POWERING THE WORKPLACE PRODUCT GUIDE
POWERED BY SPECIALISTS
Global strength built on local knowledge Legrand is the global specialist in electrical and digital building infrastructures. Innovation is the driving force behind its development. With an increasing investment in research and development (circa 5% of sales) and more than 4,000 active patents, the Legrand Group is focused on maintaining a high rate of new product launches that present innovative solutions to the market.
CORPORATE SOCIAL RESPONSIBILITY
LEGRAND’S POWER DISTRIBUTION BUSINESS UNIT
Legrand’s CSR roadmap is a natural extension to the governance and sustainable development approach in which the company has been engaged for many years. The CSR roadmap firmly asserts Legrand’s ongoing commitment to sustainable development.
From Zucchini transformers, through high power distribution and rising main busbar to Electrak powertrack, desk modules and lighting control, Legrand’s power distribution business unit provides market leading solutions to the increasing demands of today’s buildings.
Respect human rights and communities Ensure health, safety and well-being Develop skills Promote equal opportunity and diversity
Provide sustainable solutions Ensure sustainable procurement Act ethically
Mitigate climate change Innovate for the circular economy Prevent pollution
POWERTRACK Overview Ordering information Technical information
6 8 18
FLOOR BOXES
CONTENTS
Electrak, part of the Legrand Group in the UK, is a leading manufacturer of power distribution and lighting control solutions. It's powertrack, floor boxes and grommets, desk modules and lighting control ranges are installed in high specification offices around the world.
Overview 24 Ordering information 26 Technical information 33
FLOOR GROMMETS
Overview 34 Ordering information 36 Technical information 37
INTERSOC-R
Overview 38 Ordering information 42 Technical information 44
ON-DESK
Overview 48 Ordering information 52 Technical information 56
IN-DESK Overview 58 Ordering information 60 Technical information 61
BUSCOM TRUNKING Overview Ordering information Technical information
62 64 68 1
ELECTRAK
ÂŽ
the specialist in power distribution throughout the
workplace
Electrak, a brand of the Legrand Group in the UK, is a leading name in power distribution and lighting control solutions. Electrak busbar systems, floor boxes, floor grommets, desk modules and lighting control ranges are installed in high specification offices around the world.
2
Powering the
workplace UNDERFLOOR POWER Electrak’s powertrack system is perfect for supplying underfloor power in cavity floor installations. With minimal parts, push-fit assembly and a complementary range of floor boxes, this flexible, easy-to-install system can be reconfigured as office layouts evolve.
POWERTRACK See page 6
CAVITY FLOOR BOXES See page 24
WORKSTATION POWER Electrak’s access grommets provide the gateway for power to feed from the underfloor powertrack network to the workstation, where all desk power requirements are met with our new range of desk modules, Intersoc-R, On-desk and In-desk.
FLOOR GROMMETS See page 34
INTERSOC-R See page 38
ON-DESK & IN-DESK See pages 48 & 58
FULLY ADDRESSABLE LIGHTING CONTROL Designed to work in harmony with Buscom trunking, Lightrak lighting control offers high-end sophistication with unbeatable flexibility and speed of installation.
BUSCOM power and data backbone See page 62
LIGHTRAK lighting control system Visit: www.legrand.co.uk
3
ELECTRAK
ÂŽ
UK manufacturing
Global recognition
OVER 30 YEARS' EXPERIENCE Legrand’s cost-effective Electrak systems have been designed and manufactured to distribute power and data reliably and safely throughout the workplace. The original underfloor busbar system, invented by Electrak in the 1980s, sets the benchmark for flexible power distribution.
INDUSTRY EXPERTS As part of its ongoing commitment to research and development, Legrand continually evolves its product ranges to ensure it develops the best and most innovative solutions available on the market. Legrand takes pride in its enviable reputation for market leading customer service, industry knowledge and product expertise. 4
TRUSTED
THROUGHOUT THE UK AND ACROSS THE WORLD
UNITED KINGDOM
MIDDLE EAST & INDIA
ASIA PACIFIC
n
Morgan Stanley, Canary Wharf
n
ADMA-OPCO HQ, Dubai
n
Media City, Manchester
n
Internet City, Dubai
n
JP Morgan, Canary Wharf
n
Burjuman Centre, Dubai
n
RBS, Edinburgh
n
ADIC/Al Bahr Towers, Abu Dhabi
Bridgewater Place, Leeds
n
Al Dar HQ, Abu Dhabi
n
n
Network Rail, Nationwide
n
Central Bank of Kuwait
n
n n
Swiss Re, City of London
n
Ministry of Education, Kuwait
n
Amazon, Swansea
n
PIFFS Aridya, Kuwait
UBS Bank, IFC II, Hong Kong
n
n
Heathrow Airport, London
n
PAAET, Kuwait
JP Morgan, Hong Kong
n
n
n
Snow Hill, Birmingham
n
Qatar News Agency
n
Barclays Capital, Canary Wharf
n
Barclays, Chennai, India
n
n
Temple Back, Bristol
n
Barclays, Pune, India
n
n
Barclays, Andheri, India
n
Barclays, Mumbai, India
n
Standard Chartered Bank, City of London
n
London Underground
n
BBC, White City
RBS, Delhi, India
n
n
n
Mann Island, Liverpool
Fidelity, Delhi, India
QUALITY ASSURED UK MANUFACTURING With its Electrak ranges manufactured from its UK base situated in the North East of England, Legrand can provide a rapid production response and adapt to ever-changing project demands. Having total production control also helps ensure our quality meets the highest standards.
n
n
n
n n
Deutsche Bank, ICC I, Hong Kong Customs Headquarters, North Point, Hong Kong Citi Bank Tower, Hong Kong Macquarie Bank, IFC I, Hong Kong
Nomura Bank, Marina Bay, Singapore Credit Suisse, Singapore ABN Amro, One Raffles Quay, Singapore RBS, One George Street, Singapore Barclays Capital, Shanghai Standard Chartered Bank, Shanghai
BUILDING INFORMATION MODELLING As part of Legrand’s ongoing commitment to supporting construction, we have integrated a number of ranges into the BIM environment to assist all areas of project activity, from design and construction through to facilities management and beyond. Autodesk Revit files are now available for Electrak powertrack, floor boxes and Buscom trunking. Download Revit files at: www.legrand.co.uk
5
POWERTRACK adaptable, reliable adaptable, reliable
underfloor power 6
THE INDUSTRY STANDARD IN UNDERFLOOR POWER Electrak powertrack / underfloor busbar is perfect for cavity floor installations. With minimal parts, push-fit assembly and a complementary range of floor boxes and grommets, this flexible, easy-to-install system can be reconfigured as office layouts evolve. The system consists of continuous lengths of track which are fed via a feed unit and can be installed in floor voids as low as 48mm.
n n
n
n
n
n
63 A rated, IP 40 protection Available in five versions: single phase, clean earth, dual circuit, three phase and auxiliary earth inned busbar version available for T use within Abu Dhabi (see page 15) Available in 1.2m, 1.8m, 2.4m and 3.6m lengths Tap-off outlets are located at every 300 or 600mm pitch Floor mountable (stand-off brackets also available)
Integral track connector plugs into feed unit
Lengths simply push-fit together
Integral fixing brackets for rapid installation
Tap-offs plug into shuttered socket outlets and lock onto track body 7
Electrak® powertrack / underfloor busbar system selection chart
Description
Length (m)
Track lengths with 300 mm socket centres 4 outlets
1·2
6 outlets
1·8
8 outlets
2·4
12 outlets
3·6
Track feeds –
Excluding cables and conduit
–
Flexible metal conduit
1·2
Flexible metal conduit
2·4
Standard tap-off / auxiliary earth tap-off 32 A unfused 16 mm Ø L, N, PE 13 A fused 16 mm Ø L, N, PE 13 A 543·7 fused 16 mm Ø L, N, PE
3 5 3 5 3 5
Low noise / clean earth tap-off 32 A unfused 16 mm Ø CE, L, N, PE 13 A fused 16 mm Ø CE, L, N, PE 13 A 543·7 fused 16 mm Ø CE, L, N, PE
3 5 3 5 3 5
Dual circuit tap-off 3 32 A unfused 20 mm Ø CE, L1, N1 L2, N2, PE 5 3 phase tap-off 32 A 415 V 3 phase 20 mm Ø L1, L2, L3, N, PE 32 A L1 unfused reconfigurable live pin 16 mm Ø L1, N, PE 32 A L2 unfused reconfigurable live pin 16 mm Ø L2, N, PE 32 A L3 unfused reconfigurable live pin 16 mm Ø L3, N, PE
Key code / Busbar arrangement
8
3 5 3 5 3 5 3 5
ELECTRAK 24 Standard system (white)
ELECTRAK 25 Low noise / clean earth system (green)
ELECTRAK 26 Dual circuit system (dark green)
ELECTRAK 27 3 phase system (grey)
ELECTRAK 28 Auxiliary earth system (red)
DA1123
JA2123
KA3123
NA4123
YA5123
DA1183
JA2183
KA3183
NA4183
YA5183
DA1243
JA2243
KA3243
NA4243
YA5243
DA1363
JA2363
KA3363
NA4363
YA5363
DF1010
JF2010
KF3010
NF4010
YF5010
DW1000
JW2000
KW3000
NW4000
YW5000
DW1010
JW2010
KW3010
NW4010
YW5010
DW1020
JW2020
KW3020
NW4020
YW5020
DP1332
–
DP1332
–
YP5332
DP1532
–
DP1532
–
YP5532
DP1313
–
DP1313
–
YP5313
DP1513
–
DP1513
–
YP5513
DP1327
–
DP1327
–
YP5327
DP1527
–
DP1527
–
YP5527
–
JP2332
JP2332
–
–
–
JP2532
JP2532
–
–
–
JP2313
JP2313
–
–
–
JP2513
JP2513
–
–
–
JP2327
JP2327
–
–
–
JP2527
JP2527
–
–
–
–
KP3328
–
–
–
–
KP3528
–
–
– – – – – – – –
– – – – – – – –
– – – – – – – –
NZ4331 NZ4531 NP43321 NP45321 NP43021 NP45021 NP43031 NP45031
– – – – – – – –
PE
N2 L2
PE CE N1 L1
PE CE N1 L1 N2 L2
PE N L1 L2 L3
PE N1 L1
1 : All NP tap-offs are reconfigurable between L1, L2 or L3 for 3 phase track
9
Electrak® 24 powertrack / underfloor busbar system standard system (white)
DF1010
- - -/
---
DW1010
DA1123
DP1332
Selection charts p. 8-9 Dimensions and technical information p. 18-23 Approved to ASTA Standard 138 and ISO 9001 : 2015 Conforms to BS EN 61534-22 : 2014. Fully complies with the requirements of BS 7671 : 2018 A compact system that can be installed in floor voids as low as 48 mm
Pack
Cat. Nos.
Track system components
Electrak 24 standard track lengths
Tap-off length is determined by the cable and not the conduit length, e.g. a 3 m tap-off has 3 m of cable and 2·6 m of flexible metal conduit1 Tap-off units in excess of 3 m should only be used if they contain a fuse or if the powertrack is protected by a protective device not exceeding 32 A
Track lengths fit together using the integral connectors on each length Track lengths should always be secured using the integral floor fixing brackets 300 mm socket centres 1 DA1123 1·2 m, 4 outlets, 2 floor fixing brackets 1 DA1183 1·8 m, 6 outlets, 2 floor fixing brackets 1 DA1243 2·4 m, 8 outlets, 2 floor fixing brackets 1 DA1363 3·6 m, 12 outlets, 3 floor fixing brackets
1
Track feed unit
DF1010 With one 25 mm diameter hole suitable for MICC, armoured cables or single core cables in conduit
Flexible interlinks
Can be used to overcome obstructions or as corners where required 1 DW1000 Excluding cables and conduit 1 DW1010 1·2 m flexible metal conduit 1 DW1020 2·4 m flexible metal conduit Special fixing brackets Required when track is raised off surface level Brackets raise track by 21 mm and should be spaced 600 mm apart 1 DZ1210 For fitting under track body and track feed 1 DZ1230 For fitting under integral track connectors
Pack
Cat. Nos. Tap-off
units
32 A unfused - 543·7 high integrity
16 mm Ø‚ L, N, PE 1 DP1332 3 m 1 DP1532 5 m
13 A fused - 543·7 high integrity
16 mm Ø‚ L, N, PE 1 DP1327 3 m 1 DP1527 5 m
13 A fused
16 mm Ø‚ L, N, PE 1 DP1313 3 m 1 DP1513 5 m
Tap-off units specifically for the U.A.E.
To meet the local requirements, these tap-offs contain silver-flashed blades, larger 20 mm Ø conduits and minimum 4 mm2 conductors
32 A unfused - 543·7 high integrity
L (red), N (black), PE (green/yellow) 1 DP1332R 3 m U.A.E. 1 DP1532R 5 m U.A.E.
13 A fused - 543·7 high integrity
L (red), N (black), PE (green/yellow) 1 DP1314R 3 m U.A.E. 1 DP1514R 5 m U.A.E.
1 : Tap-offs are supplied as standard with flexible metal conduit For alternative wiring solutions, contact us on +44 (0) 370 608 9020
10
Electrak® 25 powertrack / underfloor busbar system low noise / clean earth system (green)
JF2010
- - -/
---
JW2010
JA2123
JP2332
Selection charts p. 8-9 Dimensions and technical information p. 18-23 Approved to ASTA Standard 138 and ISO 9001 : 2015 Conforms to BS EN 61534-22 : 2014. Fully complies with the requirements of BS 7671 : 2018 A compact system that can be installed in floor voids as low as 48 mm
Pack
Cat. Nos.
Track system components
Electrak 25 low noise / clean earth track lengths
Tap-off length is determined by the cable and not the conduit length, e.g. a 3 m tap-off has 3 m of cable and 2·6 m of flexible metal conduit1 Tap-off units in excess of 3 m should only be used if they contain a fuse or if the powertrack is protected by a protective device not exceeding 32 A
Track lengths fit together using the integral connectors on each length Track lengths should always be secured using the integral floor fixing brackets 300 mm socket centres 1 JA2123 1·2 m, 4 outlets, 2 floor fixing brackets 1 JA2183 1·8 m, 6 outlets, 2 floor fixing brackets 1 JA2243 2·4 m, 8 outlets, 2 floor fixing brackets 1 JA2363 3·6 m, 12 outlets, 3 floor fixing brackets
1
Track feed unit
JF2010 With one 25 mm diameter hole suitable for MICC, armoured cables or single core cables in conduit
Flexible interlinks
Can be used to overcome obstructions or as corners where required 1 JW2000 Excluding cables and conduit 1 JW2010 1·2 m flexible metal conduit 1 JW2020 2·4 m flexible metal conduit
Pack
Cat. Nos. Tap-off
units
32 A unfused - 543·7 high integrity
16 mm Ø‚ CE, L, N, PE 1 JP2332 3 m 1 JP2532 5 m
13 A fused - 543·7 high integrity
16 mm Ø‚ CE, L, N, PE 1 JP2327 3 m 1 JP2527 5 m
13 A fused
16 mm Ø‚ CE, L, N, PE 1 JP2313 3 m 1 JP2513 5 m
Special fixing brackets Required when track is raised off surface level Brackets raise track by 21 mm and should be spaced 600 mm apart 1 DZ1210 For fitting under track body and track feed 1 DZ1230 For fitting under integral track connectors
1 : Tap-offs are supplied as standard with flexible metal conduit For alternative wiring solutions, contact us on +44 (0) 370 608 9020
11
Electrak® 26 powertrack / underfloor busbar system dual circuit system (dark green)
KF3010
- - -/
---
KW3010
KA3123
KP3328
Selection charts p. 8-9 Dimensions and technical information p. 18-23 Approved to ASTA Standard 138 and ISO 9001 : 2015 Conforms to BS EN 61534-22 : 2014. Fully complies with the requirements of BS 7671 : 2018 A compact system that can be installed in floor voids as low as 48 mm
Pack
Cat. Nos.
