500 A in copper, the internal fire barrier is not needed The external fire barrier can be used on any trunking component in compliance with the operating instructions specified in figures 1 and 2 Dimension H changes with the rating and is specified on p. 112-117
n Direction changes Horizontal elbow – standard dimensions Right hand A 0
30
B
30
B
A
Aluminium Copper (A) min./max. (mm) (B) min./max. (mm)
630 A to 2 000 A 800 A to 2 500 A 300 / 1 299 300 / 1 299
Minimum and maximum dimensions of double bar Aluminium Copper (A) min./max. (mm) (B) min./max. (mm)
2 500 A to 4 000 A 3 200 A to 5 000 A 450 / 1 449 450 / 1 449
0
Double horizontal elbow – standard dimensions 10
C
Left hand
B
A
C
10
A 0
A
H
Right + left hand
30 B 0
0
30
B
30
Left + right hand C
Dimension H changes with the rating and is specified on p. 112-117 The dimensions refer to standard elbows B
Horizontal elbow – bespoke dimensions Please specify required dimensions when ordering
H
A
Minimum and maximum dimensions of single and double bars Aluminium Copper (A) min./max. (mm) (B) min./max. (mm)
630 A to 4 000 A 800 A to 5 000 A 250 / 1 299 250 / 1 299
Dimension H changes with the rating, and is specified on p. 112-117 The dimensions refer to standard elbows Double horizontal elbow – bespoke dimensions Please specify required dimensions when ordering Minimum and maximum dimensions of single and double bars Aluminium Copper (A) min./max. (mm) (B) min./max. (mm) (C) min./max. (mm) All dimensions (mm) are nominal
96
630 A to 4 000 A 800 A to 5 000 A 250 / 1 299 50 / 599 250 / 1 299
Double vertical elbow – standard dimensions
Vertical tees – standard dimensions Left + right hand
300 450
0 30 0 60
B
B
10
B
C
A 0 30 0 60
A
300 600
10
C
A
10
B
H
Right + left hand 0 30 0 45
H
C
0 30 0 45
C
A
Right hand - female
Dimension H changes with the rating, and is specified on p. 112-117 The dimensions refer to standard elbows (bold = double bar)
Right hand - male
B
B
A
A C
Double vertical elbow – bespoke dimensions
C
Please specify required dimensions when ordering Minimum and maximum dimensions of single bar Aluminium Copper (A) min./max. (mm) (B) min./max. (mm) (C) min./max. (mm)
630 A to 2 000 A 800 A to 2 500 A 300 / 1 299 50 / 599 300 / 1 299
Minimum and maximum dimensions of double bar Aluminium Copper (A) min./max. (mm) (B) min./max. (mm) (C) min./max. (mm)
2 500 A to 4 000 A 3 200 A to 5 000 A 450 / 1 449 50 / 899 450 / 1 449
Left hand - male
Left hand - female C
C
B B
A
A
Dimension H changes with the rating, and is specified on p. 112-117 The dimensions refer to standard tees (bold = double bar) Vertical tees – bespoke dimensions Please specify required dimensions when ordering Minimum and maximum dimensions of single bar Aluminium Copper (A) min./max. (mm) (B) min./max. (mm) (C) min./max. (mm)
630 A to 2 000 A 800 A to 2 500 A 250 / 1 299 200 / 599 300 / 1 299
Minimum and maximum dimensions of double bar Aluminium Copper (A) min./max. (mm) (B) min./max. (mm) (C) min./max. (mm)
2 500 A to 4 000 A 3 200 A to 5 000 A 250 / 1 449 330 / 749 450 / 1 449
All dimensions (mm) are nominal
97
SCP super compact busbar technical information n Direction changes (continued) Horizontal tees – standard dimensions
n Connection interfaces – in-line Standard dimensions 10
10
0
10
0
B 00
6
C
60
10
0
A 0 30
0
(2)
A 0
60
10
0
20
(1) H
U
H
Non-standard centre distance Dimensions to be provided when requesting a nonstandard centre distance
D E F G
Right hand – female
Right hand – male
B
Type 1 – male
B
A
A
U
A C
A
C
Left hand – male
Type 2 – female
U
Left hand – female C
C
Dimension H changes with the rating, and is specified on p. 112-117 See p. 100 for dimensions of cover plate (1) and bars (2) Connection interfaces – in-line bespoke dimensions Please specify required dimensions when ordering
B
B A
Minimum and maximum dimensions of single and double bars
A
Aluminium Copper (A) min. / max. (mm) (U) min. / max. (mm)
Dimension H changes with the rating, and is specified on p. 112-117 The dimensions refer to standard tees (bold = double bar) Horizontal tees – bespoke dimensions Please specify required dimensions when ordering
630 A to 4 000 A 800 A to 5 000 A 300 / 1 299 150 / 400
n Connection interfaces + horizontal elbows A
0
30
U
Minimum and maximum dimensions of single and double bars 630 A to 4 000 A 800 A to 5 000 A 550 / 1 049 550 / 1 049 550 / 1 049
10
10
0
H
Aluminium Copper (A) min. / max. (mm) (B) min. / max. (mm) (C) min. / max. (mm)
30 B 0
0
20
10
0
(1)
10
0
(2)
Type 1 – female A U
Type 2 – female
B
Type 3 – male
U
Type 4 – male
U
B
U B
A A
A
B
Dimension H changes with the rating and is specified on p. 112-117 The dimensions are referred to standard elements See p. 100 for dimensions of cover plate (1) and bars (2) Connection interfaces + horizontal elbows – bespoke dimensions Please specify required dimensions when ordering Minimum and maximum dimensions of single and double bars
All dimensions (mm) are nominal
98
Aluminium Copper (A) min. / max. (mm) (B) min. / max. (mm) (U) min. / max. (mm)
630 A to 4 000 A 800 A to 5 000 A 150 / 1 299 250 / 1 299 150 / 400
n Connection interfaces + vertical elbows
n Feed units End feed unit
A
0 30 0 45
U
0
20
10
0
C
B 10
300 450
0
10
0
B
0
20
0
30
10
0
A
0
10
10
10
0
(2)
Type 1 – female
(1)
H
Type 2 – female H
A U
B U
Type 3 – male
For dimensions of holes for connections, see p. 100
B
A
Dimension H changes with the rating and is specified on p. 112-117
Type 4 – male
U
U
Rear cable input Aluminium gland plate(s) for cable entry 170mm x 410mm Single bar : 1 plate Double bar : 2 plates
A B B A
Type 1 – male
Type 2 – female
Dimension H changes with the rating and is specified on p. 112-117 The dimensions refer to standard tees (bold = double bar) See p. 100 for dimensions of cover plate (1) and bars (2) Connection interfaces + vertical elbows – bespoke dimensions Please specify required dimensions when ordering Minimum and maximum dimensions of single bar Aluminium Copper (A) min. / max. (mm) (B) min. / max. (mm) (U) min. / max. (mm)
630 A to 2 000 A 800 A to 2 500 A 150 / 1 299 300 / 1 299 150 / 400
Minimum and maximum dimensions of double bar Aluminium Copper (A) min. / max. (mm) (B) min. / max. (mm) (U) min. / max. (mm)
Dimensions of the box Aluminium Copper (A) (mm) (B) (mm) (C) (mm)
630 A to 1 250 A 800 A to 1 250 A 320 600 610
1 600 A to 2 000 A 2 500 A to 4 000 A 1 600 A to 2 500 A 3 200 A to 5 000 A 320 600 600 600 810 810
2 500 A to 4 000 A 3 200 A to 5 000 A 300 / 1 449 450 / 1 449 150 / 400
All dimensions (mm) are nominal
99
SCP super compact busbar technical information n Connection interfaces Cover plate drilling details Aluminium 630 A to 2 000 A Copper 800 A to 2 500 A
Ă˜9
Ă˜9 15 75
75
100 100
125
100
605
100
15
75 100
100
75
100
100
15
15
15
15
100
430
75
100
125
555 15
100
15
100
75
100
100
100
15
15
Ă˜9
330
Aluminium 4 000 A Copper 5 000 A
Aluminium 2 500 A to 3 200 A Copper 3 200 A to 4 000 A
430
100
100
15
100
100
15
430
Bar drilling details
Aluminium 800 A-1 000 A Copper 1 000 A-1 250 A
Aluminium 630 A Copper 800 A
Aluminium 1 250 A
Aluminium 1 600 A
Copper 1 600-2 000 A
Holes 9 x 30
50
75
110
Aluminium 2 000 A
120
Copper 2 500 A
60
30
90
90
155
150
Aluminium 2 500 A Copper 3 200 A
Holes 9 x 30
50 50 50
90 150
205
120
60
30
30
30
50 50 50
120
60
120
60
Holes 15 x 20
70
150
200
Aluminium 4 000 A
Aluminium 3 200 A Copper 4 000 A
Copper 5 000 A
Holes 9 x 30
180
70
180
205
60
All dimensions (mm) are nominal
100
60 30
50 50 50 200
205
70
200
120
120
60 50 50 50
30
60 30
50 50 50
120
Holes 15 x 20
120
60
30
50
120
60
30
120
60
30
35
120
60
120
Holes 15 x 20
30
n Compatibility with Zucchini SCP busbar
417 V secondary voltage
The Zucchini SCP busbar trunking system and Legrand cast resin transformers have been designed in perfect synergy for a direct connection The versions shown below represent just a few of the standardised solutions 400 V secondary voltage Transformer kVA (kVA)
630 800 1 000 1 250 1 600 2 000 2 500
Busbar (aluminium)
Insulation class (kV)
400 V current (A)
IK 6 % (kA)
12, 17·5, 24, 36
910 1 155 1 444 1 805 2 310 2 887 3 609
15·20 19·30 24·10 30·10 38·50 48·20 60·20
Transformer kVA (kVA)
630 800 1 000 1 250 1 600 2 000 2 500 3 150
Family
SCP 1 000 A SCP 1 250 A SCP 1 600 A SCP 2 000 A SCP 2 500 A SCP 3 200 A SCP 4 000 A
Connection component
60281012P 60281014P 60281016P 60281017P 60391014P 60391016P 60391017P
Busbar (copper)
Insulation class (kV)
400 V current (A)
IK 6 % (kA)
Family
12, 17·5, 24, 36
910 1 155 1 444 1 805 2 310 2 887 3 609 4 547
15·20 19·30 24·10 30·10 38·50 48·20 60·20 65·001
SCP 1 000 A SCP 1 250 A SCP 1 600 A SCP 2 000 A SCP 2 500 A SCP 3 200 A SCP 4 000 A SCP 5 000 A
1 : 7% impedance
Connection component
65281011P 65281013P 65281015P 65281016P 65391018P 65391015P 65391016P 65391018P
Transformer
Busbar (aluminium)
Insulation class (kV)
417 V current (A)
IK 6 % (kA)
630 800 1 000 1 250 1 600 2 000 2 500
12, 17·5, 24, 36
873 1 108 1 385 1 731 2 216 2 770 3 462
14·60 18·50 23·10 28·90 37·00 46·20 57·70
kVA (kVA)
Insulation class (kV)
417 V current (A)
IK 6 % (kA)
Family
12, 17·5, 24, 36
873 1 108 1 385 1 731 2 216 2 770 3 462 4 362
14·60 18·50 23·10 28·90 37·00 46·20 57·70 62·401
SCP 1 000 A SCP 1 250 A SCP 1 600 A SCP 2 000 A SCP 2 500 A SCP 3 200 A SCP 4 000 A SCP 5 000 A
kVA (kVA)
Transformer
630 800 1 000 1 250 1 600 2 000 2 500 3 150
SCP 1 000 A SCP 1 250 A SCP 1 600 A SCP 2 000 A SCP 2 500 A SCP 3 200 A SCP 4 000 A
Connection component
60281012P 60281014P 60281016P 60281017P 60391014P 60391016P 60391017P
Busbar (copper) Connection component
65281011P 65281013P 65281015P 65281016P 65391018P 65391015P 65391016P 65391018P
433 V secondary voltage Transformer
Busbar (aluminium)
Insulation class (kV)
433 V current (A)
IK 6 % (kA)
630 800 1 000 1 250 1 600 2 000 2 500
12, 17·5, 24, 36
841 1 067 1 334 1 667 2 134 2 667 3 334
14·10 17·80 22·30 27·80 35·60 44·50 55·60
kVA (kVA)
Insulation class (kV)
433 V current (A)
IK 6 % (kA)
Family
12, 17·5, 24, 36
841 1 067 1 334 1 667 2 134 2 667 3 334 4 201
14·10 17·80 22·30 27·80 35·60 44·50 55·60 60·101
SCP 1 000 A SCP 1 250 A SCP 1 600 A SCP 2 000 A SCP 2 500 A SCP 3 200 A SCP 4 000 A SCP 5 000 A
kVA (kVA)
Transformer
Transformer to busbar connection
Family
630 800 1 000 1 250 1 600 2 000 2 500 3 150
Family
SCP 1 000 A SCP 1 250 A SCP 1 600 A SCP 2 000 A SCP 2 500 A SCP 3 200 A SCP 4 000 A
Connection component
60281012P 60281014P 60281016P 60281017P 60391014P 60391016P 60391017P
Busbar (copper) Connection component
65281011P 65281013P 65281015P 65281016P 65391018P 65391015P 65391016P 65391018P
101
SCP super compact busbar technical information n Tap-off boxes
63 A to 630 A : plug-in type
Empty tap-off box 63 A to 630 A
Polyester coated, galvanised steel structure. Metal boxes are suitable for heavy loads and are used to shield electromagnetic fields caused by flows of current Fuses not included. Please contact us on +44 (0) 370 608 9020 for details of available fuses
From 63 A to 160 A
With fuse carrier From 63 A to 160 A
Cover with AC21A disconnection Connection terminals for cables max 50 mm2
757
n Tap-off boxes
24
4
0
24 4
0
57
Aluminium cable entry plates on both sides
183
Cover with AC21A disconnection
757
183
57
From 250 A to 630 A
Cover with AC21A disconnection
With switch disconnector From 250 A to 630 A
1034
Side cable input
41
0
5
Cover with AC21A disconnection
1 034
286
78
41
5
0 78
286
Aluminium cable entry plates on both sides
Tap-off boxes can be pre-equipped with DPX MCCBs on request, contact us on +44 (0) 370 608 9020 Can be installed and removed when the busbar is energized To be used with components with any rating, with tap-off outlets
Side cable input
These tap-off boxes are equipped with a switch disconnector (AC23) and a fuse carrier. The disconnector switch is operated through a rotary handle on the cover (not shown in the picture) N.B. Cover with AC21A disconnection : it is not possible to open, close, install or pull out the tap-off box if the switch is in ‘ON’ position Can be installed and removed when the busbar is energized To be used with components with any rating, with tap-off outlets Fuses not included. Please contact us on +44 (0) 370 608 9020 for details of available fuses
All dimensions (mm) are nominal
102
n Tap-off boxes
n Bolt-on tap-off boxes
With AC23A switch disconnector and fuse carrier, 125 A to 400 A : plug-in type
With AC23 switch disconnector and fuse carrier : 125 A to 1 250 A
Rear cable input 34
0
320
260
C
E
550
A
B
85
0
54
D
20
Can be installed and removed when the busbar is energized because the protective earth makes contact before other conductors To be applied on components with any rating, with tap-off outlets For operating voltages (Ue) different from 400 V, please contact us on +44 (0) 370 608 9020 Fuses not included. Please contact us on +44 (0) 370 608 9020 for details of available fuses Specification Rated insulating AC voltage Rated impulse withstand voltage Type of rated duty Rated conditional short circuit current
Ui (V) Uimp (kV) (kA)
1000 12 AC23A 100 IEC 60947-3
Please specify SCP type when ordering Boxes cannot be installed simultaneously on both sides of the same junction
The bolted boxes are to be installed directly on the junction when the busbar is disconnected and not energized For operating voltages (Ue) different from 400 V please contact us on +44 (0) 370 608 9020 Fuses not included. Please contact us on +44 (0) 370 608 9020 for details of available fuses Dimensions of the box Box rating (A) (mm) (B) (mm) (C) (mm) (D) (mm) (E) (mm)
125 A to 400 A 365 630 270 95 635
630 A 400 750 280 115 680
800 A to 1 250 A 450 1 050 300 115 750
Specification Rated insulating AC voltage Rated impulse withstand voltage Type of rated duty Rated conditional short circuit current
Ui (V) Uimp (kV) (kA)
1 000 12 AC23A 100 IEC 60947-3
All dimensions (mm) are nominal
103
SCP super compact busbar technical information n Fixing supports Suspension bracket for edgeways installation
) 00 2 0 3 000 x. a m
(
15
110
A
M10
40
Slot 9x20 190
Suspension bracket for edgeways installation Single bar Aluminium busbar rating (A) Dimension A (mm)
630 210
800 210
1 000 210
Copper busbar rating (A) Dimension A (mm)
630 –
800 210
1 000 210
1 250 210
Double bar 1 600 250
2 000 300
2 500 460
3 200 520
1 600 250
2 000 250
2 500 300
3 200 460
Single bar 1 250 210
4 000 560
5 000 –
Double bar 4 000 520
5 000 560
Suspension bracket for flat installation Flat length ) 00 2 0 3 000 x.
