POWERING THE WORKPLACE PRODUCT GUIDE

POWERED BY SPECIALISTS


Global strength built on local knowledge Legrand is the global specialist in electrical and digital building infrastructures. Innovation is the driving force behind its development. With an increasing investment in research and development (circa 5% of sales) and more than 4,000 active patents, the Legrand Group is focused on maintaining a high rate of new product launches that present innovative solutions to the market.

CORPORATE SOCIAL RESPONSIBILITY

LEGRAND’S POWER DISTRIBUTION BUSINESS UNIT

Legrand’s CSR roadmap is a natural extension to the governance and sustainable development approach in which the company has been engaged for many years. The CSR roadmap firmly asserts Legrand’s ongoing commitment to sustainable development.

From Zucchini transformers, through high power distribution and rising main busbar to Electrak powertrack, desk modules and lighting control, Legrand’s power distribution business unit provides market leading solutions to the increasing demands of today’s buildings.

Respect human rights and communities Ensure health, safety and well-being Develop skills Promote equal opportunity and diversity

Provide sustainable solutions Ensure sustainable procurement Act ethically

Mitigate climate change Innovate for the circular economy Prevent pollution


POWERTRACK Overview Ordering information Technical information

6 8 18

FLOOR BOXES

CONTENTS

Electrak, part of the Legrand Group in the UK, is a leading manufacturer of power distribution and lighting control solutions. It's powertrack, floor boxes and grommets, desk modules and lighting control ranges are installed in high specification offices around the world.

Overview 24 Ordering information 26 Technical information 33

FLOOR GROMMETS

Overview 34 Ordering information 36 Technical information 37

INTERSOC-R

Overview 38 Ordering information 42 Technical information 44

ON-DESK

Overview 48 Ordering information 52 Technical information 56

IN-DESK Overview 58 Ordering information 60 Technical information 61

BUSCOM TRUNKING Overview Ordering information Technical information

62 64 68 1


ELECTRAK

ÂŽ

the specialist in power distribution throughout the

workplace

Electrak, a brand of the Legrand Group in the UK, is a leading name in power distribution and lighting control solutions. Electrak busbar systems, floor boxes, floor grommets, desk modules and lighting control ranges are installed in high specification offices around the world.

2


Powering the

workplace UNDERFLOOR POWER Electrak’s powertrack system is perfect for supplying underfloor power in cavity floor installations. With minimal parts, push-fit assembly and a complementary range of floor boxes, this flexible, easy-to-install system can be reconfigured as office layouts evolve.

POWERTRACK See page 6

CAVITY FLOOR BOXES See page 24

WORKSTATION POWER Electrak’s access grommets provide the gateway for power to feed from the underfloor powertrack network to the workstation, where all desk power requirements are met with our new range of desk modules, Intersoc-R, On-desk and In-desk.

FLOOR GROMMETS See page 34

INTERSOC-R See page 38

ON-DESK & IN-DESK See pages 48 & 58

FULLY ADDRESSABLE LIGHTING CONTROL Designed to work in harmony with Buscom trunking, Lightrak lighting control offers high-end sophistication with unbeatable flexibility and speed of installation.

BUSCOM power and data backbone See page 62

LIGHTRAK lighting control system Visit: www.legrand.co.uk

3


ELECTRAK

ÂŽ

UK manufacturing

Global recognition

OVER 30 YEARS' EXPERIENCE Legrand’s cost-effective Electrak systems have been designed and manufactured to distribute power and data reliably and safely throughout the workplace. The original underfloor busbar system, invented by Electrak in the 1980s, sets the benchmark for flexible power distribution.

INDUSTRY EXPERTS As part of its ongoing commitment to research and development, Legrand continually evolves its product ranges to ensure it develops the best and most innovative solutions available on the market. Legrand takes pride in its enviable reputation for market leading customer service, industry knowledge and product expertise. 4


TRUSTED

THROUGHOUT THE UK AND ACROSS THE WORLD

UNITED KINGDOM

MIDDLE EAST & INDIA

ASIA PACIFIC

n

Morgan Stanley, Canary Wharf

n

ADMA-OPCO HQ, Dubai

n

Media City, Manchester

n

Internet City, Dubai

n

JP Morgan, Canary Wharf

n

Burjuman Centre, Dubai

n

RBS, Edinburgh

n

ADIC/Al Bahr Towers, Abu Dhabi

Bridgewater Place, Leeds

n

Al Dar HQ, Abu Dhabi

n

n

Network Rail, Nationwide

n

Central Bank of Kuwait

n

n n

Swiss Re, City of London

n

Ministry of Education, Kuwait

n

Amazon, Swansea

n

PIFFS Aridya, Kuwait

UBS Bank, IFC II, Hong Kong

n

n

Heathrow Airport, London

n

PAAET, Kuwait

JP Morgan, Hong Kong

n

n

n

Snow Hill, Birmingham

n

Qatar News Agency

n

Barclays Capital, Canary Wharf

n

Barclays, Chennai, India

n

n

Temple Back, Bristol

n

Barclays, Pune, India

n

n

Barclays, Andheri, India

n

Barclays, Mumbai, India

n

Standard Chartered Bank, City of London

n

London Underground

n

BBC, White City

RBS, Delhi, India

n

n

n

Mann Island, Liverpool

Fidelity, Delhi, India

QUALITY ASSURED UK MANUFACTURING With its Electrak ranges manufactured from its UK base situated in the North East of England, Legrand can provide a rapid production response and adapt to ever-changing project demands. Having total production control also helps ensure our quality meets the highest standards.

n

n

n

n n

Deutsche Bank, ICC I, Hong Kong Customs Headquarters, North Point, Hong Kong Citi Bank Tower, Hong Kong Macquarie Bank, IFC I, Hong Kong

Nomura Bank, Marina Bay, Singapore Credit Suisse, Singapore ABN Amro, One Raffles Quay, Singapore RBS, One George Street, Singapore Barclays Capital, Shanghai Standard Chartered Bank, Shanghai

BUILDING INFORMATION MODELLING As part of Legrand’s ongoing commitment to supporting construction, we have integrated a number of ranges into the BIM environment to assist all areas of project activity, from design and construction through to facilities management and beyond. Autodesk Revit files are now available for Electrak powertrack, floor boxes and Buscom trunking. Download Revit files at: www.legrand.co.uk

5


POWERTRACK adaptable, reliable adaptable, reliable

underfloor power 6


THE INDUSTRY STANDARD IN UNDERFLOOR POWER Electrak powertrack / underfloor busbar is perfect for cavity floor installations. With minimal parts, push-fit assembly and a complementary range of floor boxes and grommets, this flexible, easy-to-install system can be reconfigured as office layouts evolve. The system consists of continuous lengths of track which are fed via a feed unit and can be installed in floor voids as low as 48mm.

n n

n

n

n

n

63 A rated, IP 40 protection Available in five versions: single phase, clean earth, dual circuit, three phase and auxiliary earth inned busbar version available for T use within Abu Dhabi (see page 15) Available in 1.2m, 1.8m, 2.4m and 3.6m lengths Tap-off outlets are located at every 300 or 600mm pitch Floor mountable (stand-off brackets also available)

Integral track connector plugs into feed unit

Lengths simply push-fit together

Integral fixing brackets for rapid installation

Tap-offs plug into shuttered socket outlets and lock onto track body 7


Electrak® powertrack / underfloor busbar system selection chart

Description

Length (m)

Track lengths with 300 mm socket centres 4 outlets

1·2

6 outlets

1·8

8 outlets

2·4

12 outlets

3·6

Track feeds –

Excluding cables and conduit

–

Flexible metal conduit

1·2

Flexible metal conduit

2·4

Standard tap-off / auxiliary earth tap-off 32 A unfused 16 mm Ø L, N, PE 13 A fused 16 mm Ø L, N, PE 13 A 543·7 fused 16 mm Ø L, N, PE

3 5 3 5 3 5

Low noise / clean earth tap-off 32 A unfused 16 mm Ø CE, L, N, PE 13 A fused 16 mm Ø CE, L, N, PE 13 A 543·7 fused 16 mm Ø CE, L, N, PE

3 5 3 5 3 5

Dual circuit tap-off 3 32 A unfused 20 mm Ø CE, L1, N1 L2, N2, PE 5 3 phase tap-off 32 A 415 V 3 phase 20 mm Ø L1, L2, L3, N, PE 32 A L1 unfused reconfigurable live pin 16 mm Ø L1, N, PE 32 A L2 unfused reconfigurable live pin 16 mm Ø L2, N, PE 32 A L3 unfused reconfigurable live pin 16 mm Ø L3, N, PE

Key code / Busbar arrangement

8

3 5 3 5 3 5 3 5


ELECTRAK 24 Standard system (white)

ELECTRAK 25 Low noise / clean earth system (green)

ELECTRAK 26 Dual circuit system (dark green)

ELECTRAK 27 3 phase system (grey)

ELECTRAK 28 Auxiliary earth system (red)

DA1123

JA2123

KA3123

NA4123

YA5123

DA1183

JA2183

KA3183

NA4183

YA5183

DA1243

JA2243

KA3243

NA4243

YA5243

DA1363

JA2363

KA3363

NA4363

YA5363

DF1010

JF2010

KF3010

NF4010

YF5010

DW1000

JW2000

KW3000

NW4000

YW5000

DW1010

JW2010

KW3010

NW4010

YW5010

DW1020

JW2020

KW3020

NW4020

YW5020

DP1332

–

DP1332

–

YP5332

DP1532

–

DP1532

–

YP5532

DP1313

–

DP1313

–

YP5313

DP1513

–

DP1513

–

YP5513

DP1327

–

DP1327

–

YP5327

DP1527

–

DP1527

–

YP5527

–

JP2332

JP2332

–

–

–

JP2532

JP2532

–

–

–

JP2313

JP2313

–

–

–

JP2513

JP2513

–

–

–

JP2327

JP2327

–

–

–

JP2527

JP2527

–

–

–

–

KP3328

–

–

–

–

KP3528

–

–

– – – – – – – –

– – – – – – – –

– – – – – – – –

NZ4331 NZ4531 NP43321 NP45321 NP43021 NP45021 NP43031 NP45031

– – – – – – – –

PE

N2 L2

PE CE N1 L1

PE CE N1 L1 N2 L2

PE N L1 L2 L3

PE N1 L1

1 : All NP tap-offs are reconfigurable between L1, L2 or L3 for 3 phase track

9


Electrak® 24 powertrack / underfloor busbar system standard system (white)

DF1010

- - -/

---

DW1010

DA1123

DP1332

Selection charts p. 8-9 Dimensions and technical information p. 18-23 Approved to ASTA Standard 138 and ISO 9001 : 2015 Conforms to BS EN 61534-22 : 2014. Fully complies with the requirements of BS 7671 : 2018 A compact system that can be installed in floor voids as low as 48 mm

Pack

Cat. Nos.

Track system components

Electrak 24 standard track lengths

Tap-off length is determined by the cable and not the conduit length, e.g. a 3 m tap-off has 3 m of cable and 2·6 m of flexible metal conduit1 Tap-off units in excess of 3 m should only be used if they contain a fuse or if the powertrack is protected by a protective device not exceeding 32 A

Track lengths fit together using the integral connectors on each length Track lengths should always be secured using the integral floor fixing brackets 300 mm socket centres 1 DA1123 1·2 m, 4 outlets, 2 floor fixing brackets 1 DA1183 1·8 m, 6 outlets, 2 floor fixing brackets 1 DA1243 2·4 m, 8 outlets, 2 floor fixing brackets 1 DA1363 3·6 m, 12 outlets, 3 floor fixing brackets

1

Track feed unit

DF1010 With one 25 mm diameter hole suitable for MICC, armoured cables or single core cables in conduit

Flexible interlinks

Can be used to overcome obstructions or as corners where required 1 DW1000 Excluding cables and conduit 1 DW1010 1·2 m flexible metal conduit 1 DW1020 2·4 m flexible metal conduit Special fixing brackets Required when track is raised off surface level Brackets raise track by 21 mm and should be spaced 600 mm apart 1 DZ1210 For fitting under track body and track feed 1 DZ1230 For fitting under integral track connectors

Pack

Cat. Nos. Tap-off

units

32 A unfused - 543·7 high integrity

16 mm Ø‚ L, N, PE 1 DP1332 3 m 1 DP1532 5 m

13 A fused - 543·7 high integrity

16 mm Ø‚ L, N, PE 1 DP1327 3 m 1 DP1527 5 m

13 A fused

16 mm Ø‚ L, N, PE 1 DP1313 3 m 1 DP1513 5 m

Tap-off units specifically for the U.A.E.

To meet the local requirements, these tap-offs contain silver-flashed blades, larger 20 mm Ø conduits and minimum 4 mm2 conductors

32 A unfused - 543·7 high integrity

L (red), N (black), PE (green/yellow) 1 DP1332R 3 m U.A.E. 1 DP1532R 5 m U.A.E.

13 A fused - 543·7 high integrity

L (red), N (black), PE (green/yellow) 1 DP1314R 3 m U.A.E. 1 DP1514R 5 m U.A.E.

1 : Tap-offs are supplied as standard with flexible metal conduit For alternative wiring solutions, contact us on +44 (0) 370 608 9020

10


Electrak® 25 powertrack / underfloor busbar system low noise / ­­clean earth system (green)

JF2010

- - -/

---

JW2010

JA2123

JP2332

Selection charts p. 8-9 Dimensions and technical information p. 18-23 Approved to ASTA Standard 138 and ISO 9001 : 2015 Conforms to BS EN 61534-22 : 2014. Fully complies with the requirements of BS 7671 : 2018 A compact system that can be installed in floor voids as low as 48 mm

Pack

Cat. Nos.

Track system components

Electrak 25 low noise / clean earth track lengths

Tap-off length is determined by the cable and not the conduit length, e.g. a 3 m tap-off has 3 m of cable and 2·6 m of flexible metal conduit1 Tap-off units in excess of 3 m should only be used if they contain a fuse or if the powertrack is protected by a protective device not exceeding 32 A

Track lengths fit together using the integral connectors on each length Track lengths should always be secured using the integral floor fixing brackets 300 mm socket centres 1 JA2123 1·2 m, 4 outlets, 2 floor fixing brackets 1 JA2183 1·8 m, 6 outlets, 2 floor fixing brackets 1 JA2243 2·4 m, 8 outlets, 2 floor fixing brackets 1 JA2363 3·6 m, 12 outlets, 3 floor fixing brackets

1

Track feed unit

JF2010 With one 25 mm diameter hole suitable for MICC, armoured cables or single core cables in conduit

Flexible interlinks

Can be used to overcome obstructions or as corners where required 1 JW2000 Excluding cables and conduit 1 JW2010 1·2 m flexible metal conduit 1 JW2020 2·4 m flexible metal conduit

Pack

Cat. Nos. Tap-off

units

32 A unfused - 543·7 high integrity

16 mm Ø‚ CE, L, N, PE 1 JP2332 3 m 1 JP2532 5 m

13 A fused - 543·7 high integrity

16 mm Ø‚ CE, L, N, PE 1 JP2327 3 m 1 JP2527 5 m

13 A fused

16 mm Ø‚ CE, L, N, PE 1 JP2313 3 m 1 JP2513 5 m

Special fixing brackets Required when track is raised off surface level Brackets raise track by 21 mm and should be spaced 600 mm apart 1 DZ1210 For fitting under track body and track feed 1 DZ1230 For fitting under integral track connectors

1 : Tap-offs are supplied as standard with flexible metal conduit For alternative wiring solutions, contact us on +44 (0) 370 608 9020

11


Electrak® 26 powertrack / underfloor busbar system dual circuit system (dark green)

KF3010

- - -/

---

KW3010

KA3123

KP3328

Selection charts p. 8-9 Dimensions and technical information p. 18-23 Approved to ASTA Standard 138 and ISO 9001 : 2015 Conforms to BS EN 61534-22 : 2014. Fully complies with the requirements of BS 7671 : 2018 A compact system that can be installed in floor voids as low as 48 mm

Pack

Cat. Nos.