Track system components
The dual powertrack system has both standard and low noise / clean earth systems incorporated
Electrak 26 dual circuit track lengths
Track lengths fit together using the integral connectors on each length Track lengths should always be secured using the integral floor fixing brackets 300 mm socket centres 1 KA3123 1·2 m, 4 outlets, 2 floor fixing brackets 1 KA3183 1·8 m, 6 outlets, 2 floor fixing brackets 1 KA3243 2·4 m, 8 outlets, 2 floor fixing brackets 1 KA3363 3·6 m, 12 outlets, 3 floor fixing brackets
1
Track feed unit
KF3010 With two 25 mm diameter holes suitable for MICC, armoured cables or single core cables in conduit
Flexible interlinks
Can be used to overcome obstructions or as corners where required 1 KW3000 Excluding cables and conduit 1 KW3010 1·2 m flexible metal conduit 1 KW3020 2·4 m flexible metal conduit Special fixing brackets Required when track is raised off surface level Brackets raise track by 21 mm and should be spaced 600 mm apart 1 DZ1210 For fitting under track body and track feed 1 DZ1230 For fitting under integral track connectors
Pack
Cat. Nos. Tap-off
units
Tap-off length is determined by the cable and not the conduit length, e.g. a 3 m tap-off has 3 m of cable and 2·6 m of flexible metal conduit1 Tap-off units in excess of 3 m should only be used if they contain a fuse or if the powertrack is protected by a protective device not exceeding 32 A
Standard 32 A unfused - 543·7 high integrity
16 mm Ø‚ L, N, PE 1 DP1332 3 m 1 DP1532 5 m
Standard 13 A fused - 543·7 high integrity
16 mm Ø‚ L, N, PE 1 DP1327 3 m 1 DP1527 5 m
Standard 13 A fused
16 mm Ø‚ L, N, PE 1 DP1313 3 m 1 DP1513 5 m Low noise / clean earth 32 A unfused 543·7 high integrity 16 mm Ø‚ CE, L, N, PE 1 JP2332 3 m 1 JP2532 5 m Low noise / clean earth 13 A fused 543·7 high integrity 16 mm Ø‚ CE, L, N, PE 1 JP2327 3 m 1 JP2527 5 m
Low noise / clean earth 13 A fused
16 mm Ø‚ CE, L, N, PE 1 JP2313 3 m 1 JP2513 5 m
Dual circuit 32 A unfused - 543·7 high integrity
20 mm Ø‚ CE, L1, N1, L2, N2,PE 1 KP3328 3 m 1 KP3528 5 m
1 : Tap-offs are supplied as standard with flexible metal conduit For alternative wiring solutions, contact us on +44 (0) 370 608 9020
12
Electrak® 27 powertrack / underfloor busbar system 3 phase system (grey)
NF4010
- - -/
---
NW4010
NA4123
NZ4331
Selection charts p. 8-9 Dimensions and technical information p. 18-23 Approved to ASTA Standard 138 and ISO 9001 : 2015 Conforms to BS EN 61534-22 : 2014. Fully complies with the requirements of BS 7671 : 2018 A compact system that can be installed in floor voids as low as 48 mm
Pack
Cat. Nos.
Track system components
Pack
Electrak 27 3 phase track lengths
Tap-off length is determined by the cable and not the conduit length, e.g. a 3 m tap-off has 3 m of cable and 2·6 m of flexible metal conduit1 Tap-off units in excess of 3 m should only be used if they contain a fuse or if the powertrack is protected by a protective device not exceeding 32 A
Track lengths fit together using the integral connectors on each length Track lengths should always be secured using the integral floor fixing brackets 300 mm socket centres 1 NA4123 1·2 m, 4 outlets, 2 floor fixing brackets 1 NA4183 1·8 m, 6 outlets, 2 floor fixing brackets 1 NA4243 2·4 m, 8 outlets, 2 floor fixing brackets 1 NA4363 3·6 m, 12 outlets, 3 floor fixing brackets
1
Track feed unit
NF4010 With one 25 mm diameter hole suitable for MICC, armoured cables or single core cables in conduit
Flexible interlinks
Can be used to overcome obstructions or as corners where required 1 NW4000 Excluding cables and conduit 1 NW4010 1·2 m flexible metal conduit 1 NW4020 2·4 m flexible metal conduit Special fixing brackets Required when track is raised off surface level Brackets raise track by 21 mm and should be spaced 600 mm apart 1 DZ1210 For fitting under track body and track feed 1 DZ1230 For fitting under integral track connectors
Cat. Nos.
Tap-off units
32 A 415 V 3 phase - 543·7 high integrity
20 mm Ø‚ L1, L2, L3, N, PE 1 NZ4331 3 m 1 NZ4531 5 m
32 A L12 unfused - 543·7 high integrity
Reconfigurable live pin 16 mm Ø‚ L, N, PE 1 NP4332 3 m 1 NP4532 5 m
32 A L22 unfused - 543·7 high integrity
Reconfigurable live pin 16 mm Ø‚ L, N, PE 1 NP4302 3 m 1 NP4502 5 m
32 A L32 unfused - 543·7 high integrity
Reconfigurable live pin 16 mm Ø‚ L, N, PE 1 NP4303 3 m 1 NP4503 5 m
Tap-off units specifically for the U.A.E.
To meet the local requirements, these tap-offs contain silver-flashed blades, larger 20 mm Ø conduits, minimum 4 mm2 conductors and use RYB colour coding for the conductors
1 1 1 1 1 1
32 A unfused - 543·7 high integrity
NP4332R 3 m L1 U.A.E. (R) NP4532R 5 m L1 U.A.E. (R) NP4302Y 3 m L2 U.A.E. (Y) NP4502Y 5 m L2 U.A.E. (Y) NP4303B 3 m L3 U.A.E. (B) NP4503B 5 m L3 U.A.E. (B)
1 : Tap-offs are supplied as standard with flexible metal conduit For alternative wiring solutions, contact us on +44 (0) 370 608 9020 2 : All NP tap-offs are reconfigurable between L1, L2, or L3 for 3 phase track
13
Electrak® 28 powertrack / underfloor busbar system auxiliary earth system (red)
YF5010
- - -/
---
YW5010
YA5123
YP5332
Selection charts p. 8-9 Dimensions and technical information p. 18-23 Approved to ASTA Standard 138 and ISO 9001 : 2015 Conforms to BS EN 61534-22 : 2014. Fully complies with the requirements of BS 7671 : 2018 A compact system that can be installed in floor voids as low as 48 mm
Pack
Cat. Nos.
Track system components
Electrak 28 auxiliary earth track lengths
Tap-off length is determined by the cable and not the conduit length, e.g. a 3 m tap-off has 3 m of cable and 2·6 m of flexible metal conduit1 Tap-off units in excess of 3 m should only be used if they contain a fuse or if the powertrack is protected by a protective device not exceeding 32 A
Track lengths fit together using the integral connectors on each length Track lengths should always be secured using the integral floor fixing brackets 300 mm socket centres 1 YA5123 1·2 m, 4 outlets, 2 floor fixing brackets 1 YA5183 1·8 m, 6 outlets, 2 floor fixing brackets 1 YA5243 2·4 m, 8 outlets, 2 floor fixing brackets 1 YA5363 3·6 m, 12 outlets, 3 floor fixing brackets
1
Track feed unit
YF5010 With one 25 mm diameter hole suitable for MICC, armoured cables or single core cables in conduit
Flexible interlinks
Can be used to overcome obstructions or as corners where required 1 YW5000 Excluding cables and conduit 1 YW5010 1·2 m flexible metal conduit 1 YW5020 2·4 m flexible metal conduit
Pack
Cat. Nos. Tap-off
units
32 A unfused - 543·7 high integrity
16 mm Ø‚ L, N, PE 1 YP5332 3 m 1 YP5532 5 m
13 A fused - 543·7 high integrity
16 mm Ø‚ L, N, PE 1 YP5327 3 m 1 YP5527 5 m
13 A fused
16 mm Ø‚ L, N, PE 1 YP5313 3 m 1 YP5513 5 m
Special fixing brackets Required when track is raised off surface level Brackets raise track by 21 mm and should be spaced 600 mm apart 1 DZ1210 For fitting under track body and track feed 1 DZ1230 For fitting under integral track connectors
1 : Tap-offs are supplied as standard with flexible metal conduit For alternative wiring solutions, contact us on +44 (0) 370 608 9020
14
Electrak
tinned powertrack... Designed to meet local standards
As a specific requirement for use within Abu Dhabi, Legrand has developed a ‘tinned’ busbar which has been designed in line with the guidance for busways outlined by the Abu Dhabi Distribution Company (ADDC), as detailed below.
Guideline For Design, Testing and Installation Of Busways GL.GN.01. Issued by: Abu Dhabi Distribution Co. Low Voltage Switchgear Committee Issue: 2, Revision: 1, effective 01/02/2012 16. Lighting & Small Power Busways & Modular Wiring Lighting & Power Socket bus duct and modular wiring are considered part of building wiring and regulated by the Electricity Wiring Regulation issued by RSB. It shall comply with respective specifications under the Wiring regulation. ADDC LVSGC approves these methods in principle provided that the RSB set aspects are incorporated (like tinning of copper, colour coding etc.).
Electrak 28R tinned tap-offs
Electrak 28R tinned busbar connectors
Appendix 8. Colour identification for cables Conductor
Colour
Non-flexible fixed wiring and all 3 phase cables: Phase 1
Red
Copyright Abu Dhabi Distribution Co.
Phase 2
Yellow
Developed to meet the ADDC requirements for busways, these specially designed ranges see all busbars tinned along their entire length, and all busbar connectors and tap-off blades plated.
Phase 3
Blue
Neutral
Black
Earth conductors
Green / yellow
Guideline For Design, Testing and Installation Of Busways GL.GN.01
Approved to ASTA standard 138 and designed to be in accordance with the requirements of BS EN 61439-6 : 2011 and BS EN 61534-22: 2014 (IEC 61534: 2009).
The Electrical Wiring Regulations 2007 Issued by: The Regulation and Supervision Bureau for the Water, Wastewater and Electricity Sector in the Emirate of Abu Dhabi. Revision 1, January 2009 7.7 Busways, bus ducts and busbar risers 7.7.6 Busways, bus ducts and busbar risers shall have neutral conductors of equal size to the phase conductors and shall have a dedicated Earth Conductor. The use of the metal casing as an earth conductor permitted only for Earth Leakage Protected Installations, and with the prior approval of the Distribution Company.
To meet the local regulations, tap-offs designed for sale within this region are supplied with the following cable colours: Within any single phase system (e.g. Electrak 25R or Electrak 28R) - red (L), black (N) and green/yellow (E). Specifically within the 3 phase Electrak 27 system - L1 tapoffs are red (L), black (N) and green/yellow (E); L2 tap-offs are yellow (L), black (N) and green/yellow (E); L3 tap-offs are blue (L), black (N) and green/yellow (E). Appendix 9. Capacity of conduits and trunking Conduit (mm2)
Diameter of Conduit (mm2) 20
25
32
Maximum number of conductors
1.5
7
12
-
2.5
5
9
12
4.0
3
6
9
The tap-offs contain a maximum of 2 x 4mm2 conductors (excluding earths) housed in a 20mm ø metal flexible conduit.
The Electrical Wiring Regulations 2007 Copyright The Regulation and Supervision Bureau (RSB)
The Electrak powertrack system uses equal size tinned copper busbars for live, neutral and earth conductors to meet with the requirements of The Regulation and Supervision Bureau of the Water, Wastewater and Electricity Sector in the Emirate of Abu Dhabi.
NOTE: When designing installation in
regions with higher ambient temperatures than 35ºC, de-rating factors may need to be applied. Please refer to the table on page 22 for details.
15
Electrak® 25R tinned powertrack / underfloor busbar system low noise / clean earth system (green)
JF2010R
- - -/
---
JW2010R
JA2123R
JP2332R
Dimensions and technical information p. 18-23 Approved to ASTA Standard 138 and ISO 9001 : 2015 Conforms to BS EN 61534-22 : 2014. Fully complies with the requirements of BS 7671 : 2018 A compact system that can be installed in floor voids as low as 48 mm
Pack
Cat. Nos.
Busbar system components
63 A low noise / clean earth busbar lengths
Tap-off length is determined by the cable and not the conduit length, e.g. a 3 m tap-off has 3 m of cable and 2·6 m of flexible metal conduit1 Tap-off units in excess of 3 m should only be used if they contain a fuse or if the busbar run is protected by a protective device not exceeding 32 A
Busbar lengths fit together using the integral connectors on each length Lengths should always be secured using the integral floor fixing brackets 300 mm socket centres 1 JA2123R 1·2 m, 4 outlets, 2 floor fixing brackets 1 JA2183R 1·8 m, 6 outlets, 2 floor fixing brackets 1 JA2243R 2·4 m, 8 outlets, 2 floor fixing brackets 1 JA2363R 3·6 m, 12 outlets, 3 floor fixing brackets
1
Feed unit
JF2010R With one 25 mm diameter hole suitable for MICC, armoured cables or single core cables in conduit
Flexible interlinks
Can be used to overcome obstructions or as corners where required 1 JW2000R Excluding cables and conduit 1 JW2010R 1·2 m flexible metal conduit 1 JW2020R 2·4 m flexible metal conduit
Pack
Cat. Nos. Tap-off
units
32 A unfused - 543·7 high integrity
20 mm Ø‚ CE, L, N, PE (4 mm2) 1 JP2332R 3 m 1 JP2532R 5 m
13 A fused - 543·7 high integrity
20 mm Ø‚ CE, L, N, PE (4 mm2) 1 JP2314R 3 m 1 JP2514R 5 m
Special fixing brackets Required when busbar is raised off surface level Brackets raise the system by 21 mm and should be spaced 600 mm apart 1 DZ1210 For fitting under lengths and feed units 1 DZ1230 For fitting under integral connectors
1 : Tap-offs are supplied as standard with flexible metal conduit For alternative wiring solutions, contact us on +44 (0) 370 608 9020
16
Electrak® 28R tinned powertrack / underfloor busbar system auxiliary earth system (red)
YF5010R
- - -/
---
YW5010R
YA5123R
YP5332R
Dimensions and technical information p. 18-23 Approved to ASTA Standard 138 and ISO 9001 : 2015 Conforms to BS EN 61534-22 : 2014. Fully complies with the requirements of BS 7671 : 2018 A compact system that can be installed in floor voids as low as 48 mm
Pack
Cat. Nos.
