GENERAL CATALOG VER.18.1
Awex brand has been existing in the emergency lighting sector since 2002, invariably fulfilling its clearly defined mission: top-quality state-of-the-art products and customer satisfaction. We offer the full range of emergency lighting devices in compliance with all the European standards. Within 15 years of our market presence, we gained the leading position in the industry thanks to the involvement of knowledge, means, cooperation with best specialists, including research facilities, and investments in innovative projects. Awex means the latest technologies, experienced team of designers and engineers, top quality, reliable equipment, diversity of offer, unique design, unlimited productivity and unblemished reputation supported by references. The biggest award is satisfied and trusted customers. We also enjoy the recognition of independent experts. We were awarded the title of the “Export Leader 2006” for our business volume, and the Puls Biznesu awarded us twice with the “Business Gazelles” prize as one of the most dynamically developing companies in Poland. PROFESSIONAL PERSONNEL We employ the best specialists in many different fields for whom we ensure constant improvement in qualifications by specialist trainings. The company’s design department provides flexible design of individual orders and the team of highly qualified engineers ensures continuous technological progress of offered equipment. The use of modern information flow methods within the company ensures that the offer and functionality of products is updated on an ongoing basis. The effcient project management allows building permanent and trust-based relationships with customers. INVESTMENTS We use the latest world technologies to guarantee quality, precise workmanship, optimised technological process, and work ergonomics. We invest time and means so that every stage of manufacturing our products contributes to meeting any expectations of our customers.
TESTS The research and development works ensure that our offer is constantly updated according to development trends in the industry, and thus we can supply the most modern, multifunctional and technologically advanced products. WE TAKE CARE OF THE ENVIRONMENT We offer the environment-friendly products and the manufacturing process meets strict EU standards. QUALITY WARRANTY Due to the purpose of the company’s mission realization, we have initiated the Quality Control System according to the EN ISO 9001:2008, and the received TÜV NORD certificate guarantees the highest projects quality as well as the production, assemble and service of the emergency lighting devices. In 2016 the company Awex received, for the new products in scope of the fittings and systems of the emergency lighting, a prestige and recognized all over the world the BSI certificate. The certificate’s receipt is related to a long procedure and very restricted tests which we had to do. It proves the highest technical quality of the offered products.
TABLE OF CONTENTS EMERGENCY ESCAPE LIGHTING
5
QUADRO
88
EXIT S
6
91
EXIT M
8
SPECIAL APPLICATION LUMINAIRES
EXIT L ARROW N
10 12
IKLED
92
ARROW P
14
ESCAPELITE
94
LOVATO II
16
ESCAPELITE L
95
LOVATO P
18
FLAGLIGHT
96
AXN
20
WALL LINE
97
AXP
22
EYE LED round
24
EYE LED square
26
MICRO SPOT SPY II
28 30
HELIOS LED
32
HELIOS
34
JOBLED
36
TIGER
37
TIGER LED
38
OUTDOOR LED
40
SK-8
42
INFINITY II
44
EDGE R
46
EDGE S
48
EMERGENCY EXIT SIGNS
51
ARROW N
52
ARROW P
EMERGENCY CONVERSION KITS 99 NEXT & NEXT AUTOTEST
100
UNILED GU10
101
UNILED BM
102
UNILED UM
104
EML
106
SYSTEMS
109
RUBIC MINI UNA
110
RUBIC UNA RUBIC UNA WIRELESS
111 112
DYNAMIC ESCAPE SYSTEM DES FIRE ALARM SYSTEM FAS
114 116
CENTRAL BATTERY SYSTEM FZLV
118
CENTRAL BATTERY SYSTEM SPS
120
CENTRAL BATTERY SYSTEM LPS
122
54
CENTRAL BATTERY SYSTEM CBS
124
EXIT S
56
THE SMART VISIO PLATFORM
126
EXIT M
58
EXIT L
60
INFINITY II AW
62
INFINITY II AC & INFINITY II AL INFINITY II B
ADDITIONAL COMPONENTS
129
64
HTR 25 - HEATER WITH THERMOSTAT
130
66
FOR LOW TEMPERATURE
SK-8
68
BATTERIES
TWINS
70
ACCESSORIES
132
PLEXI LED
72
PICTOGRAMS
134
ESCAPE LED
74
HELIOS & HELIOS LED
76
HELIOS DS & HELIOS DS LED
78
TIGER & TIGER LED
80
TIGER DS & TIGER DS LED SCREEN SCREEN DS
82 84 86
INFORMATION FOR READERS PHOTOMETRY USED SYMBOLS
131
137 138 164
emergency escape lighting EXIT S
6
OUTDOOR LED
40
EXIT M
8
SK-8
42
EXIT L ARROW N
10 12
INFINITY II
44
EDGE R
46
ARROW P
14
EDGE S
48
LOVATO II
16
LOVATO P
18
AXN
20
AXP
22
EYE LED round
24
EYE LED square
26
MICRO SPOT SPY II
28 30
HELIOS LED
32
HELIOS
34
JOBLED
36
TIGER
37
TIGER LED
38
EXIT S
EXIT M
EXIT L
ARROW N
ARROW P
LOVATO II
LOVATO P
AXN
AXP
EYE LED round
EYE LED square
MICRO SPOT
SPY II
HELIOS LED
HELIOS
JOB LED
TIGER LED
TIGER
OUTDOOR LED
SK-8
INFINITY II
EDGE R
EDGE S
Emergency escape lighting EXIT S
226
6
42
RECESSING CUT (mm): • wall • ceiling
220-240V AC 50-60Hz
176-275V DC
LiFePO4
Ni-Cd
KM 61835 BS-EN
Current list of products with Kitemark and ENEC is available at www.awex.eu
105
125
DIMENSIONS (mm):
25
MATERIALS: White, grey or black polycarbonate body Transparent polycarbonate cover MOUNTING: Surface (wall, ceiling) Optionally recessed** (wall, ceiling) Optionally pendant*** (ceiling) POWER SUPPLY: Self contained – 220÷240VAC/50÷60Hz Central battery –220÷240VAC/50÷60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W, 3W LED CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP65 AMBIENT TEMPERATURE: ta: 0°C ÷ 40°C ta: -25°C ÷ 40°C – together with heater for low temperatures OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button AT – autotest RU – Rubic UNA central monitoring RW – RUBIC UNA Wireless central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charging Deep discharge protection Optional adaptation of the fixture for low temperatures up to -25°C III class of insulation of FZLV version **requires an accessory for recessed mounting, RW option not available ***requires an accessory for pendant mounting
24V DC
LED
IP65
Emergency escape lighting SELF-CONTAINED CONFIGURATION CODE
POWER
OUTPUT IN EMERGENCY MODE
MODULE AUTONOMY [h]
MODE
OPTIONS
COLOR
POWER
OUTPUT [lm] ETS
BASIC ETS ETSR ETSU
1W
E
1
1W
C
1
2W
C
1
ETS ETSR ETSU
1W
125
3
SA
PT X
WH GR BL
1W
125
125
135
3
SA
PT X
WH GR BL
2W
235
235
270 150
STANDARD
PREMIUM
1W
B
1
3
SA
AT RU RW WH GR BL
1W
130
130
2W
B
1
3
SA
AT RU RW WH GR BL
2W
265
265
300
3W
B
1
3
SA
AT RU RW WH GR BL
3W
360
360
425
OUTPUT IN EMERGENCY MODE COLOR
POWER
X
WH GR BL
CBS
X
CBS
X
POWER
MODULE
SYSTEM
OPTIONS
1W
F
CB
CBS
2W
F
CB
3W
F
CB
ETS ETSR ETSU
ETSR
ETSU
1W
130
130
150
WH GR BL
2W
265
265
300
WH GR BL
3W
360
360
425
OUTPUT IN EMERGENCY MODE
POWER
MODULE
SYSTEM
OPTIONS
1W
Z
CB
ADE ADP WH GR BL
2W
Z
CB
3W
Z
CB
ETS ETSR ETSU
POWER
POWER
OUTPUT [lm] ETSR
ETSU
1W
130
130
150
ADE ADP WH GR BL
2W
265
265
300
ADE ADP WH GR BL
3W
360
360
425
OUTPUT IN EMERGENCY MODE SYSTEM
COLOR
POWER
OUTPUT [lm] ETSR
ETSU
1W
FZLV
WH GR BL
1W
130
130
150
2W
FZLV
WH GR BL
2W
265
265
300
3W
FZLV
WH GR BL
3W
360
360
425
LEGEND: ETS – fitting EXIT S E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SE – non-maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring system RW – RUBIC UNA Wireless central monitoring CB – central battery version CBS – central battery for circuit monitoring ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC WH – white color GR – grey color BL – black color
7
COLOR
ETS
FZLV SYSTEM CONFIGURATION CODE
OUTPUT [lm] ETS
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE
135
WH GR BL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE
125
PT X
PREMIUM ETS ETSR ETSU
ETSU
SE
3
STANDARD ETS ETSR ETSU
ETSR BASIC
ETS
Emergency escape lighting EXIT M
143
DIMENSIONS (mm):
44
MATERIALS: White, grey or black polycarbonate body Transparent polycarbonate cover MOUNTING: Surface (wall, ceiling) Optionally recessed** (wall, ceiling) Optionally pendant*** (ceiling) POWER SUPPLY: Self contained – 220÷240VAC/50÷60Hz Central battery –220÷240VAC/50÷60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W, 3W LED CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP65 AMBIENT TEMPERATURE: ta: 0°C ÷ 40°C ta: -25°C ÷ 40°C – together with heater for low temperatures OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button AT – autotest RU – Rubic UNA central monitoring RW – RUBIC UNA Wireless central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charging Deep discharge protection Optional adaptation of the fixture for low temperatures up to -25°C III class of insulation of FZLV version **requires an accessory for recessed mounting, RW option not available ***requires an accessory for pendant mounting
276
RECESSING CUT (mm): • wall • ceiling
220-240V AC 50-60Hz
176-275V DC
LiFePO4
Ni-Cd
KM 61835 BS-EN
Current list of products with Kitemark and ENEC is available at www.awex.eu
8
44
24V DC
LED
IP65
Emergency escape lighting SELF-CONTAINED CONFIGURATION CODE
POWER
MODULE
OUTPUT IN EMERGENCY MODE AUTONOMY [h]
MODE
OPTIONS
COLOR
POWER
BASIC ETE
SE
PT X
WH GR BL
1W
3
SA
PT X
WH GR BL
1W
130
1
3
SA
PT X
WH GR BL
2W
250
1
3
SA
PT X
WH GR BL
3W
1W
E
1
1W
C
1
2W
C
3W
C
3
STANDARD ETE
130 STANDARD
PREMIUM ETE
ETE
1W
B
1
3
SA
AT RU RW WH GR BL
1W
135
2W
B
1
3
SA
AT RU RW WH GR BL
2W
270
3W
B
1
3
SA
AT RU RW WH GR BL
3W
350
OUTPUT IN EMERGENCY MODE COLOR
POWER
OUTPUT [lm]
X
WH GR BL
1W
130
CBS
X
WH GR BL
2W
270
CBS
X
WH GR BL
3W
350
POWER
MODULE
SYSTEM
OPTIONS
1W
F
CB
CBS
2W
F
CB
3W
F
CB
OUTPUT IN EMERGENCY MODE
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE
ETE
POWER
MODULE
SYSTEM
OPTIONS
POWER
OUTPUT [lm]
1W
Z
CB
ADE ADP WH GR BL
1W
130
2W
Z
CB
ADE ADP WH GR BL
2W
270
3W
Z
CB
ADE ADP WH GR BL
3W
350
ETE
POWER
SYSTEM
COLOR
POWER
OUTPUT [lm]
1W
FZLV
WH GR BL
1W
130
2W
FZLV
WH GR BL
2W
270
3W
FZLV
WH GR BL
3W
350
LEGEND: ETE – fitting EXIT M E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SE – non-maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring system RW – RUBIC UNA Wireless central monitoring CB – central battery version CBS – central battery for circuit monitoring ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC WH – white color GR – grey color BL – black color
9
COLOR
OUTPUT IN EMERGENCY MODE
FZLV SYSTEM CONFIGURATION CODE
320 PREMIUM
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE
OUTPUT [lm] BASIC
Emergency escape lighting EXIT L
178
DIMENSIONS (mm):
52
MATERIALS: White, grey or black polycarbonate body Transparent polycarbonate cover MOUNTING: Surface (wall, ceiling) Optionally recessed** (wall, ceiling) Optionally pendant*** (ceiling) POWER SUPPLY: Self contained – 220÷240VAC/50÷60Hz Central battery –220÷240VAC/50÷60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W, 3W, 6W LED CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP65 AMBIENT TEMPERATURE: ta: 0°C ÷ 40°C ta: -25°C ÷ 40°C – together with heater for low temperatures OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button AT – autotest RU – Rubic UNA central monitoring RW – RUBIC UNA Wireless central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charging Deep discharge protection Optional adaptation of the fixture for low temperatures up to -25°C III class of insulation of FZLV version **requires an accessory for recessed mounting, RW option not available ***requires an accessory for pendant mounting
332
RECESSING CUT (mm): • wall • ceiling
220-240V AC 50-60Hz
176-275V DC
LiFePO4
Ni-Cd
KM 61835 BS-EN
Current list of products with Kitemark and ENEC is available at www.awex.eu
10
52
24V DC
LED
IP65
Emergency escape lighting SELF-CONTAINED CONFIGURATION CODE
POWER
MODULE
OUTPUT IN EMERGENCY MODE AUTONOMY [h]
MODE
OPTIONS
COLOR
POWER
BASIC ETL
1W
E
1
1W
C
1
2W
C
3W
C
3
SE
PT X
WH GR BL
1W
3
SA
PT X
WH GR BL
1W
125
1
3
SA
PT X
WH GR BL
2W
255
1
3
SA
PT X
WH GR BL
3W
STANDARD ETL
125 STANDARD
PREMIUM
ETL
ETL
1W
B
1
3
SA
AT RU RW WH GR BL
1W
140
2W
B
1
3
SA
AT RU RW WH GR BL
2W
280
3W
B
1
3
SA
AT RU RW WH GR BL
3W
425
6W
B
1
3
SE
AT RU RW WH GR BL
6W
850
OUTPUT IN EMERGENCY MODE COLOR
POWER
OUTPUT [lm]
X
WH GR BL
1W
140
CBS
X
WH GR BL
2W
280
CB
CBS
X
WH GR BL
3W
425
CB
CBS
X
WH GR BL
6W
850
POWER
MODULE
SYSTEM
OPTIONS
1W
F
CB
CBS
2W
F
CB
3W
F
6W
F
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE
ETL
OUTPUT IN EMERGENCY MODE
POWER
MODULE
SYSTEM
OPTIONS
POWER
OUTPUT [lm]
1W
Z
CB
ADE ADP WH GR BL
1W
140
2W
Z
CB
ADE ADP WH GR BL
2W
280
3W
Z
CB
ADE ADP WH GR BL
3W
425
6W
Z
CB
ADE ADP WH GR BL
6W
850
FZLV SYSTEM CONFIGURATION CODE
ETL
COLOR
OUTPUT IN EMERGENCY MODE
POWER
SYSTEM
COLOR
POWER
OUTPUT [lm]
1W
FZLV
WH GR BL
1W
140
2W
FZLV
WH GR BL
2W
280
3W
FZLV
WH GR BL
3W
425
LEGEND: ETL – fitting EXIT L E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SE – non-maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring system RW – RUBIC UNA Wireless central monitoring CB – central battery version CBS – central battery for circuit monitoring ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC WH – white color GR – grey color BL – black color
11
380 PREMIUM
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE
OUTPUT [lm] BASIC
Emergency escape lighting ARROW N
Current list of products with Kitemark and ENEC is available at www.awex.eu
12
DIMENSIONS (mm):
43
76
MATERIALS: White, grey or black polycarbonate body Transparent polycarbonate cover MOUNTING: Surface (wall, ceiling) POWER SUPPLY: Self contained – 220 - 240VAC/50 - 60Hz Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W LED 3x1W power LED S – without optics O – open area C – escape route CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP40 AMBIENT TEMPERATURE: ta: 0°C - +40°C OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) AT – autotest PT – manual test button RU – Rubic UNA central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection III class of insulation of FZLV version
299
220-240V AC 50-60Hz
176-275V DC
24V DC
LED
IP40
Ni-Cd
KM 61835 BS-EN
LiFePO4
Emergency escape lighting SELF-CONTAINED CONFIGURATION CODE
POWER
OUTPUT IN EMERGENCY MODE
MODULE
AUTONOMY [h]
MODE
OPTIONS
COLOR
POWER
OUTPUT [lm] ARNS
ARNS
1W
E
1
3
SE
PT X
WH GR BL
1W
ARNO ARNC
ARNO ARNC
ARNS ARNO ARNC
ARNS ARNO ARNC
1
3
SA
PT X
WH GR BL
1W
110
X
C
1
3
SA
PT X
WH GR BL
2W
200
X
X
3x1W
C
1
3
SA
PT X
WH GR BL
3x1W
X
250
250
1W
B
1
3
SA
AT RU
WH GR BL
1W
120
X
X
2W
B
1
3
SA
AT RU
WH GR BL
2W
220
X
X
3x1W
B
1
3
SA
AT RU
WH GR BL
3x1W
X
270
270
PREMIUM
OUTPUT IN EMERGENCY MODE COLOR
POWER
X
WH GR BL
CBS
X
CBS
X
POWER
MODULE
SYSTEM
OPTIONS
1W
F
CB
CBS
2W
F
CB
3x1W
F
CB
ARNS ARNO ARNC
ARNO
ARNC
1W
120
X
X
WH GR BL
2W
220
X
X
WH GR BL
3x1W
X
270
270
POWER
MODULE
SYSTEM
OPTIONS
COLOR
1W
Z
CB
ADE ADP WH GR BL
2W
Z
CB
3x1W
Z
CB
POWER
OUTPUT [lm] ARNS
ARNO
ARNC
1W
120
X
X
ADE ADP WH GR BL
2W
220
X
X
ADE ADP WH GR BL
3x1W
X
270
270
OUTPUT IN EMERGENCY MODE
POWER
SYSTEM
COLOR
POWER
1W
FZLV
WH GR BL
2W
FZLV
3x1W
FZLV
OUTPUT [lm] ARNS
ARNO
ARNC
1W
120
X
X
WH GR BL
2W
220
X
X
WH GR BL
3x1W
X
270
270
LEGEND: ARNS – fixture ARROW N without optics ARNO – fixture ARROW N with optics for open area ARNC – fixture ARROW N with optics for escape route E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SE – non-maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring system CB – central battery version CBS – central battery for circuit monitoring ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC WH – white color GR – grey color BL – black color
13
OUTPUT [lm] ARNS
OUTPUT IN EMERGENCY MODE
FZLV SYSTEM CONFIGURATION CODE
X
C
2W
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE
X
1W
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE
X STANDARD
PREMIUM ARNS
ARNC
110
STANDARD ARNS
ARNO BASIC
BASIC
Emergency escape lighting ARROW P
DIMENSIONS (mm):
76
MATERIALS: White, grey or black polycarbonate body Transparent polycarbonate cover MOUNTING: Recessed (ceiling) POWER SUPPLY: Self contained – 220 - 240VAC/50 - 60Hz Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W LED 3x1W power LED S – without optics O – open area C – escape route CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP40 AMBIENT TEMPERATURE: ta: 0°C - +40°C OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) AT – autotest PT – manual test button RU – Rubic UNA central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection III class of insulation of FZLV version
328
RECESSING CUT (mm): • ceiling
300 x 45
220-240V AC 50-60Hz
176-275V DC
KM 61835 BS-EN
Current list of products with Kitemark and ENEC is available at www.awex.eu
14
62
24V DC
LED
IP40
Ni-Cd
LiFePO4
Emergency escape lighting SELF-CONTAINED CONFIGURATION CODE
POWER
OUTPUT IN EMERGENCY MODE
MODULE
AUTONOMY [h]
MODE
OPTIONS
COLOR
POWER
OUTPUT [lm] ARPS
ARPS
1W
E
1
3
SE
PT X
WH GR BL
1W
ARPO ARPC
ARPO ARPC
ARPS ARPO ARPC
ARPS ARPO ARPC
1
3
SA
PT X
WH GR BL
1W
110
X
C
1
3
SA
PT X
WH GR BL
2W
200
X
X
3x1W
C
1
3
SA
PT X
WH GR BL
3x1W
X
250
250
1W
B
1
3
SA
AT RU
WH GR BL
1W
120
X
X
2W
B
1
3
SA
AT RU
WH GR BL
2W
220
X
X
3x1W
B
1
3
SA
AT RU
WH GR BL
3x1W
X
270
270
PREMIUM
OUTPUT IN EMERGENCY MODE COLOR
POWER
X
WH GR BL
CBS
X
CBS
X
POWER
MODULE
SYSTEM
OPTIONS
1W
F
CB
CBS
2W
F
CB
3x1W
F
CB
ARPS ARPO ARPC
ARPO
ARPC
1W
120
X
X
WH GR BL
2W
220
X
X
WH GR BL
3x1W
X
270
270
POWER
MODULE
SYSTEM
OPTIONS
COLOR
1W
Z
CB
ADE ADP WH GR BL
2W
Z
CB
3x1W
Z
CB
POWER
OUTPUT [lm] ARPS
ARPO
ARPC
1W
120
X
X
ADE ADP WH GR BL
2W
220
X
X
ADE ADP WH GR BL
3x1W
X
270
270
OUTPUT IN EMERGENCY MODE
POWER
SYSTEM
COLOR
POWER
1W
FZLV
WH GR BL
2W
FZLV
3x1W
FZLV
270
OUTPUT [lm]
ARPS
ARPO
ARPC
1W
120
X
X
WH GR BL
2W
220
X
X
WH GR BL
3x1W
X
270
270
LEGEND: ARPS – fixture ARROW P without optics ARPO – fixture ARROW P with optics for open area ARPC – fixture ARROW P with optics for escape route E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SE – non-maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring system CB – central battery version CBS – central battery for circuit monitoring ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC WH – white color GR – grey color BL – black color
15
OUTPUT [lm] ARPS
OUTPUT IN EMERGENCY MODE
FZLV SYSTEM CONFIGURATION CODE
X
C
2W
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE
X
1W
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE
X STANDARD
PREMIUM ARPS
ARPC
110
STANDARD ARPS
ARPO BASIC
BASIC
Emergency escape lighting LOVATO II
DIMENSIONS (mm):
132
MATERIALS: White, grey or black polycarbonate body MOUNTING: Surface (ceiling) POWER SUPPLY: Self contained – 220 - 240VAC/50 - 60Hz Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W, 3W power LED Optics C - corridor R - escape route O - open area U - universal A - asymmetric CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP41 AMBIENT TEMPERATURE: ta: 0°C - +40°C OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) AT – autotest PT – manual test button RU – Rubic UNA central monitoring RW – RUBIC UNA Wireless central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection III class of insulation of FZLV version
54
132
132
74
132
220-240V AC 50-60Hz
176-275V DC
KM 61835 BS-EN
16
24V DC
LED
IP41
Ni-Cd
LiFePO4
Emergency escape lighting SELF-CONTAINED CONFIGURATION: CODE
OUTPUT IN EMERGENCY MODE
POWER
MODULE
AUTONOMY [h]
MODE
OPTIONS
COLOR
POWER
OUTPUT [lm] LV2R
1W
E
1
3
SE
PT X
WH GR BL
1W
140
130
LV2R LV2U LV2O LV2C LV2A LB2R LB2U LB2O LB2C LB2A
SA
PT X
WH GR BL
1W
140
130
130
140
130
2W
C
1
3
SA
PT X
WH GR BL
2W
240
240
240
240
250
C
1
3
SA
PT X
WH GR BL
3W
340
350
350
330
345
PREMIUM
1W
B
1
3
SA
AT RU RW
WH GR BL
1W
140
140
140
150
140
2W
B
1
3
SA
AT RU RW
WH GR BL
2W
250
270
270
240
270
3W
B
1
3
SA
AT RU RW
WH GR BL
3W
370
390
390
360
370
LV2A
OUTPUT IN EMERGENCY MODE
POWER
MODULE
SYSTEM
OPTIONS
1W
F
CB
CBS
2W
F
CB
3W
F
CB
COLOR
POWER
X
WH GR BL
CBS
X
CBS
X
LV2R LV2U LV2O LV2C LV2A LB2R LB2U LB2O LB2C LB2A
OUTPUT [lm] LV2R
LV2U
LV2O
LV2C
1W
140
140
140
150
140
WH GR BL
2W
250
270
270
240
270
WH GR BL
3W
370
390
390
360
370
LV2A
OUTPUT IN EMERGENCY MODE
POWER
MODULE
SYSTEM
OPTIONS
1W
Z
CB
ADE ADP WH GR BL
2W
Z
CB
3W
Z
CB
FZLV SYSTEM CONFIGURATION: CODE
130
3
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE: CODE
140
1
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
LV2R LV2U LV2O LV2C LV2A LB2R LB2U LB2O LB2C LB2A
130
C
PREMIUM
CODE
LV2A
1W 3W
LV2R LV2U LV2O LV2C LV2A LB2R LB2U LB2O LB2C LB2A
LV2C
STANDARD
STANDARD LV2R LV2U LV2O LV2C LV2A LB2R LB2U LB2O LB2C LB2A
LV2O
BASIC
BASIC LV2R LV2U LV2O LV2C LV2A LB2R LB2U LB2O LB2C LB2A
LV2U
COLOR
POWER
OUTPUT [lm] LV2R
LV2U
LV2O
LV2C
1W
140
140
140
150
140
ADE ADP WH GR BL
2W
250
270
270
240
270
ADE ADP WH GR BL
3W
370
390
390
360
370
LV2A
OUTPUT IN EMERGENCY MODE POWER
SYSTEM
COLOR
POWER
1W
FZLV
WH GR BL
2W
FZLV
WH GR BL
3W
FZLV
WH GR BL
OUTPUT [lm] LV2R
LV2U
LV2O
LV2C
1W
140
140
140
150
140
2W
250
270
270
240
270
3W
370
390
390
360
370
Output in emergency mode of LB2 is the same like LV2.
LEGEND: LV2R – fixture Lovato II with optics for escape route LV2U – fixture Lovato II with universal optics LV2O – fixture Lovato II with optics for open area LV2C – fixture Lovato II with optics for corridor LV2A – fixture Lovato II with asymmetric optics LB2R – fixture Lovato II with large Box and optics for escape route LB2U – fixture Lovato II with large Box and universal optics LB2O – fixture Lovato II with large Box and optics for open area LB2C – fixture Lovato II with large Box and optics for corridor LB2A – fixture Lovato II with large Box and asymmetric optics E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SE – non maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – Rubic UNA central monitoring RW – RUBIC UNA Wireless central monitoring FZLV – central battery FZLV 24 VDC CB – central battery version CBS – central battery for circuit monitoring ADP – central battery with ADP address module – SMART technology ADE – central battery with ADE address module WH – white color GR – grey color BL – black color
17
Emergency escape lighting LOVATO P
95
DIMENSIONS (mm):
95
47,7
32
95
195
8
44
MATERIALS: White, grey or black polycarbonate body MOUNTING: Recessed (ceiling) POWER SUPPLY: Self contained – 220 - 240VAC/50 - 60Hz Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W, 3W power LED Optics C - corridor R - escape route O - open area U - universal A - asymmetric CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP20 AMBIENT TEMPERATURE: ta: 0°C - +40°C OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) AT – autotest PT – manual test button RU – Rubic UNA central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection III class of insulation of FZLV version Electronic gear and battery package installed in a separate box
403
RECESSING CUT (mm): • ceiling
Ø 83mm
h min. 150 mm
220-240V AC 50-60Hz
176-275V DC
KM 61835 BS-EN
Current list of products with Kitemark and ENEC is available at www.awex.eu
18
24V DC
LED
IP20
Ni-Cd
LiFePO4
Emergency escape lighting SELF-CONTAINED CONFIGURATION: CODE
OUTPUT IN EMERGENCY MODE
POWER
MODULE
AUTONOMY [h]
MODE
OPTIONS
COLOR
POWER
OUTPUT [lm] LVPR
1W
E
1
3
SE
PT X
WH GR BL
1W
140
130
LVPR LVPU LVPO LVPC LVPA
SA
PT X
WH GR BL
1W
140
130
130
140
130
2W
C
1
3
SA
PT X
WH GR BL
2W
240
240
240
240
250
C
1
3
SA
PT X
WH GR BL
3W
340
350
350
330
345
PREMIUM
1W
B
1
3
SA
AT RU
WH GR BL
1W
140
140
140
150
140
2W
B
1
3
SA
AT RU
WH GR BL
2W
250
270
270
240
270
3W
B
1
3
SA
AT RU
WH GR BL
3W
370
390
390
360
370
LVPA
OUTPUT IN EMERGENCY MODE
POWER
MODULE
SYSTEM
OPTIONS
1W
F
CB
CBS
2W
F
CB
3W
F
CB
COLOR
POWER
X
WH GR BL
CBS
X
CBS
X
LVPR LVPU LVPO LVPC LVPA
LVPU
LVPO
LVPC
1W
140
140
140
150
140
WH GR BL
2W
250
270
270
240
270
WH GR BL
3W
370
390
390
360
370
LVPA
POWER
MODULE
SYSTEM
OPTIONS
1W
Z
CB
ADE ADP WH GR BL
2W
Z
CB
3W
Z
CB
COLOR
POWER
OUTPUT [lm] LVPR
LVPU
LVPO
LVPC
1W
140
140
140
150
140
ADE ADP WH GR BL
2W
250
270
270
240
270
ADE ADP WH GR BL
3W
370
390
390
360
370
LVPA
OUTPUT IN EMERGENCY MODE POWER
SYSTEM
COLOR
POWER
1W
FZLV
WH GR BL
2W
FZLV
3W
FZLV
OUTPUT [lm] LVPR
LVPU
LVPO
LVPC
1W
140
140
140
150
140
WH GR BL
2W
250
270
390270
240
270
WH GR BL
3W
370
390
390
360
370
LEGEND: LVPR – fixture Lovato P with optics for escape route LVPU – fixture Lovato P with universal optics LVPO – fixture Lovato P with optics for open area LVPC – fixture Lovato P with optics for corridor LVPA – fixture Lovato P with asymmetric optics E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SE – non maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – Rubic UNA central monitoring FZLV – central battery FZLV 24 VDC CB – central battery version CBS – central battery for circuit monitoring ADP – central battery with ADP address module – SMART technology ADE – central battery with ADE address module WH – white color GR – grey color BL – black color
19
OUTPUT [lm] LVPR
OUTPUT IN EMERGENCY MODE
FZLV SYSTEM CONFIGURATION: CODE
130
3
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE: CODE
140
1
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
LVPR LVPU LVPO LVPC LVPA
130
C
PREMIUM
CODE
LVPA
1W 3W
LVPR LVPU LVPO LVPC LVPA
LVPC
STANDARD
STANDARD LVPR LVPU LVPO LVPC LVPA
LVPO
BASIC
BASIC LVPR LVPU LVPO LVPC LVPA
LVPU
Emergency escape lighting AXN
DIMENSIONS (mm):
202
MATERIALS: White, grey or black polycarbonate body MOUNTING: Surface (wall, ceiling) POWER SUPPLY: Self contained – 220 - 240VAC/50 - 60Hz Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W, 3W, 6W power LED Optics C - corridor R - escape route O - open area U - universal A - asymmetric CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP42 or IP65 AMBIENT TEMPERATURE: ta: 0°C - +40°C ta: -25°C ÷ 40°C – together with heater for low temperatures OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) AT – autotest PT – manual test button RU – Rubic UNA central monitoring RW – RUBIC UNA Wireless central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection Optional adaptation of the fixture for low temperatures up to -25°C III class of insulation of FZLV version
220-240V AC 50-60Hz
176-275V DC
20
24V DC
LED
IP65
IP42
Ni-Cd
LiFePO4
KM 61835 BS-EN
Current list of products with Kitemark and ENEC is available at www.awex.eu
58
202
Emergency escape lighting SELF-CONTAINED CONFIGURATION CODE
POWER
OUTPUT IN EMERGENCY MODE MODULE
AUTONOMY [h]
MODE
OPTIONS
COLOR
POWER
OUTPUT [lm] AXNR
AXNU
BASIC AXNR AXNU AXNO AXNC AXNA
1W
E
1W
C
2W 3W
1
AXNA
135
140
130
SE
PT X
WH GR
BL
1W
140
1
3
SA
PT X
WH GR
BL
1W
140
140
135
140
130
C
1
3
SA
PT X
WH GR
BL
2W
240
250
235
240
240
C
1
3
SA
PT X
WH GR
BL
3W
350
360
325
330
345
140 STANDARD
PREMIUM
AXNR AXNU AXNO AXNC AXNA
AXNC
3
STANDARD AXNR AXNU AXNO AXNC AXNA
AXNO
BASIC
PREMIUM
1W
B
1
3
SA
AT RU RW WH GR
BL
1W
150
150
145
150
140
2W
B
1
3
SA
AT RU RW WH GR
BL
2W
260
270
250
260
260
3W
B
1
3
SA
AT RU RW WH GR
BL
3W
370
390
350
360
380
6W*
B
1
3
SA
AT RU RW WH GR
BL
6W
600
620
590
600
580
* power in emergency mode
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE
AXNR AXNU AXNO AXNC AXNA
POWER
OUTPUT IN EMERGENCY MODE
MODULE
SYSTEM
OPTIONS
COLOR
POWER
1W
F
CB
CBS
X
WH GR
BL
2W
F
CB
CBS
X
WH GR
3W
F
CB
CBS
X
6W
F
CB
CBS
X
AXNU
AXNO
AXNC
AXNA
1W
150
150
145
150
140
BL
2W
260
270
250
260
260
WH GR
BL
3W
370
390
350
360
380
WH GR
BL
6W
600
620
590
600
580
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE
AXNR AXNU AXNO AXNC AXNA
POWER
OUTPUT IN EMERGENCY MODE OPTIONS
AXNR AXNU AXNO AXNC AXNA
SYSTEM
1W
Z
CB
ADE ADP WH GR
BL
2W
Z
CB
ADE ADP WH GR
3W
Z
CB
6W
Z
CB
POWER
COLOR
OUTPUT [lm] AXNR
AXNU
AXNO
AXNC
AXNA
1W
150
150
145
150
140
BL
2W
260
270
250
260
260
ADE ADP WH GR
BL
3W
370
390
350
360
380
ADE ADP WH GR
BL
6W
600
620
590
600
580
OUTPUT IN EMERGENCY MODE SYSTEM
COLOR
POWER
OUTPUT [lm] AXNO
AXNC
AXNA
1W
FZLV
WH GR
BL
1W
150
150
145
150
140
2W
FZLV
WH GR
BL
2W
260
270
250
260
260
3W
FZLV
WH GR
BL
3W
370
390
350
360
380
Code of IP42 version are indicated in the legend
LEGEND: AXNR – fixture AXN IP65 with optics for escape route AXNU – fixture AXN IP65 with universal optics AXNO – fixture AXN IP65 with optics for open area AXNC – fixture AXN IP65 with optics for corridor AXNA – fixture AXN IP65 with asymmetric optics optics AXENR – fixture AXN IP42 with optics for escape route AXENU – fixture AXN IP42 with universal optics AXENO – fixture AXN IP42 with optics for open area AXENC – fixture AXN IP42 with optics for corridor AXENA – fixture AXN IP42 with asymmetric optics optics E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings
21
POWER
MODULE
FZLV SYSTEM CONFIGURATION CODE
OUTPUT [lm] AXNR
AXNR
AXNU
Output in emergency mode of AXN IP42 is the same like AXN IP65.