Track system components

The dual powertrack system has both standard and low noise / clean earth systems incorporated

Electrak 26 dual circuit track lengths

Track lengths fit together using the integral connectors on each length Track lengths should always be secured using the integral floor fixing brackets 300 mm socket centres 1 KA3123 1·2 m, 4 outlets, 2 floor fixing brackets 1 KA3183 1·8 m, 6 outlets, 2 floor fixing brackets 1 KA3243 2·4 m, 8 outlets, 2 floor fixing brackets 1 KA3363 3·6 m, 12 outlets, 3 floor fixing brackets

1

Track feed unit

KF3010 With two 25 mm diameter holes suitable for MICC, armoured cables or single core cables in conduit

Flexible interlinks

Can be used to overcome obstructions or as corners where required 1 KW3000 Excluding cables and conduit 1 KW3010 1·2 m flexible metal conduit 1 KW3020 2·4 m flexible metal conduit Special fixing brackets Required when track is raised off surface level Brackets raise track by 21 mm and should be spaced 600 mm apart 1 DZ1210 For fitting under track body and track feed 1 DZ1230 For fitting under integral track connectors

Pack

Cat. Nos. Tap-off

units

Tap-off length is determined by the cable and not the conduit length, e.g. a 3 m tap-off has 3 m of cable and 2·6 m of flexible metal conduit1 Tap-off units in excess of 3 m should only be used if they contain a fuse or if the powertrack is protected by a protective device not exceeding 32 A

Standard 32 A unfused - 543·7 high integrity

16 mm Ø‚ L, N, PE 1 DP1332 3 m 1 DP1532 5 m

Standard 13 A fused - 543·7 high integrity

16 mm Ø‚ L, N, PE 1 DP1327 3 m 1 DP1527 5 m

Standard 13 A fused

16 mm Ø‚ L, N, PE 1 DP1313 3 m 1 DP1513 5 m Low noise / clean earth 32 A unfused 543·7 high integrity 16 mm Ø‚ CE, L, N, PE 1 JP2332 3 m 1 JP2532 5 m Low noise / clean earth 13 A fused 543·7 high integrity 16 mm Ø‚ CE, L, N, PE 1 JP2327 3 m 1 JP2527 5 m

Low noise / clean earth 13 A fused

16 mm Ø‚ CE, L, N, PE 1 JP2313 3 m 1 JP2513 5 m

Dual circuit 32 A unfused - 543·7 high integrity

20 mm Ø‚ CE, L1, N1, L2, N2,PE 1 KP3328 3 m 1 KP3528 5 m

1 : Tap-offs are supplied as standard with flexible metal conduit For alternative wiring solutions, contact us on +44 (0) 370 608 9020

12


Electrak® 27 powertrack / underfloor busbar system 3 phase system (grey)

NF4010

- - -/

---

NW4010

NA4123

NZ4331

Selection charts p. 8-9 Dimensions and technical information p. 18-23 Approved to ASTA Standard 138 and ISO 9001 : 2015 Conforms to BS EN 61534-22 : 2014. Fully complies with the requirements of BS 7671 : 2018 A compact system that can be installed in floor voids as low as 48 mm

Pack

Cat. Nos.

Track system components

Pack

Electrak 27 3 phase track lengths

Tap-off length is determined by the cable and not the conduit length, e.g. a 3 m tap-off has 3 m of cable and 2·6 m of flexible metal conduit1 Tap-off units in excess of 3 m should only be used if they contain a fuse or if the powertrack is protected by a protective device not exceeding 32 A

Track lengths fit together using the integral connectors on each length Track lengths should always be secured using the integral floor fixing brackets 300 mm socket centres 1 NA4123 1·2 m, 4 outlets, 2 floor fixing brackets 1 NA4183 1·8 m, 6 outlets, 2 floor fixing brackets 1 NA4243 2·4 m, 8 outlets, 2 floor fixing brackets 1 NA4363 3·6 m, 12 outlets, 3 floor fixing brackets

1

Track feed unit

NF4010 With one 25 mm diameter hole suitable for MICC, armoured cables or single core cables in conduit

Flexible interlinks

Can be used to overcome obstructions or as corners where required 1 NW4000 Excluding cables and conduit 1 NW4010 1·2 m flexible metal conduit 1 NW4020 2·4 m flexible metal conduit Special fixing brackets Required when track is raised off surface level Brackets raise track by 21 mm and should be spaced 600 mm apart 1 DZ1210 For fitting under track body and track feed 1 DZ1230 For fitting under integral track connectors

Cat. Nos.

Tap-off units

32 A 415 V 3 phase - 543·7 high integrity

20 mm Ø‚ L1, L2, L3, N, PE 1 NZ4331 3 m 1 NZ4531 5 m

32 A L12 unfused - 543·7 high integrity

Reconfigurable live pin 16 mm Ø‚ L, N, PE 1 NP4332 3 m 1 NP4532 5 m

32 A L22 unfused - 543·7 high integrity

Reconfigurable live pin 16 mm Ø‚ L, N, PE 1 NP4302 3 m 1 NP4502 5 m

32 A L32 unfused - 543·7 high integrity

Reconfigurable live pin 16 mm Ø‚ L, N, PE 1 NP4303 3 m 1 NP4503 5 m

Tap-off units specifically for the U.A.E.

To meet the local requirements, these tap-offs contain silver-flashed blades, larger 20 mm Ø conduits, minimum 4 mm2 conductors and use RYB colour coding for the conductors

1 1 1 1 1 1

32 A unfused - 543·7 high integrity

NP4332R 3 m L1 U.A.E. (R) NP4532R 5 m L1 U.A.E. (R) NP4302Y 3 m L2 U.A.E. (Y) NP4502Y 5 m L2 U.A.E. (Y) NP4303B 3 m L3 U.A.E. (B) NP4503B 5 m L3 U.A.E. (B)

1 : Tap-offs are supplied as standard with flexible metal conduit For alternative wiring solutions, contact us on +44 (0) 370 608 9020 2 : All NP tap-offs are reconfigurable between L1, L2, or L3 for 3 phase track

13


Electrak® 28 powertrack / underfloor busbar system auxiliary earth system (red)

YF5010

- - -/

---

YW5010

YA5123

YP5332

Selection charts p. 8-9 Dimensions and technical information p. 18-23 Approved to ASTA Standard 138 and ISO 9001 : 2015 Conforms to BS EN 61534-22 : 2014. Fully complies with the requirements of BS 7671 : 2018 A compact system that can be installed in floor voids as low as 48 mm

Pack

Cat. Nos.

Track system components

Electrak 28 auxiliary earth track lengths

Tap-off length is determined by the cable and not the conduit length, e.g. a 3 m tap-off has 3 m of cable and 2·6 m of flexible metal conduit1 Tap-off units in excess of 3 m should only be used if they contain a fuse or if the powertrack is protected by a protective device not exceeding 32 A

Track lengths fit together using the integral connectors on each length Track lengths should always be secured using the integral floor fixing brackets 300 mm socket centres 1 YA5123 1·2 m, 4 outlets, 2 floor fixing brackets 1 YA5183 1·8 m, 6 outlets, 2 floor fixing brackets 1 YA5243 2·4 m, 8 outlets, 2 floor fixing brackets 1 YA5363 3·6 m, 12 outlets, 3 floor fixing brackets

1

Track feed unit

YF5010 With one 25 mm diameter hole suitable for MICC, armoured cables or single core cables in conduit

Flexible interlinks

Can be used to overcome obstructions or as corners where required 1 YW5000 Excluding cables and conduit 1 YW5010 1·2 m flexible metal conduit 1 YW5020 2·4 m flexible metal conduit

Pack

Cat. Nos. Tap-off

units

32 A unfused - 543·7 high integrity

16 mm Ø‚ L, N, PE 1 YP5332 3 m 1 YP5532 5 m

13 A fused - 543·7 high integrity

16 mm Ø‚ L, N, PE 1 YP5327 3 m 1 YP5527 5 m

13 A fused

16 mm Ø‚ L, N, PE 1 YP5313 3 m 1 YP5513 5 m

Special fixing brackets Required when track is raised off surface level Brackets raise track by 21 mm and should be spaced 600 mm apart 1 DZ1210 For fitting under track body and track feed 1 DZ1230 For fitting under integral track connectors

1 : Tap-offs are supplied as standard with flexible metal conduit For alternative wiring solutions, contact us on +44 (0) 370 608 9020

14


Electrak

tinned powertrack... Designed to meet local standards

As a specific requirement for use within Abu Dhabi, Legrand has developed a ‘tinned’ busbar which has been designed in line with the guidance for busways outlined by the Abu Dhabi Distribution Company (ADDC), as detailed below.

Guideline For Design, Testing and Installation Of Busways GL.GN.01. Issued by: Abu Dhabi Distribution Co. Low Voltage Switchgear Committee Issue: 2, Revision: 1, effective 01/02/2012 16. Lighting & Small Power Busways & Modular Wiring Lighting & Power Socket bus duct and modular wiring are considered part of building wiring and regulated by the Electricity Wiring Regulation issued by RSB. It shall comply with respective specifications under the Wiring regulation. ADDC LVSGC approves these methods in principle provided that the RSB set aspects are incorporated (like tinning of copper, colour coding etc.).

Electrak 28R tinned tap-offs

Electrak 28R tinned busbar connectors

Appendix 8. Colour identification for cables Conductor

Colour

Non-flexible fixed wiring and all 3 phase cables: Phase 1

Red

Copyright Abu Dhabi Distribution Co.

Phase 2

Yellow

Developed to meet the ADDC requirements for busways, these specially designed ranges see all busbars tinned along their entire length, and all busbar connectors and tap-off blades plated.

Phase 3

Blue

Neutral

Black

Earth conductors

Green / yellow

Guideline For Design, Testing and Installation Of Busways GL.GN.01

Approved to ASTA standard 138 and designed to be in accordance with the requirements of BS EN 61439-6 : 2011 and BS EN 61534-22: 2014 (IEC 61534: 2009).

The Electrical Wiring Regulations 2007 Issued by: The Regulation and Supervision Bureau for the Water, Wastewater and Electricity Sector in the Emirate of Abu Dhabi. Revision 1, January 2009 7.7 Busways, bus ducts and busbar risers 7.7.6 Busways, bus ducts and busbar risers shall have neutral conductors of equal size to the phase conductors and shall have a dedicated Earth Conductor. The use of the metal casing as an earth conductor permitted only for Earth Leakage Protected Installations, and with the prior approval of the Distribution Company.

To meet the local regulations, tap-offs designed for sale within this region are supplied with the following cable colours: Within any single phase system (e.g. Electrak 25R or Electrak 28R) - red (L), black (N) and green/yellow (E). Specifically within the 3 phase Electrak 27 system - L1 tapoffs are red (L), black (N) and green/yellow (E); L2 tap-offs are yellow (L), black (N) and green/yellow (E); L3 tap-offs are blue (L), black (N) and green/yellow (E). Appendix 9. Capacity of conduits and trunking Conduit (mm2)

Diameter of Conduit (mm2) 20

25

32

Maximum number of conductors

1.5

7

12

-

2.5

5

9

12

4.0

3

6

9

The tap-offs contain a maximum of 2 x 4mm2 conductors (excluding earths) housed in a 20mm ø metal flexible conduit.

The Electrical Wiring Regulations 2007 Copyright The Regulation and Supervision Bureau (RSB)

The Electrak powertrack system uses equal size tinned copper busbars for live, neutral and earth conductors to meet with the requirements of The Regulation and Supervision Bureau of the Water, Wastewater and Electricity Sector in the Emirate of Abu Dhabi.

NOTE: When designing installation in

regions with higher ambient temperatures than 35ºC, de-rating factors may need to be applied. Please refer to the table on page 22 for details.

15


Electrak® 25R tinned powertrack / underfloor busbar system low noise / clean earth system (green)

JF2010R

- - -/

---

JW2010R

JA2123R

JP2332R

Dimensions and technical information p. 18-23 Approved to ASTA Standard 138 and ISO 9001 : 2015 Conforms to BS EN 61534-22 : 2014. Fully complies with the requirements of BS 7671 : 2018 A compact system that can be installed in floor voids as low as 48 mm

Pack

Cat. Nos.

Busbar system components

63 A low noise / clean earth busbar lengths

Tap-off length is determined by the cable and not the conduit length, e.g. a 3 m tap-off has 3 m of cable and 2·6 m of flexible metal conduit1 Tap-off units in excess of 3 m should only be used if they contain a fuse or if the busbar run is protected by a protective device not exceeding 32 A

Busbar lengths fit together using the integral connectors on each length Lengths should always be secured using the integral floor fixing brackets 300 mm socket centres 1 JA2123R 1·2 m, 4 outlets, 2 floor fixing brackets 1 JA2183R 1·8 m, 6 outlets, 2 floor fixing brackets 1 JA2243R 2·4 m, 8 outlets, 2 floor fixing brackets 1 JA2363R 3·6 m, 12 outlets, 3 floor fixing brackets

1

Feed unit

JF2010R With one 25 mm diameter hole suitable for MICC, armoured cables or single core cables in conduit

Flexible interlinks

Can be used to overcome obstructions or as corners where required 1 JW2000R Excluding cables and conduit 1 JW2010R 1·2 m flexible metal conduit 1 JW2020R 2·4 m flexible metal conduit

Pack

Cat. Nos. Tap-off

units

32 A unfused - 543·7 high integrity

20 mm Ø‚ CE, L, N, PE (4 mm2) 1 JP2332R 3 m 1 JP2532R 5 m

13 A fused - 543·7 high integrity

20 mm Ø‚ CE, L, N, PE (4 mm2) 1 JP2314R 3 m 1 JP2514R 5 m

Special fixing brackets Required when busbar is raised off surface level Brackets raise the system by 21 mm and should be spaced 600 mm apart 1 DZ1210 For fitting under lengths and feed units 1 DZ1230 For fitting under integral connectors

1 : Tap-offs are supplied as standard with flexible metal conduit For alternative wiring solutions, contact us on +44 (0) 370 608 9020

16


Electrak® 28R tinned powertrack / underfloor busbar system auxiliary earth system (red)

YF5010R

- - -/

---

YW5010R

YA5123R

YP5332R

Dimensions and technical information p. 18-23 Approved to ASTA Standard 138 and ISO 9001 : 2015 Conforms to BS EN 61534-22 : 2014. Fully complies with the requirements of BS 7671 : 2018 A compact system that can be installed in floor voids as low as 48 mm

Pack

Cat. Nos.

Busbar system components

63 A auxiliary earth busbar lengths

Tap-off length is determined by the cable and not the conduit length, e.g. a 3 m tap-off has 3 m of cable and 2·6 m of flexible metal conduit1 Tap-off units in excess of 3 m should only be used if they contain a fuse or if the busbar run is protected by a protective device not exceeding 32 A

Busbar lengths fit together using the integral connectors on each length Lengths should always be secured using the integral floor fixing brackets 300 mm socket centres 1 YA5123R 1·2 m, 4 outlets, 2 floor fixing brackets 1 YA5183R 1·8 m, 6 outlets, 2 floor fixing brackets 1 YA5243R 2·4 m, 8 outlets, 2 floor fixing brackets 1 YA5363R 3·6 m, 12 outlets, 3 floor fixing brackets

1

Feed unit

YF5010R With one 25 mm diameter hole suitable for MICC, armoured cables or single core cables in conduit

Flexible interlinks

Can be used to overcome obstructions or as corners where required 1 YW5000R Excluding cables and conduit 1 YW5010R 1·2 m flexible metal conduit 1 YW5020R 2·4 m flexible metal conduit

Pack

Cat. Nos. Tap-off

units

32 A unfused - 543·7 high integrity

20 mm Ø‚ L, N, PE (4 mm2) 1 YP5332R 3 m 1 YP5532R 5 m

13 A fused - 543·7 high integrity

20 mm Ø‚ L, N, PE (4 mm2) 1 YP5314R 3 m 1 YP5514R 5 m

Special fixing brackets Required when busbar is raised off surface level Brackets raise the system by 21 mm and should be spaced 600 mm apart 1 DZ1210 For fitting under lengths and feed units 1 DZ1230 For fitting under integral connectors

1 : Tap-offs are supplied as standard with flexible metal conduit For alternative wiring solutions, contact us on +44 (0) 370 608 9020

17


Electrak® powertrack / underfloor busbar system design and installation n General installation notes

n Special fixing brackets

Electrak powertrack is a compact system that can be installed in floor voids as low as 48 mm

Electrak special fixing brackets are available to raise the system by 21 mm. Ensure brackets are spaced 600 mm apart and always have support under the integral connectors and feed units. Failure to do so may undermine the integrity of the system

Feed units are provided with one or two 25 mm diameter holes suitable for MICC, armoured cables or single core cables in conduit Track lengths connect together and to feed units using the integral connectors on each length Lengths should always be secured using the integral floor fixing brackets ; three on the 3·6 m length and two on 2·4 m, 1·8 m or 1·2 m lengths

Cat. No. DZ1210 raised off-floor fixing brackets are spaced at 600 mm centres along the busbar run. Also use bottom half of bracket under feed unit and flexible interlink Cat. No. DZ1230 raised off-floor fixing brackets are always used under integral connectors. Busbar is secured to raised brackets using the integral fixing bracket

Access to power is provided along the busbar length by simply plugging tap-off units into shuttered socket outlets. These tap-off units feed all types of conventional floor service outlet boxes or feed workstations directly through the floor via insulated conductors contained in flexible metal or VO rated nylon conduit. When connecting tap-offs directly through the floor via grommet outlets to workstations care must be taken to ensure that the tap-off length is adequate Integral fixing bracket screws to special bracket

The dual system has both standard and low noise / clean earth systems incorporated. As well as dual tap-offs, both standard and low noise / clean earth tap-offs can be plugged into any socket outlet along the busbar length. The dual tap-off incorporates both standard and low noise cables Optimum layout flexibility is achieved by positioning busbar lengths a maximum of 5·2 m apart and 2·5 m from the wall, and by connecting the 3 m tap-off units to floor outlet boxes. This means every part of the floor area can be served. Flexible interlinks can be used to overcome obstructions or used as corners if required