a (m
100 15
100
40
Slot 9x20
210
130
M10
A
Suspension bracket for flat installation Single bar Aluminium busbar rating (A) Dimension A (mm)
630 190
800 190
1 000 190
Copper busbar rating (A) Dimension A (mm)
630 –
800 190
1 000 190
1 250 190
Double bar 1 600 315
2 000 315
2 500 430
3 200 490
1 600 315
2 000 315
2 500 315
3 200 430
Single bar 1 250 190
4 000 530 Double bar
All dimensions (mm) are nominal
104
5 000 –
4 000 490
5 000 530
n Fixing supports
Type A and B brackets are used for wall installation, while type C and D are used for floor installation
Type A With bracket and spring
Type C With springs
Type B Standard with anti-seismic bracket1
Type D Bracket only
Type E Naval applications
1 : For single bar lengths, the standard bracket is also anti-seismic rated For double bar loads there are two separate Cat. Nos. see p. 82
Fixing supports for vertical lengths – dimensions 30
Version 3
x
Y
30 x
84
1
4
17
Ø9 84
70
50
Ø9
50
Version 1
131
131
Y
0
17
4
46
0
0
375
5
160
21
26
140
240
160
17
4
21
Slot 9 x 30 Slot 9 x 30
Version 2 30
Version 4
0 x
Ø9
4
17
Y
84
50
17
x
Y
30 Y
131
131
50
X
Y
84
Ø9
0
375
30
0
7
21
160
140
240
160
17
4
17
56
0
4
21
Slot 9 x 30
Slot 9 x 30
X and Y dimensions of the brackets Version 1 Version 1
Version 2
Version 2
Version 3 Version 4 Version 4
Aluminium 630 A to 1 000 A Copper 800 A to 1 250 A x (mm) 90 y (mm) -
1 600 A 2 000 A 80 -
2 000 A 2 500 A 90 -
2 500 A 3 200 A 80 110
1 250 A 1 600 A 120 -
3 200 A 4 000 A 80 80
4 000 A 5 000 A 80 90
All dimensions (mm) are nominal
105
SCP super compact busbar technical information n Fixing in standard conditions For vertical path sections of less than 2 m the use of standard suspension brackets is sufficient Horizontal installation fixing Fixing recommended : 1 bracket every 1·5 m Edgeways length
Flat length
Vertical installation fixing (rising mains) In the case of rising mains, in addition to the standard brackets, it will also be necessary to use other screw fixed brackets to prevent the busbar sliding Due to their pre-loaded springs, the brackets absorb the forces pressing on the busbar and direct any expansion in a precise direction They therefore operate as a limitation, and support the traction and compression forces of the busbar trunking system • Section between 2 and 4 m In the lowest point Type B vertical bracket if secured to the wall, or Type D if secured to the floor and one edgeways installation bracket • Section of over 4 m In the lowest point Type A vertical bracket if secured to the wall, or Type C if secured to the floor and one edgeways installation bracket every 1·5 m of the path and one Type A or C bracket based on the following table Aluminium
Copper
Rating (A)
(m)
Rating (A)
(m)
630 800 1 000 1 250 1 600 2 000 2 500 3 200 4 000 –
17 16 16 15 12 10 14 12 10 –
– 800 1 000 1 250 1 600 2 000 2 500 3 200 4 000 5 000
– 10 9 9 7 6 4 7 6 5
n Fixing for installation in seismic environments Vertical installation (section lengths > 2 m) Fit 1 bracket every 1·5 m of the busbar Every 2 anti-seismic brackets with bracket (Type B) use one bracket with bracket and spring (Type A) Edgeways length
All dimensions (mm) are nominal
106
n Protective bellows
Covering accessory to be used for outdoor installations and wherever the standard IP 55 protection is not adequate For more information, please contact us on +44 (0) 370 608 9020
Recommended for protection of the interface connection on panel boards, dry-type transformers with enclosure and oil-type transformers For Legrand cast resin transformers, custom-made connections are available upon request (see p. 83)
150
215
540 150 135
600 (A)
150
135
Single bar Cat. No. SF766040
700 760 (B)
145
150
150
150
150
145
15
15
650
710 (A)
150
190
Double bar Cat. No. SF927140
150
Flat length
150
190
Edgeways length
215
15
15
B
A
400
n Protective cover for outdoor applications
860 920 (B)
Single bar
Double bar
Aluminium
630 A to 2 000 A Cat. No. SF766040
2 500 A to 4 000 A Cat. No. SF927140
Copper
800 A to 2 500 A Cat. No. SF766040
3 200 A to 5 000 A Cat. No. SF927140
All dimensions (mm) are nominal
107
SCP super compact busbar technical information n Flexible braid connections
n The system : the Legrand transformer advantage
When ordering, please specify hole dimensions on transformer side (A, B, Ă˜ D) and length L
The Legrand Group offer meets the needs of any installation. Legrand cast resin transformers have specifically designed connections for Zucchini busbars The versions shown represent some of the standardised solutions
Holes on busbar side see p. 100 L
For the outgoing busbar run from the transformer, see p. 98-100 Type A setup
B
Holes on transformer side to be specified
Lv side Ă˜D
Type B setup A
Example of a vertical connection
Lv side The distance between the phases can be designed according to your needs
Transformer
Type C setup
Lv side
ATR connection interface
Cast resin transformer
A technical drawing of the transformer is needed when creating an ATR connection interface For Legrand cast resin transformers contact us on +44 (0) 370 608 9020
All dimensions (mm) are nominal
108
SCP super compact busbar installation guidelines n Installation design 1 Use a right hand end feed unit (without monobloc) To position the tap-off boxes correctly, the neutral conductor of the riser mains must be on the left side of the length
1 N L
L2
L3
7
2 Use one or more suspension brackets for the vertical lengths, according to the weight of the whole riser mains For risers that are shorter than 4 m, fix to the base with type B brackets (see p. 81) When longer, use a type A suspension bracket (see p. 81) every 300 kg of riser (including boxes)
3
3 Use a standard suspension bracket to hang the busbar every 2 metres of riser mains 4 Use lengths with tap-off outlets (see p. 66)
5
5 Use S120 fire barrier kit for each compartment floor (see p. 69) 6 Tap-off boxes can be installed in the tap-off outlets and near the connection between lengths In both cases, the boxes extend downward 7 Position the IP 55 end cover at the end of the riser mains 4
6
For further information, please contact us on +44 (0) 370 608 9020
N
N
2
N
N
1
109
SCP super compact busbar installation guidelines n Minimum distance of the wall / ceiling lengths
300
100
Ceiling 100
Ceiling
Wall 100
Wall
Wall 300
When there are tap-off units along the busbars, the minimum distances depend on the dimensions of the tap-offs selected. Ceiling 300
Wall
300
300
*
Wall
*
When there is a tap-off box installed above the busbar, check the overall dimension of the open cover of the tap-off unit used (see p. 47-48)
100
300
Ceiling
Wall 100
80
Wall
80
Minimum installation distance when there are several adjacent lines
100
100
300
Ceiling
Wall
60
Wall
Minimum installation distance when there are several overlapped lines
For further information, please contact us on +44 (0) 370 608 9020
All dimensions (mm) are nominal
110
n Installation sequence of the junction
Measurement of trunking lengths
1 Installation instructions are included near the junction (Fig.1) Make sure that the contacts are clean before joining lengths Fig. 1
The exact length to be ordered can be determined by measuring the distance between the components (as shown below) and then subtracting 270 mm Length = Q - 270 mm Example : dimension measured = 2 500 mm length required = 2 230 mm
30 mm Instructions
nQ
sio
en
dim
2 Make sure that the earth plate of the trunking length is inserted behind the front plate of the junction monobloc (Fig.2)
N
12
3
The positioning pin on the monobloc should be fitted into the corresponding slot on the earth plate. Verify the distance between lengths, 270 mm, before tightening the monobloc completely (Fig.3) Fig. 2 m
0m
27
Fig. 3
n Measurement of bespoke components Horizontal elbow
3 Tighten the bolt of the monobloc until the 1st head breaks off (Fig. 4) The bolt that tightens the monobloc has a second head which is used when carrying out operations or inspections on the line
The exact length to be ordered can be determined by measuring the dimensions Q1 and Q2 (as shown below) and then subtracting 70 mm from each dimension A = Q1 - 70 mm B = Q2 - 70 mm
The nominal tightening torque is 85Nm
For further information, please contact us on +44 (0) 370 608 9020
Fig. 4
85Nm
4 Install the junction covers (Fig. 5) Completed IP 55 installation (Fig. 6)
A = Q1 - 70 mm
B = Q2 - 70 mm
Q1
For further information, please contact us on +44 (0) 370 608 9020
Q2
Fig. 5
Fig. 6
All dimensions (mm) are nominal
111
SCP super compact busbar – 4 conductor (aluminium) technical data n 3L + N + PE aluminium
H
130
N L1 L2 L3 PE
Aluminium
Single bar
Rated current Casing overall dimensions Operating voltage Insulation voltage Frequency Rated short-time current for three-phase fault (1 s) Allowable peak current for three-phase fault Rated short-time current for single-phase fault (1 s) Allowable peak current for single-phase fault Allowable specific energy for three-phase fault Phase resistance Phase reactance (50 Hz) Phase impedance Phase resistance at thermal conditions Phase impedance at thermal conditions Neutral resistance Resistance of the protective conductor (PE 1) Resistance of the protective conductor (PE 2) Resistance of the protective conductor (PE 3) Reactance of the protective conductor (50 Hz) Resistance of the fault loop (PE 1) Resistance of the fault loop (PE 2) Resistance of the fault loop (PE 3) Reactance of the fault loop (50 Hz) Impedance of the fault loop (PE 1) Impedance of the fault loop (PE 2) Impedance of the fault loop (PE 3) Zero-sequence resistance phase - N Zero-sequence reactance phase - N Zero-sequence Impedance phase - N Zero-sequence resistance phase - PE Zero-sequence reactance phase - PE Zero-sequence Impedance phase - PE
Voltage drop factor with distributed load ∆V = k.L.Ie.10-6 [V]
k [V/m/A]10-6
Weight (PE 1) Weight (PE 2) Weight (PE 3) Fire load Degree of protection Thermal resistance class of the insulating materials Joule effect losses at rated current Min./max. ambient temperature
In [A] 630 L x H [mm] 130 x 130 Ue [V] 1 000 Ui [V] 1 000 f [Hz] 50/60 Icw [kA]rms 36 Ipk [kA] 76 Icw [kA]rms 22 Ipk [kA] 48 I2t [MA2s] 1 296 R20 [mΩ/m] 0·077 X [mΩ/m] 0·023 Z [mΩ/m] 0·080 Rt [mΩ/m] 0·084 Z [mΩ/m] 0·087 R20 [mΩ/m] 0·077 RPE [mΩ/m] 0·125 RPE [mΩ/m] 0·036 RPE [mΩ/m] 0·050 XPE [mΩ/m] 0·080 Ro [mΩ/m] 0·209 Ro [mΩ/m] 0·120 Ro [mΩ/m] 0·134 Xo [mΩ/m] 0·10 Zo [mΩ/m] 0·233 Zo [mΩ/m] 0·158 Zo [mΩ/m] 0·169 Ro [mΩ/m] 0·306 Xo [mΩ/m] 0·174 Zo [mΩ/m] 0·352 Ro [mΩ/m] 0·581 Xo [mΩ/m] 0·263 Zo [mΩ/m] 0·638 cosϕ = 0·70 65·3 cosϕ = 0·75 67·9 cosϕ = 0·80 70·3 cosϕ = 0·85 72·5 cosϕ = 0·90 74·3 cosϕ = 0·95 75·5 cosϕ = 1·00 72·9 p [kg/m] 17·3 p [kg/m] 20·8 p [kg/m] 18·4 [kWh/m] 4·5 IP 55 – B/F1 P [W/m] 100 [°C] -5/50
800 1 000 1 250 130 x 130 130 x 130 130 x 130 1 000 1 000 1 000 1 000 1 000 1 000 50/60 50/60 50/60 42 50 75 88 110 165 25 30 45 55 66 99 1 764 2 500 5 625 0·057 0·057 0·046 0·017 0·017 0·015 0·059 0·059 0·048 0·063 0·068 0·055 0·066 0·070 0·057 0·057 0·057 0·046 0·125 0·125 0·125 0·036 0·036 0·036 0·050 0·050 0·050 0·078 0·078 0·048 0·188 0·193 0·180 0·099 0·104 0·091 0·113 0·118 0·105 0·10 0·10 0·06 0·211 0·215 0·191 0·137 0·141 0·111 0·148 0·152 0·123 0·257 0·257 0·238 0·160 0·160 0·128 0·303 0·303 0·270 0·519 0·519 0·369 0·229 0·229 0·191 0·567 0·567 0·416 48·9 51·9 42·9 50·9 54·1 44·6 52·7 56·1 46·2 54·4 58·0 47·7 55·8 59·6 48·9 56·7 60·8 49·7 54·9 59·1 48·0 17·0 17·0 18·7 20·5 20·5 23·2 18·1 18·1 20·8 5·5 5·5 6·0 55 55 55 B/F1 B/F1 B/F1 122 205 260 -5/50 -5/50 -5/50