SE – non maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – Rubic UNA central monitoring RW – RUBIC UNA Wireless central monitoring FZLV – central battery FZLV 24 VDC CB – central battery version CBS – central battery for circuit monitoring ADP – central battery with ADP address module – SMART technology ADE – central battery with ADE address module
Emergency escape lighting AXP
100
DIMENSIONS (mm):
37
32
100
195
8
44
MATERIALS: White, grey or black polycarbonate body MOUNTING: Recessed (ceiling) POWER SUPPLY: Self contained – 220 - 240VAC/50 - 60Hz Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W, 3W, 6W power LED Optics C - corridor R - escape route O - open area U - universal A - asymmetric CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP20 or IP65/20 AMBIENT TEMPERATURE: ta: 0°C - +40°C OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) AT – autotest PT – manual test button RU – Rubic UNA central monitoring FZLV – central battery FZLV 24V CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection III class of insulation of FZLV version Electronic gear and battery package installed in a separate box
403
Ø 83mm
RECESSING CUT (mm): • ceiling
h min. 150 mm
220-240V AC 50-60Hz
176-275V DC
KM 61835 BS-EN
Current list of products with Kitemark and ENEC is available at www.awex.eu
22
24V DC
LED
IP20
IP65/20
Ni-Cd
LiFePO4
Emergency escape lighting SELF-CONTAINED CONFIGURATION CODE
POWER
OUTPUT IN EMERGENCY MODE MODULE
AUTONOMY [h]
MODE
OPTIONS
COLOR
POWER
OUTPUT [lm] AXPR
AXPU
BASIC AXPR AXPU AXPO AXPC AXPA
1W
E
1W
C
2W 3W
1
AXPA
135
145
130
SE
PT X
WH GR
BL
1W
140
1
3
SA
PT X
WH GR
BL
1W
140
140
140
135
145
130
C
1
3
SA
PT X
WH GR
BL
2W
240
250
240
240
240
C
1
3
SA
PT X
WH GR
BL
3W
340
360
345
340
345
STANDARD
PREMIUM
PREMIUM
AXPR AXPU AXPO AXPC AXPA
AXPC
3
STANDARD AXPR AXPU AXPO AXPC AXPA
AXPO
BASIC
1W
B
1
3
SA
AT RU
WH GR
BL
1W
150
150
145
160
140
2W
B
1
3
SA
AT RU
WH GR
BL
2W
260
270
260
260
260
3W
B
1
3
SA
AT RU
WH GR
BL
3W
370
390
375
370
380
6W*
B
1
3
SA
AT RU
WH GR
BL
6W
600
620
615
600
580
* power in emergency mode
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE
AXPR AXPU AXPO AXPC AXPA
POWER
OUTPUT IN EMERGENCY MODE
MODULE
SYSTEM
OPTIONS
COLOR
POWER
1W
F
CB
CBS
X
WH GR
BL
2W
F
CB
CBS
X
WH GR
3W
F
CB
CBS
X
6W
F
CB
CBS
X
AXPU
AXPO
AXPC
AXPA
1W
150
150
145
160
140
BL
2W
260
270
260
260
260
WH GR
BL
3W
370
390
375
370
380
WH GR
BL
6W
600
620
615
600
580
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE
AXPR AXPU AXPO AXPC AXPA
POWER
OUTPUT IN EMERGENCY MODE OPTIONS
AXPR AXPU AXPO AXPC AXPA
SYSTEM
1W
Z
CB
ADE ADP WH GR
BL
2W
Z
CB
ADE ADP WH GR
3W
Z
CB
6W
Z
CB
POWER
COLOR
OUTPUT [lm] AXPR
AXPU
AXPO
AXPC
AXPA
1W
150
150
145
160
140
BL
2W
260
270
260
260
260
ADE ADP WH GR
BL
3W
370
390
375
370
380
ADE ADP WH GR
BL
6W
600
620
615
600
580
OUTPUT IN EMERGENCY MODE SYSTEM
COLOR
POWER
OUTPUT [lm] AXPO
AXPC
AXPA
1W
FZLV
WH GR
BL
1W
150
150
145
160
140
2W
FZLV
WH GR
BL
2W
260
270
260
260
260
3W
FZLV
WH GR
BL
3W
370
390
375
370
380
Code of IP20 version are indicated in the legend
LEGEND: AXPR – fixture AXP IP65/20 with optics for escape route AXPU – fixture AXP IP65/20 with universal optics AXPO – fixture AXP IP65/20 with optics for open area AXPC – fixture AXP IP65/20 with optics for corridor AXPA – fixture AXP IP65/20 with asymmetric optics optics AXEPR – fixture AXP IP20 with optics for escape route AXEPU – fixture AXP IP20 with universal optics AXEPO – fixture AXP IP20 with optics for open area AXEPC – fixture AXP IP20 with optics for corridor AXEPA – fixture AXP IP20 with asymmetric optics optics E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings
23
POWER
MODULE
FZLV SYSTEM CONFIGURATION CODE
OUTPUT [lm] AXPR
AXPR
AXPU
Output in emergency mode of AXP IP20 is the same like AXP IP65/20.
SE – non maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – Rubic UNA central monitoring FZLV – central battery FZLV 24 VDC CB – central battery version CBS – central battery for circuit monitoring ADP – central battery with ADP address module – SMART technology ADE – central battery with ADE address module
Emergency escape lighting EYE LED round
47
DIMENSIONS (mm):
80
32
80
195
8
44
MATERIALS: Body made of stainless steel or steel painted white, other colors optionally MOUNTING: Recessed (ceiling) POWER SUPPLY: Self contained – 220 - 240VAC/50 - 60Hz Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W, 3W, 3x1W power LED Optics C - corridor R - escape route O - open area U – universal CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP20 AMBIENT TEMPERATURE: ta: 0°C - +40°C OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) AT – autotest PT – manual test button RU - Rubic UNA central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection III class of insulation of FZLV version Electronic gear and battery package installed in a separate box
403
Ø 63mm
RECESSING CUT (mm): • ceiling
h min. 150 mm
220-240V AC 50-60Hz
176-275V DC
KM 61835 BS-EN
Current list of products with Kitemark and ENEC is available at www.awex.eu
24
24V DC
LED
IP20
Ni-Cd
LiFePO4
Emergency escape lighting SELF-CONTAINED CONFIGURATION CODE
POWER
OUTPUT IN EMERGENCY MODE
MODULE
AUTONOMY [h]
MODE
OPTIONS
COLOR
POWER
OUTPUT [lm] EYR
EYU
BASIC EYR EYU EYO EYC
EYO EYC EY
EYO EYC EY
EYR EYU EYO EYC EY
EYR EYU EYO EYC EY
EYR EYU EYO EYC EY
WH
1W
110
1
3
SA
PT
X
ST
WH
1W
120
140
125
130
–
C
1
3
SA
PT
X
ST
WH
2W
240
240
240
240
–
3W
C
1
3
SA
PT
X
ST
WH
3W
320
360
320
325
–
3x1W
C
1
3
SA
PT
X
ST
WH
3x1W
–
–
–
–
330
1W
B
1
3
SA
AT
RU
ST
WH
1W
140
150
135
140
–
2W
B
1
3
SA
AT
RU
ST
WH
2W
260
270
260
260
–
3W
B
1
3
SA
AT
RU
ST
WH
3W
350
390
350
355
–
3x1W
B
1
3
SA
AT
RU
ST
WH
3x1W
–
–
–
–
360
1W
C
2W
130 STANDARD
PREMIUM
POWER
MODULE
SYSTEM
1W
F
2W
OUTPUT IN EMERGENCY MODE OPTIONS
COLOR
CB
CBS
X
ST
WH
F
CB
CBS
X
ST
3W
F
CB
CBS
X
3x1W
F
CB
CBS
X
POWER
OUTPUT [lm] EYR
EYU
EYO
EYC
EY
1W
140
150
135
140
–
WH
2W
260
270
260
260
–
ST
WH
3W
350
390
350
355
–
ST
WH
3x1W
–
–
–
–
360
OUTPUT IN EMERGENCY MODE
POWER
MODULE
SYSTEM
OPTIONS
COLOR
1W
Z
CB
ADE ADP
ST
WH
2W
Z
CB
ADE ADP
ST
3W
Z
CB
ADE ADP
3x1W
Z
CB
ADE ADP
POWER
OUTPUT [lm] EYR
EYU
EYO
EYC
EY
1W
140
150
135
140
–
WH
2W
260
270
260
260
–
ST
WH
3W
350
390
350
355
–
ST
WH
3x1W
–
–
–
–
360
OUTPUT IN EMERGENCY MODE
POWER
SYSTEM
COLOR
1W
FZLV
ST
WH
2W
FZLV
ST
3W
FZLV
3x1W
FZLV
POWER
OUTPUT [lm] EYR
EYU
EYO
EYC
EY
1W
140
150
135
140
–
WH
2W
260
270
260
260
–
ST
WH
3W
350
390
350
355
–
ST
WH
3x1W
–
–
–
–
360
LEGEND: EYR – fixture EYE LED round with optics for escape route EYU – fixture EYE LED round with universal optics EYO – fixture EYE LED round with optics for open area EYC – fixture EYE LED round with optics for corridor EY – fixture EYE LED round without optics E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SE – non maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – Rubic UNA central monitoring FZLV – central battery FZLV 24 VDC CB – central battery version CBS – central battery for circuit monitoring ADP – central battery with ADP address module – SMART technology ADE – central battery with ADE address module ST – stainless steel WH – fixture in white color
25
–
ST
FZLV SYSTEM CONFIGURATION CODE
130
X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE
125
PT
1
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE
EY
SE
E
PREMIUM EYR EYU
EYC
3
1W
STANDARD EYR EYU
EYO
BASIC
Emergency escape lighting EYE LED square
47
DIMENSIONS (mm):
80
32
80
195
8
44
MATERIALS: Body made of stainless steel or steel painted white, other colors optionally MOUNTING: Recessed (ceiling) POWER SUPPLY: Self contained – 220 - 240VAC/50 - 60Hz Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W, 3W, 3x1W power LED Optics C - corridor R - escape route O - open area U – universal CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP20 AMBIENT TEMPERATURE: ta: 0°C - +40°C OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) AT – autotest PT – manual test button RU – Rubic UNA central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection Electronic gear and battery package installed in a separate box III class of insulation of FZLV version
403
Ø 63mm
RECESSING CUT (mm): • ceiling
h min. 150 mm
220-240V AC 50-60Hz
176-275V DC
KM 61835 BS-EN
Current list of products with Kitemark and ENEC is available at www.awex.eu
26
24V DC
LED
IP20
Ni-Cd
LiFePO4
Emergency escape lighting SELF-CONTAINED CONFIGURATION CODE
POWER
OUTPUT IN EMERGENCY MODE
MODULE
AUTONOMY [h]
MODE
OPTIONS
COLOR
POWER
OUTPUT [lm] EYKR
EYKU
BASIC EYKR EYKU EYKO EYKC
EYKO EYKC EYK
EYKO EYKC EYK
EYKR EYKU EYKO EYKC EYK
EYKR EYKU EYKO EYKC EYK
EYKR EYKU EYKO EYKC EYK
WH
1W
110
1
3
SA
PT
X
ST
WH
1W
120
140
125
130
–
C
1
3
SA
PT
X
ST
WH
2W
240
240
240
240
–
3W
C
1
3
SA
PT
X
ST
WH
3W
320
360
320
325
–
3x1W
C
1
3
SA
PT
X
ST
WH
3x1W
–
–
–
–
330
1W
B
1
3
SA
AT
RU
ST
WH
1W
140
150
135
140
–
2W
B
1
3
SA
AT
RU
ST
WH
2W
260
270
260
260
–
3W
B
1
3
SA
AT
RU
ST
WH
3W
350
390
350
355
–
3x1W
B
1
3
SA
AT
RU
ST
WH
3x1W
–
–
–
–
360
1W
C
2W
130 STANDARD
PREMIUM
POWER
MODULE
SYSTEM
1W
F
2W
OUTPUT IN EMERGENCY MODE OPTIONS
COLOR
CB
CBS
X
ST
WH
F
CB
CBS
X
ST
3W
F
CB
CBS
X
3x1W
F
CB
CBS
X
POWER
OUTPUT [lm] EYKR
EYKU
EYKO
EYKC
EYK
1W
140
150
135
140
–
WH
2W
260
270
260
260
–
ST
WH
3W
350
390
350
355
–
ST
WH
3x1W
–
–
–
–
360
OUTPUT IN EMERGENCY MODE
POWER
MODULE
SYSTEM
OPTIONS
COLOR
1W
Z
CB
ADE ADP
ST
WH
2W
Z
CB
ADE ADP
ST
3W
Z
CB
ADE ADP
3x1W
Z
CB
ADE ADP
POWER
OUTPUT [lm] EYKR
EYKU
EYKO
EYKC
EYK
1W
140
150
135
140
–
WH
2W
260
270
260
260
–
ST
WH
3W
350
390
350
355
–
ST
WH
3x1W
–
–
–
–
360
OUTPUT IN EMERGENCY MODE
POWER
SYSTEM
COLOR
1W
FZLV
ST
WH
2W
FZLV
ST
3W
FZLV
3x1W
FZLV
POWER
OUTPUT [lm] EYKR
EYKU
EYKO
EYKC
EYK
1W
140
150
135
140
–
WH
2W
260
270
260
260
–
ST
WH
3W
350
390
350
355
–
ST
WH
3x1W
–
–
–
–
360
LEGEND: EYKR – fixture EYE LED square with optics for escape route EYKU – fixture EYE LED square with universal optics EYKO – fixture EYE LED square with optics for open area EYKC – fixture EYE LED square with optics for corridor EYK – fixture EYE LED square without optics E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SE – non maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – Rubic UNA central monitoring FZLV – central battery FZLV 24 VDC CB – central battery version CBS – central battery for circuit monitoring ADP – central battery with ADP address module – SMART technology ADE – central battery with ADE address module ST – stainless steel WH – fixture in white color
27
–
ST
FZLV SYSTEM CONFIGURATION CODE
130
X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE
125
PT
1
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE
EYK
SE
E
PREMIUM EYKR EYKU
EYKC
3
1W
STANDARD EYKR EYKU
EYKO
BASIC
Emergency escape lighting MICRO SPOT
DIMENSIONS (mm):
32
MATERIALS: White polycarbonate body MOUNTING: Recessed (ceiling) POWER SUPPLY: Self contained – 220÷240VAC/50÷60Hz Central battery –220÷240VAC/50÷60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W, 3W LED Optics: U - universal R - escape route CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP20 AMBIENT TEMPERATURE: ta : 0°C ÷ 40°C OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button RU – Rubic UNA central monitoring FZLV – central battery FZLV 24V CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charging Deep discharge protection III class of insulation of FZLV version Electronic gear and battery package installed in a separate box
8
403
220-240V AC 50-60Hz
28
176-275V DC
24V DC
LED
IP20
LIFEPO4
Ni-Cd
Emergency escape lighting SELF-CONTAINED CONFIGURATION CODE
POWER
OUTPUT IN EMERGENCY MODE
MODULE
AUTONOMY [h]
MODE
OPTIONS
BASIC MSU
MSR
1W
E
MSR
1
3
SE
PT
X
1W
MSR
MSU
MSR
MSU
MSR
C
1
3
SA
PT
X
1W
125
120
C
1
3
SA
PT
X
2W
240
230
3W
C
1
3
SA
PT
X
3W
340
325
PREMIUM
1W
B
1
3
SA
AT
RU
1W
140
130
2W
B
1
3
SA
AT
RU
2W
265
250
3W
B
1
3
SA
AT
RU
3W
380
360
OUTPUT IN EMERGENCY MODE OPTIONS
MSU
MSR
MODULE
SYSTEM
1W
F
CB
CBS
X
1W
140
130
2W
F
CB
CBS
X
2W
265
250
3W
F
CB
CBS
X
3W
380
360
MSU
MSR
OUTPUT IN EMERGENCY MODE OUTPUT [lm]
POWER
MODULE
SYSTEM
OPTIONS
POWER
1W
Z
CB
ADE ADP
1W
140
130
2W
Z
CB
ADE ADP
2W
265
250
3W
Z
CB
ADE ADP
3W
380
360
MSU
MSR
OUTPUT IN EMERGENCY MODE OUTPUT [lm]
POWER
SYSTEM
POWER
1W
FZLV
1W
140
130
2W
FZLV
2W
265
250
3W
FZLV
3W
380
360
LEGEND: MSU – fixture MICRO SPOT with universal optic MSR – fixture MICRO SPOT with optics for escape route E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SE – non-maintained SA – maintained (with an option of connecting as non-maintained) X – fitting without additional options PT – manual test button AT – autotest RU – RUBIC UNA central monitoring CB – central battery version CBS – central battery for circuit monitoring ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC
29
POWER
OUTPUT [lm]
POWER
FZLV SYSTEM CONFIGURATION CODE
120
2W
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE
125
1W
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE
MSR
STANDARD
PREMIUM MSU
MSU BASIC
STANDARD MSU
OUTPUT [lm]
POWER
MSU
MSR
Emergency escape lighting SPY II
DIMENSIONS (mm):
44 44
22
22
50 - 82
38
MATERIALS: White or grey polycarbonate body MOUNTING: Inside light fitting POWER SUPPLY: Self contained – 220÷240VAC/50÷60Hz Central battery –220÷240VAC/50÷60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W, 3W LED CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP20 AMBIENT TEMPERATURE: ta : 0°C ÷ 40°C OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button AT – autotest RU – Rubic UNA central monitoring FZLV – central battery FZLV 24V CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charging Deep discharge protection III class of insulation of FZLV version Electronic gear and battery package installed in a separate box
134
220-240V AC 50-60Hz
176-275V DC
24V DC
LED
IP20
LiFePO4
30
Ni-Cd
Emergency escape lighting SELF-CONTAINED CONFIGURATION:
OUTPUT IN EMERGENCY MODE
CODE
POWER
MODULE
SP2
1W
E
AUTONOMY [h]
MODE
OPTIONS
COLOR
POWER
PT
GR WH
1W
BASIC
BASIC
1
3
SE
X
STANDARD SP2
140 STANDARD
1W
C
1
3
SA
PT
X
GR WH
1W
140
2W
C
1
3
SA
PT
X
GR WH
2W
250
3W
C
1
3
SE
PT
X
GR WH
3W
PREMIUM SP2
OUTPUT [lm]
360 PREMIUM
1W
B
1
3
SA
AT
RU
GR WH
1W
150
2W
B
1
3
SA
AT
RU
GR WH
2W
270
3W
B
1
3
SE
AT
RU
GR WH
3W
390
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE MODULE
SYSTEM
OUTPUT IN EMERGENCY MODE
CODE
POWER
OPTIONS
COLOR
1W
F
CB
CBS
X
GR WH
1W
150
SP2
2W
F
CB
CBS
X
GR WH
2W
270
3W*
F
CB
CBS
X
GR WH
3W
390
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE: CODE
POWER
SP2
3W*
SP2
MODULE
SYSTEM
OPTIONS
COLOR
1W
Z
CB
ADE ADP
GR WH
1W
150
2W
Z
CB
ADE ADP
GR WH
2W
270
Z
CB
ADE ADP
GR WH
3W
390
POWER
OUTPUT [lm]
OUTPUT IN EMERGENCY MODE
POWER
SYSTEM
COLOR
1W
FZLV
GR WH
1W
150
2W
FZLV
GR WH
2W
270
3W*
FZLV
GR WH
3W
390
*only non maintained
LEGEND: SP2 – fixture SPY II E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SE – non-maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring CB – central battery version CBS – central battery for circuit monitoring ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC WH – fixture in white color GR – fixture in grey color
31
OUTPUT [lm]
OUTPUT IN EMERGENCY MODE
FZLV SYSTEM CONFIGURATION: CODE
POWER
POWER
OUTPUT [lm]
Emergency escape lighting HELIOS LED
DIMENSIONS (mm):
136
MATERIALS: White polycarbonate body Transparent or opal polycarbonate cover MOUNTING: Surface (wall, ceiling) POWER SUPPLY: Self contained – 220÷240VAC/50÷60Hz Central battery – 220÷240VAC/50÷60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W, 3W, 3x1W, 6x1W power LED CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP42 or IP65 AMBIENT TEMPERATURE: ta: 0°C ÷ 40°C ta: -25°C ÷ 40°C – together with heater for low temperatures OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button AT – autotest RU – Rubic UNA central monitoring RW – RUBIC UNA Wireless central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charging Deep discharge protection Optional adaptation of the fixture for low temperatures up to -25°C Protection against mechanical impacts – IK08 III class of insulation of FZLV version
220-240V AC 50-60Hz
176-275V DC
32
24V DC
LED
IP42
IP65
LiFePO4
Ni-Cd
KM 61835 BS-EN
Current list of products with Kitemark and ENEC is available at www.awex.eu
79
356
Emergency escape lighting SELF-CONTAINED CONFIGURATION CODE
POWER
OUTPUT IN EMERGENCY MODE
MODULE
AUTONOMY [h]
MODE
OPTIONS
COVER
POWER
BASIC
BASIC HWM HWEM
1W
E
1W
C
2W
*OUTPUT [lm]
1
3
SE
PT
X
TR OP
1W
1
3
SA
PT
X
TR OP
1W
120
C
1
3
SA
PT
X
TR OP
2W
220
3W
C
1
3
SA
PT
X
TR OP
3W
330
HWD HWED
3x1W
C
1
3
SA
PT
X
TR
3x1W
340
HHP
6x1W*
B
1
3
SA
PT
X
TR
6x1W
STANDARD
STANDARD HWM HWEM
120
920 PREMIUM
PREMIUM 1W
B
1
3
SA
AT RU RW
TR OP
1W
130
2W
B
1
3
SA
AT RU RW
TR OP
2W
240
3W
B
1
3
SA
AT RU RW
TR OP
3W
360
HWD HWED
3x1W
B
1
3
SA
AT RU RW
TR
3x1W
370
HHP
6x1W*
B
1
3
SA
AT RU RW
TR
6x1W
920
HWM HWEM
* power in emergency mode
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE
POWER
MODULE
SYSTEM
OUTPUT IN EMERGENCY MODE OPTIONS
COVER
POWER
*OUTPUT [lm]
1W
F
CB
CBS
X
TR OP
1W
130
HWM HWEM
2W
F
CB
CBS
X
TR OP
2W
240
3W
F
CB
CBS
X
TR OP
3W
360
HWD HWED
3x1W
F
CB
CBS
X
TR
3x1W
370
HHP
6x1W
F
CB
CBS
X
TR
6x1W
920
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE
OUTPUT IN EMERGENCY MODE
POWER
MODULE
SYSTEM
OPTIONS
COVER
POWER
*OUTPUT [lm]
1W
Z
CB
ADE ADP
TR OP
1W
130
HWM HWEM
2W
Z
CB
ADE ADP
TR OP
2W
240
3W
Z
CB
ADE ADP
TR OP
3W
360
HWD HWED
3x1W
Z
CB
ADE ADP
TR
3x1W
370
HHP
6x1W
Z
CB
ADE ADP
TR
6x1W
920
FZLV SYSTEM CONFIGURATION CODE
OUTPUT IN EMERGENCY MODE
POWER
SYSTEM
COVER
POWER
*OUTPUT [lm]
1W
FZLV
TR OP
1W
130
HWM HWEM
2W
FZLV
TR OP
2W
240
3W
FZLV
TR OP
3W
360
HWD HWED
3x1W
FZLV
TR
3x1W
370
HHP
6x1W
FZLV
TR
6x1W
920
*light Output value for transparent cover only
LEGEND: HWM – fixture Helios IP65, assembly altitudes: 2,5 – 10 m HWEM – fixture Helios IP42, assembly altitudes: 2,5 – 10 m HWD – fixture Helios IP65, assembly altitudes: 8 – 14m HWED – fixture Helios IP42, assembly altitudes: 8 – 14m HHP – fixture Helios IP65 6x1W assembly altitudes: 2,5 – 14m E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SE – non-maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options
33
AT – autotest RU – RUBIC UNA central monitoring RW – RUBIC UNA Wireless central monitoring CB – central battery version CBS – central battery for circuit monitoring ADP – central battery with ADP address module – SMART technology ADE – central battery with ADE address module FZLV – central battery FZLV 24 VDC TR – transparent polycarbonate cover OP – opal polycarbonate cover
Emergency escape lighting HELIOS
DIMENSIONS (mm):
136
MATERIALS: White polycarbonate body Transparent polycarbonate cover with Fresnel optics MOUNTING: Surface (wall, ceiling) POWER SUPPLY: Self contained – 220÷240VAC/50÷60Hz Central battery –220÷240VAC/50÷60Hz; 176 - 275VDC LIGHT SOURCE: 8W, 11W, 18W fluorescent lamp CHARGING: Maximum 24h AUTONOMY AND BATTERIES: 1h or 3h , Ni-Cd 3,6V batteries INSULATION CLASS: II IP RATING: IP42 or IP65 AMBIENT TEMPERATURE: ta: 0°C ÷ 40°C ta: -25°C ÷ 40°C – together with heater for low temperatures OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button AT – autotest CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charging Deep discharge protection Optional adaptation of the fixture for low temperatures up to -25°C Protection against mechanical impacts – IK08
220-240V AC 50-60Hz
176-275V DC
34
T5 G5
TC-SEL 2G7
IP42
Ni-Cd
KM 61835 BS-EN
Current list of products with Kitemark and ENEC is available at www.awex.eu
79
356
IP65
Emergency escape lighting SELF-CONTAINED CONFIGURATION CODE
H HE
POWER
MODULE
MODE
OPTIONS
8W
T
AUTONOMY [h] 1
3
SE SA
PT
AT
11W
T
1
3
SE SA
PT
AT
18W
T
1
3
SE
PT
AT
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE
H HE
POWER
MODULE
SYSTEM
8W
T
CB
OPTIONS CBS
X
11W
T
CB
CBS
X
18W
T
CB
CBS
X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE
H HE
POWER
MODULE
SYSTEM
OPTIONS
8W
T
CB
ADL ADS
11W
T
CB
ADL ADS
18W
T
CB
ADL ADS
LEGEND: H – fixture Helios IP 65 HE – fixture Helios IP 42 T – electronic gear for LFL fittings SE – non-maintained SA – maintained PT – manual test button X – fitting without additional options AT – autotest CB – central battery version CBS – central battery for circuit monitoring ADL – central battery with ADL module ADS – central battery with ADS address module – SMART technology
35
Emergency escape lighting JOBLED MATERIALS: Black, hit resistant polycarbonate POWER SUPPLY: 230 VAC/50Hz optionally – 12 VDC LIGHT SOURCE: 3W (120 lm) highpower LED CHARGING: Maximum 24h AUTONOMY AND BATTERIES: 8,5h 6V / 4,0 Ah batteries INSULATION CLASS: II IP RATING: IP43 ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Charging through wall mounted adapter or directly from mains 230V
DIMENSIONS (mm): POWER [W]
MODULE
AUTONOMY [h]
3
Z
8,5
128
112
130
290
CODE JOBLED
132
SELF CONTAINED CONFIGURATION
55
80
230V AC 50-60Hz
36
DC
LED
Ø130
IP43
Emergency escape lighting TIGER MATERIALS: White polycarbonate body Transparent polycarbonate cover MOUNTING: Surface (wall, ceiling) Optional assembly in dry-wall or under plastering POWER SUPPLY: Self contained – 220÷240VAC/50÷60Hz Central battery –220÷240VAC/50÷60Hz; 176 - 275VDC LIGHT SOURCE: 8W fluorescent lamp CHARGING: Maximum 24h AUTONOMY AND BATTERIES: 1h or 3h , Ni-Cd 3,6V batteries INSULATION CLASS: II IP RATING: IP22 AMBIENT TEMPERATURE: ta: 0°C ÷ 40°C OPTIONS: SE – non maintained SA – maintained PT – manual test button AT – autotest CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charging Deep discharge protection
DIMENSIONS (mm):
350
RECESSING CUT (mm): • wall • ceiling
SELF-CONTAINED CONFIGURATION CODE
POWER
MODULE
TG
8W
T
AUTHONOMY [h] 1
3
MODE SE
OPTIONS
SA
PT
325 x 120
AT
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE
POWER
MODULE
SYSTEM
TG
8W
T
CB
OPTIONS CBS
X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE
POWER
MODULE
SYSTEM
OPTIONS
TG
8W
T
CB
ADL ADS
220-240V AC 50-60Hz
176-275V DC
Current list of products with Kitemark and ENEC is available at www.awex.eu
37
IP22
Ni-Cd
KM 61835 BS-EN
LEGEND: TG – fixture Tiger T – electronic gear for LFL fittings SE – non-maintained SA – maintained PT – manual test button X – fitting without additional options AT – autotest CB – central battery version CBS – central battery for circuit monitoring ADL – central battery with ADL module ADS – central battery with ADS address module – SMART technology
T5 G5
144
118
323
Emergency escape lighting TIGER LED
38
DIMENSIONS (mm):
350
RECESSING CUT (mm): • wall • ceiling
325 x 120
220-240V AC 50-60Hz
176-275V DC
Ni-Cd
LiFePO4
24V DC
LED
IP22
144
323
118
MATERIALS: White polycarbonate body Transparent or opal polycarbonate cover MOUNTING: Surface (wall, ceiling) Optional assembly in dry-wall or under plastering POWER SUPPLY: Self contained – 220÷240VAC/50÷60Hz Central battery –220÷240VAC/50÷60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W, 3W LED CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP22 AMBIENT TEMPERATURE: ta: 0°C ÷ 40°C OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button AT – autotest RU – Rubic UNA central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charging Deep discharge protection III class of insulation of FZLV version
Emergency escape lighting SELF-CONTAINED CONFIGURATION CODE
POWER
OUTPUT IN EMERGENCY MODE
MODULE
AUTONOMY [h]
MODE
OPTIONS
COVER
POWER
BASIC TL
1W
E
1
3
SE
PT
X
TR OP
1W
STANDARD TL
120 STANDARD
1W
C
1
3
SA
PT
X
TR OP
1W
120
2W
C
1
3
SA
PT
X
TR OP
2W
230
3W
C
1
3
SA
PT
X
TR OP
3W
PREMIUM TL
TL
1W
B
1
3
SA
AT
RU
TR OP
1W
135
2W
B
1
3
SA
AT
RU
TR OP
2W
250
3W
B
1
3
SA
AT
RU
TR OP
3W
380
OPTIONS
COVER
OUTPUT IN EMERGENCY MODE
POWER
MODULE
SYSTEM
POWER
OUTPUT [lm]
1W
F
CB
CBS
X
TR OP
1W
135
2W
F
CB
CBS
X
TR OP
2W
250
3W
F
CB
CBS
X
TR OP
3W
380
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE
TL
OUTPUT IN EMERGENCY MODE
POWER
MODULE
SYSTEM
OPTIONS
COVER
POWER
OUTPUT [lm]
1W
Z
CB
ADE ADP
TR OP
1W
135
2W
Z
CB
ADE ADP
TR OP
2W
250
3W
Z
CB
ADE ADP
TR OP
3W
380
FZLV SYSTEM CONFIGURATION CODE
TL
OUTPUT IN EMERGENCY MODE
POWER
SYSTEM
COVER
POWER
OUTPUT [lm]
1W
FZLV
TR OP
1W
135
2W
FZLV
TR OP
2W
250
3W
FZLV
TR OP
3W
380
LEGEND: TL – fixture Tiger LED E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SE – non-maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring CB – central battery version CBS – central battery for circuit monitoring ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC TR – transparent polycarbonate cover OP – opal polycarbonate cover
39
340 PREMIUM
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE
OUTPUT [lm] BASIC
Emergency escape lighting OUTDOOR LED
Current list of products with Kitemark and ENEC is available at www.awex.eu
40
DIMENSIONS (mm):
222
77
227
MATERIALS: Stainless steel painted white, grey or black MOUNTING: Surface (wall) POWER SUPPLY: Self contained – 220 - 240VAC/50 - 60Hz Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 3x1W LED CHARGING: STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: I or III IP RATING: IP66 AMBIENT TEMPERATURE: ta: 0°C - +40°C ta: -25°C ÷ 40°C – together with heater for low temperatures OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) AT – autotest PT – manual test button RU – Rubic UNA central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection III class of insulation of FZLV version Optional adaptation of the fixture for low temperatures up to -25°C Protection against mechanical impacts – IK10
220-240V AC 50-60Hz
176-275V DC
24V 24V DC
LED
IP66
Ni-Cd
LiFePO4
Emergency escape lighting SELF-CONTAINED CONFIGURATION CODE
POWER
OUTPUT IN EMERGENCY MODE
MODULE
AUTONOMY [h]
MODE
OPTIONS
COLOR
POWER
STANDARD ODB
3x1W
C
1
3
SA
PT
X
WH GR
BL
3x1W
PREMIUM ODB
3x1W
B
1
330 PREMIUM
3
SA
AT
RU
WH GR
BL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE
POWER
MODULE
SYSTEM
ODB
3x1W
F
CB
3x1W
360