Integral connector

50 mm

185 mm

7 mm Ø

7 mm Ø

99 mm

Cat. No. DZ1210

21 mm to underside and 36 mm to top of busbar length

Cat. No. DZ1230

n Dimensions

75

93

250 46

46 2 x 25 Ø

109

68

118

47

32

15

25 Ø

65

End view A

End view B

92

Integral fixing bracket fixing centres

2·5 m

Example floor layout

feed unit

5·2 m

5·2 m

5·2 m

socket outlet points every 300 or 600 mm along busbar run

All dimensions (mm) are nominal

18

3 m flexible tap-off unit

floor service outlet box

integral connectors


n Product configuration Tap-off connection

Flexible interlink Flexible interlink boxes must be securely fixed inline to surface so no movement can take place after fixing

Depress tap-off side clips and push down Tap-off

Side clip Push down

Interlink feed entry socket. Remove dust cover label

Make sure both tapoff side clips are fully pushed home on both sides of tthe bar

Remove dust cover from end entry socket before use

Screw fix to surface

Feed unit (Cat. No. DF1010) Sub-cabling

Tap-off connection Tap-off metal flexible conduit

Feed unit protective earth terminal and earth bond Protective earth must always be connected via the earth terminal block

Lift lid

20 mm Ø conduit fitting. Tighten back nut securely

Connector terminals

Lift terminal tab to access terminal screws and close after use

25 mm Ø cable conduit fixing hole Close lid and secure with lid fixing screw before power up

Feed unit (Cat. No. JF2010 and JF2010R) Sub-cabling

Tap-off connection Tap-off metal flexible conduit

Feed unit protective earth terminal and earth bond Protective earth must always be connected via the earth terminal block

Lift lid

Connector terminals

20 mm Ø conduit fitting Tighten back nut securely

Lift terminal tab to access terminal screws and close after use Clean earth 25 mm Ø cable conduit fixing hole Close lid and secure with lid fixing screw before power up

All dimensions (mm) are nominal

19


Electrak® powertrack / underfloor busbar system design and installation (continued) n Product configuration (continued) Feed unit (Cat. No. KF3010) Sub-cabling

Dual tap-off connection (dark green) Tap-off metal flexible conduit

Lift terminal tab to access terminal screws and close after use

Protective earth must always be connected via the earth terminal block

Feed unit protective earth terminal and earth bond

Lift lid

20 mm Ø conduit fitting Tighten back nut securely

Connections L1, N1, CE = low noise L2, N2, PE = standard

Connections L1, N1, CE = low noise L2, N2, PE = standard Connector terminals Clean earth 2 x 25 mm Ø cable conduit fixing hole

Close lid and secure with lid fixing screw before power up

3 phase tap-off connection

Feed unit (Cat. No. NF4010) Sub-cabling

Tap-off metal flexible conduit Feed unit protective earth terminal and earth bond Protective earth must always be connected via the earth terminal block

Lift lid

20 mm Ø conduit fitting Tighten back nut securely

Connector terminals

Lift terminal tab to access terminal screws and close after use

25 mm Ø cable conduit fixing hole Close lid and secure with lid fixing screw before power up

Tap-off connection

Feed unit (Cat. No. YF5010 and YF5010R) Sub-cabling

Tap-off metal flexible conduit Feed unit protective earth terminal and earth bond Protective earth must always be connected via the earth terminal block

Lift lid

Connector terminals

Lift terminal tab to access terminal screws and close after use

25 mm Ø cable conduit fixing hole Close lid and secure with lid fixing screw before power up

All dimensions (mm) are nominal

20

20 mm Ø conduit fitting Tighten back nut securely


Electrak® powertrack / underfloor busbar system installation (continued)

All integral fixing brackets must be fixed to surface at 1·2 m fixing centres from first bracket on each busbar length

1 Fix feed unit to surface Feed unit

Make chalk line to align busbar lengths

Direction of busbar run

2 Connect busbar length to feed unit Integral connector Busbar length

Remove dust cover Push down

Make sure connector clips are fully pushed home on both sides

Push down

Additional length

Feed unit

3 Connect additional busbar lengths

Remove dust cover before connecting additional lengths

First fixing bracket Pull out fixing bracket lugs and screw fix on both sides

4 Secure busbar lengths to surface Tap-off outlets reusable plastic dust covers 600 mm

600 mm between fixing bracket

MS screws supplied

Integral track fixing bracket

First integral track fixing bracket

Busbar length

Integral connector Feed unit Busbar length

21 mm

All dimensions (mm) are nominal

Track feeds are screw fixed to bottom half of fixing bracket Cat. No. DZ1210

First track integral fixing brackets must be screw fixed to Cat. No. DZ1230 fixing bracket

Cat. No. DZ1230 fixing bracket

Cat. No. DZ1210 fixing bracket fixed at 600 mm centres along busbar length Bracket fixing dimensions to surface 50 mm

185 mm 50 mm Ø

99 mm

fixing brackets

99 mm

5 Raised-off floor

Track run

21


Electrak® powertrack / underfloor busbar system technical data n Earth fault loop impedance

n Standards

Approved to ASTA Standard 138 BS EN 61534-22 : 2014 and IEC 61534-22 : 2014 Manufactured within an approved ISO 9001 : 2015 and ISO 14001 : 2015 facility Assessed Quality Assurance Certificate No. 2029 Electrak powertrack / underfloor busbar fully complies with the requirements of BS 7671 : 2018

BS 7671 : 2018 requires accurate determination of the total earth loop impedance, which must be sufficiently low to allow the protective device to operate within the specified time, which for socket outlets is 0·4 seconds. The values relevant to Electrak powertrack / underfloor busbar for calculating the earth fault loop impedance are shown in the electrical test data table, see opposite

n Durability Electrak systems are superbly designed and extremely robust. They can be expected to stand up to all normal site conditions. Electrak powertrack / underfloor busbar has been short circuit strength tested by ASTA

n Installations with high protective conductor currents

7.1

Resistance to impact

Medium impact – 5J

7.2.2

Connection

Tap-off is intended to be connected/disconnected when the system is energised but without a load connected

7.3

Degree of protection

IP40

7.4

Degree of pollution

Pollution degree 2

All unfused tap-offs comply with Regulation 543·7 without the need for additional earth conductors. Regulation 543·7·1·203 (ii) states “a single copper protective conductor having a cross-sectional area of not less than 4 mm2, complying with the requirements of Regulations 543·2 and 543·3, the protective conductor being enclosed to provide additional protection against mechanical damage, for example, within a flexible conduit” For installations with high protective conductor currents requiring fused tap-offs, a 543·7 compliant tap-off must be used. Normally fused tap-offs incorporate 1·5 mm2 conductors, however in our fused 543·7 tap-offs, the 1·5 mm2 earth conductor is replaced with a 4 mm2 conductor and are therefore compliant with Section 543·7·1·203 (ii)

7.5

Rated impulse withstand voltage

Category III - 4kV

n 32 A tap-off unit

7.101

Type of floor treatment

Dry treatment of floor

7.102

Intended location

Underfloor powertrack system

n Classifications according to BS 61534-22 : 2014

n Ambient temperature rating factors The current carrying capacity for a powertrack / underfloor busbar (In) is affected by the ambient temperature For Electrak powertrack / underfloor busbar the ambient rating factor Ka is equal to 1 for ambient temperatures up to and including 35° C Iz = Ka In Where : Iz = e ffective current carrying capacity for continuous service under particular installation conditions Ka = ambient temperature factor In = nominal current carrying capacity For ambient temperatures exceeding 35° C the values of Ka and Iz are given in the following tables

The 3 m 32 A tap-off unit comprises an unfused tap-off with 2·6 m of flexible metal conduit with integral 4 mm2 LSOH conductors These units are designed to comply with Regulation 543·7·1·203 (ii) of the IET Wiring Regulations by virtue of the following : • maximum length of cable is 3 m • it is factory assembled and fully tested item with cable installed in high quality flexible conduit Fault condition protection for the tap-off assembly and the floor box socket outlets is delivered by the circuit protection device Disconnection time for socket outlets is 0·4 seconds (Regulation 411·3·2·2). The Electrak system meets this requirement Tap-off units in excess of 3 m should only be used if they contain a fuse or the busbar run is protected by a protective device not exceeding 32 A

Powertrack / underfloor busbar system Ambient 20°C 25°C 30°C 35°C 40°C 45°C 50°C Ka 1 0·95 0·85 0·80 Iz 63 A 59 A 53 A 50 A 32 A unfused tap-off (using thermosetting 90°C cables) Ambient 20°C 25°C 30°C 35°C 40°C 45°C 50°C Ka 1 0·95 0·85 0·80 Iz 32 A 30 A 27 A 25 A 13 A fused tap-off (using 2·5 mm2 thermosetting 90°C cables) Ambient 20°C 25°C 30°C 35°C 40°C 45°C 50°C Ka 1 Iz 13 A References : BS 7671 : 2018

All dimensions (mm) are nominal

22


Earth fault loop impedance

Volt drops (live and neutral) Busbars

Cable connector Integral connector 32 A tap-off + 4 mm2 cable Flexible corner assembly + 10 mm2 cable

3·0 mV/A/m 0·4 mV/A 0·4 mV/A 0·4 mV/A 11 mV/A/m 1·5 mV/A 4·0 mV/A/m

Mechanical data

E24 – E28 E28R Number of conductors 3-6 3 Busbar conductor cross sectional area 13 mm2 13 mm2 Housing cross sectional area (copper equivalent) 13 mm2 13 mm2 2 Cable terminal capacity 16 mm 16 mm2 Tap-off cable 32 A 4 mm2 4 mm2 Tap-off cable 13 A fused 1·5 mm2 2·5 mm2 Tap-off conduit, up to 4 conductors 16 mmØ 20 mmØ Tap-off conduit, 5 and 6 conductors 20 mm2 N/A Flexible corner cable (tri-rated, high temperature) 10 mm2 10 mm2 Flexible corner conduit 25 mmØ 25 mmØ IP rating 40 40

Phase busbar Earth busbar Earth housing Earth busbar and housing Cable connector Integral connector 32 A tap-off + 4 mm2 cable Flexible corner assembly + 10 mm2 cable Rated conditional short-circuit current Ambient temperature

1·5 mΩ/m 1·5 mΩ/m 1·1 mΩ/m 0·8 mΩ/m 0·4 mΩ 0·6 mΩ 0·6 mΩ 11 mΩ/m 1·5 mΩ 4·0 mΩ/m 16 KA 25˚C

Electrical test data Rated current

Rated voltage Frequency Conductor resistance - live and neutral Conductor impedance

63 A 230/400 V~ 50 Hz 3·0 mΩ/m 1·5 mΩ/m

Material specifications

Housing - busbar lengths Busbars Busbar insulator

Galvanised steel, natural finish High conductivity copper (Tinned version is electro-tin plated) PTFE

Flame retardant polycarbonate Acetal Flame retardant polycarbonate Copper (Tinned version is plated) Copper (Tinned version is plated) Electro-galvanised steel LSOH to BS EN 50525 Tri-rated to BS 6231 Galvanised steel Brass (Tinned version is plated) Galvanised steel To BS 1362, ASTA approved

Integral connectors / Tap-off outlets Tap-off outlet entry shutter Tap-off housing Integral connector blades Tap-off blades Tap-off/flexible corner conduit, metal Tap-off cable Flexible interlink cable Feed box/flexible interlink boxes Feed connector terminals/earth block Fixing brackets 13 A tap-off, fuse

All dimensions (mm) are nominal

23


FLOOR BOXES choice, flexibility &

easy installation

Raised access floor boxes and slab boxes offer complete versatility. Floor boxes are available pre-wired with powertrack tap-off, or supplied empty (unassembled), with a choice of single or separate compartment bases and three depth options. With a vast selection of power and data plates available, boxes can be tailored to the specific requirements of each office installation. 24

NOTE : Please consult us for different plate options on +44 (0) 370 608 9020. Photos are only illustrative.


Available in 2, 3 and 4 compartments and with a choice of three depths, Electrak floor boxes have been developed with a host of special features:

n

n

n

n

vailable pre-wired with tap-off or supplied A unassembled A wide selection of power and data plates, including RCD options ingle or separate compartment bases for ease of S data cabling Rapid installation and fast ratchet mechanism which adjusts to floor finish thickness

2

1

3

4

6

5

7

Rapid fit /remove mechanism adjusts for flooring thickness Quick-fit, reversible lid for rapid installation Durable ABS trim and lid surround Various RCD protection options available

8

Rapid fit push lock secures base in floor aperture Available pre-wired with tap-off Three depth options: 75mm, 85mm, 110mm Single or separate compartment bases NOTE : Please consult us for different plate options on +44 (0) 370 608 9020. Photos are only illustrative.

25


access floor service outlet and slab mounted floor boxes empty boxes and accessory plates

2 compartment

mm

366

mm

mm

mm

290

4 compartment

230

230

mm 230

To configure boxes as required, select : 1. Box depth 2. Number of compartments required 3. Desired accessory plates

3 compartment

366

mm

100 mm width plates

100 mm width plates

75 mm width plates

Single base – 75 mm depth

CR2001

CR011

CR4001

Single base – 85 mm depth (standard box)

CR2002

CR012

CR4002

Single base – 110 mm depth

CR2003

CR013

CR4003

Separate compartment base – 75 mm depth

CR2004

CR014

CR4004

Separate compartment base – 85 mm depth

CR2005

CR015

CR4005

Separate compartment base – 110 mm depth

CR2006

CR016

CR4006

Empty boxes

Slab boxes

Fix directly onto floor slab (supplied empty)

26

Example

1 compartment

2 compartment

3 compartment

4 compartment

CR5102

CR5202

CR5302

CR5402


2 compartment

Accessory plates

mm

366

mm

mm

mm

290

4 compartment

230

230

mm 230

To configure boxes as required, select : 1. Box depth 2. Number of compartments required 3. Desired accessory plates

3 compartment

366

mm

For 1, 2 and 3 compartment boxes

For 4 compartment boxes

Blank plate

CR020

CR4100

2 gang switched socket outlet

CR022

CR4101

2 gang switched socket outlet, low noise / clean earth

CR023

CR4102

2 gang non-standard switched socket outlet

CR027

CR4103

2 gang unswitched socket outlet

CR029

CR4104

3 gang unswitched socket outlet

CR030

CR4195

3 gang unswitched socket outlet, low noise / clean earth

CR044

CR4118

2 gang RCD socket outlet

CR036

CR4111

2 gang RCD socket outlet, low noise / clean earth

CR043

CR4117

2 gang RCD shallow socket outlet specifically for 75 mm deep floor boxes

CR046

CR4121

2 gang RCD shallow socket outlet low noise / clean earth specifically for 75 mm deep floor boxes

CR053

CR4127

Punched plate for 2 x 1 gang accessories (60·3 mm fixing centres)

CR026

–

Punched plate for 2 gang accessories (120·6 mm fixing centres)

CR028

–

Angled punched plate for 4 x RJ45 sockets (37 mm x 22 mm cut-outs)

CR042

CR4115

2 x LJ2 accessory plate (50 mm fixing centres)

CR031

CR4106

4 x BNC connector plate

CR033

CR4108

4 x Data / telecoms plate (37 mm x 22 mm cut-outs)

CR024

CR4112

6 x Data / telecoms plate (37 mm x 22 mm cut-outs)

CR025

CR4113

Punched plate for 2 x 50 mm x 50 mm Euro Module

CR035

–

Punched plate for 3 x 45 mm x 45 mm Arteor modules

CR070

CR4200

27


access floor pre-wired service outlet boxes and accessory plates Pre-wired service outlet boxes with Electrak tap-offs 1. S elect powertrack tap-off and desired configuration 2. S elect additional accessory plates (if required) Includes 1 x twin switched socket outlet

Includes 2 x twin switched socket outlet

Includes 1 x 2 gang RCD socket outlet

Includes 2 x 2 gang RCD socket outlet

DP1332 - 3 m

CR100

CR102

CR100R

CR102R

DP1532 - 5 m

CR101

CR103

CR101R

CR103R

JP2332 - 3 m

CR110

CR112

CR110R

CR112R

JP2532 - 5 m

CR111

CR113

CR111R

CR113R

YP5332 - 3 m

CR104

CR106

CR104R

CR106R

YP5532 - 5 m

CR105

CR107

CR105R

CR107R

3 compartment

Electrak 24 - standard tap-off

Electrak 25 - low noise / clean earth tap-off

230 mm 366

mm

Electrak 28 - auxiliary earth tap-off

Additional plates for 3 compartment boxes

Blank plate

CR020

2 x LJ2 accessory plate (50 mm fixing centres)

CR031

Punched plate for 2 x 1 gang accessories (60¡3 mm fixing centres)

CR026

4 x BNC connector plate

CR033

Punched plate for 2 gang accessories (120¡6 mm fixing centres)

CR028

4 x Data / telecoms plate (37 mm x 22 mm cut-outs)

CR024

Angled punched plate for 4 x RJ45 sockets (37 mm x 22 mm cut-outs)

CR042

6 x Data / telecoms plate (37 mm x 22 mm cut-outs)

CR025

100 mm plate for 2 x 50 mm x 50 mm Euro Module

100 mm plate for 3 x 45 mm x 45 mm Arteor modules

Please advise illustrations

CR035

CR070

NOTE : P lease consult us for different plate options on +44 (0) 370 608 9020. Product drawings are only illustrative.