Busbar system components
63 A auxiliary earth busbar lengths
Tap-off length is determined by the cable and not the conduit length, e.g. a 3 m tap-off has 3 m of cable and 2·6 m of flexible metal conduit1 Tap-off units in excess of 3 m should only be used if they contain a fuse or if the busbar run is protected by a protective device not exceeding 32 A
Busbar lengths fit together using the integral connectors on each length Lengths should always be secured using the integral floor fixing brackets 300 mm socket centres 1 YA5123R 1·2 m, 4 outlets, 2 floor fixing brackets 1 YA5183R 1·8 m, 6 outlets, 2 floor fixing brackets 1 YA5243R 2·4 m, 8 outlets, 2 floor fixing brackets 1 YA5363R 3·6 m, 12 outlets, 3 floor fixing brackets
1
Feed unit
YF5010R With one 25 mm diameter hole suitable for MICC, armoured cables or single core cables in conduit
Flexible interlinks
Can be used to overcome obstructions or as corners where required 1 YW5000R Excluding cables and conduit 1 YW5010R 1·2 m flexible metal conduit 1 YW5020R 2·4 m flexible metal conduit
Pack
Cat. Nos. Tap-off
units
32 A unfused - 543·7 high integrity
20 mm Ø‚ L, N, PE (4 mm2) 1 YP5332R 3 m 1 YP5532R 5 m
13 A fused - 543·7 high integrity
20 mm Ø‚ L, N, PE (4 mm2) 1 YP5314R 3 m 1 YP5514R 5 m
Special fixing brackets Required when busbar is raised off surface level Brackets raise the system by 21 mm and should be spaced 600 mm apart 1 DZ1210 For fitting under lengths and feed units 1 DZ1230 For fitting under integral connectors
1 : Tap-offs are supplied as standard with flexible metal conduit For alternative wiring solutions, contact us on +44 (0) 370 608 9020
17
Electrak® powertrack / underfloor busbar system design and installation n General installation notes
n Special fixing brackets
Electrak powertrack is a compact system that can be installed in floor voids as low as 48 mm
Electrak special fixing brackets are available to raise the system by 21 mm. Ensure brackets are spaced 600 mm apart and always have support under the integral connectors and feed units. Failure to do so may undermine the integrity of the system
Feed units are provided with one or two 25 mm diameter holes suitable for MICC, armoured cables or single core cables in conduit Track lengths connect together and to feed units using the integral connectors on each length Lengths should always be secured using the integral floor fixing brackets ; three on the 3·6 m length and two on 2·4 m, 1·8 m or 1·2 m lengths
Cat. No. DZ1210 raised off-floor fixing brackets are spaced at 600 mm centres along the busbar run. Also use bottom half of bracket under feed unit and flexible interlink Cat. No. DZ1230 raised off-floor fixing brackets are always used under integral connectors. Busbar is secured to raised brackets using the integral fixing bracket
Access to power is provided along the busbar length by simply plugging tap-off units into shuttered socket outlets. These tap-off units feed all types of conventional floor service outlet boxes or feed workstations directly through the floor via insulated conductors contained in flexible metal or VO rated nylon conduit. When connecting tap-offs directly through the floor via grommet outlets to workstations care must be taken to ensure that the tap-off length is adequate Integral fixing bracket screws to special bracket
The dual system has both standard and low noise / clean earth systems incorporated. As well as dual tap-offs, both standard and low noise / clean earth tap-offs can be plugged into any socket outlet along the busbar length. The dual tap-off incorporates both standard and low noise cables Optimum layout flexibility is achieved by positioning busbar lengths a maximum of 5·2 m apart and 2·5 m from the wall, and by connecting the 3 m tap-off units to floor outlet boxes. This means every part of the floor area can be served. Flexible interlinks can be used to overcome obstructions or used as corners if required
Integral connector
50 mm
185 mm
7 mm Ø
7 mm Ø
99 mm
Cat. No. DZ1210
21 mm to underside and 36 mm to top of busbar length
Cat. No. DZ1230
n Dimensions
75
93
250 46
46 2 x 25 Ø
109
68
118
47
32
15
25 Ø
65
End view A
End view B
92
Integral fixing bracket fixing centres
2·5 m
Example floor layout
feed unit
5·2 m
5·2 m
5·2 m
socket outlet points every 300 or 600 mm along busbar run
All dimensions (mm) are nominal
18
3 m flexible tap-off unit
floor service outlet box
integral connectors
n Product configuration Tap-off connection
Flexible interlink Flexible interlink boxes must be securely fixed inline to surface so no movement can take place after fixing
Depress tap-off side clips and push down Tap-off
Side clip Push down
Interlink feed entry socket. Remove dust cover label
Make sure both tapoff side clips are fully pushed home on both sides of tthe bar
Remove dust cover from end entry socket before use
Screw fix to surface
Feed unit (Cat. No. DF1010) Sub-cabling
Tap-off connection Tap-off metal flexible conduit
Feed unit protective earth terminal and earth bond Protective earth must always be connected via the earth terminal block
Lift lid
20 mm Ø conduit fitting. Tighten back nut securely
Connector terminals
Lift terminal tab to access terminal screws and close after use
25 mm Ø cable conduit fixing hole Close lid and secure with lid fixing screw before power up
Feed unit (Cat. No. JF2010 and JF2010R) Sub-cabling
Tap-off connection Tap-off metal flexible conduit
Feed unit protective earth terminal and earth bond Protective earth must always be connected via the earth terminal block
Lift lid
Connector terminals
20 mm Ø conduit fitting Tighten back nut securely
Lift terminal tab to access terminal screws and close after use Clean earth 25 mm Ø cable conduit fixing hole Close lid and secure with lid fixing screw before power up
All dimensions (mm) are nominal
19
Electrak® powertrack / underfloor busbar system design and installation (continued) n Product configuration (continued) Feed unit (Cat. No. KF3010) Sub-cabling
Dual tap-off connection (dark green) Tap-off metal flexible conduit
Lift terminal tab to access terminal screws and close after use
Protective earth must always be connected via the earth terminal block
Feed unit protective earth terminal and earth bond
Lift lid
20 mm Ø conduit fitting Tighten back nut securely
Connections L1, N1, CE = low noise L2, N2, PE = standard
Connections L1, N1, CE = low noise L2, N2, PE = standard Connector terminals Clean earth 2 x 25 mm Ø cable conduit fixing hole
Close lid and secure with lid fixing screw before power up
3 phase tap-off connection
Feed unit (Cat. No. NF4010) Sub-cabling
Tap-off metal flexible conduit Feed unit protective earth terminal and earth bond Protective earth must always be connected via the earth terminal block
Lift lid
20 mm Ø conduit fitting Tighten back nut securely
Connector terminals
Lift terminal tab to access terminal screws and close after use
25 mm Ø cable conduit fixing hole Close lid and secure with lid fixing screw before power up
Tap-off connection
Feed unit (Cat. No. YF5010 and YF5010R) Sub-cabling
Tap-off metal flexible conduit Feed unit protective earth terminal and earth bond Protective earth must always be connected via the earth terminal block
Lift lid
Connector terminals
Lift terminal tab to access terminal screws and close after use
25 mm Ø cable conduit fixing hole Close lid and secure with lid fixing screw before power up
All dimensions (mm) are nominal
20
20 mm Ø conduit fitting Tighten back nut securely
Electrak® powertrack / underfloor busbar system installation (continued)
All integral fixing brackets must be fixed to surface at 1·2 m fixing centres from first bracket on each busbar length
1 Fix feed unit to surface Feed unit
Make chalk line to align busbar lengths
Direction of busbar run
2 Connect busbar length to feed unit Integral connector Busbar length
Remove dust cover Push down
Make sure connector clips are fully pushed home on both sides
Push down
Additional length
Feed unit
3 Connect additional busbar lengths
Remove dust cover before connecting additional lengths
First fixing bracket Pull out fixing bracket lugs and screw fix on both sides
4 Secure busbar lengths to surface Tap-off outlets reusable plastic dust covers 600 mm
600 mm between fixing bracket
MS screws supplied
Integral track fixing bracket
First integral track fixing bracket
Busbar length
Integral connector Feed unit Busbar length
21 mm
All dimensions (mm) are nominal
Track feeds are screw fixed to bottom half of fixing bracket Cat. No. DZ1210
First track integral fixing brackets must be screw fixed to Cat. No. DZ1230 fixing bracket
Cat. No. DZ1230 fixing bracket
Cat. No. DZ1210 fixing bracket fixed at 600 mm centres along busbar length Bracket fixing dimensions to surface 50 mm
185 mm 50 mm Ø
99 mm
fixing brackets
99 mm
5 Raised-off floor
Track run
21
Electrak® powertrack / underfloor busbar system technical data n Earth fault loop impedance
n Standards
Approved to ASTA Standard 138 BS EN 61534-22 : 2014 and IEC 61534-22 : 2014 Manufactured within an approved ISO 9001 : 2015 and ISO 14001 : 2015 facility Assessed Quality Assurance Certificate No. 2029 Electrak powertrack / underfloor busbar fully complies with the requirements of BS 7671 : 2018
BS 7671 : 2018 requires accurate determination of the total earth loop impedance, which must be sufficiently low to allow the protective device to operate within the specified time, which for socket outlets is 0·4 seconds. The values relevant to Electrak powertrack / underfloor busbar for calculating the earth fault loop impedance are shown in the electrical test data table, see opposite
n Durability Electrak systems are superbly designed and extremely robust. They can be expected to stand up to all normal site conditions. Electrak powertrack / underfloor busbar has been short circuit strength tested by ASTA
n Installations with high protective conductor currents
7.1
Resistance to impact
Medium impact – 5J
7.2.2
Connection
Tap-off is intended to be connected/disconnected when the system is energised but without a load connected
7.3
Degree of protection
IP40
7.4
Degree of pollution
Pollution degree 2
All unfused tap-offs comply with Regulation 543·7 without the need for additional earth conductors. Regulation 543·7·1·203 (ii) states “a single copper protective conductor having a cross-sectional area of not less than 4 mm2, complying with the requirements of Regulations 543·2 and 543·3, the protective conductor being enclosed to provide additional protection against mechanical damage, for example, within a flexible conduit” For installations with high protective conductor currents requiring fused tap-offs, a 543·7 compliant tap-off must be used. Normally fused tap-offs incorporate 1·5 mm2 conductors, however in our fused 543·7 tap-offs, the 1·5 mm2 earth conductor is replaced with a 4 mm2 conductor and are therefore compliant with Section 543·7·1·203 (ii)
7.5
Rated impulse withstand voltage
Category III - 4kV
n 32 A tap-off unit
7.101
Type of floor treatment
Dry treatment of floor
7.102
Intended location
Underfloor powertrack system
n Classifications according to BS 61534-22 : 2014
n Ambient temperature rating factors The current carrying capacity for a powertrack / underfloor busbar (In) is affected by the ambient temperature For Electrak powertrack / underfloor busbar the ambient rating factor Ka is equal to 1 for ambient temperatures up to and including 35° C Iz = Ka In Where : Iz = e ffective current carrying capacity for continuous service under particular installation conditions Ka = ambient temperature factor In = nominal current carrying capacity For ambient temperatures exceeding 35° C the values of Ka and Iz are given in the following tables
The 3 m 32 A tap-off unit comprises an unfused tap-off with 2·6 m of flexible metal conduit with integral 4 mm2 LSOH conductors These units are designed to comply with Regulation 543·7·1·203 (ii) of the IET Wiring Regulations by virtue of the following : • maximum length of cable is 3 m • it is factory assembled and fully tested item with cable installed in high quality flexible conduit Fault condition protection for the tap-off assembly and the floor box socket outlets is delivered by the circuit protection device Disconnection time for socket outlets is 0·4 seconds (Regulation 411·3·2·2). The Electrak system meets this requirement Tap-off units in excess of 3 m should only be used if they contain a fuse or the busbar run is protected by a protective device not exceeding 32 A
Powertrack / underfloor busbar system Ambient 20°C 25°C 30°C 35°C 40°C 45°C 50°C Ka 1 0·95 0·85 0·80 Iz 63 A 59 A 53 A 50 A 32 A unfused tap-off (using thermosetting 90°C cables) Ambient 20°C 25°C 30°C 35°C 40°C 45°C 50°C Ka 1 0·95 0·85 0·80 Iz 32 A 30 A 27 A 25 A 13 A fused tap-off (using 2·5 mm2 thermosetting 90°C cables) Ambient 20°C 25°C 30°C 35°C 40°C 45°C 50°C Ka 1 Iz 13 A References : BS 7671 : 2018
All dimensions (mm) are nominal
22
Earth fault loop impedance
Volt drops (live and neutral) Busbars
Cable connector Integral connector 32 A tap-off + 4 mm2 cable Flexible corner assembly + 10 mm2 cable
3·0 mV/A/m 0·4 mV/A 0·4 mV/A 0·4 mV/A 11 mV/A/m 1·5 mV/A 4·0 mV/A/m
Mechanical data
E24 – E28 E28R Number of conductors 3-6 3 Busbar conductor cross sectional area 13 mm2 13 mm2 Housing cross sectional area (copper equivalent) 13 mm2 13 mm2 2 Cable terminal capacity 16 mm 16 mm2 Tap-off cable 32 A 4 mm2 4 mm2 Tap-off cable 13 A fused 1·5 mm2 2·5 mm2 Tap-off conduit, up to 4 conductors 16 mmØ 20 mmØ Tap-off conduit, 5 and 6 conductors 20 mm2 N/A Flexible corner cable (tri-rated, high temperature) 10 mm2 10 mm2 Flexible corner conduit 25 mmØ 25 mmØ IP rating 40 40
Phase busbar Earth busbar Earth housing Earth busbar and housing Cable connector Integral connector 32 A tap-off + 4 mm2 cable Flexible corner assembly + 10 mm2 cable Rated conditional short-circuit current Ambient temperature
1·5 mΩ/m 1·5 mΩ/m 1·1 mΩ/m 0·8 mΩ/m 0·4 mΩ 0·6 mΩ 0·6 mΩ 11 mΩ/m 1·5 mΩ 4·0 mΩ/m 16 KA 25˚C
Electrical test data Rated current
Rated voltage Frequency Conductor resistance - live and neutral Conductor impedance
63 A 230/400 V~ 50 Hz 3·0 mΩ/m 1·5 mΩ/m
Material specifications
Housing - busbar lengths Busbars Busbar insulator
Galvanised steel, natural finish High conductivity copper (Tinned version is electro-tin plated) PTFE
Flame retardant polycarbonate Acetal Flame retardant polycarbonate Copper (Tinned version is plated) Copper (Tinned version is plated) Electro-galvanised steel LSOH to BS EN 50525 Tri-rated to BS 6231 Galvanised steel Brass (Tinned version is plated) Galvanised steel To BS 1362, ASTA approved
Integral connectors / Tap-off outlets Tap-off outlet entry shutter Tap-off housing Integral connector blades Tap-off blades Tap-off/flexible corner conduit, metal Tap-off cable Flexible interlink cable Feed box/flexible interlink boxes Feed connector terminals/earth block Fixing brackets 13 A tap-off, fuse
All dimensions (mm) are nominal
23
FLOOR BOXES choice, flexibility &
easy installation
Raised access floor boxes and slab boxes offer complete versatility. Floor boxes are available pre-wired with powertrack tap-off, or supplied empty (unassembled), with a choice of single or separate compartment bases and three depth options. With a vast selection of power and data plates available, boxes can be tailored to the specific requirements of each office installation. 24
NOTE : Please consult us for different plate options on +44 (0) 370 608 9020. Photos are only illustrative.
Available in 2, 3 and 4 compartments and with a choice of three depths, Electrak floor boxes have been developed with a host of special features:
n
n
n
n
vailable pre-wired with tap-off or supplied A unassembled A wide selection of power and data plates, including RCD options ingle or separate compartment bases for ease of S data cabling Rapid installation and fast ratchet mechanism which adjusts to floor finish thickness
2
1
3
4
6
5
7
Rapid fit /remove mechanism adjusts for flooring thickness Quick-fit, reversible lid for rapid installation Durable ABS trim and lid surround Various RCD protection options available
8
Rapid fit push lock secures base in floor aperture Available pre-wired with tap-off Three depth options: 75mm, 85mm, 110mm Single or separate compartment bases NOTE : Please consult us for different plate options on +44 (0) 370 608 9020. Photos are only illustrative.
25
access floor service outlet and slab mounted floor boxes empty boxes and accessory plates
2 compartment
mm
366
mm
mm
mm
290
4 compartment
230
230
mm 230
To configure boxes as required, select : 1. Box depth 2. Number of compartments required 3. Desired accessory plates
3 compartment
366
mm
100 mm width plates
100 mm width plates
75 mm width plates
Single base – 75 mm depth
CR2001
CR011
CR4001
Single base – 85 mm depth (standard box)
CR2002
CR012
CR4002
Single base – 110 mm depth
CR2003
CR013
CR4003
Separate compartment base – 75 mm depth
CR2004
CR014
CR4004
Separate compartment base – 85 mm depth
CR2005
CR015
CR4005
Separate compartment base – 110 mm depth
CR2006
CR016
CR4006
Empty boxes
Slab boxes
Fix directly onto floor slab (supplied empty)
26
Example
1 compartment
2 compartment
3 compartment
4 compartment
CR5102
CR5202
CR5302
CR5402
2 compartment
Accessory plates
mm
366
mm
mm
mm
290
4 compartment
230
230
mm 230
To configure boxes as required, select : 1. Box depth 2. Number of compartments required 3. Desired accessory plates
3 compartment
366
mm
For 1, 2 and 3 compartment boxes
For 4 compartment boxes
Blank plate
CR020
CR4100
2 gang switched socket outlet
CR022
CR4101
2 gang switched socket outlet, low noise / clean earth
CR023
CR4102
2 gang non-standard switched socket outlet
CR027
CR4103
2 gang unswitched socket outlet
CR029
CR4104
3 gang unswitched socket outlet
CR030
CR4195
3 gang unswitched socket outlet, low noise / clean earth
CR044
CR4118
2 gang RCD socket outlet
CR036
CR4111
2 gang RCD socket outlet, low noise / clean earth
CR043
CR4117
2 gang RCD shallow socket outlet specifically for 75 mm deep floor boxes
CR046
CR4121
2 gang RCD shallow socket outlet low noise / clean earth specifically for 75 mm deep floor boxes
CR053
CR4127
Punched plate for 2 x 1 gang accessories (60·3 mm fixing centres)
CR026
–
Punched plate for 2 gang accessories (120·6 mm fixing centres)
CR028
–
Angled punched plate for 4 x RJ45 sockets (37 mm x 22 mm cut-outs)
CR042
CR4115
2 x LJ2 accessory plate (50 mm fixing centres)
CR031
CR4106
4 x BNC connector plate
CR033
CR4108
4 x Data / telecoms plate (37 mm x 22 mm cut-outs)
CR024
CR4112
6 x Data / telecoms plate (37 mm x 22 mm cut-outs)
CR025
CR4113
Punched plate for 2 x 50 mm x 50 mm Euro Module
CR035
–
Punched plate for 3 x 45 mm x 45 mm Arteor modules
CR070
CR4200
27
access floor pre-wired service outlet boxes and accessory plates Pre-wired service outlet boxes with Electrak tap-offs 1. S elect powertrack tap-off and desired configuration 2. S elect additional accessory plates (if required) Includes 1 x twin switched socket outlet
Includes 2 x twin switched socket outlet
Includes 1 x 2 gang RCD socket outlet
Includes 2 x 2 gang RCD socket outlet
DP1332 - 3 m
CR100
CR102
CR100R
CR102R
DP1532 - 5 m
CR101
CR103
CR101R
CR103R
JP2332 - 3 m
CR110
CR112
CR110R
CR112R
JP2532 - 5 m
CR111
CR113
CR111R
CR113R
YP5332 - 3 m
CR104
CR106
CR104R
CR106R
YP5532 - 5 m
CR105
CR107
CR105R
CR107R
3 compartment
Electrak 24 - standard tap-off
Electrak 25 - low noise / clean earth tap-off
230 mm 366
mm
Electrak 28 - auxiliary earth tap-off
Additional plates for 3 compartment boxes
Blank plate
CR020
2 x LJ2 accessory plate (50 mm fixing centres)
CR031
Punched plate for 2 x 1 gang accessories (60¡3 mm fixing centres)
CR026
4 x BNC connector plate
CR033
Punched plate for 2 gang accessories (120¡6 mm fixing centres)
CR028
4 x Data / telecoms plate (37 mm x 22 mm cut-outs)
CR024
Angled punched plate for 4 x RJ45 sockets (37 mm x 22 mm cut-outs)
CR042
6 x Data / telecoms plate (37 mm x 22 mm cut-outs)
CR025
100 mm plate for 2 x 50 mm x 50 mm Euro Module
100 mm plate for 3 x 45 mm x 45 mm Arteor modules
Please advise illustrations
CR035
CR070
NOTE : P lease consult us for different plate options on +44 (0) 370 608 9020. Product drawings are only illustrative.