OUTPUT IN EMERGENCY MODE OPTIONS CBS
X
COLOR WH GR
BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
POWER
OUTPUT [lm]
3x1W
360
OUTPUT IN EMERGENCY MODE
CODE
POWER
MODULE
SYSTEM
ODB
3x1W
Z
CB
OPTIONS
COLOR
ADE ADP WH GR
FZLV SYSTEM CONFIGURATION
BL
POWER
OUTPUT [lm]
3x1W
360
OUTPUT IN EMERGENCY MODE
CODE
POWER
SYSTEM
ODB
3x1W
FZLV
COLOR WH GR
BL
LEGEND: ODB – fixture Outdoor LED C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SE – non-maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring CB – central battery version CBS – central battery for circuit monitoring ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC WH – fixture in white color GR – fixture in grey color BL – fixture in black color
41
OUTPUT [lm]
STANDARD
POWER
OUTPUT [lm]
3x1W
360
Emergency escape lighting SK-8
DIMENSIONS (mm):
41
250
325
160
MATERIALS: White polycarbonate body Transparent polycarbonate cover with lens MOUNTING: Surface (wall, ceiling) Optional recessed (ceiling**) POWER SUPPLY: Self contained – 220 - 240VAC/50 - 60Hz Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 3W LED CHARGING: STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP44 AMBIENT TEMPERATURE: ta: 0°C - +40°C OPTIONS: SA – maintained (with an option of connecting as non-maintained) AT – autotest PT – manual test button RU – Rubic UNA central monitoring RW – RUBIC UNA Wireless central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection III class of insulation of FZLV version **requires an accessory for recessed mounting, RW option not available
310
20
RECESSING CUT (mm): • ceiling
350 x 60
220-240V AC 50-60Hz
176-275V DC
24V DC
LED
IP44
Ni-Cd
LiFePO4
*see pictogram
*1pc. of universal pictogram is included in each single box Current list of products with Kitemark and ENEC is available at www.awex.eu
42
KM 61835 BS-EN
Emergency escape lighting SELF-CONTAINED CONFIGURATION CODE
POWER
OUTPUT IN EMERGENCY MODE
MODULE
AUTONOMY [h]
MODE
OPTIONS
COLOR
POWER
STANDARD SK-8
3W
C
1
3
SA
PT
X
WT
3W
PREMIUM SK-8
3W
B
1
OUTPUT [lm]
STANDARD 100 PREMIUM 3
SA
AT RU RW
WT
OPTIONS
COLOR
POWER
OUTPUT [lm]
WT
3W
120
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE
POWER
MODULE
SYSTEM
SK-8
3W
F
CB
3W
120
OUTPUT IN EMERGENCY MODE
CBS
X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
OUTPUT IN EMERGENCY MODE
CODE
POWER
MODULE
SYSTEM
OPTIONS
COLOR
POWER
OUTPUT [lm]
SK-8
3W
Z
CB
ADE ADP
WT
3W
120
FZLV SYSTEM CONFIGURATION
OUTPUT IN EMERGENCY MODE
CODE
POWER
SYSTEM
COLOR
POWER
OUTPUT [lm]
SK-8
3W
FZLV
WT
3W
120
LEGEND: SK8 – fixture SK-8 C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring RW – RUBIC UNA Wireless central monitoring CB – central battery version CBS – central battery for circuit monitoring ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC WT – white body and transparent cover
43
Emergency escape lighting INFINITY II
DIMENSIONS (mm):
337
220-240V AC 50-60Hz
176-275V DC
57
24V DC
LED
IP40
Ni-Cd
LiFePO4
KM 61835 BS-EN
*see pictogram
INFINITY II B
INFINITY II AW
*1pc. of universal pictogram is included in each single box Current list of products with Kitemark and ENEC is available at www.awex.eu
44
189
37
72
MATERIALS: White, grey or black polycarbonate body Plexi glass MOUNTING: Surface (wall) Optionally recessed (wall**) POWER SUPPLY: Self contained – 220 - 240VAC/50 - 60Hz Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 3W LED CHARGING: STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP40 AMBIENT TEMPERATURE: ta: 0°C - +40°C OPTIONS: SA – maintained (with an option of connecting as non-maintained) AT – autotest PT – manual test button RU - Rubic UNA central monitoring RW – RUBIC UNA Wireless central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection III class of insulation of FZLV version Fixture with floor illumination system **requires an accessory – concrete box, RW option not available
INFINITY II AC
INFINITY II AL
Emergency escape lighting SELF-CONTAINED CONFIGURATION CODE
OUTPUT IN EMERGENCY MODE POWER
MODULE
AUTONOMY [h]
MODE
OPTIONS
COLOR
POWER
IF2BWD IF2AWD IF2ACD IF2ALD
3W
C
1
3
SA
PT
X
WH
GR
BL
3W
3W
B
1
3
SA
AT RU RW WH
GR
BL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
3W
80
OUTPUT IN EMERGENCY MODE
CODE
POWER
MODULE
SYSTEM
IF2BWD IF2AWD IF2ACD IF2ALD
3W
F
CB
OPTIONS CBS
X
COLOR WH
GR
BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
POWER
OUTPUT [lm]
3W
80
OUTPUT IN EMERGENCY MODE
CODE
POWER
MODULE
SYSTEM
OPTIONS
IF2BWD IF2AWD IF2ACD IF2ALD
3W
Z
CB
ADE ADP
FZLV SYSTEM CONFIGURATION
COLOR WH
GR
BL
POWER
OUTPUT [lm]
3W
80
OUTPUT IN EMERGENCY MODE
CODE
POWER
SYSTEM
IF2BWD IF2AWD IF2ACD IF2ALD
3W
FZLV
COLOR WH
*Output in emergency mode of IF2AWD, IF2ACD, IF2ALD is the same like IF2BWD
LEGEND: IF2BWD – fixture INFINITY II B one side with floor illumination IF2AWD – fixture INFINITY II AW two side with floor illumination IF2ACD – fixture INFINITY II AC two side with floor illumination IF2ALD – fixture INFINITY II AL two side with floor illumination C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring RW – RUBIC UNA Wireless central monitoring CB – central battery version CBS – central battery for circuit monitoring ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24VDC WH – white color GR – grey color BL – black color
45
70 PREMIUM
PREMIUM IF2BWD IF2AWD IF2ACD IF2ALD
OUTPUT [lm]
STANDARD
STANDARD
GR
BL
POWER
OUTPUT [lm]
3W
80
Emergency escape lighting EDGE R MATERIALS: White polycarbonate body Opal polycarbonate cover MOUNTING: Surface (wall, ceiling) Optionally pendant* (ceiling) POWER SUPPLY: Self contained – 220÷240VAC/50÷60Hz Central battery – 220÷240VAC/50÷60Hz; 176 - 275VDC
Current list of products with Kitemark and ENEC is available at www.awex.eu
46
DIMENSIONS (mm):
280
LIGHT SOURCE - MAINS MODE: Power: 12W, 18W, 24W LED Color Temperature: 3000K, 4000K LIGHT SOURCE - EMERGENCY MODE: Power: 1W, 3W LED Color Temperature: 6500K CHARGING: BASIC: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II IP RATING: IP54 AMBIENT TEMPERATURE: ta: 0°C ÷ 40°C OPTIONS: SE – LED emergency section - non maintained SA – LED emergency section - maintained (night mode) AT – autotest PT – manual test button RU – Rubic UNA central monitoring RW – RUBIC UNA Wireless central monitoring CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charging Deep discharge protection Color Temperature in emergency mode: 6500K Optional fixtures with MCR motion sensor *requires an accessory for pendant mounting
63
280
220-240V
176-275V
IP54
50-60Hz
Ni-Cd
Emergency escape lighting MAINS MODE CONFIGURATION DETECTION
CODE EDRE12 EDRE18 EDRE24
MAINS MODE COLOR
WH
WS
3000
4000
WH
WS
3000
4000
WH
WS
3000
4000
OUTPUT [lm]
CODE
TEMPERATURE
EDRE12 EDRE18 EDRE24
SELF-CONTAINED CONFIGURATION POWER*
MODULE
EDRE12 EDRE18 EDRE24
1W
E
AUTONOMY [h]
MODE
OPTION
DETECTION
COLOR TEMPERATURE
POWER*
1
3
WH
WS
2690
3000
4000
1W
B
1
3
SA
105 PREMIUM
AT RU RW
WH
WS
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
3000
4000
3W
315
CENTRAL BATTERY MODE OPTION
DETECTION
COLOR
MODULE
SYSTEM
1W
F
CB
CBS
X
WH
3000
4000
3W
F
CB
CBS
X
WH
3000
4000
EDRE12
12W
X
CB
CBS
X
WH
3000
4000
12W
1325
1425
X
EDRE18
18W
X
CB
CBS
X
WH
3000
4000
18W
2080
2235
X
EDRE24
24W
X
CB
CBS
X
WH
3000
4000
24W
2500
2690
X
TEMPERATURE
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE
POWER*
OUTPUT [lm]
POWER*
EDRE12 EDRE18 EDRE24
3000K
4000K
1W
X
X
6500K 115
3W
X
X
315
CENTRAL BATTERY MODE OUTPUT [lm]
POWER*
MODULE
SYSTEM
OPTION
1W
Z
CB
ADP
WH
WS
3000
4000
3W
Z
CB
ADP
WH
WS
3000
4000
EDRE12
12W
X
CB
ADS
WH
WS
3000
4000
12W
1325
1425
X
EDRE18
18W
X
CB
ADS
WH
WS
3000
4000
18W
2080
2235
X
EDRE24
24W
X
CB
ADS
WH
WS
3000
4000
24W
2500
2690
X
* – power in emergency mode
LEGEND: B – electronic gear for PREMIUM self-contained fittings E – electronic gear for BASIC self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings ADS – central battery with ADS address module – SMART technology ADP – central battery with ADP address module – SMART technology SE – LED emergency section - non maintained SA – LED emergency section - maintained (night mode) X – fitting without additional options AT – autotest PT – manual test button RU – RUBIC UNA central monitoring RW – RUBIC UNA Wireless central monitoring CB – central battery system CBS – central battery for circuit monitoring WH – fitting without motion sensor MCR WS – fitting with motion sensor MCR 3000 – LED color temperature K 4000 – LED color temperature K EDRE12 – fitting EDGE R 12W in maintained mode EDRE18 – fitting EDGE R 18W in maintained mode EDRE24 – fitting EDGE R 24W in maintained mode
DETECTION
COLOR
POWER*
EDRE12 EDRE18 EDRE24
47
2235
2500
BASIC PT X
SE PREMIUM
CODE
1425
2080
OUTPUT [lm]
BASIC
3W
4000K
1325
EMERGENCY MODE
CODE
EDRE12 EDRE18 EDRE24
3000K
TEMPERATURE
3000K
4000K
1W
X
X
6500K 115
3W
X
X
315
Emergency escape lighting EDGE S MATERIALS: White polycarbonate body Opal polycarbonate cover MOUNTING: Surface (wall, ceiling) Optional recessed* (ceiling) Optionally pendant** (ceiling) POWER SUPPLY: Self contained – 220÷240VAC/50÷60Hz Central battery – 220÷240VAC/50÷60Hz; 176 - 275VDC
DIMENSIONS (mm):
280
LIGHT SOURCE - MAINS MODE: Power: 12W, 18W, 24W LED Color Temperature: 3000K, 4000K LIGHT SOURCE - EMERGENCY MODE: Power: 1W, 3W LED Color Temperature: 6500K CHARGING: BASIC: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II IP RATING: IP54 AMBIENT TEMPERATURE: ta: 0°C ÷ 40°C OPTIONS: SE – LED emergency section - non maintained SA – LED emergency section - maintained (night mode) AT – autotest PT – manual test button RU – Rubic UNA central monitoring RW – RUBIC UNA Wireless central monitoring CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charging Deep discharge protection Color Temperature in emergency mode: 6500K Optional fixtures with MCR motion sensor *requires an accessory for recessed mounting, RW option not available **requires an accessory for pendant mounting
63
280
RECESSING CUT (mm): • wall • ceiling
310 x 310
220-240V
176-275V
IP54
50-60Hz
Ni-Cd
Current list of products with Kitemark and ENEC is available at www.awex.eu
48
Emergency escape lighting MAINS MODE CONFIGURATION DETECTION
CODE EDSE12 EDSE18 EDSE24
MAINS MODE COLOR
WH
WS
3000
4000
WH
WS
3000
4000
WH
WS
3000
4000
OUTPUT [lm]
CODE
TEMPERATURE
EDSE12 EDSE18 EDSE24
SELF-CONTAINED CONFIGURATION POWER*
MODULE
EDSE12 EDSE18 EDSE24
1W
E
AUTONOMY [h]
MODE
OPTION
DETECTION
COLOR TEMPERATURE
1
3
WH
WS
2690
3000
4000
1W
B
1
3
SA
SE
105 PREMIUM
AT RU RW
WH
WS
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
3000
4000
3W
315
CENTRAL BATTERY MODE OPTION
DETECTION
COLOR
MODULE
SYSTEM
1W
F
CB
CBS
X
WH
3000
4000
3W
F
CB
CBS
X
WH
3000
4000
EDSE12
12W
X
CB
CBS
X
WH
3000
4000
12W
1325
1425
X
EDSE18
18W
X
CB
CBS
X
WH
3000
4000
18W
2080
2235
X
EDSE24
24W
X
CB
CBS
X
WH
3000
4000
24W
2500
2690
X
TEMPERATURE
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE
POWER*
OUTPUT [lm]
POWER*
EDSE12 EDSE18 EDSE24
3000K
4000K
1W
X
X
6500K 115
3W
X
X
315
CENTRAL BATTERY MODE OUTPUT [lm]
POWER*
MODULE
SYSTEM
OPTION
1W
Z
CB
ADP
WH
WS
3000
4000
3W
Z
CB
ADP
WH
WS
3000
4000
EDSE12
12W
X
CB
ADS
WH
WS
3000
4000
12W
1325
1425
X
EDSE18
18W
X
CB
ADS
WH
WS
3000
4000
18W
2080
2235
X
EDSE24
24W
X
CB
ADS
WH
WS
3000
4000
24W
2500
2690
X
* – power in emergency mode
LEGEND: B – electronic gear for PREMIUM self-contained fittings E – electronic gear for BASIC self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings ADS – central battery with ADS address module – SMART technology ADP – central battery with ADP address module – SMART technology SE – LED emergency section - non maintained SA – LED emergency section - maintained (night mode) AT – autotest PT – manual test button RU – RUBIC UNA central monitoring RW – RUBIC UNA Wireless central monitoring CB – central battery system CBS – central battery for circuit monitoring WH – fitting without motion sensor MCR WS – fitting with motion sensor MCR 3000 – LED color temperature K 4000 – LED color temperature K EDSE12 – fitting EDGE S 12W in maintained mode EDSE18 – fitting EDGE S 18W in maintained mode EDSE24 – fitting EDGE S 24W in maintained mode
DETECTION
COLOR
POWER*
EDSE12 EDSE18 EDSE24
49
2235
2500
BASIC PT X
SE
PREMIUM
CODE
1425
2080
OUTPUT [lm]
POWER*
BASIC
3W
4000K
1325
EMERGENCY MODE
CODE
EDSE12 EDSE18 EDSE24
3000K
TEMPERATURE
3000K
4000K
1W
X
X
6500K 115
3W
X
X
315
emergency exit signS ARROW N
52
ARROW P
54
EXIT S
56
EXIT M
58
EXIT L
60
INFINITY II AW
62
INFINITY II AC & INFINITY II AL
64
INFINITY II B
66
SK-8
68
TWINS
70
PLEXI LED
72
ESCAPE LED
74
HELIOS & HELIOS LED
76
HELIOS DS & HELIOS DS LED
78
TIGER & TIGER LED
80
TIGER DS & TIGER DS LED SCREEN SCREEN DS
82 84 86
QUADRO
88
ARROW N
ARROW P
EXIT S
EXIT M
EXIT L
INFINITY II AW
INFINITY II B
SK-8
TWINS
PLEXI LED
ESCAPE LED
HELIOS & HELIOS LED
TIGER & TIGER LED
TIGER DS & TIGER DS LED
SCREEN
SCREEN DS
QUADRO
INFINITY II AC & INFINITY II AL
HELIOS DS & HELIOS DS LED
emergency exit signs ARROW N
DIMENSIONS (mm):
43
125
206
MATERIALS: White, grey or black polycarbonate body Plexi glass MOUNTING: Surface (wall, ceiling) Optionally mounting on a rope sling (ceiling*) POWER SUPPLY: Self contained – 220 - 240VAC/50 - 60Hz Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W LED CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP40 VIEWING DISTANCE: 25m AMBIENT TEMPERATURE: ta: 0°C - +40°C OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) AT – autotest PT – manual test button RU – Rubic UNA central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection III class of insulation of FZLV version *requires an accessory for mounting on a rope sling
299
220-240V AC 50-60Hz
176-275V DC
52
24V DC
LED
IP40
Ni-Cd
*see pictogram
*1pc. of universal pictogram is included in each single box Current list of products with Kitemark and ENEC is available at www.awex.eu
250
LiFePO4
KM 61835 BS-EN
emergency exit signs SELF-CONTAINED CONFIGURATION CODE
POWER
MODULE
AUTONOMY [h]
MODE
OPTIONS
COLOR
BASIC ARN
1W
E
1
3
SE
PT
X
WH
GR
BL
STANDARD ARN
1W
C
1
3
SA
PT
X
WH
GR
BL
2W
C
1
3
SA
PT
X
WH
GR
BL
1W
B
1
3
SA
AT
RU
WH
GR
BL
2W
B
1
3
SA
AT
RU
WH
GR
BL
PREMIUM ARN
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE ARN
POWER
MODULE
SYSTEM
1W
F
CB
CBS
OPTIONS X
WH
COLOR GR
BL
2W
F
CB
CBS
X
WH
GR
BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE ARN
POWER
MODULE
SYSTEM
OPTIONS
1W
Z
CB
ADE ADP
WH
GR
BL
2W
Z
CB
ADE ADP
WH
GR
BL
FZLV SYSTEM CONFIGURATION CODE ARN
POWER
SYSTEM
1W
FZLV
WH
COLOR GR
BL
2W
FZLV
WH
GR
BL
LEGEND: ARN – fixture ARROW N E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SE – non-maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring CB – central battery version CBS – central battery for circuit monitoring ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC WH – white color GR – grey color BL – black color
53
COLOR
emergency exit signs ARROW P
DIMENSIONS (mm):
62
125
206
MATERIALS: White, grey or black polycarbonate body Plexi glass MOUNTING: Recessed (ceiling) POWER SUPPLY: Self contained – 220 - 240VAC/50 - 60Hz Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W LED CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP40 VIEWING DISTANCE: 25m AMBIENT TEMPERATURE: ta: 0°C - +40°C OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) AT – autotest PT – manual test button RU – Rubic UNA central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection III class of insulation of FZLV version
6
250
328
RECESSING CUT (mm): • ceiling
300 x 45
220-240V AC 50-60Hz
176-275V DC
*see pictogram
*1pc of universal pictogram is included in each single box Current list of products with Kitemark and ENEC is available at www.awex.eu
54
24V DC
LED
IP40
Ni-Cd
LiFePO4
KM 61835 BS-EN
emergency exit signs SELF-CONTAINED CONFIGURATION: CODE
POWER
MODULE
AUTONOMY [h]
MODE
OPTIONS
COLOR
BASIC ARP
1W
E
1
3
SE
PT
X
WH
GR
BL
STANDARD ARP
1W
C
1
3
SA
PT
X
WH
GR
BL
2W
C
1
3
SA
PT
X
WH
GR
BL
PREMIUM ARP
1W
B
1
3
SA
AT
RU
WH
GR
BL
2W
B
1
3
SA
AT
RU
WH
GR
BL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE ARP
POWER
MODULE
SYSTEM
1W
F
CB
CBS
OPTIONS X
WH
COLOR GR
BL
2W
F
CB
CBS
X
WH
GR
BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE: CODE ARP
POWER
MODULE
SYSTEM
OPTIONS
1W
Z
CB
ADE ADP
WH
GR
BL
2W
Z
CB
ADE ADP
WH
GR
BL
FZLV SYSTEM CONFIGURATION: CODE ARP
POWER
SYSTEM
1W
FZLV
WH
COLOR GR
BL
2W
FZLV
WH
GR
BL
LEGEND: ARP – fixture ARROW P E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SE – non-maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring CB – central battery version CBS – central battery for circuit monitoring ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC WH – white color GR – grey color BL – black color
55
COLOR
emergency exit signs EXIT S
DIMENSIONS (mm):
125 226
42
209
107
150
MATERIALS: White, gray or black polycarbonate body Transparent polycarbonate cover Plexi glass MOUNTING: Surface (wall, ceiling**) Optionally recessed*** (wall, ceiling**) Optionally pendant**** (ceiling**) POWER SUPPLY: Self contained – 220÷240VAC/50÷60Hz Central battery –220÷240VAC/50÷60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W, LED CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP65 VIEWING DISTANCE: 20 m AMBIENT TEMPERATURE: ta: 0°C ÷ 40°C ta: -25°C ÷ 40°C – together with heater for low temperatures OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button AT – autotest RU – Rubic UNA central monitoring RW – RUBIC UNA Wireless central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charging Deep discharge protection Optional adaptation of the fixture for low temperatures up to -25°C III class of insulation of FZLV version **additional plexi for two-sided emergency exit signs ***requires an accessory for recessed mounting, RW option not available ****requires an accessory for pendant mounting
RECESSING CUT (mm): • wall • ceiling
220-240V AC 50-60Hz
176-275V DC
LiFePO4
Ni-Cd
24V DC
LED
IP65
d=20m
*see pictogram *1pc of universal pictogram is included in each single box Current list of products with Kitemark and ENEC is available at www.awex.eu
56
KM 61835 BS-EN
emergency exit signs SELF-CONTAINED CONFIGURATION: CODE
POWER
MODULE
AUTONOMY [h]
MODE
OPTIONS
COLOR
BASIC ETS
1W
E
1
3
SE
PT
X
WH
GR
BL
STANDARD ETS
1W
C
1
3
SA
PT
X
WH
GR
BL
2W
C
1
3
SA
PT
X
WH
GR
BL
PREMIUM ETS
1W
B
1
3
SA
AT RU RW
WH
GR
BL
2W
B
1
3
SA
AT RU RW
WH
GR
BL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE
POWER
MODULE
SYSTEM
ETS
1W
F
CB
CBS
OPTIONS X
WH
COLOR GR
BL
ETS
2W
F
CB
CBS
X
WH
GR
BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE
POWER
MODULE
SYSTEM
OPTIONS
ETS
1W
Z
CB
ADE ADP
WH
COLOR GR
BL
ETS
2W
Z
CB
ADE ADP
WH
GR
BL
FZLV SYSTEM CONFIGURATION CODE ETS
POWER
SYSTEM
1W
FZLV
WH
COLOR GR
BL
2W
FZLV
WH
GR
BL
LEGEND: ETS – fitting EXIT S E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SE – non-maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring RW – RUBIC UNA Wireless central monitoring CB – central battery version CBS – central battery for circuit monitoring ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC WH – white color GR – grey color BL – black color
57
emergency exit signs EXIT M
260 276
58
125
175
260
259
RECESSING CUT (mm): • wall • ceiling
220-240V AC 50-60Hz
176-275V DC
LiFePO4
Ni-Cd
*see pictogram *1pc of universal pictogram is included in each single box Current list of products with Kitemark and ENEC is available at www.awex.eu
143
125
DIMENSIONS (mm):
44
MATERIALS: White, gray or black polycarbonate body Transparent polycarbonate cover Plexi glass MOUNTING: Surface (wall, ceiling**) Optionally recessed*** (wall, ceiling**) Optionally pendant**** (ceiling**) POWER SUPPLY: Self contained – 220÷240VAC/50÷60Hz Central battery –220÷240VAC/50÷60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W LED CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP65 VIEWING DISTANCE: 25 m AMBIENT TEMPERATURE: ta: 0°C ÷ 40°C ta: -25°C ÷ 40°C – together with heater for low temperatures OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button AT – autotest RU – Rubic UNA central monitoring RW – RUBIC UNA Wireless central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charging Deep discharge protection Optional adaptation of the fixture for low temperatures up to -25°C III class of insulation of FZLV version **additional plexi for two-sided emergency exit signs ***requires an accessory for recessed mounting, RW option not available ****requires an accessory for pendant mounting
24V DC
LED
IP65
KM 61835 BS-EN
emergency exit signs SELF-CONTAINED CONFIGURATION: CODE
POWER
MODULE
AUTONOMY [h]
MODE
OPTIONS
COLOR
BASIC ETE
1W
E
1
3
SE
PT
X
WH
GR
BL
STANDARD ETE
1W
C
1
3
SA
PT
X
WH
GR
BL
2W
C
1
3
SA
PT
X
WH
GR
BL
PREMIUM ETE
1W
B
1
3
SA
AT RU RW
WH
GR
BL
2W
B
1
3
SA
AT RU RW
WH
GR
BL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE ETE
POWER
MODULE
SYSTEM
1W
F
CB
CBS
OPTIONS X
WH
COLOR GR
BL
2W
F
CB
CBS
X
WH
GR
BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE ETE
POWER
MODULE
SYSTEM
OPTIONS
1W
Z
CB
ADE ADP
WH
COLOR GR
BL
2W
Z
CB
ADE ADP
WH
GR
BL
FZLV SYSTEM CONFIGURATION CODE ETE
POWER
SYSTEM
1W
FZLV
WH
COLOR GR
BL
2W
FZLV
WH
GR
BL
LEGEND: ETE – fitting EXIT M E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SE – non-maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring RW – RUBIC UNA Wireless central monitoring CB – central battery version CBS – central battery for circuit monitoring ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC WH – white color GR – grey color BL – black color
59
emergency exit signs EXIT L
DIMENSIONS (mm):
178 332
52
306
152
207
MATERIALS: White, gray or black polycarbonate body Transparent polycarbonate cover Plexi glass MOUNTING: Surface (wall, ceiling**) Optionally recessed*** (wall, ceiling**) Optionally pendant**** (ceiling**) POWER SUPPLY: Self contained – 220÷240VAC/50÷60Hz Central battery –220÷240VAC/50÷60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W LED CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP65 VIEWING DISTANCE: 30 m AMBIENT TEMPERATURE: ta: 0°C ÷ 40°C ta: -25°C ÷ 40°C – together with heater for low temperatures OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button AT – autotest RU – Rubic UNA central monitoring RW – RUBIC UNA Wireless central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charging Deep discharge protection Optional adaptation of the fixture for low temperatures up to -25°C III class of insulation of FZLV version **additional plexi for two-sided emergency exit signs ***requires an accessory for recessed mounting, RW option not available ****requires an accessory for pendant mounting
RECESSING CUT (mm): • wall • ceiling
220-240V AC 50-60Hz
176-275V DC
LiFePO4
Ni-Cd
24V DC
LED
IP65
d=30m
*see pictogram *1pc of universal pictogram is included in each single box Current list of products with Kitemark and ENEC is available at www.awex.eu
60
KM 61835 BS-EN
emergency exit signs SELF-CONTAINED CONFIGURATION: CODE
POWER
MODULE
AUTONOMY [h]
MODE
OPTIONS
COLOR
BASIC ETL
1W
E
1
3
SE
PT
X
WH
GR
BL
STANDARD ETL
1W
C
1
3
SA
PT
X
WH
GR
BL
2W
C
1
3
SA
PT
X
WH
GR
BL
PREMIUM ETL
1W
B
1
3
SA
AT RU RW
WH
GR
BL
2W
B
1
3
SA
AT RU RW
WH
GR
BL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE ETL
POWER
MODULE
SYSTEM
1W
F
CB
CBS
OPTIONS X
WH
COLOR GR
BL
2W
F
CB
CBS
X
WH
GR
BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE ETL
POWER
MODULE
SYSTEM
OPTIONS
1W
Z
CB
ADE ADP
WH
COLOR GR
BL
2W
Z
CB
ADE ADP
WH
GR
BL
FZLV SYSTEM CONFIGURATION CODE ETL
POWER
SYSTEM
1W
FZLV
WH
COLOR GR
BL
2W
FZLV
WH
GR
BL
LEGEND: ETL – fitting EXIT L E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SE – non-maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring system RW – RUBIC UNA Wireless central monitoring CB – central battery version CBS – central battery for circuit monitoring ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC WH – white color GR – grey color BL – black color
61
emergency exit signs INFINITY II AW
DIMENSIONS (mm):
232
INFINITY II AW
MATERIALS: White, grey or black polycarbonate body Plexi glass MOUNTING: Surface (wall) Optionally recessed (wall**) POWER SUPPLY: Self contained – 220 - 240VAC/50 - 60Hz Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W ,2W LED CHARGING: STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP40 VIEWING DISTANCE: 30m AMBIENT TEMPERATURE: ta: 0°C - + 40°C OPTIONS: SA – maintained (with an option of connecting as non-maintained) AT – autotest PT – manual test button RU – Rubic UNA central monitoring RW – RUBIC UNA Wireless central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection III class of insulation of FZLV version **requires an accessory - concrete box, RW option not available
40
72
337
RECESSING CUT (mm): • wall
260 x 80
220-240V AC 50-60Hz
176-275V DC
24V DC
LED
IP40
Ni-Cd
LiFePO4
d=30m
*see pictogram
*1pc of universal pictogram is included in each single box Current list of products with Kitemark and ENEC is available at www.awex.eu
62
KM 61835 BS-EN
emergency exit signs SELF-CONTAINED CONFIGURATION: CODE
POWER
MODULE
AUTONOMY [h]
MODE
OPTIONS
COLOR
STANDARD IF2AWS
1W
C
1
3
SA
PT
X
WH
GR
BL
2W
C
1
3
SA
PT
X
WH
GR
BL
PREMIUM IF2AWS
1W
B
1
3
SA
AT RU RW
WH
GR
BL
2W
B
1
3
SA
AT RU RW
WH
GR
BL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE IF2AWS
POWER
MODULE
SYSTEM
1W
F
CB
CBS
OPTIONS X
WH
COLOR GR
BL
2W
F
CB
CBS
X
WH
GR
BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE IF2AWS
POWER
MODULE
SYSTEM
OPTIONS
1W
Z
CB
ADE ADP
WH
COLOR GR
BL
2W
Z
CB
ADE ADP
WH
GR
BL
FZLV SYSTEM CONFIGURATION CODE IF2AWS
POWER
SYSTEM
1W
FZLV
WH
COLOR GR
BL
2W
FZLV
WH
GR
BL
LEGEND: IF2AWS – fixture INFINITY II AW C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring RW – RUBIC UNA Wireless central monitoring CB – central battery version CBS – central battery for circuit monitoring ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC WH – white color GR – grey color BL – black color
63