Double bar 1 600 130 x 170 1 000 1 000 50/60 80 176 48 106 6 400 0·033 0·014 0·036 0·039 0·041 0·033 0·113 0·028 0·041 0·039 0·152 0·067 0·080 0·05 0·161 0·085 0·096 0·172 0·106 0·202 0·321 0·175 0·366 32·3 33·4 34·3 35·1 35·7 35·9 33·8 20·3 24·9 21·8 8·5 55 B/F1 300 -5/50
2 000 130 x 220 1 000 1 000 50/60 80 176 48 106 6 400 0·025 0·011 0·027 0·030 0·032 0·025 0·101 0·023 0·033 0·028 0·131 0·053 0·063 0·04 0·137 0·066 0·074 0·140 0·108 0·177 0·270 0·212 0·343 25·1 25·9 26·7 27·3 27·7 27·8 26·2 30·7 36·7 32·6 10·5 55 B/F1 363 -5/50
2 500 130 x 380 1 000 1 000 50/60 150 330 90 198 22 500 0·021 0·006 0·022 0·024 0·025 0·021 0·075 0·014 0·021 0·020 0·099 0·038 0·045 0·03 0·103 0·046 0·052 0·107 0·083 0·135 0·217 0·155 0·267 18·4 19·2 19·9 20·6 21·2 21·6 21·0 43·7 53·9 46·9 16·0 55 B/F1 455 -5/50
3 200 4 000 130 x 440 130 x 480 1 000 1 000 1 000 1 000 50/60 50/60 160 160 352 352 96 96 211 211 25 600 25 600 0·016 0·013 0·006 0·006 0·017 0·014 0·019 0·016 0·020 0·018 0·016 0·013 0·069 0·065 0·012 0·011 0·018 0·017 0·015 0·016 0·088 0·081 0·031 0·027 0·037 0·033 0·02 0·02 0·091 0·084 0·038 0·035 0·043 0·040 0·080 0·070 0·073 0·060 0·108 0·092 0·196 0·164 0·148 0·146 0·246 0·22 15·4 13·7 16·0 14·1 16·5 14·5 16·9 14·9 17·3 15·1 17·5 15·2 16·7 14·3 52·3 62·7 64·3 75·7 56·1 66·8 19·0 21·0 55 55 B/F1 B/F1 592 790 -5/50 -5/50
Regulations and conformity : 1 : Class F thermal resistance (155°C) available on request IEC 61439-6 (BS EN 61439-6) +44 (0) 370 608 9020 Suitable for the following climates : In : rated current referred to a room temperature of 40°C Constant humid climate (IEC 60068 2 – 11) Cyclical humid climate (IEC 60068 2 – 30) Degree of protection : IP 55; IP x7 carrying lines available with accessories, on request - +44 (0) 370 608 9020 Insulation and surface treatment of the conductors : Insulated conductors for the whole length, aluminum copper-plated and tin-plated PE 1 PE 3 PE 2 Busbar casing material : Standard version Extra earth - aluminium Extra earth - copper 1·5 mm galvanised steel plate, pre-painted or stainless steel (available, if required, with special paint and/or with thickness 2 mm)
112
SCP super compact busbar – 4 conductor (copper) technical data
130
H
n 3L + N + PE copper
N L1 L2 L3 PE
Copper Rated current Casing overall dimensions Operating voltage Insulation voltage Frequency Rated short-time current for three-phase fault (1 s) Allowable peak current for three-phase fault Rated short-time current for single-phase fault (1 s) Allowable peak current for single-phase fault Allowable specific energy for three-phase fault Phase resistance Phase reactance (50 Hz) Phase impedance Phase resistance at thermal conditions Phase impedance at thermal conditions Neutral resistance Resistance of the protective conductor (PE 1) Resistance of the protective conductor (PE 2) Resistance of the protective conductor (PE 3) Reactance of the protective conductor (50 Hz) Resistance of the fault loop (PE 1) Resistance of the fault loop (PE 2) Resistance of the fault loop (PE 3) Reactance of the fault loop (50 Hz) Impedance of the fault loop (PE 1) Impedance of the fault loop (PE 2) Impedance of the fault loop (PE 3) Zero-sequence resistance phase - N Zero-sequence reactance phase - N Zero-sequence Impedance phase - N Zero-sequence resistance phase - PE Zero-sequence reactance phase - PE Zero-sequence Impedance phase - PE
In [A] 800 L x H [mm] 130 x 130 Ue [V] 1 000 Ui [V] 1 000 f [Hz] 50/60 Icw [kA]rms 45 Ipk [kA] 95 Icw [kA]rms 27 [kA] 57 I2t [MA2s] 2 025 R20 [mΩ/m] 0·039 X [mΩ/m] 0·023 Z [mΩ/m] 0·045 Rt [mΩ/m] 0·042 Z [mΩ/m] 0·048 R20 [mΩ/m] 0·039 RPE [mΩ/m] 0·125 RPE [mΩ/m] 0·036 RPE [mΩ/m] 0·050 XPE [mΩ/m] 0·054 Ro [mΩ/m] 0·167 Ro [mΩ/m] 0·078 Ro [mΩ/m] 0·092 Xo [mΩ/m] 0·077 Zo [mΩ/m] 0·184 Zo [mΩ/m] 0·110 Zo [mΩ/m] 0·120 Ro [mΩ/m] 0·170 Xo [mΩ/m] 0·159 Zo [mΩ/m] 0·233 Ro [mΩ/m] 0·507 Xo [mΩ/m] 0·201 Zo [mΩ/m] 0·545 cosϕ = 0·70 39·9 cosϕ = 0·75 40·7 cosϕ = 0·80 41·3 Voltage drop factor with distributed load k [V/m/A]10-6 cosϕ = 0·85 41·7 ∆V = k.L.Ie.10-6 [V] cosϕ = 0·90 41·7 cosϕ = 0·95 41·1 cosϕ = 1·00 36·7 Weight (PE 1) p [kg/m] 31·0 Weight (PE 2) p [kg/m] 35·0 Weight (PE 3) p [kg/m] 33·0 Fire load [kWh/m] 4·5 Degree of protection IP 55 Thermal resistance class of the insulating materials – B/F1 Joule effect losses at rated current P [W/m] 81 Min./max. ambient temperature [°C] -5/50
Single bar 1 000 1 250 1 600 130 x 130 130 x 130 130 x 170 1 000 1 000 1 000 1 000 1 000 1 000 50/60 50/60 50/60 50 60 85 110 132 187 30 36 51 66 79 112 2 500 3 600 7 225 0·030 0·030 0·022 0·017 0·017 0·015 0·035 0·035 0·027 0·035 0·037 0·027 0·039 0·041 0·031 0·030 0·030 0·022 0·125 0·125 0·113 0·036 0·036 0·028 0·050 0·050 0·041 0·054 0·054 0·044 0·160 0·162 0·140 0·071 0·073 0·055 0·085 0·087 0·068 0·071 0·071 0·059 0·175 0·177 0·152 0·100 0·102 0·081 0·110 0·112 0·090 0·155 0·155 0·115 0·151 0·151 0·114 0·216 0·216 0·162 0·429 0·429 0·331 0·177 0·177 0·143 0·464 0·464 0·361 31·5 33·0 25·6 32·2 33·9 26·1 32·8 34·6 26·5 33·3 35·1 26·7 33·4 35·4 26·7 33·1 35·1 26·2 30·0 32·2 23·3 31·0 31·0 42·0 35·0 35·0 47·0 32·0 32·0 44·0 5·5 5·5 8 55 55 55 B/F1 B/F1 B/F1 104 174 207 -5/50 -5/50 -5/50
Double bar 2 000 130 x 170 1000 1000 50/60 88 194 53 116 7 744 0·018 0·014 0·023 0·022 0·026 0·018 0·113 0·028 0·041 0·044 0·135 0·050 0·063 0·058 0·147 0·077 0·086 0·120 0·098 0·155 0·283 0·150 0·320 22·1 22·4 22·6 22·7 22·5 22·0 19·1 46·0 51·0 48·0 8·2 55 B/F1 265 -5/50
2 500 130 x 220 1 000 1 000 50/60 88 194 53 116 7 744 0·014 0·011 0·018 0·017 0·020 0·014 0·101 0·023 0·033 0·032 0·118 0·040 0·050 0·043 0·126 0·059 0·066 0·098 0·065 0·118 0·221 0·124 0·253 17·1 17·4 17·5 17·5 17·4 17·0 14·7 69·0 70·0 66·0 10·5 55 B/F1 319 -5/50
3 200 130 x 380 1 000 1 000 50/60 170 374 102 224 28 900 0·011 0·007 0·013 0·013 0·015 0·011 0·075 0·014 0·021 0·022 0·088 0·027 0·034 0·029 0·093 0·040 0·045 0·083 0·056 0·100 0·177 0·111 0·209 12·2 12·4 12·6 12·8 12·8 12·6 11·2 84·0 94·0 87·0 16 55 B/F1 399 -5/50
4 000 5 000 130 x 440 130 x 480 1 000 1 000 1 000 1 000 50/60 50/60 176 176 387 387 106 106 232 232 30 976 30 976 0·009 0·007 0·006 0·006 0·011 0·009 0·011 0·008 0·013 0·010 0·009 0·007 0·069 0·065 0·012 0·011 0·018 0·017 0·017 0·016 0·080 0·073 0·023 0·019 0·029 0·025 0·023 0·022 0·083 0·077 0·033 0·029 0·037 0·034 0·071 0·062 0·055 0·042 0·090 0·075 0·178 0·144 0·094 0·086 0·201 0·168 10·5 8·9 10·8 8·9 10·9 9·0 11·0 9·0 11·0 8·9 10·9 8·6 9·8 7·3 101·0 126·0 114·0 139·0 105·0 130·0 19 21 55 55 B/F1 B/F1 541 636 -5/50 -5/50
Regulations and conformity : 1 : Class F thermal resistance (155°C) available on request IEC 61439-6 (BS EN 61439-6) +44 (0) 370 608 9020 Suitable for the following climates : In : rated current referred to a room temperature of 40°C Constant humid climate (IEC 60068 2 – 11) Cyclical humid climate (IEC 60068 2 – 30) Degree of protection : IP 55; IP x7 carrying lines available with accessories, on request - +44 (0) 370 608 9020 Insulation and surface treatment of the conductors : Insulated conductors for the whole length, aluminum copper-plated and tin-plated PE 1 PE 3 PE 2 Busbar casing material : Standard version Extra earth - aluminium Extra earth - copper 1·5 mm galvanised steel plate, pre-painted or stainless steel (available, if required, with special paint and/or with thickness 2 mm)
113
SCP super compact busbar – 5 conductor (aluminium) technical data
140
H
n SCP technical data functional earth clean earth / low noise SCP5C (3L + N + PE + FE) aluminium
FE N L1 L2 L3 PE
Aluminium
Single bar
Rated current Casing overall dimensions Operating voltage Insulation voltage Frequency Rated short-time current for three-phase fault (1 s) Allowable peak current for three-phase fault Rated short-time current for single-phase fault (1 s) Allowable peak current for single-phase fault Allowable specific energy for three-phase fault Phase resistance Phase reactance (50 Hz) Phase impedance Phase resistance at thermal conditions Phase impedance at thermal conditions Neutral resistance Functional earthing resistance (FE) Functional earthing reactance (FE) Resistance of the protective conductor (PE type 1) Resistance of the protective conductor (PE type 2) Resistance of the protective conductor (PE type 3) Reactance of the protective conductor (50 Hz) Resistance of the fault loop (PE 1) Resistance of the fault loop (PE 2) Resistance of the fault loop (PE 3) Reactance of the fault loop (50 Hz) Impedance of the fault loop (PE 1) Impedance of the fault loop (PE 2) Impedance of the fault loop (PE 3) Zero-sequence resistance phase - N Zero-sequence reactance phase - N Zero-sequence Impedance phase - N Zero-sequence resistance phase - PE Zero-sequence reactance phase - PE Zero-sequence Impedance phase - PE
Voltage drop factor with distributed load ∆V = k.L.Ie.10-6 [V]
k [V/m/A]10-6
Weight (PE 1) Weight (PE 2) Weight (PE 3) Fire load Degree of protection Thermal resistance class of the insulating materials Joule effect losses at rated current Min./max. ambient temperature
In [A] 630 L x H [mm] 140 x 130 Ue [V] 1 000 Ui [V] 1 000 f [Hz] 50/60 ICW [kA]rms 36 Ipk [kA] 76 ICW [kA]rms 22 Ipk [kA] 48 I2t [MA2s] 1 296 R20 [mΩ/m] 0·077 X [mΩ/m] 0·023 Z [mΩ/m] 0·080 Rt [mΩ/m] 0·084 Z [mΩ/m] 0·087 R20 [mΩ/m] 0·077 R20 [mΩ/m] 0·077 X [mΩ/m] 0·023 RPE [mΩ/m] 0·121 RPE [mΩ/m] 0·035 RPE [mΩ/m] 0·050 XPE [mΩ/m] 0·080 Ro [mΩ/m] 0·131 Ro [mΩ/m] 0·108 Ro [mΩ/m] 0·115 Xo [mΩ/m] 0·10 Zo [mΩ/m] 0·167 Zo [mΩ/m] 0·149 Zo [mΩ/m] 0·154 Ro [mΩ/m] 0·306 Xo [mΩ/m] 0·174 Zo [mΩ/m] 0·352 Ro [mΩ/m] 0·468 Xo [mΩ/m] 0·263 Zo [mΩ/m] 0·537 cosϕ = 0·70 65·3 cosϕ = 0·75 67·9 cosϕ = 0·80 70·3 cosϕ = 0·85 72·5 cosϕ = 0·90 74·3 cosϕ = 0·95 75·5 cosϕ = 1·00 72·9 p [kg/m] 21·6 p [kg/m] 23·0 p [kg/m] 20·6 [kWh/m] 5·6 IP 55 – B/F1 P [W/m] 100 [°C] -5/50
800 1 000 1 250 140 x 130 140 x 130 140 x 130 1 000 1 000 1 000 1 000 1 000 1 000 50/60 50/60 50/60 42 50 75 88 110 165 25 30 45 55 66 99 1 764 2 500 5 625 0·057 0·057 0·046 0·017 0·017 0·015 0·059 0·059 0·048 0·063 0·068 0·055 0·066 0·070 0·057 0·057 0·057 0·046 0·057 0·057 0·046 0·017 0·017 0·015 0·121 0·121 0·121 0·035 0·035 0·035 0·050 0·050 0·050 0·078 0·078 0·048 0·102 0·107 0·089 0·085 0·090 0·075 0·090 0·095 0·079 0·10 0·10 0·06 0·139 0·143 0·109 0·128 0·131 0·098 0·131 0·134 0·101 0·257 0·257 0·238 0·160 0·160 0·128 0·303 0·303 0·270 0·387 0·387 0·246 0·229 0·229 0·191 0·450 0·450 0·311 48·9 51·9 42·9 50·9 54·1 44·6 52·7 56·1 46·2 54·4 58·0 47·7 55·8 59·6 48·9 56·7 60·8 49·7 54·9 59·1 48·0 21·3 21·3 23·4 22·8 22·8 26·4 20·4 20·4 24·0 6·9 6·9 7·5 55 55 55 B/F1 B/F1 B/F1 122 205 260 -5/50 -5/50 -5/50
Double bar 1 600 140 x 170 1 000 1 000 50/60 80 176 48 106 6 400 0·033 0·014 0·036 0·039 0·041 0·033 0·033 0·014 0·110 0·028 0·040 0·039 0·064 0·054 0·057 0·05 0·083 0·076 0·078 0·172 0·106 0·202 0·213 0·175 0·276 32·3 33·4 34·3 35·1 35·7 35·9 33·8 25·4 28·6 25·5 10·6 55 B/F1 300 -5/50
2 000 140 x 220 1 000 1 000 50/60 80 176 48 106 6 400 0·025 0·011 0·027 0·030 0·032 0·025 0·025 0·011 0·098 0·023 0·033 0·028 0·050 0·042 0·044 0·04 0·064 0·057 0·059 0·140 0·108 0·177 0·173 0·212 0·274 25·1 25·9 26·7 27·3 27·7 27·8 26·2 38·4 41·4 37·4 13·1 55 B/F1 363 -5/50