28
Includes 1 x twin switched socket outlet
Includes 2 x twin switched socket outlet
Includes 1 x 2 gang RCD socket outlet
Includes 2 x 2 gang RCD socket outlet
Modular RCD protecting 2 x twin switched socket outlets and 1 spare compartment
DP1332 - 3 m
CR120
CR122
CR120R
CR122R
CR4402
DP1532 - 5 m
CR121
CR123
CR121R
CR123R
CR4403
JP2332 - 3 m
CR130
CR132
CR130R
CR132R
CR4412
JP2532 - 5 m
CR131
CR133
CR131R
CR133R
CR4413
YP5332 - 3 m
CR124
CR126
CR124R
CR126R
CR4406
YP5532 - 5 m
CR125
CR127
CR125R
CR127R
CR4407
4 compartment
Electrak 24 - standard tap-off
Electrak 25 - low noise / clean earth tap-off
230 mm 366
mm
Electrak 28 - auxiliary earth tap-off
Additional plates for 4 compartment boxes
Blank plate
CR4100
4 x BNC connector plate
CR4108
Angled punched plate for 4 x RJ45 sockets (37 mm x 22 mm cut-outs)
CR4115
4 x Data / telecoms plate (37 mm x 22 mm cut-outs)
CR4112
2 x LJ2 accessory plate (50 mm fixing centres)
CR4106
6 x Data / telecoms plate (37 mm x 22 mm cut-outs)
CR4113
100 mm plate for 2 x 50 mm x 50 mm Euro Module
CR4110
100 mm plate for 3 x 45 mm x 45 mm Arteor modules
CR4200
NOTE : P lease consult us for different plate options on +44 (0) 370 608 9020. Product drawings are only illustrative.
29
access floor service outlet boxes
slab and screed mounted floor boxes
empty boxes
empty boxes
CR5302
CR4002 3 compartment slab floor box shown with two twin switched socket outlets, punched data plate and a powertrack tap-off CR5312
Includes grey ABS lid and trim
CR012
Selection charts p. 26 Dimensions and technical information p. 33 id and trim mouldings are precision engineered from hard wearing L durable ABS. Lid is reinforced with a galvanised mild steel plate Mounting frame and box base - 0¡9 mm thick galvanised steel Each compartment has 2 entries for 20 mm and 2 entries for 25 mm flexible conduits Grey mouldings. Alternative colours available to special order Grey plates 2, 3 and 4 compartment boxes are also available with separate individual compartment base units for convenient offsite pre-wiring Supplied in parts or fully assembled and configured to customer specification Conform to BS EN 61534-22
Pack
Cat. Nos.
2 compartment floor boxes
Empty boxes
1 1 1 1 1 1
100 mm compartment widths
CR2001 Single base - 75 mm depth CR2002 Single base - 85 mm depth (standard box) CR2003 Single base - 110 mm depth CR2004 Separate compartment base - 75 mm depth CR2005 Separate compartment base - 85 mm depth CR2006 Separate compartment base - 110 mm depth
3 compartment floor boxes
Empty boxes
100 mm compartment widths
1 1 1 1 1 1
CR011 Single base - 75 mm depth CR012 Single base - 85 mm depth (standard box) CR013 Single base - 110 mm depth CR014 Separate compartment base - 75 mm depth CR015 Separate compartment base - 85 mm depth CR016 Separate compartment base - 110 mm depth
Selection charts p. 26 Dimensions and technical information p. 33 Electrak slab floor boxes are an ideal solution for underfloor power and data requirements Used in conjunction with Electrak floor grommets, slab boxes prevent unwanted access to power and data connections
Pack
Empty boxes
75 mm compartment widths
NOTE: due to plug entry requirements, 4 x twin socket outlets will not fit into a 4 compartment floor box 1 CR4001 Single base - 75 mm depth
30
1 1 1 1 1
CR4002 Single base - 85 mm depth (standard box) CR4003 Single base - 110 mm depth CR4004 Separate compartment base - 75 mm depth CR4005 Separate compartment base - 85 mm depth CR4006 Separate compartment base - 110 mm depth
Slab floor boxes
Fixes directly onto floor slab Fast and efficient installation with integrated fixing plates Wide range of power and data accessory plates Manufactured from 0¡9 mm thick galvanised steel Each compartment has 2 entries for 20 mm and 2 entries for 25 mm flexible conduits 100 mm compartment widths Use plates from the 1, 2 and 3 compartment floor box section p. 26-27 1 CR5102 1 compartment slab floor box 1 CR5202 2 compartment slab floor box 1 CR5302 3 compartment slab floor box 75 mm compartment widths Use plates from the 4 compartment floor box section p. 26-27
1
CR5402 4 compartment slab floor box
4 compartment floor boxes
Cat. Nos.
Screed floor boxes
25 mm conduit fed, to suit screed 75 mm to 90 mm deep 1 CR5312 3 compartment screed floor box 1 CR5412 4 compartment screed floor box
NOTE : P lease consult us for different plate options on +44 (0) 370 608 9020. Photos are only illustrative.
Edge trim boxes, and metal or lockable lids are available to order contact us on +44 (0) 370 608 9020
access floor service outlet boxes accessory plates and ancillary items
Selection charts p. 26-29 Dimensions and technical information p. 33 Lid and trim mouldings are precision engineered from hard wearing durable ABS. Lid is reinforced with a galvanised mild steel plate Mounting frame and box base - 0·9 mm thick galvanised steel Each compartment has 2 entries for 20 mm and 2 entries for 25 mm flexible conduits Grey mouldings. Alternative colours available to special order. Grey plates 2, 3 and 4 compartment boxes are also available with separate individual compartment base units for convenient offsite pre-wiring Supplied in parts or fully assembled and configured to customer specification Conform to BS EN 61534-22
Pack
Cat. Nos. 1,
2 and 3 compartment accessory plates
100 mm width
1 CR020 Blank plate 1 CR022 2 gang switched socket outlet 1 CR023 2 gang switched socket outlet, low noise / clean earth 1 CR027 2 gang non-standard switched socket outlet 1 CR029 2 gang unswitched socket outlet 1 CR030 3 gang unswitched socket outlet 1 CR044 3 gang unswitched socket outlet, low noise / clean earth 1 CR036 2 gang RCD socket outlet 1 CR043 2 gang RCD socket outlet, low noise / clean earth 1 CR046 100 mm plate – 2 gang RCD switched shallow socket outlet specifically for 75 mm deep floor boxes 1 CR053 100 mm plate – low noise 2 gang RCD switched shallow socket outlet specifically for 75 mm deep floor boxes 1 CR026 Punched plate for 2 x 1 gang accessories (60·3 mm fixing centres) 1 CR028 Punched plate for 2 gang accessories (120·6 mm fixing centres) 1 CR042 Angled punched plate for 4 x RJ45 (37 mm x 22 mm cut-outs) 1 CR031 2 x LJ2 accessory plate (50 mm fixing centres) 1 CR033 4 x BNC connector plate 1 CR024 4 x Data / telecoms plate (37 mm x 22 mm cut-outs) 1 CR025 6 x Data / telecoms plate (37 mm x 22 mm cut-outs) 1 CR035 100 mm plate for 2 x 50 mm x 50 mm Euro Module 1 CR070 100 mm plate for 3 x 45 mm x 45 mm Arteor modules
Pack
Cat. Nos.
4 compartment accessory plates 75 mm compartment widths
1 CR4100 Blank plate 1 CR4101 2 gang switched socket outlet 1 CR4102 2 gang switched socket outlet, low noise / clean earth 1 CR4103 2 gang non-standard switched socket outlet 1 CR4104 2 gang unswitched socket outlet 1 CR4105 3 gang unswitched socket outlet 1 CR4118 3 gang unswitched socket outlet, low noise / clean earth 1 CR4111 2 gang RCD socket outlet 1 CR4117 2 gang RCD socket outlet, low noise / clean earth 1 CR4121 75 mm plate – 2 gang RCD switched shallow socket outlet specifically for 75 mm deep floor boxes 1 CR4127 75 mm plate – low noise 2 gang RCD switched shallow socket outlet specifically for 75 mm deep floor boxes 1 CR4115 Angled punched plate for 4 x RJ45 (37 mm x 22 mm cut-outs) 1 CR4106 2 x LJ2 accessory plate (50 mm fixing centres) 1 CR4108 4 x BNC connector plate 1 CR4112 4 x Data / telecoms plate (37 mm x 22 mm cut-outs) 1 CR4113 6 x Data / telecoms plate (37 mm x 22 mm cut-outs) 1 CR4110 75 mm plate for 2 x 50 mm x 50 mm Euromod 1 CR4200 75 mm plate for 3 x 45 mm x 45 mm Arteor modules
1 1 10 10 50 1 1 1 1 1 1
1
10 1
Ancillary items for service outlet boxes
CR0001 Floor tile cut-out template – 2 compartment CR0003 Floor tile cut-out template – 3 / 4 compartment CR0000 Cable outlet flap CR0010 Cable routers CR0011 Screws for accessory plates CR0012 Pack of 5 keys for use with lockable floor boxes CR0021 Plastic lid and trim for 2 compartment floor box CR0022 Plastic lid and trim for 3 / 4 compartment floor box CR0023 Lockable lid assembly for 2 compartment floor box CR0024 Lockable lid assembly for 3 / 4 compartment floor box CR0005 Mounting frame for vinyl floor. For 2 compartment box Replaces mounting frame attached to base CR0006 Mounting frame for vinyl floor. For 3 / 4 compartment box. Replaces mounting frame attached to base CR0007 Floor box lid handle CR0020 Metal lid and trim - replacement for 3 and 4 compartment boxes - powder coated grey
Electrak tap-offs p. 10-14, 16-17 31
access floor pre-wired service outlet boxes 3 and 4 compartment
CR100
CR122
Selection chart p. 28-29 Dimensions and technical information p. 33 Electrak floor boxes can be supplied pre-wired to powertrack tap-offs with any variation of sockets, tap-offs, depth or other configuration
Pack
Cat. Nos.
3 compartment pre-wired boxes with 1 x TSSO
100 mm compartment widths
Single base – 85 mm depth, pre-wired with : 1 CR100 3 m Electrak 24 standard tap-off Cat. No. DP1332 1 CR101 5 m Electrak 24 standard tap-off Cat. No. DP1532 1 CR110 3 m Electrak 25 low noise / clean earth tap-off Cat. No. JP2332 1 CR111 5 m Electrak 25 low noise / clean earth tap-off Cat. No. JP2532 1 CR104 3 m Electrak 28 auxiliary earth tap-off Cat. No. YP5332 1 CR105 5 m Electrak 28 auxiliary earth tap-off Cat. No. YP5532
Pack
Cat. Nos.
100 mm compartment widths
Single base – 85 mm depth, pre-wired with : 1 CR102 3 m Electrak 24 standard tap-off Cat. No. DP1332 1 CR103 5 m Electrak 24 standard tap-off Cat. No. DP1532 1 CR112 3 m Electrak 25 low noise / clean earth tap-off Cat. No. JP2332 1 CR113 5 m Electrak 25 low noise / clean earth tap-off Cat. No. JP2532 1 CR106 3 m Electrak 28 auxiliary earth tap-off Cat. No. YP5332 1 CR107 5 m Electrak 28 auxiliary earth tap-off Cat. No. YP5532
Also available : - pre-wired boxes with fused tap-offs - shallow or deep versions - separate compartment bases contact us on +44 (0) 370 608 9020
32
75 mm compartment widths
Single base – 85 mm depth, pre-wired with : 1 CR120 3 m Electrak 24 standard tap-off Cat. No. DP1332 1 CR121 5 m Electrak 24 standard tap-off Cat. No. DP1532 1 CR130 3 m Electrak 25 low noise / clean earth tap-off Cat. No. JP2332 1 CR131 5 m Electrak 25 low noise / clean earth tap-off Cat. No. JP2532 1 CR124 3 m Electrak 28 auxiliary earth tap-off Cat. No. YP5332 1 CR125 5 m Electrak 28 auxiliary earth tap-off Cat. No. YP5532
4 compartment pre-wired boxes with 2 x TSSO
3 compartment pre-wired boxes with 2 x TSSO
4 compartment pre-wired boxes with 1 x TSSO
75 mm compartment widths
Single base – 85 mm depth, pre-wired with : 1 CR122 3 m Electrak 24 standard tap-off Cat. No. DP1332 1 CR123 5 m Electrak 24 standard tap-off Cat. No. DP1532 1 CR132 3 m Electrak 25 low noise / clean earth tap-off Cat. No. JP2332 1 CR133 5 m Electrak 25 low noise / clean earth tap-off Cat. No. JP2532 1 CR126 3 m Electrak 28 auxiliary earth tap-off Cat. No. YP5332 1 CR127 5 m Electrak 28 auxiliary earth tap-off Cat. No. YP5532 Pre-wired floor boxes can be supplied with RCD rather than standard sockets. Add an R to the end of the part numbers for an RCD version. For example CR100R is a 3 compartment floor box with a twin RCD socket and a DP1332 tap-off
NOTE : P lease consult us for different plate options on +44 (0) 370 608 9020. Photos are only illustrative.
access floor service outlet boxes
access floor service outlet boxes
with RCD protection
technical information n Floor boxes Dimensions Lid can accommodate carpets up to 6 mm depth Accessory plates are 172 mm long, with 162 mm fixing centres Materials Lid and trim mouldings are precision engineered from hard wearing durable ABS. Lid is reinforced with a galvanised mild steel plate Mounting frame and box base – 0¡9 mm thick galvanised steel Floor service unit conforms to BS EN 61534-22 Wiring Each compartment has 2 entries for 20 mm and 2 entries for 25 mm flexible conduits Colour Grey mouldings. Alternative colours available to special order Grey plates
CR4401
Selection charts p. 26-29 Dimensions and technical information (opposite)
Dimensions from top of floor tile into floor void
Electrak floor boxes are available with various RCD protection options and can be supplied pre-wired to powertrack tap-offs
Pack
C A
Cat. Nos. Floor
boxes with RCD protection and 2 x TSSO
B
Boxes contain 1 spare 75 mm width compartment
1 1
CR4400 Includes standard sockets CR4401 Includes low noise sockets
Pre-wired RCD protected floor boxes
Boxes contain RCD and 2 x TSSO with 1 spare 75 mm compartment 1 1 1 1
CR4402 CR4403 CR4412 CR4413
Pre-wired Pre-wired Pre-wired Pre-wired
with with with with
Cat. Cat. Cat. Cat.
No. No. No. No.
DP1332 tap-off DP1532 tap-off JP2332 tap-off JP2532 tap-off
303
35 45 45
35 35 60
Compartment
W L (mm) (mm)
350 245 350 245
3C 4C
n To install access floor box
15 max adjustment to bring level with finished floor Screed
25 Trunking 15 ribbon screed Structural floor slab
15 max adjustment to bring level with finished floor 75
75 85 110
Screed floor boxes
221
60
A B C Accessory Underside lid to top box depth of accessory (mm) (mm) (plug clearance) (mm)
Screed
38 Trunking 15 ribbon screed Structural floor slab
L
W
15 max adjustment to bring level with finished floor
Cut hole in raised floor tile, lower completeScreed box into 25 Trunking aperture and push firmly 15 ribbon screed down Structural floor slab
60
15 max adjustment to bring level with finished floor 75
Screed
38 Trunking 15 ribbon screed Structural floor slab
Floor tile cut-out dimensions 2 compartment : 263 mm x 203 mm1 3 and 4 compartment : 340 mm x 203 mm1 Floor cut-out aperture is the same for single base or separate compartment base To fit carpet : Detach lid and trim assembly by lifting the blue locking handles and lifting out. Cut and fit carpet. Push lid and trim assembly back into place
NOTE : P lease consult us for different plate options on +44 (0) 370 608 9020. Photos are only illustrative.
1 : The aperture dimension 203 mm has a fixing tolerance between 203 to 205 mm
33
FLOOR GROMMETS perfectly balancing
capacity & size ACCESS GROMMETS The Electrak range of simple-to-install access grommets allow cables and conduit to link between underfloor power and desk power systems. n n
n
34
Ranging from 144mm to 232mm in diameter 69mm diameter grommet can accommodate up to 3 x 1 32mm conduits - perfectly balancing capacity and size Push-fit lid with optional screw fixing to prevent unauthorised access
POWER AND DATA GROMMETS
n
n
The Electrak range of cleaner’s grommets are the latest addition to its power and data grommets range. Within their 169mm diameter, the grommet can house a flat RCD socket and provide ample space for the user to plug in or unplug equipment.
n
n
leaner’s grommet with flat C mounted RCD socket or standard socket options Push-fit lid with cable flap feature pring loaded screws for rapid S installation vailable pre-wired to powertrack A tap-off
1 1
2
3
4
5 6
Removable inlay for optional carpet fitting Cable flap allows permanent connection of services Flat mounted RCD socket
169mm diameter provides the perfect balance between size and capacity Spring loaded screws for rapid installation Available pre-wired to powertrack tap-offs 35
floor grommets access / power and data
EG0030
EG0010
EG0040
EG0045
Dimensions and technical information p. 37
Pack
Cat. Nos.