emergency exit signs INFINITY II AC & INFINITY II AL
DIMENSIONS (mm):
72
INFINITY II AC
232
20
max 1m
337
INFINITY II AL
MATERIALS: White, grey or black polycarbonate body Plexi glass MOUNTING: Surface (ceiling, rope sling) Optionally recessed (ceiling**) POWER SUPPLY: Self contained – 220 - 240VAC/50 - 60Hz Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W LED CHARGING: STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP40 VIEWING DISTANCE: 30m AMBIENT TEMPERATURE: ta: 0°C÷40°C OPTIONS: SA – maintained (with an option of connecting as non-maintained) PT – manual test button AT – autotest RU – Rubic UNA central monitoring RW – RUBIC UNA Wireless central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator mains power supply and battery charge Deep discharge protection III class of insulation of FZLV version **requires an accessory for recessed mounting, RW option not available
337
220-240V AC 50-60Hz
176-275V DC
24V DC
LED
IP40
Ni-Cd
LiFePO4 d=30m
*1pc of universal pictogram is included in each single box Current list of products with Kitemark and ENEC is available at www.awex.eu
64
*see pictogram
KM 61835 BS-EN
emergency exit signs SELF-CONTAINED CONFIGURATION: CODE
POWER
MODULE
AUTONOMY [h]
MODE
OPTIONS
COLOR
STANDARD IF2ACS IF2ALS
1W
C
1
3
SA
PT
X
WH
GR
BL
2W
C
1
3
SA
PT
X
WH
GR
BL
PREMIUM IF2ACS IF2ALS
1W
B
1
3
SA
AT RU RW
WH
GR
BL
2W
B
1
3
SA
AT RU RW
WH
GR
BL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE IF2ACS IF2ALS
POWER
MODULE
SYSTEM
1W
F
CB
CBS
OPTIONS X
WH
COLOR GR
BL
2W
F
CB
CBS
X
WH
GR
BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE IF2ACS IF2ALS
POWER
MODULE
SYSTEM
OPTIONS
1W
Z
CB
ADE ADP
WH
GR
BL
2W
Z
CB
ADE ADP
WH
GR
BL
FZLV SYSTEM CONFIGURATION CODE IF2ACS IF2ALS
POWER
SYSTEM
1W
FZLV
WH
COLOR GR
BL
2W
FZLV
WH
GR
BL
LEGEND: IF2ACS – fixture INFINITY II AC IF2ALS – fixture INFINITY II AL C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring RW – RUBIC UNA Wireless central monitoring CB – central battery version CBS – central battery for circuit monitoring ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC WH – white color GR – grey color BL – black color
65
COLOR
emergency exit signs INFINITY II B
DIMENSIONS (mm):
72
189
37
INFINITY II B
MATERIALS: White, grey or black polycarbonate body Plexi glass MOUNTING: Surface (wall) Optionally recessed (wall**) POWER SUPPLY: Self contained – 220 - 240VAC/50 - 60Hz Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W LED CHARGING: STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP40 VIEWING DISTANCE: 30m AMBIENT TEMPERATURE: ta: 0°C - + 40°C OPTIONS: SA – maintained (with an option of connecting as non-maintained) AT – autotest PT – manual test button RU - Rubic UNA central monitoring RW – RUBIC UNA Wireless central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection III class of insulation of FZLV version **requires an accessory - concrete box, RW option not available
337
220-240V AC 50-60Hz
176-275V DC
57
24V DC
LED
IP40
Ni-Cd
LiFePO4
d=30m
*see pictogram
*1pc of universal pictogram is included in each single box Current list of products with Kitemark and ENEC is available at www.awex.eu
66
KM 61835 BS-EN
emergency exit signs SELF-CONTAINED CONFIGURATION: CODE
POWER
MODULE
AUTONOMY [h]
MODE
OPTIONS
COLOR
STANDARD IF2BWS
1W
C
1
3
SA
PT
X
WH
GR
BL
2W
C
1
3
SA
PT
X
WH
GR
BL
PREMIUM IF2BWS
1W
B
1
3
SA
AT RU RW
WH
GR
BL
2W
B
1
3
SA
AT RU RW
WH
GR
BL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE IF2BWS
POWER
MODULE
SYSTEM
1W
F
CB
CBS
OPTIONS X
WH
COLOR GR
BL
2W
F
CB
CBS
X
WH
GR
BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE IF2BWS
POWER
MODULE
SYSTEM
OPTIONS
1W
Z
CB
ADE ADP
WH
GR
BL
2W
Z
CB
ADE ADP
WH
GR
BL
FZLV SYSTEM CONFIGURATION CODE IF2BWS
POWER
SYSTEM
1W
FZLV
WH
COLOR GR
BL
2W
FZLV
WH
GR
BL
LEGEND: IF2BWS – fixture INFINITY II B C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring RW – RUBIC UNA Wireless central monitoring CB – central battery version CBS – central battery for circuit monitoring ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC WH – white color GR – grey color BL – black color
67
COLOR
emergency exit signs SK-8
DIMENSIONS (mm):
41
250
325
160
MATERIALS: White polycarbonate body Opal polycarbonate cover MOUNTING: Surface (ceiling, wall) Optional recessed (ceiling**) POWER SUPPLY: Self contained – 220÷240VAC/50÷60Hz Central battery – 220÷240VAC/50÷60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W LED CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP44 VIEWING DISTANCE: 30m AMBIENT TEMPERATURE: ta: 0°C÷40°C OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button AT – autotest RU – Rubic UNA central monitoring RW – RUBIC UNA Wireless central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection III class of insulation of FZLV version **requires an accessory for recessed mounting, RW option not available
310
20
RECESSING CUT (mm): • ceiling
350 x 60
220-240V AC 50-60Hz
176-275V DC
24V DC
LED
IP44
Ni-Cd
LiFePO4 d=30m
*see pictogram
*1pc of universal pictogram is included in each single box Current list of products with Kitemark and ENEC is available at www.awex.eu
68
KM 61835 BS-EN
emergency exit signs SELF-CONTAINED CONFIGURATION: CODE
POWER
MODULE
AUTONOMY [h]
MODE
OPTIONS
COLOR
BASIC SK8
1W
E
1
3
SE
PT
X
WL
STANDARD SK8
1W
C
1
3
SA
PT
X
WL
2W
C
1
3
SA
PT
X
WL
PREMIUM SK8
1W
B
1
3
SA
AT RU RW
WL
2W
B
1
3
SA
AT RU RW
WL
OPTIONS
COLOR
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE SK8
POWER
MODULE
SYSTEM
1W
F
CB
CBS
X
WL
2W
F
CB
CBS
X
WL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE SK8
POWER
MODULE
SYSTEM
OPTIONS
COLOR
1W
Z
CB
ADE ADP
WL
2W
Z
CB
ADE ADP
WL
FZLV SYSTEM CONFIGURATION CODE SK8
POWER
SYSTEM
COLOR
1W
FZLV
WL
2W
FZLV
WL
LEGEND: SK8 – fixture SK-8 E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SE – non-maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring RW – RUBIC UNA Wireless central monitoring CB – central battery version CBS – central battery for circuit monitoring ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC WL – white body and opal cover
69
emergency exit signs TWINS
DIMENSIONS (mm):
48
243
83
315
160
MATERIALS: Silver or black aluminium body Plexi glass MOUNTING: Surface (wall, ceiling) Optionally mounting on a rope sling (ceiling*) POWER SUPPLY: Self contained – 220 - 240VAC/50 - 60Hz Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W LED CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: I or III IP RATING: IP41 VIEWING DISTANCE: 30m AMBIENT TEMPERATURE: ta: 0°C - +40°C OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) AT – autotest PT – manual test button RU – Rubic UNA central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection III class of insulation of FZLV version *requires an accessory for mounting on a rope sling
220-240V AC 50-60Hz
176-275V DC
24V DC
LED
IP41
Ni-Cd
LiFePO4
d=30m
*see pictogram
*1pc of universal pictogram is included in each single box Current list of products with Kitemark and ENEC is available at www.awex.eu
70
KM 61835 BS-EN
emergency exit signs SELF-CONTAINED CONFIGURATION: CODE
POWER
MODULE
AUTONOMY [h]
MODE
OPTIONS
COLOR
BASIC TW
1W
E
1
3
SE
PT
X
SR
BL
STANDARD TW
1W
C
1
3
SA
PT
X
SR
BL
2W
C
1
3
SA
PT
X
SR
BL
PREMIUM TW
1W
B
1
3
SA
AT
RU
SR
BL
2W
B
1
3
SA
AT
RU
SR
BL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE TW
POWER
MODULE
SYSTEM
OPTIONS
COLOR
1W
F
CB
CBS
X
SR
BL
2W
F
CB
CBS
X
SR
BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE TW
POWER
MODULE
SYSTEM
OPTIONS
COLOR
1W
Z
CB
ADE ADP
SR
BL
2W
Z
CB
ADE ADP
SR
BL
FZLV SYSTEM CONFIGURATION CODE TW
POWER
SYSTEM
1W
FZLV
SR
COLOR BL
2W
FZLV
SR
BL
LEGEND: TW – fixture TWINS E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SE – non-maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring CB – central battery version CBS – central battery for circuit monitoring ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC SR – silver color BL – black color
71
emergency exit signs PLEXI LED
DIMENSIONS (mm):
45
170
315
210
325
160
MATERIALS: Steel body in grey or white color Plexi glass MOUNTING: Recessed (ceiling) POWER SUPPLY: Self contained – 220÷240VAC/50÷60Hz Central battery – 220÷240VAC/50÷60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W LED CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: I or III IP RATING: IP20 VIEWING DISTANCE: 30m AMBIENT TEMPERATURE: ta: 0°C÷40°C OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button AT – autotest RU – Rubic UNA central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection III class of insulation of FZLV version
355
110
b
RECESSING CUT (mm): • ceiling
h
65 x 330 x 110
220-240V AC 50-60Hz
176-275V DC
24V DC
LED
IP20
Ni-Cd
LiFePO4 d=30m
*see pictogram
*1pc of universal pictogram is included in each single box Current list of products with Kitemark and ENEC is available at www.awex.eu
72
KM 61835 BS-EN
emergency exit signs SELF-CONTAINED CONFIGURATION: CODE
POWER
MODULE
AUTONOMY [h]
MODE
OPTIONS
COLOR
BASIC PL
1W
E
1
3
SE
PT
X
GR WH
STANDARD PL
1W
C
1
3
SA
PT
X
GR WH
2W
C
1
3
SA
PT
X
GR WH
PREMIUM PL
1W
B
1
3
SA
AT
RU
GR WH
2W
B
1
3
SA
AT
RU
GR WH
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE PL
POWER
MODULE
SYSTEM
OPTIONS
COLOR
1W
F
CB
CBS
X
GR WH
2W
F
CB
CBS
X
GR WH
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE PL
POWER
MODULE
SYSTEM
1W
Z
CB
ADE ADP GR WH
OPTIONS
COLOR
2W
Z
CB
ADE ADP GR WH
FZLV SYSTEM CONFIGURATION CODE PL
POWER
SYSTEM
COLOR
1W
FZLV
GR WH
2W
FZLV
GR WH
LEGEND: PL – fixture PLEXI LED E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SE – non-maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring CB – central battery version CBS – central battery for circuit monitoring ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC WH – white color GR – grey color
73
emergency exit signs ESCAPE LED
DIMENSIONS (mm):
352
228 220-240V AC 50-60Hz
176-275V DC
74
24V DC
LED
IP20
Ni-Cd
LiFePO4 d=30m
*see pictogram
*1pc of universal pictogram is included in each single box Current list of products with Kitemark and ENEC is available at www.awex.eu
60
69
MATERIALS: Steel body in white color Plexi glass MOUNTING: Surface (ceiling) POWER SUPPLY: Self contained – 220 - 240VAC/50 - 60Hz Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W LED CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: I or III IP RATING: IP20 VIEWING DISTANCE: 30m AMBIENT TEMPERATURE: ta: 0°C÷40°C OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button AT – autotest RU – Rubic UNA central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection III class of insulation of FZLV version
KM 61835 BS-EN
emergency exit signs SELF-CONTAINED CONFIGURATION: CODE
POWER
MODULE
AUTONOMY [h]
MODE
OPTIONS
BASIC EL
1W
E
1
3
SE
PT
X
STANDARD EL
1W
C
1
3
SA
PT
X
2W
C
1
3
SA
PT
X
1W
B
1
3
SA
AT
RU
2W
B
1
3
SA
AT
RU
PREMIUM EL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE EL
POWER
MODULE
SYSTEM
1W
F
CB
CBS
OPTIONS X
2W
F
CB
CBS
X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE EL
POWER
MODULE
SYSTEM
OPTIONS
1W
Z
CB
ADE ADP
2W
Z
CB
ADE ADP
FZLV SYSTEM CONFIGURATION CODE EL
POWER
SYSTEM
1W
FZLV
2W
FZLV
LEGEND: EL – fixture ESCAPE LED E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SE – non-maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring CB – central battery version CBS – central battery for circuit monitoring ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC
75
emergency exit signs HELIOS & HELIOS LED
DIMENSIONS (mm):
136
MATERIALS: White polycarbonate body Transparent cover with Fresnel optics or opal polycarbonate cover MOUNTING: Surface (wall) Optional assembly with wall or ceiling bracket POWER SUPPLY: Self contained – 220 - 240VAC/50 - 60Hz Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W LED 8W fluorescent lamp CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP42 or IP65 VIEWING DISTANCE: 25m AMBIENT TEMPERATURE: ta: 0°C÷40°C ta: -25°C ÷ 40°C – together with heater for low temperatures OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button AT – autotest RU – Rubic UNA central monitoring RW – RUBIC UNA Wireless central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection Protection against mechanical impacts – IK08 III class of insulation of FZLV version
220-240V AC 50-60Hz
176-275V DC
76
24V DC
LED
T5 G5
IP42
IP65
Ni-Cd
LiFePO4
*see pictogram
*1pc of universal pictogram is included in each single box Current list of products with Kitemark and ENEC is available at www.awex.eu
79
356
KM 61835 BS-EN
emergency exit signs SELF-CONTAINED CONFIGURATION: CODE
POWER
MODULE
AUTONOMY [h]
MODE
OPTIONS
COVER
BASIC HL HEL
1W
E
1
3
SE
PT
X
OP
STANDARD HL HEL
1W
C
1
3
SA
PT
X
OP
2W
C
1
3
SA
PT
X
OP
PREMIUM 1W
B
1
3
SA
AT RU RW
OP
2W
B
1
3
SA
AT RU RW
OP
CODE
POWER
MODULE
MODE
OPTIONS
COVER
H HE
8W
T
SE SA
PT
HL HEL
AUTONOMY [h] 1
3
TF
AT
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE HL HEL H HE
POWER
MODULE
SYSTEM
1W
F
CB
CBS
OPTIONS X
COVER OP
2W
F
CB
CBS
X
OP
8W
T
CB
CBS
X
TF
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE HL HEL H HE
POWER
MODULE
SYSTEM
OPTIONS
COVER
1W
Z
CB
ADE ADP
OP
2W
Z
CB
ADE ADP
OP
8W
T
CB
ADL ADS
TF
FZLV SYSTEM CONFIGURATION CODE HL HEL
POWER
SYSTEM
COVER
1W
FZLV
OP
2W
FZLV
OP
LEGEND: HEL – fixture Helios led IP42 HL – fixture Helios led IP65 HE – fixture Helios IP42 H – fixture Helios IP65 E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings T – electronic gear for LFL fittings SE – non-maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring RW – RUBIC UNA Wireless central monitoring CB – central battery version CBS – central battery for circuit monitoring ADL – central battery with ADL module ADS – central battery with ADS address module – SMART technology ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC TF – transparent cover with Fresnel optics OP – opal polycarbonate cover
77
emergency exit signs HELIOS DS & HELIOS DS LED
DIMENSIONS (mm):
356
33
220-240V AC 50-60Hz
176-275V DC
78
24V DC
LED
T5 G5
IP42
Ni-Cd
IP65
LiFePO4 d=25m
*see pictogram
*1pc of universal pictogram is included in each single box Current list of products with Kitemark and ENEC is available at www.awex.eu
136
219
MATERIALS: White polycarbonate body Opal polycarbonate cover MOUNTING: Surface (ceiling) POWER SUPPLY: Self contained – 220 - 240VAC/50 - 60Hz Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W LED 8W fluorescent lamp CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP42 or IP65 VIEWING DISTANCE: 25m AMBIENT TEMPERATURE: ta: 0°C÷40°C ta: -25°C ÷ 40°C – together with heater for low temperatures OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button AT – autotest RU – Rubic UNA central monitoring RW – RUBIC UNA Wireless central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection Protection against mechanical impacts – IK08 III class of insulation of FZLV version
KM 61835 BS-EN
emergency exit signs SELF-CONTAINED CONFIGURATION: CODE
POWER
MODULE
AUTONOMY [h]
MODE
OPTIONS
BASIC HDL
HDEL
1W
E
1
3
SE
PT
X
STANDARD HDL
HDEL
1W
C
1
3
SA
PT
X
2W
C
1
3
SA
PT
X
PREMIUM HDL
HDEL
CODE HD
HDE
1W
B
1
3
SA
AT RU RW
2W
B
1
3
SA
AT RU RW
POWER
MODULE
MODE
OPTIONS
8W
T
SE SA
PT
AUTONOMY [h] 1
3
PT
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE HDL
HDEL
HD
HDE
POWER
MODULE
SYSTEM
1W
F
CB
CBS
OPTIONS X
2W
F
CB
CBS
X
8W
T
CB
CBS
X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE HDL
HDEL
HD
HDEL
POWER
MODULE
SYSTEM
OPTIONS
1W
Z
CB
ADE ADP
2W
Z
CB
ADE ADP
8W
T
CB
ADL ADS
FZLV SYSTEM CONFIGURATION CODE HDL
HDEL
POWER
SYSTEM
1W
FZLV
2W
FZLV
LEGEND: HDEL – fixture Helios DS led IP42 HDL – fixture Helios DS led IP65 HDE – fixture Helios DS IP42 HD – fixture Helios DS IP65 E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings T – electronic gear for LFL fittings; SE – non-maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring RW – RUBIC UNA Wireless central monitoring CB – central battery version CBS – central battery for circuit monitoring ADL – central battery with ADL module ADS – central battery with ADS address module – SMART technology ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC
79
emergency exit signs TIGER & TIGER LED
DIMENSIONS (mm):
144
323
118
MATERIALS: White polycarbonate body Transparent or opal polycarbonate cover MOUNTING: Surface (wall) Optionally recessed (wall**) POWER SUPPLY: Self contained – 220 - 240VAC/50 - 60Hz Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W LED 8W fluorescent lamp CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP22 VIEWING DISTANCE: 20m AMBIENT TEMPERATURE: ta: 0°C÷40°C OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button AT – autotest RU – Rubic UNA central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection III class of insulation of FZLV version **requires an accessory for recessed mounting
350
RECESSING CUT (mm): • wall
325 x 120
220-240V AC 50-60Hz
176-275V DC
24V DC
LED
T5 G5
IP22
Ni-Cd
LiFePO4 d=20m
*see pictogram
*1pc of universal pictogram is included in each single box Current list of products with Kitemark and ENEC is available at www.awex.eu
80
KM 61835 BS-EN
emergency exit signs SELF-CONTAINED CONFIGURATION: CODE
POWER
MODULE
AUTONOMY [h]
MODE
OPTIONS
COVER
BASIC TL
1W
E
1
3
SE
PT
X
OP
STANDARD TL
1W
C
1
3
SA
PT
X
OP
2W
C
1
3
SA
PT
X
OP
PREMIUM 1W
B
1
3
SA
AT
RU
OP
2W
B
1
3
SA
AT
RU
OP
CODE
POWER
MODULE
TG
8W
T
TL
AUTONOMY [h] 1
3
MODE
OPTIONS
SE SA
PT
AT
COVER TR
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE TL TG
POWER
MODULE
SYSTEM
1W
F
CB
CBS
OPTIONS X
COVER OP
2W
F
CB
CBS
X
OP
8W
T
CB
CBS
X
TR
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE TL TG
POWER
MODULE
SYSTEM
OPTIONS
COVER
1W
Z
CB
ADE ADP
OP
2W
Z
CB
ADE ADP
OP
8W
T
CB
ADL ADS
TR
FZLV SYSTEM CONFIGURATION CODE TL
POWER
SYSTEM
1W
FZLV
COVER OP
2W
FZLV
OP
LEGEND: TG – fixture Tiger TL – fixture Tiger LED E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings T – electronic gear for LFL fittings SE – non-maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring system CB – central battery version CBS – central battery for circuit monitoring ADL – central battery with ADL module ADS – central battery with ADS address module – SMART technology ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC TR – transparent polycarbonate cover OP – opal polycarbonate cover
81
emergency exit signs TIGER DS & TIGER DS LED
DIMENSIONS (mm):
323
118
350
144
186
MATERIALS: White polycarbonate body Opal polycarbonate cover MOUNTING: Surface (ceiling) Optionally recessed (ceiling**) POWER SUPPLY: Self contained – 220 - 240VAC/50 - 60Hz Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 1W, 2W LED 8W fluorescent lamp CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 3,6V batteries STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II or III IP RATING: IP22 VIEWING DISTANCE: 20m AMBIENT TEMPERATURE: ta: 0°C÷40°C OPTIONS: SE – non maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button AT – autotest RU – Rubic UNA central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection III class of insulation of FZLV version **requires an accessory for recessed mounting
RECESSING CUT (mm): • wall
325 x 120
220-240V AC 50-60Hz
176-275V DC
24V DC
LED
T5 G5
IP22
Ni-Cd
LiFePO4 d=20m
*see pictogram
*1pc of universal pictogram is included in each single box Current list of products with Kitemark and ENEC is available at www.awex.eu
82
KM 61835 BS-EN
emergency exit signs SELF-CONTAINED CONFIGURATION CODE
POWER
MODULE
AUTONOMY [h]
MODE
OPTIONS
BASIC TSL
1W
E
1
3
SE
PT
X
STANDARD 1W
C
1
3
SA
PT
X
2W
C
1
3
SA
PT
X
1W
B
1
3
SA
AT
RU
2W
B
1
3
SA
AT
RU
CODE
POWER
MODULE
TGS
8W
T
TSL
PREMIUM TSL
AUTONOMY [h] 1
3
MODE
OPTIONS
SE SA
PT
AT
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE TSL TGS
POWER
MODULE
SYSTEM
1W
F
CB
CBS
OPTIONS X
2W
F
CB
CBS
X
8W
T
CB
CBS
X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE TSL TGS
POWER
MODULE
SYSTEM
OPTIONS
1W
Z
CB
ADE ADP
2W
Z
CB
ADE ADP
8W
T
CB
ADL ADS
FZLV SYSTEM CONFIGURATION CODE TSL
POWER
SYSTEM
1W
FZLV
2W
FZLV
LEGEND: TGS – fixture Tiger DS TSL – fixture Tiger DS LED E – electronic gear for BASIC self-contained fittings C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings T – electronic gear for LFL fittings SE – non-maintained SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring system CB – central battery version CBS – central battery for circuit monitoring ADL – central battery with ADL module ADS – central battery with ADS address module – SMART technology ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC
83
emergency exit signs SCREEN
DIMENSIONS (mm):
b
MATERIALS: Aluminium body Plexi glass MOUNTING: Surface (wall) POWER SUPPLY: self contained – 220÷240VAC/50÷60Hz central battery – 220÷240VAC/50÷60Hz; 176 - 275VDC central battery FZLV – 24VDC LIGHT SOURCE: SC30 3x1W; SC40 3W; SC60 2x3W LED CHARGING: STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: I or III IP RATING: IP40 VIEWING DISTANCE: 30, 40 or 60m (depends on version) AMBIENT TEMPERATURE: ta: 0°C ÷ 40°C OPTIONS: SA – maintained (with an option of connecting as non-maintained) PT – manual test button AT – autotest RU – Rubic UNA central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charging Deep discharge protection III class of insulation of FZLV version
c
a
d
Dimensions [mm] TYPE
a[mm]
b[mm]
c[mm]
SC30
315
165
50
8
SC40
415
215
50
8
SC60
615
315
50
8
220-240V AC 50-60Hz
176-275V DC
24V DC
d[mm]
LED
IP40
Ni-Cd
LiFePO4 d=30m
d=40m
d=60m
*see pictogram
*1pc of universal pictogram is included in each single box Current list of products with Kitemark and ENEC is available at www.awex.eu
84
KM 61835 BS-EN
emergency exit signs SELF-CONTAINED CONFIGURATION CODE
POWER
MODULE
AUTONOMY [h]
MODE
OPTIONS
STANDARD SC30
3x1W
C
1
3
SA
PT
X
SC40
3W
C
1
3
SA
PT
X
SC60
2x3W
C
1
3
SA
PT
X
PREMIUM SC30
3x1W
B
1
3
SA
AT
RU
SC40
3W
B
1
3
SA
AT
RU
SC60
2x3W
B
1
3
SA
AT
RU
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE
POWER
MODULE
SYSTEM
SC30
3x1W
F
CB
CBS
OPTIONS X
SC40
3W
F
CB
CBS
X
SC60
2x3W
F
CB
CBS
X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE
POWER
MODULE
SYSTEM
OPTIONS
SC30
3x1W
Z
CB
ADE ADP
SC40
3W
Z
CB
ADE ADP
SC60
2x3W
Z
CB
ADE ADP
FZLV SYSTEM CONFIGURATION CODE
POWER
SYSTEM
SC30
3x1W
FZLV
SC40
3W
FZLV
SC60
2x3W
FZLV
LEGEND: SC30 – fixture Screen viewing distance 30m SC40 – fixture Screen viewing distance 40m SC60 – fixture Screen viewing distance 60m C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring system CB – central battery version CBS – central battery for circuit monitoring ADP – central battery with ADP address module – SMART technology ADE – central battery with ADE address module FZLV – central battery FZLV 24 VDC
85
emergency exit signs SCREEN DS
DIMENSIONS (mm):
b
MATERIALS: Aluminium body Plexi glass MOUNTING: Surface (ceiling) Optionally mounting on a rope sling (ceiling**) POWER SUPPLY: self contained – 220÷240VAC/50÷60Hz central battery – 220÷240VAC/50÷60Hz; 176 - 275VDC central battery FZLV – 24VDC LIGHT SOURCE: SCS30 3x1W; SCS40 3W; SCS60 2x3W LED CHARGING: STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: I or III IP RATING: IP40 VIEWING DISTANCE: 30, 40 or 60m (depends on version) AMBIENT TEMPERATURE: ta: 0°C ÷ 40°C OPTIONS: SA – maintained (with an option of connecting as non-maintained) PT – manual test button AT – autotest RU – Rubic UNA central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charging Deep discharge protection III class of insulation of FZLV version **requires an accessory for mounting on a rope sling
c
a
Dimensions [mm] TYPE
a[mm]
b[mm]
SCS30
315
165
50
SCS40
415
215
50
SCS60
615
315
50
220-240V AC 50-60Hz
176-275V DC
24V DC
c[mm]
LED
IP40
Ni-Cd
LiFePO4 d=30m
d=40m
d=60m
*see pictogram
*1pc of universal pictogram is included in each single box Current list of products with Kitemark and ENEC is available at www.awex.eu
86
KM 61835 BS-EN
emergency exit signs SELF-CONTAINED CONFIGURATION CODE
POWER
MODULE
AUTONOMY [h]
MODE
OPTIONS
STANDARD SCS30
3x1W
C
1
3
SA
PT
X
SCS40
3W
C
1
3
SA
PT
X
SCS60
2x3W
C
1
3
SA
PT
X
PREMIUM SCS30
3x1W
B
1
3
SA
AT
RU
SCS40
3W
B
1
3
SA
AT
RU
SCS60
2x3W
B
1
3
SA
AT
RU
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE
POWER
MODULE
SYSTEM
SCS30
3x1W
F
CB
CBS
OPTIONS X
SCS40
3W
F
CB
CBS
X
SCS60
2x3W
F
CB
CBS
X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE
POWER
MODULE
SYSTEM
OPTIONS
SCS30
3x1W
Z
CB
ADE ADP
SCS40
3W
Z
CB
ADE ADP
SCS60
2x3W
Z
CB
ADE ADP
FZLV SYSTEM CONFIGURATION CODE
POWER
SYSTEM
SCS30
3x1W
FZLV
SCS40
3W
FZLV
SCS60
2x3W
FZLV
LEGEND: SCS30 – fixture Screen DS viewing distance 30m SCS40 – fixture Screen DS viewing distance 40m SCS60 – fixture Screen DS viewing distance 60m C – electronic gear for STANDARD self-contained fittings B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring system CB – central battery version CBS – central battery for circuit monitoring ADP – central battery with ADP address module – SMART technology ADE – central battery with ADE address module FZLV – central battery FZLV 24 VDC
87
emergency exit signs QUADRO
DIMENSIONS (mm):
240
MATERIALS: Opal plexi glass body MOUNTING: Surface (ceiling) POWER SUPPLY: Self contained – 220 - 240VAC/50 - 60Hz Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 3x1W LED CHARGING: STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: STANDARD: 1h or 3h, Ni-Cd 3,6V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: I or III IP RATING: IP41 VIEWING DISTANCE: 25m AMBIENT TEMPERATURE: ta: 0°C÷40°C OPTIONS: SE – non maintained SA – maintained PT – manual test button AT – autotest RU – Rubic UNA central monitoring FZLV – central battery FZLV 24VDC CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection III class of insulation of FZLV version
240
220-240V AC 50-60Hz
176-275V DC
24V DC
LED
Ni-Cd
LiFePO4 d=25m
*see pictogram
*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.