2 500 140 x 380 1 000 1 000 50/60 150 330 90 198 22 500 0·021 0·006 0·022 0·024 0·025 0·021 0·021 0·006 0·074 0·014 0·020 0·020 0·041 0·033 0·034 0·03 0·048 0·042 0·043 0·107 0·083 0·135 0·113 0·155 0·192 18·4 19·2 19·9 20·6 21·2 21·6 21·0 54·6 60·1 53·1 20·0 55 B/F1 455 -5/50
3 200 4 000 140 x 440 140 x 480 1 000 1 000 1 000 1 000 50/60 50/60 160 160 352 352 96 96 211 211 25 600 25 600 0·016 0·013 0·006 0·006 0·017 0·014 0·019 0·016 0·020 0·018 0·016 0·013 0·016 0·013 0·006 0·006 0·068 0·064 0·012 0·011 0·018 0·017 0·015 0·016 0·032 0·027 0·026 0·022 0·028 0·024 0·02 0·02 0·038 0·035 0·034 0·031 0·035 0·032 0·080 0·070 0·073 0·060 0·108 0·092 0·107 0·070 0·148 0·146 0·183 0·162 15·4 13·7 16·0 14·1 16·5 14·5 16·9 14·9 17·3 15·1 17·5 15·2 16·7 14·3 65·4 78·4 72·1 84·9 64·0 76·0 23·8 26·3 55 55 B/F1 B/F1 592 790 -5/50 -5/50
Regulations and conformity : 1 : Class F thermal resistance (155°C) available on request IEC 61439-6 (BS EN 61439-6) +44 (0) 370 608 9020 Suitable for the following climates : In : rated current referred to a room temperature of 40°C Constant humid climate (IEC 60068 2 – 11) Cyclical humid climate (IEC 60068 2 – 30) Degree of protection : IP 55; IP x7 carrying lines available with accessories, on request - +44 (0) 370 608 9020 Insulation and surface treatment of the conductors : Insulated conductors for the whole length, aluminum copper-plated and tin-plated PE 1 PE 3 PE 2 Busbar casing material : Standard version Extra earth - aluminium Extra earth - copper 1·5 mm galvanised steel plate, pre-painted or stainless steel (available, if required, with special paint and/or with thickness 2 mm)
114
SCP super compact busbar – 5 conductor (copper) technical data
140
H
n SCP technical data functional earth clean earth / low noise SCP5C (3L + N + PE + FE) copper
FE N L1 L2 L3 PE
Copper
Single bar
Rated current Casing overall dimensions Operating voltage Insulation voltage Frequency Rated short-time current for three-phase fault (1 s) Allowable peak current for three-phase fault Rated short-time current for single-phase fault (1 s) Allowable peak current for single-phase fault Allowable specific energy for three-phase fault Phase resistance Phase reactance (50 Hz) Phase impedance Phase resistance at thermal conditions Phase impedance at thermal conditions Neutral resistance Functional earthing resistance (FE) Functional earthing reactance (FE) Resistance of the protective conductor (PE type 1) Resistance of the protective conductor (PE type 2) Resistance of the protective conductor (PE type 3) Reactance of the protective conductor (50 Hz) Resistance of the fault loop (PE 1) Resistance of the fault loop (PE 2) Resistance of the fault loop (PE 3) Reactance of the fault loop (50 Hz) Impedance of the fault loop (PE 1) Impedance of the fault loop (PE 2) Impedance of the fault loop (PE 3) Zero-sequence resistance phase - N Zero-sequence reactance phase - N Zero-sequence Impedance phase - N Zero-sequence resistance phase - PE Zero-sequence reactance phase - PE Zero-sequence Impedance phase - PE
Voltage drop factor with distributed load ∆V = k.L.Ie.10-6 [V]
k [V/m/A]10-6
Weight (PE 1) Weight (PE 2) Weight (PE 3) Fire load Degree of protection Thermal resistance class of the insulating materials Joule effect losses at rated current Min./max. ambient temperature
In [A] 800 L x H [mm] 140 x 130 Ue [V] 1 000 Ui [V] 1 000 f [Hz] 50/60 Icw [kA]rms 45 Ipk [kA] 95 Icw [kA]rms 27 Ipk [kA] 57 I2t [MA2s] 2025 R20 [mΩ/m] 0·039 X [mΩ/m] 0·023 Z [mΩ/m] 0·045 Rt [mΩ/m] 0·042 Z [mΩ/m] 0·048 R20 [mΩ/m] 0·039 R20 [mΩ/m] 0·039 X [mΩ/m] 0·023 RPE [mΩ/m] 0·125 RPE [mΩ/m] 0·036 RPE [mΩ/m] 0·050 XPE [mΩ/m] 0·054 Ro [mΩ/m] 0·072 Ro [mΩ/m] 0·061 Ro [mΩ/m] 0·064 Xo [mΩ/m] 0·077 Zo [mΩ/m] 0·105 Zo [mΩ/m] 0·098 Zo [mΩ/m] 0·100 Ro [mΩ/m] 0·170 Xo [mΩ/m] 0·159 Zo [mΩ/m] 0·233 Ro [mΩ/m] 0·408 Xo [mΩ/m] 0·196 Zo [mΩ/m] 0·453 cosϕ = 0·70 39·9 cosϕ = 0·75 40·7 cosϕ = 0·80 41·3 cosϕ = 0·85 41·7 cosϕ = 0·90 41·7 cosϕ = 0·95 41·1 cosϕ = 1·00 36·7 p [kg/m] 39·0 p [kg/m] 41·0 p [kg/m] 38·0 [kWh/m] 5·6 IP 55 – B/F1 P [W/m] 81 [°C] -5/50
1 000 1 250 1 600 140 x 130 140 x 130 140 x 170 1 000 1 000 1 000 1 000 1 000 1 000 50/60 50/60 50/60 50 60 85 110 132 187 30 36 51 66 79 112 2 500 3 600 7 225 0·030 0·030 0·022 0·017 0·017 0·015 0·035 0·035 0·027 0·035 0·037 0·027 0·039 0·041 0·031 0·030 0·030 0·022 0·030 0·030 0·022 0·017 0·017 0·015 0·125 0·125 0·113 0·036 0·036 0·028 0·050 0·050 0·041 0·054 0·054 0·044 0·059 0·062 0·045 0·051 0·054 0·039 0·054 0·056 0·041 0·071 0·071 0·059 0·092 0·094 0·074 0·087 0·089 0·071 0·089 0·090 0·072 0·155 0·155 0·115 0·151 0·151 0·114 0·216 0·216 0·162 0·320 0·320 0·220 0·158 0·158 0·126 0·357 0·357 0·254 31·5 33·0 25·6 32·2 33·9 26·1 32·8 34·6 26·5 33·3 35·1 26·7 33·4 35·4 26·7 33·1 35·1 26·2 30·0 32·2 23·3 39·0 39·0 53·0 41·0 41·0 55·0 38·0 38·0 52·0 6·9 6·9 10·0 55 55 55 B/F1 B/F1 B/F1 104 174 207 -5/50 -5/50 -5/50
Double bar 2 000 140 x 170 1 000 1 000 50/60 88 194 53 116 7 744 0·018 0·014 0·023 0·022 0·026 0·018 0·018 0·014 0·113 0·028 0·041 0·044 0·038 0·033 0·035 0·058 0·069 0·067 0·068 0·120 0·098 0·155 0·188 0·135 0·231 22·1 22·4 22·6 22·7 22·5 22·0 19·1 58·0 60·0 57·0 10·3 55 B/F1 265 -5/50
2 500 140 x 220 1 000 1 000 50/60 88 194 53 116 7 744 0·014 0·011 0·018 0·017 0·020 0·014 0·014 0·011 0·101 0·023 0·033 0·032 0·029 0·026 0·027 0·043 0·052 0·050 0·051 0·098 0·065 0·118 0·142 0·136 0·197 17·1 17·4 17·5 17·5 17·4 17·0 14·7 86·0 83·0 79·0 13·1 55 B/F1 319 -5/50
3 200 140 x 380 1 000 1 000 50/60 170 374 102 224 28 900 0·011 0·007 0·013 0·013 0·015 0·011 0·011 0·007 0·075 0·014 0·021 0·022 0·023 0·019 0·020 0·029 0·037 0·035 0·035 0·083 0·056 0·100 0·092 0·104 0·139 12·2 12·4 12·6 12·8 12·8 12·6 11·2 105·0 111·0 104·0 20·0 55 B/F1 399 -5/50
4 000 5 000 140 x 440 140 x 480 1 000 1 000 1 000 1 000 50/60 50/60 176 176 387 387 106 106 232 232 30 976 30 976 0·009 0·007 0·006 0·006 0·011 0·009 0·011 0·008 0·013 0·010 0·009 0·007 0·009 0·007 0·006 0·006 0·069 0·065 0·012 0·011 0·018 0·017 0·017 0·016 0·019 0·015 0·016 0·013 0·017 0·013 0·023 0·022 0·030 0·026 0·028 0·025 0·029 0·026 0·071 0·062 0·055 0·042 0·090 0·075 0·077 0·061 0·088 0·075 0·117 0·097 10·5 8·9 10·8 8·9 10·9 9·0 11·0 9·0 11·0 8·9 10·9 8·6 9·8 7·3 126·0 158·0 134·0 174·0 126·0 163·0 23·8 26·3 55 55 B/F1 B/F1 541 636 -5/50 -5/50
Regulations and conformity : 1 : Class F thermal resistance (155°C) available on request IEC 61439-6 (BS EN 61439-6) +44 (0) 370 608 9020 Suitable for the following climates : In : rated current referred to a room temperature of 40°C Constant humid climate (IEC 60068 2 – 11) Cyclical humid climate (IEC 60068 2 – 30) Degree of protection : IP 55; IP x7 carrying lines available with accessories, on request - +44 (0) 370 608 9020 Insulation and surface treatment of the conductors : Insulated conductors for the whole length, aluminum copper-plated and tin-plated PE 1 PE 3 PE 2 Busbar casing material : Standard version Extra earth - aluminium Extra earth - copper 1·5 mm galvanised steel plate, pre-painted or stainless steel (available, if required, with special paint and/or with thickness 2 mm)
115
SCP super compact busbar – double neutral (aluminium) technical data
140
H
n Double neutral SCP2N (3L + 2N + PE) aluminium
2N L1 L2 L3 PE
Aluminium
Single bar
Rated current Casing overall dimensions Operating voltage Insulation voltage Frequency Rated short-time current for three-phase fault (1 s) Allowable peak current for three-phase fault Rated short-time current for single-phase fault (1 s) Allowable peak current for single-phase fault Rated short-time protection current (1 s) Protection circuit peak rated current Allowable specific energy for three-phase fault Phase resistance Phase reactance (50 Hz) Phase impedance Phase resistance at thermal conditions Phase impedance at thermal conditions Neutral resistance Resistance of the protective conductor (PE type 1) Resistance of the protective conductor (PE type 2) Resistance of the protective conductor (PE type 3) Reactance of the protective conductor (50 Hz) Resistance of the fault loop (PE 1) Resistance of the fault loop (PE 2) Resistance of the fault loop (PE 3) Reactance of the fault loop (50 Hz) Impedance of the fault loop (PE 1) Impedance of the fault loop (PE 2) Impedance of the fault loop (PE 3) Zero-sequence resistance phase - N Zero-sequence reactance phase - N Zero-sequence Impedance phase - N Zero-sequence resistance phase - PE Zero-sequence reactance phase - PE Zero-sequence Impedance phase - PE
Voltage drop factor with distributed load ∆V = k.L.Ie.10-6 [V]
k [V/m/A]10-6
Weight (PE 1) Weight (PE 2) Weight (PE 3) Fire load Degree of protection Thermal resistance class of the insulating materials Joule effect losses at rated current Min./max. ambient temperature
In [A] 630 L x H [mm] 140 x 130 Ue [V] 1 000 Ui [V] 1 000 f [Hz] 50/60 Icw [kA]rms 36 Ipk [kA] 76 Icw [kA]rms 22 Ipk [kA] 48 Icw [kA]rms 22 Ipk [kA] 48 I2t [MA2s] 1 296 R20 [mΩ/m] 0·077 X [mΩ/m] 0·023 Z [mΩ/m] 0·080 Rt [mΩ/m] 0·084 Z [mΩ/m] 0·087 R20 [mΩ/m] 0·039 RPE [mΩ/m] 0·121 RPE [mΩ/m] 0·035 RPE [mΩ/m] 0·050 XPE [mΩ/m] 0·080 Ro [mΩ/m] 0·205 Ro [mΩ/m] 0·119 Ro [mΩ/m] 0·134 Xo [mΩ/m] 0·10 Zo [mΩ/m] 0·230 Zo [mΩ/m] 0·158 Zo [mΩ/m] 0·169 Ro [mΩ/m] 0·147 Xo [mΩ/m] 0·198 Zo [mΩ/m] 0·247 Ro [mΩ/m] 0·581 Xo [mΩ/m] 0·263 Zo [mΩ/m] 0·638 cosϕ = 0·70 65·3 cosϕ = 0·75 67·9 cosϕ = 0·80 70·3 cosϕ = 0·85 72·5 cosϕ = 0·90 74·3 cosϕ = 0·95 75·5 cosϕ = 1·00 72·9 p [kg/m] 21·6 p [kg/m] 23·0 p [kg/m] 20·6 [kWh/m] 5·6 IP 55 – B/F1 P [W/m] 100 [°C] -5/50
800 1 000 1 250 140 x 130 140 x 130 140 x 130 1 000 1 000 1 000 1 000 1 000 1 000 50/60 50/60 50/60 42 50 75 88 110 165 25 30 45 55 66 99 25 30 45 55 66 99 1 764 2 500 5 625 0·057 0·057 0·046 0·017 0·017 0·015 0·059 0·059 0·048 0·063 0·068 0·055 0·066 0·070 0·057 0·029 0·029 0·023 0·121 0·121 0·121 0·035 0·035 0·035 0·050 0·050 0·050 0·078 0·078 0·048 0·184 0·189 0·176 0·098 0·103 0·090 0·113 0·118 0·105 0·10 0·10 0·06 0·207 0·212 0·187 0·137 0·140 0·110 0·148 0·152 0·123 0·135 0·135 0·132 0·180 0·180 0·166 0·225 0·225 0·212 0·519 0·519 0·369 0·229 0·229 0·191 0·567 0·567 0·416 48·9 51·9 42·9 50·9 54·1 44·6 52·7 56·1 46·2 54·4 58·0 47·7 55·8 59·6 48·9 56·7 60·8 49·7 54·9 59·1 48·0 21·3 21·3 23·4 22·8 22·8 26·4 20·4 20·4 24·0 6·9 6·9 7·5 55 55 55 B/F1 B/F1 B/F1 122 205 260 -5/50 -5/50 -5/50
Double bar 1 600 140 x 170 1 000 1 000 50/60 80 176 48 106 48 106 6 400 0·033 0·014 0·036 0·039 0·041 0·017 0·110 0·028 0·040 0·039 0·149 0·067 0·079 0·05 0·158 0·085 0·095 0·129 0·160 0·206 0·321 0·175 0·366 32·3 33·4 34·3 35·1 35·7 35·9 33·8 25·4 28·6 25·5 10·6 55 B/F1 300 -5/50
2 000 140 x 220 1 000 1 000 50/60 80 176 48 106 48 106 6 400 0·025 0·011 0·027 0·030 0·032 0·013 0·098 0·023 0·033 0·028 0·128 0·053 0·063 0·04 0·134 0·066 0·074 0·126 0·190 0·228 0·270 0·212 0·343 25·1 25·9 26·7 27·3 27·7 27·8 26·2 38·4 41·4 37·4 13·1 55 B/F1 363 -5/50
2 500 140 x 380 1 000 1 000 50/60 150 330 90 198 90 198 22 500 0·021 0·006 0·022 0·024 0·025 0·011 0·074 0·014 0·020 0·020 0·098 0·038 0·044 0·03 0·102 0·046 0·051 0·084 0·135 0·159 0·217 0·155 0·267 18·4 19·2 19·9 20·6 21·2 21·6 21·0 54·6 60·1 53·1 20·0 55 B/F1 455 -5/50