28


Includes 1 x twin switched socket outlet

Includes 2 x twin switched socket outlet

Includes 1 x 2 gang RCD socket outlet

Includes 2 x 2 gang RCD socket outlet

Modular RCD protecting 2 x twin switched socket outlets and 1 spare compartment

DP1332 - 3 m

CR120

CR122

CR120R

CR122R

CR4402

DP1532 - 5 m

CR121

CR123

CR121R

CR123R

CR4403

JP2332 - 3 m

CR130

CR132

CR130R

CR132R

CR4412

JP2532 - 5 m

CR131

CR133

CR131R

CR133R

CR4413

YP5332 - 3 m

CR124

CR126

CR124R

CR126R

CR4406

YP5532 - 5 m

CR125

CR127

CR125R

CR127R

CR4407

4 compartment

Electrak 24 - standard tap-off

Electrak 25 - low noise / clean earth tap-off

230 mm 366

mm

Electrak 28 - auxiliary earth tap-off

Additional plates for 4 compartment boxes

Blank plate

CR4100

4 x BNC connector plate

CR4108

Angled punched plate for 4 x RJ45 sockets (37 mm x 22 mm cut-outs)

CR4115

4 x Data / telecoms plate (37 mm x 22 mm cut-outs)

CR4112

2 x LJ2 accessory plate (50 mm fixing centres)

CR4106

6 x Data / telecoms plate (37 mm x 22 mm cut-outs)

CR4113

100 mm plate for 2 x 50 mm x 50 mm Euro Module

CR4110

100 mm plate for 3 x 45 mm x 45 mm Arteor modules

CR4200

NOTE : P lease consult us for different plate options on +44 (0) 370 608 9020. Product drawings are only illustrative.

29


access floor service outlet boxes

slab and screed mounted floor boxes

empty boxes

empty boxes

CR5302

CR4002 3 compartment slab floor box shown with two twin switched socket outlets, punched data plate and a powertrack tap-off CR5312

Includes grey ABS lid and trim

CR012

Selection charts p. 26 Dimensions and technical information p. 33 id and trim mouldings are precision engineered from hard wearing L durable ABS. Lid is reinforced with a galvanised mild steel plate Mounting frame and box base - 0¡9 mm thick galvanised steel Each compartment has 2 entries for 20 mm and 2 entries for 25 mm flexible conduits Grey mouldings. Alternative colours available to special order Grey plates 2, 3 and 4 compartment boxes are also available with separate individual compartment base units for convenient offsite pre-wiring Supplied in parts or fully assembled and configured to customer specification Conform to BS EN 61534-22

Pack

Cat. Nos.

2 compartment floor boxes

Empty boxes

1 1 1 1 1 1

100 mm compartment widths

CR2001 Single base - 75 mm depth CR2002 Single base - 85 mm depth (standard box) CR2003 Single base - 110 mm depth CR2004 Separate compartment base - 75 mm depth CR2005 Separate compartment base - 85 mm depth CR2006 Separate compartment base - 110 mm depth

3 compartment floor boxes

Empty boxes

100 mm compartment widths

1 1 1 1 1 1

CR011 Single base - 75 mm depth CR012 Single base - 85 mm depth (standard box) CR013 Single base - 110 mm depth CR014 Separate compartment base - 75 mm depth CR015 Separate compartment base - 85 mm depth CR016 Separate compartment base - 110 mm depth

Selection charts p. 26 Dimensions and technical information p. 33 Electrak slab floor boxes are an ideal solution for underfloor power and data requirements Used in conjunction with Electrak floor grommets, slab boxes prevent unwanted access to power and data connections

Pack

Empty boxes

75 mm compartment widths

NOTE: due to plug entry requirements, 4 x twin socket outlets will not fit into a 4 compartment floor box 1 CR4001 Single base - 75 mm depth

30

1 1 1 1 1

CR4002 Single base - 85 mm depth (standard box) CR4003 Single base - 110 mm depth CR4004 Separate compartment base - 75 mm depth CR4005 Separate compartment base - 85 mm depth CR4006 Separate compartment base - 110 mm depth

Slab floor boxes

Fixes directly onto floor slab Fast and efficient installation with integrated fixing plates Wide range of power and data accessory plates Manufactured from 0¡9 mm thick galvanised steel Each compartment has 2 entries for 20 mm and 2 entries for 25 mm flexible conduits 100 mm compartment widths Use plates from the 1, 2 and 3 compartment floor box section p. 26-27 1 CR5102 1 compartment slab floor box 1 CR5202 2 compartment slab floor box 1 CR5302 3 compartment slab floor box 75 mm compartment widths Use plates from the 4 compartment floor box section p. 26-27

1

CR5402 4 compartment slab floor box

4 compartment floor boxes

Cat. Nos.

Screed floor boxes

25 mm conduit fed, to suit screed 75 mm to 90 mm deep 1 CR5312 3 compartment screed floor box 1 CR5412 4 compartment screed floor box

NOTE : P lease consult us for different plate options on +44 (0) 370 608 9020. Photos are only illustrative.

Edge trim boxes, and metal or lockable lids are available to order contact us on +44 (0) 370 608 9020


access floor service outlet boxes accessory plates and ancillary items

Selection charts p. 26-29 Dimensions and technical information p. 33 Lid and trim mouldings are precision engineered from hard wearing durable ABS. Lid is reinforced with a galvanised mild steel plate Mounting frame and box base - 0·9 mm thick galvanised steel Each compartment has 2 entries for 20 mm and 2 entries for 25 mm flexible conduits Grey mouldings. Alternative colours available to special order. Grey plates 2, 3 and 4 compartment boxes are also available with separate individual compartment base units for convenient offsite pre-wiring Supplied in parts or fully assembled and configured to customer specification Conform to BS EN 61534-22

Pack

Cat. Nos. 1,

2 and 3 compartment accessory plates

100 mm width

1 CR020 Blank plate 1 CR022 2 gang switched socket outlet 1 CR023 2 gang switched socket outlet, low noise / clean earth 1 CR027 2 gang non-standard switched socket outlet 1 CR029 2 gang unswitched socket outlet 1 CR030 3 gang unswitched socket outlet 1 CR044 3 gang unswitched socket outlet, low noise / clean earth 1 CR036 2 gang RCD socket outlet 1 CR043 2 gang RCD socket outlet, low noise / clean earth 1 CR046 100 mm plate – 2 gang RCD switched shallow socket outlet specifically for 75 mm deep floor boxes 1 CR053 100 mm plate – low noise 2 gang RCD switched shallow socket outlet specifically for 75 mm deep floor boxes 1 CR026 Punched plate for 2 x 1 gang accessories (60·3 mm fixing centres) 1 CR028 Punched plate for 2 gang accessories (120·6 mm fixing centres) 1 CR042 Angled punched plate for 4 x RJ45 (37 mm x 22 mm cut-outs) 1 CR031 2 x LJ2 accessory plate (50 mm fixing centres) 1 CR033 4 x BNC connector plate 1 CR024 4 x Data / telecoms plate (37 mm x 22 mm cut-outs) 1 CR025 6 x Data / telecoms plate (37 mm x 22 mm cut-outs) 1 CR035 100 mm plate for 2 x 50 mm x 50 mm Euro Module 1 CR070 100 mm plate for 3 x 45 mm x 45 mm Arteor modules

Pack

Cat. Nos.

4 compartment accessory plates 75 mm compartment widths

1 CR4100 Blank plate 1 CR4101 2 gang switched socket outlet 1 CR4102 2 gang switched socket outlet, low noise / clean earth 1 CR4103 2 gang non-standard switched socket outlet 1 CR4104 2 gang unswitched socket outlet 1 CR4105 3 gang unswitched socket outlet 1 CR4118 3 gang unswitched socket outlet, low noise / clean earth 1 CR4111 2 gang RCD socket outlet 1 CR4117 2 gang RCD socket outlet, low noise / clean earth 1 CR4121 75 mm plate – 2 gang RCD switched shallow socket outlet specifically for 75 mm deep floor boxes 1 CR4127 75 mm plate – low noise 2 gang RCD switched shallow socket outlet specifically for 75 mm deep floor boxes 1 CR4115 Angled punched plate for 4 x RJ45 (37 mm x 22 mm cut-outs) 1 CR4106 2 x LJ2 accessory plate (50 mm fixing centres) 1 CR4108 4 x BNC connector plate 1 CR4112 4 x Data / telecoms plate (37 mm x 22 mm cut-outs) 1 CR4113 6 x Data / telecoms plate (37 mm x 22 mm cut-outs) 1 CR4110 75 mm plate for 2 x 50 mm x 50 mm Euromod 1 CR4200 75 mm plate for 3 x 45 mm x 45 mm Arteor modules

1 1 10 10 50 1 1 1 1 1 1

1

10 1

Ancillary items for service outlet boxes

CR0001 Floor tile cut-out template – 2 compartment CR0003 Floor tile cut-out template – 3 / 4 compartment CR0000 Cable outlet flap CR0010 Cable routers CR0011 Screws for accessory plates CR0012 Pack of 5 keys for use with lockable floor boxes CR0021 Plastic lid and trim for 2 compartment floor box CR0022 Plastic lid and trim for 3 / 4 compartment floor box CR0023 Lockable lid assembly for 2 compartment floor box CR0024 Lockable lid assembly for 3 / 4 compartment floor box CR0005 Mounting frame for vinyl floor. For 2 compartment box Replaces mounting frame attached to base CR0006 Mounting frame for vinyl floor. For 3 / 4 compartment box. Replaces mounting frame attached to base CR0007 Floor box lid handle CR0020 Metal lid and trim - replacement for 3 and 4 compartment boxes - powder coated grey

Electrak tap-offs p. 10-14, 16-17 31


access floor pre-wired service outlet boxes 3 and 4 compartment

CR100

CR122

Selection chart p. 28-29 Dimensions and technical information p. 33 Electrak floor boxes can be supplied pre-wired to powertrack tap-offs with any variation of sockets, tap-offs, depth or other configuration

Pack

Cat. Nos.

3 compartment pre-wired boxes with 1 x TSSO

100 mm compartment widths

Single base – 85 mm depth, pre-wired with : 1 CR100 3 m Electrak 24 standard tap-off Cat. No. DP1332 1 CR101 5 m Electrak 24 standard tap-off Cat. No. DP1532 1 CR110 3 m Electrak 25 low noise / clean earth tap-off Cat. No. JP2332 1 CR111 5 m Electrak 25 low noise / clean earth tap-off Cat. No. JP2532 1 CR104 3 m Electrak 28 auxiliary earth tap-off Cat. No. YP5332 1 CR105 5 m Electrak 28 auxiliary earth tap-off Cat. No. YP5532

Pack

Cat. Nos.

100 mm compartment widths

Single base – 85 mm depth, pre-wired with : 1 CR102 3 m Electrak 24 standard tap-off Cat. No. DP1332 1 CR103 5 m Electrak 24 standard tap-off Cat. No. DP1532 1 CR112 3 m Electrak 25 low noise / clean earth tap-off Cat. No. JP2332 1 CR113 5 m Electrak 25 low noise / clean earth tap-off Cat. No. JP2532 1 CR106 3 m Electrak 28 auxiliary earth tap-off Cat. No. YP5332 1 CR107 5 m Electrak 28 auxiliary earth tap-off Cat. No. YP5532

Also available : - pre-wired boxes with fused tap-offs - shallow or deep versions - separate compartment bases contact us on +44 (0) 370 608 9020

32

75 mm compartment widths

Single base – 85 mm depth, pre-wired with : 1 CR120 3 m Electrak 24 standard tap-off Cat. No. DP1332 1 CR121 5 m Electrak 24 standard tap-off Cat. No. DP1532 1 CR130 3 m Electrak 25 low noise / clean earth tap-off Cat. No. JP2332 1 CR131 5 m Electrak 25 low noise / clean earth tap-off Cat. No. JP2532 1 CR124 3 m Electrak 28 auxiliary earth tap-off Cat. No. YP5332 1 CR125 5 m Electrak 28 auxiliary earth tap-off Cat. No. YP5532

4 compartment pre-wired boxes with 2 x TSSO

3 compartment pre-wired boxes with 2 x TSSO

4 compartment pre-wired boxes with 1 x TSSO

75 mm compartment widths

Single base – 85 mm depth, pre-wired with : 1 CR122 3 m Electrak 24 standard tap-off Cat. No. DP1332 1 CR123 5 m Electrak 24 standard tap-off Cat. No. DP1532 1 CR132 3 m Electrak 25 low noise / clean earth tap-off Cat. No. JP2332 1 CR133 5 m Electrak 25 low noise / clean earth tap-off Cat. No. JP2532 1 CR126 3 m Electrak 28 auxiliary earth tap-off Cat. No. YP5332 1 CR127 5 m Electrak 28 auxiliary earth tap-off Cat. No. YP5532 Pre-wired floor boxes can be supplied with RCD rather than standard sockets. Add an R to the end of the part numbers for an RCD version. For example CR100R is a 3 compartment floor box with a twin RCD socket and a DP1332 tap-off

NOTE : P lease consult us for different plate options on +44 (0) 370 608 9020. Photos are only illustrative.


access floor service outlet boxes

access floor service outlet boxes

with RCD protection

technical information n Floor boxes Dimensions Lid can accommodate carpets up to 6 mm depth Accessory plates are 172 mm long, with 162 mm fixing centres Materials Lid and trim mouldings are precision engineered from hard wearing durable ABS. Lid is reinforced with a galvanised mild steel plate Mounting frame and box base – 0¡9 mm thick galvanised steel Floor service unit conforms to BS EN 61534-22 Wiring Each compartment has 2 entries for 20 mm and 2 entries for 25 mm flexible conduits Colour Grey mouldings. Alternative colours available to special order Grey plates

CR4401

Selection charts p. 26-29 Dimensions and technical information (opposite)

Dimensions from top of floor tile into floor void

Electrak floor boxes are available with various RCD protection options and can be supplied pre-wired to powertrack tap-offs

Pack

C A

Cat. Nos. Floor

boxes with RCD protection and 2 x TSSO

B

Boxes contain 1 spare 75 mm width compartment

1 1

CR4400 Includes standard sockets CR4401 Includes low noise sockets

Pre-wired RCD protected floor boxes

Boxes contain RCD and 2 x TSSO with 1 spare 75 mm compartment 1 1 1 1

CR4402 CR4403 CR4412 CR4413

Pre-wired Pre-wired Pre-wired Pre-wired

with with with with

Cat. Cat. Cat. Cat.

No. No. No. No.

DP1332 tap-off DP1532 tap-off JP2332 tap-off JP2532 tap-off

303

35 45 45

35 35 60

Compartment

W L (mm) (mm)

350 245 350 245

3C 4C

n To install access floor box

15 max adjustment to bring level with finished floor Screed

25 Trunking 15 ribbon screed Structural floor slab

15 max adjustment to bring level with finished floor 75

75 85 110

Screed floor boxes

221

60

A B C Accessory Underside lid to top box depth of accessory (mm) (mm) (plug clearance) (mm)

Screed

38 Trunking 15 ribbon screed Structural floor slab

L

W

15 max adjustment to bring level with finished floor

Cut hole in raised floor tile, lower completeScreed box into 25 Trunking aperture and push firmly 15 ribbon screed down Structural floor slab

60

15 max adjustment to bring level with finished floor 75

Screed

38 Trunking 15 ribbon screed Structural floor slab

Floor tile cut-out dimensions 2 compartment : 263 mm x 203 mm1 3 and 4 compartment : 340 mm x 203 mm1 Floor cut-out aperture is the same for single base or separate compartment base To fit carpet : Detach lid and trim assembly by lifting the blue locking handles and lifting out. Cut and fit carpet. Push lid and trim assembly back into place

NOTE : P lease consult us for different plate options on +44 (0) 370 608 9020. Photos are only illustrative.

1 : The aperture dimension 203 mm has a fixing tolerance between 203 to 205 mm

33


FLOOR GROMMETS perfectly balancing

capacity & size ACCESS GROMMETS The Electrak range of simple-to-install access grommets allow cables and conduit to link between underfloor power and desk power systems. n n

n

34

Ranging from 144mm to 232mm in diameter 69mm diameter grommet can accommodate up to 3 x 1 32mm conduits - perfectly balancing capacity and size Push-fit lid with optional screw fixing to prevent unauthorised access


POWER AND DATA GROMMETS

n

n

The Electrak range of cleaner’s grommets are the latest addition to its power and data grommets range. Within their 169mm diameter, the grommet can house a flat RCD socket and provide ample space for the user to plug in or unplug equipment.

n

n

leaner’s grommet with flat C mounted RCD socket or standard socket options Push-fit lid with cable flap feature pring loaded screws for rapid S installation vailable pre-wired to powertrack A tap-off

1 1

2

3

4

5 6

Removable inlay for optional carpet fitting Cable flap allows permanent connection of services Flat mounted RCD socket

169mm diameter provides the perfect balance between size and capacity Spring loaded screws for rapid installation Available pre-wired to powertrack tap-offs 35


floor grommets access / power and data

EG0030

EG0010

EG0040

EG0045

Dimensions and technical information p. 37

Pack

Cat. Nos.