88
emergency exit signs SELF-CONTAINED CONFIGURATION CODE
POWER
MODULE
AUTONOMY [h]
MODE
OPTIONS
STANDARD Q
3x1W
C
1
3
SA
PT
X
3
SA
AT
RU
PREMIUM Q
3x1W
B
1
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE
POWER
MODULE
SYSTEM
Q
3x1W
F
CB
OPTIONS CBS
X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE
POWER
MODULE
SYSTEM
OPTIONS
Q
3x1W
Z
CB
ADE ADP
FZLV SYSTEM CONFIGURATION CODE
POWER
SYSTEM
Q
3x1W
FZLV
Legend: Q – fixture Quadro C – electronic gear for STANDARD self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring system CB – central battery version CBS – central battery for circuit monitoring ADL – central battery with ADL module ADS – central battery with ADS address module – SMART technology ADE – central battery with ADE address module ADP – central battery with ADP address module – SMART technology FZLV – central battery FZLV 24 VDC
89
Special application luminaires IKLED
92
ESCAPELITE
94
ESCAPELITE L
95
FLAGLIGHT
96
WALL LINE
97
IKLED
ESCAPELITE
ESCAPELITE L
FLAGLIGHT
WALL LINE
Special application luminaires IKLED
DIMENSIONS (mm):
238
MATERIALS: Stainless steel or painted steel body Tempered glass or plexi glass MOUNTING: Surface (wall, ceiling) Optionally recessed* (wall, ceiling) POWER SUPPLY: Self contained – 220 - 240VAC/50 - 60Hz Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC Central battery FZLV – 24VDC LIGHT SOURCE: 3W or 6W LED CHARGING: Maximum 12h; energy-saving electronic impulse charger AUTONOMY AND BATTERIES: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: I or III IP&KPA RATING: IP65, 10KPA VIEWING DISTANCE: 30m AMBIENT TEMPERATURE: ta: 0°C÷40°C ta: -25°C ÷ 40°C – together with heater for low temperatures OPTIONS: SA – maintained (with an option of connecting as non-maintained) PT – manual test button AT – autotest RU – Rubic UNA central monitoring CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection III class of insulation of FZLV version Optional adaptation of the fixture for low temperatures up to -25°C
220-240V AC 50-60Hz
176-275V DC
IP65
*see pictogram
*Pictograms for tunnel luminaires have to be ordered separately and according to the local requirements.
92
61
408
24V DC
IK10
LED
LiFePO4 d=30m
Special application luminaires SELF-CONTAINED CONFIGURATION CODE IK
IKP
AUTONOMY [h]
MODE
COLOR
POWER
MODULE
3W
B
1
3
SA
OPTIONS AT
RU
WH
GR
BL
6W
B
1
3
SA
AT
RU
WH
GR
BL
3W
B
1
3
SA
AT
RU
ST
6W
B
1
3
SA
AT
RU
ST
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE IK
IKP
POWER
MODULE
SYSTEM
3W
F
CB
CBS
OPTIONS X
WH
GR
BL
6W
F
CB
CBS
X
WH
GR
BL
3W
F
CB
CBS
X
ST
6W
F
CB
CBS
X
ST
COLOR
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE COLOR
CODE
POWER
MODULE
SYSTEM
OPTIONS
ESC IK
3W
Z
CB
ADP
WH
GR
BL
6W
Z
CB
ADP
WH
GR
BL
ESC IKP
3W
Z
CB
ADP
ST
6W
Z
CB
ADP
ST
FZLV SYSTEM CONFIGURATION CODE
POWER
SYSTEM
IK
3W
FZLV
IKP
3W
FZLV
COLOR WH
GR
BL
ST
Legend: IK – fitting IKLED with steel painted body and plexi glass IKP – fitting IKLED with steel stainless body and tempered glass B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SA – maintained (with an option of connecting as non-maintained) X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring CB – central battery version CBS – central battery for circuit monitoring ADP – central battery with ADP address module – SMART technology WH – white color GR – grey color BL – black color ST – stainless steel *Pictograms for tunnel luminaires have to be ordered separately and according to the local requirements.
93
Special application luminaires ESCAPELITE MATERIALS: Stainless steel body Tempered glass (5mm) MOUNTING: Surface (wall) POWER SUPPLY: Self contained – 220 - 240VAC/50 - 60Hz Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC LIGHT SOURCE: 3x1W LED CHARGING: Maximum 12h; energy-saving electronic impulse charger AUTONOMY AND BATTERIES: 1, 3h, high temperature Ni-CD batteries INSULATION CLASS: I IP&KPA RATING: IP65, 10KPA VIEWING DISTANCE: 40m AMBIENT TEMPERATURE: ta: 0°C÷40°C OPTIONS: SA – maintained (with an option of connecting as non-maintained) PT – manual test button AT – autotest RU – Rubic UNA central monitoring CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection
312
DIMENSIONS (mm):
223
491
SELF-CONTAINED CONFIGURATION CODE
POWER
MODULE
ESC
3W
B
AUTONOMY [h] 1
3
MODE
OPTIONS
SA
PT
AT
POWER
MODULE
SYSTEM
ESC
3W
F
CB
176-275V DC
LED
IP65
RU IK10
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE
220-240V AC 50-60Hz
Ni-Cd d=40m
OPTIONS CBS
X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE
POWER
MODULE
SYSTEM
OPTIONS
ESC
3W
Z
CB
ADP
*see pictogram
Legend: ESC – fitting ESCAPELITE B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring CB – central battery version CBS – central battery for circuit monitoring ADP – central battery with ADP address module – SMART technology *Pictograms for tunnel luminaires have to be ordered separately and according to the local requirements.
94
KM 61835 BS-EN
Special application luminaires ESCAPELITE L MATERIALS: Stainless steel body Tempered glass (5mm) MOUNTING: Surface (wall) POWER SUPPLY: Self contained – 220 - 240VAC/50 - 60Hz Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC LIGHT SOURCE: 3x1W LED CHARGING: Maximum 12h; energy-saving electronic impulse charger AUTONOMY AND BATTERIES: 1, 3h, high temperature Ni-CD batteries INSULATION CLASS: I IP&KPA RATING: IP65, 10KPA VIEWING DISTANCE: 30m AMBIENT TEMPERATURE: ta: 0°C÷40°C OPTIONS: SA – maintained (with an option of connecting as non-maintained) PT – manual test button AT – autotest RU – Rubic UNA central monitoring CB – central battery ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection
222
DIMENSIONS (mm):
506
SELF-CONTAINED CONFIGURATION CODE
POWER
MODULE
ESL
3W
B
AUTONOMY [h] 1
3
MODE
OPTIONS
SA
PT
AT
POWER
MODULE
SYSTEM
ESL
3W
F
CB
176-275V DC
Ni-Cd
OPTIONS CBS
X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE CODE
POWER
MODULE
SYSTEM
OPTIONS
ESL
3W
Z
CB
ADP
*see pictogram
Legend: ESL – fitting ESCAPELITE L B – electronic gear for PREMIUM self-contained fittings F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings SA – maintained (with an option of connecting as non-maintained) PT – manual test button X – fitting without additional options AT – autotest RU – RUBIC UNA central monitoring CB – central battery version CBS – central battery for circuit monitoring ADP – central battery with ADP address module – SMART technology *Pictograms for tunnel luminaires have to be ordered separately and according to the local requirements.
95
LED
RU IK10
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE
220-240V AC 50-60Hz
366
d=30m
IP65
Special application luminaires FLAGLIGHT MATERIALS: Stainless steel body Plexi glass MOUNTING: Surface (wall) POWER SUPPLY: Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC LIGHT SOURCE: 20x1W LED INSULATION CLASS: I IP&KPA RATING: IP65, 10KPA VIEWING DISTANCE: 60m AMBIENT TEMPERATURE: ta: 0°C÷40°C OPTIONS: CB – central battery DIMENSIONS (mm): CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE CODE
POWER
MODULE
SYSTEM
FLA
20x1W
F
CB
OPTIONS CBS
X
CODE
POWER
MODULE
SYSTEM
OPTIONS
FLA
20x1W
Z
CB
ADS
396
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
478
220-240V AC 50-60Hz
176-275V DC
IK10
Legend: FLA – fitting FLAGLIGHT F – electronic gear for central battery fittings Z – electronic gear for addressable central battery fittings CBS – central battery for circuit monitoring ADS – central battery with ADS address module – SMART technology *Pictograms for tunnel luminaires have to be ordered separately and according to the local requirements.
96
150
LED
d=60m
IP65
Special application luminaires WALL LINE MATERIALS: Stainless steel body Plexi glass MOUNTING: Surface (wall) POWER SUPPLY: Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC LIGHT SOURCE: max. 2W – high intensity led INSULATION CLASS: I IP RATING: IP65 AMBIENT TEMPERATURE: ta: 0°C÷40°C OPTIONS: DES – dynamic escape system ADDITIONAL INFORMATION: Luminaire cooperates only with the dynamic escape sign system DES Luminaire indicate red or green light according to scenerios from DES. Possibility to connect several segments together
112
DIMENSIONS (mm):
820
CONFIGURATION CODE
POWER
SYSTEM
OPTIONS
WLL
2W
CB
DES
140
220-240V AC 50-60Hz
176-275V DC
DES
Legend: WLL – fixture WALL LINE CB – central battery DES – dynamic escape system *Pictograms for tunnel luminaires have to be ordered separately and according to the local requirements.
97
LED
IP65
emergency conversion kits NEXT & NEXT AUTOTEST
100
UNILED GU10
101
UNILED BM
102
UNILED UM
104
EML
106
NEXT & NEXT AUTOTEST
UNILED GU10
UNILED BM
UNILED UM
EML
emergency conversion kits NEXT & NEXT AUTOTEST
35
DIMENSIONS (mm):
42
MATERIALS: Polycarbonate body MOUNTING: Inside the fixture POWER SUPPLY: 230 VAC/50-60 Hz LIGHT SOURCE: Linear and compact fluorescent lamps CHARGING: Maximum 24h AUTONOMY AND BATTERIES: 1h or 3h; Ni-Cd battery INSULATION CLASS: II IP RATING: IP20 AMBIENT TEMPERATURE: ta: 0°C÷55°C ta: -25°C ÷ 55°C – together with heater for low temperatures OPTIONS: PT – manual test button AT – autotest ADDITIONAL INFORMATION: A new generation of conversion kits which replaces conversion kits series LIDER LED indicator signalizes mains power supply and battery charge Deep discharge protection Cooperation with magnetic and electronic ballasts Optional adaptation of conversion kit for low temperatures up to -25°C
157
NEXT – ORDER CODES CODE
POWER [W]
AUTONOMY [h]
OPTION
BATTERY
NX/36/1
6 – 36
1
PT
Ni-Cd 3,6V 1,5Ah
NX/36/3
6 – 36
3
PT
Ni-Cd 3,6V 4,0Ah
NX/58/1
6 – 58
1
PT
Ni-Cd 4,8V 1,5Ah
NX/58/3
6 – 58
3
PT
Ni-Cd 4,8V 4,0Ah
NX/80/1
6 – 80
1
PT
Ni-Cd 6,0V 1,5Ah
NX/80/3
6 – 80
3
PT
Ni-Cd 6,0V 4,0Ah
230V AC 50-60Hz
IP20
Ni-Cd
NEXT AUTOTEST – ORDER CODES CODE
POWER [W]
AUTONOMY [h]
BATTERY
NX/36/1/AT
6 – 36
1
Ni-Cd 3,6V 2,0Ah
NX/36/3/AT
6 – 36
3
Ni-Cd 3,6V 4,5Ah
NX/58/1/AT
6 – 58
1
Ni-Cd 4,8V 2,0Ah
NX/58/3/AT
6 – 58
3
Ni-Cd 4,8V 4,5Ah
NX/80/1/AT
6 – 80
1
Ni-Cd 6,0V 2,0Ah
NX/80/3/AT
6 – 80
3
Ni-Cd 6,0V 4,5Ah
KM 618354 BS-EN 61347-2-7
Test types (version AT): LED INDICATOR LED color
Signal
Symbolizing
no signal
emergency mode / running test
shining
defective battery
flashing
defective lamp
no signal
emergency mode / running test
shining
normal mode
flashing
normal mode, battery charging
Current list of products with Kitemark and ENEC is available at www.awex.eu
100
Test A is run automatically every 28 days During test A a conversion kit is switched to emergency mode for 1 minute and the following parameters are checked: • control of battery power discharge • control of battery voltage Test B is run automatically every 364 days During test B a conversion kit is switched to emergency mode for all duration time (1, 2, 3 hours) and the following parameters are checked: • control of battery power discharge • control of minimum battery voltage
emergency conversion kits
Uniled GU10 – ORDER CODE CODE
POWER [W]
AUTONOMY [h]
OPTION
BATTERY
GU10/1
3,5 – 8
1
PT
Ni-CD 7,2V 1,5Ah
GU10/3
3,5 – 8
3
PT
Ni-CD 7,2V 4,0Ah
101
42
MATERIALS: Polycarbonate body MOUNTING: Inside the fixture POWER SUPPLY: 230VAC/50-60Hz LIGHT SOURCE: 3,5–8W LED CHARGING: Maximum 24h AUTONOMY AND BATTERIES: 1h or 3h; Ni-Cd battery INSULATION CLASS: II IP RATING: IP20 AMBIENT TEMPERATURE: ta: 0°C÷40°C OPTIONS: PT – manual test button ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection Designed for cooperation with LED light sources with voltage 180VDC In emergency mode light stream is 80% of the nominal stream
35
UNILED GU10
157
230V AC 50-60Hz
IP20
Ni-Cd
emergency conversion kits UNILED BM
22
DIMENSIONS (mm):
38
MATERIALS: Polycarbonate body MOUNTING: Inside the fixture POWER SUPPLY: 220÷240 VAC/50-60 Hz LIGHT SOURCE: 1W, 2W, 3W, 6W*, LED CHARGING: STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: STANDARD: 1h or 3h, Ni-Cd 4,8V batteries PREMIUM: 1h or 3h, LiFePO4 6,4V batteries INSULATION CLASS: II IP RATING: IP20 AMBIENT TEMPERATURE: ta: 0°C÷40°C ta: -25°C ÷ 55°C – together with heater for low temperatures OPTIONS: PT – manual test button AT – autotest ADDITIONAL INFORMATION: LED indicator signalizes mains power supply and battery charge Deep discharge protection Optional adaptation of conversion kit for low temperatures up to -25°C Automatic detection of battery capacity and setting test parameters Output voltage: 3.3 VDC Output curent: BM 1W – 350mA, BM 3W 1000mA, BM 6W – 2000mA * 6W – power of light source only in non-maintained fixtures
134
220-240V AC 50-60Hz
IP20
Ni-Cd
LiFePO4
KM 618354 BS-EN 61347-2-7
LED INDICATOR - UNILED BM STANDARD LED color
Signal
Symbolizing
no signal
emergency mode / Standby mode
shining
Standby mode (battery is full)
flashing
battery is being loaded, normal mode
LED INDICATOR - UNILED BM PREMIUM LED color
Signal
Symbolizing
no signal
emergency mode / running test
shining
defective battery
flashing
defective lamp
no signal
emergency mode / running test
shining
normal mode
flashing
battery is being loaded, normal mode
Current list of products with Kitemark and ENEC is available at www.awex.eu
102
Test types (version AT): Test A is run automatically every 28 days During test A a conversion kit is switched to emergency mode for 1 minute and the following parameters are checked: • control of battery power discharge • control of battery voltage Test B is run automatically every 364 days During test B a conversion kit is switched to emergency mode for all duration time (1, 2, 3 hours) and the following parameters are checked: • control of battery power discharge • control of minimum battery voltage
emergency conversion kits UNILED BM STANDARD – ORDER CODES CODE
POWER [W]
AUTONOMY [h]
OPTION
BATTERY
1
PT
Ni-CD 4,8V 1,0Ah
BM/1/1/PT/CD BM/1/3/PT/CD
3
PT
Ni-CD 4,8V 1,5Ah
BM/1/8/PT/CD
8
PT
Ni-CD 4,8V 4,0Ah
BM/2/1/PT/CD
1
PT
Ni-CD 4,8V 1,0Ah
3
PT
Ni-CD 4,8V 2,5Ah
1
PT
Ni-CD 4,8V 1,5Ah
BM/3/3/PT/CD
3
PT
Ni-CD 4,8V 4,0Ah
BM/6/1/PT/CD
1
PT
Ni-CD 4,8V 4,0Ah
3
PT
Ni-CD 4,8V 8,0Ah
AUTONOMY [h]
OPTION
BATTERY
1
AT
LiFePO4 6,4V 1,0Ah
BM/2/3/PT/CD BM/3/1/PT/CD
BM/6/3/PT/CD
1
2
3
6
UNILED BM PREMIUM – ORDER CODES CODE
POWER [W]
BM/1/1/AT/Li BM/1/3/AT/Li
3
AT
LiFePO4 6,4V 1,0Ah
BM/1/8/AT/Li
8
AT
LiFePO4 6,4V 3,0Ah
BM/2/1/AT/Li
1
AT
LiFePO4 6,4V 1,0Ah
3
AT
LiFePO4 6,4V 2,0Ah
1
AT
LiFePO4 6,4V 1,5Ah
BM/3/3/AT/Li
3
AT
LiFePO4 6,4V 3,0Ah
BM/6/1/AT/Li
1
AT
LiFePO4 6,4V 3,0Ah
3
AT
LiFePO4 6,4V 6,0Ah
BM/2/3/AT/Li BM/3/1/AT/Li
BM/6/3/AT/Li
103
1
2
3
6
emergency conversion kits UNILED UM
35
DIMENSIONS (mm):
42
MATERIALS: Polycarbonate body MOUNTING: In the fixture Optional in additional housing* POWER SUPPLY: 220÷240VAC/50÷60Hz LIGHT SOURCE: Power mode: max 80W Designed for cooperation with LED light sources with voltage 12V - 90VDC - max 80W OUTPUT POWER: BASIC: 3W STANDARD, PREMIUM: 1 - 9W CHARGING: BASIC: max. 24h STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger AUTONOMY AND BATTERIES: BASIC: 1h or 3h, Ni-Cd 7,2V batteries STANDARD: 1h, 3h or 8h Ni-Cd 7,2V batteries PREMIUM: 1h, 3h or 8h, LiFePO4 9,6V batteries INSULATION CLASS: II IP RATING: IP20 AMBIENT TEMPERATURE: ta: 0°C÷50°C OPTIONS: PT – manual test button AT – autotest ADDITIONAL INFORMATION: Deep discharge protection Optional adaptation of conversion kit for low temperatures up to -25°C Automatic detection of battery capacity and setting test parameters Automatic detection of LED light source voltage in Power mode In emergency mode the incorrect settings are detected by LED indicator Autonomy 1h, 3h, 8h set by jumper **requires an accessory for Uniled UM housing
157
220-240V AC 50-60Hz
Ni-Cd
IP20
LiFePO4
POWER MODE LED power supply max. 80W
UNILED UM
LiFePO4
Ni-Cd
Type of battery
AUTONOMY [h] 1h
3h
8h
7,2V 1000mAh
3W
1W
–
7,2V 1500 mAh
4W
2W
1W
7,2V 2500mAh
8W
3W
1W
7,2V 4000mAh
9W
5W
2W
7,2V 8000mAh
9W
9W
4W
9,6V 1500mAh
6W
3W
1W
9,6V 3000mAh
9W
5W
2W
9,6V 6000mAh
9W
9W
4W
KM 618354 BS-EN 61347-2-7
SETTINGS Power mode, choice of output power in the range: 1W - 9W
Light output in emergency mode (only power mode) light output in emergency mode light output in mains mode
light output in emergency mode [lm]
=
LED power in emergency mode
=
LED power in emergency mode [W]
LED power in mains mode
LED power in mains mode [W]
Current list of products with Kitemark and ENEC is available at www.awex.eu
104
OFF
x
light output in mains mode [lm]
emergency conversion kits UNILED UM BASIC – ORDER CODES CODE
CONFIGURATION OF BATTERY PACKAGES
BATTERY CAPACITY
TYPE
10
CD
B1
25
CD
B1
UMB
PACKAGES
UNILED UM STANDARD – ORDER CODES CODE
BATTERY CAPACITY
UM
TYPE
OPTION
PACKAGES
10
CD
B1
B2
B3
PT
15
CD
B1
B2
B3
PT
25
CD
B1
B2
B3
PT
40
CD
B1
B2
B3
PT
80
CD
B1
B2
B3
PT
B4 UNILED UM PREMIUM – ORDER CODES CODE
BATTERY
OPTION
CAPACITY
TYPE
15
Li
B1
B2
B13
AT
30
Li
B1
B2
B13
AT
60
Li
B1
B2
B4
AT
UM
PACKAGES
LED indicator – uniled UM Basic/Standard LED color
LED indicator – uniled UM Premium
Signal
Symbolizing
Signal
Symbolizing
no signal
emergency mode / Standby mode
no signal
emergency mode / running test
shining
Standby mode (battery is full)
shining
defective battery
flashing
battery is being loaded, normal mode
flashing
defective lamp, too much output power for this battery capacity
no signal
emergency mode / running test
Legend: PT – manual test button AT – autotest UM – conversion kit Uniled UM UMB – conversion kit Uniled UM BASIC 10 – battery capacity 1000 mAh 15 – battery capacity 1500 mAh 25 – battery capacity 2500 mAh 30 – battery capacity 3000 mAh 40 – battery capacity 4000 mAh 60 – battery capacity 6000 mAh 80 – battery capacity 8000 mAh CD – battery type Ni-Cd Li – battery type LiFePO4 B1 – battery Stick B2 – battery Akku Pack B3 – battery Akku Pack block B4 – battery Akku Pack block B13 – battery Akku Pack block
105
B13
LED color
shining
normal mode
flashing
battery is being loaded, normal mode
Test types (version AT): Test A is run automatically every 28 days During test A a conversion kit is switched to emergency mode for 1 minute and the following parameters are checked: • control of battery power discharge • control of battery voltage Test B is run automatically every 364 days During test B a conversion kit is switched to emergency mode for all duration time (1, 2, 3 hours) and the following parameters are checked: • control of battery power discharge • control of minimum battery voltage
emergency conversion kits EML
22
DIMENSIONS (mm):
38
45
LED TYPE : POWER LED or LED SMD NUMBER OF LED DIODES: 1x power LED or 8x LED SMD or 20x LED SMD LIGHT SOURCE: 3W POWER SUPPLY: Self contained – 220÷240VAC/50÷60Hz CHARGING: STANDARD: max. 24h PREMIUM: max. 12h; energy-saving electronic charger INSULATION CLASS: II AMBIENT TEMPERATURE: ta: 0°C ÷ 55°C OPTIONS: SE – non maintained AT – autotest COLOR TEMPERATURE 6000 - 6500 K CRI: Ra>85 LUMINOUS EFFICIENCY 100 - 180 lm/W VIEWING ANGLE: 125° LIFETIME: 50000h DIMENSION: POWER LED: 45x45x4 mm LED SMD: 177x10x2,5 mm Conversion kit: 130x38x22 mm Batteries: *see table below
134 45
CONVERSION KIT
10
POWER LED
2,5 178
LED SMD
B
C
A
BATTERY
LED
220-240V AC 50-60Hz
106
2.9-3.2V
LiFePO4
125°
NiCD
50000h
60006500 K
emergency conversion kits SELF - CONTAINED CONFIGURATION CODE
POWER
AUTONOMY [h]
BATTERY
OPTIONS
1h
3h
STANDARD BMA
3W
1
3
PT
3,6V 1,5Ah
3,6V 4,0Ah
AT
6,4V 1,5Ah
6,4V 3,0Ah
PREMIUM BM
3W
1
3
BATTERY CONFIGURATION CODE
CAPACITY [mAh]
Li
CD
DIMENSION [MM] AxBxC
1500
135x20,5x19
3000
140x28,5x27
1500
175x27x25
4000
240x37x35
LIGHT SOURCE CONFIGURATION CODE
POWER
LUMEN OUTPUT
LS01
3W
126 - 165 lm/W
LS02
3W
100 - 140 lm/W
LS03
3W
140 - 180 lm/W
34,5
19
MOUNTING HOLES (mm):
34,5
123,5
LS01
BMA / BM
28,7
120 LS02 / LS03
Legend: Li - battery LiFePO4 CD - battery NiCD BMA - conversion kit UNILED BMA BM - conversion kit UNILED BM LS01 - light source power LED LS02 - light source LED SMD LS03 - light source high efficiency LED SMD PT – manual test button AT – autotest
107
systems RUBIC MINI UNA
110
RUBIC UNA RUBIC UNA WIRELESS DYNAMIC ESCAPE SYSTEM DES FIRE ALARM SYSTEM FAS
111 112 114 116
CENTRAL BATTERY SYSTEM FZLV
118
CENTRAL BATTERY SYSTEM SPS
120
CENTRAL BATTERY SYSTEM LPS
122
CENTRAL BATTERY SYSTEM CBS
124
THE SMART VISIO PLATFORM
126
RUBIC MINI UNA
CENTRAL BATTERY SYSTEM CBS
RUBIC UNA
SMART VISIO PLATFORM
RUBIC UNA WIRELESS
DYNAMIC ESCAPE SYSTEM DES
FIRE ALARM SYSTEM FAS
CENTRAL BATTERY SYSTEM FZLV
CENTRAL BATTERY SYSTEM LPS
systems RUBIC MINI UNA Key features:
The RUBIC MINI UNA system is a modern, compact solution designed for the monitoring of emergency luminaires with unique addresses installed in small-size buildings and facilities. The system offers the possibility to supervise up to 500 emergency luminaires equipped with RUtype power supply sources. The main advantages of the MINI UNA control unit are its compact size and the possibility to mount it on a DIN-3 standard rail (TH35). The system is simplified but not deprived of the most important functionalities from the user’s point of view. Each control unit is equipped with an RS485 connection for the communication bus, an RJ45 connector, four LEDs indicating the current status of the system, three function keys which can be programmed in the control unit, a reset button and a service pin to assign a unique IP address to the unit. Additionally, the control unit has two potential-free input contacts and two voltage outputs (so-called ‘open collector’). Communication with RU emergency luminaires is provided by means of an RS485 standard communication bus. A single bus may not exceed 1200 m when linear topology is used. The communication with luminaires is continuous.
• Monitoring of up to 500 emergency luminaires • Maximum length of a single bus is 1200 m • System status LEDs • TH35 (DIN-3) rail mounted • Three programmable function keys • Two potential-free inputs (current loops) • Two voltage outputs (to control external relays) • Internal memory to store emergency lighting system reports, compliant with PN-EN 50172 • Mains supply mode, configured from the control unit • Testing of individual luminaires or groups of luminaires • Built-in battery to provide back-up power supply to the control unit • RJ45 connector for direct communication with any computer via Ethernet • Individually programmable IP address • System status preview using any web browser • Continuous communication with luminaires installed in the system • System management and visualization by means of dedicated SMART VISIO software
RS485 max. 1200m
01.001
01.002
01.003
01.099
01.100
00–0A–139A–F001
00–0B–C21A–0020
00–01–1A1F–F001
00–00–1C2C–F001
00–01–1A0D–F0FF
RS485 max. 1200m
RUBIC MINI UNA
02.001
02.033
02.123
02.240
00–0A–132A–F091
00–0A–141A–9000
00–00–122C–F901
00–00–122C–F001
LAN max. 100m
ROUTER INTERNET LAN max. 100m
PC
110
PC
WWW
max. 500 units
systems RUBIC UNA Each RU address module is assigned an individual number/address. The addresses are factory-assigned, so an addressing unit is not required for installation, setting up or maintenance work. Key features:
The RUBIC UNA is the latest and the most advanced monitoring system designed to control independent luminaires of emergency and escape route lighting systems. It is designed to be used in medium-to-large facilities and buildings. Each control unit can handle up to 4000 luminaires using MPU250 Power submodules. The submodules communicate with the RUBIC UNA control unit via LAN. The use of LAN also enables communication between individual submodules. The RUBIC UNA system is equipped with a touch panel and an intuitive graphic menu to enable quick and easy system configuration without the need for using SMART VISIO.