3 200 4 000 140 x 440 140 x 480 1 000 1 000 1 000 1 000 50/60 50/60 160 160 352 352 96 96 211 211 96 96 211 211 25 600 25 600 0·016 0·013 0·006 0·006 0·017 0·014 0·019 0·016 0·020 0·018 0·008 0·007 0·068 0·064 0·012 0·011 0·018 0·017 0·015 0·016 0·087 0·080 0·031 0·027 0·037 0·033 0·02 0·02 0·090 0·083 0·038 0·035 0·043 0·040 0·063 0·048 0·165 0·103 0·177 0·114 0·196 0·164 0·148 0·146 0·246 0·220 15·4 13·7 16·0 14·1 16·5 14·5 16·9 14·9 17·3 15·1 17·5 15·2 16·7 14·3 65·4 78·4 72·1 84·9 64·0 76·0 23·8 26·3 55 55 B/F1 B/F1 592 790 -5/50 -5/50
Regulations and conformity : 1 : Class F thermal resistance (155°C) available on request IEC 61439-6 (BS EN 61439-6) +44 (0) 370 608 9020 Suitable for the following climates : In : rated current referred to a room temperature of 40°C Constant humid climate (IEC 60068 2 – 11) Cyclical humid climate (IEC 60068 2 – 30) Degree of protection : IP 55; IP x7 carrying lines available with accessories, on request - +44 (0) 370 608 9020 Insulation and surface treatment of the conductors : Insulated conductors for the whole length, aluminum copper-plated and tin-plated PE 1 PE 3 PE 2 Busbar casing material : Standard version Extra earth - aluminium Extra earth - copper 1·5 mm galvanised steel plate, pre-painted or stainless steel (available, if required, with special paint and/or with thickness 2 mm)
116
SCP super compact busbar – double neutral (copper) technical data
140
H
n Double neutral SCP2N (3L + 2N + PE) copper
2N L1 L2 L3 PE
Copper
Single bar
Rated current Casing overall dimensions Operating voltage Insulation voltage Frequency Rated short-time current for three-phase fault (1 s) Allowable peak current for three-phase fault Rated short-time current for single-phase fault (1 s) Allowable peak current for single-phase fault Rated short-time protection current (1 s) Protection circuit peak rated current Allowable specific energy for three-phase fault Phase resistance Phase reactance (50 Hz) Phase impedance Phase resistance at thermal conditions Phase impedance at thermal conditions Neutral resistance Resistance of the protective conductor (PE type 1) Resistance of the protective conductor (PE type 2) Resistance of the protective conductor (PE type 3) Reactance of the protective conductor (50 Hz) Resistance of the fault loop (PE 1) Resistance of the fault loop (PE 2) Resistance of the fault loop (PE 3) Reactance of the fault loop (50 Hz) Impedance of the fault loop (PE 1) Impedance of the fault loop (PE 2) Impedance of the fault loop (PE 3) Zero-sequence resistance phase - N Zero-sequence reactance phase - N Zero-sequence Impedance phase - N Zero-sequence resistance phase - PE Zero-sequence reactance phase - PE Zero-sequence Impedance phase - PE
Voltage drop factor with distributed load ∆V = k.L.Ie.10-6 [V]
k [V/m/A]10-6
Weight (PE 1) Weight (PE 2) Weight (PE 3) Fire load Degree of protection Thermal resistance class of the insulating materials Joule effect losses at rated current Min./max. ambient temperature
In [A] 800 L x H [mm] 140 x 130 Ue [V] 1 000 Ui [V] 1 000 f [Hz] 50/60 Icw [kA]rms 45 Ipk [kA] 95 Icw [kA]rms 27 Ipk [kA] 57 Icw [kA]rms 27 Ipk [kA] 57 I2t [MA2s] 2 025 R20 [mΩ/m] 0·039 X [mΩ/m] 0·023 Z [mΩ/m] 0·045 Rt [mΩ/m] 0·042 Z [mΩ/m] 0·048 R20 [mΩ/m] 0·020 RPE [mΩ/m] 0·125 RPE [mΩ/m] 0·036 RPE [mΩ/m] 0·050 XPE [mΩ/m] 0·054 Ro [mΩ/m] 0·167 Ro [mΩ/m] 0·078 Ro [mΩ/m] 0·092 Xo [mΩ/m] 0·077 Zo [mΩ/m] 0·184 Zo [mΩ/m] 0·110 Zo [mΩ/m] 0·120 Ro [mΩ/m] 0·128 Xo [mΩ/m] 0·184 Zo [mΩ/m] 0·224 Ro [mΩ/m] 0·507 Xo [mΩ/m] 0·201 Zo [mΩ/m] 0·545 cosϕ = 0·70 39·9 cosϕ = 0·75 40·7 cosϕ = 0·80 41·3 cosϕ = 0·85 41·7 cosϕ = 0·90 41·7 cosϕ = 0·95 41·1 cosϕ = 1·00 36·7 p [kg/m] 39·0 p [kg/m] 41·0 p [kg/m] 38·0 [kWh/m] 5·6 IP 55 – B/F1 P [W/m] 81 [°C] -5/50
1 000 1 250 1 600 140 x 130 140 x 130 140 x 170 1 000 1 000 1 000 1 000 1 000 1 000 50/60 50/60 50/60 50 60 85 110 132 187 30 36 51 66 79 112 30 36 51 66 79 112 2 500 3 600 7 225 0·030 0·030 0·022 0·017 0·017 0·015 0·035 0·035 0·027 0·035 0·037 0·027 0·039 0·041 0·031 0·015 0·015 0·011 0·125 0·125 0·113 0·036 0·036 0·028 0·050 0·050 0·041 0·054 0·054 0·044 0·160 0·162 0·140 0·071 0·073 0·055 0·085 0·087 0·068 0·071 0·071 0·059 0·175 0·177 0·152 0·100 0·102 0·081 0·110 0·112 0·090 0·125 0·125 0·121 0·152 0·152 0·143 0·197 0·197 0·187 0·429 0·429 0·331 0·177 0·177 0·143 0·464 0·464 0·361 31·5 33·0 25·6 32·2 33·9 26·1 32·8 34·6 26·5 33·3 35·1 26·7 33·4 35·4 26·7 33·1 35·1 26·2 30·0 32·2 23·3 39·0 39·0 53·0 41·0 41·0 55·0 38·0 38·0 52·0 6·9 6·9 10·0 55 55 55 B/F1 B/F1 B/F1 104 174 207 -5/50 -5/50 -5/50
Double bar 2 000 140 x 170 1 000 1 000 50/60 88 194 53 116 53 116 7 744 0·018 0·014 0·023 0·022 0·026 0·009 0·113 0·028 0·041 0·044 0·135 0·050 0·063 0·058 0·147 0·077 0·086 0·117 0·127 0·173 0·283 0·150 0·320 22·1 22·4 22·6 22·7 22·5 22·0 19·1 58·0 60·0 57·0 10·3 55 B/F1 265 -5/50
2 500 140 x 220 1 000 1 000 50/60 88 194 53 116 53 116 7 744 0·014 0·011 0·018 0·017 0·020 0·007 0·101 0·023 0·033 0·032 0·118 0·040 0·050 0·043 0·126 0·059 0·066 0·094 0·122 0·154 0·221 0·124 0·253 17·1 17·4 17·5 17·5 17·4 17·0 14·7 86·0 83·0 79·0 13·1 55 B/F1 319 -5/50
3 200 140 x 380 1 000 1 000 50/60 170 374 102 224 102 224 28 900 0·011 0·007 0·013 0·013 0·015 0·006 0·075 0·014 0·021 0·022 0·088 0·027 0·034 0·029 0·093 0·040 0·045 0·088 0·078 0·118 0·177 0·111 0·209 12·2 12·4 12·6 12·8 12·8 12·6 11·2 105·0 111·0 104·0 20·0 55 B/F1 399 -5/50
4 000 5 000 140 x 440 140 x 480 1 000 1 000 1 000 1 000 50/60 50/60 176 176 387 387 106 106 232 232 106 106 232 232 30 976 30 976 0·009 0·007 0·006 0·006 0·011 0·009 0·011 0·008 0·013 0·010 0·005 0·003 0·069 0·065 0·012 0·011 0·018 0·017 0·017 0·016 0·080 0·073 0·023 0·019 0·029 0·025 0·023 0·022 0·083 0·077 0·033 0·029 0·037 0·034 0·065 0·046 0·076 0·073 0·100 0·086 0·178 0·144 0·094 0·086 0·201 0·168 10·5 8·9 10·8 8·9 10·9 9·0 11·0 9·0 11·0 8·9 10·9 8·6 9·8 7·3 126·0 158·0 134·0 174·0 126·0 163·0 23·8 26·3 55 55 B/F1 B/F1 541 636 -5/50 -5/50
Regulations and conformity : 1 : Class F thermal resistance (155°C) available on request IEC 61439-6 (BS EN 61439-6) +44 (0) 370 608 9020 Suitable for the following climates : In : rated current referred to a room temperature of 40°C Constant humid climate (IEC 60068 2 – 11) Cyclical humid climate (IEC 60068 2 – 30) Degree of protection : IP 55; IP x7 carrying lines available with accessories, on request - +44 (0) 370 608 9020 Insulation and surface treatment of the conductors : Insulated conductors for the whole length, aluminum copper-plated and tin-plated PE 1 PE 3 PE 2 Busbar casing material : Standard version Extra earth - aluminium Extra earth - copper 1·5 mm galvanised steel plate, pre-painted or stainless steel (available, if required, with special paint and/or with thickness 2 mm)
117
EXTENSIVE RANGE, HIGH P E R FO R M A N C E A N D S A F E T Y
DPX3 MCCBs
A comprehensive range for all your requirements from 16 to 1600 A
118
The DPX³ range features four sizes of moulded case circuit breakers with breaking capacities ranging from 16 to 100 kA. In
16
25
40
63
80
100 125 160 200 250 320 400 500 630 800 1000 1250 1600
DPX³ 160 16 kA
DPX³ 160 DPX³ 250
25 kA
DPX³ 160 DPX³ 250
36 kA
DPX³ 630 DPX³ 1 600 DPX³ 160 DPX³ 250
50 kA
DPX³ 630 DPX³ 1 600 DPX³ 250
70 kA
DPX³ 630 DPX³ 1 600
100 kA
DPX³ 630 DPX³ 1 600
Easy identification of the breaking capacity by the coloured tab:
DPX³ 160 Mounting on rail or plate
DPX³ 250 Mounting on rail or plate
DPX³ 630 Mounting on plate
16 kA
25 kA
36 kA
50 kA
70 kA
100 kA
DPX³ 1600 Mounting on plate
215 2 0A 100A
119
DPX3 electrical characteristics
DPX³ 160 thermal magnetic
DEVICES
DPX³ 250 thermal magnetic
On rail 4 or on plate
Mounting Breaking capacity (kA) (EN 60947-2 and IEC 60947-2)
DPX³ 250 electronic release
On rail 4 or on plate
16 kA
25 kA
36 kA
50 kA
25 kA
36 kA
50 kA
380/415 V±
16
25
36
50
25
36
220/240 V±
25
35
50
65
40
60
Breaking capacity (% Icu)
100
100
100
100
100
100
100
On rail 4 or on plate 70 kA
25 kA
36 kA
50 kA
70 kA
50
70
25
36
50
70
100
100
40
60
100
100
100
100
100
100
100
Characteristic of use 50/60 Hz
Nominal frequency 690 V (500 V with integrated e.l.c.bs)
690 V (500 V with integrated e.l.c.bs)
690 V (500 V with integrated e.l.c.bs)
A
A
A
Thermal
0.8 to 1 In
0.8 to 1 In
-
Magnetic
10 In (400 A for 16 A and 25 A sizes)
5 to 10 In
-
-
-
Ir : 0.4 to 1 In Isd : 1.5 to 10 Ir
Maximum rated operating voltage Ue Category of use Thermal magnetic adjustment
t
Ir Ii
I
Electronic protection adjustment
S2
t
Ir
tr Isd tsd I
Sg t(s)
t(s)
Ir Isd
lg tg
tr tsd li
I(A)
I(A)
Maximum cable cross-section
Standard version
150 mm2
150 mm2
150 mm2
70 mm2
120 mm2
120 mm2
120 mm2
95
Rigid cable Flexible cable Copper bar and lug width
High capacity
mm2
14 mm
18 mm
8 Nm
8 Nm
Tightening torque
28.5
mm(1)
28.5 mm1
10 Nm
10 Nm
Nominal current (In) at 40 °C (A) In (A)
16
25
40
63
80
100
125
160
100
160
200
250
40
100
160
250
Phase
16
25
40
63
80
100
125
160
100
160
200
250
40
100
160
250
N
16
25
40
63
80
100
125
160
100
160
200
250
-
-
-
-
-
-
-
-
-
-
-
-
N/2 Magnetic threshold (Im) (A)2 of DPX3 thermal magnetic
Fixed
Adjustable
0 - 50 -100 % of phase value3 -
-
-
Adjustable
In (A)
16
25
40
63
80
100
125
160
100
160
200
250
-
Phase
400
400
400
630
800
1000
1250
1600
125-250
200-400
315-630
500-1000
-
N
400
400
400
630
800
1000
1250
1600
125-250
200-400
315-630
500-1000
-
-
-
-
-
-
-
-
-
-
-
-
-
-
N/2 Endurance (cycles) Electrical
8000
8000
8000
Mechanical
25000
20000
20000
without or integrated
without or integrated
without or integrated
Electronic earth leakage module Type 1: Copper bars only 2: Trip current for 50/60 Hz. For direct current, multiply by 1.5 3: For maximum values related to In phase limit
120
-
DPX³ 630 thermal magnetic
DPX³ 630 electronic release
On plate 36 kA
50 kA
DPX³ 1600 thermal magnetic
On plate
70 kA
100 kA
36 kA
50 kA
DPX³ 1600 electronic release
On plate
70 kA
100 kA
36 kA
50 kA
On plate
70 kA
100 kA
36 kA
50 kA
70 kA
100 kA
36
50
70
100
36
50
70
100
36
50
70
100
36
50
70
100
70
100
120
170
70
100
120
170
70
100
120
170
70
100
120
170
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
50/60 Hz 690 V±
690 V±
690 V±
690 V±
A
A : In 630 A - B : In 200 to 400 A
A
B
0.8 to 1 In
-
0.8 to 1 In
-
5 to 10 In
-
5 to 10 In
-
-
S2
Sg
S2
Sg
Ir = 0.4 - 1 x In
•
•
Ir = 0.4 - 1 x In
•
•
tr = 3-30 s
•
•
tr = 3-30 s
•
•
Isd = 1.5 - 10 Ir
•
•
Isd = 1.5 - 10 Ir
•
•
tsd (I=K) = 0-500 ms
•
•
tsd (I=K) = 0-500 ms
•
•
tsd(I2t=K)
•
•
tsd(I2t=K) = 0-500 ms
•
Ig = 0.2 - 1 x In
•
Ig = 0.2 - 1 x In
•
tg = 0.1 - 1 s
•
tg = 0.1 - 1 s
•
= 0-500 ms
-
300 mm2 or 2 x 240 mm2
300 mm2 or 2 x 240 mm2
2 or 4 x 240 mm2
2 or 4 x 240 mm2
240 mm2 or 2 x 185 mm2
240 mm2 or 2 x 185 mm2
2 or 4 x 185 mm2
2 or 4 x 185 mm2
32 mm
50 mm
32 mm
•
50 mm
15 Nm
20 Nm
250
320
400
500
630
250
320
400
500
630
500
630
800
1000
1250
500
630
800
1000
1250
1600
250
320
400
500
630
250
320
400
500
630
500
630
800
1000
1250
500
630
800
1000
1250
1600
250
320
400
500
630
-
250
250
250
320
0 - 50 - 100 % of phase
value3
-
500
630
800
1000
1250
0 - 50 - 100 % of phase
-
-
-
500
630
-
value3
Adjustable 250
320
400
500
630
-
500
630
800
1000
1250
-
12502500 12502500
16003200 16003200
20004000 20004000
25005000 25005000
31506300 31506300
-
25005000 25005000
31506300 31506300
40008000 40008000
500010000 500010000
625012500 625012500
-
-
10002000
12502500
16002500
20004000
-
25005000
31505000
-
-
-
-
-
5000
5000
4000
4000
10000
20000
10000
10000
downstream e.l.c.bs.
downstream e.l.c.bs.