Plastic access grommets

Pack

Cat. Nos.

Plastic power and data grommets

Quick fit installation 169 mm Ø – cut-out size 152 mm Ø Precision engineered from hard wearing durable ABS Quick fit installation Grey mouldings. Other colours available to special Precision engineered from hard wearing durable ABS order Grey mouldings. Other colours available to special Conform to BS EN 61534-22 order. Conform to BS EN 61534-22 Simply secured by pushing down the spring-loaded Removable carpet recess screws and rotating a quarter turn Cable flap feature so grommet lid can be closed Recommended for use in light traffic areas while in use Avoid positioning in walkways or under static loads Simply secured by pushing down the spring-loaded screws and rotating a quarter turn 1 EG0010 144 mm Ø – cut-out size 127 mm Ø Recommended for use in light traffic areas Can accomodate all cable types or three metal Avoid positioning in walkways or under static loads conduits up to a 20 mm Ø or 25 mm without foam 1 EG0040 13 A power grommet 1 EG0030 169 mm Ø – cut-out size 152 mm Ø Supplied complete with 13 A unswitched socket Allows power, data and flexible conduit up to 32 mm to pass through raised access floor 1 EG0045 RCD power grommet Lid can be locked with screw (included) Supplied complete with 13 A RCD socket Maximum number of conduits : 1 EG0051 13 A power/data grommet 9 x 20 mm Ø Supplied complete with 13 A socket and 5 x 25 mm Ø 1 x 37 x 22 mm cut-out 3 x 32 mm Ø 1 EG0052 Data grommet 1 EG0055 232 mm Ø – cut-out size 215 mm Ø Supplied complete with data plate 2 x 37 x 22 mm cut-out High capacity grommet Recommended for installation in light traffic areas Cleaners floor grommets 169 mm Ø

Aluminium access grommet

Body – cast aluminium Lid – injection moulded plastic Nylon 66 with neoprene cable gasket Secured by quarter-turn fasteners Floor depth 25 to 55 mm Access grommet depth 60 mm (95 mm when back box included) 1 EG0015 144 mm Ø – cut-out size 127 mm Ø Allows power, data and flexible conduit up to 25 mm to pass through raised access floor

Aluminium power grommet

1 EG0025 13 A power grommet Supplied complete with 13 A switched socket

36

1 1

EG0053 Non-standard 5 A socket EG0035 Single switched socket

Pre-wired power grommets Recommended for use in light traffic areas 169 mm Ø – cut-out size 152 mm Ø Cleaners socket version 1 EG0041 DP1332 - 3 m unfused 1 EG0042 DP1532 - 5 m unfused 1 EG0043 DP1313 - 3 m 13 A fused 1 EG0044 DP1513 - 5 m 13 A fused RCD socket version 1 EG0046 DP1332 - 3 m unfused 1 EG0047 DP1532 - 5 m unfused 1 EG0048 DP1313 - 3 m 13 A fused 1 EG0049 DP1513 - 5 m 13 A fused


floor grommets technical information

144 mm Ø

n 144 mm Ø plastic floor grommet

55 mm

n To install plastic floor grommets

Dimensions Cat. No. EG0010

A

B

Lift handle and pull to remove lid

Push grommet into raised floor tile aperture Push down spring loaded screws and rotate quarter turn to secure Ensure wings are located under floor panel For honeycombed floor panels one wing should face downwards and one wing should face upwards

C

D

E

Slide lid into lug holes

(1) Push down lid to close (2) If grommet is not in use, replace cable access insert

144 mm Ø

55 mm 90

Recommended hole cutter is a 5"/127 mm hole saw blade

125 mm min 127 mm min

Wing

Floor panel cut-out diameter

n 169 mm Ø plastic floor grommets

90 mm

Dimensions 125 mm min 127 mm min

Access grommet Cat. No. EG0030

Recommended hole cutter is a 5"/127 mm hole saw blade

55

Floor panel cut-out diameter

1

2

Ø148 Ø 169

60

Power grommet

102

Cable access insert Drop cable access insert into housing opening

Ø148

90

n 144 mm Ø aluminium grommets Access grommet

Ø 169

Recommended hole cutter is a 6’’/152 mm hole saw blade

Cat. No. EG0015 60

n 232 mm Ø plastic floor grommet

40

60 95

Dimensions Large quick fit grommet Cat. No. EG0055

90

232 mm Ø

13 A power grommet

144

58 mm

Cat. No. EG0025 40

60 95

213 mm min 215 mm max

Floor panel cut-out diameter Recommended hole cutter is a adjustable hole saw blade with Ø range of 40 mm - 300 mm

144

Recommended hole cutter is a 5’’/127 mm hole saw blade

All dimensions (mm) are nominal

37


INTERSOC-R

TM

fast, reliable, adaptable

modular desk power

38


COMPLETE SOLUTIONS FOR DEMANDING ENVIRONMENTS Intersoc-R is a modular desk power system designed to meet the demands of modern workplaces for faster and more adaptable solutions. Designed with speed of installation and flexibility in mind, Intersoc-R’s modular configuration enables thousands of different combinations to be made providing solutions for every installation requirement.

n

n

n

n

Modular system - rapid configuration and easy workstation relocation ush-fit connection - modules P can simply be disconnected and additional modules inserted usbar interconnection B no need for wiring Easily adapted to meet the changing demands of the workplace

39


The next

GENERATION

of power distribution

Available in standard and clean earth versions, with fixed or rotatable socket options and a safe shuttered electrical connection, Intersoc-R is the next generation of power distribution... n

n

n

n

40

Intersoc On-desk Personal power and data system

Simple push-fit, module connection with auto-lock mechanism creates robust joints and makes installation quicker and easier 2 A system with safe shuttered electrical connections 3 for additional safety, meets the requirements of BS 7671 : 2018 (including section 543.7) CB, RCD and RCBO modules, with reversible hinged M covers, provide a full range of circuit protection options , 3 or 4 gang British standard socket modules 2 with fixed or rotatable, fused or unfused (BS 6396) sockets options - all the options you need to meet the requirements of any installation

Outgoing connections: flexible interlink or end cap with ST or GST options n

NEW

Find out more on page 48


41 41


Intersoc-RTM desk modules electrical supply

IAB301A

IAB002A IAB660B IAB312A

IAB610BB

Dimensions and technical information p. 44-47 Intersoc-R features fast modular connection with push-fit auto lock mechanism, safe shuttered electrical connections and a robustly designed rigid joint between modules. Available in standard and clean earth versions Independently approved by Intertek. Complies with BS 5733 and the relevant parts of BS 1363 part 2. Manufactured in an approved ISO 9001 : 2015 facility. Meets the requirements of BS 7671 : 2018 for high integrity earthing (section 543·7)

Pack

Cat. Nos.

1 1 1 1

32 A pre-wired feed modules Standard earth tap-offs (E24 - White tap-off)

IAB311A 3 m unfused metal tap-off Cat. No. DP1332 IAB312A 5 m unfused metal tap-off Cat. No. DP1532 IAB315A 3 m 13 A fused 543·7 metal tap-off Cat. No. DP1327 IAB316A 5 m 13 A fused 543·7 metal tap-off Cat. No. DP1527

Low noise / clean earth tap-offs (E25 - Green tap-off)

1 1 1 1

IAC311A 3 m unfused metal tap-off Cat. No. JP2332 IAC312A 5 m unfused metal tap-off Cat. No. JP2532 IAC315A 3 m 13 A fused 543·7 metal tap-off Cat. No. JP2327 IAC316A 5 m 13 A fused 543·7 metal tap-off Cat. No. JP2527

1 1 1 1

IAF311A 3 m unfused metal tap-off Cat. No. YP5332 IAF312A 5 m unfused metal tap-off Cat. No. YP5532 IAF315A 3 m 13 A fused 543·7 metal tap-off Cat. No. YP5327 IAF316A 5 m 13 A fused 543·7 metal tap-off Cat. No. YP5527

1 1

Auxiliary earth tap-offs (E28 - Red tap-off)

32 A re-wirable feed modules

IAB301A Standard earth (for flexible conduit) IAC301A Low noise (for flexible conduit)

32 A feed units with in-built Neutrik connectors

1 1

IAB301E Standard earth IAC301E Low noise

32 A tap-offs pre-wired to Neutrik connectors (NAC3 - 2FC)

1 1 1 1

42

1 1 1 1

Standard earth tap-offs (E24)

IAB311E 3 m unfused metal tap-off Cat. No. DP1332 IAB312E 5 m unfused metal tap-off Cat. No. DP1532 IAB315E 3 m 13 A fused 543·7 metal tap-off Cat. No. DP1327 IAB316E 5 m 13 A fused 543·7 metal tap-off Cat. No. DP1527 Low noise / clean earth tap-offs (E25)

IAC311E 3 m unfused metal tap-off Cat. No. JP2332 IAC312E 5 m unfused metal tap-off Cat. No. JP2532 IAC315E 3 m 13 A fused 543·7 metal tap-off Cat. No. JP2327 IAC316E 5 m 13 A fused 543·7 metal tap-off Cat. No. JP2527

Pack

1 1 1

Cat. Nos. 16

A feed modules pre-wired to 13 A fused plug

IAB002A With 2 m 1·5 mm2 cable IAB003A With 3 m 1·5 mm2 cable IAB005A With 5 m 1·5 mm2 cable

1

16 A rewirable feed modules

IAB201A Rewirable feed module (for cable)

16 A feed units with in-built GST connector

1 1

IAB660B Compact feed module with male GST connector IAB201B Feed module with male GST and earth bond lead

16 A pre-wired connection leads

13 A fused plug pre-wired to GST connector

1 1 1

IAB002B With 2 m 1·5 mm2 cable IAB003B With 3 m 1·5 mm2 cable IAB005B With 5 m 1·5 mm2 cable

1 1 1

GST to GST connection leads

IAB610BB 1 m length IAB620BB 2 m length IAB630BB 3 m length


Intersoc-RTM desk modules protection, BS sockets, end caps and interlinks

IAC502R

IAB402A

IAB533F

IAB450A

IAZ001A

IAB703A

IAB600B

IAB610B

IAB504R

Dimensions and technical information p. 44-47 The BS version is available with fixed or rotatable sockets. Individually fused sockets are available to meet the requirements of BS 6396 : 2008 + A1 2015 (5 x 20 mm anti-surge ceramic fuses) A wide range of interconnection solutions are available. When 16 A cabling interconnection is used with 32 A under desk solutions, suitable de-rating protection devices must be incorporated to protect the cables All protection and switching modules, end caps and interlinks are universally compatible with standard and clean earth / low noise systems

Pack

1 1 1 1 1 1 1 1 1 1 1 1

Cat. Nos.

1 1 1 1

1 1

1 1

1 1

1 1

1 1 1 1

3 gang individually fused

4 gang unfused

4 gang individually fused

Socket modules – low noise / clean earth (green sockets) 2 gang unfused

IAC502F Fixed sockets IAC502R Rotatable sockets

3 gang unfused

IAB534F 3·15 A – fixed sockets IAB534R 3·15 A – rotatable sockets

2 gang individually fused

IAB504F Fixed sockets IAB504R Rotatable sockets

modules – low noise / clean earth (green sockets) (continued)

1 1

1 1 1 1

2 gang individually fused

IAC532F 3·15 A – fixed sockets IAC532R 3·15 A – rotatable sockets

1 1

1

3 gang individually fused

IAC533F 3·15 A – fixed sockets IAC533R 3·15 A – rotatable sockets

3 gang unfused

IAC503F Fixed sockets IAC503R Rotatable sockets

4 gang unfused

IAC504F Fixed sockets IAC504R Rotatable sockets

2 gang unfused

IAB533F 3·15 A – fixed sockets IAB533R 3·15 A – rotatable sockets

Cat. Nos. Socket

IAB503F Fixed sockets IAB503R Rotatable sockets

Pack

IAB532F 3·15 A – fixed sockets IAB532R 3·15 A – rotatable sockets

Socket modules – standard (grey sockets)

IAB502F Fixed sockets IAB502R Rotatable sockets

Protection and switching modules

IAB401A With 13 A fuse IAB402A With 13 A fuse and sw/neon IAB403A With 13 A fuse and neon IAB404A 32 A max. single isolation module IAB405A With 30 mA RCD IAB408A With neon indicator IAB420A With 16 A MCB IAB430A With 20 A MCB IAB440A With 32 A MCB IAB450A With 16 A RCBO IAB460A With 20 A RCBO IAB470A With 32 A RCBO

4 gang individually fused

IAC534F 3·15 A – fixed sockets IAC534R 3·15 A – rotatable

End cap

IAZ001A Blank end cap

Intersoc to Intersoc pre-wired interconnection

1 1 1 1 1 1

1 1 1 1 1 1

Power out end caps 16 A

1 1

Without flex

IAB600B End cap with female GST connector IAB600C End cap with female ST connector

1 1 1

32 A

IAB703A 0·3 m length IAB705A 0·5 m length IAB710A 1 m length IAB720A 2 m length IAB730A 3 m length IAB750A 5 m length

16 A

IAB603A 0·3 m length IAB605A 0·5 m length IAB610A 1 m length IAB620A 2 m length IAB630A 3 m length IAB650A 5 m length

With flex to female GST connector

IAB610B 1 m length IAB620B 2 m length IAB630B 3 m length

43


Rewirable Rewirable GST GST 3 Blank socket interconnect interconnect interconnect interconnect Blank module male male male end endcap cap male

4 4socket socketin-feed in-feedmodule module 3 socket 3 socket module module TM

End view

TM 37·9 EndEnd view view Intersoc-R desk modules

Intersoc-R desk modules

technical 37·9 37·9

protection, BS sockets, end caps and interlinks

information

60

214·5 411·5 411·5

2323

60 60

5050

6767

n Under-desk dimensions (mm) 3 socket module End view Rewirable Rewirable GST 2 socket in-feed module GST 4 socket in-feed module Rewirable GST GST Rewirab interconnect interconnect Blank interconnect interconnect Compact and interconnect interconnectinterconnec intercon Blank 37·9 feed unit female female female female socket cket module module 2 socket 4 in-feed 4socket socket module module Feed unit male male male endend capcap male 2 socket in-feed module module 4 socket 4 socket in-feed in-feed module module GST 214·5 214·5

60

IAC5P2F

60

214·5

60 60

411·5

291·5 156·5 156·5

276·5 276·5

291·5 291·5

411·5 411·5

2 socket in-feed module

291·5

60

60

and technical information p. 42-45 156·5 156·5

272·5 272·5

2 socket module

460socket module

5050

60

Pack

1 1 1 1

32 60 60 174·5

60

2 socket 214·5 module

IAB5P4F Grey – 2 P + E IAC5P4F Green – 2 P + CE 32

291·5 77·5 77·5

291·5 60 272·5

60

60

156·5

4 socket modu

60

GST interco Blank 156·5 77 Protection modu male end cap

60

60

75

174·5 411·5

Protection mod

60

60

MCB, RCD protection module

12

Interconnection

174·5 Protection module

MCB, RCD protection module 276·5

67

50

MCB, GST RCD protection module Rewirable interconnect interconnect female female

1 : 84·5 mm depth

156·5

50

23

276·5

291·5

60

2 socket module

End view

75 module 4 socket

110·5

115·5

174·5 50

174·5

115·5

60

156·5

Protection module

75

272·5

Interconnection

60 77·5

50 115·5 MCB, RCD protection module

60

Protection module

Interconnection

60 50 174·5

115·5

All dimensions (mm) are nominal

44

50

115·5 GST 60 interconn female

60 60

32

291·5

2 socket module

32

60

on module

4 socket GST in-feed interconnec Blank 411·5 male end cap Protection module 2 socket module 4 socket module 75 Interconnection Interconnection

Fixed – Rotatable – end view end End view view End view 411·5

4 socket module

60

214·5 272·5 4 socket in-feed module R GST interconnect 75 75 110·5 110·5in fe female 411·5

60 MCB, RCD protection module1 50 23 module 4 socket in-feed 115·5

60

2 socket module

50

60

60

m

2 socket in-feed module

60

411·5 2 socket in-feed module 174·5

male

115·5 60 Rewirable 156·5 GST 37·9 32 50 50 interconnect interconnect Blank 2 socket module77·5 77·5 Interconnection GST 115·5 115·5 male male end cap interconnect Protection module End view 60 156·5 female 4 socket module 60

3 gang fixed 90° grey – IS 1293

4 gang fixed 90° grey – IS 1293 End view

R

60

174·5 174·5 4 socket Grey in-feed IAB5P3F – 2module P protection +E MCB, RCD module IAC5P3F Green – 2 P + CE

3 socket module

GST

50interconnect67 in 67

12

1

End view Protection Protection module module

60

2 gang fixed 90° – IS 1293

1 60 IAB5P2F Grey – 2 P + E 291·5 60 1 IAC5P2F Green – 2 P + CE

dule

156·5

Cat. Nos. 6protection Aprotection Indianmodule socket modules 60 MCB, MCB, RCD RCD module