• Touch screen control unit • Unique addresses of luminaires • Factory-assigned module addresses • No need for an addressing unit • Intuitive GUI • No need to observe the polarity of communication cables • Four built-in potential-free contacts (input and output) • Remote control option via Ethernet and a dedicated website • Monitoring of up to 750 luminaires per control unit (3 logical buses: 01, 02 and 03 – each one with 2 physical channels) • Possibility to expand the control system to 4000 luminaires using submodules • System status indication by means of icons on the control unit screen • Compatibility with fluorescent and LED light sources • Internal battery enabling continuous operation of the control unit • Automatic performance of tests • Registration of test results in an event log • Division of luminaires into groups with freely adjustable testing times • Mains supply mode for selected luminaires/groups • System management and visualization by means of dedicated SMART VISIO software • BACnet standard, enabling compatibility of the RUBIC UNA with Building Management Systems (BMS) SMART VISIO
Thanks to introduced technical solutions polarity does not need to be observed any more while connecting a communication bus to the following system components: • RUBIC UNA control unit • MPU250 Power submodules • RU address modules
RS485 max. 1200m
RS485
06.001
06.002
06.003
06.091
00–0A–2A3A–F001
00–1A–1F1A–0001
00–00–1F1D–F001
00–10–1F2C–F021
max. 1200m
MPU250 - POWER
05.001
05.002
05.007
05.211
00–0A–214C–F001
00–1A–141C–0120
00–00–113F–C201
00–10–12CC–F321
Max 250 units
RS485 max. 1200m
MPU250 - POWER LAN max. 100m
LAN
RUBIC UNA
04.001
04.043
04.123
04.240
00–2A–231A–F022
00–1A–131A–0143
00–00–311D–F029
00–10–322C–F028
Max 250 units
RS485 max. 1200m
max. 100m
ROUTER
RS485
03.001
03.003
03.031
00–1A–145A–0143
00–00–115D–F029
00–10–126C–F027
max. 1200m
RS485
Max 750 units
02.001
02.033
02.123
00–1A–144A–0143
00–00–141D–F029
00–10–142C–F023
max. 1200m
INTERNET
PC
111
WWW
01.001
01.010
01.123
00–1A–121A–0143
00–00–121D–F029
00–10–132C–F023
Max 4000 units
systems RUBIC UNA WIRELESS RUBIC UNA Wireless system is the latest and most advanced version of the monitoring system intended for emergency and evacuation luminaires. It is dedicated to medium-sized and large facilities. Each central unit can control up to 4000 luminaires with the use of subordinate modules MPW250 – Power. Subordinate modules communicate with RUBIC UNA RW central unit via LAN network. Communication between luminaires and central unit is wireless. The use of Mesh network and innovative data sending algorithms has allowed to have a range of 200m in the open space. The system operates in the band ISM 868 MHz which allows overcoming such obstacles as a concrete ceiling and walls. Thanks to the band, it is possible to increase the range fourfold when compared to devices operating in the band 2,4GHz, e.g. Wi-Fi standard access points. Key features: • Central unit with a touch panel • Unique luminaire addresses • Modules addressed during manufacturing • Address programmer not required • Intuitive graphic menu • Communication in band ISM 868MHz • Range up to 200m in open space • Possible to use signal booster • 4 potential-free inputs and outputs built in the central unit • Possible to have remote control via Ethernet and website • The central unit monitors up to 250 wireless luminaires • Possible to extend to have 4000 luminaires thanks to the use of subordinate modules • Possible to connect Wireless luminaires and cable luminaires • System status signaling via icons on the central unit screen • Possible to connect LED sources of light • Internal storage battery for continuous operation of the central unit • Automatic tests • Recording test results in event log • Possible to divide luminaires into groups with any testing time • Network operation mode for selected luminaires/groups • System management and presentation by means of dedicated SmartVISIO software • BACnet system assuring compatibility of RUBIC UNA RW with BMS system
MPW250 POWER
230V
230V
230V
230V
230V
230V
230V
230V
230V
230V
230V
230V
230V
230V
230V
230V
230V
230V
230V
230V
RS485 max. 1200m
MPU250 POWER
LAN max. 100m
LAN max. 100m
ROUTER
INTERNET
112
RUBIC UNA WIRELESS
PC
WWW
systems RUBIC UNA RW central unit has a built-in additional subordinate module with aerial intended to communicate with wireless luminaires. Every emergency and evacuation luminaire must have a built-in aerial to communicate wirelessly. The aerial is located in a way that excludes a risk of additional interference arising from operation of electronics. RUBIC UNA Wireless has a touch panel and intuitive graphic menu so that you can easily configure the system without using SmartVISIO application. Every RW address module has its own individual number/address. Addresses are assigned during manufacturing so it is not necessary to provide any additional address programmer for installation and aintenance.
SYSTEM ELEMENTS MODULE MPW250 – POWER Key features: • Assembly of subordinate module on bus DIN-3 (TH35) • Monitoring up to 250 luminaires • Connection to Ethernet – communication via LAN • "Service pin" key and Reset • Possible to set IP address on one's own • Built-in wireless feeder • Built-in storage battery charging LED
ADDRESS MODULE WIRELESS Key features: • Cooperation with LED source of light • Emergency mode switch • Compatible with storage batteries Ni-Cd or LiFePO4 • Storage battery charging signal • Luminaire status signal • Compatible with specific Wireless luminaires
SIGNAL BOOSTER WIRELESS Key features: • Cooperation with Wireless luminaires • Compatible with storage batteries Ni-Cd or LiFePO4 • Booster status signal • Status signal related to communication with RUBIC central unit
SMART VISIO APPLICATION Key features: • System status control • System programming • Event log readout and printout • Calling test function • Possible to read in plans
113
73
systems DYNAMIC ESCAPE SYSTEM Dynamic illumination is an innovative system controlling escape route depanding on situation present on facility. Due to connection with fire alarm systems, marking allows to fast recognition of safe escape route. Rapidally changing conditions such as smoke or fire require system which allows fast and dynamic change of the safest escape route. The DES system cooperates with the CBS central battery system. Due to such solution dynamic luminaires are also powered during malfunction. Circuits which power dynamic luminaires should be led with fire resistant 3 core cable. Comunication between the dynamic luminaires and the control panel is done with the 3 core communication cable. The DES panel sends information about active scenario to particular luminaires. There is also possibility to check automatically and completely if the installed luminaires work properly. The test result is registered in a log file which is saved in non-volatile memory.
MWB MODULE
RS485
max. 1200m
POTENTIAL FREE FIRE ALARM SYSTEM SIGNAL
SMART VISIO
DES PANEL
VIZUALIZATION
LAN max. 100m
CENTRAL BATTERY SYSTEM CBS
POTENTIAL FREE TEST SIGNAL
COMMUNICATION
HDGS 3x2,5mm2
POWER SUPPLY 230 VAC/216 VDC
114
systems
Dynamic luminaires may display up to 10 characters depanding on accepted scenerio. Additional function is running light mode. Scenarios are initiated from panel on DES control unit and potential-free MWB input module which gathers signals from detection devices. Any time scenario changes maybe done without any additional software.
MP 4
Max 250 luminaire
MP 16
MPU 250 power Max 13
Max 250 luminaire
Max 250 luminaire
Max 250 luminaire
Max 750
Max 250 luminaire
115
systems FIRE ALARM SYSTEM FAS The FAS fire alarm system is an element of building security. The FAS is intended for detecting fire in the early phase. Modular construction allows to wide extension and because of this to control large-size buildings. The main element of the system is central unit, which is responsible for receiving signals from devices located on detection circuits and transferring to other executive devices co-creating the fire protection system of the building. Fire detectors are automatic detection elements. They are equipped with heat or smoke detectors. Manual call points are intended for transmitting information about the fire to the person who will notice it and manually activate the device. Input/Output modules are designed to cooperation with external fire protection devices or systems, while signaling devices are used to alert people in the building about unsafe conditions.
Key features: • Conformity with EN 54-2, EN 54-4 standard • Up to 250 elements per a loop • Up to 250 supervisory zones per loop • Outputs built-in: • ATS • Signal lines • Fault • Universal relay • Maximum loop length 2000m • Loop interval detection • Events counter up to 15,000 • Expansion cards • Up to 7 supervisory loops • 7-Inch touch screen • Printer built-in • BACnet, www interface
ROUTER NETWORK
BMS BUILDING MANAGEMENT SYSTEM
116
PC
systems FAS SYSTEM ELEMENTS/COMPONENTS EXTERNAL SIGNAL PANEL ESP Key features: • Double interface of the control unit • 7-Inch touch screen • 4 levels of access • Multi-language service • Access blockade by using a key • Compact casing
FIRE DETECTORS Key features: • Conformity with EN 54-5 and 54-7 standard • Regulation of alarm threshold which compensates the influence of the environment • Indication of an alarm by means of the LED diode • Additional LED diodes for the testing state • Integrated short-circuit isolator • A casing with a low profile • Detection of test fire: from TF1 to TF9
MANUAL CALL POINT Key features: • Conformity with EN 54-11 standard • Double-sided short-circuit isolator built-in • The manual call point type A • Supervision state possible to be restored • Operation in the addressable systems • Signalling diode
INPUT/OUTPUT MODULES Key features: • Conformity with EN 54-18 standard • Cooperate between fire-fighting devices and the AWEX FAS • MIO modules are equipped with relay no monitored outputs • MIO modules are equipped with relay monitored outputs • MIO modules are equipped with potencial outputs for signaling devices • MIO modules are equipped with free potencial inputs • MIO modules are equipped with potencial inputs • Integrated short-circuit isolator which allows quickly location of fault • Two IP Rating casing type: IP66 or IP67
SIGNALLING DEVICE Key features: • Conformity with EN 54-3 and 54-23 standard • Small dimensions • LED signalling diodes • Low consumption of current • 4 or 16 sound patterns • Adjusting the volume
117
73
systems CENTRAL BATTERY SYSTEM FZLV Central battery system FZLV is a high-tech device created to power and monitor emergency lighting in buildings of small and medium size and in closed fire zones. The system can work with up to 80 LED luminaires supplied by SELV 24V (Safety Extra-Low Voltage) and was designed in SMART technology. The application of the SELV voltage ensures high level of safety of servicing of the system and its elements are compilant with the currently valid regulations. Small dimensions of the central unit enable the installation of the system in places where one cannot fit a large-size central battery system. The FZLV central unit is equipped with a big touch panel enabling both the current reading of the status of the system, circuits and
FZLV - 12 Ah
fittings and the introduction of all settings and parameters of the system with the use of the user interface. Statuses are displayed in both graphic and text form. Using the central unit one can assign a name to the fitting that will clearly help to identify the fittings installed in the system. Using the central unit one can program and freely configure the emergency fittings in constant, non-constant, switching and switching-dimming modes as well as night work mode. The system has its own IP address and RJ45 slot which is used for direct connection to Ethernet. With an built-in WEB module you can directly access the system from any computer and print the event log by using any web browser. Additionally, the system has an input and an SD card that allows to record and upload system settings (back-up) and the record of the reports of the Event Log in accordance with EN 50172.
FZLV - 24 Ah
FZLV - MAX 33/52 Ah
1....20
1....20
1....20
1....20
FIRE ZONE
FIRE ZONE
1....20
1....20
1....20
1....20
FIRE ZONE
FIRE ZONE
1....20
1....20
1....20
1....20 PH90*
STAIRS
118
FIRE ZONE
FIRE ZONE
systems Key features: • Power supply and monitoring up to 80 individual LED fittings in SMART technology • Safe supply SELV 24V • SMART technology – any mode of a fitting • Easy to read, big LCD touch screen • Easy and intuitive menu with simple icons • Automated testing • Automatic detection and adding of the fittings to the system • Built-in WEB module • Programming and configuration of the fittings directly from the system • Communication with luminaires through the power supply cable • SD slot and SD card for recording, transmission and printing emergency lighting reports from any PC, in accordance with EN 50172
SMART VISIO
• Possibility to store the system settings (back – up) on SD card • Contained security light mode (night operation) • Possibility to control fittings and some functions of the system via terminals 24V and 230V • Testing of each fitting separately as well as group of fittings • Internal rechargeable battery with a designed life of 10 years • RJ45 slot for direct connection to Ethernet • Individual IP address • Preview of the system via any web browser • Works with any BMS (Building Management System) by using the module of potential-free contacts or a ModBus • Unlimited grouping of systems and joint supervision by Smart Touch Controller • Programmable emergency time operation for individual fixtures
SMART VISIO
WEB
ACCESS POINT INTERNET ROUTER
MAX 100m MAX 100m
MAX 100m
1....20
MAX 100m MAX 100m MAX 100m
MAX 100m
1....20
1....20
1....20
FIRE ZONE
FIRE ZONE
1....20
1....20
1....20
1....20
FIRE ZONE
FIRE ZONE
1....20
1....20
1....20
1....20 PH90*
STAIRS
119
FIRE ZONE
FIRE ZONE
systems CENTRAL BATTERY SYSTEM SPS The Central Battery System SPS provides emergency power supply when the mains power is lost or its parameters are inappropriate. The main purpose of the system is to supply power to emergency lighting luminaires and assure 100% of the power for at least 1 hour. The lighting which uses LED luminaires, fluorescent luminaires or compact fluorescent luminaires can combine them in the same system. It is possible to connect any type of luminaire and it is not necessary to install any additional internal module. When designing the device, all applicable standards were followed. The device is composed of an inverter which serves to maintain the voltage of 230 VAC ± 3 % 50 Hz on output circuits. The system is equipped with batteries whose capacity is dependent upon load and emergency luminaire supply period.
SPS 300
SPS 600
SPS 1000
The batteries are self-operating accumulators with a 10-year operation life. SPS is based on the Offline technology, connected devices are supplied directly from the mains. The supply voltage is regularly monitored and in the event of a loss, the control system (after ca. 150 ms) disconnects the mains power and switches into accumulator mode. The device is secured against extensive load and short circuit. The circuit safety devices are continuously monitored and the damage notification is displayed on the front signaling panel. In spite of the simple structure, SPS has been provided with a set of modern functions. The unit can be configured and operated by means of the built-in www server and SmartVisio app (optional). The use of all-purpose Modbus and BACnet protocols allows integrating system from BMS. A small size of the cabinet allows installing the system in places where large-size central battery systems do not fit.
SPS 1500
SPS 2000
max 250 W
max 250 W
max 250 W
max 250 W
max 250 W
max 250 W
FIRE ZONE
FIRE ZONE
max 250 W
max 250 W
max 250 W
max 250 W
FIRE ZONE
STAIRCASE
max 250 W
max 250 W
max 250 W
max 250 W PH90*
FIRE ZONE
120
FIRE ZONE
FIRE ZONE
systems OFFLINE TECHNOLOGY – IF NEEDED The Central Battery System SPS is based on the Offline technology. Thanks to this technology, it is possible to minimize energy losses during mains operation and thus increase durability and reduce operation costs. In practice, it is possible to supply devices connected to SPS directly from the mains. During a normal mains operation, the system control unit and a unit responsible for monitoring accumulator parameters are supplied with power. The supply voltage is monitored on a regular basis and in case of its loss (after about 150ms) the converter starts operating and converts the constant voltage of 24 VDC from accumulators into alternating voltage for output (230 VAC 50 Hz sinus). Advantages OFFLINE: • Inconsiderable energy losses during mains power operation • low working temperature • increased system component durability • low operation costs due to low damage rate • low noise emission during mains operation
The diagram of the emergency supply central system SPS.
121
systems CENTRAL BATTERY SYSTEM LPS The LPS is a state-of-the-art, reliable and user-friendly central battery system manufactured by AWEX. It has been designed to meet applicable standards and comprises the proprietary SMART technology. From the functional point of view, the LPS is equivalent to the CBS, however due to its compact size and reduced power output it is intended for smaller-sized locations or in places where the power sources of emergency luminaires must be diversified (as a group). The LPS can power luminaires with a total power output of 1500W for 1h or 500W for 3h. Thanks to four sensor
inputs provided in the control module, fire zones can be managed by means of phase loss sensors (CZF) which monitor the voltage of the power supplied to the zones, The system is upgradable with ELS230 modules with 9 potential control inputs. Line modules have separate protection for AC and DC mode, which considerably increases the safety of emergency lighting activation in the building/facility. In the DC mode, the system operates as an IT network (insulated).
System LPS
122
systems Key features: • Possibility to record the back-up of the system on the SD card • Night mode operation • Possibility to control luminaires and functions of the system through the 24V and 230V internal and external connectors • Possibility to monitor power in the distribution boards and in the separate lighting circuits • RJ45 connector for direct communication with any computer via Ethernet • Preview of the system via any web browser • Management and visualization of the system by using dedicated software SMART VISIO • Supply of the fixtures of total capacity 1500W for time 1h or 500W for 3h
SUPPLY
LON/LAN
LON/LAN
LON/LAN
• LCD display with easy-to-use menu • Automatic test performing • Automatic detection and adding luminaires to the system • Monitoring of each luminaire • Monitoring of each circuit • Programming and configuration of the luminaires directly from the central unit • Communication with luminaires through the power cable • SMART technology – any mode of operation of the luminaire • The linear modules are secured for the AC and DC mode separatelly • SD card slot and card itself allow to save the periodic test results, event log and system configuration
123
systems CENTRAL BATTERY SYSTEM CBS The CBS central battery system is state-of-the-art, reliable and easyto-operate central battery system constructed in accordance with the requirements of VDE 0108 as well as EN 50171 and EN 50172 standards. Due to the possibility of using sub-modules it is dedicated to medium and large buildings and was designed in SMART technology. The system monitors each output circuit individually and with the use of address modules – each luminaire. The system allows any configuration of mode both of the circuit and the luminaire. Using the driver one can programme the mode of the address module without interfering into the luminaire and without any specialized service software. The SD card slot used in the system allows to perform a backup of the system and to save
the periodic test results, event log and system configuration, in accordance with EN 50172. The event log can be printed out of the SD card on any PC without any additional software. Besides, all the settings are stored in non-volatile memory and will not be lost even during the complete power supply and battery failure. The charger module ensures battery charging based on UI characteristics with temperature compensation according to EN 50171. The charger is equipped with internal active PFC module which provides a power factor close to 1. Linear modules have separate protection for AC and DC mode, significantly increasing the safety level while switching on emergency lighting in the building. In DC mode the system works in IT network layout (isolated system).
System CBS Compact
System CBS Standard
124
systems Key features: • LCD display with easy-to-use menu • Automatic test performing • Automatic detection and adding luminaires to the system • Monitoring of each luminaire • Monitoring of each circuit • Programming and configuration of the luminaires directly from the central unit • Communication with luminaires through the power cable • SMART technology – any mode of operation of the luminaire • The linear modules are secured for the AC and DC mode separatelly • SD card slot and card itself allow to save the periodic test results, event log and system configuration, • Possibility to record the back-up of the system on the SD card
• Night mode operation • Possibility to control luminaires and functions of the system through the 24V and 230V internal and external connectors • Possibility to monitor power in the distribution boards and in the separate lighting circuits • Possibility to use sub-modules in standard version and HUB version • RJ45 connector for direct communication with any computer via Ethernet • Preview of the system via any web browser • Battery set with 10 years life-time • Works with any BMS (Building Management System) by using the potential-free contacts or BacNet • Management, supervision and visualization of entire system via dedicated SMART VISIO software
Central battery circuits CB/02 circuit control signal
Central battery substation circuits L=230V
CB/02 CIRCUIT MONITORING
CB/02 (n=MAX 20 or 6A)
CB/01/01
CB/01/02
CB/01/03
CB/01/n (n=MAX 20)
PBS/01/n (n=MAX 20)
PBS/01/03
PBS/01/02
PBS/01/01
PBS/02/n (n=MAX 20)
PBS/02/03
PBS/02/02
PBS/02/01
CB/01 LUMINAIRE monitoring (mixed mode) PBS/02 – LUMINAIRE monitoring
AC - 230V LON LON
PBS/01 – LUMINAIRE monitoring (mixed mode)
DC - 216V LAN
AC - 230V
230V MAINS
ELS-230 module
Phase loss sensor CZF LON
PBS
Phase loss sensor
BMS
MONITORING OF L1, L2, L3 230V
125
CBS
MONITORING OF L1, L2, L3 230V
Remote status panel PZS LON
SMART VISIO
MONITORING OF L1, L2, L3 230V
systems THE SMART VISIO PLATFORM SMART VISO is an advanced control and monitoring application for the latest emergency lighting systems manufactured by AWEX. Irrespective of the chosen solution SMART VISIO enables connection, integration and visualization of each system at the same time in any configuration and at a single control desk. Thanks to the application of the common BACnet protocol for system communication, the software can be implemented virtually in any building. SMART VISIO is inexpensive
to install and offers the possibility of complete system visualization, which saves time and costs of everyday supervision. The software is recommended for use in shopping centres, medium and large office buildings, hospitals, stadiums, airport terminals, manufacturing plants and special purpose facilities. The system reporting complies with PN-EN 50172.
Key features:
• Possibility of installation on any Windows-based PC connected to a common LAN • Instant verification of any faults and system errors • Quick identification of faulty devices • Simple diagnostics of primary system parameters visualized in a block diagram • Possibility of system expansion by any number of connected components • Possibility of remote management of integrated systems
• Compatibility with all other AWEX emergency lighting systems • Intuitive menu • Possibility to upload floor plans and luminaire layouts • Automatic control of emergency lighting • Unlimited configuration possibilities for individual luminaires and the whole system from one place • Luminaire and system status monitoring
SMART VISIO APPLICATION
PC
LAN
LAN
max. 100m
max. 100m
SWITCH
CBS
126
LPS
SPS
FZLV
RUBIC UNA / RUBIC UNA WIRELESS
systems The structure of the system is represented as a tree and as panels with tabs. The order of elements is not set manually by a user, but is a result of addressing. The number and contents of tabs depend on the element of the system currently selected. Each element has a tab that displays its status. In the tree of the system, one of the systems can be selected and its status will be shown on the panel. If the System is chosen, the status of all the central units will be seen (icons change color the same way as on the plan of the building). To change the current settings, use “Settings� tab.
RUBIC panel allows you to see the status of Rubic UNA or Rubic UNA MINI central unit, as well as conversion kits and luminaires connected to it, to see the results of tests, reports and configuration of the central unit. The diagram displays the software version, serial number, status of inputs, outputs, errors, lock, night work, power status, charger status, battery status. Icons indicate the status of groups and sub-modules.
FZLV panel allows observation of the FZLV central unit and the luminaires connected to it, viewing test results, reports, graphs and configuration of the central unit. The diagram shows the hardware and software version, serial number, status of inputs, outputs, errors, lock, night work, total status of the central unit, power status, charger status, battery status, circuit status.
CBS panel allows observation of status of the central battery, control unit, charger, sensor modules, linear modules and luminaires, view test results, reports. The diagram shows a view of the central battery cabinet. Modules inside the cabinet can be moved by dragging the module with a mouse, left button pressed. The control module is shown as CM (Control Module), charger is shown as CH (Charger). The status of the groups (G1 – G255) is displayed in the table named Steering Groups. The list displays the status of the linear modules LM (Linear Module) and sensor modules SM (Sensor Module).
127
additional components HTR 25 - HEATER WITH THERMOSTAT
130
FOR LOW TEMPERATURE BATTERIES
131
ACCESSORIES
132
PICTOGRAMS
134
HTR 25 HEATER WITH THERMOSTAT
BATTERIES
ACCESSORIES
PICTOGRAMS
additional components HTR 25 - HEATER WITH THERMOSTAT FOR LOW TEMPERATURE System HTR-25 allows our emergency lighting fixtures to work in up to -25°C, which makes our products suitable for installation in cold rooms, parkings and outside of the buildings where self-contained emergency lighting fixtures are exposed to low temperatures. This innovative solution can be used with both NiCd and Ni-MH battery packs, with fluorescent tubes and with LED’s. HTR-25 is suitable for AWEX’s IP65 fixtures and for our conversion kits assembled in IP65 commercial lighting. TECHNICAL SPECIFICATION: Power supply: 230 VAC/50 Hz Insulation class: I Minimal ambient temperature: -25°C Minimal battery temperature: +6°C Heater initiation temperature: <10°C
1
4 2
L N PE
3
Legend: 1. Thermostat NO – closing temperature 10°C ±5°C – assembled inside the fixture 2. Thermostat NC – opening temperature 60°C ± 5°C – assembled on the battery 3. Self-regulated heating wire 4. Battery pack
ORDER CODES CODE
BATTERY CAPACITY
HTR-25/6.4-1000-Li
6.4V 1000mAh
BATTERY TYPE LiFePO4
HTR-25/6.4-1500-Li
6.4V 1500mAh
LiFePO4
HTR-25/6.4-3000-Li
6.4V 3000mAh
LiFePO4
HTR-25/9.6-1500-Li
9.6V 1500mAh
LiFePO4
CODE
BATTERY CAPACITY
BATTERY TYPE
CODE
BATTERY CAPACITY
HTR-25/3.6-1000-CD
3.6V 1000mAh
Ni-Cd
HTR-25/3.6-1000-MH
3.6V 1000mAh
BATTERY TYPE Ni-MH
HTR-25/3.6-1500-CD
3.6V 1500mAh
Ni-Cd
HTR-25/3.6-1500-MH
3.6V 1500mAh
Ni-MH
HTR-25/3.6-2500-CD
3.6V 2500mAh
Ni-Cd
HTR-25/3.6-2500-MH
3.6V 2500mAh
Ni-MH
HTR-25/3.6-4000-CD
3.6V 4000mAh
Ni-Cd
HTR-25/3.6-4000-MH
3.6V 4000mAh
Ni-MH
HTR-25/4.8-1500-CD
4.8V 1500mAh
Ni-Cd
HTR-25/4.8-1500-MH
4.8V 1500mAh
Ni-MH
HTR-25/4.8-2500-CD
4.8V 2500mAh
Ni-Cd
HTR-25/4.8-2500-MH
4.8V 2500mAh
Ni-MH
HTR-25/4.8-4000-CD
4.8V 4000mAh
Ni-Cd
HTR-25/4.8-4000-MH
4.8V 4000mAh
Ni-MH
HTR-25/6.0-1500-CD
6.0V 1500mAh
Ni-Cd
HTR-25/6.0-1500-MH
6.0V 1500mAh
Ni-MH
HTR-25/6.0-2500-CD
6.0V 2500mAh
Ni-Cd
HTR-25/6.0-2500-MH
6.0V 2500mAh
Ni-MH
HTR-25/6.0-4000-CD
6.0V 4000mAh
Ni-Cd
HTR-25/6.0-4000-MH
6.0V 4000mAh
Ni-MH
HTR 25 heating system type is designed for installation in luminaires with a degree of IP65 or higher.