-
-
121
DPX³ 160/250
n Technical characteristics (at 40°) DPX³ 160 with electronic earth leakage module 25 kA 36 kA 50 kA 16-25-40-63-80-100-125-160 600 500 500 8 A 25 35 50 65 16 25 36 50 10 18 25 30 8 10 12 15 5 5 8 10 32 50 60 80 16 25 30 40 16 25 30 40 10 20 25 35 100 100 100 100 32 52.5 75.6 105 6.25 8.75 12.5 16.3 4 6.25 9 12.5 2.5 4.5 6.25 7.5 2 2.5 3 3.75 1.25 1.25 2 2.5
DPX³ 160 thermal magnetic
MCCBs 16 kA Nominal current In (A) Rated insulation voltage (V)
50-60Hz 50-60Hz Continuous
Rated operational voltage (V) Rated impulse withstand current Uimp (kV) Category of use
220/240 V± 380/415 V± 440 V± 480/500 V± 690 V± 125 V= (1) 250 V= (1) 400 V= (2) 500 V= (2)
Ultimate breaking capacity (kA) in AC
Ultimate breaking capacity (kA) in DC
Standard breaking capacity Ics (% Icu) Short-circuit making capacity lcm (kA)
25 16 10 8 5 32 16 16 10 100 32 6.25 4 2.5 2 1.25
415 V± 220/240 V± 380/415 V± 440 V± 480/500 V± 690 V±
Breaking capacity on 1 pole Isu (kA) For IT neutral earthing system
MCCBs
25 kA 36 kA 50 kA 16-25-40-63-80-100-125-160 800 690 500 8 A 35 50 65 25 36 50 18 25 30 10 12 15 5 8 10 50 60 80 25 30 40 25 30 40 20 25 35 100 100 100 52.5 75.6 105 8.75 12.5 16.3 6.25 9 12.5 4.5 6.25 7.5 2.5 3 3.75 1.25 2 2.5
16 kA
DPX³ 250 thermal magnetic 36 kA 50 kA 70 kA 100-160-200-250 800 (with integrated e.l.c.bs: 500) 690 (with integrated e.l.c.bs: 500) 500 8 A 40 60 80 100 25 36 50 70 20 30 40 60 10 25 30 40 8 16 18 20 50 72 80 90 25 36 40 45 30 45 50 55 25 36 40 45 100 100 100 100 10 15 20 25 6.25 9 12.5 17.5 5 7.5 10 15 2.5 6.25 7.5 10 2 4 4.5 5
DPX³ 250 electronic release 36 kA 50 kA 70 kA 40-100-160-250 800 (with integrated e.l.c.bs: 600) 690 (with integrated e.l.c.bs: 500) 500 8 A 40 60 80 100 25 36 50 70 20 30 40 60 10 25 30 40 8 16 20 50 72 80 90 25 36 40 45 30 45 50 55 25 36 40 45 100 100 100 100 15 15 20 25 6.25 9 12.5 17.5 5 7.5 10 15 2.5 6.25 7.5 10 -
25 kA
Nominal current In (A) Rated insulation voltage (V)
50-60Hz 50-60Hz Continuous
Rated operational voltage (V) Rated impulse withstand current Uimp (kV) Category of use
Ultimate breaking capacity (kA) in AC
220/240 V± 380/415 V± 440 V± 480/500 V± 690 V±
Ultimate breaking capacity (kA) in DC
125 V= 1 250 V= 1 400 V= 2 500 V= 2
Standard breaking capacity Ics (% Icu) 220/240 V± 380/415 V± 440 V± 480/500 V± 690 V±
Breaking capacity on 1 pole Isu (kA) For IT neutral earthing system
n Temperature derating
25 kA
n Derating at different altitudes
DPX3 160 In (A) 16 25 40 63 80 100 125 160
-25 23 37 55 88 115 135 160 224
-20 22 35 54 87 113 133 158 221
-10 21 34 52 84 111 130 155 214
Temperature (°C) 0 10 20 30 20 19 18 17 32 30 28 26 50 47 43 42 81 76 69 66 107 97 87 84 115 108 100 100 150 138 125 125 205 192 176 168
-5 21 33 51 83 109 123 153 210
40 16 25 40 63 80 100 125 160
50 15 23 38 60 78 95 118 152
60 15 22 36 57 75 90 112 145
DPX3 250 Temperature (°C)
In (A) -25
-20
-10
-5
0
10
20
30
40
50
60
70
40
54
53
51
50
49
48
45
41
40
38
36
34
100
135
132
128
126
123
120
112
102
100
94
90
84
160
216
211
205
201
197
192
179
163
160
151
143
134
200
270
264
256
251
246
240
224
203
200
189
179
168
250
338
330
320
314
308
300
280
254
250
236
224
210
1: 2 poles in series 2: 3 poles in series
122
70 14 21 34 55 72 85 105 139
Altitude (m)
2000
3000
4000
Rated current (A)
1 x In
0.96 x In
0.93 x In
Rated voltage (V)
DPX³ no e.l.c.bs
690
690
550
DPX³ with e.l.c.bs
500
500
400
DPX³ 160/250
n DPX3 160 thermal-magnetic tripping curve
n DPX3 250 thermal-magnetic tripping curves
10000
10000
t (s)
t (s)
1000
1000
100
100
1
1
10
10
2
2
1
1
In=40-160A Ii=10 xIn 0.1
In=25A Ii=16xIn In=16A Ii=25 xIn
0.01
0.001
In=100-250A Ii=5...10 xIn
0.1
0.01
1
10
16
I/Ir
25 I/In
100
0.001
1
5
10 I/Ir
100
t: time I: rated current Ir: setting current Curve n°1: charateristic with cold start Curve n°2: charateristic with hot start
t: time I: rated current Ir: setting current Curve n°1: charateristic with cold start Curve n°2: charateristic with hot start
n DPX3 160 thermal-magnetic with integrated e.l.c.bs
n DPX3 250 thermal-magnetic with integrated e.l.c.bs
tripping curves
10000
10000 t (s) t (s) 1000 1000
100 100
1
1 10 10
2 2
1
1
In=40-160A Ii=10 xIn 0.1
In=100-250A Ii=5...10 xIn
0.1
In=25A Ii=16xIn In=16A Ii=25 xIn 0.01
0.01
0.001 0.001
1
10 I/Ir
t: time I: rated current Ir: setting current Curve n°1: charateristic with cold start Curve n°2: charateristic with hot start
16
25 I/In
1
100
5
10 I/Ir
100
t: time I: rated current Ir: setting current
123
DPX³ 160/250 (continued)
DPX³ 630/1600 reading DPX³ characteristic curves and adjustment ranges
n DPX3 250 electronic release tripping curves 10000
n Tripping curve for a DPX³ thermal-magnetic trip 10 000
t(s)
t (s)
1000
Thermal realease zone when cold
1 000
100
tr = 15s (±20%) tr = 10s (±20%) tr = 5s (±20%) tr = 3s (±20%)
100
10
10
Isd=1.5Ir (±20%) 1
In=250A
tsd=0.5s (±20%)
In=40A
1
I2t=K
0.1 tsd=0s (±20%)
Thermal realease zone when hot
Adjustable magnetic realease zone
HIGH selectivity LOW selectivity
0.1
0.01
Im
t < 10ms
0.001 1
10 I/Ir
100 1
10 I/In
100
0.01
0.001
n Adjustment for thermal-magnetic DPX3 Setting
DPX3 thermal magnetic
lr overload trip threshold (thermal) lm short-circuit trip threshold (magnetic) I∆
DPX3 with integrated e.l.c.bs
0.4 to 1 ln
0.4 to 1 ln
ixed: 10 ln1
ixed: 10 ln1
-
0.03 - 0.03 - 1 - 3
-
0 - 0.3 - 1 - 3
n (A)
∆t (s) 1: 400 A for DPX3 160 In 16 A and 25 A
n Adjustment for DPX3 electronic release Setting lr overload trip threshold (long delay) tr long delay trip time lsd short-circuit trip threshold (short delay) tsd short delay trip time
DPX3
DPX3 with integrated e.l.c.bs 0.4 to 1 ln 3 - 5 - 10 - 15s
1.5 - 2 - 2.5 - 3 - 4 - 5 - 6 - 7 - 8 - 9 10 x lr 0.01 - 0.1 - 0.2 - 0.3 - 0.4 - 0.5s
Ig
(0.2 - 0.3 - 0.4 - 0.5 - 0.6 - 0.7 - 0.8 - 1 - OFF) x ln
tg
0.1 - 0.2 - 0.5 - 1s
124
1
2
3 4 5
10
20
30
50
100 I/Ir
I: actual current Ir: thermal protection against overloads (setting: Ir = x In) Im: magnetic protection against short-circuits (setting: Im = x In or Im = x Ir) As the abscissa of the curves represents the ratio I/Ir, modifying the setting of Ir will not change the graphical representation of the thermal trip. However, the magnetic setting can be read directly (between 3.5 and 10 in the example).
DPX³ 630/1600 reading DPX³ characteristic curves and adjustment ranges
n Tripping curve for a DPX³ electronic release S1, adjustable Ir and Isd
I: actual current Ir: long delay protection against overloads (setting: Ir = x In) lsd: long delay protection operation time (fixed value: 5 s at 6 Ir) Isd: short delay protection against short-circuits (setting: Im = x Ir, between 1.5 and 10 Ir in the example) tsd: short delay protection operation time (fixed value: 0.05 s) If: fixed threshold instantaneous protection (4 to 20 kA depending on model)
10 000 t (s) 1 000
100 Isf = 40 A
10 tr = 5 s
Isf = 160 A
Isf = 250 A
1
Isf = 160 A
Isd
Isf = 630 A Isf = 1250 A
Isf = 400 A
Isf = 100 A
0.1
Isf = 1600 A
Isf = 630 A
Isf = 250 A
Isf = 800 A
0.01
0.001 0.2 1
2 3 4 56 10 I/Ir
10
20 30 40 50 70 I/In
10
20 30 10 I/In
20 I/In
n Tripping curve for a DPX³ electronic release S2, adjustable Ir, Isd, tr and tsd
I: actual current Ir: long delay protection against overloads (setting: Ir = x In) tr: long delay protection operation time (fixed value: 5 to 30 s) Isd: short delay protection against short-circuits (setting: Im = x Ir, between 1.5 and 10 Ir in the example) tsd: short delay protection operation time (setting: 0 to 0.3 s) I2t constant (adjustable via tsd) If: fixed threshold instantaneous protection (4 to 20 kA depending on model)
10 000 t (s) tr = 30 s 20 % tr = 20 s 20 % tr = 10 s 20 %
1 000
tr = 5 s 20 %
100
Isf = 250 A Isf = 160 A
10
Isf = 100 A Isf = 40 A
I2t = K Isd
1
Isf = 630 A Isf = 400 A
Isf = 1600 A Isf = 1250 A
Isf = 160 A Isf = 250 A
Isf = 630 A Isf = 800 A
0.1 Tsd 0.01
0.001 0.2 1
2
3 4 5 I/Ir
10
10
20 304050 I/In
n Adjustment for thermal-magnetic DPX³
10
20 30 10 I/In
20 30 I/In
n Adjustment for DPX³ electronic release
Setting
DPX³ 630
DPX³ 1600
Setting
Ir overload trip threshold (thermal)
0.8 to 1 In
0.8 to 1 In
Ir overload trip threshold (long delay)
Im short-circuit trip threshold (magnetic)
5 to 10 In
5 to 10 In
DPX³ 630 / 1600 S1
DPX³ 630 / 1600 S2
(0.4 - 0.5 - 0.6 - 0.7 - 0.8 - 0.9 - 0.95 - 1) x In
tr long delay fixed: 5 s (to 6 Ir)
5 - 10 - 20 - 30 s (to 6 Ir)
trip time Isd short-circuit trip threshold (short delay)
(1.5 - 2 - 3 - 4 - 5 - 6 - 8 - 10) x Ir1
tsd Short delay fixed: 0.05 s
0 - 0.1 - 0.2 - 0.3 s
trip time 1: 7.9 Ir for DPX³ 630 In 630 A
125
Cat. Nos.
Page No.