Blank 50 end cap

1 43socket socketmodule module Rewirable GST Rewirab GST interconnect intercon interconnect interconnec female female female female 4 socket in-feed module

156·5 2 socket in-feed module

view The Intersoc 32End A under-desk range is a complete modular power system Intersoc offers a wide range 115·5 of115·5 international socket options 60 shuttered electrical The Intersoc 32 modular system features safe 2 socket in-feed module 4 socket in-feed module connections and a robustly designed rigid joint between modules All modules connect with single push-fit action and autoMCB, lock RCD protection module

1

4 socket 4 socket module module 60 2 socket in-feed module Interconnection Interconnection 411·5

32

Protection Protection module module 60 60 6060 Dimensions 60 60

12 12

4 socket in-feed module

End view 2 socket 2 socket module module

EndEnd view view 32 32

110·5 110·5

2 socket module

IAB5P4F 60

ule e

7575


n Testing and accreditation

n British Standards BS 6396 : 2008 + A1 2015 Electrical Systems in Office Furniture and Educational Furniture Specification BS 7671 : 2018 incorporating amendment No. 3 : 2015. Requirements for Electrical Installation (IET Wiring Regulations 18th Edition) Electricity at Work Regulations 1989

Independently approved by Intertek Complies with BS 5733 and relevant parts of BS 1363-2 Manufactured within an approved ISO 9001 : 2015 and ISO 14001 : 2015 facility Assessed quality assurance certificate No. 2029

up to 32 A 250 V ~ 50 Hz

Conductor resistance at 20°C Fixed Rotatable 2 socket module 4 socket module

0·8 mΩ 1·6 mΩ

0·9 mΩ 1·7 mΩ

1·5 m V/A 3·0 m V/A 4·0 m V/A

(depending on device)

In-feeds : 16 A +1·5 mm2 32 A +4 mm2 Interconnections : 16 A/32 A +1·5 mm2 +4 mm2

(depending on device)

In-feeds : 16 A +1·5 mm2 32 A +4 mm2 Interconnections : 16 A/32 A +1·5 mm2 +4 mm2

Individually fused at 5A 3·15 A

Regulation 543·7 has particular importance when there is a requirement for a quantity of information technology equipment being supplied from a final circuit in a location where the sum of their protective currents exceeds 10 mA in normal use. Due to current in the protective conductor arising from the use of IT equipment, there is a requirement to provide mechanically protected 4 mm2 conductor (543·7·203 (ii)). Intersoc achieves this when wired in accordance with the installation sheets by providing mechanically protected 5 mm2 protective conductors within the product

Earth fault loop impedance

The standard requires individual socket fusing (as per the table below)

Special note should be taken of regulation 543·7 within BS 7671 : 2018 - Earthing requirements for the installation of equipment having high protective conductor currents

2·0 m V/A 29 m V/A/m 11 m V/A/m

1·5 mΩ 3·0 mΩ 4·0 mΩ

A note on individual socket fusing – BS 6396 Compliance :

Meets the requirements of BS 7671 : 2018 The Health and Safety Executive states that installations which conform to the standards laid down in BS 7671 : 2018 are regarded by the HSE as likely to achieve conformity with the relevant parts of the Electricity at Work Regulations 1989

4·0 m V/A 29 m V/A/m 2·0 m V/A 11 m V/A/m

2 socket module 4 socket module Protection module

For compliance with this standard, socket outlet configurations of up to 4 outlets should be individually fused at 5 A and up to 6 outlets individually fused at 3·15 A

Total number of sockets 2, 3 or 4 sockets 5 or 6 sockets

Volt drop Live and neutral 2 socket module 4 socket module Protection module

Below is a brief outline of the main criteria within the standards : BS 6396 : 2008 + A1 2015 was published with regard to the use of electrical equipment within general office and educational furniture This standard sets out in its scope the use and testing of electrical socket outlets and associated wiring when used together with a 13 A BS 1363 fused plug for mains supply and makes provision for the routing of cables through furniture

Electrical test data Rated current Rated voltage Frequency

Health & Safety Legislation

Material specification Module housing heat resistant ABS Socket outlets polycarbonate Busbars high conductivity copper CW004A (C101) Other metalwork phosphor bronze CW451K (PB102), CW452K (PB103) brass CW507L (CZ107), CW508L (CZ108) high conductivity copper CW004A (C101)1

2·0 mΩ 29 mΩ/m 2·0 mΩ 11 mΩ/m

1 : European grades with nearest British Standard shown in brackets

4·0 m V/A 29 mΩ/m 11 mΩ/m

Mechanical data Number of conductors Busbar conductor cross-sectional area 16 A rewirable in-feed terminal capacity 32 A rewirable in-feed terminal capacity

3 5 mm2 10 mm2 10 mm2 All dimensions (mm) are nominal

45


Intersoc-RTM desk modules installation and configuration n Installation To connect and disconnect Intersoc modules

1. Connection / disconnection to be made by a competent person 2. Before connecting modules ensure they are the correct way up and in line 3. Push modules together one at a time 4. Modules self-lock when fully pushed together 5. To disconnect modules slide green latch to unlock module and pull apart 6. Always end module run with blank end cap or interconnect

Module self-locking latch

Underside of modules shown

To fix modules to surface 1. I nsert through all fixing holes no. 8 pozi-pan screw or M4 bolt to required length 2. Tighten screw / bolt down to mounting surface

Slide green latch

Blank end cap

2 socket module

16 A 4 socket in-feed module

All dimensions (mm) are nominal

46


n Product configuration

1. Select the type of distribution system - standard, or low noise / clean earth 2. Select the means of powering the system - cable or powertrack tap-off 3. Select the type of in-feed module to match the cable capacity - 16 A or 32 A 4. Select the means of protection 5. Select the number of socket modules from the 2, 3 or 4 gang range (individually fused or unfused) 6. Select fixed or rotatable sockets 7. Select the interconnection units if required 8. Finish system with the end cap (All modules push fit and lock together on-site or can be factory assembled to customer requirement)

iiiiiil

Floor grommet

llllllllllllllllllllllllll llllllll lllllllllllllll Underfloor powertrack

1

2

l l ll ll

lllll 32 A in-feed connected to tap-off and left underfloor until required

l l ll

l

l l ll

Tap-off

llll l

lllllllllllllllll

lllllll

Raised floor

ll l l ll l l l l

l l ll

In-feed and power module push together and self-lock when fully pushed home

Tap-off and in-feed pulled through floor grommet after testing and when required

All dimensions (mm) are nominal

47


ON-DESK

power and data for

modern workspaces

ON-DESK RANGE BRINGS POWER, DATA AND RAPID USB CHARGING TO THE MODERN WORKSTATION With clean lines and a stylish aluminium and mirror white finish, Electrak on-desk’s ergonomic design blends in perfectly with contemporary office design schemes and enhances the functionality of the desk space. 48


Tailored to your

requirements Configuring on-desk modules to your exact requirements couldn’t be simpler. Select any combination of power sockets and USB charging modules, and further enhance functionality with plug and play data solutions or Euro modules. Legrand’s modular wiring accessories, including a range of AV solutions, can also be incorporated.

Putting ‘personal’ back into desk power and data… Intersoc on-desk can be tailored to the demands of any workstation

RAPID USB CHARGING

HIGH PERFORMANCE DATA

Intelligent twin USB modules offer a high specification, rapid charge facility that keeps your mobile devices ready should you need to work on the move. Up to two devices (e.g. tablet and smart phone) can be simultaneously charged at a faster rate than common, lower output chargers.

On-desk offers plug and play CAT 5e and CAT 6 data options or CAT 6A keystone jack modules for higher performance. Euro module options are also available to accommodate a customer’s specific data requirements. The innovative design of Intersoc on-desk enables data cables to neatly feed through the rear of the unit (see below).

Watch the on-desk video at www.youtube.com/LegrandtvUK The entire Electrak system is powered by a reliable busbar backbone, from powertrack right through to on-desk modules.

Power is fed to the on-desk unit via a choice of 13 A pre-wired plug, GST connector or an Intersoc-R under-desk connector.

CAT 5e and CAT 6 data outlets are fed neatly from the rear of the unit via simple RJ45 connection (patch leads not supplied).

49 49


RELIABLE DESKTOP

CONNECTIVITY ON-DESK... DELIVERING POWER, DATA AND RAPID USB CHARGING TO THE MODERN WORKPLACE The fast pace of modern work practices combined with the need for instant connectivity is placing an ever greater reliance on the use of multiple devices, whether it be at our workstation or whilst we're on the move. The new range of Electrak on-desk modules offers a convenient answer to the growing demand for user-specific desk power and data access.

50

CAT 5e / 6 / 6A RJ45 outlets


Rapid dual USB charging

BS and International socket options

RELIABLE BUSBAR BACKBONE Building on the success of the Electrak system, on-desk is powered by a busbar backbone which provides a reliable electrical connection.

51


On-desk modules

Pre-wired with 3 m flex and BS 1363 plug

Pre-wired with 1·5 m flex and GST connector

Pre-wired with 1·5 m flex and Intersoc-R connector

Cat. Nos.

Cat. Nos.

Cat. Nos.

2 x sockets individually fused at 3·15 A

PA3320AA

PB1320AA

PD1320AA

3 x sockets individually fused at 3·15 A

PA3330AA

PB1330AA

PD1330AA

4 x sockets individually fused at 3·15 A

PA3340AA

PB1340AA

PD1340AA

2 x sockets individually fused at 3·15 A plus 1 x rear pluggable CAT 5e / CAT 6 RJ45 outlet

PA3320AB

PB1320AB

PD1320AB

2 x sockets individually fused at 3·15 A plus 2 x rear pluggable CAT 5e / CAT 6 RJ45 outlets

PA3320AC

PB1320AC

PD1320AC

2 x sockets individually fused at 3·15 A plus 1 x rear pluggable data USB outlet

PA3320AD

PB1320AD

PD1320AD

PA3320AE

PB1320AE

PD1320AE

PA3320AF

PB1320AF

PD1320AF

PA3320AG

PB1320AG

PD1320AG

Description

20AA

PA33

120 30AA

PA33 107

120 172

20AA

PA33

40AA

PA33 AA

3320

view etric 1:2 Isom : Scale

20AB

PA33

180 232

30AA

PA33

240 20AC

PA33

292

5 152· A5 40A4· PA33 20

.5

7 ( 10

40AA

PA33

PA

t view :2 Fron : 1 Scale

)

152

AB 3320

AD

view etric 1:2 Isom : Scale

20 PA33

2 x sockets individually fused at 3·15 A plus 2 x rear pluggable data USB outlets

175 3 ( 28

227

)

t view :2 Fron : 1 Scale

view etric 1:2 Isom : Scale

20AE

20AC

PA33

2 x sockets individually fused at 3·15 A plus 1 x CAT 6A RJ45 outlet with 3 m data lead

PA33

5

152·

5 204·

PA33

2 x sockets individually fused at 3·15 A plus 2 x CAT 6A RJ45 outlets with 3 m data leads

175

20AG

view etric 1:2 Isom : Scale

20AD

PA33

t view :2 Fron : 1 Scale

20AF

view etric 1:2 Isom : Scale

PA33

227

Fixings Description

20AE

PA33

Desk clamp

t view :2 Fron : 1 Scale

Cat. No. 175 227

t view :2 Fron : 1 Scale

52

0546 99

230 282

ew

20AF

PA33


Pre-wired with 3 m flex and BS 1363 plug

Pre-wired with 1·5 m flex and GST connector

Pre-wired with 1·5 m flex and Intersoc-R connector

Description

Cat. Nos.

Cat. Nos.

Cat. Nos.

2 x sockets individually fused at 3·15 A plus carrier to accept 1 x Euro Module (25 x 50 mm)

PA3320AK

PB1320AK

PD1320AK

2 x sockets individually fused at 3·15 A plus carrier to accept 2 x Euro Modules (50 x 50 mm)

PA3320AL

PB1320AL

PD1320AL

3 x sockets individually fused at 3·15 A plus 1 x rear pluggable CAT 5e / CAT 6 RJ45 outlet

PA3330AB

PB1330AB

PD3330AB

3 x sockets individually fused at 3·15 A plus 2 x rear pluggable CAT 5e / CAT 6 RJ45 outlets

PA3330AC

PB1330AC

PD1330AC

3 x sockets individually fused at 3·15 A plus 1 x rear pluggable data USB outlet

PA3330AD

PB1330AD

PD1330AD

3 x sockets individually fused at 3·15 A plus 2 x rear pluggable data USB outlets

PA3330AE

PB1330AE

PD1330AE

2G 6A Indian non-switched – 1·5 ISOC and no data

–

–

PD1P20AA

2G 6A Indian non-switched – 1·5 ISOC and 1 x C5/6

–

–

PD1P20AB

2G 6A Indian non-switched – 1·5 ISOC and 2 x C5/6

–

–

PD1P20AC

view etric 1:2 Isom : Scale

AK

20 PA33

view etric 1:2 Isom : Scale

20AL

PA33

160 212 AB 3330

PA

20AK

PA33

t view :2 Fron : 1 Scale

185 237

30AB

PA33

t view :2 Fron : 1 Scale

AL

20 PA33

30AB

PA33

30AE

PA33

30AB

PA33

172 120

30AE

PA33

205 152.5

Notes: Other options are available to special order. Contact us on +44 (0) 345 605 4333 CAT 5e / CAT 6 outlets have a rear facing RJ45 that will accept either CAT 5e or CAT 6 data cabling (no data cabling is included with the product) CAT 6A outlets are supplied with 3 m pre-wired lead and performance certificate The data USB outlets have 2a27short flying lead at the rear for USB connection to the PC (no additional data cabling is included with the product) 75 accept Euro Modules will be supplied with apertures at the rear for the passing of data or AV cables Units supplied with carriers1to

53


On-desk modules with twin outlet USB charger

Pre-wired with 3 m flex and BS 1363 plug

Pre-wired with 1·5 m flex and GST connector

Pre-wired with 1·5 m flex and Intersoc-R connector

Cat. Nos.

Cat. Nos.

Cat. Nos.

1 x unfused socket plus twin outlet USB charger

PA3012AA

PB1012AA

PD1012AA

2 x sockets individually fused at 3·15 A plus twin outlet USB charger

PA3322AA

PB1322AA

PD1322AA

3 x sockets individually fused at 3·15 A plus twin outlet USB charger

PA3332AA

PB1332AA

PD1332AA

1 x unfused socket, twin outlet USB charger plus 1 x rear pluggable CAT 5e / CAT 6 RJ45 outlet

PA3012AB

PB1012AB

PD1012AB

1 x unfused socket, twin outlet USB charger plus 2 x rear pluggable CAT 5e / CAT 6 RJ45 outlets

PA3012AC

PB1012AC

PD1012AC

1 x unfused socket, twin outlet USB charger plus 1 x rear pluggable data USB outlet

PA3012AD

PB1012AD

PD1012AD

1 x unfused socket, twin outlet USB charger plus 2 x rear pluggable data USB outlets

PA3012AE

PB1012AE

PD1012AE

2 x sockets individually fused at 3·15 A, twin outlet USB charger plus 1 x rear pluggable CAT 5e / CAT 6 RJ45 outlet

PA3322AB

PB1322AB

PD1322AB

2 x sockets individually fused at 3·15 A, twin outlet USB charger plus 2 x rear pluggable CAT 5e / CAT 6 RJ45 outlets

PA3322AC

PB1322AC

PD1322AC

Description

12AA

PA30

113

115

22AA

PA33

283

32AA

12AA

PA33

PA30

175 227

22AA

PA33

12AC

PA30

AA

32 PA33

12AD

PA30

12AC

PA30

12AE

PA30

view etric 1:2 Isom : Scale

12AD

PA30

207

.5

view etric 1:2 Isom : Scale

AC 3322

PA

7 ) ( 10

AB

22 PA33

12AE

PA30

Fixings Description

Cat. No.

283 230

Desk clamp

0546 99 22AB

PA33

) ( 78

t view :2 Fron : 1 Scale

54 282


Pre-wired with 3 m flex and BS 1363 plug

Pre-wired with 1·5 m flex and GST connector

Pre-wired with 1·5 m flex and Intersoc-R connector

Cat. Nos.

Cat. Nos.

Cat. Nos.