130
additional components BATTERIES
CODE
Ni-Cd
Ni-Cd
Ni-Cd
Ni-MH
Ni-MH
DIMENSIONS [mm] AxBxCxDxExF
WEIGHT [Kg]
1000
153x179x18x15x14x4
0,076
1500
136x162x25x22x18x4
0,14
152x178x30x26x20x4
0,21
4000
189x210x30x33x25x4
0,352
1500
175x202x25x22x18x4
0,184
202x228x30x26x20x4
0,288
4000
245x270x36x33x25x4
0,452
1500
218x244x25x22x18x4
0,228
248x275x30x26x20x4
0,354
4000
303x329x36x33x25x4
0,574
1500
153x179x18x15x14x4
0,088
136x162x25xx22x18x4
0,172
CAPACITY [mAh]
2500
2500
2500
2500
VOLTAGE [V]
3.6
4.8
6.0
3.6
4000
152x179x30x26x20x4
0,26
1500
202x228x18x15x14x4
0,114
2500
4.8
4000 1500 Ni-MH
175x202x25x22x18x4
0,22
202x228x30x26x20x4
0,338
251x276x18x15x14x4
0,14
220x246x26x23x18x4
0,268
4000
251x276x30x26x20x4
0,398
1000
105x135x31x19x20x4
0,09
135x165x31x19x20x4
0,112
140x170x31x27x20x4
0,197
203x233x31x19x20x4
0,152
2500
LiFePO4
1500
LiFePO4
1500
6.0
6.4
3000 9.6
F
E
D
C
A B
131
additional components ACCESSORIES PICTURE
TECHNICAL DRAWING
C
A
HELIOS, EXIT S, EXIT M, EXIT L Dimensions (mm): (AxBxC): Helios: 300x128x30 EXIT S: 202x121x26 EXIT M: 250x142x33 EXIT L: 300x172x33
B
CEILING BRACKET CODE: 1902 – HELIOS 1903 – EXIT S 1904 – EXIT M 1905 – EXIT L
APPLICATION
A
C
HELIOS, EXIT S, EXIT M, EXIT L Dimensions (mm): (AxBxC): Helios: 300x128x30 EXIT S: 202x121x26 EXIT M: 250x142x33 EXIT L: 300x172x33
B
WALL BRACKET CODE: 1901 – HELIOS 1906 – EXIT S 1907 – EXIT M 1908 – EXIT L
B
CEILING BRACKET WITH PIPE CODE: 2944 – HELIOS 2945 – EXIT S 2946 – EXIT M 2947 – EXIT L
HELIOS, EXIT S, EXIT M, EXIT L Dimensions (mm): (AxBxC): Helios: 300x128x435 EXIT S: 202x121x428 EXIT M: 250x142x449 EXIT L: 300x172x479
C
NAME/CODE
A 35
57
ADJUSTABLE HANDLE 0-90° CODE: 3001
EXIT M, EXIT L
47
325 WALL BRACKET 90° CODE: 1009
120
TWINS
120
SUSPENSION ROPES CODE: 1006
SCREEN DS, TWINS, ARROW
WIRE GUARD CODE: 1003 – HELIOS 1012 – EXIT S 1013 – EXIT M 1014 – EXIT L
37
HELIOS, EXIT S, EXIT M, EXIT L Dimensions (mm): (AxBxC): Helios: 405x100x170 EXIT S: 250x55x147 EXIT M: 310x55x197 EXIT L: 410x80x205
100
ACCESORY FOR RECESSED MOUNTING CODE: IF2/REC
INFINITY II
268
CONCRETE BOX CODE: IF2/RWC
77
41,5
INFINITY II
256
132
additional components
NAME/CODE
PICTURE
TECHNICAL DRAWING
APPLICATION
37
232
UM BOX CODE: UM/BOX
72
UNILED UM
75
ACCESORY FOR RECESSED MOUNTING CODE: SK8/REC
344
SK-8
370
ACCESORY FOR RECESSED MOUNTING (SET) CODE: ETS/REC – EXIT S ETE/REC – EXIT M ETL/REC – EXIT L
C
EXIT S, EXIT M, EXIT L
30
B
Dimensions:(AxBxC): EXIT S: 36x36x1,5 EXIT M: 42x31x1,5 EXIT L: 37x34x1,5
15
ACCESORY FOR PENDANT MOUNTING CODE: ETE/PEN
A
1,50
EXIT S, EXIT M, EXIT L
1000
300
EXIT M
130
PLEXI GLASS (SET) CODE: ETE/PLX
8
A
B
PLEXI GLASS (SET) CODE: ETS/PLX - EXIT S ETL/PLX - EXIT L
C
40
TRACK LIGHTING INSTALLATION ACCESSORY (SET) CODE: ARN/EUT
300
39
320
133
ARROW N
90
320
ACCESORY FOR RECESSED MOUNTING (SET) CODE: EDGS/REC
EXIT S, EXIT L Dimensions:(AxBxC): EXIT S: 224x107x6 EXIT L: 330x155x8
EDGE S
additional components PICTOGRAMS – STICKERS Pictograms (compliant with PN-EN ISO 7010:2012)
22
23
24
25
26
27
61
29
Additional pictograms
28 CODE
PSxx
PNxx
PMxx
PBxx
PVxx
PWxx
Dimensions [mm]
100x300
100x200
125x250
150x300
200x400
300x600
Compatible with:
TL, TG, TGS, TLS
ETS
ETE, HL, HEL, HDL, HDEL, ARN, ARP
TW, IF2, SK8, ETL, EL
SC40, SCS40
SC60, SCS60
Legend: xx – pictogram ID number (see the photos above) Versatile pictogram sets (compliant with PN-EN ISO 7010:2012)
34 31
32
33 CODE
PU31
PU32
PU33
PU34
Dimensions [mm]
125x250 (125x375)*
150x300 (150x450)*
100x300 (150x600)*
100x200 (100x300)*
Compatible with:
ETE, HEL, HL, HDL, HDEL, ARN, ARP
TW, IF2, SK8, ETL, EL
TL, TG, TGS, TLS
ETS
*overall size
Arrow signs (compliant with PN-EN ISO 7010:2012)
41
42
43
44
47
48
CODE
PU41, PU42
PU43, PU44
PU47, PU48
Dimensions [mm]
125x125
150x150
100x100
Compatible with:
ETE, HL, HEL, HDL, HDEL, ARN, ARP
TW, IF2, SK8, ETL
ETS
134
additional components PICTOGRAMS – FOIL Compliant with PN-EN ISO 7010:2012 CODE
PSxxF
PDxxF
PLxxF
Dimensions [mm]
125x250
150x300
150x300
Compatible with:
ARN, ARP
IF2, IK, IKP
ETL
PICTOGRAMS – PAINTED ON PLEXI Compliant with PN-EN ISO 7010:2012 CODE
PDxxyy
Dimensions [mm]
100x200
Compatible with:
ETS/PLX
125x250
Legend: xx- pictogram ID number (see the photos of Pictograms - Stickers) yy - luminary code
135
150x300
ETE/PLX, HL, HEL, HDL, HDEL, ARN, ARP PL, TW, IF2, SK8, ETL/PLX, SC30, SCS30, EL
200x400
300x600
SC40, SCS40
SC60, SCS60
Information for readers PHOTOMETRY USED SYMBOLS
PHOTOMETRY
USED SYMBOLS
138 165
Information for readers Photometry of EXIT S – ETS, ETSR, ETSU
L1
L2
h
L1 – distance from the wall to the first fixture L2 – distance between fixtures h – height of the ceiling
ETS – LED 1W, 2W, 3W
ETSR – LED 1W, 2W, 3W
ETSU – LED 1W, 2W, 3W
ETS 1W (130lm) min. 0,5lx
ETS 2W (265lm) min. 0,5lx
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
3,0
8,0
2,50
3,5
10,0
2,50
4,0
11,0
3,00
3,5
9,0
3,00
4,0
10,5
3,00
4,0
12,0
3,50
4,0
10,0
3,50
4,0
11,5
3,50
4,5
13,0
4,00
3,5
10,5
4,00
4,5
13,0
4,00
4,5
14,0
4,50
3,5
11,0
4,50
4,5
14,0
4,50
5,0
14,5
5,00
3,5
12,0
5,00
4,5
14,0
5,00
5,0
15,5
6,00
3,5
12,5
6,00
4,5
15,0
6,00
5,5
16,5
7,00
3,5
12,0
7,00
4,5
16,0
7,00
5,5
18,0
8,00
3,5
12,5
8,00
4,0
16,0
8,00
5,0
19,0
ETSR 1W (130lm) min. 1lx
ETSR 2W (265lm) min. 1lx
ETSR 3W (360lm) min. 1lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
5,5
12,5
2,50
6,5
15,0
2,50
7,0
16,5
3,00
6,0
14,5
3,00
7,0
16,5
3,00
7,0
17,5
3,50
6,5
15,5
3,50
8,0
18,0
3,50
8,5
19,0
4,00
6,5
17,0
4,00
8,5
19,5
4,00
9,0
20,5
4,50
4,0
15,0
4,50
9,0
21,0
4,50
10,0
22,0
ETSU 1W (150lm) min. 0,5lx
5,00
9,0
22,0
5,00
10,0
23,5
6,00
6,0
21,0
6,00
10,5
26,5
ETSU 2W (300lm) min. 0,5lx
ETSU 3W (360lm) min. 0,5lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
3,0
7,5
2,50
3,5
8,5
2,50
4,0
9,0
3,00
3,0
8,0
3,00
4,0
9,5
3,00
4,5
10,0
3,50
3,5
9,0
3,50
4,5
10,5
3,50
5,0
11,0
4,00
4,0
10,0
4,00
5,0
11,5
4,00
5,0
11,5
4,50
4,5
10,5
4,50
5,5
12,0
4,50
5,5
12,5
5,00
4,5
10,5
5,00
5,5
13,0
5,00
5,5
13,5
6,00
4,5
11,0
6,00
5,5
14,0
6,00
6,0
15,0
7,00
3,5
11,0
7,00
6,0
15,0
7,00
6,5
16,5
8,00
3,0
10,5
8,00
6,0
16,0
8,00
7,0
18,5
ETSU 1W (150lm) min. 1 lx
138
ETS 3W (360lm) min. 0,5lx
h [m]
ETSU 2W (300lm) min. 1 lx
ETSU 3W (425lm) min. 1 lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
3,5
7,5
2,50
4,0
8,5
2,50
4,0
9,0
3,00
3,5
8,5
3,00
4,5
9,5
3,00
4,5
10,0
3,50
4,0
9,5
3,50
4,5
10,5
3,50
5,0
11,0
4,00
4,0
10,0
4,00
5,0
11,5
4,00
5,5
12,0
4,50
4,5
11,0
4,50
5,5
12,5
4,50
6,0
14,0
5,00
4,5
11,5
5,00
5,5
13,5
5,00
6,0
14,0
6,00
1,0
10,0
6,00
6,5
15,0
6,00
6,5
15,5 17,0
7,00
6,5
16,0
7,00
7,0
8,00
7,0
17,0
8,00
7,5
Information for readers Photometry of EXIT M – ETE
L1
L2
h
L1 – distance from the wall to the first fixture L2 – distance between fixtures h – height of the ceiling
ETE – LED 1W
ETE – LED 2W
ETE – LED 3W
139
ETE 1W (130lm) min. 1lx
ETE 1W (130lm) min. 0,5lx
h [m]
L1
L2
h [m]
L1
L2
2,50
3,5
8,0
2,50
2,5
8,5
3,00
3,0
8,5
3,00
2,5
9,0
3,50
3,0
9,0
3,50
3,0
10,0
4,00
3,0
9,0
4,00
3,0
10,5
4,50
3,5
9,5
4,50
3,0
10,5
5,00
3,0
9,5
5,00
3,0
11,0
6,00
2,0
8,5
6,00
2,5
12,0
ETE 2W (270lm) min. 1lx
ETE 2W (270lm) min. 0,5lx
h [m]
L1
L2
h [m]
L1
L2
2,50
4,5
10,5
2,50
4,0
10,0
3,00
4,0
11,5
3,00
4,5
12,5
3,50
4,0
12,0
3,50
4,5
11,5
4,00
4,5
12,5
4,00
4,5
12,0
4,50
4,5
13,5
4,50
4,5
12,5
5,00
4,5
14,0
5,00
4,5
13,5
6,00
4,5
15,0
6,00
4,5
13,5
7,00
5,0
15,5
7,00
4,5
14,0
8,00
4,5
15,5
8,00
4,0
13,5
9,00
4,0
15,0
9,00
3,0
13,5
10,00
3,5
14,5
10,00
2,0
13,0
ETE 3W (350lm) min. 1lx
ETE 3W (350lm) min. 0,5lx
h [m]
L1
L2
h [m]
L1
L2
2,50
4,5
10,5
2,50
4,0
11,0
3,00
4,0
11,5
3,00
4,0
11,5
3,50
5,0
12,5
3,50
4,5
13,0
4,00
5,0
13,5
4,00
4,5
14,0
4,50
5,0
13,5
4,50
4,5
14,5
5,00
5,5
14,0
5,00
4,5
15,5
6,00
5,5
15,0
6,00
5,0
16,5
7,00
5,5
15,5
7,00
5,5
18,0
8,00
5,0
15,5
8,00
5,5
18,5
9,00
4,5
15,0
9,00
5,0
19,5
10,00
3,5
15,0
10,00
4,5
20,5
Information for readers Photometry of EXIT L – ETL
L1
L2
h
L1 – distance from the wall to the first fixture L2 – distance between fixtures h – height of the ceiling
ETL – LED 1W, 2W, 3W, 6W
ETL 1W (140lm) min. 0,5lx
ETL 2W (280lm) min. 0,5lx
ETL 3W (425lm) min. 0,5lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
2,5
8,5
2,50
3,0
10,0
2,50
4,0
11,0
3,00
2,5
9,5
3,00
3,5
11,0
3,00
4,0
12,0
3,50
3,0
10,0
3,50
4,0
12,0
3,50
4,0
13,0
4,00
3,0
10,5
4,00
4,0
13,0
4,00
4,5
14,0
4,50
3,0
11,0
4,50
4,0
13,5
4,50
4,5
15,0
5,00
3,0
11,5
5,00
4,0
14,5
5,00
5,0
16,0
6,00
3,5
12,0
6,00
4,5
15,5
6,00
5,5
17,5
7,00
3,0
13,0
7,00
45
16,5
7,00
5,5
18,5
8,00
2,5
13,0
8,00
4,5
17,5
8,00
5,5
20,0
9,00
4,5
18,0
9,00
5,5
20,5
10,00
4,0
19,0
10,00
5,5
21,5
ETL 6W (850lm) min. 0,5lx h [m]
L1
L2
4,00
5,5
16,5
4,50
6,0
18,0
5,00
6,0
19,0
6,00
6,5
21,0
7,00
7,0
22,5
8,00
7,5
24,0
9,00
7,5
25,5
10,0
8,0
26,5
11,0
8,0
27,5
12,0
8,0
28,5
ETL 1W (140lm) min. 1lx
ETL 2W (280lm) min. 1lx
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
3,0
8,0
2,50
4,0
10,0
2,50
4,5
11,0
3,00
3,5
8,5
3,00
4,5
10,5
3,00
5,0
12,0
3,50
3,5
9,0
3,50
4,5
11,5
3,50
5,5
13,0
4,00
3,5
9,5
4,00
4,5
12,0
4,00
5,5
13,5
4,50
3,5
9,5
4,50
5,0
12,5
4,50
6,0
14,5
5,00
3,5
9,5
5,00
5,0
13,0
5,00
6,0
15,0
6,00
3,0
9,0
6,00
5,0
13,0
6,00
6,0
16,0
7,00
2,0
9,0
ETL 6W (850lm) min. 1lx h [m]
140
ETL 3W (425lm) min. 1lx
h [m]
L1
L2
4,00
7,0
16,5
4,50
7,5
17,5
5,00
7,5
18,5
6,00
8,0
20,0
7,00
8,5
21,5
8,00
8,5
22,5
9,00
8,5
23,0
10,0
8,5
24,0
11,0
8,5
24,0
12,0
8,0
24,5
7,00
4,5
14,0
7,00
6,0
16,5
8,00
4,0
14,0
8,00
6,0
17,0
9,00
3,5
13,5
9,00
5,5
17,0
10,00
2,5
13,0
10,00
5,0
17,0
Information for readers Photometry of HELIOS LED – HWM, HWD, HHP
L1
L2
h
L1 – distance from the wall to the first fixture L2 – distance between fixtures h – height of the ceiling
HWM 3W (360lm) min. 1lx
HWM – for 2,5 to 10 m BZ2
=99%
90°
90°
75°
70
60°
2,50
5,00
10,00
5,50
11,00
3,00
5,00
11,00
11,50
3,50
6,00
11,50
4,00
6,00
12,00
4,00
6,00
12,50
45°
4,50
6,00
12,50
4,50
7,00
13,00
5,00
6,00
13,00
5,00
7,00
14,00
5,50
6,00
13,00
5,50
7,00
15,00
6,00
6,00
13,00
6,00
7,00
15,00
6,50
5,60
13,00
6,50
7,00
15,50
7,00
5,50
13,00
7,00
7,00
16,00
7,50
5,00
12,50
7,50
7,00
17,00
8,00
3,00
12,50
8,00
7,00
17,00
9,00
2,50
12,00
9,00
7,00
17,50
10,00
2,50
12,00
10,00
7,00
18,00
HWD 3x1W (370lm) min. 1lx
HWD – for 8 to 14m
HHP – for 2,5 to 14m wide range =100% 105
90°
HWD 3x1W (370lm) min. 0,5lx
h [m]
L1
L2
h [m]
L1
L2
8,00
5,00
9,00
8,00
5,00
9,00
8,50
5,50
10,00
8,50
5,00
9,00
9,00
6,00
10,00
9,00
5,00
9,00
9,50
6,00
10,00
9,50
6,00
9,50
10,00
6,00
10,50
10,00
6,00
10,00
10,50
6,00
11,00
10,50
6,00
10,50
11,00
6,00
11,00
11,00
6,00
10,50
11,50
6,00
11,50
11,50
7,00
11,00
12,00
6,00
12,00
12,00
7,00
11,00
13,00
6,00
12,00
13,00
7,00
12,00
14,00
6,00
11,00
14,00
7,00
12,00
HHP 6x1W (920lm) min. 1lx
HHP 6x1W (920lm) min. 0,5lx
HHP 6x1W (920lm) avg. 10,8lx open area
HHP 6x1W (920lm) avg. 10,8lx escape route
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
3,00
6,0
14,5
4,00
5,5
17,0
2,50
3,0
8,0
2,50
5,0
12,0
3,50
7,0
15,5
5,00
6,0
18,0
3,00
3,5
8,0
3,00
5,5
13,0
4,00
7,0
16,5
6,00
6,5
19,5
3,50
2,5
8,0
3,50
5,5
10,5
5,00
7,0
18,0
7,00
7,0
22,5
4,00
2,5
7,5
4,00
5,5
8,5
6,00
7,5
19,5
8,00
7,5
23,5
5,00
1,5
7,5
5,00
4,0
7,5
7,00
8,0
20,5
9,00
8,0
24,0
6,00
1,5
7,0
6,00
2,5
5,5
8,00
8,0
21,5
10,0
7,5
26,0
7,00
2,5
4,0
9,00
8,0
22,0
11,0
7,5
26,5
10,0
7,5
22,0
12,0
7,5
28,0
11,0
7,0
22,0
13,0
7,0
28,5
12,0
6,5
21,5
14,0
7,0
28,5
90° 70
60°
75° 60°
140 45°
45° 210 280
30° 15° 0° 15° I(0°)=299cd/klm[ cd/klm] C0-C180 C90-C270
141
L2
10,00
6,00
30°
75°
L1
5,50
3,00
350 0° 15° 15° I(0°)=347cd/klm[ cd/klm] C0-C180 C90-C270
1°05° 1°20 1°80 1°20
h [m]
2,50
3,50
280
BZ2
L2
60°
210
30°
L1
75°
140 45°
HWM 3W (360lm) min. 0,5lx
h [m]
30°
Information for readers Photometry of LOVATO 2 – LV2C, LV2R, LV2O, LV2U, LV2A
L1
L2
h
L1 – distance from the wall to the first fixture L2 – distance between fixtures h – height of the ceiling
LV2C 1W (150lm) min.1lx
LV2C - with optics for corridor
LV2R – with optics for escape route BZ5 135° 150°
180°
=100% 150° 135°
120°
120°
LV2C 2W (240lm) min.1lx
LV2C 3W (360lm) min.1lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
5,5
15,0
2,50
6,5
17,5
2,50
7,5
19,0
3,00
5,5
16,0
3,00
7,0
19,0
3,00
8,0
20,5
3,50
5,0
16,0
3,50
7,0
19,0
3,50
8,5
21,0
4,00
5,0
16,5
4,00
7,0
19,5
4,00
9,0
23,0
4,50
5,0
16,5
4,50
7,0
19,5
4,50
9,0
24,0
5,00
4,5
16,5
LV2R 1W (140lm) min. 1lx
5,00
6,5
20,0
5,00
9,5
25,0
6,00
6,5
20,5
6,00
10,0
26,0
7,00
6,5
21,0
7,00
10,0
28,0
8,00
9,5
29,0
LV2R 2W (250lm) min. 1lx
LV2R 3W (370lm) min. 1lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
6,0
14,0
2,50
7,0
16,0
2,50
7,5
17,0
3,00
6,5
15,5
3,00
7,5
17,5
3,00
8,0
18,5
105°
105°
3,50
7,0
17,0
3,50
8,0
19,0
3,50
9,0
20,0
90°
90°
4,00
6,5
18,0
400
75°
75°
400
60°
60° 800
45°
4,00
9,0
21,0
4,00
9,5
22,0
4,50
9,5
22,5
4,50
10,0
23,5
5,00
9,5
24,0
5,00
10,5
25,0
6,00
9,5
25,0
6,00
10,5
27,0
45° 1200
30° 15° I(0°)=107cd/kl C0-C180
0°
15°
30° cd/klm]
C90-C270
LV2O – with optics for open area
142
LV2O 1W (140lm) min. 0,5lx
LV2O 2W (270lm) min. 0,5lx
LV2O 3W (390lm) min. 0,5lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
3,0
11,0
2,50
5,0
16,5
2,50
5,0
18,0
3,00
2,5
11,5
3,00
5,0
16,5
3,00
5,0
18,0
3,50
2,5
13,0
3,50
4,5
17,0
3,50
4,5
18,0
4,00
2,5
12,5
4,00
4,0
17,0
4,00
4,5
18,5
4,50
2,5
12,5
4,50
4,0
17,0
4,50
4,0
20,0 20,0
5,00
2,0
11,0
5,00
3,5
17,0
5,00
3,5
6,00
1,5
10,5
6,00
3,5
16,0
6,00
3,,5
19,5
7,00
4,0
18,5
8,00
4,0
18,0
Information for readers LV2U – with universal optics
LV2U 1W (140lm) min. 0,5lx
=100% 150° 135°
LV2U 2W (270lm) min. 0,5lx
LV2U 3W (390lm) min. 0,5lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
105°
2,50
3,0
7,0
2,50
3,5
7,5
2,50
3,5
8,5
90°
90°
3,00
3,5
7,5
3,00
3,5
9,0
3,00
4,0
9,5
75°
75°
3,50
3,5
8,5
3,50
4,0
10,0
3,50
4,0
10,5
4,00
4,0
9,5
4,00
4,5
11,0
4,00
5,0
11,0
4,50
4,0
10,0
4,50
4,5
12,0
4,50
5,5
12,5
BZ2
135° 150°
180°
105°
160
60°
60° 320
45°
45°
5,00
4,0
10,5
5,00
5,0
12,5
5,00
5,5
13,5
6,00
4,0
10,5
6,00
5,5
13,5
6,00
6,0
15,0
480
640 30°
15°
0°
15°
I(0°)=196cd/klm C0-C180
30° [cd/klm]
C90-C270
LV2A – with asymmetric optics
143
LV2A 1W (140lm) min. 1lx
LV2A 2W (280lm) min. 1lx
LV2A 3W (370lm) min. 1lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
3,0
9,5
2,50
5,0
12,0
2,50
5,5
13,5
3,00
2,5
9,5
3,00
5,0
13,0
3,00
5,5
14,5
3,50
2,5
8,5
3,50
4,0
14,0
3,50
5,5
15,0
4,00
2,5
7,5
4,00
4,0
13,5
4,00
4,5
16,0
4,50
2,0
7,0
4,50
3,5
13,5
4,50
4,5
16,0
5,00
1,5
7,0
5,00
3,5
11,5
5,00
4,5
15,0
6,00
1,0
5,0
6,00
3,0
10,0
6,00
4,0
11,5
7,00
3,0
8,0
7,00
4,0
11,0
8,00
2,0
8,0
8,00
3,0
10,0
Information for readers Photometry of LOVATO P – LVPC, LVPR, LVPO, LVPU, LVPA
L1
L2
h
L1 – distance from the wall to the first fixture L2 – distance between fixtures h – height of the ceiling
LVPC 1W (150lm) min.1lx
LVPC - with optics for corridor
LVPR – with optics for escape route BZ4 1°35° 150
180°
=100% 1°50° 135
120°
120° 400
105°
105°
90° 75°
90° 75°
400
60°
LVPC 2W (270lm) min.1lx
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
6,0
14,5
2,50
6,5
16,0
2,50
7,0
16,0
3,00
6,5
16,0
3,00
7,5
18,0
3,00
8,0
18,5
3,50
6,5
17,0
3,50
8,0
20,0
3,50
9,0
21,0
4,00
7,0
17,5
4,00
8,0
21,0
4,00
9,5
22,5
4,50
7,0
18,0
4,50
8,5
22,0
4,50
10,0
25,0
5,00
7,0
17,5
5,00
9,0
24,5
5,00
10,5
26,5
6,00
6,5
15,0
6,00
9,5
25,0
6,00
11,0
27,0
7,00
10,0
26,0
LVPR 1W (150lm) min. 1lx
LVPR 2W (270lm) min. 1lx
7,00
11,5
28,0
8,00
11,0
28,0
LVPR 3W (370lm) min. 1lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
5,0
11,0
2,50
6,0
13,0
2,50
6,0
14,0
3,00
5,5
13,0
3,00
6,5
14,5
3,00
6,5
15,5
3,50
6,0
14,0
3,50
7,0
16,0
3,50
7,5
17,0
4,00
6,5
15,0
60° 800
45°
LVPC 3W (350lm) min.1lx
h [m]
45°
4,00
7,5
17,5
4,00
8,0
18,0
4,50
8,0
18,5
4,50
9,0
20,0
5,00
8,5
19,5
5,00
9,0
21,0
6,00
9,0
20,0
6,00
9,0
21,5
1200 30° 15° I(0°)=94cd/klm C0-C180
0°
15°
30° [cd/klm] C90-C270
LV2O – with optics for open area
144
LVPO 1W (140lm) min.0,5lx
LVPO 2W (270lm) min.0,5lx
LVPO 3W (360lm) min.0,5lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
4,0
10,5
2,50
5,0
11,5
2,50
5,0
12,0
3,00
4,5
11,5
3,00
5,5
12,5
3,00
5,5
13,0
3,50
5,0
13,0
3,50
6,0
14,5
3,50
6,5
15,5
4,00
2,5
12,0
4,00
6,5
16,0
4,00
7,0
16,5
4,50
2,0
11,5
4,50
7,0
16,5
4,50
7,5
18,0
5,00
2,5
11,0
5,00
6,5
14,5
5,00
8,0
19,5
6,00
2,0
10,0
6,00
2,5
14,0
6,00
4,0
18,0
7,00
2,5
13,5
7,00
2,5
18,0
8,00
2,0
13,0
8,00
2,5
17,5
Information for readers LVPU – with universal optics
LVPU 1W (150lm) min.0,5lx
LVPU 2W (280lm) min. 0,5lx
LVPU 3W (390lm) min. 0,5lx h [m]
L1
L2
105°
105°
2,50
3,0
6,5
2,50
3,5
7,5
2,50
3,5
8,0
90°
90°
3,00
3,0
7,0
3,00
4,0
8,0
3,00
4,0
8,5
75°
3,50
3,5
7,5
3,50
4,0
9,0
3,50
4,5
9,5
4,00
3,5
8,5
4,00
4,5
9,5
4,00
4,5
10,5
4,50
4,0
8,5
4,50
5,0
10,0
4,50
5,5
11,0
5,00
4,5
9,0
5,00
5,0
11,0
5,00
6,0
12,5
6,00
4,5
8,0
6,00
5,5
11,0
6,00
6,5
13,5
BZ2 1°35° 180
75°
=100% 120°
200
60°
60° 400
45°
45° 600
h [m]
L1
L2
h [m]
L1
L2
800 30° 15° 0° 15° 30° I(0°)=219cd/klm [cd/klm] C0-C180 C90-C270
LVPA – with asymmetric optics
145
LVPA 1W (140lm) min. 1lx
LVPA 2W (270lm) min. 1lx
LVPA 3W (360lm) min. 1lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
1,5
11,5
2,50
8,0
15,0
2,50
9,0
21,5
3,00
1,5
12,0
3,00
2,5
15,5
3,00
3,0
18,5
3,50
2,5
7,5
3,50
3,0
15,5
3,50
3,0
18,0
4,00
2,5
7,5
4,00
3,0
15,5
4,00
3,0
18,0
4,50
2,5
7,0
4,50
4,0
9,0
4,50
3,0
17,5
5,00
2,0
7,0
5,00
4,5
9,0
5,00
4,0
11,0
6,00
2,0
6,0
6,00
4,0
9,0
6,00
4,5
11,0
7,00
4,0
8,0
7,00
4,0
11,0
8,00
3,5
8,0
8,00
4,0
10,5
Information for readers Photometry of ARROW N - ARNS, ARNC, ARNO
L1
L2
h
L1 – distance from the wall to the first fixture L2 – distance between fixtures h – height of the ceiling
ARNS – without optics BZ2
ARNS 1W (120lm) min.0,5lx
90° 75°
80
60°
L1
L2
h [m]
L1
L2
90°
2,50
2,5
8,0
2,50
3,0
9,0
75°
3,00
3,0
8,5
3,00
3,0
9,5
60°
3,50
3,0
9,5
3,50
3,5
10,5
4,00
3,5
10,0
4,00
4,0
11,5
45°
4,50
3,5
10,5
4,50
4,0
12,0
160 45° 240 320 30°
30°
400 15° 0° 15° I(0°)=374cd/klm [cd/klm] C0-C180 C90-C270
ARNC – with optics for escape route BZ1
75°
200
60°
11,0
5,00
4,0
13,0
11,5
6,00
4,0
14,0
7,00
2,5
11,5
7,00
4,0
14,5
8,00
2,0
11,0
8,00
3,5
14,0
ARNC 3x1W (270lm) min.1lx L1
L2
2,50
3,5
8,0
75°
3,00
4,0
9,0
3,50
4,0
10,0
60°
45° 600 800
30°
3,0 3,0
h [m]
400 45°
5,00 6,00
90°
=100%
90°
ARNS 2W (220lm) min.0,5lx
h [m]
=100%
4,00
4,0
10,5
4,50
4,5
11,0
5,00
4,5
11,5
6,00
4,5
12,0
30°
1000 15° 0° 15° I(0°)=889cd/klm [cd/klm] C0-C180 C90-C270
ARNO – with optics for open area BZ1 90° 75°
400
60°
h [m]
L1
L2
2,50
3,0
8,5
75°
3,00
3,0
9,0
60°
3,50
3,0
10,0
4,00
3,0
10,5
45°
4,50
3,0
11,0
800 45° 1200 1600 30° 2000 15° 0° 15° I(0°)=1694cd/klm [cd/klm] C0-C180 C90-C270
146
ARNO 3x1W (270lm) min.0,5lx
90°
=100%
30°
5,00
3,0
11,5
6,00
3,0
12,0
Information for readers Photometry of ARROW P – ARPS, ARPC, ARPO
L1
L2
h
L1 – distance from the wall to the first fixture L2 – distance between fixtures h – height of the ceiling
ARPS – without optics BZ2
ARPS 1W (120lm) min. 0,5lx
90° 75°
80
60°
L1
L2
h [m]
L1
L2
90°
2,50
2,5
8,0
2,50
3,0
9,0
75°
3,00
3,0
8,5
3,00
3,0
9,5
60°
3,50
3,0
9,5
3,50
3,5
10,5
4,00
3,5
10,0
4,00
4,0
11,5
45°
4,50
3,5
10,5
4,50
3,0
12,0
160 45° 240 320 30°
30°
400 15° 0° 15° I(0°)=374cd/klm [cd/klm] C0-C180 C90-C270
ARPC – with optics for escape route BZ1
75°
200
60°
11,0
5,00
3,0
13,0
11,5
6,00
2,0
14,0
7,00
2,5
11,5
7,00
2,0
14,5
8,00
2,0
11,0
8,00
2,0
14,0
ARPC 3x1W (270lm) min. 1lx L1
L2
2,50
3,5
8,0
75°
3,00
4,0
9,0
3,50
4,0
10,0
60°
45° 600 800
30°
3,0 3,0
h [m]
400 45°
5,00 6,00
90°
=100%
90°
ARPS 2W (220lm) min. 0,5lx
h [m]
=100%
4,00
4,0
10,5
4,50
4,5
11,0
5,00
4,5
11,5
6,00
4,5
12,0
30°
1000 15° 0° 15° I(0°)=889cd/klm [cd/klm] C0-C180 C90-C270
ARPO – with optics for open area BZ1 90° 75°
400
60°
h [m]
L1
L2
2,50
3,0
8,5
75°
3,00
3,0
9,0
60°
3,50
3,0
10,0
4,00
3,0
10,5
45°
4,50
3,0
11,0
800 45° 1200 1600 30° 2000 15° 0° 15° I(0°)=1694cd/klm [cd/klm] C0-C180 C90-C270
147
ARPO 3x1W (270lm) min. 0,5lx
90°
=100%
30°
5,00
3,0
11,5
6,00
3,0
12,0
Information for readers Photometry of AXN – AXNC, AXNR, AXNO, AXNU, AXNA
L1
L2
h
L1 – distance from the wall to the first fixture L2 – distance between fixtures h – height of the ceiling
AXNC 1W (150lm) min.1lx
AXNC – with optics for corridor
AXNR – with optics for escape route BZ5 135° 150°
180°
=100% 150° 135°
120°
AXNC 2W (260lm) min. 1lx
AXNC 3W (360lm) min.1lx
AXNC 6W (600lm) min.1lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
5,5
15,0
2,5
7,0
17,0
2,50
8,0
19,0
2,50
10,0
23,0
3,00
5,5
16,0
3,0
7,5
18,0
3,00
8,0
20,0
3,00
10,5
25,0
3,50
6,0
16,0
3,5
8,0
19,0
3,50
8,5
21,0
3,50
11,0
27,0
4,00
6,0
16,5
4,0
8,5
20,5
4,00
9,0
22,5
4,00
11,0
28,5
4,50
5,5
16,0
5,0
9,0
22,0
4,50
9,5
24,0
4,50
11,5
29,5
5,00
5,0
16,0
6,0
9,0
23,5
5,00
10
25,0
5,00
12,0
30,5
6,00
5,0
13,0
7,0
8,0
22,5
6,00
10,5
26,0
6,00
12,5
32,0
8,0
7,5
15,5
7,00
10,0
27,0
7,00
12,5
34,0
9,0
7,0
13,5
8,00
9,5
27,0
8,00
13,0
35,0
10,0
7,5
11,5
9,00
9,0
21,0
9,00
13,0
36,0
11,0
7,5
10,0
10,00
8,5
17,0
10,00
12,5
37,0
12,0
7,0
8,5
AXNR 1W (150lm) min. 1lx
AXNR 2W (250lm) min. 1lx
AXNR 3W (370lm) min. 1lx
AXNR 6W (600lm) min. 1lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
5,5
12,0
2,50
5,5
13,0
2,50
6,0
15,0
2,50
7,5
20,0
3,00
6,5
13,5
3,00
6,5
14,5
3,00
7,0
15,5
3,00
8,5
21,0
3,50
7,0