650 652EFB01 652EFB02 652EFB04 652EFB51 652EFB52 652EFB54 653EFB02 653EFB03 653EFB04 653EFB52 653EFB53 653EFB54 653IFB01
69 – – – – – – – – – – – –
5000 00 515EFB01 IFB01 554EFB01 EFB02 IFB01 IFB02 IFB03 IFB04 IFB05 IFB06 IFB07 IFB08 IFB09 557300 597013
21 – 31 – – – – – – – – – – 11 –
500000 00 50400101 00102 00103 00104 00105 00106 00107 00108 50400111 00112 00113 00114 00115 00116 00117 00118 50400121 00122 00123 00124 00125 00126 00127 00128 50400141 00142 00143 00144 00145 00146 00147 00148 50400151 00152 00153 00154 00155 00156 00157 00158 00241 00242 00243 00244 00245 00246 00247 00248 00251 00252 00253 00254 00255 00256 00257 00258 50400301 00302 00303 00304 00305 00306 00307 00308 00311 00312 00313 00314 00315 00316 00317 00318 00321 00322 00323 00324 00325 00326 00327 00328 00331 00332 00333 00334 00335 00336 00337 00338 50400341 00342 00343 00344 00345 00346 00347 00348 00351 00352 00353 00354
126
30 – – – – – – – 31 – – – – – – – 30 – – – – – – – 31 – – – – – – – 30 – – – – – – – – – – – – – – – – – – – – – – – 32 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 33 – – – – – – – – – – –
Cat. Nos. 50400355 00356 00357 00358 00361 00362 00363 00364 00365 00366 00367 00368 00371 00372 00373 00374 00375 00376 00377 00378 50400401 00402 00403 00404 00405 00406 00407 00408 00411 00412 00413 00414 00415 00416 00417 00418 00421 00422 00423 00424 00425 00426 00427 00428 00431 00432 00433 00434 00435 00436 00437 00438 50400441 00442 00443 00444 00445 00446 00447 00448 00451 00452 00453 00454 00455 00456 00457 00458 00461 00462 00463 00464 00465 00466 00467 00468 00471 00472 00473 00474 00475 00476 00478 50400501 00502 00503 00504 00505 00506 00507 00508 00511 00512 00513 00514 00515 00516 00517 00518 00521 00522 00523 00524 00525 00526 00527 00528 00531 00532 00533 00534 00535 00536 00537 00538 00541 00542 00543 00544 00545 00546 00547 00548 00551 00552 00553 00554 00555 00556 00557 00558 00561 00562 00563 00564 00565 00566
Page No. 33 – – – – – – – – – – – – – – – – – – – 32 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 33 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 34 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – –
Cat. Nos. 50400567 00568 00571 00572 00573 00574 00575 00576 00577 00578 50400601 00602 00603 00604 00605 00606 00607 00608 00611 00612 00613 00614 00615 00616 00617 00618 00621 00622 00623 00624 00625 00626 00627 00628 00631 00632 00633 00634 00635 00636 00637 00638 00641 00642 00643 00644 00645 00646 00647 00648 00651 00652 00653 00654 00655 00656 00657 00658 00661 00662 00663 00664 00665 00666 00667 00668 00671 00672 00673 00674 00675 00676 00677 00678 50400701 00702 00703 00704 00705 00706 00707 00708 00711 00712 00713 00714 00715 00716 00717 00718 00721 00722 00723 00724 00725 00726 00727 00728 00731 00732 00733 00734 00735 00736 00737 00738 00741 00742 00743 00744 00745 00746 00747 00748 00751 00752 00753 00754 00755 00756 00757 00758 00761 00762 00763 00764 00765 00766 00767 00768 00771 00772 00773 00774 00775 00776 00777
Page No.
Cat. Nos.
34 – – – – – – – – – 35 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 36 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – –
50400778 50401001 01002 01003 01004 01005 01006 01007 01008 01011 01012 01013 01014 01015 01016 01017 01018 01101 01102 50401111 01112 01121 01122 01123 01124 01125 01126 01127 01128 01131 01132 01133 01134 01135 01136 01137 01138 50401201 01202 01203 01204 01205 01206 01207 01208 01701 01702 01703 01704 01705 01706 01707 01708 01721 01722 01723 01724 01725 01726 01727 01728 50401801 01802 01803 01804 01805 01806 50403001 03002 03003 03004 03005 03006 03007 03008 50403101 03102 03401 03402 03403 03404 03405 03406 03407 03408 03411 03412 03413 03414 03415 03416 03417 03418 03421 03422 03423 03424 03425 03426 03427 03428 03431 03432 03433 03434 03435 03436 03437 03438 50403601 50403711 03712 50404004 04024 11601 11622 11623 11624 11625 11646 14001 14002 14003 50414003M3MC 3M3MD 3M3ME 3M3MF 3M3RA 3M3RB 3M3RC 3M3RD 3M3RE 3M3RF 50414003M4RA 3M4RB 3M4RC 3M4RD
Page No. 36 38 – – – – – – – – – – – – – – – – – 37 – – – – – – – – – – – – – – – – – 38 – – – – – – – – – – – – – – – – – – – – – – – 41 – – – – – 36 – – – – – – 37 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 31 42 – 40 – – – – – – – – – – 41 – – – – – – – – – 41 – – –
Cat. Nos.
Page No.
50414003M4RE 3M4RF 50414004 50414004M3RG 4M3RH 4M4RG 4M4RH 50414005 50414005M3RI 5M3RJ 5M4RI 5M4RJ 50414021 14022 14023 50414024 14025 14026 50414063 14064 14130 14143 14144 50414181 14185 14192 14241 14281 14282 14291 50632001 32003 32205 32212 32213 32214 51002002 02160 02161 51002361 02362 02461 02462 02561 02562 02563 02564 02661 51501351 51510101 10102 10112 10113 10114 10115 10116 51511051 11052 11151 11261 51515051 15052 15056 15057 15058 15067 15071 15072 15073 15074 15075 51520101 20102 20112 20113 20114 20115 20116 51520351 20361 20451 20461 20551 20561 20571 20581 20651 51521051 21052 21151 21261 51530101 30102 30112 30113 30114 30115 30116 51530351 30361 30451 30461 30551 30561 30571 30581 30651 515EFB01 515IFB01
41 – 40 41 – – – 41 – – – – 40 – – 41 – – 39 – – – – – – – – – – – 42 – – – – – 23 – – 22 – – – – – – – – 23 21 – – – – – – 22 – – – 23 – – – – – – – – – – 21 – – – – – – 22 – – – – – – – – – – – – 21 – – – – – – 22 – – – – – – – – 21 –
55055053 55055 55056 55062 55063 55055068 55070 55071 55077 55055077M3TA 7M3TB 7M3TC 7M3TD 7M3TE 7M3TF 7M4TA 55055077M4TB 7M4TC 7M4TD 7M4TE 7M4TF 55055086 55088 55400102 00103 00104 00105
40 – – – – 40 – – – 41 – – – – – – 41 – – – – 40 – 30 – – –
550000 00
Cat. Nos. 55400106 00107 55400112 00113 00114 00115 00116 00117 55400122 00123 00124 00125 00126 00127 55400142 00143 00144 00145 00146 00147 55400152 00153 00154 00155 00156 00157 00242 00243 00244 00245 00246 00247 00252 00253 00254 00255 00256 00257 55400302 00303 00304 00305 00306 00307 00312 00313 00314 00315 00316 00317 00322 00323 00324 00325 00326 00327 00332 00333 00334 00335 00336 00337 55400342 00343 00344 00345 00346 00347 00352 00353 00354 00355 00356 00357 00362 00363 00364 00365 00366 00367 00372 00373 00374 00375 00376 00377 55400402 00403 00404 00405 00406 00407 00412 00413 00414 00415 00416 00417 00422 00423 00424 00425 00426 00427 00432 00433 00434 00435 00436 00437 55400442 00443 00444 00445 00446 00447 00452 00453 00454 00455 00456 00457 00462 00463 00464 00465 00466 00467 00472 00473 00474 00475 00476 00477 55400502 00503 00504
Page No. 30 – 31 – – – – – 30 – – – – – 31 – – – – – 30 – – – – – – – – – – – – – – – – – 32 – – – – – – – – – – – – – – – – – – – – – – – 33 – – – – – – – – – – – – – – – – – – – – – – – 32 – – – – – – – – – – – – – – – – – – – – – – – 33 – – – – – – – – – – – – – – – – – – – – – – – 34 – –
Cat. Nos. 55400505 00506 00507 00512 00513 00514 00515 00516 00517 00522 00523 00524 00525 00526 00527 00532 00533 00534 00535 00536 00537 00542 00543 00544 00545 00546 00547 00552 00553 00554 00555 00556 00557 00562 00563 00564 00565 00566 00567 00572 00573 00574 00575 00576 00577 55400602 00603 00604 00605 00606 00607 00612 00613 00614 00615 00616 00617 00622 00623 00624 00625 00626 00627 00632 00633 00634 00635 00636 00637 00642 00643 00644 00645 00646 00647 00652 00653 00654 00655 00656 00657 00662 00663 00664 00665 00666 00667 00672 00673 00674 00675 00676 00677 55400702 00703 00704 00705 00706 00707 00712 00713 00714 00715 00716 00717 00722 00723 00724 00725 00726 00727 00732 00733 00734 00735 00736 00737 00742 00743 00744 00745 00746 00747 00752 00753 00754 00755 00756 00757 00762 00763 00764 00765 00766 00767 00772 00773
Page No. 34 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 35 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 36 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – –
Cat. Nos. 55400774 00775 00776 00777 55401002 01003 01004 01005 01006 01007 01012 01013 01014 01015 01016 01017 55401102 01112 01122 01123 01124 01125 01126 01127 01132 01133 01134 01135 01136 01137 55401202 01203 01204 01205 01206 01207 01702 01703 01704 01705 01706 01707 01722 01723 01724 01725 01726 01727 55401801 01802 01803 01804 01805 01806 55403002 03003 03004 03005 03006 03007 55403402 03403 03404 03405 03406 03407 03412 03413 03414 03415 03416 03417 03422 03423 03424 03425 03426 03427 03432 03433 03434 03435 03436 03437 55655051 55057 55058 55059
Page No. 36 – – – 38 – – – – – – – – – – – 37 – – – – – – – – – – – – – 38 – – – – – – – – – – – – – – – – – 41 – – – – – 36 – – – – – 37 – – – – – – – – – – – – – – – – – – – – – – – 40 – – –
600000 00 60280100P 80101P 80102P 80104P 80106P 80107P 80120P 80121P 80122P 80124P 80126P 80127P 60280130P 80131P 80132P 80134P 80136P 80137P 60280150P 80151P 80152P 80154P 80156P 80157P 80170P 80171P 80172P 80174P 80176P 80177P 80180P 80181P 80182P 80184P 80186P 80187P 60280290P 80291P 80292P 80294P 80296P 80297P 60280300P 80301P 80302P 80304P
66 – – – – – – – – – – – 67 – – – – – 66 – – – – – – – – – – – – – – – – – 68 – – – – – 70 – – –
Cat. Nos. 60280306P 80307P 80310P 80311P 80312P 80314P 80316P 80317P 80320P 80321P 80322P 80324P 80326P 80327P 80330P 80331P 80332P 80334P 80336P 80337P 60280340P 80341P 80342P 80344P 80346P 80347P 80350P 80351P 80352P 80354P 80356P 80357P 60280400P 80401P 80402P 80404P 80406P 80407P 80410P 80411P 80412P 80414P 80416P 80417P 80420P 80421P 80422P 80424P 80426P 80427P 80430P 80431P 80432P 80434P 80436P 80437P 60280440P 80441P 80442P 80444P 80446P 80447P 80450P 80451P 80452P 80454P 80456P 80457P 60280700P 80701P 80702P 80704P 80706P 80707P 80710P 80711P 80712P 80714P 80716P 80717P 80720P 80721P 80722P 80724P 80726P 80727P 80730P 80731P 80732P 80734P 80736P 80737P 60280800P 80801P 80802P 80804P 80806P 80807P 80810P 80811P 80812P 80814P 80816P 80817P 80820P 80821P 80822P 80824P 80826P 80827P 80830P 80831P 80832P 80834P 80836P 80837P 60280920P 80921P 80922P 80924P 80926P 80927P 80950P 80951P 80952P 80954P 80956P 80957P 80970P 80971P 80972P 80974P 80976P 80977P 80980P 80981P 80982P
Page No. 70 – – – – – – – – – – – – – – – – – – – 72 – – – – – – – – – – – 71 – – – – – – – – – – – – – – – – – – – – – – – 72 – – – – – – – – – – – 74 – – – – – – – – – – – – – – – – – – – – – – – 73 – – – – – – – – – – – – – – – – – – – – – – – 67 – – – – – – – – – – – – – – – – – – – –
Cat. Nos. 60280984P 80986P 80987P 60281000P 81001P 81002P 81004P 81006P 81007P 81010P 81011P 81012P 81014P 81016P 81017P 81020P 81021P 81022P 81024P 81026P 81027P 81030P 81031P 81032P 81034P 81036P 81037P 60281100P 81101P 81102P 81104P 81106P 81107P 81110P 81111P 81112P 81114P 81116P 81117P 60281300P 81301P 81302P 81304P 81306P 81307P 81310P 81311P 81312P 81314P 81316P 81317P 81320P 81321P 81322P 81324P 81326P 81327P 81330P 81331P 81332P 81334P 81336P 81337P 60281400P 81401P 81402P 81404P 81406P 81407P 81410P 81411P 81412P 81414P 81416P 81417P 81420P 81421P 81422P 81424P 81426P 81427P 81430P 81431P 81432P 81434P 81436P 81437P 60287100P 87101P 87102P 87104P 87106P 87107P 87140P 87141P 87142P 87144P 87146P 87147P 60390104P 90106P 90107P 90124P 90126P 90127P 60390134P 90136P 90137P 60390154P 90156P 90157P 90174P 90176P 90177P 90184P 90186P 90187P 60390294P 90296P 90297P 60390304P 90306P 90307P 90314P 90316P 90317P 90324P 90326P 90327P 90334P 90336P 90337P 60390344P 90346P 90347P 90354P 90356P
Page No. 67 – – 75 – – – – – – – – – – – – – – – – – – – – – – – 77 – – – – – – – – – – – 76 – – – – – – – – – – – – – – – – – – – – – – – 77 – – – – – – – – – – – – – – – – – – – – – – – 68 – – – – – – – – – – – 66 – – – – – 67 – – 66 – – – – – – – – 68 – – 70 – – – – – – – – – – – 72 – – – –
Cat. Nos. 60390357P 60390404P 90406P 90407P 90414P 90416P 90417P 90424P 90426P 90427P 90434P 90436P 90437P 60390444P 90446P 90447P 90454P 90456P 90457P 60390704P 90706P 90707P 90714P 90716P 90717P 90724P 90726P 90727P 90734P 90736P 90737P 60390804P 90806P 90807P 90814P 90816P 90817P 90824P 90826P 90827P 90834P 90836P 90837P 60390924P 90926P 90927P 90954P 90956P 90957P 90974P 90976P 90977P 90984P 90986P 90987P 60391004P 91006P 91007P 91014P 91016P 91017P 91024P 91026P 91027P 91034P 91036P 91037P 60391104P 91106P 91107P 91114P 91116P 91117P 60391304P 91306P 91307P 91314P 91316P 91317P 91324P 91326P 91327P 91334P 91336P 91337P 60391404P 91406P 91407P 91414P 91416P 91417P 91424P 91426P 91427P 91434P 91436P 91437P 60397104P 97106P 97107P 97144P 97146P 97147P
Page No. 72 71 – – – – – – – – – – – 72 – – – – – 74 – – – – – – – – – – – 73 – – – – – – – – – – – 67 – – – – – – – – – – – 75 – – – – – – – – – – – 77 – – – – – 76 – – – – – – – – – – – 77 – – – – – – – – – – – 68 – – – – –
650000 00 65202001 02002 02004 02013 02112 02113 02114 65213701 13702 13704 13711 13712 13714 13721 13722 13724 13732 13733 13734 13742 13743 13744 13752 13753 13754 13761 13762 13764 13772 13773 13774
80 – – – – – – 81 – – – – – – – – – – – – – – – – – – – – – – –
Cat. Nos.
Page No.