Plastic access grommets
Pack
Cat. Nos.
Plastic power and data grommets
Quick fit installation 169 mm Ø – cut-out size 152 mm Ø Precision engineered from hard wearing durable ABS Quick fit installation Grey mouldings. Other colours available to special Precision engineered from hard wearing durable ABS order Grey mouldings. Other colours available to special Conform to BS EN 61534-22 order. Conform to BS EN 61534-22 Simply secured by pushing down the spring-loaded Removable carpet recess screws and rotating a quarter turn Cable flap feature so grommet lid can be closed Recommended for use in light traffic areas while in use Avoid positioning in walkways or under static loads Simply secured by pushing down the spring-loaded screws and rotating a quarter turn 1 EG0010 144 mm Ø – cut-out size 127 mm Ø Recommended for use in light traffic areas Can accomodate all cable types or three metal Avoid positioning in walkways or under static loads conduits up to a 20 mm Ø or 25 mm without foam 1 EG0040 13 A power grommet 1 EG0030 169 mm Ø – cut-out size 152 mm Ø Supplied complete with 13 A unswitched socket Allows power, data and flexible conduit up to 32 mm to pass through raised access floor 1 EG0045 RCD power grommet Lid can be locked with screw (included) Supplied complete with 13 A RCD socket Maximum number of conduits : 1 EG0051 13 A power/data grommet 9 x 20 mm Ø Supplied complete with 13 A socket and 5 x 25 mm Ø 1 x 37 x 22 mm cut-out 3 x 32 mm Ø 1 EG0052 Data grommet 1 EG0055 232 mm Ø – cut-out size 215 mm Ø Supplied complete with data plate 2 x 37 x 22 mm cut-out High capacity grommet Recommended for installation in light traffic areas Cleaners floor grommets 169 mm Ø
Aluminium access grommet
Body – cast aluminium Lid – injection moulded plastic Nylon 66 with neoprene cable gasket Secured by quarter-turn fasteners Floor depth 25 to 55 mm Access grommet depth 60 mm (95 mm when back box included) 1 EG0015 144 mm Ø – cut-out size 127 mm Ø Allows power, data and flexible conduit up to 25 mm to pass through raised access floor
Aluminium power grommet
1 EG0025 13 A power grommet Supplied complete with 13 A switched socket
36
1 1
EG0053 Non-standard 5 A socket EG0035 Single switched socket
Pre-wired power grommets Recommended for use in light traffic areas 169 mm Ø – cut-out size 152 mm Ø Cleaners socket version 1 EG0041 DP1332 - 3 m unfused 1 EG0042 DP1532 - 5 m unfused 1 EG0043 DP1313 - 3 m 13 A fused 1 EG0044 DP1513 - 5 m 13 A fused RCD socket version 1 EG0046 DP1332 - 3 m unfused 1 EG0047 DP1532 - 5 m unfused 1 EG0048 DP1313 - 3 m 13 A fused 1 EG0049 DP1513 - 5 m 13 A fused
floor grommets technical information
144 mm Ø
n 144 mm Ø plastic floor grommet
55 mm
n To install plastic floor grommets
Dimensions Cat. No. EG0010
A
B
Lift handle and pull to remove lid
Push grommet into raised floor tile aperture Push down spring loaded screws and rotate quarter turn to secure Ensure wings are located under floor panel For honeycombed floor panels one wing should face downwards and one wing should face upwards
C
D
E
Slide lid into lug holes
(1) Push down lid to close (2) If grommet is not in use, replace cable access insert
144 mm Ø
55 mm 90
Recommended hole cutter is a 5"/127 mm hole saw blade
125 mm min 127 mm min
Wing
Floor panel cut-out diameter
n 169 mm Ø plastic floor grommets
90 mm
Dimensions 125 mm min 127 mm min
Access grommet Cat. No. EG0030
Recommended hole cutter is a 5"/127 mm hole saw blade
55
Floor panel cut-out diameter
1
2
Ø148 Ø 169
60
Power grommet
102
Cable access insert Drop cable access insert into housing opening
Ø148
90
n 144 mm Ø aluminium grommets Access grommet
Ø 169
Recommended hole cutter is a 6’’/152 mm hole saw blade
Cat. No. EG0015 60
n 232 mm Ø plastic floor grommet
40
60 95
Dimensions Large quick fit grommet Cat. No. EG0055
90
232 mm Ø
13 A power grommet
144
58 mm
Cat. No. EG0025 40
60 95
213 mm min 215 mm max
Floor panel cut-out diameter Recommended hole cutter is a adjustable hole saw blade with Ø range of 40 mm - 300 mm
144
Recommended hole cutter is a 5’’/127 mm hole saw blade
All dimensions (mm) are nominal
37
INTERSOC-R
TM
fast, reliable, adaptable
modular desk power
38
COMPLETE SOLUTIONS FOR DEMANDING ENVIRONMENTS Intersoc-R is a modular desk power system designed to meet the demands of modern workplaces for faster and more adaptable solutions. Designed with speed of installation and flexibility in mind, Intersoc-R’s modular configuration enables thousands of different combinations to be made providing solutions for every installation requirement.
n
n
n
n
Modular system - rapid configuration and easy workstation relocation ush-fit connection - modules P can simply be disconnected and additional modules inserted usbar interconnection B no need for wiring Easily adapted to meet the changing demands of the workplace
39
The next
GENERATION
of power distribution
Available in standard and clean earth versions, with fixed or rotatable socket options and a safe shuttered electrical connection, Intersoc-R is the next generation of power distribution... n
n
n
n
40
Intersoc On-desk Personal power and data system
Simple push-fit, module connection with auto-lock mechanism creates robust joints and makes installation quicker and easier 2 A system with safe shuttered electrical connections 3 for additional safety, meets the requirements of BS 7671 : 2018 (including section 543.7) CB, RCD and RCBO modules, with reversible hinged M covers, provide a full range of circuit protection options , 3 or 4 gang British standard socket modules 2 with fixed or rotatable, fused or unfused (BS 6396) sockets options - all the options you need to meet the requirements of any installation
Outgoing connections: flexible interlink or end cap with ST or GST options n
NEW
Find out more on page 48
41 41
Intersoc-RTM desk modules electrical supply
IAB301A
IAB002A IAB660B IAB312A
IAB610BB
Dimensions and technical information p. 44-47 Intersoc-R features fast modular connection with push-fit auto lock mechanism, safe shuttered electrical connections and a robustly designed rigid joint between modules. Available in standard and clean earth versions Independently approved by Intertek. Complies with BS 5733 and the relevant parts of BS 1363 part 2. Manufactured in an approved ISO 9001 : 2015 facility. Meets the requirements of BS 7671 : 2018 for high integrity earthing (section 543·7)
Pack
Cat. Nos.
1 1 1 1
32 A pre-wired feed modules Standard earth tap-offs (E24 - White tap-off)
IAB311A 3 m unfused metal tap-off Cat. No. DP1332 IAB312A 5 m unfused metal tap-off Cat. No. DP1532 IAB315A 3 m 13 A fused 543·7 metal tap-off Cat. No. DP1327 IAB316A 5 m 13 A fused 543·7 metal tap-off Cat. No. DP1527
Low noise / clean earth tap-offs (E25 - Green tap-off)
1 1 1 1
IAC311A 3 m unfused metal tap-off Cat. No. JP2332 IAC312A 5 m unfused metal tap-off Cat. No. JP2532 IAC315A 3 m 13 A fused 543·7 metal tap-off Cat. No. JP2327 IAC316A 5 m 13 A fused 543·7 metal tap-off Cat. No. JP2527
1 1 1 1
IAF311A 3 m unfused metal tap-off Cat. No. YP5332 IAF312A 5 m unfused metal tap-off Cat. No. YP5532 IAF315A 3 m 13 A fused 543·7 metal tap-off Cat. No. YP5327 IAF316A 5 m 13 A fused 543·7 metal tap-off Cat. No. YP5527
1 1
Auxiliary earth tap-offs (E28 - Red tap-off)
32 A re-wirable feed modules
IAB301A Standard earth (for flexible conduit) IAC301A Low noise (for flexible conduit)
32 A feed units with in-built Neutrik connectors
1 1
IAB301E Standard earth IAC301E Low noise
32 A tap-offs pre-wired to Neutrik connectors (NAC3 - 2FC)
1 1 1 1
42
1 1 1 1
Standard earth tap-offs (E24)
IAB311E 3 m unfused metal tap-off Cat. No. DP1332 IAB312E 5 m unfused metal tap-off Cat. No. DP1532 IAB315E 3 m 13 A fused 543·7 metal tap-off Cat. No. DP1327 IAB316E 5 m 13 A fused 543·7 metal tap-off Cat. No. DP1527 Low noise / clean earth tap-offs (E25)
IAC311E 3 m unfused metal tap-off Cat. No. JP2332 IAC312E 5 m unfused metal tap-off Cat. No. JP2532 IAC315E 3 m 13 A fused 543·7 metal tap-off Cat. No. JP2327 IAC316E 5 m 13 A fused 543·7 metal tap-off Cat. No. JP2527
Pack
1 1 1
Cat. Nos. 16
A feed modules pre-wired to 13 A fused plug
IAB002A With 2 m 1·5 mm2 cable IAB003A With 3 m 1·5 mm2 cable IAB005A With 5 m 1·5 mm2 cable
1
16 A rewirable feed modules
IAB201A Rewirable feed module (for cable)
16 A feed units with in-built GST connector
1 1
IAB660B Compact feed module with male GST connector IAB201B Feed module with male GST and earth bond lead
16 A pre-wired connection leads
13 A fused plug pre-wired to GST connector
1 1 1
IAB002B With 2 m 1·5 mm2 cable IAB003B With 3 m 1·5 mm2 cable IAB005B With 5 m 1·5 mm2 cable
1 1 1
GST to GST connection leads
IAB610BB 1 m length IAB620BB 2 m length IAB630BB 3 m length
Intersoc-RTM desk modules protection, BS sockets, end caps and interlinks
IAC502R
IAB402A
IAB533F
IAB450A
IAZ001A
IAB703A
IAB600B
IAB610B
IAB504R
Dimensions and technical information p. 44-47 The BS version is available with fixed or rotatable sockets. Individually fused sockets are available to meet the requirements of BS 6396 : 2008 + A1 2015 (5 x 20 mm anti-surge ceramic fuses) A wide range of interconnection solutions are available. When 16 A cabling interconnection is used with 32 A under desk solutions, suitable de-rating protection devices must be incorporated to protect the cables All protection and switching modules, end caps and interlinks are universally compatible with standard and clean earth / low noise systems
Pack
1 1 1 1 1 1 1 1 1 1 1 1
Cat. Nos.
1 1 1 1
1 1
1 1
1 1
1 1
1 1 1 1
3 gang individually fused
4 gang unfused
4 gang individually fused
Socket modules – low noise / clean earth (green sockets) 2 gang unfused
IAC502F Fixed sockets IAC502R Rotatable sockets
3 gang unfused
IAB534F 3·15 A – fixed sockets IAB534R 3·15 A – rotatable sockets
2 gang individually fused
IAB504F Fixed sockets IAB504R Rotatable sockets
modules – low noise / clean earth (green sockets) (continued)
1 1
1 1 1 1
2 gang individually fused
IAC532F 3·15 A – fixed sockets IAC532R 3·15 A – rotatable sockets
1 1
1
3 gang individually fused
IAC533F 3·15 A – fixed sockets IAC533R 3·15 A – rotatable sockets
3 gang unfused
IAC503F Fixed sockets IAC503R Rotatable sockets
4 gang unfused
IAC504F Fixed sockets IAC504R Rotatable sockets
2 gang unfused
IAB533F 3·15 A – fixed sockets IAB533R 3·15 A – rotatable sockets
Cat. Nos. Socket
IAB503F Fixed sockets IAB503R Rotatable sockets
Pack
IAB532F 3·15 A – fixed sockets IAB532R 3·15 A – rotatable sockets
Socket modules – standard (grey sockets)
IAB502F Fixed sockets IAB502R Rotatable sockets
Protection and switching modules
IAB401A With 13 A fuse IAB402A With 13 A fuse and sw/neon IAB403A With 13 A fuse and neon IAB404A 32 A max. single isolation module IAB405A With 30 mA RCD IAB408A With neon indicator IAB420A With 16 A MCB IAB430A With 20 A MCB IAB440A With 32 A MCB IAB450A With 16 A RCBO IAB460A With 20 A RCBO IAB470A With 32 A RCBO
4 gang individually fused
IAC534F 3·15 A – fixed sockets IAC534R 3·15 A – rotatable
End cap
IAZ001A Blank end cap
Intersoc to Intersoc pre-wired interconnection
1 1 1 1 1 1
1 1 1 1 1 1
Power out end caps 16 A
1 1
Without flex
IAB600B End cap with female GST connector IAB600C End cap with female ST connector
1 1 1
32 A
IAB703A 0·3 m length IAB705A 0·5 m length IAB710A 1 m length IAB720A 2 m length IAB730A 3 m length IAB750A 5 m length
16 A
IAB603A 0·3 m length IAB605A 0·5 m length IAB610A 1 m length IAB620A 2 m length IAB630A 3 m length IAB650A 5 m length
With flex to female GST connector
IAB610B 1 m length IAB620B 2 m length IAB630B 3 m length
43
Rewirable Rewirable GST GST 3 Blank socket interconnect interconnect interconnect interconnect Blank module male male male end endcap cap male
4 4socket socketin-feed in-feedmodule module 3 socket 3 socket module module TM
End view
TM 37·9 EndEnd view view Intersoc-R desk modules
Intersoc-R desk modules
technical 37·9 37·9
protection, BS sockets, end caps and interlinks
information
60
214·5 411·5 411·5
2323
60 60
5050
6767
n Under-desk dimensions (mm) 3 socket module End view Rewirable Rewirable GST 2 socket in-feed module GST 4 socket in-feed module Rewirable GST GST Rewirab interconnect interconnect Blank interconnect interconnect Compact and interconnect interconnectinterconnec intercon Blank 37·9 feed unit female female female female socket cket module module 2 socket 4 in-feed 4socket socket module module Feed unit male male male endend capcap male 2 socket in-feed module module 4 socket 4 socket in-feed in-feed module module GST 214·5 214·5
60
IAC5P2F
60
214·5
60 60
411·5
291·5 156·5 156·5
276·5 276·5
291·5 291·5
411·5 411·5
2 socket in-feed module
291·5
60
60
and technical information p. 42-45 156·5 156·5
272·5 272·5
2 socket module
460socket module
5050
60
Pack
1 1 1 1
32 60 60 174·5
60
2 socket 214·5 module
IAB5P4F Grey – 2 P + E IAC5P4F Green – 2 P + CE 32
291·5 77·5 77·5
291·5 60 272·5
60
60
156·5
4 socket modu
60
GST interco Blank 156·5 77 Protection modu male end cap
60
60
75
174·5 411·5
Protection mod
60
60
MCB, RCD protection module
12
Interconnection
174·5 Protection module
MCB, RCD protection module 276·5
67
50
MCB, GST RCD protection module Rewirable interconnect interconnect female female
1 : 84·5 mm depth
156·5
50
23
276·5
291·5
60
2 socket module
End view
75 module 4 socket
110·5
115·5
174·5 50
174·5
115·5
60
156·5
Protection module
75
272·5
Interconnection
60 77·5
50 115·5 MCB, RCD protection module
60
Protection module
Interconnection
60 50 174·5
115·5
All dimensions (mm) are nominal
44
50
115·5 GST 60 interconn female
60 60
32
291·5
2 socket module
32
60
on module
4 socket GST in-feed interconnec Blank 411·5 male end cap Protection module 2 socket module 4 socket module 75 Interconnection Interconnection
Fixed – Rotatable – end view end End view view End view 411·5
4 socket module
60
214·5 272·5 4 socket in-feed module R GST interconnect 75 75 110·5 110·5in fe female 411·5
60 MCB, RCD protection module1 50 23 module 4 socket in-feed 115·5
60
2 socket module
50
60
60
m
2 socket in-feed module
60
411·5 2 socket in-feed module 174·5
male
115·5 60 Rewirable 156·5 GST 37·9 32 50 50 interconnect interconnect Blank 2 socket module77·5 77·5 Interconnection GST 115·5 115·5 male male end cap interconnect Protection module End view 60 156·5 female 4 socket module 60
3 gang fixed 90° grey – IS 1293
4 gang fixed 90° grey – IS 1293 End view
R
60
174·5 174·5 4 socket Grey in-feed IAB5P3F – 2module P protection +E MCB, RCD module IAC5P3F Green – 2 P + CE
3 socket module
GST
50interconnect67 in 67
12
1
End view Protection Protection module module
60
2 gang fixed 90° – IS 1293
1 60 IAB5P2F Grey – 2 P + E 291·5 60 1 IAC5P2F Green – 2 P + CE