15,0
3,50
7,5
16,5
3,50
8,0
17,0
3,50
9,5
21,5
4,00
7,5
17,0
4,00
8,5
18,0
4,00
8,5
19,0
4,00
10,5
22,5
4,50
9,0
20,0
4,50
9,5
20,5
4,50
11,0
23,5
5,00
10,0
21,0
5,00
10,5
22,0
5,00
11,5
25,0
6,00
11,5
25,0
6,00
13,0
29,0
120° 500
105°
105°
90°
90°
75°
75°
500
60°
60° 1000
45°
45° 1500
30° 15° I(0°)=103cd/kl C0-C180
0°
15°
30° cd/klm]
C90-C270
AXNO –with optics for opean area AXNO 1W (145lm) min.0,5lx BZ5 135° 150°
180°
=100% 150° 135°
120°
AXNO 3W (350lm) min.0,5lx
AXNO 6W (590lm) min.0,5lx
L1
L2
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
2,5
14,0
2,5
3,5
14,0
2,50
5,0
17,5
2,50
6,0
19,5
3,00
2,0
13,5
3,0
2,5
13,5
3,00
4,5
17,5
3,00
6,0
20,0
3,50
2,0
13,5
3,5
2,0
13,5
3,50
4,0
19,0
3,50
6,5
22,0
4,00
2,0
13,0
4,0
2,5
13,0
4,00
3,5
19,0
4,00
6,0
23,0
4,50
1,5
12,5
5,0
2,0
12,5
4,50
3,0
20,0
4,50
5,5
24,0
5,00
1,5
12,5
6,0
2,0
12,5
5,00
3,0
20,0
5,00
5,0
25,0
6,00
1,5
12,0
7,0
2,0
12,0
6,00
2,0
20,0
6,00
4,0
26,0
8,0
2,0
2,0
7,00
2,0
20,0
7,00
4,0
26,5
9,0
2,0
1,5
8,00
2,0
19,0
8,00
4,0
26,5
10,0
2,0
1,5
9,00
4,0
26,5
11,0
1,5
1,5
10,00
4,0
26,0
120° 500
105°
105°
90°
90°
75°
AXNO 2W (250lm) min. 0,5lx
h [m]
75°
500
60°
60° 1000
45°
45° 1500
30° 15° I(0°)=103cd/kl C0-C180
148
0°
15° C90-C270
30° cd/klm]
Information for readers AXNU – with universal optics BZ2 105°
AXNU 1W (150lm) min.0,5lx
=100% 120° 105°
135°180°
AXNU 2W (270lm) min. 0,5lx
AXNU 3W (390lm) min. 0,5lx
AXNU 6W (620lm) min. 0,5lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
3,0
6,5
2,50
3,5
7,5
2,50
3,5
8,0
2,50
4,0
8,5
90°
90°
3,00
3,0
7,5
3,00
4,0
8,0
3,00
3,5
8,5
3,00
4,0
9,5
75°
75°
3,50
3,5
8,0
3,50
4,0
9,0
3,50
4,5
9,5
3,50
4,5
10,5
60°
4,00
3,5
8,5
4,00
4,5
10,0
4,00
4,5
10,5
4,00
5,0
11,0
4,50
4,0
8,5
4,50
5,0
11,0
4,50
5,5
11,0
4,50
5,5
12,0
5,00
4,5
9,0
5,00
5,0
11,0
5,00
5,5
12,5
5,00
6,0
13,0
6,00
4,5
8,0
6,00
5,5
11,0
6,00
6,0
13,5
6,00
7,0
14,0
300
60° 600 45°
45° 900 1200
30°
15° I(0°)=242cd/kl C0-C180
0°
30°
15° cd/klm] C90-C270
AXNA – with asymmetric optics BZ9 135°
150° 165°180°165°
=100% 150° 135°
320 120°
120° 160
105°
105°
90°
90°
75°
160
75° 60°
60° 320 45° 30° 15° 0° 15° 30° cd/klm] I(180°)=101cd/kl C0-C180 C90-C270
149
45°
AXNA 1W (140lm) min. 1lx
AXNA 2W (260lm) min. 1lx
AXNA 3W (380lm) min. 1lx
AXNA 6W (580lm) min. 1lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
2,5
10,0
2,50
5,0
13,0
2,50
6,0
16,5
2,50
7,5
19,5
3,00
2,5
8,5
3,00
4,0
12,5
3,00
5,0
17,0
3,00
7,5
20,5
3,50
2,0
7,5
3,50
3,5
12,0
3,50
4,5
17,0
3,50
7,0
21,0
4,00
1,5
7,0
4,00
3,5
10,0
4,00
4,0
16,0
4,00
6,0
21,0
4,50
3,0
9,0
4,50
3,5
14,5
4,50
5,5
21,0
5,00
3,0
8,0
5,00
3,0
14,0
5,00
5,0
20,0
6,00
2,0
7,0
6,00
2,5
12,0
6,00
4,5
16,0
Information for readers Photometry of AXP – AXPC, AXPR, AXPO, AXPU, AXPA
L1
L2
h
L1 – distance from the wall to the first fixture L2 – distance between fixtures h – height of the ceiling
AXPC 1W (160lm) min. 1lx
AXPC – with optics for corridor
AXPR – with optics for escape route BZ5 135° 150°
180°
=100% 150° 135°
120°
AXPC 2W (260lm) min. 1lx
AXPC 3W (370lm) min. 1lx
AXPC 6W (600lm) min. 1lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
5,5
15,0
2,5
7,0
17,5
2,50
8,0
19,0
2,50
10,0
23,0
3,00
5,5
16,0
3,0
7,5
18,5
3,00
8,0
20,5
3,00
10,5
25,5
3,50
6,0
16,5
3,5
7,5
19,5
3,50
8,5
21,5
3,50
11,0
27,0
4,00
6,5
17,0
4,0
8,0
20,5
4,00
9,0
23,0
4,00
11,5
29,0
4,50
6,0
16,5
5,0
8,5
22,0
4,50
9,5
24,0
4,50
12,0
30,0
5,00
6,0
16,5
6,0
9,0
23,0
5,00
10,0
25,0
5,00
12,0
31,0
6,00
5,5
14,0
7,0
9,0
23,0
6,00
10,5
26,5
6,00
12,5
32,0
8,0
9,0
16,0
7,00
10,5
28,0
7,00
13,5
35,0
9,0
9,5
14,0
8,00
10,0
27,5
8,00
14,0
36,0
10,0
7,5
12,0
9,00
14,5
37,0
10,00
14,5
38,0
AXPR 1W (150lm) min. 1lx
11,0
7,0
11,5
12,00
7,0
9,5
AXPR 2W (250lm) min. 1lx
AXPR 3W (370lm) min. 1lx
AXPR 6W (600lm) min. 1lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
5,5
13,0
2,50
6,0
14,0
2,50
6,5
16,5
2,50
8,0
20,0
3,00
6,5
14,0
3,00
7,0
15,0
3,00
7,5
17,5
3,00
8,5
21,0
3,50
7,0
15,5
3,50
7,5
17,5
3,50
8,0
19,0
3,50
9,5
21,0
4,00
7,5
17,0
4,00
8,5
19,0
4,00
9,0
20,5
4,00
10,5
22,5
4,50
9,0
20,0
4,50
9,0
22,0
4,50
10,5
23,5
5,00
9,5
21,0
5,00
10,5
22,5
5,00
11,5
25,0
6,00
10,0
22,0
6,00
10,5
23,5
6,00
13,0
29,0
120° 500
105°
105°
90°
90°
75°
75°
500
60°
60° 1000
45°
45° 1500
30° 15° I(0°)=103cd/kl C0-C180
0°
15°
30° cd/klm]
C90-C270
AXPO – with optics for open area BZ5 135° 150°
180°
=100% 150° 135°
120°
AXPO 2W (260lm) min. 0,5lx
AXPO 3W (375lm) min. 0,5lx
AXPO 6W (615lm) min. 0,5lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
2,5
13,5
2,5
5,0
15,0
2,50
6,5
17,0
2,50
6,0
19,5
3,00
2,0
13,5
3,0
4,5
16,5
3,00
6,5
18,0
3,00
6,0
20,0
3,50
2,0
13,5
3,5
4,0
18,0
3,50
6,5
20,0
3,50
6,5
22,0
4,00
2,0
13,0
4,0
2,5
19,0
4,00
5,5
21,5
4,00
6,0
23,0
4,50
1,5
12,5
5,0
2,0
18,5
4,50
5,0
22,5
4,50
5,5
24,0
5,00
1,5
12,5
6,0
2,0
18,0
5,00
4,0
23,0
5,00
5,0
25,0
6,00
1,5
12,0
7,0
2,0
17,0
6,00
4,0
22,5
6,00
4,0
26,0
8,0
2,0
16,5
7,00
4,0
22,0
7,00
4,0
26,5
9,0
2,0
16,5
8,00
3,0
21,0
8,00
4,0
26,5
10,0
1,5
16,5
9,00
4,0
26,5
11,0
1,0
14,5
10,00
2,5
26,0
11,00
2,0
26,0
120° 500
105°
105°
90°
90°
75°
AXPO 1W (145lm) min. 0,5lx
75°
500
60°
60° 1000
45°
45° 1500
30° 15° I(0°)=103cd/kl C0-C180
150
0°
15° C90-C270
30° cd/klm]
Information for readers AXPU – with universal optics BZ2 105°
AXPU 1W (140lm) min.0,5lx
=100% 120° 105°
135°180°
AXPU 2W (270lm) min. 0,5lx
AXPU 3W (390lm) min. 0,5lx
AXPU 6W (620lm) min. 0,5lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
3,5
6,5
2,50
3,5
7,5
2,50
3,5
8,0
2,50
4,0
8,5
90°
90°
3,00
3,5
7,5
3,00
4,0
8,0
3,00
4,0
8,5
3,00
4,5
9,5
75°
75°
3,50
3,5
8,0
3,50
4,0
9,0
3,50
4,0
9,5
3,50
4,5
10,5
60°
4,00
3,5
8,5
4,00
4,5
10,0
4,00
4,5
10,5
4,00
5,5
10,5
4,50
4,0
8,5
4,50
5,0
11,0
4,50
5,5
11,0
4,50
5,5
12,0
5,00
4,5
9,0
5,00
5,0
11,0
5,00
6,0
12,5
5,00
6,0
13,0
6,00
4,5
8,0
6,00
5,5
11,0
6,00
6,5
13,5
6,00
7,0
14,0
300
60° 600 45°
45° 900 1200
30°
15° I(0°)=242cd/kl C0-C180
0°
30°
15° cd/klm] C90-C270
AXPA – with asymmetric optics BZ9 135° 150° 165°180°165°
AXPA 1W (140lm) min. 1lx
=100% 150° 135°
320 120°
120° 160
105°
90° 160
75° 60°
60° 320 45° 30° 15° 0° 15° 30° cd/klm] I(180°)=101cd/kl C0-C180 C90-C270
151
AXPA 3W (380lm) min. 1lx
AXPA 6W (580lm) min. 1lx
L1
L2
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
2,5
10,0
2,50
5,0
13,0
2,50
6,0
16,5
2,50
7,5
19,0
3,00
2,5
8,5
3,00
4,0
12,5
3,00
5,0
17,0
3,00
8,0
20,0
3,50
2,0
7,5
3,50
3,5
12,0
3,50
4,5
17,0
3,50
8,0
21,0
4,00
1,5
6,5
4,00
3,5
10,0
4,00
4,0
16,0
4,00
6,0
21,0
4,50
3,0
9,0
4,50
3,5
14,5
4,50
5,5
21,0
5,00
3,0
8,0
5,00
3,0
14,0
5,00
5,0
20,0
6,00
2,0
7,0
6,00
2,5
12,0
6,00
4,5
16,0
105°
90° 75°
AXPA 2W (270lm) min. 1lx
h [m]
45°
Information for readers Photometry of EYE LED round – EYC, EYR, EYO, EYU, EY
L1
L2
h
L1 – distance from the wall to the first fixture L2 – distance between fixtures h – height of the ceiling
EYC 1W (140lm) min. 1lx
EYC – with optics for corridor BZ5 1°35° 150
180°
=100% 1°50° 135
120°
EYC 2W (260lm) min. 1lx
EYC 3W (355lm) min. 1lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
6,0
14,0
2,50
7,0
17,0
2,50
7,5
18,0
120° 400
105°
105°
90°
90°
75°
75°
400
60°
60°
3,00
6,0
15,0
3,00
7,5
18,0
3,00
8,0
19,5
3,50
6,5
16,0
3,50
8,0
20,0
3,50
9,0
21,0
4,00
6,5
17,0
4,00
8,0
21,0
4,00
9,5
22,5
4,50
7,0
18,0
4,50
8,5
22,0
4,50
10,0
24,0
5,00
7,0
17,5
5,00
8,5
23,0
5,00
10,5
25,0
6,00
4,5
12,0
6,00
9,0
24,5
6,00
10,5
27,0
800 45°
45° 1200
30° 15° I(0°)=90cd/klm C0-C180
0°
15°
30° [cd/klm] C90-C270
EYR – with optics for escape route BZ5 1°35° 150
180°
=100% 1°50° 135
120°
EYR 1W (140lm) min. 1lx
EYR 2W (260lm) min. 1lx
EYR 3W (350lm) min. 1lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
5,0
13,0
2,50
6,5
14,5
2,50
7,0
15,5
120° 400
105°
105°
90°
90°
75°
3,00
6,0
14,0
3,00
7,0
16,0
3,00
7,5
17,5
3,50
7,5
16,0
3,50
8,0
18,0
3,50
8,5
19,0
4,00
7,0
15,5
75°
400
60°
60°
4,00
8,5
19,0
4,00
9,0
20,5
4,50
9,0
21,0
4,50
10,0
22,5
5,00
9,5
22,0
5,00
10,5
24,0
6,00
9,5
22,5
6,00
10,5
24,5
800 45°
45° 1200
30° 15° I(0°)=90cd/klm C0-C180
0°
15° 30° [cd/klm] C90-C270
EYO 1W (135lm) min. 0,5lx
EYO - with optics for open area BZ2 1°20° 135
180°
=100% 1°35° 120
105°
105°
90°
90°
75°
160
60°
75° 60°
320 45°
45° 480 640
30° 15° 0° 15° 30° I(0°)=220cd/klm [cd/klm] C0-C180 C90-C270
152
EYO 2W (260lm) min. 0,5lx
EYO 3W (350lm) min. 0,5lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
2,5
13,0
2,50
4,5
14,5
2,50
5,0
16,5
3,00
1,5
12,0
3,00
4,0
13,5
3,00
5,0
16,0
3,50
2,0
12,5
3,50
4,0
15,0
3,50
4,5
17,5
4,00
2,0
12,0
4,00
3,0
16,5
4,00
5,0
18,0
4,50
2,0
12,0
4,50
2,5
17,0
4,50
5,0
18,0
5,00
2,0
12,0
5,00
3,0
16,5
5,00
4,0
19,0
6,00
2,0
10,5
6,00
3,5
16,0
6,00
4,0
18,0
Information for readers EYU – with universal optics BZ2 1°20° 135
180°
EYU 1W (150lm) min. 0,5lx
=100% 1°35° 120
105°
105°
90°
90°
75°
160
60°
75° 60°
320 45°
45° 480
EYU 2W (270lm) min. 0,5lx
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
3,0
7,0
2,50
3,5
7,5
2,50
3,5
8,0
3,00
3,5
7,5
3,00
3,5
8,0
3,00
4,0
9,0
3,50
3,5
8,5
3,50
4,0
9,0
3,50
4,0
10,0
4,00
4,0
9,0
4,00
4,5
10,0
4,00
4,5
10,0
4,50
4,0
10,0
4,50
4,5
11,5
4,50
5,0
11,5
5,00
4,0
10,0
5,00
5,0
12,0
5,00
5,5
12,5
6,00
4,0
9,5
6,00
5,5
13,0
6,00
6,0
14,0
640 30° 15° 0° 15° 30° I(0°)=220cd/klm [cd/klm] C0-C180 C90-C270
EY - without optics
153
EYU 3W (390lm) min. 0,5lx
h [m]
EY 3x1W (360lm) – min. 0,5lx h [m]
L1
L2
2,50
3,5
9,5
3,00
3,5
10,0
3,50
4,5
11,5
4,00
4,5
12,0
4,50
5,0
14,5
5,00
5,0
14,5
6,00
5,5
15,0
7,00
5,0
15,0
8,00
5,5
17,5
Information for readers Photometry of EYE LED square – EYKC, EYKR, EYKO, EYKU, EYK
L1
L2
h
L1 – distance from the wall to the first fixture L2 – distance between fixtures h – height of the ceiling
EYKC 1W (140lm) min. 1lx
EYKC – with optics for corridor BZ5 1°35° 150
180°
=100% 1°50° 135
120°
EYKC 2W (260lm) min. 1lx
EYKC 3W (355lm) min. 1lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
6,0
14,0
2,50
7,0
17,0
2,50
7,5
18,0
120° 400
105°
105°
90°
90°
75°
75°
400
60°
60°
3,00
6,0
15,0
3,00
7,5
18,0
3,00
8,0
19,5
3,50
6,5
16,0
3,50
8,0
20,0
3,50
9,0
21,0
4,00
6,5
17,0
4,00
8,0
21,0
4,00
9,5
22,5
4,50
7,0
18,0
4,50
8,5
22,0
4,50
10,0
24,0
5,00
7,0
17,5
5,00
8,5
23,0
5,00
10,5
25,0
6,00
4,5
12,0
6,00
9,0
24,5
6,00
10,5
27,0
800 45°
45° 1200
30° 15° I(0°)=90cd/klm C0-C180
0°
15°
30° [cd/klm] C90-C270
EYKR – with optics for escape route BZ5 1°35° 150
180°
=100% 1°50° 135
120°
EYKR 1W (140lm) min. 1lx
EYKR 2W (260lm) min. 1lx
EYKR 3W (350lm) min. 1lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
5,0
13,0
2,50
6,5
14,5
2,50
7,0
15,5
120° 400
105°
105°
90°
90°
75°
3,00
6,0
14,0
3,00
7,0
16,0
3,00
7,5
17,5
3,50
7,5
16,0
3,50
8,0
18,0
3,50
8,5
19,0
4,00
7,0
15,5
75°
400
60°
60°
4,00
8,5
19,0
4,00
9,0
20,5
4,50
9,0
21,0
4,50
10,0
22,5
5,00
9,5
22,0
5,00
10,5
24,0
6,00
9,5
22,5
6,00
10,5
24,5
800 45°
45° 1200
30° 15° I(0°)=90cd/klm C0-C180
0°
15° 30° [cd/klm] C90-C270
EYKO - with optics for open area BZ2 1°20° 135
180°
=100% 1°35° 120
105°
105°
90°
90°
75°
160
60°
75° 60°
320 45°
45° 480 640
30° 15° 0° 15° 30° I(0°)=220cd/klm [cd/klm] C0-C180 C90-C270
154
EYKO 1W (135lm) min. 0,5lx
EYKO 2W (260lm) min. 0,5lx
EYKO 3W (350lm) min. 0,5lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
2,5
13,0
2,50
4,5
14,5
2,50
5,0
16,5
3,00
1,5
12,0
3,00
4,0
13,5
3,00
5,0
16,0
3,50
2,0
12,5
3,50
4,0
15,0
3,50
4,5
17,5
4,00
2,0
12,0
4,00
3,0
16,5
4,00
5,0
18,0
4,50
2,0
12,0
4,50
2,5
17,0
4,50
5,0
18,0
5,00
2,0
12,0
5,00
3,0
16,5
5,00
4,0
19,0
6,00
2,0
10,5
6,00
3,5
16,0
6,00
4,0
18,0
Information for readers EYKU – with universal optics BZ2 1°20° 135
180°
EYKU 1W (150lm) min. 0,5lx
=100% 1°35° 120
105°
105°
90°
90°
75°
160
60°
75° 60°
320 45°
45° 480
EYKU 2W (270lm) min. 0,5lx
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
3,0
7,0
2,50
3,5
7,5
2,50
3,5
8,0
3,00
3,5
7,5
3,00
3,5
8,0
3,00
4,0
9,0
3,50
3,5
8,5
3,50
4,0
9,0
3,50
4,0
10,0
4,00
4,0
9,0
4,00
4,5
10,0
4,00
4,5
10,0
4,50
4,0
10,0
4,50
4,5
11,5
4,50
5,0
11,5
5,00
4,0
10,0
5,00
5,0
12,0
5,00
5,5
12,5
6,00
4,0
9,5
6,00
5,5
13,0
6,00
6,0
14,0
640 30° 15° 0° 15° 30° I(0°)=220cd/klm [cd/klm] C0-C180 C90-C270
EYK - without optics
155
EYKU 3W (390lm) min. 0,5lx
h [m]
EYK 3x1W (360lm) – min. 0,5lx h [m]
L1
L2
2,50
3,5
9,5
3,00
3,5
10,0
3,50
4,5
11,5
4,00
4,5
12,0
4,50
5,0
14,5
5,00
5,0
14,5
6,00
5,5
15,0
7,00
5,0
15,0
8,00
5,5
17,5
Information for readers Photometry of MICRO SPOT – MSU, MSR
L1
L2
h
L1 – distance from the wall to the first fixture L2 – distance between fixtures h – height of the ceiling
MSU - with universal optics
MSU 1W (140lm) min. 0,5lx
=100%
BZ2 135° 180°
120°
105°
105°
90°
90°
75°
75°
160
60°
60° 320
45°
45° 480 640
30° 15° 0° 15° 30° I(0°)=245cd/klm [cd/klm] C0-C180 C90-C270
MSR - with optics for escape route BZ5 135° 150°
=100% 180°
150° 135°
MSU 2W (260lm) min. 0,5lx
MSU 3W (380lm) min. 0,5lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
2,5
6,0
2,50
2,0
8,5
2,50
2,0
8,0
3,00
2,0
7,5
3,00
2,0
8,5
3,00
2,0
9,0
3,50
2,0
7,5
3,50
2,0
9,0
3,50
2,5
9,5
4,00
2,0
8,5
4,00
2,0
9,5
4,00
2,5
10,5
4,50
2,5
9,0
4,50
2,0
10,5
4,50
2,5
11,0
5,00
2,5
10,0
5,00
2,5
11,0
5,00
2,5
12,0
11,0
6,00
3,0
12,5
6,00
3,0
13,5
6,00
3,0
7,00
2,5
11,0
7,00
3,5
13,5
7,00
3,5
14,5
8,00
2,5
10,0
8,00
4,0
14,5
8,00
4,0
16,0
MSR 1W (130lm) min. 1lx
MSR 2W (250lm) min. 1lx
MSR 3W (360lm) min. 1lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
5,0
12,0
2,50
6,0
14,0
2,50
6,5
15,5
120°
2,50
105°
105°
3,00
5,5
13,0
3,00
6,5
15,5
3,00
7,0
17,0
90°
90°
3,50
6,5
13,5
3,50
7,0
17,0
3,50
7,5
18,0
75°
75°
4,00
7,0
8,0
4,00
8,0
18,0
4,00
8,5
20,0
60°
4,50
7,0
7,0
4,50
8,5
19,0
4,50
9,0
20,5
120° 400
400
60° 800 45°
45° 1200
30° 15° 0° 15° 30° I(0°)=100cd/klm [cd/klm] C0-C180 C90-C270
156
5,00
7,0
6,5
5,00
9,0
17,5
5,00
9,5
22,0
6,00
1,5
7,5
6,00
1,0
11,5
6,00
11,0
20,0
7,00
2,0
6,0
7,00
3,0
9,5
7,00
12,0
12,5
8,00
11,5
11,0
Information for readers Photometry of SPY 2 – SP2
L1
L2
h
L1 – distance from the wall to the first fixture L2 – distance between fixtures h – height of the ceiling
SP2 – without optics
SP2 1W (140lm) min. 0,5lx
=100%
BZ2 90°
90°
75°
75° 80
60°
60° 160
45°
45° 240 320
30°
30° 15°
I(0°)=352cd/klm C0-C180
400 0°
15°
[cd/klm] C90-C270
SP2 2W (250lm) min. 0,5lx
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
3,0
8,5
2,50
3,5
9,5
2,50
4,0
10,5
3,00
3,0
9,0
3,00
3,5
10,0
3,00
4,0
11,5
3,50
3,5
10,5
3,50
4,0
11,5
3,50
4,5
12,5
4,00
4,0
11,0
4,00
4,5
12,0
4,00
4,5
13,0
4,50
4,0
11,5
4,50
4,5
12,5
4,50
5,0
14,0
5,00
4,0
11,5
5,00
5,0
13,0
5,00
5,5
15,0
6,00
4,0
12,0
6,00
5,5
15,0
6,00
6,0
16,0
7,00
3,5
11,5
7,00
5,5
16,5
7,00
6,5
17,0
8,00
3,0
10,5
8,00
6,0
16,0
8,00
7,0
17,5
SP2 1W (140lm) min. 1lx
SP2 2W (250lm) min. 1lx
SP2 3W (360lm) min. 1lx
h [m]
L1
L2
h [m]
L1
L2
h [m]
L1
L2
2,50
2,0
7,0
2,50
2,5
8,0
2,50
3,0
8,5
3,00
2,0
7,5
3,00
2,5
8,5
3,00
3,0
9,5
3,50
2,5
8,0
3,50
3,0
9,5
3,50
3,5
10,5
4,00
2,5
8,5
4,00
3,0
10,0
4,00
3,5
11,0
4,50
2,0
9,0
4,50
3,0
11,0
4,50
4,0
12,0
5,00
2,0
9,5
5,00
3,5
11,5
5,00
4,0
12,5
6,00
1,5
10,0
SP2 2W (250lm) min. 5lx
157
SP2 3W (360lm) min. 0,5lx
h [m]
6,00
3,0
12,5
6,00
4,0
13,5
7,00
2,5
13,0
7,00
3,5
14,5
8,00
2,0
13,5
8,00
3,5
15,5
SP2 3W (360lm) min. 5lx
h [m]
L1
L2
h [m]
L1
L2
2,50
2,0
5,5
2,50
2,5
6,5
3,00
2,0
5,5
3,00
2,5
6,5
3,50
1,5
5,0
3,50
2,5
7,0
4,00
2,0
7,0
4,50
1,5
6,5
Information for readers Photometry of EDGE R – EDRE12, EDRE18, EDRE24
L1
L2
h
L1 – distance from the wall to the first fixture L2 – distance between fixtures h – height of the ceiling
EDGE R - EDRE12, EDRE18, EDRE24
EDGE R 3W (305lm) min. 0,5lx L1
L2
h [m]
L1
L2
2,5
3,5
10,5
2,5
4,0
10,0
3,0
3,5
12,0
3,0
4,5
11,0
3,5
3,5
12,5
3,5
4,5
11,5
4,0
4,0
13,5
4,0
4,5
12,5
5,0
4,0
15,0
5,0
5,0
13,5
6,0
4,0
16,0
6,0
5,0
14,0
7,0
4,5
17,0
7,0
4,5
14,0
8,0
4,5
18,0
8,0
4,5
14,0
9,0
4,5
19,0
9,0
3,5
14,0
10,0
4,0
19,5
10,0
2,5
13,5
11,0
3,5
20,0
11,0
1,0
12,5
12,0
3,5
20,0
13,0
2,5
20,5
14,0
2,0
21,0
*photometry of EDGE R 12W, 18W, 24W is the same
158
EDGE R 3W (305lm) min. 1lx
h [m]
Information for readers Photometry of EDGE S – EDSE12, EDSE18, EDSE24
L1
L2
h
L1 – distance from the wall to the first fixture L2 – distance between fixtures h – height of the ceiling
EDGE S - EDSE12, EDSE18, EDSE24
EDGE S 3W (305lm) min. 0,5lx L1
L2
h [m]
L1
L2
2,5
3,5
10,5
2,5
4,0
10,0
3,0
3,5
12,0
3,0
4,5
11,0
3,5
3,5
12,5
3,5
4,5
11,5
4,0
4,0
13,5
4,0
4,5
12,5
5,0
4,0
15,0
5,0
5,0
13,5
6,0
4,0
16,0
6,0
5,0
14,0
7,0
4,5
17,0
7,0
4,5
14,0
8,0
4,5
18,0
8,0
4,5
14,0
9,0
4,5
19,0
9,0
3,5
14,0
10,0
4,0
19,5
10,0
2,5
13,5
11,0
3,5
20,0
11,0
1,0
12,5
12,0
3,5
20,0
13,0
2,5
20,5
14,0
2,0
21,0
*photometry of EDGE S 12W, 18W, 24W is the same
159
EDGE S 3W (305lm) min. 1lx
h [m]
Information for readers Photometry of OUTDOOR LED – ODB
h
R'2
R2 R1
p1
R'1
R1 – radius of the illumination for avg. 5lx R1’ – distance from the wall for avg. 5lx R2 – radius of the illumination for avg. 1lx R2’ – distance from the wall for avg. 1lx h – assembly height of the fitting p1 – max light intensity under the luminaire
ODB 3x1W
ODB 3x1W (360lm) min. 1lx and min. 5lx h [m] - assembly height of the fitting
160
p1 [lx] max under the fitting
R1 [m] for min. 5lx
R1’ [m] for min. 5lx
R2 [m] for min. 1lx
R2’ [m] for min. 1lx
2
30
4,2
3,0
6,9
5,5
2,2
25
4,4
3,0
7,1
5,7
2,4
21
4,4
3,1
7,4
5,8
2,6
18
4,4
3,1
7,6
6,0
2,8
15
4,3
3,1
7,8
6,1
3
13
4,1
3,0
8,0
6,2
3,2
11
4,0
3,0
8,4
6,3
3,4
10
3,7
2,9
8,6
6,4
3,6
9
3,4
2,8
8,9
6,5
Information for readers Photometry of TIGER LED – TL
L1
L2
h
L1 – distance from the wall to the first fixture L2 – distance between fixtures h – height of the ceiling
TL – transparent cover
161
TL 3W (380lm) min. 1lx
TL 3W (380lm) min 0,5lx
h [m]
L1
L2
h [m]
L1
L2
2,50
4,00
10,00
2,50
4,00
10,00
3,00
4,00
10,50
3,00
4,50
11,00
3,50
4,00
11,00
3,50
5,00
11,50
4,00
4,00
11,00
4,00
5,00
12,50
4,50
4,50
11,50
4,50
5,50
13,50
5,00
4,50
12,00
5,00
5,50
14,00
6,00
4,50
13,00
6,00
6,00
15,00
7,00
4,50
13,50
7,00
6,00
16,50
8,00
4,50
13,50
8,00
6,00
17,50
Information for readers Photometry of SK-8 – SK8
h
R'2
R2 R1
p1
R'1
R1 – radius of the illumination for avg. 5lx R1’ – distance from the wall for avg. 5lx R2 – radius of the illumination for avg. 1lx R2’ – distance from the wall for avg. 1lx h – assembly height of the fitting p1 – max light intensity under the luminaire
SK-8 3W
SK8 3W (120lm) min. 1lx and min. 5lx h [m] - assembly height of the fitting
162
p1 [lx] max under the fitting
R1 [m] for min. 5lx
R1’ [m] for min. 5lx
R2 [m] for min. 1lx
R2’ [m] for min. 1lx
2
62
2,9
0,8
5,2
2,0
2,2
50
3,0
0,9
5,4
2,0
2,4
41
3,1
0,9
5,5
2,0
2,6
34
3,2
0,9
5,6
1,9
2,8
29
3,2
0,9
5,6
1,9
3
25
3,2
0,9
5,8
1,8
3,2
22
3,3
0,9
6,0
1,8
3,4
20
3,3
0,9
6,0
1,8
3,6
18
3,3
0,9
6,0
1,8
Information for readers Photometry of INFINITY II – IF2BWD, IF2AWD, IF2ACD, IF2ALD
h
R'2
R2 R1
p1
R'1
R1 – radius of the illumination for avg. 5lx R1’ – distance from the wall for avg. 5lx R2 – radius of the illumination for avg. 1lx R2’ – distance from the wall for avg. 1lx h – assembly height of the fitting p1 – max light intensity under the luminaire
IF2BWD - with floor illumination system
IF2BWD 3W (80lm) min. 1lx and min. 5lx h [m] - assembly height of the fitting
R1 [m] for min. 5lx
R1’ [m] for min. 5lx
R2 [m] for min. 1lx
R2’ [m] for min. 1lx
2
13
2,9
0,9
5,7
2,2
2,2
11
2,7
0,9
6,0
2,1
2,4
8,5
2,5
0,9
6,1
1,8
2,6
7,5
2,2
0,8
6,3
1,8
2,8
6,5
1,8
0,7
6,4
1,8
3
5,5
1,1
0,5
6,5
1,8
3,2
4,5
–
–
6,5
1,8
3,4
4,0
–
–
6,6
1,8
3,6
3,5
–
–
6,6
1,9
*photometry of IF2AWD, IF2ACD, IF2ALD is the same like IF2BWD
163
p1 [lx] max under the fitting
Information for readers USED SYMBOLS
The product meets the requirements in accordance with the European Directive
220-240V AC 50-60Hz
The permissible range of AC input voltage
176-275V DC
The permissible range of DC input voltage
24V DC
Ni-Cd
LED
T5 G5
IP65
Light source type – LED
Light source type – fluorescent lamp T5
Protection class – IP65
Safety extra low voltage SELV
Mounting of emergency escape lighting fittings – surface / ceiling
Insulation class I
Mounting of emergency escape lighting fittings – recessed / ceiling
Insulation class II
Mounting of emergency exit signs – recessed / ceiling
Insulation class III
Mounting of emergency exit signs – surface / ceiling
Type of used battery
Viewing distance d=25m d=25m
Current list of products with ENEC is available at www.awex.eu
Adaptation of the fixture for low temperatures up to -25°C
Current list of products with Kitemark is available at www.awex.eu KM 61835 BS-EN
1pc. of universal pictogram is included in each single box, other must be chosen *see pictogram
Photographs and parameters of the products shown in this catalogue are for reference only and cannot be relied upon as a legal offer. Certain parameters of supplied products may differ from the parameters of the products described in this catalogue. The appearance of actual products may slightly differ from the photographs and drawings contained in this catalogue. P.P.H.U AWEX reserves the right to discontinue products shown in this catalogue or to modify their parameter without notice.
164
AWEX SP. Z O.O. SPÓŁKA KOMANDYTOWA Masłomiąca, ul. Długa 39 32-091 Michałowice, Poland tel. +48 12 681 55 00 fax. +48 12 681 55 22 e-mail: export@awex.eu www: awex.eu
Distributor