65213782 13783 13784 13792 13793 13794 65222002 22003 22004 65245001P 5002P 65245002PM4RD 002PM4RE 65245003P 65245003PM4RB 003PM4RC 003PMFD 003PMFE 003PM4RF 65245004P 65245004PM4RG 004PM4RH 65245006P 65245006PM4RI 006PM4RJ 65245021P 45022P 45023P 45024P 45026P 45041P 45042P 45043P 45044P 45045P 45066P 65255011P 65255012P 65255013P 65255013PM4RB 013PM4RC 013PM4RD 013PM4RE 013PM4RF 65255014P 65255014PM4RG 014PM4RH 65255016P 65255016PM4RI 016PM4RJ 65255031P 55032P 55033P 55034P 55036P 55051P 55052P 55053P 55054P 55055P 55076P 65280100P 80101P 80103P 80105P 80106P 80108P 80120P 80121P 80123P 80125P 80126P 80128P 65280130P 80131P 80133P 80135P 80136P 80138P 65280150P 80151P 80153P 80155P 80156P 80158P 80170P 80171P 80173P 80175P 80176P 80178P 80180P 80181P 80183P 80185P 80186P 80188P 65280290P 80291P 80293P 80295P 80296P 80298P 65280300P 80301P 80303P 80305P 80306P 80308P 80310P 80311P 80313P 80315P 80316P 80318P 80320P 80321P 80323P 80325P 80326P 80328P 80330P 80331P 80333P 80335P 80336P 80338P 65280340P 80341P 80343P 80345P 80346P 80348P 80350P 80351P 80353P 80355P
82 – – – – – 80 – – 78 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 66 – – – – – – – – – – – 67 – – – – – 66 – – – – – – – – – – – – – – – – – 68 – – – – – 70 – – – – – – – – – – – – – – – – – – – – – – – 72 – – – – – – – – –
Cat. Nos. 65280356P 80358P 65280400P 80401P 80403P 80405P 80406P 80408P 80410P 80411P 80413P 80415P 80416P 80418P 80420P 80421P 80423P 80425P 80426P 80428P 80430P 80431P 80433P 80435P 80436P 80438P 65280440P 80441P 80443P 80445P 80446P 80448P 80450P 80451P 80453P 80455P 80456P 80458P 65280700P 80701P 80703P 80705P 80706P 80708P 80710P 80711P 80713P 80715P 80716P 80718P 80720P 80721P 80723P 80725P 80726P 80728P 80730P 80731P 80733P 80735P 80736P 80738P 65280800P 80801P 80803P 80805P 80806P 80808P 80810P 80811P 80813P 80815P 80816P 80818P 80820P 80821P 80823P 80825P 80826P 80828P 80830P 80831P 80833P 80835P 80836P 80838P 65280920P 80921P 80923P 80925P 80926P 80928P 80950P 80951P 80953P 80955P 80956P 80958P 80970P 80971P 80973P 80975P 80976P 80978P 80980P 80981P 80983P 80985P 80986P 80988P 65281000P 81001P 81003P 81005P 81006P 81008P 81010P 81011P 81013P 81015P 81016P 81018P 81020P 81021P 81023P 81025P 81026P 81028P 81030P 81031P 81033P 81035P 81036P 81038P 65281100P 81101P 81103P
Page No.
Cat. Nos.
Page No.
72 – 71 – – – – – – – – – – – – – – – – – – – – – – – 72 – – – – – – – – – – – 74 – – – – – – – – – – – – – – – – – – – – – – – 73 – – – – – – – – – – – – – – – – – – – – – – – 67 – – – – – – – – – – – – – – – – – – – – – – – 75 – – – – – – – – – – – – – – – – – – – – – – – 77 – –
65281105P 81106P 81108P 81110P 81111P 81113P 81115P 81116P 81118P 65281300P 81301P 81303P 81305P 81306P 81308P 81310P 81311P 81313P 81315P 81316P 81318P 81320P 81321P 81323P 81325P 81326P 81328P 81330P 81331P 81333P 81335P 81336P 81338P 65281400P 81401P 81403P 81405P 81406P 81408P 81410P 81411P 81413P 81415P 81416P 81418P 81420P 81421P 81423P 81425P 81426P 81428P 81430P 81431P 81433P 81435P 81436P 81438P 65281811P 81812P 81814P 81821P 81822P 81824P 81831P 81832P 81834P 81851P 81852P 81854P 81861P 81862P 81864P 81871P 81872P 81874P 82001P 82002P 82003P 65283101P 83102P 83104P 65285011P 65285012P 65285013P 65285013PM4RB 013PM4RC 013PM4RD 013PM4RE 013PM4RF 65285014P 65285014PM4RG 014PM4RH 65285016P 65285016PM4RI 016PM4RJ 65285031P 85032P 85033P 85034P 85036P 85051P 85052P 85053P 85054P 85055P 85076P 65286041P 86042P 86044P 65287100P 87101P 87103P 87105P 87106P 87108P 87140P 87141P 87143P 87145P 87146P 87148P 65390105P 90106P 90108P 90125P 90126P 90128P 65390135P 90136P 90138P 65390155P 90156P 90158P 90175P 90176P 90178P 90185P
77 – – – – – – – – 76 – – – – – – – – – – – – – – – – – – – – – – – 77 – – – – – – – – – – – – – – – – – – – – – – – 79 – – – – – – – – – – – – – – – – – – – – 69 – – 78 – – 78 – – – – – 78 – – 78 – 78 – – – – – – – – – – 79 – – 68 – – – – – – – – – – – 66 – – – – – 67 – – 66 – – – – – –
Cat. Nos. 65390186P 90188P 65390295P 90296P 90298P 65390305P 90306P 90308P 90315P 90316P 90318P 90325P 90326P 90328P 90335P 90336P 90338P 65390345P 90346P 90348P 90355P 90356P 90358P 65390405P 90406P 90408P 90415P 90416P 90418P 90425P 90426P 90428P 90435P 90436P 90438P 65390445P 90446P 90448P 90455P 90456P 90458P 65390705P 90706P 90708P 90715P 90716P 90718P 90725P 90726P 90728P 90735P 90736P 90738P 65390805P 90806P 90808P 90815P 90816P 90818P 90825P 90826P 90828P 90835P 90836P 90838P 65390925P 90926P 90928P 90955P 90956P 90958P 90975P 90976P 90978P 90985P 90986P 90988P 65391005P 91006P 91008P 91015P 91016P 91018P 91025P 91026P 91028P 91035P 91036P 91038P 65391105P 91106P 91108P 91115P 91116P 91118P 65391305P 91306P 91308P 91315P 91316P 91318P 91325P 91326P 91328P 91335P 91336P 91338P 65391405P 91406P 91408P 91415P 91416P 91418P 91425P 91426P 91428P 91435P 91436P 91438P 65391812P 91813P 91814P 91822P 91823P 91824P 91832P 91833P 91834P 91852P 91853P 91854P 91862P 91863P 91864P 91872P 91873P 91874P
Page No. 66 – 68 – – 70 – – – – – – – – – – – 72 – – – – – 71 – – – – – – – – – – – 72 – – – – – 74 – – – – – – – – – – – 73 – – – – – – – – – – – 67 – – – – – – – – – – – 75 – – – – – – – – – – – 77 – – – – – 76 – – – – – – – – – – – 77 – – – – – – – – – – – 79 – – – – – – – – – – – – – – – – –
Cat. Nos. 65393102P 93103P 93104P 65396042P 96043P 96044P 65397105P 97106P 97108P 97145P 97146P 97148P
Page No. 69 – – 79 – – 68 – – – – –
700000 00 71000104 75003000 03001 03002 03004 03005 03006 03008 03009 75005000 05005 05011 05012 05013 05014 05021 05022 05023 05024 05100 05200 06005 06205 75105000 05001 75150101 60101 60102 75161001 75170101 80101 80102 75200101 00102 00111 75201001 01002 01151 01261 75220101 20102 20111 75221001 21002 21151 21261 75240101 40102 40111 75241001 41002 41151 41261 75350102H 60102H 60103H 70101H 80101H 80102H 75400102H 00103H 00111H 20101H 20102H 20111H 40101H 40102H 40111H 750051001L1 51001L2 51001L3 51001LN2 510014C 51003L1 51003L2 51003L3 51003LN2 510034C
11 11 – – – – – – – 10 – – – – – – – – – – – – – 10 – 8 – – 9 8 – – – – – 9 – – – 8 – – 9 – – – 8 – – 9 – – – 8 – – – – – 8 – – – – – – – – 10 – – – – – – – – –
E EEA313 EEC348 EEC353
11 – –
F FC100010 FC100020 FC100030 FC100099 FC200010 FC200020 FC200030 FC200099 FC300010 FC300020 FC300030 FC300099 FC400010 FC400020 FC400030 FC400099 FC500010 FC500020 FC500030 FC500099 FC600010 FC600020 FC600030 FC600099 FC700010 FC700020 FC700030 FC700099
83 – – – – – – – – – – – – – – – – – – – – – – – – – – –
S SF766040 SF927140
82 –
127
Protection classifications Protection against solid bodies and liquids : Index of protection - IP xx Degree of protection of enclosures of electrical equipment in accordance with standards IEC 60529, BS EN 60529 Up to 1 000 V and 1 500 V=
±
1st digit: protection against solid bodies IP
tests
0
Ø 50 mm
No protection Ø 50 mm
Protected against solid bodies larger than 50 mm
1
Ø 12.5 mm
2
3
2nd digit: Additional letter IP XX protetion against liquids (ABCD): protection against direct contact resulting from IP tests the access to hazardous current-carrying parts No protection 0 IP tests protection
A
d
Protected Ø 2.5 mm against solid bodies larger than 2.5 mm
1 The back of the hand remains remote from dangerous parts
B
C
The dangerous parts can not be touched when introducing a finger
The dangerous parts can not be touched when introducing a tool (eg a screwdriver)
According to standards IEC 62262 and BS EN 62262
IK
Protected against drops of water falling at up to 15° from the vertical
0
IK 00 0.2 kg IK 01
Ø 1 mm
Protected against solid bodies larger than 1 mm
75 mm
0.15
100 mm
0.2
175 mm
0.35
250 mm
0.5
350 mm
0.7
0.2 kg
0.2 kg IK 03 0.2 kg
Protected against drops of rain water at up to 60° from the vertical
60
3
IK 04 0.2 kg IK 05
4
Protected against projections of water from all directions
5
Protected against jets of water from all directions
0.5 kg IK 06
200 mm
1
0.5 kg IK 07
400 mm
6
Protected against jets of water of similar force to heavy seas
7
Protected against the effects of immersion
2
1.7 kg IK 08
4
Impact energy (in Joules)
Tests
IK 02
2 12 mm
Protected against solid bodies larger than 12.5 mm
Protected against vertically-falling drops of water (condensation)
Protection against mechanical impact : Index of protection - IK
295 mm
5
5 kg IK 09
200 mm
10
5 kg
6
Completely protected against dust
8
15 cm mini
IK 10 1m
D
The dangerous parts cannot be touched when introducing a wire
m
5
Protected against dust (no harmful deposit)
Protected against prolonged effects of immersion under presure
400 mm
20
(1) A product previously classed as IP xx-7 can be assumed to fulfill the conditions of an IP xx - IK 08
This table can be used to ascertain the resistance of a product to an impact given in Joules from the IK code (graduated from 00 to 10). It can also be used to ascertain the correspondence with the old IP code 3rd digit and the corresponding external “Ag” conditions.
The contents of the Protection Classifications charts are for guidance only. If you have any doubt as to the interpretation of the information contained therein, please refer either to the standard itself or contact Legrand.
Health and Safety at Work, etc. Act. 1974 Statement to Purchasers and Prospective Purchasers 1. Section 6 of this Act provides that manufacturers, designers, importers or suppliers of articles for use at work have a duty to ensure so far as is reasonably practical, that the article will be safe and without risk to health when properly used. An article is not regarded as being ‘properly used’ if it is used without regard to any relevant information or advice relating to its use made available by the manufacturer, designer, importer or supplier. 2. With regard to these provisions the following is given as a guide to the information which is readily available to you. This information relates to those products detailed in our catalogue(s) or associated literature or may be obtained by specific request to the Company. 3. All products should be installed and maintained in accordance with good engineering practice and relevant British or
other applicable standards, regulations for the installation of equipment by the Institute of Electrical Engineers or any other applicable Codes of Practice.
For information concerning wiring device standards outside the UK contact : BSI Customer Services 09:00 to 17:00 – Monday to Friday Tel : +44 (0) 20 8996 9001 Fax : +44 (0) 20 8996 7001 Email : cservices@bsi-global.com
Health and Safety at Work Act The Electricity at Work Regulations, 1989 1. All installations and maintenance should be carried out within the provision of the above Act and by persons so qualified as defined in the Act.
marking appears on electrical or electronic products from Legrand and enables the circulation of goods outside the UK.
2. Information and advice on the suitability of our products can be obtained from Legrand Electric Limited on specific request.
Conditions of sale Please consult our current price list In accordance with its policy of continuous improvement the Company reserves the right to change specifications and designs without notice. All illustrations, descriptions, dimensions and weights in this catalogue are for guidance and cannot be held binding on the Company.
128
RCP resin busbar is the latest addition to the Zucchini range With an ingress protection rating of IP68 and ranging from 630 A to 6300 A, RCP is ideal for the distribution of high power energy in external environments. RCP is manufactured with either aluminium or copper conductors which are completely embedded
quality through to the core Legrand transformers are renowned for quality. Manufactured within a state-of-the-art production facility with attention to detail being paramount, each transformer undergoes rigorous testing prior to despatch.
Legrand has many years experience in the production of dry transformers cast under vacuum in epoxy resin up to 36 kV and has recently launched a new range of ‘GreenT.HE’ high efficiency transformers which conform to IEC 60076-11 and EU regulation 548/2014.
in an epoxy resin, that provides mechanical strength and electrical insulation. RCP resin busbar has good performance in fire conditions and exceeds the requirements stipulated in IEC 60331-1 : 2009 for continuity of service in the event of fire.
CONTACT DETAILS Quotations and Technical Support: Legrand Electric Ltd. Great King Street North, Birmingham, B19 2LF Tel: +44 (0) 370 608 9020 Fax: +44 (0) 345 600 6760 E-mail: powersales.uk@legrand.co.uk Customer Services: Legrand Electric Ltd. No. 1 Industrial Estate Medmonsley Road, Consett County Durham, DH8 6SR Tel: +44 (0) 345 605 4333 Fax: +44 (0) 345 600 6366 E-mail: powersales.uk@legrand.co.uk Republic of Ireland: Tel: 01 295 9673 Fax: 01 295 4671 E-mail: powersales.uk@legrand.co.uk
FOLLOW US AT www.legrand.co.uk www.legrand.ie www.youtube.com/legrandtvuk www.voltimum.co.uk www.voltimum.ie www.twitter.com/legranduk
Head office (UK and Ireland): Legrand Electric Limited Great King Street North, Birmingham, B19 2LF Tel: +44 (0) 370 608 9000 Fax: +44 (0) 370 608 9004 Website: www.legrand.co.uk
In accordance with its policy of continuous improvement, the Company reserves the right to change specifications and designs without notice. All illustrations, descriptions, dimensions and weights in this catalogue are for guidance and cannot be held binding on the Company. All contents and design presentation included in this publication are Š Legrand Electric Limited. All rights reserved. 2018
This document is printed on sustainably sourced paper. Please recycle.
The Legrand logo is a registered trademark of the Legrand group of companies.
999556 Zucchini busbar product guide 12/2018.3K
www.linkedin.com/ company/legranduk