2 x sockets individually fused at 3·15 A, twin outlet USB charger plus 1 x rear pluggable data USB outlet

PA3322AD

PB1322AD

PD1322AD

2 x sockets individually fused at 3·15 A, twin outlet USB charger plus 2 x rear pluggable data USB outlets

PA3322AE

PB1322AE

PD1322AE

2 x sockets individually fused at 3·15 A, twin outlet USB charger plus 1 x CAT 6A RJ45 outlet with 3 m data lead

PA3322AF

PB1322AF

PD1322AF

2 x sockets individually fused at 3·15 A, twin outlet USB charger plus 2 x CAT 6A RJ45 outlets with 3 m data leads

PA3322AG

PB1322AG

PD1322AG

2 x sockets individually fused at 3·15 A, twin outlet USB charger plus carrier to accept 1 x Euro Module (25 x 50 mm)

PA3322AK

PB1322AK

PD1322AK

2 x sockets individually fused at 3·15 A, twin outlet USB charger plus double carrier to w accept 2Fronxlet vi: eEuro Modules (50 x 50 mm) 1:2

PA3322AL

PB1322AL

PD1322AL

–

–

PD1P22AA

–

–

PD1P22AB

–

–

PD1P22AC

Description

view etric 1:2 Isom : Scale 22AD

PA33

207

22AE

) ( 78

PA33

.5

view etric 1:2 Isom : Scale

283

view etric 1:2 Isom : Scale

22AF

PA33

22AD

PA33

t view :2 Fron : 1 Scale

) ( 78

230

282 22AG

PA33

391 230

22AE

PA33

t view :2 Fron : 1 Scale

22AK

PA33

view etric 1:2 Isom : Scale

22AG

PA33

Sca

22AF

PA33

2G 6A Indian non-switched – 2 USB : 1·5 m ISOC and no data 7 ( 10

)

215

2G 6A Indian non-switched – 2 USB : 1·5 m ISOC and 1 x C5/6 7 ( 26

227 175

t view :2 Fron : 1 Scale

)

22AK

PA33

2G 6A Indian non-switched – 2 USB : 1·5 m ISOC and 2 x C5/6

Notes:

260 207.5

Other options are available to special order. Contact us on +44 (0) 345 605 4333 CAT 5e / CAT 6 outlets have a rear facing RJ45 that will accept either CAT 5e or CAT 6 data cabling (no data cabling is included with the product) CAT 6A outlets are supplied82 with 3 m pre-wired lead and performance certificate 2 The data USB outlets have 2a30short flying lead at the rear for USB connection to the PC (no additional data cabling is included with the product) Units supplied with carriers to accept Euro Modules will be supplied with apertures at the rear for the passing of data or AV cables

55


On-desk modules technical information Isometric view 1:2

PA3320AD

Scale : PA3320AC

78

n On-desk dimensions (mm)

91

175

PA3320AE

Isometric view Scale : 1:2

227

PA3320AD PA3320AC 90 90

3320AA

PA3322AA

Isometric view Scale : 1:2

To suit desk thickness of 6–40 mm

To suit desk thickness of 6–40 mm

54

152·5 204·5 PA3320AF

35

PA3320AE Front view Scale:

PA3320AA

PA3320AD

1:2

PA3330AA

175 227 120

Isometric view Scale : 1:2

172

PA3322AA PA3320AA

CARTON LABEL POSITION DETAIL

PA3340AA

PA3320AG

PA3320AF

Front view Scale: 1:2

PA3320AE

175 227

Isometric175 view Scale : 227 1:2

PA3320AK

PA3330AA PA3320AG PA3322AA

Front view Scale: 1:2

Isometric view Scale : 1:2

PA3320AL

180

PA3320AF

232

230

Isometric view Scale PA3340AA : 1:2

282

PA3320AK PA3330AA

Front view Scale: 1:2

PA3320AG

240 292

160

PA3320AB

212 PA3340AA

PA3320AL Front view Scale: 1:2

PA3320AK

152·5 204·5

185 237

All dimensions (mm) are nominal

Front view Scale: 1:2

56

PA3320AB

Front view Scale: 1:2

PA3320AL


n On-desk dimensions (mm) (continued)

n Testing and accreditation

PD1P22AA 227 175

Complies with BS 5733 and relevant parts of BS 1363-2 Manufactured within an approved ISO 9001 : 2015 and ISO 14001 : 2015 facility

n BS 6396 : 2008 + A1 2015 Electrical Systems in Office Furniture and Educational Furniture Specification

PD1P22AB 260 207.5

Below is a brief outline of the main criteria within the standards : BS 6396 : 2008 + A1 2015 was published with regard to the use of electrical equipment within general office and educational furniture. This standard sets out in its scope the use and testing of electrical socket outlets and associated wiring when used together with a 13 A BS 1363 fused plug for mains supply and makes provision for the routing of cables through furniture The standard requires individual socket fusing (as per the table below)

PD1P22AC 282 230

Total number of sockets 2, 3 or 4 sockets 5 or 6 sockets

Individually fused at up to

5A 3·15 A

BS 6396 : 2008 + A1 2015 requires RCD protection for electrical sockets Material specification Module housing Module fascia Socket outlets End caps

PD1P20AA 172

aluminium / PVC polycarbonate / ABS polycarbonate ABS

120

USB charger module specification

PD1P20AB 205 152.5

Supply voltage (nominal) Supply current Power consumption (max.) Frequency Output voltage Output current Output power Over current protection Output connectors Current per socket

230 V (AC) 1·3 mA 0·3 W 50 Hz +5·0 V ± 0·25 (DC) 3·1 A 15 W (max.) 3·8 A (max.) 2 x USB Type A sockets 2·1 A (max.)

PD1P20AB 227 175

All dimensions (mm) are nominal

57


ELECTRAK IN-DESK

enhancing the workstation

IN-DESK BRINGS STYLE AND FLEXIBILITY TO THE WORKSTATION Made from high quality brushed stainless steel, In-desk is designed to complement the aesthetic of modern workspaces, giving users power when they need it and minimal, sleek design when they don’t.

58


With the simple touch of a button, the unit elegantly rises from the desk in a smooth action to reveal either a traditional twin socket arrangement or a single socket with twin USB outlets for charging mobile devices.

EASY INSTALLATION The Electrak In-desk range is pre-wired with a BS plug, GST or Intersoc-R connector for simple tool-free electrical connection.

MINIMAL AND DISCREET When power isn’t required, the ultra-slim brushed stainless steel cover closes to fit discreetly into the desktop.

59


POWER SET FREE

In-desk units

wireless charging

Legrand’s Qi certified induction charger can be easily installed into desks, tables and other furniture – allowing Qi enabled smartphones and other mobile devices to be charged simply by placing them on top. Charging has never been more simple. Extra flat, supplied with a micro USB/USB cable and a USB mobile power supply (Cat. No. 077580).

POPA3012AA

POPA3020AA

077580

Dimensions and technical information p. 61 Classification of In-desk flush-mounting boxes according to NFC 61-314 / EN 60670-1 : 2005 + A1 : 2013 Protection against mechanical impact: IK 07 Degree of ingress protection: IP 30 cover open, IP 40 cover closed

Pack

Cat. Nos.

In-desk units

USB power supply for recharging portable devices Conforms to IEC 62684-2011-01 Consumption in passive mode < 0.1 W Double USB sockets - 5 V - 2400 mA For fast charging telephones, smartphones, MP3/MP4 players and tablet PC British standard socket outlet: shuttered for child safety ASTA licenced Conforms to BS 1363 Part 2 Unit with single socket and twin USB outlets

1 1 1

POPA3012AA Unit with 3m lead and BS 1363 plug POPB1012AA Unit with 1.5m lead and GST connector POPD1012AA Unit with 1.5m lead and Intersoc-R connector

1 1 1

Unit with twin sockets

POPA3020AA Unit with 3m lead and BS 1363 plug POPB1020AA Unit with 1.5m lead and GST connector POPD1020AA Unit with 1.5m lead and Intersoc-R connector

Wireless charging unit

Qi certified induction charger

1 077580 1000 mA wireless charger for furniture Wireless charging for Qi enabled smartphones and other mobile devices Designed for mounting horizontally into furniture Supplied complete with required accessories for installation into furniture

60


In-desk units and wireless charging unit technical information In-desk units

Wireless charging unit - 1000 mA

Technical characteristics

Technical characteristics

Electrical characteristics

Electrical characteristics

Earthing system

R < 0.05 Ohms

Nominal input voltage

110 - 230 V ~

Resistance to vertical load applied through small surface area

1500 N cover open 3000 N cover closed

Nominal output voltage

5V~

Rated voltage

U 500 V - R > 5 MOhms

Frequency

50 - 60 Hz

Electric strength

2000 V

Maximum input current

150 mA

Protection class

II - low voltage

Maximum output current

1000 mA

Standby consumption

< 0·07 W

Energy efficiency

> 85%

Protection class

II - low voltage

Material: Halogen free material, fire proofed and no propagator of the flame Resistant to corrosion and to temperature changes Finish: Brushed Stainless steel, zamak nickel coating Safety: You must earth the system Cleaning: The exterior should only be cleaned using a damp cloth (avoid contact with the active parts). Do not use abrasive detergent Installation

Climate characteristics Storage temperature : 20°C to +70°C Operating temperature : 0°C to +45°C

108mm

Standards and approvals WPC QI BS EN 62479 ICNIRP

(1)

131mm(1)

1: +/- 1 mm

Mechanical characteristics Impact resistance : IK 08 Resistance to ingress of solid bodies and liquids : • IP 43 • IP 44 for upper part installed on furniture

Minimum distance from to the edges of the furniture: 70 mm

Material characteristics ABS Halogen free UV resistant Self-extinguishing : • 750°C / 30 s for parts made of insulating materials holding live parts in place • 650°C / 30 s for other insulating components

20 mm 15 mm < e < 40 mm

74.8mm

Dimensions

Y

Average charging time for a smartphone equipped with an induction receiver 80% charge : < 2 hrs 100% charge : < 2 hrs 45 mins

142.5mm

120mm

D

Positioning of the fixing supports X

1

2

3

4

All dimensions (mm) are nominal

61


BUSCOM TRUNKING a unique

power & data backbone

Buscom is at the heart of Electrakâ&#x20AC;&#x2122;s lighting control solutions... It provides a flexible and simple alternative to cabled installations.

THE HEART OF YOUR LIGHTING CONTROL SYSTEM Installing a matrix of Buscom trunking creates an accessible power and communications backbone. The backbone can be tapped into at any point to facilitate instant connection to power and control circuits. Buscom incorporates an integral shielded twisted pair, and is suitable for use with any lighting control protocol, including: KNX, LonWorks and DALI.

MODULAR. FLEXIBLE. SIMPLE. Trunking lengths simply push fit together, saving time and money on installation. With cable terminations only required for power and control circuits in the feed unit, Buscom delivers a plug and play solution that allows for future lighting layout changes to be made quickly and efficiently. 62


BUSCOM ADDS A NEW DIMENSION TO LIGHTING BUSBAR

n

n

Buscom extends the unquestionable plug and play advantages from the power circuit to the control circuit. n

This unique system for distributing lighting control signals delivers unrivalled flexibility, regardless of the location of the intelligence... n

ower and communications within P a single trunking system uitable for use with any lighting S control protocol, including: KNX, LonWorks and DALI odular, flexible system which is M quick and simple to install and adapt educed potential points of failure R in comparison with traditional wiring installations

THE INTELLIGENT SOLUTION INTELLIGENCE IN THE PANEL

Lighting control modules located in a central cabinet are connected to the Buscom system via communication circuits. Control signals are then distributed along the trunking run and made available at any tap-off outlet.

INTELLIGENCE IN THE BUSBAR

Integrating lighting control technology into Buscom trunking is particularly effective for DALI control. Each trunking run converts to an individual DALI network into which luminaires can tapin at any point.

INTELLIGENCE IN THE LCU

Lighting control units (LCUs) are mounted onto and plugged into Buscom trunking, providing a hub for multiple luminaires and switching devices to plug into. Buscomâ&#x20AC;&#x2122;s integrated communication bus provides the backbone network to control all devices. Visit www.legrand.co.uk for more information

63


Electrak® 30 2P + E buscom trunking power and communication distribution

CCA3145C

CCA2145C

CCA14RFC

CCA14LFC Dimensions and technical information p. 68-73 Integral communication bus suitable for KNX, Lonworks, DALI protocols, etc. 25 A and 40 A systems IP 4X ingress protection Fast installation (trunking push fits together in seconds). High quality materials

Pack

Cat. Nos. Electrak

30 2P + E with comms

2P + E buscom trunking system with integral communications bus circuit Socket outlets colour coded white Trunking lengths

Pack

Cat. Nos. Electrak

30 2 P + E without comms

2P + E busbar (power only) trunking system Socket outlets colour coded white Trunking lengths

Trunking lengths push fit into each other, and feed units. Trunking lengths can be suspended using the various bracket options

Trunking lengths push fit into each other, and feed units or flexible lengths. Trunking lengths can be surface mounted suspended using the various bracket options

Length Tap-off Weight 25 A (m) outlets (kg)

Length Tap-off Weight 25 A (m) outlets (kg)

1 BBA3145C 3 1 BBA2145C 2

1 CCA3145C 3 1 CCA2145C 2

40 A

6 4·47 4 3·27 6 4·57 4 3·36

C L N PE

Feed units (with comms)

Feed units come with 2 x 25 mm Ø and 2 x 16 mm Ø cable entry holes and single screw cable terminals for power and data Left feed units are supplied with right end stop Right feed units are supplied with left end stop

64

1 BBA14LFC 1 BBA14RFC 1 CCA14LFC 1 CCA14RFC

25 A left 25 A right 40 A left 40 A right

1 BBA3145 3 1 BBA2145 2

1 CCA3145 3 1 CCA2145 2

40 A

6 4·47 4 3·27 6 4·57 4 3·36

Weight (kg)

1·22 1·49 1·27 1·49

L N PE

Feed units (without comms – power only) Feed units come with 2 x 25 mm Ø cable entry holes and single screw cable terminals Left feed units are supplied with right end stop Right feed units are supplied with left end stop Suspended

Suspended

1 BBA14LF 1 BBA14RF 1 CCA14LF 1 CCA14RF

25 A left 25 A right 40 A left 40 A right

Weight (kg)

1·22 1·49 1·27 1·49


Electrak® 32 4P + E (dual circuit) buscom trunking power and communication distribution

CCC3145C

CCC2145C

CCC14RFC

CCC14LFC Dimensions and technical information p. 68-73 Integral communication bus suitable for KNX, Lonworks, DALI protocols, etc. 25 A and 40 A systems IP 4X ingress protection Fast installation (trunking push fits together in seconds). High quality materials

Pack

Cat. Nos. Electrak

32 4P + E (dual circuit) with comms

Pack

Cat. Nos. Electrak

32 4P + E (dual circuit) without comms

Dual circuit buscom trunking system with integral Dual circuit busbar trunking system communications bus circuit Socket outlets colour coded white Socket outlets colour coded white Trunking lengths Trunking lengths Trunking lengths push fit into each other, and Trunking lengths push fit into each other, and feed units. Trunking lengths can be suspended feed units. Trunking lengths can be suspended using the various bracket options using the various bracket options Length Tap-off Weight 25 A (m) outlets (kg) Length Tap-off Weight 25 A (m) outlets (kg) 1 BBC3145 3 6 4·77 1 BBC3145C 3 6 4·77 1 BBC2145 2 4 3·47 L2 C N2 1 BBC2145C 2 4 3·47 L2 40 A L1 N2 N1 40 A 1 CCC3145 3 6 4·97 L1 PE N 1 1 CCC3145C 3 6 4·97 1 CCC2145 2 4 3·61 PE 1 CCC2145C 2 4 3·61

Feed units (with comms)

Feed units come with 2 x 25 mm Ø and 2 x 16 mm Ø cable entry holes and single screw cable terminals for power and data Left feed units are supplied with right end stop Right feed units are supplied with left end stop Suspended

1 BBC14LFC 1 BBC14RFC 1 CCC14LFC 1 CCC14RFC

25 A left 25 A right 40 A left 40 A right

Weight (kg)

1·29 1·52 1·38 1·61

Feed units (without comms – power only) Feed units come with 2 x 25 mm Ø cable entry holes and single screw cable terminals Left feed units are supplied with right end stop Right feed units are supplied with left end stop Suspended

1 BBC14LF 1 BBC14RF 1 CCC14LF 1 CCC14RF

25 A left 25 A right 40 A left 40 A right

Weight (kg)

1·29 1·52 1·38 1·61

For the full Buscom range please see the Lightrak lighting control catalogue, visit www.legrand.co.uk/downloads

65


Electrak® buscom trunking tap-offs power and communication distribution

DDJ45 DDJ45C

DDK4F

Dimensions and technical information p. 68-73

Pack

Cat. Nos.

