Comparative Study of G+7 Storey Residential Building in Seismic Zone 5

Page 4

International Journal for Research in Applied Science & Engineering Technology (IJRASET) ISSN: 2321-9653; IC Value: 45.98; SJ Impact Factor: 7.538 Volume 10 Issue VII July 2022- Available at www.ijraset.com The damages are caused by inconsistence seismic response, irregularity in mass and plan, soft storey and floating columns etc. Hence it becomes necessary to evaluate actual seismic performance of building subjected to earthquake forces. Time History analysis gives more realistic seismic behaviour of the building. It gives more accurately seismic responses than response spectrum analysis because of it incorporates material nonlinearity and dynamic nature of earthquake. III. METHODOLOGY & STRUCTURE MODELLING The seismic analysis should be carried out for the buildings that have lack of resistance to earthquake forces. Seismic analysis will consider dynamic effects hence the exact analysis sometimes become complex. However, for simple regular structures equivalent linear static analysis is sufficient one. This type of analysis will be carried out for regular and low rise buildings and this method will give good results for this type of buildings. Dynamic analysis will be carried out for the building as specified by code IS 18932002 (part1). Dynamic analysis will be carried out either by Response spectrum method or site specific Time history method. A. Methodology In the present Study, Analysis of G+7 multi-story building in zone 5 for earth quake force is carried out. Two models were prepared for G+7 multi-story building in ETABS. 1) Model 1: - G+7 Building with Columns 2) Model 2: - G+7 Building with Shear Walls Comparison of above two Model for different two methods are performed in this study. Two Methods are used for the Analysis work in E-tabs Software for Seismic Zone 5 are followings: a) Seismic Co-Efficient Method & b) Response Spectrum Analysis B. Statement of the Project The design data shall be as follows: 1 Utility of buildings 2 No. of Storey 3 Shape of the building 4 No. of Staircases 5 No. of Lifts 6 Types of Walls 7 Geometric details Ground Floor Floor-To-Floor Height 8 Material Details Concrete Grade All steel grades 9 Type of construction

: : : : : :

Residential Building G+7 Rectangular (Symmetrical) One Three AAC Block Wall & RCC Wall

: :

3.60 m 2.95 m

: : :

M20, M25 HYSD reinforcement of Fe 415, Fe 500 R.C.C Framed structure

C. Structural Modelling by E-tabs

©IJRASET: All Rights are Reserved | SJ Impact Factor 7.538 | ISRA Journal Impact Factor 7.894 |

1455


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.
Comparative Study of G+7 Storey Residential Building in Seismic Zone 5 by IJRASET - Issuu