dule
156·5
Cat. Nos. 6protection Aprotection Indianmodule socket modules 60 MCB, MCB, RCD RCD module
Blank 50 end cap
1 43socket socketmodule module Rewirable GST Rewirab GST interconnect intercon interconnect interconnec female female female female 4 socket in-feed module
156·5 2 socket in-feed module
view The Intersoc 32End A under-desk range is a complete modular power system Intersoc offers a wide range 115·5 of115·5 international socket options 60 shuttered electrical The Intersoc 32 modular system features safe 2 socket in-feed module 4 socket in-feed module connections and a robustly designed rigid joint between modules All modules connect with single push-fit action and autoMCB, lock RCD protection module
1
4 socket 4 socket module module 60 2 socket in-feed module Interconnection Interconnection 411·5
32
Protection Protection module module 60 60 6060 Dimensions 60 60
12 12
4 socket in-feed module
End view 2 socket 2 socket module module
EndEnd view view 32 32
110·5 110·5
2 socket module
IAB5P4F 60
ule e
7575
n Testing and accreditation
n British Standards BS 6396 : 2008 + A1 2015 Electrical Systems in Office Furniture and Educational Furniture Specification BS 7671 : 2018 incorporating amendment No. 3 : 2015. Requirements for Electrical Installation (IET Wiring Regulations 18th Edition) Electricity at Work Regulations 1989
Independently approved by Intertek Complies with BS 5733 and relevant parts of BS 1363-2 Manufactured within an approved ISO 9001 : 2015 and ISO 14001 : 2015 facility Assessed quality assurance certificate No. 2029
up to 32 A 250 V ~ 50 Hz
Conductor resistance at 20°C Fixed Rotatable 2 socket module 4 socket module
0·8 mΩ 1·6 mΩ
0·9 mΩ 1·7 mΩ
1·5 m V/A 3·0 m V/A 4·0 m V/A
(depending on device)
In-feeds : 16 A +1·5 mm2 32 A +4 mm2 Interconnections : 16 A/32 A +1·5 mm2 +4 mm2
(depending on device)
In-feeds : 16 A +1·5 mm2 32 A +4 mm2 Interconnections : 16 A/32 A +1·5 mm2 +4 mm2
Individually fused at 5A 3·15 A
Regulation 543·7 has particular importance when there is a requirement for a quantity of information technology equipment being supplied from a final circuit in a location where the sum of their protective currents exceeds 10 mA in normal use. Due to current in the protective conductor arising from the use of IT equipment, there is a requirement to provide mechanically protected 4 mm2 conductor (543·7·203 (ii)). Intersoc achieves this when wired in accordance with the installation sheets by providing mechanically protected 5 mm2 protective conductors within the product
Earth fault loop impedance
The standard requires individual socket fusing (as per the table below)
Special note should be taken of regulation 543·7 within BS 7671 : 2018 - Earthing requirements for the installation of equipment having high protective conductor currents
2·0 m V/A 29 m V/A/m 11 m V/A/m
1·5 mΩ 3·0 mΩ 4·0 mΩ
A note on individual socket fusing – BS 6396 Compliance :
Meets the requirements of BS 7671 : 2018 The Health and Safety Executive states that installations which conform to the standards laid down in BS 7671 : 2018 are regarded by the HSE as likely to achieve conformity with the relevant parts of the Electricity at Work Regulations 1989
4·0 m V/A 29 m V/A/m 2·0 m V/A 11 m V/A/m
2 socket module 4 socket module Protection module
For compliance with this standard, socket outlet configurations of up to 4 outlets should be individually fused at 5 A and up to 6 outlets individually fused at 3·15 A
Total number of sockets 2, 3 or 4 sockets 5 or 6 sockets
Volt drop Live and neutral 2 socket module 4 socket module Protection module
Below is a brief outline of the main criteria within the standards : BS 6396 : 2008 + A1 2015 was published with regard to the use of electrical equipment within general office and educational furniture This standard sets out in its scope the use and testing of electrical socket outlets and associated wiring when used together with a 13 A BS 1363 fused plug for mains supply and makes provision for the routing of cables through furniture
Electrical test data Rated current Rated voltage Frequency
Health & Safety Legislation
Material specification Module housing heat resistant ABS Socket outlets polycarbonate Busbars high conductivity copper CW004A (C101) Other metalwork phosphor bronze CW451K (PB102), CW452K (PB103) brass CW507L (CZ107), CW508L (CZ108) high conductivity copper CW004A (C101)1
2·0 mΩ 29 mΩ/m 2·0 mΩ 11 mΩ/m
1 : European grades with nearest British Standard shown in brackets
4·0 m V/A 29 mΩ/m 11 mΩ/m
Mechanical data Number of conductors Busbar conductor cross-sectional area 16 A rewirable in-feed terminal capacity 32 A rewirable in-feed terminal capacity
3 5 mm2 10 mm2 10 mm2 All dimensions (mm) are nominal
45
Intersoc-RTM desk modules installation and configuration n Installation To connect and disconnect Intersoc modules
1. Connection / disconnection to be made by a competent person 2. Before connecting modules ensure they are the correct way up and in line 3. Push modules together one at a time 4. Modules self-lock when fully pushed together 5. To disconnect modules slide green latch to unlock module and pull apart 6. Always end module run with blank end cap or interconnect
Module self-locking latch
Underside of modules shown
To fix modules to surface 1. I nsert through all fixing holes no. 8 pozi-pan screw or M4 bolt to required length 2. Tighten screw / bolt down to mounting surface
Slide green latch
Blank end cap
2 socket module
16 A 4 socket in-feed module
All dimensions (mm) are nominal
46
n Product configuration
1. Select the type of distribution system - standard, or low noise / clean earth 2. Select the means of powering the system - cable or powertrack tap-off 3. Select the type of in-feed module to match the cable capacity - 16 A or 32 A 4. Select the means of protection 5. Select the number of socket modules from the 2, 3 or 4 gang range (individually fused or unfused) 6. Select fixed or rotatable sockets 7. Select the interconnection units if required 8. Finish system with the end cap (All modules push fit and lock together on-site or can be factory assembled to customer requirement)
iiiiiil
Floor grommet
llllllllllllllllllllllllll llllllll lllllllllllllll Underfloor powertrack
1
2
l l ll ll
lllll 32 A in-feed connected to tap-off and left underfloor until required
l l ll
l
l l ll
Tap-off
llll l
lllllllllllllllll
lllllll
Raised floor
ll l l ll l l l l
l l ll
In-feed and power module push together and self-lock when fully pushed home
Tap-off and in-feed pulled through floor grommet after testing and when required
All dimensions (mm) are nominal
47
ON-DESK
power and data for
modern workspaces
ON-DESK RANGE BRINGS POWER, DATA AND RAPID USB CHARGING TO THE MODERN WORKSTATION With clean lines and a stylish aluminium and mirror white finish, Electrak on-desk’s ergonomic design blends in perfectly with contemporary office design schemes and enhances the functionality of the desk space. 48
Tailored to your
requirements Configuring on-desk modules to your exact requirements couldn’t be simpler. Select any combination of power sockets and USB charging modules, and further enhance functionality with plug and play data solutions or Euro modules. Legrand’s modular wiring accessories, including a range of AV solutions, can also be incorporated.
Putting ‘personal’ back into desk power and data… Intersoc on-desk can be tailored to the demands of any workstation
RAPID USB CHARGING
HIGH PERFORMANCE DATA
Intelligent twin USB modules offer a high specification, rapid charge facility that keeps your mobile devices ready should you need to work on the move. Up to two devices (e.g. tablet and smart phone) can be simultaneously charged at a faster rate than common, lower output chargers.
On-desk offers plug and play CAT 5e and CAT 6 data options or CAT 6A keystone jack modules for higher performance. Euro module options are also available to accommodate a customer’s specific data requirements. The innovative design of Intersoc on-desk enables data cables to neatly feed through the rear of the unit (see below).
Watch the on-desk video at www.youtube.com/LegrandtvUK The entire Electrak system is powered by a reliable busbar backbone, from powertrack right through to on-desk modules.
Power is fed to the on-desk unit via a choice of 13 A pre-wired plug, GST connector or an Intersoc-R under-desk connector.
CAT 5e and CAT 6 data outlets are fed neatly from the rear of the unit via simple RJ45 connection (patch leads not supplied).
49 49
RELIABLE DESKTOP
CONNECTIVITY ON-DESK... DELIVERING POWER, DATA AND RAPID USB CHARGING TO THE MODERN WORKPLACE The fast pace of modern work practices combined with the need for instant connectivity is placing an ever greater reliance on the use of multiple devices, whether it be at our workstation or whilst we're on the move. The new range of Electrak on-desk modules offers a convenient answer to the growing demand for user-specific desk power and data access.
50
CAT 5e / 6 / 6A RJ45 outlets
Rapid dual USB charging
BS and International socket options
RELIABLE BUSBAR BACKBONE Building on the success of the Electrak system, on-desk is powered by a busbar backbone which provides a reliable electrical connection.
51
On-desk modules
Pre-wired with 3 m flex and BS 1363 plug
Pre-wired with 1·5 m flex and GST connector
Pre-wired with 1·5 m flex and Intersoc-R connector
Cat. Nos.
Cat. Nos.
Cat. Nos.
2 x sockets individually fused at 3·15 A
PA3320AA
PB1320AA
PD1320AA
3 x sockets individually fused at 3·15 A
PA3330AA
PB1330AA
PD1330AA
4 x sockets individually fused at 3·15 A
PA3340AA
PB1340AA
PD1340AA
2 x sockets individually fused at 3·15 A plus 1 x rear pluggable CAT 5e / CAT 6 RJ45 outlet
PA3320AB
PB1320AB
PD1320AB
2 x sockets individually fused at 3·15 A plus 2 x rear pluggable CAT 5e / CAT 6 RJ45 outlets
PA3320AC
PB1320AC
PD1320AC
2 x sockets individually fused at 3·15 A plus 1 x rear pluggable data USB outlet
PA3320AD
PB1320AD
PD1320AD
PA3320AE
PB1320AE
PD1320AE
PA3320AF
PB1320AF
PD1320AF
PA3320AG
PB1320AG
PD1320AG
Description
20AA
PA33
120 30AA
PA33 107
120 172
20AA
PA33
40AA
PA33 AA
3320
view etric 1:2 Isom : Scale
20AB
PA33
180 232
30AA
PA33
240 20AC
PA33
292
5 152· A5 40A4· PA33 20
.5
7 ( 10
40AA
PA33
PA
t view :2 Fron : 1 Scale
)
152
AB 3320
AD
view etric 1:2 Isom : Scale
20 PA33
2 x sockets individually fused at 3·15 A plus 2 x rear pluggable data USB outlets
175 3 ( 28
227
)
t view :2 Fron : 1 Scale
view etric 1:2 Isom : Scale
20AE
20AC
PA33
2 x sockets individually fused at 3·15 A plus 1 x CAT 6A RJ45 outlet with 3 m data lead
PA33
5
152·
5 204·
PA33
2 x sockets individually fused at 3·15 A plus 2 x CAT 6A RJ45 outlets with 3 m data leads
175
20AG
view etric 1:2 Isom : Scale
20AD
PA33
t view :2 Fron : 1 Scale
20AF
view etric 1:2 Isom : Scale
PA33
227
Fixings Description
20AE
PA33
Desk clamp
t view :2 Fron : 1 Scale
Cat. No. 175 227
t view :2 Fron : 1 Scale
52
0546 99
230 282
ew
20AF
PA33
Pre-wired with 3 m flex and BS 1363 plug
Pre-wired with 1·5 m flex and GST connector
Pre-wired with 1·5 m flex and Intersoc-R connector
Description
Cat. Nos.
Cat. Nos.
Cat. Nos.
2 x sockets individually fused at 3·15 A plus carrier to accept 1 x Euro Module (25 x 50 mm)
PA3320AK
PB1320AK
PD1320AK
2 x sockets individually fused at 3·15 A plus carrier to accept 2 x Euro Modules (50 x 50 mm)
PA3320AL
PB1320AL
PD1320AL
3 x sockets individually fused at 3·15 A plus 1 x rear pluggable CAT 5e / CAT 6 RJ45 outlet
PA3330AB
PB1330AB
PD3330AB
3 x sockets individually fused at 3·15 A plus 2 x rear pluggable CAT 5e / CAT 6 RJ45 outlets
PA3330AC
PB1330AC
PD1330AC
3 x sockets individually fused at 3·15 A plus 1 x rear pluggable data USB outlet
PA3330AD
PB1330AD
PD1330AD
3 x sockets individually fused at 3·15 A plus 2 x rear pluggable data USB outlets
PA3330AE
PB1330AE
PD1330AE
2G 6A Indian non-switched – 1·5 ISOC and no data
–
–
PD1P20AA
2G 6A Indian non-switched – 1·5 ISOC and 1 x C5/6
–
–
PD1P20AB
2G 6A Indian non-switched – 1·5 ISOC and 2 x C5/6
–
–
PD1P20AC
view etric 1:2 Isom : Scale
AK
20 PA33
view etric 1:2 Isom : Scale
20AL
PA33
160 212 AB 3330
PA
20AK
PA33
t view :2 Fron : 1 Scale
185 237
30AB
PA33
t view :2 Fron : 1 Scale
AL
20 PA33
30AB
PA33
30AE
PA33
30AB
PA33
172 120
30AE
PA33
205 152.5
Notes: Other options are available to special order. Contact us on +44 (0) 345 605 4333 CAT 5e / CAT 6 outlets have a rear facing RJ45 that will accept either CAT 5e or CAT 6 data cabling (no data cabling is included with the product) CAT 6A outlets are supplied with 3 m pre-wired lead and performance certificate The data USB outlets have 2a27short flying lead at the rear for USB connection to the PC (no additional data cabling is included with the product) 75 accept Euro Modules will be supplied with apertures at the rear for the passing of data or AV cables Units supplied with carriers1to
53
On-desk modules with twin outlet USB charger
Pre-wired with 3 m flex and BS 1363 plug
Pre-wired with 1·5 m flex and GST connector
Pre-wired with 1·5 m flex and Intersoc-R connector
Cat. Nos.
Cat. Nos.
Cat. Nos.
1 x unfused socket plus twin outlet USB charger
PA3012AA
PB1012AA
PD1012AA
2 x sockets individually fused at 3·15 A plus twin outlet USB charger
PA3322AA
PB1322AA
PD1322AA
3 x sockets individually fused at 3·15 A plus twin outlet USB charger
PA3332AA
PB1332AA
PD1332AA
1 x unfused socket, twin outlet USB charger plus 1 x rear pluggable CAT 5e / CAT 6 RJ45 outlet
PA3012AB
PB1012AB
PD1012AB
1 x unfused socket, twin outlet USB charger plus 2 x rear pluggable CAT 5e / CAT 6 RJ45 outlets
PA3012AC
PB1012AC
PD1012AC
1 x unfused socket, twin outlet USB charger plus 1 x rear pluggable data USB outlet
PA3012AD
PB1012AD
PD1012AD
1 x unfused socket, twin outlet USB charger plus 2 x rear pluggable data USB outlets
PA3012AE
PB1012AE
PD1012AE
2 x sockets individually fused at 3·15 A, twin outlet USB charger plus 1 x rear pluggable CAT 5e / CAT 6 RJ45 outlet
PA3322AB
PB1322AB
PD1322AB
2 x sockets individually fused at 3·15 A, twin outlet USB charger plus 2 x rear pluggable CAT 5e / CAT 6 RJ45 outlets
PA3322AC
PB1322AC
PD1322AC
Description
12AA
PA30
113
115
22AA
PA33
283
32AA
12AA
PA33
PA30
175 227
22AA
PA33
12AC
PA30
AA
32 PA33
12AD
PA30
12AC
PA30
12AE
PA30
view etric 1:2 Isom : Scale
12AD
PA30
207
.5
view etric 1:2 Isom : Scale
AC 3322
PA
7 ) ( 10
AB
22 PA33
12AE
PA30
Fixings Description
Cat. No.
283 230
Desk clamp
0546 99 22AB
PA33
) ( 78
t view :2 Fron : 1 Scale
54 282
Pre-wired with 3 m flex and BS 1363 plug
Pre-wired with 1·5 m flex and GST connector
Pre-wired with 1·5 m flex and Intersoc-R connector
Cat. Nos.
Cat. Nos.
Cat. Nos.