Tap-off units with comms

Pack

Cat. Nos. Tap-off

units without comms (power only)

Tap-offs with comms can only be plugged into outlets that have the comms facility 16 A unfused tap-off units Pre-wired tap-off units to pick up L1+N1 or L2+N2, colour coded white

Power only tap-offs can plug into any tap-off outlet 16 A unfused tap-off units Pre-wired tap-off units to pick up L1+N1 or L2+N2, colour coded white

1 1 1 1

DDE43C 3 L1 + N1 DDE45C 5 DDJ43C 3 L2 + N2 DDJ45C 5

1 1 1 1

Length Fixed Weight (m) polarity (kg)

0·5 0·6 0·5 0·6

1 1 1 1

DDE43 3 L1 + N1 DDE45 5 DDJ43 3 L2 + N2 DDJ45 5

13 A fused tap-off units re-wired tap-off units to pick up L1+N1 or L2+N2, P supplied with BS 1362 fuse, colour coded white Length Fixed Weight (m) polarity (kg)

DDE43FC 3 L1 + N1 DDE45FC 5 DDJ43FC 3 L2 + N2 DDJ45FC 5

0·5 0·6 0·5 0·6

1 1 1 1

Length Fixed Weight (m) polarity (kg)

0·5 0·6 0·5 0·6

13 A fused tap-off units re-wired tap-off units to pick up L1+N1 or L2+N2, P supplied with BS 1362 fuse, colour coded white Length Fixed Weight (m) polarity (kg)

DDE43F 3 L1 + N1 DDE45F 5 DDJ43F 3 L2 + N2 DDJ45F 5

0·5 0·6 0·5 0·6

Tap-off units without comms – rewirable 16 A unfused tap-off units Rewirable tap-off units to pick up required circuit, colour coded white, can plug into any tap-off outlet

1 1

DDF4 DDK4

Fixed Weight polarity (kg)

L1 + N1 L2 + N2

0·14 0·14

13 A fused tap-off units Rewirable tap-off units to pick up required circuit, supplied with BS 1362 fuse, colour coded white, can plug into any tap-off outlet

66

1 1

DDF4F DDK4F

Fixed Weight polarity (kg)

L1 + N1 L2 + N2

0·14 0·14


ElectrakÂŽ buscom trunking accessories fixings and ancillary items

EEC348

EEC356

EEB340

EEB344

EEA308

EEA312

EEA328

EEA324

EEC352

EEC364

Dimensions and technical information p. 68-73 Brackets are manufactured from robust galvanised steel, ensuring that the entire installation can be expected to stand up to all normal site conditions

Pack

Cat. Nos. Fixings

Pack

1

EEA308

Trunking suspended fixing bracket

1

1

EEA312 Trunking suspended fixing bracket c/w cable duct stirrup. Used when running cable duct on top of buscom trunking

EEC356 2 m empty length for adjusting the length at the end of a run (to be cut)

1

EEC364 Joint sleeve is used if load is hung off trunking joint or near when joint is centre of a fixing span

1

EEA324

1

EEC366

Left hand end stop spare

1

EEA328 Luminaire 45 mm edge suspension fixing bracket (clip on)

1

EEC368

Right hand end stop spare

1

EEB340

1

EEB344 Closed ring on luminaire

1

EEC348 Cable duct 3 m long x 50 mm(w) x 13 mm(h)

1

EEC357

Joint bracket cable duct

1

EEC352

Cable duct fixing bracket

Luminaire suspension fixing bracket

Cat. Nos. Ancillary

items

Open hook luminaire suspended bracket

For the full Buscom range please see the Lightrak lighting control catalogue, visit www.legrand.co.uk/downloads

67


Electrak® buscom trunking technical information n Standards

Electrical test data

ASTA approved to BS EN 61439-6 Designed to meet the requirements of BS EN 61534-22 : 2014 Manufactured within an approved ISO 9001 : 2015 and ISO 14001 : 2015 Assessed Quality Assurance Certificate No. 10679 Electrak Buscom fully complies with the requirements of BS 7671 : 2018

25 A

Derating factor for Electrak 32 single sided Rated operational voltage (Ue) Rated insulation voltage (Ui) Frequency (f) Rated impulse withstand voltage Busbar resistance (R20) Resistance (R1) Impedance (Z1) Reactance (X1) Protective conductor

40 A

UOM

– 0·8 – 230/400 230/400 V 500 500 V 50 50 Hz 4·0 4·0 KV 3·9 2·7 mΩ/m 4·2 3·0 mΩ/m 4·8 3·4 mΩ/m 2·5 1·6 mΩ/m 1·5 1·5 mΩ/m

± ±

n Buscom trunking options

• L2 • N2 • L • L1 • N • N1 PE PE

Volt drops

Communication bus

Electrak buscom trunking can be used with Electrak’s cost effective lighting control system, Lightrak KNX, or any other systems using control protocols such as KNX, Lonworks, DALI, etc. Electrak’s overhead trunking couples high quality engineering with rigidity of design, and provides power for a variety of applications including lighting, heating and ventilation. The robust easy fix modular system permits loads to be suspended directly from the trunking using Electrak’s various fixing brackets Push fit connection keeps installation costs to a minimum Track lengths simply push fit together

25 A

40 A

UOM

9·0 3·0 22·0 52·0

6·0 2·4 22·0 52·0

mV/A/m mV/A mV/A mV/A

25 A

40 A

UOM

3·0 1·5 2·4 23·0 53·0 16·0 1·0 1·5 35·0

mΩ/m mΩ/m mΩ mΩ mΩ KA KA KA ˚C

25 A

40 A

UOM

2-6 4·0 6·0 1·5 1·5 1·5 16·0 25·0 16·0 4 X

2-6 6·0 16·0 1·5 1·5 1·5 16·0 25·0 16·0 4 X

– mm2 mm2 mm2 mm2 mm2 mmØ mmØ mmØ –

Live and neutral : busbars (R1+R2) Feed unit Tap-off 0·8 m Tap-off 2·0 m Earth fault loop

Impedance : busbar Earth housing Feed unit Tap-off 0·8m Tap-off 2·0m Rated conditional short-circuit current (Icc) Rated short time withstand current (Icw) at 1 sec Rated peak short-circuit current (Ipk) Ambient temperature Mechanical data Number of conductors Busbar conductor cross-sectional area Cable terminal capacity Cable terminal capacity bus Tap-off cable 16 A Tap-off cable 13 A fused Tap-off entry Feed unit entry holes power Feed unit entry holes bus IP rating

4·5 1·5 2·4 23·0 53·0 16·0 0·65 0·975 35·0

Direct protection by enclosure. Indirect protection by protective circuit

n Feed units 25 A rated - max. conductor size 6 mm2 40 A rated - max. conductor size 16 mm2 IP 4X galvanised steel

2 pole + earth + comms

Comms bus Max. conductor size 1·5 mm2 Red + Black All dimensions (mm) are nominal

68


Electrak® buscom trunking technical data

Communication control circuit Type Construction Insulation - conductor Sheath

Bus cable (LSOH) Sheathed 0·5 mm2 copper twisted pair Flame retardant low emission HCL LSOH material

Rated insulation voltage (Ui) (between power circuit and bus)

500 V

Max. bus operating voltage Max. bus operating current Max. conductor resistance (@20˚C) Max. mutual capacitance Material specifications Buscom trunking housing Busbars Busbar insulator Trunking connector / tap-off entry box / cable connector Tap-off housing Trunking connector blades / tap-off blades Feed unit IP 4X Feed unit IP 54 Flexible length conduit Feed unit terminals / earth block Brackets 13 A tap-off, fuse

50 V 0·65 A 73·2 Ω/km 100 nf/km Galvanised steel High conductivity copper Flame retardant LSOH to BS 7211 Flame retardant polycarbonate Flame retardant polycarbonate Copper Galvanised steel ABS Flame retardant LSOH nylon Brass Galvanised steel To BS 1362, ASTA approved

Durability Electrak power and communications distribution systems are well designed and extremely robust. They can be expected to stand up to all normal site conditions. Electrak Buscom has been short circuit strength tested by ASTA Earth fault loop impedance BS 7671 : 2018 require accurate determination of the total earth loop impedance, which must be sufficiently low to allow the protective device to operate within the specified time, which for socket outlets is 0·4 seconds The values relevant to Electrak Buscom for calculating the earth fault loop impedance are shown in the electrical test data table, see opposite Buscom trunking rating in ambient temperatures Average ambient air temperature Rating factor (K1)

25˚C

30˚C

35˚C

40˚C

45˚C

50˚C

1·1

1·05

1

0·95

0·90

0·85

For ambient temperatures other than 35˚C apply the multiplier factor K1 to the rated current Buscom trunking mechanical loading For point loads and evenly distributed loads the maximum weight that can be supported is given below Maximum loading for suspended buscom trunking Fixing distance (m)

1·5

2

2·5

3

3·5

4

Max. point load (deflection = 1/500 x span) (Kg)

20

17

13

12

9

7

Max. distributed load (deflection = 1/500 x span) (Kg)

33

28

22

20

15

12

Max. point load (deflection = 1/350 x span) (Kg)

33

24

18

16

10

9

Max. distributed load (deflection = 1/350 x span) (Kg)

55

40

30

26

16

15

Notes 1. Where trunking joints occur in the middle of the suspension span, and weight is to be suspended from that point, it is recommened to use a strenghting bracket EEC364 over the joint to stop deflection 2. I f the load requirements exceed the above figures, please contact us on +44 (0) 370 608 9020 For design information and technical specification, please contact us on +44 (0) 370 608 9020 Suspension rods and fixings should be of suitable size to carry the weight of both the track and suspended load

All dimensions (mm) are nominal

69


Electrak® buscom trunking dimensions n Fixing dimensions Buscom trunking 3 m 0·5 mspacings outlet spacings 0·5 m outlet 220

195·5 195·5 220

500

3 000 3 000 500

500

500

500

500

500

Buscom trunking 2 m

195·5 195·5 220

500

500

2 000 2 000 500

500

500

500

45

45

32

32

304·5 304·5

500

57

Suspended

Feed unit – left

Feed unit – right

57

209

308

209 517

220

220

All dimensions (mm) are nominal

70

220

End stop – left

10

320

320

209

220 429

517

10

feed unit Single sided system 2 x 16 Ø2 x 16 Ø

57

308

End stop – right

304·5 304·5

Buscom trunking end view

0·5 mspacings outlet spacings 0·5 m outlet 220

500

500

429

209

2 x 25 Ø2 x 25 Ø 52

52

57


13

13

8·5 Ø

108

12

35

1

8·5 Ø 50 8·5 Ø

59

12 95

95

57

8·5 Ø

38

8·5 Ø

130

38

141

7Ø

21 141

82 7Ø

7Ø

163 163

57

7·5

92

60

30

107

1

1

8·5 Ø

125

38 15

M5

8·5 Ø

38

8·5 Ø

77

59

8·5 Ø

70

82

70 Ø 8·5

35

70 13 8·5

39

35

68

53·5

70 6Ø

6 Ø 96

6Ø

30

78

53·5 13

M5

78

6Ø

6Ø 30

Fuse holder 136

6Ø 6 8·5 Ø– 33 mm deep Pre-wired tap-offs 30

78

6Ø

6Ø

39

6Ø 30

78 68

68

96

68

136

Rewirable and phase selection tap-offs – 35 mm deep 96

8·5

39

6Ø

136

68 6Ø 30

78

136

53·5

53·5

70

68

Fuse holder

68

8·5

8·5 6Ø

35

Tap-off Fuse holder

39

35

M5

Fuse holder

39 6Ø

39

68

53·5

6Ø

68

35

68

6Ø

53·5

13

6Ø

70

6Ø

8·5

8·5

96

78

21 Fuse holder

M5

6Ø

Fused tap-off

35

M5

70 70

6Ø 60

70 6 Ø70 60

70

60

68

Fuse holder 39 35

30

38

8·5 Ø

96

70

Tap-off 96 fuse removal M5 M5

21

6Ø 35

Tap-off fuse removal

6Ø 60

M5

Fuse holder 136

8.5 Ø

30 68

fuse removal

Cat. No. EEB340 Open hook

Tap-off 68 fuse removal

30

60

70

70

21 6 Ø

30 30

13

59

59

30

70

6Ø

60

70

12

M5

6Ø

Tap-off fuse removal 21

8·5

12

8·5 Ø

Cat. No.21EEB344 Closed ring hook

35

13 68

8.5 Ø

22

21

30

53·5

0

8·5 Ø

35 78

8.5 Ø

8·5 Ø

6 Ø 8.5 Ø 22

12

8·5 Ø

78

68

13

95

39

38

7

8·5 Ø

12

53·5

108 130 99·7 125 94·5 108

125

13 130 70

22

8.5 Ø

8.5 Ø

12

8·5 Ø

13

6Ø

39

35

70

388·5 Ø

38

50

35

22

108

125

8·5 Ø 12

Ø

8·5 Ø

12

59

95

38 Ø 8·5 82 77

38

12

13

M5

59

21

21

94·5

99·7

130

M5

82 Cat. No. Cable fixing 82 EEC352 21 duct21 bracket

7Ø

50

8·5 Ø

22

2

59

99·7

38

6Ø

12

12

7Ø

57

82

6Ø 60

21

70

13

7Ø

141

163

7·5 59

M5

30

92

70

77

95

35

13 107

35

12

8·5 Ø

30

M5

94·5

99·7

38

70

M5 Cat. No. EEA328 Luminaire 45 mm edge suspension fixing bracket

82

35

21

82

50

94·5

77

M5

8.5 Ø

8·5 Ø

38

Cat. No. EEA312 Suspended trunking13 8·5 Ø fixing bracket cable duct stirrup

22

12

50

M5

70

70

82

8·5 Ø 57

35

12

108

7Ø

12

125

141

8·5 Ø

70 70

7Ø

M5

21

13

7·5

8·5 Ø

13 82 13

59

92

163

108 60

125

130

38

30

12

15 7Ø

77

82 8·5 Ø

99·7

7·5

21

77

35

8·5 Ø 107

38

82

12

Cat. No. EEA324 Luminaire suspended fixing bracket 50 50

21

130 95

7Ø

21 8·5 Ø

94·5 95

82

38

141

0

82

8·5 Ø trunking

163

Cat. No. EEA308 fixing bracket 57

12

108

21

82 38 Suspended

125

7Ø 130

7Ø

6Ø

78

96

6Ø 30

30

136

All dimensions (mm) are nominal

71


ElectrakÂŽ buscom trunking installation n Design and installation Electrak Buscom trunking system comprises continuous lengths of galvanised steel trunking available in 2 m and 3 m lengths with integral connectors and regular tap-off outlets Each trunking run commences with a feed unit for electrical and comms bus cable termination. The connection between the trunking, the feed unit and subsequent trunking lengths is push fit and requires no tools to terminate the connection or ensure good earthing. Each complete track End stop run is finished with an end stop all trunking parts push together The system fit is supplied with IP 4X ingress protection, fully factory tested and ASTA approved to BS EN 61439-6 : 2011 and is designed to meet the requirements of BS EN 61534-22 : 2014 1 To install - push fit parts together. End stop 2Push To take apart - use a screwdriver to depress the locking catch. fit connection 1 2 1 To install - push fit parts together

2

To take apart - use a screwdriver to depress the locking catch

2

1

1

2 Left feed unit Busbar trunking lengths

1

2

Left feed unit

2

2

1

Buscom trunking lengths

2

1

1

2Push in

to release

1

Push in to release

Considerations before installation Calculate the distance between fixing brackets - the maximum fixing distance should not exceed 4 m. If loads are to be hung, please consult loading charts on page 69. The maximum buscom trunking weight is 2 kg/m When fixing brackets to drop rods or surfaces, see mounting details below Suspended trunking fixing brackets

Cable duct clips into bracket Cable duct clips into bracket EEA312 When using cable duct EEA312 alongusing trunking When cable duct along trunking

EEA308

EEC352 Cable duct bracket EEC352 Cable duct bracket

EEB344

2

1 EEA304

All dimensions (mm) are nominal

72

57mm Edge Surface Fixing Bracket


Luminaire mounting fixing brackets : suspended trunking

EEA324 Luminaire fixing brackets

EEA328 45 mm Edge luminaire fixing brackets (maximum load 5 kg)

All dimensions (mm) are nominal

73


CONTACT DETAILS Quotations and Technical Support: Legrand Electric Ltd. Great King Street North, Birmingham, B19 2LF Tel: +44 (0) 370 608 9020 Fax: +44 (0) 345 600 6760 E-mail: powersales.uk@legrand.co.uk Customer Services: Legrand Electric Ltd. No. 1 Industrial Estate Medmonsley Road, Consett County Durham, DH8 6SR Tel: +44 (0) 345 605 4333 Fax: +44 (0) 345 600 6366 E-mail: powersales.uk@legrand.co.uk Republic of Ireland: Tel: 01 295 9673 Fax: 01 295 4671 E-mail: powersales.uk@legrand.co.uk

FOLLOW US AT www.legrand.co.uk www.legrand.ie www.youtube.com/legrandtvuk www.voltimum.co.uk www.voltimum.ie www.twitter.com/legranduk

Head office (UK and Ireland): Legrand Electric Limited Great King Street North, Birmingham, B19 2LF Tel: +44 (0) 370 608 9000 Fax: +44 (0) 370 608 9004 Website: www.legrand.co.uk

In accordance with its policy of continuous improvement, the Company reserves the right to change specifications and designs without notice. All illustrations, descriptions, dimensions and weights in this catalogue are for guidance and cannot be held binding on the Company. All contents and design presentation included in this publication are Š Legrand Electric Limited. All rights reserved. 2019

This document is printed on sustainably sourced paper. Please recycle.

The Legrand logo is a registered trademark of the Legrand group of companies.

999552 Electrak powering the workplace 01.2019.5k

www.linkedin.com/ company/legranduk


Turn static files into dynamic content formats.

Create a flipbook
legrand-electrak by ACEC Distributors Ltd - Issuu