2 x sockets individually fused at 3·15 A, twin outlet USB charger plus 1 x rear pluggable data USB outlet
PA3322AD
PB1322AD
PD1322AD
2 x sockets individually fused at 3·15 A, twin outlet USB charger plus 2 x rear pluggable data USB outlets
PA3322AE
PB1322AE
PD1322AE
2 x sockets individually fused at 3·15 A, twin outlet USB charger plus 1 x CAT 6A RJ45 outlet with 3 m data lead
PA3322AF
PB1322AF
PD1322AF
2 x sockets individually fused at 3·15 A, twin outlet USB charger plus 2 x CAT 6A RJ45 outlets with 3 m data leads
PA3322AG
PB1322AG
PD1322AG
2 x sockets individually fused at 3·15 A, twin outlet USB charger plus carrier to accept 1 x Euro Module (25 x 50 mm)
PA3322AK
PB1322AK
PD1322AK
2 x sockets individually fused at 3·15 A, twin outlet USB charger plus double carrier to w accept 2Fronxlet vi: eEuro Modules (50 x 50 mm) 1:2
PA3322AL
PB1322AL
PD1322AL
–
–
PD1P22AA
–
–
PD1P22AB
–
–
PD1P22AC
Description
view etric 1:2 Isom : Scale 22AD
PA33
207
22AE
) ( 78
PA33
.5
view etric 1:2 Isom : Scale
283
view etric 1:2 Isom : Scale
22AF
PA33
22AD
PA33
t view :2 Fron : 1 Scale
) ( 78
230
282 22AG
PA33
391 230
22AE
PA33
t view :2 Fron : 1 Scale
22AK
PA33
view etric 1:2 Isom : Scale
22AG
PA33
Sca
22AF
PA33
2G 6A Indian non-switched – 2 USB : 1·5 m ISOC and no data 7 ( 10
)
215
2G 6A Indian non-switched – 2 USB : 1·5 m ISOC and 1 x C5/6 7 ( 26
227 175
t view :2 Fron : 1 Scale
)
22AK
PA33
2G 6A Indian non-switched – 2 USB : 1·5 m ISOC and 2 x C5/6
Notes:
260 207.5
Other options are available to special order. Contact us on +44 (0) 345 605 4333 CAT 5e / CAT 6 outlets have a rear facing RJ45 that will accept either CAT 5e or CAT 6 data cabling (no data cabling is included with the product) CAT 6A outlets are supplied82 with 3 m pre-wired lead and performance certificate 2 The data USB outlets have 2a30short flying lead at the rear for USB connection to the PC (no additional data cabling is included with the product) Units supplied with carriers to accept Euro Modules will be supplied with apertures at the rear for the passing of data or AV cables
55
On-desk modules technical information Isometric view 1:2
PA3320AD
Scale : PA3320AC
78
n On-desk dimensions (mm)
91
175
PA3320AE
Isometric view Scale : 1:2
227
PA3320AD PA3320AC 90 90
3320AA
PA3322AA
Isometric view Scale : 1:2
To suit desk thickness of 6–40 mm
To suit desk thickness of 6–40 mm
54
152·5 204·5 PA3320AF
35
PA3320AE Front view Scale:
PA3320AA
PA3320AD
1:2
PA3330AA
175 227 120
Isometric view Scale : 1:2
172
PA3322AA PA3320AA
CARTON LABEL POSITION DETAIL
PA3340AA
PA3320AG
PA3320AF
Front view Scale: 1:2
PA3320AE
175 227
Isometric175 view Scale : 227 1:2
PA3320AK
PA3330AA PA3320AG PA3322AA
Front view Scale: 1:2
Isometric view Scale : 1:2
PA3320AL
180
PA3320AF
232
230
Isometric view Scale PA3340AA : 1:2
282
PA3320AK PA3330AA
Front view Scale: 1:2
PA3320AG
240 292
160
PA3320AB
212 PA3340AA
PA3320AL Front view Scale: 1:2
PA3320AK
152·5 204·5
185 237
All dimensions (mm) are nominal
Front view Scale: 1:2
56
PA3320AB
Front view Scale: 1:2
PA3320AL
n On-desk dimensions (mm) (continued)
n Testing and accreditation
PD1P22AA 227 175
Complies with BS 5733 and relevant parts of BS 1363-2 Manufactured within an approved ISO 9001 : 2015 and ISO 14001 : 2015 facility
n BS 6396 : 2008 + A1 2015 Electrical Systems in Office Furniture and Educational Furniture Specification
PD1P22AB 260 207.5
Below is a brief outline of the main criteria within the standards : BS 6396 : 2008 + A1 2015 was published with regard to the use of electrical equipment within general office and educational furniture. This standard sets out in its scope the use and testing of electrical socket outlets and associated wiring when used together with a 13 A BS 1363 fused plug for mains supply and makes provision for the routing of cables through furniture The standard requires individual socket fusing (as per the table below)
PD1P22AC 282 230
Total number of sockets 2, 3 or 4 sockets 5 or 6 sockets
Individually fused at up to
5A 3·15 A
BS 6396 : 2008 + A1 2015 requires RCD protection for electrical sockets Material specification Module housing Module fascia Socket outlets End caps
PD1P20AA 172
aluminium / PVC polycarbonate / ABS polycarbonate ABS
120
USB charger module specification
PD1P20AB 205 152.5
Supply voltage (nominal) Supply current Power consumption (max.) Frequency Output voltage Output current Output power Over current protection Output connectors Current per socket
230 V (AC) 1·3 mA 0·3 W 50 Hz +5·0 V ± 0·25 (DC) 3·1 A 15 W (max.) 3·8 A (max.) 2 x USB Type A sockets 2·1 A (max.)
PD1P20AB 227 175
All dimensions (mm) are nominal
57
ELECTRAK IN-DESK
enhancing the workstation
IN-DESK BRINGS STYLE AND FLEXIBILITY TO THE WORKSTATION Made from high quality brushed stainless steel, In-desk is designed to complement the aesthetic of modern workspaces, giving users power when they need it and minimal, sleek design when they don’t.
58
With the simple touch of a button, the unit elegantly rises from the desk in a smooth action to reveal either a traditional twin socket arrangement or a single socket with twin USB outlets for charging mobile devices.
EASY INSTALLATION The Electrak In-desk range is pre-wired with a BS plug, GST or Intersoc-R connector for simple tool-free electrical connection.
MINIMAL AND DISCREET When power isn’t required, the ultra-slim brushed stainless steel cover closes to fit discreetly into the desktop.
59
POWER SET FREE
In-desk units
wireless charging
Legrand’s Qi certified induction charger can be easily installed into desks, tables and other furniture – allowing Qi enabled smartphones and other mobile devices to be charged simply by placing them on top. Charging has never been more simple. Extra flat, supplied with a micro USB/USB cable and a USB mobile power supply (Cat. No. 077580).
POPA3012AA
POPA3020AA
077580
Dimensions and technical information p. 61 Classification of In-desk flush-mounting boxes according to NFC 61-314 / EN 60670-1 : 2005 + A1 : 2013 Protection against mechanical impact: IK 07 Degree of ingress protection: IP 30 cover open, IP 40 cover closed
Pack
Cat. Nos.
In-desk units
USB power supply for recharging portable devices Conforms to IEC 62684-2011-01 Consumption in passive mode < 0.1 W Double USB sockets - 5 V - 2400 mA For fast charging telephones, smartphones, MP3/MP4 players and tablet PC British standard socket outlet: shuttered for child safety ASTA licenced Conforms to BS 1363 Part 2 Unit with single socket and twin USB outlets
1 1 1
POPA3012AA Unit with 3m lead and BS 1363 plug POPB1012AA Unit with 1.5m lead and GST connector POPD1012AA Unit with 1.5m lead and Intersoc-R connector
1 1 1
Unit with twin sockets
POPA3020AA Unit with 3m lead and BS 1363 plug POPB1020AA Unit with 1.5m lead and GST connector POPD1020AA Unit with 1.5m lead and Intersoc-R connector
Wireless charging unit
Qi certified induction charger
1 077580 1000 mA wireless charger for furniture Wireless charging for Qi enabled smartphones and other mobile devices Designed for mounting horizontally into furniture Supplied complete with required accessories for installation into furniture
60
In-desk units and wireless charging unit technical information In-desk units
Wireless charging unit - 1000 mA
Technical characteristics
Technical characteristics
Electrical characteristics
Electrical characteristics
Earthing system
R < 0.05 Ohms
Nominal input voltage
110 - 230 V ~
Resistance to vertical load applied through small surface area
1500 N cover open 3000 N cover closed
Nominal output voltage
5V~
Rated voltage
U 500 V - R > 5 MOhms
Frequency
50 - 60 Hz
Electric strength
2000 V
Maximum input current
150 mA
Protection class
II - low voltage
Maximum output current
1000 mA
Standby consumption
< 0·07 W
Energy efficiency
> 85%
Protection class
II - low voltage
Material: Halogen free material, fire proofed and no propagator of the flame Resistant to corrosion and to temperature changes Finish: Brushed Stainless steel, zamak nickel coating Safety: You must earth the system Cleaning: The exterior should only be cleaned using a damp cloth (avoid contact with the active parts). Do not use abrasive detergent Installation
Climate characteristics Storage temperature : 20°C to +70°C Operating temperature : 0°C to +45°C
108mm
Standards and approvals WPC QI BS EN 62479 ICNIRP
(1)
131mm(1)
1: +/- 1 mm
Mechanical characteristics Impact resistance : IK 08 Resistance to ingress of solid bodies and liquids : • IP 43 • IP 44 for upper part installed on furniture
Minimum distance from to the edges of the furniture: 70 mm
Material characteristics ABS Halogen free UV resistant Self-extinguishing : • 750°C / 30 s for parts made of insulating materials holding live parts in place • 650°C / 30 s for other insulating components
20 mm 15 mm < e < 40 mm
74.8mm
Dimensions
Y
Average charging time for a smartphone equipped with an induction receiver 80% charge : < 2 hrs 100% charge : < 2 hrs 45 mins
142.5mm
120mm
D
Positioning of the fixing supports X
1
2
3
4
All dimensions (mm) are nominal
61
BUSCOM TRUNKING a unique
power & data backbone
Buscom is at the heart of Electrak’s lighting control solutions... It provides a flexible and simple alternative to cabled installations.
THE HEART OF YOUR LIGHTING CONTROL SYSTEM Installing a matrix of Buscom trunking creates an accessible power and communications backbone. The backbone can be tapped into at any point to facilitate instant connection to power and control circuits. Buscom incorporates an integral shielded twisted pair, and is suitable for use with any lighting control protocol, including: KNX, LonWorks and DALI.
MODULAR. FLEXIBLE. SIMPLE. Trunking lengths simply push fit together, saving time and money on installation. With cable terminations only required for power and control circuits in the feed unit, Buscom delivers a plug and play solution that allows for future lighting layout changes to be made quickly and efficiently. 62
BUSCOM ADDS A NEW DIMENSION TO LIGHTING BUSBAR
n
n
Buscom extends the unquestionable plug and play advantages from the power circuit to the control circuit. n
This unique system for distributing lighting control signals delivers unrivalled flexibility, regardless of the location of the intelligence... n
ower and communications within P a single trunking system uitable for use with any lighting S control protocol, including: KNX, LonWorks and DALI odular, flexible system which is M quick and simple to install and adapt educed potential points of failure R in comparison with traditional wiring installations
THE INTELLIGENT SOLUTION INTELLIGENCE IN THE PANEL
Lighting control modules located in a central cabinet are connected to the Buscom system via communication circuits. Control signals are then distributed along the trunking run and made available at any tap-off outlet.
INTELLIGENCE IN THE BUSBAR
Integrating lighting control technology into Buscom trunking is particularly effective for DALI control. Each trunking run converts to an individual DALI network into which luminaires can tapin at any point.
INTELLIGENCE IN THE LCU
Lighting control units (LCUs) are mounted onto and plugged into Buscom trunking, providing a hub for multiple luminaires and switching devices to plug into. Buscom’s integrated communication bus provides the backbone network to control all devices. Visit www.legrand.co.uk for more information
63
Electrak® 30 2P + E buscom trunking power and communication distribution
CCA3145C
CCA2145C
CCA14RFC
CCA14LFC Dimensions and technical information p. 68-73 Integral communication bus suitable for KNX, Lonworks, DALI protocols, etc. 25 A and 40 A systems IP 4X ingress protection Fast installation (trunking push fits together in seconds). High quality materials
Pack
Cat. Nos. Electrak
30 2P + E with comms
2P + E buscom trunking system with integral communications bus circuit Socket outlets colour coded white Trunking lengths
Pack
Cat. Nos. Electrak
30 2 P + E without comms
2P + E busbar (power only) trunking system Socket outlets colour coded white Trunking lengths
Trunking lengths push fit into each other, and feed units. Trunking lengths can be suspended using the various bracket options
Trunking lengths push fit into each other, and feed units or flexible lengths. Trunking lengths can be surface mounted suspended using the various bracket options
Length Tap-off Weight 25 A (m) outlets (kg)
Length Tap-off Weight 25 A (m) outlets (kg)
1 BBA3145C 3 1 BBA2145C 2
1 CCA3145C 3 1 CCA2145C 2
40 A
6 4·47 4 3·27 6 4·57 4 3·36
C L N PE
Feed units (with comms)
Feed units come with 2 x 25 mm Ø and 2 x 16 mm Ø cable entry holes and single screw cable terminals for power and data Left feed units are supplied with right end stop Right feed units are supplied with left end stop
64
1 BBA14LFC 1 BBA14RFC 1 CCA14LFC 1 CCA14RFC
25 A left 25 A right 40 A left 40 A right
1 BBA3145 3 1 BBA2145 2
1 CCA3145 3 1 CCA2145 2
40 A
6 4·47 4 3·27 6 4·57 4 3·36
Weight (kg)
1·22 1·49 1·27 1·49
L N PE
Feed units (without comms – power only) Feed units come with 2 x 25 mm Ø cable entry holes and single screw cable terminals Left feed units are supplied with right end stop Right feed units are supplied with left end stop Suspended
Suspended
1 BBA14LF 1 BBA14RF 1 CCA14LF 1 CCA14RF
25 A left 25 A right 40 A left 40 A right
Weight (kg)
1·22 1·49 1·27 1·49
Electrak® 32 4P + E (dual circuit) buscom trunking power and communication distribution
CCC3145C
CCC2145C
CCC14RFC
CCC14LFC Dimensions and technical information p. 68-73 Integral communication bus suitable for KNX, Lonworks, DALI protocols, etc. 25 A and 40 A systems IP 4X ingress protection Fast installation (trunking push fits together in seconds). High quality materials
Pack
Cat. Nos. Electrak
32 4P + E (dual circuit) with comms
Pack
Cat. Nos. Electrak
32 4P + E (dual circuit) without comms
Dual circuit buscom trunking system with integral Dual circuit busbar trunking system communications bus circuit Socket outlets colour coded white Socket outlets colour coded white Trunking lengths Trunking lengths Trunking lengths push fit into each other, and Trunking lengths push fit into each other, and feed units. Trunking lengths can be suspended feed units. Trunking lengths can be suspended using the various bracket options using the various bracket options Length Tap-off Weight 25 A (m) outlets (kg) Length Tap-off Weight 25 A (m) outlets (kg) 1 BBC3145 3 6 4·77 1 BBC3145C 3 6 4·77 1 BBC2145 2 4 3·47 L2 C N2 1 BBC2145C 2 4 3·47 L2 40 A L1 N2 N1 40 A 1 CCC3145 3 6 4·97 L1 PE N 1 1 CCC3145C 3 6 4·97 1 CCC2145 2 4 3·61 PE 1 CCC2145C 2 4 3·61
Feed units (with comms)
Feed units come with 2 x 25 mm Ø and 2 x 16 mm Ø cable entry holes and single screw cable terminals for power and data Left feed units are supplied with right end stop Right feed units are supplied with left end stop Suspended
1 BBC14LFC 1 BBC14RFC 1 CCC14LFC 1 CCC14RFC
25 A left 25 A right 40 A left 40 A right
Weight (kg)
1·29 1·52 1·38 1·61
Feed units (without comms – power only) Feed units come with 2 x 25 mm Ø cable entry holes and single screw cable terminals Left feed units are supplied with right end stop Right feed units are supplied with left end stop Suspended
1 BBC14LF 1 BBC14RF 1 CCC14LF 1 CCC14RF
25 A left 25 A right 40 A left 40 A right
Weight (kg)
1·29 1·52 1·38 1·61
For the full Buscom range please see the Lightrak lighting control catalogue, visit www.legrand.co.uk/downloads
65
Electrak® buscom trunking tap-offs power and communication distribution
DDJ45 DDJ45C
DDK4F
Dimensions and technical information p. 68-73
Pack
Cat. Nos.
Tap-off units with comms
Pack
Cat. Nos. Tap-off
units without comms (power only)
Tap-offs with comms can only be plugged into outlets that have the comms facility 16 A unfused tap-off units Pre-wired tap-off units to pick up L1+N1 or L2+N2, colour coded white
Power only tap-offs can plug into any tap-off outlet 16 A unfused tap-off units Pre-wired tap-off units to pick up L1+N1 or L2+N2, colour coded white
1 1 1 1
DDE43C 3 L1 + N1 DDE45C 5 DDJ43C 3 L2 + N2 DDJ45C 5
1 1 1 1
Length Fixed Weight (m) polarity (kg)
0·5 0·6 0·5 0·6
1 1 1 1
DDE43 3 L1 + N1 DDE45 5 DDJ43 3 L2 + N2 DDJ45 5
13 A fused tap-off units re-wired tap-off units to pick up L1+N1 or L2+N2, P supplied with BS 1362 fuse, colour coded white Length Fixed Weight (m) polarity (kg)
DDE43FC 3 L1 + N1 DDE45FC 5 DDJ43FC 3 L2 + N2 DDJ45FC 5
0·5 0·6 0·5 0·6
1 1 1 1
Length Fixed Weight (m) polarity (kg)
0·5 0·6 0·5 0·6
13 A fused tap-off units re-wired tap-off units to pick up L1+N1 or L2+N2, P supplied with BS 1362 fuse, colour coded white Length Fixed Weight (m) polarity (kg)
DDE43F 3 L1 + N1 DDE45F 5 DDJ43F 3 L2 + N2 DDJ45F 5
0·5 0·6 0·5 0·6
Tap-off units without comms – rewirable 16 A unfused tap-off units Rewirable tap-off units to pick up required circuit, colour coded white, can plug into any tap-off outlet
1 1
DDF4 DDK4
Fixed Weight polarity (kg)
L1 + N1 L2 + N2
0·14 0·14
13 A fused tap-off units Rewirable tap-off units to pick up required circuit, supplied with BS 1362 fuse, colour coded white, can plug into any tap-off outlet
66
1 1
DDF4F DDK4F
Fixed Weight polarity (kg)
L1 + N1 L2 + N2
0·14 0·14
ElectrakÂŽ buscom trunking accessories fixings and ancillary items
EEC348
EEC356
EEB340
EEB344
EEA308
EEA312
EEA328
EEA324
EEC352
EEC364
Dimensions and technical information p. 68-73 Brackets are manufactured from robust galvanised steel, ensuring that the entire installation can be expected to stand up to all normal site conditions
Pack
Cat. Nos. Fixings
Pack
1
EEA308
Trunking suspended fixing bracket
1
1
EEA312 Trunking suspended fixing bracket c/w cable duct stirrup. Used when running cable duct on top of buscom trunking
EEC356 2 m empty length for adjusting the length at the end of a run (to be cut)
1
EEC364 Joint sleeve is used if load is hung off trunking joint or near when joint is centre of a fixing span
1
EEA324
1
EEC366
Left hand end stop spare
1
EEA328 Luminaire 45 mm edge suspension fixing bracket (clip on)
1
EEC368
Right hand end stop spare
1
EEB340
1
EEB344 Closed ring on luminaire
1
EEC348 Cable duct 3 m long x 50 mm(w) x 13 mm(h)
1
EEC357
Joint bracket cable duct
1
EEC352
Cable duct fixing bracket
Luminaire suspension fixing bracket
Cat. Nos. Ancillary
items
Open hook luminaire suspended bracket
For the full Buscom range please see the Lightrak lighting control catalogue, visit www.legrand.co.uk/downloads
67
Electrak® buscom trunking technical information n Standards
Electrical test data
ASTA approved to BS EN 61439-6 Designed to meet the requirements of BS EN 61534-22 : 2014 Manufactured within an approved ISO 9001 : 2015 and ISO 14001 : 2015 Assessed Quality Assurance Certificate No. 10679 Electrak Buscom fully complies with the requirements of BS 7671 : 2018
25 A
Derating factor for Electrak 32 single sided Rated operational voltage (Ue) Rated insulation voltage (Ui) Frequency (f) Rated impulse withstand voltage Busbar resistance (R20) Resistance (R1) Impedance (Z1) Reactance (X1) Protective conductor
40 A
UOM
– 0·8 – 230/400 230/400 V 500 500 V 50 50 Hz 4·0 4·0 KV 3·9 2·7 mΩ/m 4·2 3·0 mΩ/m 4·8 3·4 mΩ/m 2·5 1·6 mΩ/m 1·5 1·5 mΩ/m
± ±
n Buscom trunking options
• L2 • N2 • L • L1 • N • N1 PE PE
Volt drops
Communication bus
Electrak buscom trunking can be used with Electrak’s cost effective lighting control system, Lightrak KNX, or any other systems using control protocols such as KNX, Lonworks, DALI, etc. Electrak’s overhead trunking couples high quality engineering with rigidity of design, and provides power for a variety of applications including lighting, heating and ventilation. The robust easy fix modular system permits loads to be suspended directly from the trunking using Electrak’s various fixing brackets Push fit connection keeps installation costs to a minimum Track lengths simply push fit together
25 A
40 A
UOM
9·0 3·0 22·0 52·0
6·0 2·4 22·0 52·0
mV/A/m mV/A mV/A mV/A
25 A
40 A
UOM
3·0 1·5 2·4 23·0 53·0 16·0 1·0 1·5 35·0
mΩ/m mΩ/m mΩ mΩ mΩ KA KA KA ˚C
25 A
40 A
UOM
2-6 4·0 6·0 1·5 1·5 1·5 16·0 25·0 16·0 4 X
2-6 6·0 16·0 1·5 1·5 1·5 16·0 25·0 16·0 4 X
– mm2 mm2 mm2 mm2 mm2 mmØ mmØ mmØ –
Live and neutral : busbars (R1+R2) Feed unit Tap-off 0·8 m Tap-off 2·0 m Earth fault loop
Impedance : busbar Earth housing Feed unit Tap-off 0·8m Tap-off 2·0m Rated conditional short-circuit current (Icc) Rated short time withstand current (Icw) at 1 sec Rated peak short-circuit current (Ipk) Ambient temperature Mechanical data Number of conductors Busbar conductor cross-sectional area Cable terminal capacity Cable terminal capacity bus Tap-off cable 16 A Tap-off cable 13 A fused Tap-off entry Feed unit entry holes power Feed unit entry holes bus IP rating
4·5 1·5 2·4 23·0 53·0 16·0 0·65 0·975 35·0
Direct protection by enclosure. Indirect protection by protective circuit
n Feed units 25 A rated - max. conductor size 6 mm2 40 A rated - max. conductor size 16 mm2 IP 4X galvanised steel
2 pole + earth + comms
Comms bus Max. conductor size 1·5 mm2 Red + Black All dimensions (mm) are nominal
68
Electrak® buscom trunking technical data
Communication control circuit Type Construction Insulation - conductor Sheath
Bus cable (LSOH) Sheathed 0·5 mm2 copper twisted pair Flame retardant low emission HCL LSOH material
Rated insulation voltage (Ui) (between power circuit and bus)
500 V
Max. bus operating voltage Max. bus operating current Max. conductor resistance (@20˚C) Max. mutual capacitance Material specifications Buscom trunking housing Busbars Busbar insulator Trunking connector / tap-off entry box / cable connector Tap-off housing Trunking connector blades / tap-off blades Feed unit IP 4X Feed unit IP 54 Flexible length conduit Feed unit terminals / earth block Brackets 13 A tap-off, fuse
50 V 0·65 A 73·2 Ω/km 100 nf/km Galvanised steel High conductivity copper Flame retardant LSOH to BS 7211 Flame retardant polycarbonate Flame retardant polycarbonate Copper Galvanised steel ABS Flame retardant LSOH nylon Brass Galvanised steel To BS 1362, ASTA approved
Durability Electrak power and communications distribution systems are well designed and extremely robust. They can be expected to stand up to all normal site conditions. Electrak Buscom has been short circuit strength tested by ASTA Earth fault loop impedance BS 7671 : 2018 require accurate determination of the total earth loop impedance, which must be sufficiently low to allow the protective device to operate within the specified time, which for socket outlets is 0·4 seconds The values relevant to Electrak Buscom for calculating the earth fault loop impedance are shown in the electrical test data table, see opposite Buscom trunking rating in ambient temperatures Average ambient air temperature Rating factor (K1)
25˚C
30˚C
35˚C
40˚C
45˚C
50˚C
1·1
1·05
1
0·95
0·90
0·85
For ambient temperatures other than 35˚C apply the multiplier factor K1 to the rated current Buscom trunking mechanical loading For point loads and evenly distributed loads the maximum weight that can be supported is given below Maximum loading for suspended buscom trunking Fixing distance (m)
1·5
2
2·5
3
3·5
4
Max. point load (deflection = 1/500 x span) (Kg)
20
17
13
12
9
7
Max. distributed load (deflection = 1/500 x span) (Kg)
33
28
22
20
15
12
Max. point load (deflection = 1/350 x span) (Kg)
33
24
18
16
10
9
Max. distributed load (deflection = 1/350 x span) (Kg)
55
40
30
26
16
15
Notes 1. Where trunking joints occur in the middle of the suspension span, and weight is to be suspended from that point, it is recommened to use a strenghting bracket EEC364 over the joint to stop deflection 2. I f the load requirements exceed the above figures, please contact us on +44 (0) 370 608 9020 For design information and technical specification, please contact us on +44 (0) 370 608 9020 Suspension rods and fixings should be of suitable size to carry the weight of both the track and suspended load
All dimensions (mm) are nominal
69
Electrak® buscom trunking dimensions n Fixing dimensions Buscom trunking 3 m 0·5 mspacings outlet spacings 0·5 m outlet 220
195·5 195·5 220
500
3 000 3 000 500
500
500
500
500
500
Buscom trunking 2 m
195·5 195·5 220
500
500
2 000 2 000 500
500
500
500
45
45
32
32
304·5 304·5
500
57
Suspended
Feed unit – left
Feed unit – right
57
209
308
209 517
220
220
All dimensions (mm) are nominal
70
220
End stop – left
10
320
320
209
220 429
517
10
feed unit Single sided system 2 x 16 Ø2 x 16 Ø
57
308
End stop – right
304·5 304·5
Buscom trunking end view
0·5 mspacings outlet spacings 0·5 m outlet 220
500
500
429
209
2 x 25 Ø2 x 25 Ø 52
52
57
13
13
8·5 Ø
108
12
35
1
8·5 Ø 50 8·5 Ø
59
12 95
95
57
8·5 Ø
38
8·5 Ø
130
38
141
7Ø
21 141
82 7Ø
7Ø
163 163
57
7·5
92
60
30
107
1
1
8·5 Ø
125
38 15
M5
8·5 Ø
38
8·5 Ø
77
59
8·5 Ø
70
82
70 Ø 8·5
35
70 13 8·5
39
35
68
53·5
70 6Ø
6 Ø 96
6Ø
30
78
53·5 13
M5
78
6Ø
6Ø 30
Fuse holder 136
6Ø 6 8·5 Ø– 33 mm deep Pre-wired tap-offs 30
78
6Ø
6Ø
39
6Ø 30
78 68
68
96
68
136
Rewirable and phase selection tap-offs – 35 mm deep 96
8·5
39
6Ø
136
68 6Ø 30
78
136
53·5
53·5
70
68
Fuse holder
68
8·5
8·5 6Ø
35
Tap-off Fuse holder
39
35
M5
Fuse holder
39 6Ø
39
68
53·5
6Ø
68
35
68
6Ø
53·5
13
6Ø
70
6Ø
8·5
8·5
96
78
21 Fuse holder
M5
6Ø
Fused tap-off
35
M5
70 70
6Ø 60
70 6 Ø70 60
70
60
68
Fuse holder 39 35
30
38
8·5 Ø
96
70
Tap-off 96 fuse removal M5 M5
21
6Ø 35
Tap-off fuse removal
6Ø 60
M5
Fuse holder 136
8.5 Ø
30 68
fuse removal
Cat. No. EEB340 Open hook
Tap-off 68 fuse removal
30
60
70
70
21 6 Ø
30 30
13
59
59
30
70
6Ø
60
70
12
M5
6Ø
Tap-off fuse removal 21
8·5
12
8·5 Ø
Cat. No.21EEB344 Closed ring hook
35
13 68
8.5 Ø
22
21
30
53·5
0
8·5 Ø
35 78
8.5 Ø
8·5 Ø
6 Ø 8.5 Ø 22
12
8·5 Ø
78
68
13
95
39
38
7
8·5 Ø
12
53·5
108 130 99·7 125 94·5 108
125
13 130 70
22
8.5 Ø
8.5 Ø
12
8·5 Ø
13
6Ø
39
35
70
388·5 Ø
38
50
35
22
108
125
8·5 Ø 12
Ø
8·5 Ø
12
59
95
38 Ø 8·5 82 77
38
12
13
M5
59
21
21
94·5
99·7
130
M5
82 Cat. No. Cable fixing 82 EEC352 21 duct21 bracket
7Ø
50
8·5 Ø
22
2
59
99·7
38
6Ø
12
12
7Ø
57
82
6Ø 60
21
70
13
7Ø
141
163
7·5 59
M5
30
92
70
77
95
35
13 107
35
12
8·5 Ø
30
M5
94·5
99·7
38
70
M5 Cat. No. EEA328 Luminaire 45 mm edge suspension fixing bracket
82
35
21
82
50
94·5
77
M5
8.5 Ø
8·5 Ø
38
Cat. No. EEA312 Suspended trunking13 8·5 Ø fixing bracket cable duct stirrup
22
12
50
M5
70
70
82
8·5 Ø 57
35
12
108
7Ø
12
125
141
8·5 Ø
70 70
7Ø
M5
21
13
7·5
8·5 Ø
13 82 13
59
92
163
108 60
125
130
38
30
12
15 7Ø
77
82 8·5 Ø
99·7
7·5
21
77
35
8·5 Ø 107
38
82
12
Cat. No. EEA324 Luminaire suspended fixing bracket 50 50
21
130 95
7Ø
21 8·5 Ø
94·5 95
82
38
141
0
82
8·5 Ø trunking
163
Cat. No. EEA308 fixing bracket 57
12
108
21
82 38 Suspended
125
7Ø 130
7Ø
6Ø
78
96
6Ø 30
30
136
All dimensions (mm) are nominal
71
ElectrakÂŽ buscom trunking installation n Design and installation Electrak Buscom trunking system comprises continuous lengths of galvanised steel trunking available in 2 m and 3 m lengths with integral connectors and regular tap-off outlets Each trunking run commences with a feed unit for electrical and comms bus cable termination. The connection between the trunking, the feed unit and subsequent trunking lengths is push fit and requires no tools to terminate the connection or ensure good earthing. Each complete track End stop run is finished with an end stop all trunking parts push together The system fit is supplied with IP 4X ingress protection, fully factory tested and ASTA approved to BS EN 61439-6 : 2011 and is designed to meet the requirements of BS EN 61534-22 : 2014 1 To install - push fit parts together. End stop 2Push To take apart - use a screwdriver to depress the locking catch. fit connection 1 2 1 To install - push fit parts together
2
To take apart - use a screwdriver to depress the locking catch
2
1
1
2 Left feed unit Busbar trunking lengths
1
2
Left feed unit
2
2
1
Buscom trunking lengths
2
1
1
2Push in
to release
1
Push in to release
Considerations before installation Calculate the distance between fixing brackets - the maximum fixing distance should not exceed 4 m. If loads are to be hung, please consult loading charts on page 69. The maximum buscom trunking weight is 2 kg/m When fixing brackets to drop rods or surfaces, see mounting details below Suspended trunking fixing brackets
Cable duct clips into bracket Cable duct clips into bracket EEA312 When using cable duct EEA312 alongusing trunking When cable duct along trunking
EEA308
EEC352 Cable duct bracket EEC352 Cable duct bracket
EEB344
2
1 EEA304
All dimensions (mm) are nominal
72
57mm Edge Surface Fixing Bracket
Luminaire mounting fixing brackets : suspended trunking
EEA324 Luminaire fixing brackets
EEA328 45 mm Edge luminaire fixing brackets (maximum load 5 kg)
All dimensions (mm) are nominal
73
CONTACT DETAILS Quotations and Technical Support: Legrand Electric Ltd. Great King Street North, Birmingham, B19 2LF Tel: +44 (0) 370 608 9020 Fax: +44 (0) 345 600 6760 E-mail: powersales.uk@legrand.co.uk Customer Services: Legrand Electric Ltd. No. 1 Industrial Estate Medmonsley Road, Consett County Durham, DH8 6SR Tel: +44 (0) 345 605 4333 Fax: +44 (0) 345 600 6366 E-mail: powersales.uk@legrand.co.uk Republic of Ireland: Tel: 01 295 9673 Fax: 01 295 4671 E-mail: powersales.uk@legrand.co.uk
FOLLOW US AT www.legrand.co.uk www.legrand.ie www.youtube.com/legrandtvuk www.voltimum.co.uk www.voltimum.ie www.twitter.com/legranduk
Head office (UK and Ireland): Legrand Electric Limited Great King Street North, Birmingham, B19 2LF Tel: +44 (0) 370 608 9000 Fax: +44 (0) 370 608 9004 Website: www.legrand.co.uk
In accordance with its policy of continuous improvement, the Company reserves the right to change specifications and designs without notice. All illustrations, descriptions, dimensions and weights in this catalogue are for guidance and cannot be held binding on the Company. All contents and design presentation included in this publication are Š Legrand Electric Limited. All rights reserved. 2019
This document is printed on sustainably sourced paper. Please recycle.
The Legrand logo is a registered trademark of the Legrand group of companies.
999552 Electrak powering the workplace 01.2019.5k
www.linkedin.com/ company/legranduk